WDMYCLOUDEX4-MIB: View SNMP OID List / Download MIB
VENDOR: WESTERN DIGITAL CORPORATION
Home | MIB: WDMYCLOUDEX4-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
wd | 1.3.6.1.4.1.5127 | |||
productID | 1.3.6.1.4.1.5127.1 | |||
projectID | 1.3.6.1.4.1.5127.1.1 | |||
modelID | 1.3.6.1.4.1.5127.1.1.1 | |||
submodelID | 1.3.6.1.4.1.5127.1.1.1.1 | |||
nasAgent | 1.3.6.1.4.1.5127.1.1.1.1.1 | |||
wdmycloudex4AgentVer | 1.3.6.1.4.1.5127.1.1.1.1.1.1 | displaystring | read-only |
Version information for the agent of SNMP of WDMYCLOUDEX4. |
wdmycloudex4SoftwareVersion | 1.3.6.1.4.1.5127.1.1.1.1.1.2 | displaystring | read-only |
The device software version. |
wdmycloudex4HostName | 1.3.6.1.4.1.5127.1.1.1.1.1.3 | displaystring | read-only |
The device host name. |
wdmycloudex4FTPServer | 1.3.6.1.4.1.5127.1.1.1.1.1.5 | displaystring | read-only |
Ftp Server status. 1 : enable 0 : disable |
wdmycloudex4NetType | 1.3.6.1.4.1.5127.1.1.1.1.1.6 | displaystring | read-only |
The Network type. 0 : Workgroup 1 : Active Directory |
wdmycloudex4Temperature | 1.3.6.1.4.1.5127.1.1.1.1.1.7 | displaystring | read-only |
The temperature of the system. |
wdmycloudex4FanStatus | 1.3.6.1.4.1.5127.1.1.1.1.1.8 | displaystring | read-only |
The status of the fan0 & fan1. |
wdmycloudex4VolumeTable | 1.3.6.1.4.1.5127.1.1.1.1.1.9 | no-access |
A table of active volumes on the NAS device. |
|
1.3.6.1.4.1.5127.1.1.1.1.1.9.1 | no-access |
An entry in the volume table. |
||
wdmycloudex4VolumeNum | 1.3.6.1.4.1.5127.1.1.1.1.1.9.1.1 | integer32 | read-only |
Instance number of the volume entry. |
wdmycloudex4VolumeName | 1.3.6.1.4.1.5127.1.1.1.1.1.9.1.2 | displaystring | read-only |
The name of the volume. |
wdmycloudex4VolumeFsType | 1.3.6.1.4.1.5127.1.1.1.1.1.9.1.3 | displaystring | read-only |
The type of file system of the volume. Example : ext3 or ext4 |
wdmycloudex4VolumeRaidLevel | 1.3.6.1.4.1.5127.1.1.1.1.1.9.1.4 | displaystring | read-only |
The RAID level of the volume. (STANDARD LINEAR RAID0 RAID1 RAID5 RAID10 RAID5+SPARE) |
wdmycloudex4VolumeSize | 1.3.6.1.4.1.5127.1.1.1.1.1.9.1.5 | displaystring | read-only |
The size of the volume in bytes. |
wdmycloudex4VolumeFreeSpace | 1.3.6.1.4.1.5127.1.1.1.1.1.9.1.6 | displaystring | read-only |
Free space on the volume in bytes. |
wdmycloudex4DiskTable | 1.3.6.1.4.1.5127.1.1.1.1.1.10 | no-access |
A table of physical disks attached to the NAS device. |
|
1.3.6.1.4.1.5127.1.1.1.1.1.10.1 | no-access |
An entry in the physical disk table. |
||
wdmycloudex4DiskNum | 1.3.6.1.4.1.5127.1.1.1.1.1.10.1.1 | integer32 | read-only |
Instance number of the disk entry. |
wdmycloudex4DiskVendor | 1.3.6.1.4.1.5127.1.1.1.1.1.10.1.2 | displaystring | read-only |
The vendor of the disk drive. |
wdmycloudex4DiskModel | 1.3.6.1.4.1.5127.1.1.1.1.1.10.1.3 | displaystring | read-only |
The disk drive's model name. |
wdmycloudex4DiskSerialNumber | 1.3.6.1.4.1.5127.1.1.1.1.1.10.1.4 | displaystring | read-only |
The disk drive's serial number. |
wdmycloudex4DiskTemperature | 1.3.6.1.4.1.5127.1.1.1.1.1.10.1.5 | displaystring | read-only |
The centigrade temperature of this disk. |
wdmycloudex4DiskCapacity | 1.3.6.1.4.1.5127.1.1.1.1.1.10.1.6 | displaystring | read-only |
The capacity of the disk in GB. |
wdmycloudex4UPSTable | 1.3.6.1.4.1.5127.1.1.1.1.1.11 | no-access |
A table of UPS attached to the NAS device. |
|
1.3.6.1.4.1.5127.1.1.1.1.1.11.1 | no-access |
An entry in the UPS table. |
||
wdmycloudex4UPSNum | 1.3.6.1.4.1.5127.1.1.1.1.1.11.1.1 | integer32 | read-only |
Instance number of the UPS entry. |
wdmycloudex4UPSMode | 1.3.6.1.4.1.5127.1.1.1.1.1.11.1.2 | displaystring | read-only |
The mode of the UPS |
wdmycloudex4UPSManufacturer | 1.3.6.1.4.1.5127.1.1.1.1.1.11.1.3 | displaystring | read-only |
The manufacturer of the UPS. |
wdmycloudex4UPSProduct | 1.3.6.1.4.1.5127.1.1.1.1.1.11.1.4 | displaystring | read-only |
The product name of the UPS. |
wdmycloudex4UPSBatteryCharge | 1.3.6.1.4.1.5127.1.1.1.1.1.11.1.5 | displaystring | read-only |
The battery charge of the UPS. |
wdmycloudex4UPSStatus | 1.3.6.1.4.1.5127.1.1.1.1.1.11.1.6 | displaystring | read-only |
The status of this UPS. |
notifyEvts | 1.3.6.1.4.1.5127.1.1.1.1.1.200 | |||
notifyPasswdChanged | 1.3.6.1.4.1.5127.1.1.1.1.1.200.1 |
An indication that the Administrator's password has been changed. |
||
notifyFirmwareUpgraded | 1.3.6.1.4.1.5127.1.1.1.1.1.200.2 |
An indication that firmware has been upgraded. |
||
notifyNetworkChanged | 1.3.6.1.4.1.5127.1.1.1.1.1.200.3 |
An indication that the network settings has been changed. |
||
notifyTemperatureExceeded | 1.3.6.1.4.1.5127.1.1.1.1.1.200.4 |
An indication that system temperature has exceeded. |