TRIPPLITE-MIB: View SNMP OID List / Download MIB

VENDOR: TRIPP LITE


 Home MIB: TRIPPLITE-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 tripplite 1.3.6.1.4.1.850
This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software.
         trippUPS 1.3.6.1.4.1.850.1
             tlV11TrapsPrefix 1.3.6.1.4.1.850.1.0
                 tlV11upsCritical 1.3.6.1.4.1.850.1.0.100
UPS Critical Alarm.
                 tlV11upsWarning 1.3.6.1.4.1.850.1.0.101
UPS Warning.
                 tlV11upsInformation 1.3.6.1.4.1.850.1.0.102
UPS Information.
                 tlV11upsAlarmCleared 1.3.6.1.4.1.850.1.0.103
UPS Alarm Cleared.
                 tlV11upsAgentStarted 1.3.6.1.4.1.850.1.0.104
Agent started.
                 tlV11upsAgentStopped 1.3.6.1.4.1.850.1.0.105
Agent stopped.
             trippUpsReceptacles 1.3.6.1.4.1.850.1.1
                 upsReceptaclesNumReceptacles 1.3.6.1.4.1.850.1.1.1 nonnegativeinteger read-only
The number of available receptacles in this device. This variable indicates the number of rows in the receptacle table.
                 upsReceptacleTable 1.3.6.1.4.1.850.1.1.2 no-access
A list of receptacle table entries. The number of entries is given by the value of upsReceptaclesNumReceptacles.
                     upsReceptacleEntry 1.3.6.1.4.1.850.1.1.2.1 no-access
An entry containing information applicable to a particular receptacle.
                         upsReceptacleIndex 1.3.6.1.4.1.850.1.1.2.1.1 positiveinteger read-only
The receptacle identifier.
                         upsReceptacleType 1.3.6.1.4.1.850.1.1.2.1.2 integer read-only
The type of receptacle. Enumeration: 'surgeOnly': 1, 'controllableBatteryProtected': 3, 'batteryProtected': 2.
                         upsReceptacleStatus 1.3.6.1.4.1.850.1.1.2.1.3 integer read-only
The status of receptacle. Enumeration: 'on': 1, 'off': 2, 'unknown': 3.
                         upsReceptacleControl 1.3.6.1.4.1.850.1.1.2.1.4 integer read-write
Setting this object to 'on' will turn on the receptacle. Setting this object to 'off' will turn off the receptacle. Setting this object to 'cycle' will turn off and then turn on the receptacle. This action will only take place if the receptacle is controllable (upsReceptacleType = controllableBatteryProtected(3)). Enumeration: 'on': 1, 'off': 2, 'cycle': 3.
             trippUpsTrapInfo 1.3.6.1.4.1.850.1.2
                 upsTrapCode 1.3.6.1.4.1.850.1.2.1 integer read-only
A numeric code identifiying the condition that caused the trap to be sent. If the trap number is 104 (upsAgentStarted) or 105 (upsAgentStopped), this code will indicate whether the SNMP agent is software (1) or hardware (2).
                 upsTrapDescription 1.3.6.1.4.1.850.1.2.2 displaystring read-only
The description of the trap.
             trippUpsEnvironment 1.3.6.1.4.1.850.1.3
                 upsEnvTemperature 1.3.6.1.4.1.850.1.3.1 integer32 read-only
The ambient temperature of the EnviroSense unit (1/10 Deg C).
                 upsEnvHumidity 1.3.6.1.4.1.850.1.3.2 integer read-only
The ambient humidity of the EnviroSense unit (% Humidity).
             trippUpsContacts 1.3.6.1.4.1.850.1.4
                 upsContactTable 1.3.6.1.4.1.850.1.4.1 no-access
A table of contacts attached to the EnviroSense unit.
                     upsContactEntry 1.3.6.1.4.1.850.1.4.1.1 no-access
An entry containing information applicable to a particular contact.
                         upsContactIndex 1.3.6.1.4.1.850.1.4.1.1.1 positiveinteger read-only
The contact identifier.
                         upsContactName 1.3.6.1.4.1.850.1.4.1.1.2 displaystring read-write
The contact name.
                         upsContactStatus 1.3.6.1.4.1.850.1.4.1.1.3 integer read-only
The current status of the contact. Enumeration: 'unknown': 0, 'alarm': 2, 'normal': 1.
