Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
     tnSyncEMibModule 1.3.6.1.4.1.7483.1.1.2.2.4.6
Synchronous Ethernet MIB attributes.
 tnSyncEConf 1.3.6.1.4.1.7483.2.2.4.8.1
     tnSyncEGroups 1.3.6.1.4.1.7483.2.2.4.8.1.1
         tnSyncEGroup 1.3.6.1.4.1.7483.2.2.4.8.1.1.1
         tnSyncELineRefGroup 1.3.6.1.4.1.7483.2.2.4.8.1.1.2
         tnSyncEControlGroup 1.3.6.1.4.1.7483.2.2.4.8.1.1.3
         tnSyncEPortGroup 1.3.6.1.4.1.7483.2.2.4.8.1.1.4
         tnSyncEStationClockGroup 1.3.6.1.4.1.7483.2.2.4.8.1.1.5
         tnSyncEBITSPortGroup 1.3.6.1.4.1.7483.2.2.4.8.1.1.6
     tnSyncECompliances 1.3.6.1.4.1.7483.2.2.4.8.1.2
         tnSyncECompliance 1.3.6.1.4.1.7483.2.2.4.8.1.2.1
 tnSyncEObjs 1.3.6.1.4.1.7483.2.2.4.8.2
     tnSyncEBasics 1.3.6.1.4.1.7483.2.2.4.8.2.1
         tnSyncETable 1.3.6.1.4.1.7483.2.2.4.8.2.1.1 no-access
Table of Sync-E attributes.
             tnSyncEEntry 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1 no-access
                 tnSyncESyncMsg 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.1 truthvalue read-only
Determines if the timing reference selection for system timing uses sync status messaging (SSM Qualities).
                 tnSyncEActiveRef 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.2 integer read-only
The ID of the association line reference. Enumeration: 'none': 1, 'lineRef3': 5, 'lineRef2': 4, 'lineRef1': 3, 'lineRef0': 2, 'lineRef5': 7, 'lineRef4': 6.
                 tnSyncEWTR 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.3 unsigned32 read-only
The system timing WTR. Current configurable range: 0 to 12, and 999999.
                 tnSyncESwCmdLineRef 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.4 unsigned32 read-only
The third byte represents the switch command: 1 - nocmd 2 - clear 3 - lockout 4 - forceswitch 5 - mannual 6 - auto 7 - clearlockout. The last byte represents the line reference switch to: 0 - internal 1 - lineref0 2 - lineref1 3 - lineref2 4 - lineref3 5 - lineref4 6 - lineref5.
                 tnSyncEClkModState 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.5 integer read-only
The Sync-E clock mode state. Enumeration: 'unknown': 1, 'autonomousFreeRunning': 4, 'autonomousHoldOver': 3, 'locked': 2, 'forcedFreeRunning': 5.
                 tnSyncESystemQL 1.3.6.1.4.1.7483.2.2.4.8.2.1.1.1.6 integer32 read-only
The value of the system quality level (SSM), shown in following: 31 - not applicable When the NE is in SDH mode: 0 - quality unknown 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU. When the NE is in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 20 - PNO.
         tnSyncELineRefTable 1.3.6.1.4.1.7483.2.2.4.8.2.1.2 no-access
Table of VTS map.
             tnSyncELineRefEntry 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1 no-access
                 tnSyncELineRefIndex 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.1 unsigned32 no-access
The ifIndex of the line reference table.
                 tnSyncELineRefAssignedPort 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.2 integer read-only
The assigned port for the line reference. Enumeration: 'c3': 6, 'c4': 7, 'c2': 5, 'c7': 10, 'm4': 37, 'c19': 22, 'c18': 21, 'm1': 34, 'c5': 8, 'm3': 36, 'm2': 35, 'c13': 16, 'c12': 15, 'c11': 14, 'c10': 13, 'c17': 20, 'c16': 19, 'c15': 18, 'c14': 17, 'none': 1, 'c9': 12, 'c8': 11, 'x2': 29, 'x3': 30, 'c1': 4, 'x1': 28, 'x6': 33, 'c6': 9, 'x4': 31, 'x5': 32, 'c22': 25, 'c23': 26, 'c20': 23, 'c21': 24, 'c24': 27, 'l2': 3, 'l1': 2.
                 tnSyncELineRefPriority 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.3 unsigned32 read-only
Line reference priority. Current configurable range: 0 to 8.
                 tnSyncELineRefAdminState 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.4 integer read-only
The administrative state of the line reference. Enumeration: 'down': 2, 'up': 1.
                 tnSyncELineRefOperState 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.5 integer read-only
The operating state of the line reference. Enumeration: 'down': 2, 'up': 1.
                 tnSyncELineLockOut 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.6 truthvalue read-only
If lock out line reference or not.
                 tnSyncELineRefState 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.7 integer read-only
The Sync-E line reference state. Enumeration: 'notAssigned': 1, 'wtr': 4, 'normal': 2, 'signalFailure': 3.
