Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
gtSensorsMIB | 1.3.6.1.4.1.7465.20.2.9.1.3 |
This MIB module represents the various sensors that are installed in a system or standalone unit, such as temperature sensors, power supply voltage/current measurements and fan RPM sensors. |
||
gtSensorsNotifications | 1.3.6.1.4.1.7465.20.2.9.1.3.0 | |||
gtSensorsNotifyFanPlugin | 1.3.6.1.4.1.7465.20.2.9.1.3.0.1 |
The gtSensorsNotifyFanPlugin notification indicates that a new fan unit has been plugged-in. |
||
gtSensorsNotifyFanPlugout | 1.3.6.1.4.1.7465.20.2.9.1.3.0.2 |
The gtSensorsNotifyFanPlugout notification indicates that a fan unit has been plugged-out. |
||
gtSensorsNotifyPSUPlugin | 1.3.6.1.4.1.7465.20.2.9.1.3.0.3 |
The gtSensorsNotifyPSUPlugin notification indicates that a new PSU (Power Supply Unit) has been plugged-in. |
||
gtSensorsNotifyPSUPlugout | 1.3.6.1.4.1.7465.20.2.9.1.3.0.4 |
The gtSensorsNotifyPSUPlugout notification indicates that a PSU (Power Supply Unit) has been plugged-out. |
||
gtSensorsNotifyTemperature | 1.3.6.1.4.1.7465.20.2.9.1.3.0.5 |
The gtSensorsNotifyTemperature notification indicates that temperature on GT11 board is above upper limit. |
||
gtSensorsNotifyFanSpeed | 1.3.6.1.4.1.7465.20.2.9.1.3.0.6 |
The gtSensorsNotifyFanSpeed notification indicates that at least one of the fans RPM on fanbay is below lower limit. |
||
gtSensorsNotifyPSUCurrent | 1.3.6.1.4.1.7465.20.2.9.1.3.0.7 |
The gtSensorsNotifyPSUCurrent notification indicates that a PSU (Power Supply Unit) output current is out of range limit. |
||
gtSensorsNotifyPSUVoltage | 1.3.6.1.4.1.7465.20.2.9.1.3.0.8 |
The gtSensorsNotifyPSUVoltage notification indicates that a PSU (Power Supply Unit) output voltage is out of range limit. |
||
gtSensorsNotifyPSUTemperature | 1.3.6.1.4.1.7465.20.2.9.1.3.0.9 |
The gtSensorsNotifyPSUTemperature notification indicates that a PSU (Power Supply Unit) temperature is above upper limit. |
||
gtSensorsNotifyPSUTemperatureClear | 1.3.6.1.4.1.7465.20.2.9.1.3.0.10 |
The gtSensorsNotifyPSUTempHighClear notification indicates that a PSU (Power Supply Unit) temperature has decreased below upper limit. |
||
gtSensorsNotifyBOARDTemperatureClear | 1.3.6.1.4.1.7465.20.2.9.1.3.0.11 |
The gtSensorsNotifyBOARDTempHighClear notification indicates that temperature on GT11 board has decreased below upper limit |
||
gtSensorsNotifyPSUFailure | 1.3.6.1.4.1.7465.20.2.9.1.3.0.12 |
The gtSensorsNotifyPSUFailure notification indicates that a PSU (Power Supply Unit) internal voltage dropped below limit. |
||
gtSensorsNotifyPSUFailureClear | 1.3.6.1.4.1.7465.20.2.9.1.3.0.13 |
The gtSensorsNotifyPSUFailureClear notification indicates that a PSU (Power Supply Unit) internal voltage has increased above lower limit. |
||
gtSensorsObjects | 1.3.6.1.4.1.7465.20.2.9.1.3.1 | |||
gtNumTemps | 1.3.6.1.4.1.7465.20.2.9.1.3.1.1 | unsigned32 | read-only |
The gtNumTemps entity represents the number of temperature sensors within the GT01/GN50 rack unit. The related entries are provided by gtTempsTable. |
gtTempsTable | 1.3.6.1.4.1.7465.20.2.9.1.3.1.2 | no-access |
The gtTempsTable table contains a list of all temperature sensors within the GT01/GN50 rack unit. The number of entries is provided by gtNumTemps. |
|
1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1 | no-access |
The gtTempsEntry table entry represents a temperature sensors within the GT01/GN50 rack unit. The number of entries is provided by gtNumTemps. |
||
gtTemp | 1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1.1 | unsigned32 | no-access |
The gtTemp entity represents the numeric index of a temperature sensors within the GT01/GN50 rack unit. |
gtTempName | 1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1.2 | displaystring | read-only |
The gtTempName entity represents the symbolic name of a temperature sensors within the GT01/GN50 rack unit. |
gtTempValue | 1.3.6.1.4.1.7465.20.2.9.1.3.1.2.1.3 | integer32 | read-only |
The gtTempValue entity represents the measured value of a temperature sensors within the GT01/GN50 rack unit. |
gtNumFans | 1.3.6.1.4.1.7465.20.2.9.1.3.1.3 | unsigned32 | read-only |
The gtNumFans entity represents the number of cooling fans within the GT01/GN50 rack unit. The related entries are provided by gtFansTable. |
gtFansTable | 1.3.6.1.4.1.7465.20.2.9.1.3.1.4 | no-access |
The gtFansTable table contains a list of all cooling fans within the GT01/GN50 rack unit. The number of entries is provided by gtNumFans. |
|
1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1 | no-access |
The gtFansEntry table entry represents an cooling fan within the GT01/GN50 rack unit. The number of entries is provided by gtNumFans. |
||
gtFan | 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.1 | unsigned32 | no-access |