                         upsContactConfig 1.3.6.1.4.1.850.1.4.1.1.4 integer read-write
The default configuration of the contact. Enumeration: 'normallyOpen': 1, 'normallyClosed': 0.
         tlEnumerations 1.3.6.1.4.1.850.2
             tlOperatingSystems 1.3.6.1.4.1.850.2.1
                 hpux9 1.3.6.1.4.1.850.2.1.1
                 sunos4 1.3.6.1.4.1.850.2.1.2
                 solaris 1.3.6.1.4.1.850.2.1.3
                 osf 1.3.6.1.4.1.850.2.1.4
                 ultrix 1.3.6.1.4.1.850.2.1.5
                 hpux10 1.3.6.1.4.1.850.2.1.6
                 netbsd1 1.3.6.1.4.1.850.2.1.7
                 freebsd 1.3.6.1.4.1.850.2.1.8
                 irix 1.3.6.1.4.1.850.2.1.9
                 linux 1.3.6.1.4.1.850.2.1.10
                 bsdi 1.3.6.1.4.1.850.2.1.11
                 openbsd 1.3.6.1.4.1.850.2.1.12
                 win32 1.3.6.1.4.1.850.2.1.13
                 hpux11 1.3.6.1.4.1.850.2.1.14
                 win9x 1.3.6.1.4.1.850.2.1.50
                 winnt 1.3.6.1.4.1.850.2.1.51
                 solspark 1.3.6.1.4.1.850.2.1.52
                 solintel 1.3.6.1.4.1.850.2.1.53
                 aix 1.3.6.1.4.1.850.2.1.54
                 sco 1.3.6.1.4.1.850.2.1.55
                 osx 1.3.6.1.4.1.850.2.1.56
                 unknown 1.3.6.1.4.1.850.2.1.255
         tlConformance 1.3.6.1.4.1.850.20
               tlCompliances 1.3.6.1.4.1.850.20.1
               tlGroups 1.3.6.1.4.1.850.20.2
                   tlSubsetGroups 1.3.6.1.4.1.850.20.2.1
                   tlBasicGroups 1.3.6.1.4.1.850.20.2.2
                   tlFullGroups 1.3.6.1.4.1.850.20.2.3
                       tlUpsFullGroups 1.3.6.1.4.1.850.20.2.3.100
                               tlUpsFullIdentGroup 1.3.6.1.4.1.850.20.2.3.100.1
The tlUpsFullIdentGroup defines objects which are common to the Ident group of fully compliant Tripplite UPS's
                               tlUpsFullBatteryGroup 1.3.6.1.4.1.850.20.2.3.100.2
The tlUpsFullBatteryGroup defines objects which are common to the Battery group of fully compliant Tripplite UPS's
                               tlUpsFullAlarmGroup 1.3.6.1.4.1.850.20.2.3.100.6
                                   tlUpsFullAlarmObjsGroup 1.3.6.1.4.1.850.20.2.3.100.6.1
The tlUpsFullAlarmObjsGroup defines objects which are common to the Alarm group of fully compliant Tripplite UPS's
                               tlUpsFullTestGroup 1.3.6.1.4.1.850.20.2.3.100.7
The tlUpsFullTestGroup defines objects which are common to the Test group of fully compliant Tripplite UPS's
                               tlUpsFullControlGroup 1.3.6.1.4.1.850.20.2.3.100.8
The tlUpsFullControlGroup defines objects which are common to the Control group of fully compliant Tripplite UPS's
                               tlUpsFullConfigGroup 1.3.6.1.4.1.850.20.2.3.100.9
The tlUpsFullConfigGroup defines objects which are common to the Config group of fully compliant Tripplite UPS's
                               tlUpsFullOutletGroup 1.3.6.1.4.1.850.20.2.3.100.10
The tlUpsFullOutletGroup defines objects which are common to the Outlet group of fully compliant Tripplite UPS's
                   tlV11Groups 1.3.6.1.4.1.850.20.2.4
                       tlDeprecatedV11Group 1.3.6.1.4.1.850.20.2.4.1
The tlDeprecatedV11Group defines objects which were used by Sinetica SNMP cards on Tripplite UPSs and PowerAlert version 11. These objects are currently only used when tlEngineLegacySNMPSupport == true.
                       tlDeprecatedV11NotificationsGroup 1.3.6.1.4.1.850.20.2.4.2
The tlDeprecatedV11NotificationsGroup defines PowerAlert version 11 notifications. These notifications are being deprecated, but may still be used when tlEngineLegacySNMPSupport = true.
