WBSN-APPLIANCE-MIB: View SNMP OID List / Download MIB
VENDOR: WEBSENSE
Home | MIB: WBSN-APPLIANCE-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
websense | 1.3.6.1.4.1.23365 |
Websense Appliance SNMP |
||
appliance | 1.3.6.1.4.1.23365.10000 | |||
moduleName | 1.3.6.1.4.1.23365.10000.1 | displaystring | read-only |
The name of current module: Appliance Controller, Websense Content Gateway, Websense Web Security, Network Agent, Websense Email Security Gateway |
memUsageFlag | 1.3.6.1.4.1.23365.10000.2 | integer | read-only |
The flag to indicate memory usage exceed |
vmTable | 1.3.6.1.4.1.23365.10000.3 | no-access |
A list of virtual machines. |
|
1.3.6.1.4.1.23365.10000.3.1 | no-access |
A concept row of virtual machine table. |
||
vmStatus | 1.3.6.1.4.1.23365.10000.3.1.1 | integer | read-only |
The status of virtual machine. Enumeration: 'offline': 1, 'online': 0. |
vmName | 1.3.6.1.4.1.23365.10000.3.1.2 | displaystring | read-only |
The name of virtual machine. |
hostname | 1.3.6.1.4.1.23365.10000.4 | |||
hostnameChangeFlag | 1.3.6.1.4.1.23365.10000.4.1 | integer | read-only |
The flag to indicate hostname change. |
prevHostname | 1.3.6.1.4.1.23365.10000.4.2 | displaystring | read-only |
The hostname before changed. |
currHostname | 1.3.6.1.4.1.23365.10000.4.3 | displaystring | read-only |
The current hostname. |
ifaTable | 1.3.6.1.4.1.23365.10000.5 | no-access |
A list of monitoring interface IP addresses. |
|
1.3.6.1.4.1.23365.10000.5.1 | no-access |
A concept row of monitoring interface IP address table. |
||
ifaChangeFlag | 1.3.6.1.4.1.23365.10000.5.1.1 | integer | read-only |
The flag to indicate whether the IP address of monitoring interface has been changed. |
ifaName | 1.3.6.1.4.1.23365.10000.5.1.2 | displaystring | read-only |
The name of monitoring interface. |
ifaPrevAddress | 1.3.6.1.4.1.23365.10000.5.1.3 | displaystring | read-only |
The previous IP address of monitoring interface. |
ifaCurrAddress | 1.3.6.1.4.1.23365.10000.5.1.4 | displaystring | read-only |
The current IP address of monitoring interface. |
ifaSpeed | 1.3.6.1.4.1.23365.10000.5.1.5 | integer | read-only |
The speed of monitoring interface. |
ifaInboundExceedFlag | 1.3.6.1.4.1.23365.10000.5.1.6 | integer | read-only |
The flag to indicate whether the inbound network traffic of monitoring interface exceeds its threhold. |
ifaOutboundExceedFlag | 1.3.6.1.4.1.23365.10000.5.1.7 | integer | read-only |
The flag to indicate whether the outbound network traffic of monitoring interface exceeds its threhold. |
ifaPhysAddress | 1.3.6.1.4.1.23365.10000.5.1.8 | displaystring | read-only |
The physical address of monitoring interface. |
ifaChangeFlagv6 | 1.3.6.1.4.1.23365.10000.5.1.9 | integer | read-only |
The flag to indicate whether the IPv6 address of monitoring interface has been changed. |
ifaPrevAddressv6 | 1.3.6.1.4.1.23365.10000.5.1.10 | displaystring | read-only |
The previous IPv6 address of monitoring interface. |
ifaCurrAddressv6 | 1.3.6.1.4.1.23365.10000.5.1.11 | displaystring | read-only |
The current IPv6 address of monitoring interface. |
raidStatus | 1.3.6.1.4.1.23365.10000.6 | |||
raidErrorFlag | 1.3.6.1.4.1.23365.10000.6.1 | integer | read-only |
The flag is set when disk error is detected. |
dskPhysicalNr | 1.3.6.1.4.1.23365.10000.6.2 | displaystring | read-only |
The number of physical disks in the RAID controller. |
dskCriticalNr | 1.3.6.1.4.1.23365.10000.6.3 | displaystring | read-only |
The number of physical disks in critical state. |
dskFailedNr | 1.3.6.1.4.1.23365.10000.6.4 | displaystring | read-only |
