TSL-MIB: View SNMP OID List / Download MIB
VENDOR: TELEVISION SYSTEMS LTD
Home | MIB: TSL-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
tslMIB | 1.3.6.1.4.1.6853 | |||
alarm | 1.3.6.1.4.1.6853.2 | |||
alarmIdent | 1.3.6.1.4.1.6853.2.1 | displaystring | read-only |
Equipment alarms description and version |
alarmTable | 1.3.6.1.4.1.6853.2.2 | no-access |
The table of alarm entries |
|
1.3.6.1.4.1.6853.2.2.1 | no-access |
An alarm entry in the table |
||
alarmTableIndex | 1.3.6.1.4.1.6853.2.2.1.1 | integer | read-only |
The index into the table |
alarmType | 1.3.6.1.4.1.6853.2.2.1.2 | integer | read-only |
Alarm type Enumeration: 'psuFail': 4, 'currentAlarm': 5, 'internal': 1, 'gpi': 2, 'outputFail': 3. |
alarmIndex | 1.3.6.1.4.1.6853.2.2.1.3 | integer | read-only |
Alarm type number |
alarmText | 1.3.6.1.4.1.6853.2.2.1.4 | displaystring | read-write |
Alarm description |
alarmState | 1.3.6.1.4.1.6853.2.2.1.5 | integer | read-only |
Alarm state Enumeration: 'active': 2, 'inactive': 1. |
alarmPolarity | 1.3.6.1.4.1.6853.2.2.1.6 | integer | read-write |
Alarm active polarity (notApplicable for non-gpi alarms) Enumeration: 'normallyOpen': 2, 'notApplicable': 1, 'normallyClosed': 3. |
alarmData | 1.3.6.1.4.1.6853.2.2.1.7 | opaque | read-only |
Additional alarm data of variable length, according to alarm type. |
alarmTotal | 1.3.6.1.4.1.6853.2.3 | integer | read-only |
The total number of alarms in the table |
alarmLocation | 1.3.6.1.4.1.6853.2.4 | displaystring | read-write |
The physical location of the equipment generating the alarm |
alarmEqptTemp | 1.3.6.1.4.1.6853.2.5 | integer | read-only |
Equipment temperature (in degrees Centigrade) |
alarmEqptTempHi | 1.3.6.1.4.1.6853.2.6 | integer | read-write |
Equipment temperature alarm point (degrees Centigrade) |
mdu12 | 1.3.6.1.4.1.6853.3 | |||
mdu12Ident | 1.3.6.1.4.1.6853.3.1 | displaystring | read-only |
Equipment description and version |
mduPowerOn | 1.3.6.1.4.1.6853.3.2 | integer | read-write |
MDU power-on output sequence Enumeration: 'simultaneous': 1, 'sequential': 2, 'delayed': 3. |
mduSeqDelay | 1.3.6.1.4.1.6853.3.3 | integer | read-write |
Sequential mode delay between outputs |
mduOutputTable | 1.3.6.1.4.1.6853.3.4 | no-access |
Table of output controls |
|
1.3.6.1.4.1.6853.3.4.1 | no-access |
An entry in the output table |
||
mduOutputIndex | 1.3.6.1.4.1.6853.3.4.1.1 | integer | read-only |
Output number |
mduOutputState | 1.3.6.1.4.1.6853.3.4.1.2 | integer | read-write |
MDU Output status Enumeration: 'locked-Off': 3, 'on': 2, 'off': 1, 'locked-On': 4. |
mduOutputDelay | 1.3.6.1.4.1.6853.3.4.1.3 | integer | read-write |
Output on delay from power on (Delay mode only) |
mduOutputlowerCurrent | 1.3.6.1.4.1.6853.3.4.1.4 | integer | read-write |
Lower current limit for output |
mduOutputupperCurrent | 1.3.6.1.4.1.6853.3.4.1.5 | integer | read-write |
Upper current limit for output |
mduOutputCurrent | 1.3.6.1.4.1.6853.3.4.1.6 | integer | read-only |
Output current |
mduOutputpowerFactor | 1.3.6.1.4.1.6853.3.4.1.7 | integer | read-only |
Output power factor |
mduOutputVA | 1.3.6.1.4.1.6853.3.4.1.8 | integer | read-only |
Output apparent power |
mduOutputWatts | 1.3.6.1.4.1.6853.3.4.1.9 | integer | read-only |
Output real power |
mduOutputCal | 1.3.6.1.4.1.6853.3.4.1.10 | integer | read-write |
Output current measure calibration data |
mduPowerStatus | 1.3.6.1.4.1.6853.3.5 | integer | read-only |
Status of MDU power inlets Enumeration: 'allOk': 4, 'input1OK': 2, 'input2OK': 3, 'totalLoss': 1. |
mduVoltageCal | 1.3.6.1.4.1.6853.3.6 | integer | read-write |
Voltage measure calibration data |
mduVoltage | 1.3.6.1.4.1.6853.3.7 | integer | read-only |
Voltage measurement |
mduVoltageFloor | 1.3.6.1.4.1.6853.3.8 | integer | read-write |
Voltage lower limit |
mduVoltageLimit | 1.3.6.1.4.1.6853.3.9 | integer | read-write |
Voltage upper limit |
mduTotalCurrent | 1.3.6.1.4.1.6853.3.10 | integer | read-write |
Total current measurement |
mduCurrentLimit | 1.3.6.1.4.1.6853.3.11 | integer | read-write |
Current total limit |
mduAuxRly1 | 1.3.6.1.4.1.6853.3.12 | integer | read-write |
Auxiliary Relay 1 state Enumeration: 'on': 2, 'off': 1. |
mduAuxRly2 | 1.3.6.1.4.1.6853.3.13 | integer | read-write |
Auxiliary Relay 2 state Enumeration: 'on': 2, 'off': 1. |
alarmTrap | 1.3.6.1.4.1.68530.4 |
An entry in the alarm table has changed state |
||
alarmEqptTempHiTrap | 1.3.6.1.4.1.68530.5 |
The equipment temperature has exceeded the maximum allowed |
||
alarmEqptTempOkTrap | 1.3.6.1.4.1.68530.6 |
The equipment temperature is now within limits |
||
mduPowerStatusTrap | 1.3.6.1.4.1.68530.7 |
The power input to the MDU has changed state |
||
mduVoltageStatusTrap | 1.3.6.1.4.1.68530.8 |
The voltage to the MDU has traversed a limit |
||
mduTotalCurrentStatusTrap | 1.3.6.1.4.1.68530.9 |
The total current through the MDU has traversed a limit |