                       tlObsoleteV11Group 1.3.6.1.4.1.850.20.2.4.3
The tlObsoleteV11Group defines objects which were used by Sinetica SNMP cards on Tripplite UPSs. Most of these objects are obsolete.
         tlPowerAlert 1.3.6.1.4.1.850.90
               tlPASystem 1.3.6.1.4.1.850.90.1
                   tlPAContacts 1.3.6.1.4.1.850.90.1.1
                       tlPAEmailContacts 1.3.6.1.4.1.850.90.1.1.1
                           tlPANumberOfEmailContacts 1.3.6.1.4.1.850.90.1.1.1.1 nonnegativeinteger read-only
The number email contacts currently defined.
                           tlPAEmailContactsTable 1.3.6.1.4.1.850.90.1.1.1.2 no-access
A list email contact entries. The number of entries is given by the value of tlPANumberOfEmailContacts.
                               tlPAEmailContactEntry 1.3.6.1.4.1.850.90.1.1.1.2.1 no-access
An entry containing email contacts information.
                                   tlPAEmailContactIndex 1.3.6.1.4.1.850.90.1.1.1.2.1.1 positiveinteger read-only
This is the index number of the email contact.
                                   tlPAEmailContactRowStatus 1.3.6.1.4.1.850.90.1.1.1.2.1.2 rowstatus read-write
The row status for the tlPAEmailContactTable row
                                   tlPAEmailContactName 1.3.6.1.4.1.850.90.1.1.1.2.1.3 displaystring read-write
The name of the email contact.
                                   tlPAEmailContactAddress 1.3.6.1.4.1.850.90.1.1.1.2.1.4 displaystring read-write
The address of the email contact.
                       tlPASnmpContacts 1.3.6.1.4.1.850.90.1.1.2
                           tlPANumberOfSnmpContacts 1.3.6.1.4.1.850.90.1.1.2.1 nonnegativeinteger read-only
The number SNMP contacts currently defined.
                           tlPASnmpContactsTable 1.3.6.1.4.1.850.90.1.1.2.2 no-access
A list SNMP contact entries. The number of entries is given by the value of tlPANumberOfSnmpContacts.
                               tlPASnmpContactEntry 1.3.6.1.4.1.850.90.1.1.2.2.1 no-access
An entry containing SNMP contacts information.
                                   tlPASnmpContactIndex 1.3.6.1.4.1.850.90.1.1.2.2.1.1 positiveinteger read-only
This is the index number of this SNMP contact.
                                   tlPASnmpContactRowStatus 1.3.6.1.4.1.850.90.1.1.2.2.1.2 rowstatus read-write
The row status for the tlPASnmpContactTable row
                                   tlPASnmpContactName 1.3.6.1.4.1.850.90.1.1.2.2.1.3 displaystring read-write
The name of the SNMP contact.
                                   tlPASnmpContactIpAddress 1.3.6.1.4.1.850.90.1.1.2.2.1.4 displaystring read-write
The IP address of the SNMP contact.
                                   tlPASnmpContactPort 1.3.6.1.4.1.850.90.1.1.2.2.1.5 positiveinteger read-write
The port of the SNMP contact.
                                   tlPASnmpContactSnmpVersion 1.3.6.1.4.1.850.90.1.1.2.2.1.6 integer read-write
The SNMP contact version to use for sending traps. Enumeration: 'snmpv2c': 2, 'snmpv1': 1, 'snmpv3': 3.
                                   tlPASnmpContactSecurityName 1.3.6.1.4.1.850.90.1.1.2.2.1.7 displaystring read-write
The SNMP contact security name.
                                   tlPASnmpContactPrivPassword 1.3.6.1.4.1.850.90.1.1.2.2.1.8 displaystring read-write
The SNMP contact priv password to use for sending V3 traps.
                                   tlPASnmpContactAuthPassword 1.3.6.1.4.1.850.90.1.1.2.2.1.9 displaystring read-write
The SNMP contact auth password to use for sending V3 traps.
         tlUPS 1.3.6.1.4.1.850.100
                 tlUpsObjects 1.3.6.1.4.1.850.100.1
                     tlUpsIdent 1.3.6.1.4.1.850.100.1.1
                         tlUpsIdentUpsSoftwareChecksum 1.3.6.1.4.1.850.100.1.1.1 integer32 read-only
A checksum for the UPS software.