The gtFan entity represents the numeric index of a cooling fan within the GT01/GN50 rack unit. |
gtFanName | 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.2 | displaystring | read-only |
The gtFanName entity represents the symbolic name of a cooling fan within the GT01/GN50 rack unit. |
gtFanControl | 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.3 | unsigned32 | read-only |
The gtFanControl entity represents the RPM setting of a cooling fan within the GT01/GN50 rack unit. |
gtFanSpeed | 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.4 | unsigned32 | read-only |
The gtFanSpeed entity represents the revolutions per minute of a cooling fan within the GT01/GN50 rack unit. |
gtFanUptime | 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.5 | counter32 | read-only |
The gtFanUptime entity represents the current uptime of a cooling fan within the GT01/GN50 rack unit. |
gtFanLifetime | 1.3.6.1.4.1.7465.20.2.9.1.3.1.4.1.6 | counter32 | read-only |
The gtFanLifetime entity represents the accumulated lifetime of a cooling fan within the GT01/GN50 rack unit. |
gtNumPSUs | 1.3.6.1.4.1.7465.20.2.9.1.3.1.5 | unsigned32 | read-only |
The gtNumPSUs entity represents the number of power supply units within the GT01/GN50 rack unit. The related entries are provided by gtPSUsTable. |
gtPSUsTable | 1.3.6.1.4.1.7465.20.2.9.1.3.1.6 | no-access |
The gtPSUsTable table contains a list of all power supply units within the GT01/GN50 rack unit. The number of entries is provided by gtNumPSUs. |
|
1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1 | no-access |
The gtPSUsEntry table entry represents a power supply unit within the GT01/GN50 rack unit. The number of entries is provided by gtNumPSUs. |
||
gtPSU | 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.1 | unsigned32 | no-access |
The gtPSU entity represents the numeric index of a power supply unit within the GT01/GN50 rack unit. |
gtPSUName | 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.2 | displaystring | read-only |
The gtPSUName entity represents the symbolic name of a power supply unit within the GT01/GN50 rack unit. |
gtPSUPower | 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.3 | unsigned32 | read-only |
The gtPSUPower entity represents the maximum output of a power supply unit within the GT01/GN50 rack unit. |
gtPSUCurrent | 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.4 | unsigned32 | read-only |
The gtPSUCurrent entity represents the output current of a power supply unit within the GT01/GN50 rack unit. |
gtPSUVoltageInt | 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.5 | unsigned32 | read-only |
The gtPSUVoltageInt entity represents the internal voltage of a power supply unit within the GT01/GN50 rack unit. |
gtPSUVoltageOR | 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.6 | unsigned32 | read-only |
The gtPSUVoltageOR entity represents the OR voltage drop of a power supply unit within the GT01/GN50 rack unit. |
gtPSUVoltageExt | 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.7 | unsigned32 | read-only |
The gtPSUVoltageExt entity represents the external voltage of a power supply unit within the GT01/GN50 rack unit. |
gtPSUTemperature | 1.3.6.1.4.1.7465.20.2.9.1.3.1.6.1.8 | integer32 | read-only |
The gtPSUTemperature entity represents the temperature of a power supply unit within the GT01/GN50 rack unit. |
gtSensorsConformance | 1.3.6.1.4.1.7465.20.2.9.1.3.2 | |||
gtSensorsCompliances | 1.3.6.1.4.1.7465.20.2.9.1.3.2.1 | |||
gtSensorsMIBCompliance | 1.3.6.1.4.1.7465.20.2.9.1.3.2.1.1 |
The compliance statement for GTSENSORSv2 entities which implement the GTSENSORSv2 MIB. |
||
gtSensorsGroups | 1.3.6.1.4.1.7465.20.2.9.1.3.2.2 | |||
gtSensorsV1Group | 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.1 |
The gtSensorsV1Group group is mandatory only for those GTSENSORSv2 entities which also implement GTSENSORSv1. |
||
gtSensorsSystemGroup | 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.2 |
The gtSensorsSystemGroup group defines GTSENSORSv2 entities which are mandatory. |
||
gtSensorsStatsGroup | 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.3 |
The gtSensorsStatsGroup group defines GTSENSORSv2 entities which provide statistical information. |
||
gtSensorsTrapGroup | 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.4 |
The gtSensorsTrapGroup group defines GTSENSORSv2 trap objects which are mandatory. |
||
gtSensorsSetGroup | 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.5 |
The gtSensorsSetGroup group defines GTSENSORSv2 entities which can be set the manager. |
||
gtSensorsBasicNotificationsGroup | 1.3.6.1.4.1.7465.20.2.9.1.3.2.2.6 |
The gtSensorsBasicNotificationsGroup group defines GTSENSORSv2 notification objects which are mandatory. |