The number of physical disks in failed state. |
dskPhysErrMsg | 1.3.6.1.4.1.23365.10000.6.5 | displaystring | read-only |
The error message to describe the abnormal state of physical disks. |
dskVirtualNr | 1.3.6.1.4.1.23365.10000.6.6 | displaystring | read-only |
The number of virtual drives in the RAID controller. |
dskDegradedNr | 1.3.6.1.4.1.23365.10000.6.7 | displaystring | read-only |
The number of degraded virtual drives. |
dskOfflineNr | 1.3.6.1.4.1.23365.10000.6.8 | displaystring | read-only |
The number of offline virtual drives. |
svcTable | 1.3.6.1.4.1.23365.10000.7 | no-access |
A list of service entries. |
|
1.3.6.1.4.1.23365.10000.7.1 | no-access |
A concept row of service table. |
||
svcStatus | 1.3.6.1.4.1.23365.10000.7.1.1 | integer | read-only |
The status of service. Enumeration: 'down': 1, 'disabled': 4, 'resetting': 3, 'up': 0, 'yellow': 2. |
svcName | 1.3.6.1.4.1.23365.10000.7.1.2 | displaystring | read-only |
The name of service. |
loadAvg | 1.3.6.1.4.1.23365.10000.8 | |||
loadErrorFlag | 1.3.6.1.4.1.23365.10000.8.1 | integer | read-only |
The flag is set when load average limit is met. |
loadName | 1.3.6.1.4.1.23365.10000.8.2 | displaystring | read-only |
The load name. |
loadErrorMessage | 1.3.6.1.4.1.23365.10000.8.3 | displaystring | read-only |
The message to describe current load error. |
wsAlert | 1.3.6.1.4.1.23365.10000.9 | |||
wsAlertMessage | 1.3.6.1.4.1.23365.10000.9.1 | displaystring | read-only |
The detailed message to describe current alert. |
evtInfo | 1.3.6.1.4.1.23365.10000.10 | |||
evtTimestamp | 1.3.6.1.4.1.23365.10000.10.1 | displaystring | read-only |
Timestamp when current event occurred |
evtDir | 1.3.6.1.4.1.23365.10000.10.2 | integer | read-only |
The direction of the event Enumeration: 'deassertion': 1, 'assertion': 0. |
evtSensor | 1.3.6.1.4.1.23365.10000.10.3 | displaystring | read-only |
The name of sensor: Power Supply, Temperature, Fan, Voltage, System ACPI Power State, Event Logging Disabled, Physical Security (Chassis Intrusion), Battery |
evtDesc | 1.3.6.1.4.1.23365.10000.10.4 | displaystring | read-only |
The name of current event |
triggerReading | 1.3.6.1.4.1.23365.10000.10.5 | displaystring | read-only |
The trigger reading of sensor |
triggerThreshold | 1.3.6.1.4.1.23365.10000.10.6 | displaystring | read-only |
The threshold to trigger this event |
errorClear | 1.3.6.1.4.1.23365.10000.10000 | |||
cpuMaxUsageExceedClear | 1.3.6.1.4.1.23365.10000.100000.1000 |
Websense Alert: 'high CPU usage' is cleared |
||
memMaxUsageExceedClear | 1.3.6.1.4.1.23365.10000.100000.1001 |
Websense Alert: 'high memory usage' is cleared |
||
networkMaxBandwidthExceedClear | 1.3.6.1.4.1.23365.10000.100000.1002 |
Websense Alert: 'heavy network traffic on interface' is cleared |
||
diskFreeMinSizeExceedClear | 1.3.6.1.4.1.23365.10000.100000.1003 |
Websense Alert: 'low free disk space' is cleared |
||
swapMinFreeExceedClear | 1.3.6.1.4.1.23365.10000.100000.1004 |
Websense Alert: 'low free swap space' is cleared |
||
systemLoadClear | 1.3.6.1.4.1.23365.10000.100000.1005 |
Websense Alert: 'heavy system load' is cleared |
||
logFileMaxSizeExceedClear | 1.3.6.1.4.1.23365.10000.100000.1006 |
Websense Alert: 'too large log file size' is cleared |
||
logCacheMinFreeExceedClear | 1.3.6.1.4.1.23365.10000.100000.1007 |
Websense Alert: 'low free log cache space' is cleared |
||
moduleDownClear | 1.3.6.1.4.1.23365.10000.100000.1050 |
Websense Alert: 'appliance module down' is cleared |
||
serviceDownClear | 1.3.6.1.4.1.23365.10000.100000.1051 |
Websense Alert: 'appliance service down' is cleared |
||