                         tlUpsIdentSerialNum 1.3.6.1.4.1.850.100.1.1.2 displaystring read-only
Serial number for the UPS.
                         tlUpsIdentID 1.3.6.1.4.1.850.100.1.1.3 integer32 read-write
A user-supplied ID for the UPS.
                         tlUpsSnmpCardSerialNum 1.3.6.1.4.1.850.100.1.1.4 displaystring read-only
Serial number for the UPS.
                         tlUpsSelectedDeviceID 1.3.6.1.4.1.850.100.1.1.5 integer32 read-write
The device ID selected to be used for retrieving data for this mib. As the snmp web card has only one device, this is read only for it
                         tlUpsLocation 1.3.6.1.4.1.850.100.1.1.6 displaystring read-write
The device location string.
                     tlUpsBattery 1.3.6.1.4.1.850.100.1.2
                         tlUpsBatteryAge 1.3.6.1.4.1.850.100.1.2.1 displaystring read-only
The age of the battery in years. This is equal to the current date minus tlConfigBattReplDate.
                         tlUpsTemperatureF 1.3.6.1.4.1.850.100.1.2.2 integer32 read-only
The temperature of the battery, in Farenheight degrees. This is calculated from upsBatteryTemperature, which is in Celsius degrees.
                     tlUpsInput 1.3.6.1.4.1.850.100.1.3
                         tlUpsInputNumVoltages 1.3.6.1.4.1.850.100.1.3.1 nonnegativeinteger read-only
The number of input voltages. Phase to phase or phase to neutral. This variable indicates the number of rows in the input table.
                         tlUpsInputVoltageTable 1.3.6.1.4.1.850.100.1.3.2 no-access
A list of voltage input table entries. The number of entries is given by the value of tlUpsInputNumVoltages.
                             tlUpsInputVoltageEntry 1.3.6.1.4.1.850.100.1.3.2.1 no-access
An entry containing information applicable to a particular input voltage.
                                 tlUpsInputVoltageIndex 1.3.6.1.4.1.850.100.1.3.2.1.1 positiveinteger no-access
The input voltage identifier.
                                 tlUpsInputVoltageType 1.3.6.1.4.1.850.100.1.3.2.1.2 integer read-only
Whether voltage measured is phase to phase or phase to neutral. Enumeration: 'phaseToNeutral': 0, 'phaseToPhase': 1.
                                 tlUpsInputVoltage 1.3.6.1.4.1.850.100.1.3.2.1.3 nonnegativeinteger read-only
The magnitude of the present input voltage. A value of 6553 indicates Unknown.
                     tlUpsOutput 1.3.6.1.4.1.850.100.1.4
                         tlUpsOutputPowerTotal 1.3.6.1.4.1.850.100.1.4.5 positiveinteger read-only
The power capacity of the device.
                         tlUpsOutputCircuits 1.3.6.1.4.1.850.100.1.4.6 nonnegativeinteger read-only
The number of output circuits. This variable indicates the number of rows in the output circuit table.
                         tlUpsOutputCircuitTable 1.3.6.1.4.1.850.100.1.4.7 no-access
A list of output currents table entries. The number of entries is given by the value of tlUpsOutputNumCircuits.
                             tlUpsOutputCircuitEntry 1.3.6.1.4.1.850.100.1.4.7.1 no-access
An entry containing information applicable to a particular output circuit.
                                 tlUpsOutputCircuitIndex 1.3.6.1.4.1.850.100.1.4.7.1.1 positiveinteger no-access
The output circuit identifier.
                                 tlUpsOutputCircuitStatus 1.3.6.1.4.1.850.100.1.4.7.1.2 integer read-only
Whether the breaker is open or closed. Enumeration: 'open': 0, 'closed': 1.
                                 tlUpsOutputCircuitLoadCurrent 1.3.6.1.4.1.850.100.1.4.7.1.3 nonnegativeinteger read-only
The magnitude of the present output current in tenths of an amp. A value of 65534 indicates Unknown.
                     tlUpsAlarm 1.3.6.1.4.1.850.100.1.6
                         tlUpsAlarmsPresent 1.3.6.1.4.1.850.100.1.6.1 gauge32 read-only
The present number of active alarm conditions.
                         tlUpsAlarmTable 1.3.6.1.4.1.850.100.1.6.2 no-access
A list of alarm table entries.