                 tnSyncELineRefSwState 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.8 integer read-only
The Sync-E line reference switch state. Enumeration: 'forced': 2, 'nocmd': 1, 'lockout': 4, 'wtr': 5, 'mansw': 3.
                 tnSyncELineRefIncSSMMsg 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.9 integer32 read-only
This object indicates the current value of incoming QL on that port. 30 - unstable 31 - not applicable When the NE works in SDH mode: 0 - Unknown 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU When the NE works in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 20 - PNO It's applicable only to the timing port with SSM capabilities.
                 tnSyncELineRefIncSSMStatus 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.10 integer32 read-only
This object indicates the current status of incoming QL on that port. 0: Valid 1: Invalid 2: Not Supported 3: Not Applicable It's applicable only to the timing port with SSM capabilities.
                 tnSyncELineRefIncSSMSupp 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.11 integer read-only
Enable or disable the line reference incoming QL processing. Enumeration: 'enable': 1, 'disable': 2.
                 tnSyncELineRefProvQL 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.12 integer32 read-only
Manually provisioned incoming SSM value for the line reference. The value can be: 0 - AUTO When the NE is in SDH mode: 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU When the NE works in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 20 - PNO Note: The parameter can be provisioned only when SyncELineRefIncSSMSupp is enabled.
                 tnSyncELineRefAssociatedPort 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.13 interfaceindexorzero read-only
The associated physical port of the line reference. This parameter replaces tnSyncELineRefAssignedPort in order to support assigning a line reference to a port in other slots.
                 tnSyncELineRefPriorityOfStationClock 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.14 unsigned32 read-only
Line reference priority for the output station clock. Current configurable range: 0 to 8.
                 tnSyncELineRefLockOutOfStationClock 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.15 truthvalue read-only
If lock out the line reference or not for the output station clock.
                 tnSyncELineRefSwStateOfStationClock 1.3.6.1.4.1.7483.2.2.4.8.2.1.2.1.16 integer read-only
The Sync-E line reference switch state of the output station clock. Enumeration: 'forced': 2, 'nocmd': 1, 'lockout': 4, 'wtr': 5, 'mansw': 3.
         tnSyncEControlTable 1.3.6.1.4.1.7483.2.2.4.8.2.1.3 no-access
Table of Sync-E Control attributes.
             tnSyncEControlEntry 1.3.6.1.4.1.7483.2.2.4.8.2.1.3.1 no-access
                 tnSyncEControlEECEnable 1.3.6.1.4.1.7483.2.2.4.8.2.1.3.1.1 integer read-only
enable - The Synchronous Ethernet is supported for the pack and the synchronization attributes can be configured. disable - The Synchronous Ethernet is not supported for the pack and the synchronization attributes can not be configured. Enumeration: 'enable': 1, 'disable': 2.
         tnSyncEPortTable 1.3.6.1.4.1.7483.2.2.4.8.2.1.4 no-access
Table of Sync-E Port attributes.
             tnSyncEPortEntry 1.3.6.1.4.1.7483.2.2.4.8.2.1.4.1 no-access
                 tnSyncEOprMode 1.3.6.1.4.1.7483.2.2.4.8.2.1.4.1.1 integer read-only
The port Synchronous Ethernet Operation Mode. When the port is in SYNC mode, recovered clock of its input signal can be selected as a reference clock to the system clock. When the port is in NON-SYNC mode, the recovered clock of its input signal shall not be a candidate to system timing references. Enumeration: 'non-sync': 2, 'sync': 1.
                 tnSyncEOutgoingForceSsmTrans 1.3.6.1.4.1.7483.2.2.4.8.2.1.4.1.2 integer read-only
The port SSM/Quality Level Transmission value. The value can be: In SDH mode - act, prc, ssua, ssub, sec, dnu, none; In sonet mode - act, stu, prs, st2, sts3e, st3, dus, none. Enumeration: 'none': 12, 'ssua': 3, 'prs': 8, 'prc': 2, 'ssub': 4, 'act': 1, 'sts3e': 10, 'dn': 6, 'st': 7, 'sec': 5, 'st2': 9, 'st3': 11, 'dus': 13.
         tnSyncEStationClockTable 1.3.6.1.4.1.7483.2.2.4.8.2.1.5 no-access
Table of Sync-E station clock attributes.
             tnSyncEStationClockEntry 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1 no-access
                 tnSyncEStationClockSyncMsg 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.1 truthvalue read-only
Determines if the timing reference selection for station clock timing uses sync status messaging (SSM Qualities).
                 tnSyncEStationClockActiveRef 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.2 integer read-only
The ID of the association line reference. Enumeration: 'none': 1, 'lineRef3': 5, 'lineRef2': 4, 'lineRef1': 3, 'lineRef0': 2, 'lineRef5': 7, 'lineRef4': 6.
                 tnSyncEStationClockWTR 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.3 unsigned32 read-only
The station clock timing WTR. Current configurable range: 0 to 12, and 999999.