logServerConnectionLostClear | 1.3.6.1.4.1.23365.10000.100000.1053 |
Websense Alert: 'log server connection lost' is cleared |
||
powerSupplyClear | 1.3.6.1.4.1.23365.10000.100000.2001 |
Websense Alert: 'appliance power supply warning' is cleared |
||
redundancyClear | 1.3.6.1.4.1.23365.10000.100000.2002 |
Websense Alert: 'appliance redundancy warning' is cleared |
||
tempsClear | 1.3.6.1.4.1.23365.10000.100000.2003 |
Websense Alert: 'appliance temperatures warning' is cleared |
||
fansClear | 1.3.6.1.4.1.23365.10000.100000.2004 |
Websense Alert: 'appliance fans warning' is cleared |
||
voltClear | 1.3.6.1.4.1.23365.10000.100000.2005 |
Websense Alert: 'appliance voltages warning' is cleared |
||
logsClear | 1.3.6.1.4.1.23365.10000.100000.2006 |
Websense Alert: 'appliance logs warning' is cleared |
||
memClear | 1.3.6.1.4.1.23365.10000.100000.2007 |
Websense Alert: 'appliance memory warning' is cleared |
||
intrusionClear | 1.3.6.1.4.1.23365.10000.100000.2008 |
Websense Alert: 'appliance chassis intrusion detected' is cleared |
||
batteryClear | 1.3.6.1.4.1.23365.10000.100000.2009 |
Websense Alert: 'appliance battery warning' is cleared |
||
raidClear | 1.3.6.1.4.1.23365.10000.100000.2010 |
Websense Alert: 'appliance RAID controller warning' is cleared |
||
testEvent | 1.3.6.1.4.1.23365.100000.10 |
Websense Alert: this event is for testing use |
||
cpuMaxUsageExceed | 1.3.6.1.4.1.23365.100000.1000 |
Websense Alert: high CPU usage |
||
memMaxUsageExceed | 1.3.6.1.4.1.23365.100000.1001 |
Websense Alert: high memory usage |
||
networkMaxBandwidthExceed | 1.3.6.1.4.1.23365.100000.1002 |
Websense Alert: heavy network traffic on interface |
||
diskFreeMinSizeExceed | 1.3.6.1.4.1.23365.100000.1003 |
Websense Alert: low free disk space |
||
swapMinFreeExceed | 1.3.6.1.4.1.23365.100000.1004 |
Websense Alert: low free swap space |
||
systemLoad | 1.3.6.1.4.1.23365.100000.1005 |
Websense Alert: heavy system load |
||
logFileMaxSizeExceed | 1.3.6.1.4.1.23365.100000.1006 |
Websense Alert: too large log file size |
||
logCacheMinFreeExceed | 1.3.6.1.4.1.23365.100000.1007 |
Websense Alert: low free log cache space |
||
moduleDown | 1.3.6.1.4.1.23365.100000.1050 |
Websense Alert: appliance module down |
||
serviceDown | 1.3.6.1.4.1.23365.100000.1051 |
Websense Alert: appliance service down |
||
backupFailure | 1.3.6.1.4.1.23365.100000.1052 |
Websense Alert: appliance backup failure |
||
logServerConnectionLost | 1.3.6.1.4.1.23365.100000.1053 |
Websense Alert: log server connection lost |
||
hostnameChange | 1.3.6.1.4.1.23365.100000.1061 |
Websense Alert: appliance hostname changed |
||
ipAddressChange | 1.3.6.1.4.1.23365.100000.1062 |
Websense Alert: appliance IP address changed |
||
powerSupply | 1.3.6.1.4.1.23365.100000.2001 |
Websense Alert: appliance power supply warning |
||
redundancy | 1.3.6.1.4.1.23365.100000.2002 |
Websense Alert: appliance redundancy warning |
||
temps | 1.3.6.1.4.1.23365.100000.2003 |
Websense Alert: appliance temperatures warning |
||
fans | 1.3.6.1.4.1.23365.100000.2004 |
Websense Alert: appliance fans warning |
||
volt | 1.3.6.1.4.1.23365.100000.2005 |
Websense Alert: appliance voltages warning |
||
logs | 1.3.6.1.4.1.23365.100000.2006 |
Websense Alert: appliance logs warning |
||
mem | 1.3.6.1.4.1.23365.100000.2007 |
Websense Alert: appliance memory warning |
||
intrusion | 1.3.6.1.4.1.23365.100000.2008 |
Websense Alert: appliance chassis intrusion detected |
||
battery | 1.3.6.1.4.1.23365.100000.2009 |
Websense Alert: appliance battery warning |
||
raid | 1.3.6.1.4.1.23365.100000.2010 |
Websense Alert: appliance RAID controller warning |