                             tlUpsAlarmEntry 1.3.6.1.4.1.850.100.1.6.2.1 no-access
An entry containing information applicable to a particular alarm.
                                 tlUpsAlarmId 1.3.6.1.4.1.850.100.1.6.2.1.1 positiveinteger read-only
A unique identifier for an alarm condition.
                                 tlUpsAlarmDescr 1.3.6.1.4.1.850.100.1.6.2.1.2 autonomoustype read-only
A description of the alarm condition.
                                 tlUpsAlarmTime 1.3.6.1.4.1.850.100.1.6.2.1.3 timestamp read-only
The value of sysUpTime when the alarm condition was detected.
                                 tlUpsAlarmDetail 1.3.6.1.4.1.850.100.1.6.2.1.4 displaystring read-only
A textual description of the alarm condition.
                                 tlUpsAlarmDeviceId 1.3.6.1.4.1.850.100.1.6.2.1.5 positiveinteger read-only
A numeric identifier for the device on which the alarm is active.
                                 tlUpsAlarmDeviceName 1.3.6.1.4.1.850.100.1.6.2.1.6 displaystring read-only
A string identifier for the device on which the alarm is active.
                                 tlUpsAlarmLocation 1.3.6.1.4.1.850.100.1.6.2.1.7 displaystring read-only
The location of the device on which the alarm is active.
                                 tlUpsAlarmGroup 1.3.6.1.4.1.850.100.1.6.2.1.8 integer read-only
The category/group of this alarm. Enumeration: 'info': 3, 'status': 4, 'custom': 6, 'critical': 1, 'offline': 5, 'warning': 2.
                                 tlUpsAlarmIp 1.3.6.1.4.1.850.100.1.6.2.1.9 ipaddress read-only
The originating IP address associated with this alarm.
                                 tlUpsAlarmMac 1.3.6.1.4.1.850.100.1.6.2.1.10 displaystring read-only
The originating mac address associated with this alarm.
                         tlUpsWellKnownAlarms 1.3.6.1.4.1.850.100.1.6.3
                             tlUpsAlarmPrimaryPowerOutage 1.3.6.1.4.1.850.100.1.6.3.1
The primary power source is not present.
                             tlUpsAlarmSecondaryPowerOutage 1.3.6.1.4.1.850.100.1.6.3.2
The secondary power source is not present.
                             tlUpsAlarmLoadLevelAboveThreshold 1.3.6.1.4.1.850.100.1.6.3.3
The load level is above the designated threshold.
                             tlUpsAlarmOutputCurrentChanged 1.3.6.1.4.1.850.100.1.6.3.4
The output current changed from its last known value.
                             tlUpsAlarmBatteryAgeAboveThreshold 1.3.6.1.4.1.850.100.1.6.3.5
One or more batteries have been determined to require replacement.
                             tlUpsAlarmLoadOff 1.3.6.1.4.1.850.100.1.6.3.6
The load is off.
                             tlUpsAlarmUserDefined 1.3.6.1.4.1.850.100.1.6.3.7
A user-defined event is in alarm.
                             tlUpsAlarmBatteryBad 1.3.6.1.4.1.850.100.1.6.3.8
One or more batteries have been determined to require replacement.
                             tlUpsAlarmOnBattery 1.3.6.1.4.1.850.100.1.6.3.9
The UPS is drawing power from the batteries.
                             tlUpsAlarmLowBattery 1.3.6.1.4.1.850.100.1.6.3.10
The remaining battery run-time is less than or equal to upsConfigLowBattTime.
                             tlUpsAlarmDepletedBattery 1.3.6.1.4.1.850.100.1.6.3.11
The UPS will be unable to sustain the present load when and if the utility power is lost.
                             tlUpsAlarmTempBad 1.3.6.1.4.1.850.100.1.6.3.12
A temperature is out of tolerance.
                             tlUpsAlarmInputBad 1.3.6.1.4.1.850.100.1.6.3.13
An input condition is out of tolerance.
                             tlUpsAlarmOutputBad 1.3.6.1.4.1.850.100.1.6.3.14
An output condition (other than OutputOverload) is out of tolerance.
                             tlUpsAlarmOutputOverload 1.3.6.1.4.1.850.100.1.6.3.15
The output load exceeds the UPS output capacity.
                             tlUpsAlarmOnBypass 1.3.6.1.4.1.850.100.1.6.3.16
The Bypass is presently engaged on the UPS.