                 tnSyncEStationClockSwCmdLineRef 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.4 unsigned32 read-only
The third byte represents the switch command: 1 - nocmd 2 - clear 3 - lockout 4 - forceswitch 5 - mannual 6 - auto 7 - clearlockout. The last byte represents the line reference switch to: 0 - internal 1 - lineref0 2 - lineref1 3 - lineref2 4 - lineref3 5 - lineref4 6 - lineref5.
                 tnSyncEStationClockSystemQL 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.5 integer32 read-only
The value of the system quality level (SSM) for the output timing clock, shown in following: 31 - not applicable When the NE is in SDH mode: 0 - quality unknown 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU. When the NE is in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 20 - PNO.
                 tnSyncEStationClockQLThreshold 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.6 integer32 read-only
Specifies the threshold value for the quality level i.e., SSM value for squelching the output towards timing output. If the quality value of the current selected signal for the output is below the threshold value, the output will be squelched. The squelching can be disabled by means of using the value DNU or DUS. When the NE is in SDH mode: 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU. When the NE is in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS. Default value: SEC - for node working in SDH mode ST3 - for node working in SONET mode
                 tnSyncEStationClockOutSel 1.3.6.1.4.1.7483.2.2.4.8.2.1.5.1.7 integer read-only
Specifies which signal is selected for the output station clock: OUTTIM - Output is selected from output timing selection process SETG - Output is selected from system internal timing The ID of the association line reference. Enumeration: 'outtim': 1, 'setg': 2.
         tnSyncEBITSPortTable 1.3.6.1.4.1.7483.2.2.4.8.2.1.6 no-access
Table of BITS port attributes.
             tnSyncEBITSPortEntry 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1 no-access
                 tnSyncEBITSPortDirection 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.1 integer read-only
Indicate the direction of the BITS port. Enumeration: 'input': 1, 'output': 2.
                 tnSyncEBITSPortSignalType 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.2 integer32 read-only
Specify the signal type for the BITS interface: 0 - 2MHz 1 - unframed E1 2 - framed E1 without SSM 3 - framed E1 with SSM 4 - DS1 SF 5 - DS1 ESF. In SDH mode, 2MHz and E1 signal types are valid and 2MHz is the default value. In SONET mode, only the DS1 signal types are valid and DS1 SF is the default value.
                 tnSyncEBITSPortSaBit 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.3 integer read-only
Specifies the Sa bit location used to carry the SSM information. This parameter is only applicable when tnSyncEBITSPortSignalType = 3 (framed E1 with SSM) Enumeration: 'sa8': 5, 'sa7': 4, 'sa6': 3, 'sa5': 2, 'sa4': 1.
                 tnSyncEBITSPortOutputSSMTrans 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.4 integer read-only
The port SSM/Quality Level Transmission value. The value can be: In SDH mode - act, prc, ssua, ssub, sec, dnu, none; In sonet mode - act, stu, prs, st2, sts3e, st3, dus, none. Restriction: The parameter is only applicable when tnSyncEBITSPortDirection = output and tnSyncEBITSPortSignalType = 3 (framed E1 with SSM)or 5 (DS1 ESF). Enumeration: 'none': 12, 'ssua': 3, 'prs': 8, 'prc': 2, 'ssub': 4, 'act': 1, 'sts3e': 10, 'dn': 6, 'st': 7, 'sec': 5, 'st2': 9, 'st3': 11, 'dus': 13.
                 tnSyncEBITSPortOutputAISMode 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.5 integer read-only
Specifies which signal is inserted for the timing output port if the output signal is squelched. The parameter is only applicable for output port types supporting SSM. AISMODE - AIS signal is inserted. QLMODE - DUS is inserted as SSM; output is squelched. Restriction: The parameter is only applicable when tnSyncEBITSPortDirection = output and tnSyncEBITSPortSignalType = 3 (framed E1 with SSM) or 5 (DS1 ESF). Enumeration: 'qlmode': 2, 'aismode': 1.
                 tnSyncEBITSPortLineImpedance 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.6 integer read-only
Nominal line impedance. When in SDH mode, imp75ohms or imp120ohms could be used and the default is imp120ohms. When in ONET mode, imp100ohms could be used and the default is imp100ohms. Enumeration: 'imp75ohms': 1, 'imp100ohms': 3, 'imp120ohms': 2.
                 tnSyncEBITSPortLineCode 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.7 integer read-only
Line code. This attribute is applicable when tnSyncEBITSPortSignalType is DS1 SF or DS1 ESF. Enumeration: 'ami': 2, 'b8zs': 1.
                 tnSyncEBITSPortLbo 1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.8 integer read-only
Line equalization value for the BITS output port, taking one of the following values: - lbo: no compensation - lbo1: 0 to 133 feet - lbo2: 133 to 266 feet - lbo3: 267 to 399 feet - lbo4: 400 to 533 feet - lbo5: 534 to 655 feet This attribute is applicable when tnSyncEBITSPortSignalType is DS1 SF or DS1 ESF. Enumeration: 'lbo3': 4, 'lbo2': 3, 'lbo1': 2, 'lbo5': 6, 'lbo4': 5, 'lbo': 1.