                             tlUpsAlarmBypassBad 1.3.6.1.4.1.850.100.1.6.3.17
The Bypass is out of tolerance.
                             tlUpsAlarmOutputOffAsRequested 1.3.6.1.4.1.850.100.1.6.3.18
The UPS has shutdown as requested, i.e., the output is off.
                             tlUpsAlarmUpsOffAsRequested 1.3.6.1.4.1.850.100.1.6.3.19
The entire UPS has shutdown as commanded.
                             tlUpsAlarmChargerFailed 1.3.6.1.4.1.850.100.1.6.3.20
An uncorrected problem has been detected within the UPS charger subsystem.
                             tlUpsAlarmUpsOutputOff 1.3.6.1.4.1.850.100.1.6.3.21
The output of the UPS is in the off state.
                             tlUpsAlarmUpsSystemOff 1.3.6.1.4.1.850.100.1.6.3.22
The UPS system is in the off state.
                             tlUpsAlarmFanFailure 1.3.6.1.4.1.850.100.1.6.3.23
The failure of one or more fans in the UPS has been detected.
                             tlUpsAlarmFuseFailure 1.3.6.1.4.1.850.100.1.6.3.24
The failure of one or more fuses has been detected.
                             tlUpsAlarmGeneralFault 1.3.6.1.4.1.850.100.1.6.3.25
A general fault in the UPS has been detected.
                             tlUpsAlarmDiagnosticTestFailed 1.3.6.1.4.1.850.100.1.6.3.26
The result of the last diagnostic test indicates a failure.
                             tlUpsAlarmCommunicationsLost 1.3.6.1.4.1.850.100.1.6.3.27
A problem has been encountered in the communications between the agent and the UPS.
                             tlUpsAlarmAwaitingPower 1.3.6.1.4.1.850.100.1.6.3.28
The UPS output is off and the UPS is awaiting the return of input power.
                             tlUpsAlarmShutdownPending 1.3.6.1.4.1.850.100.1.6.3.29
A upsShutdownAfterDelay countdown is underway.
                             tlUpsAlarmShutdownImminent 1.3.6.1.4.1.850.100.1.6.3.30
The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.
                             tlUpsAlarmTestInProgress 1.3.6.1.4.1.850.100.1.6.3.31
A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.
                             tlUpsAlarmCircuitBreaker1Open 1.3.6.1.4.1.850.100.1.6.3.32
Circuit breakers #1 is open.
                             tlUpsAlarmCircuitBreaker2Open 1.3.6.1.4.1.850.100.1.6.3.33
Circuit breakers #2 is open.
                             tlUpsAlarmCircuitBreaker3Open 1.3.6.1.4.1.850.100.1.6.3.34
Circuit breakers #3 is open.
                             tlUpsAlarmCircuitBreaker4Open 1.3.6.1.4.1.850.100.1.6.3.35
Circuit breakers #4 is open.
                             tlUpsAlarmCircuitBreaker5Open 1.3.6.1.4.1.850.100.1.6.3.36
Circuit breakers #5 is open.
                             tlUpsAlarmCircuitBreaker6Open 1.3.6.1.4.1.850.100.1.6.3.37
Circuit breakers #6 is open.
                             tlUpsAlarmCircuitBreaker7Open 1.3.6.1.4.1.850.100.1.6.3.38
Circuit breakers #7 is open.
                             tlUpsAlarmCircuitBreaker8Open 1.3.6.1.4.1.850.100.1.6.3.39
Circuit breakers #8 is open.
                             tlUpsAlarmCurrent1AboveThreshold 1.3.6.1.4.1.850.100.1.6.3.40
The output current on line 1 exceeds load limits.
                             tlUpsAlarmCurrent2AboveThreshold 1.3.6.1.4.1.850.100.1.6.3.41
The output current on line 2 exceeds load limits.
                             tlUpsAlarmCurrent3AboveThreshold 1.3.6.1.4.1.850.100.1.6.3.42
The output current on line 3 exceeds load limits.
                         tlUpsAlarmDevName 1.3.6.1.4.1.850.100.1.6.7 displaystring read-only
The name of the device, tlDevName, corresponding to the device that is associated with this alarm.
                         tlUpsAlarmDevLocation 1.3.6.1.4.1.850.100.1.6.8 displaystring read-only
The location of the device, tlDevLocation, corresponding to the device that is associated with this alarm.
                         tlUpsAlarmCategory 1.3.6.1.4.1.850.100.1.6.9 integer32 read-only
The category, tlDevEvtCategory, of this alarm.
                     tlUpsTest 1.3.6.1.4.1.850.100.1.7
                         tlUpsTestDate 1.3.6.1.4.1.850.100.1.7.1 displaystring read-only
The date of the last self-test run on the ups, in the format YYYYMMDD.
                         tlUpsTestResultsDetail 1.3.6.1.4.1.850.100.1.7.2 displaystring read-only
Result of the last self-test run on the ups.
                     tlUpsControl 1.3.6.1.4.1.850.100.1.8
                         tlUpsWatchdogSupported 1.3.6.1.4.1.850.100.1.8.1 truthvalue read-only
Indicates whether or not this UPS supports a watchdog reboot.
                         tlUpsWatchdogSecsBeforeReboot 1.3.6.1.4.1.850.100.1.8.2 nonnegativeinteger read-write
The maximum number of seconds that can expire between polls that the engine makes to the UPS for data. If this time runs out, then the UPS will cycle its outputs. Set this to zero to turns disable this feature.
                         tlUpsWellKnownControls 1.3.6.1.4.1.850.100.1.8.3
                             tlUpsControlSelfTest 1.3.6.1.4.1.850.100.1.8.3.1 truthvalue read-write
Set to TRUE to initiate Self Test
                             tlUpsControlRamp 1.3.6.1.4.1.850.100.1.8.3.2 truthvalue read-write
Set to TRUE to initiate Ramp
                             tlUpsControlShed 1.3.6.1.4.1.850.100.1.8.3.3 truthvalue read-write
Set to TRUE to initiate Shed
                             tlUpsControlUpsOn 1.3.6.1.4.1.850.100.1.8.3.4 truthvalue read-write
Set to TRUE to turn UPS on
                             tlUpsControlUpsOff 1.3.6.1.4.1.850.100.1.8.3.5 truthvalue read-write
Set to TRUE to turn UPS off
                     tlUpsConfig 1.3.6.1.4.1.850.100.1.9
                         tlUpsConfigBattReplDate 1.3.6.1.4.1.850.100.1.9.1 displaystring read-write
The date on which the battery was last replaced, in the format YYYYMMDD.
                     tlUpsOutlet 1.3.6.1.4.1.850.100.1.10
                           tlUpsOutletNumOutlets 1.3.6.1.4.1.850.100.1.10.1 nonnegativeinteger read-only
The number of available Outlets in this device.
                           tlUpsOutletTable 1.3.6.1.4.1.850.100.1.10.2 no-access
A list of all device Outlets for all devices.
                               tlUpsOutletEntry 1.3.6.1.4.1.850.100.1.10.2.1 no-access
An entry containing Outlet information applicable to a particular device managed by this agent.
                                   tlUpsOutletIndex 1.3.6.1.4.1.850.100.1.10.2.1.1 positiveinteger read-only
This is the index number of this Outlet for the device indicated by tlDeviceIndex.
                                   tlUpsOutletState 1.3.6.1.4.1.850.100.1.10.2.1.2 integer read-only
The current state of the Outlet. Enumeration: 'unknown': 0, 'off': 1, 'on': 2.
                                   tlUpsOutletType 1.3.6.1.4.1.850.100.1.10.2.1.3 integer32 read-only
This is a bit field that indicates the type of this Outlet. When 0, the outlet is not controllable and has none of the other features indicated in the bit map. When non-zero, the features present for this outlet can be interpreted with the definition. Bit Display 0 Reserved, may be 1 or 0 1 Controllable 2 3 4 5 6 7 8 9 10 11 12 13 14 15
                                   tlUpsOutletControl 1.3.6.1.4.1.850.100.1.10.2.1.4 integer read-write
Controls the state of the Outlet. Enumeration: 'turnOn': 2, 'turnOff': 1, 'cycle': 3.
                                   tlUpsOutletName 1.3.6.1.4.1.850.100.1.10.2.1.5 displaystring read-write
A string identifying the devices attached to the output(s) of the device.
                                   tlUpsOutletRampAction 1.3.6.1.4.1.850.100.1.10.2.1.6 integer read-write
The ramp action to take on the Outlet. Enumeration: 'remainOff': 0, 'turnOnAfterDelay': 1.
                                   tlUpsOutletRampDataType 1.3.6.1.4.1.850.100.1.10.2.1.7 integer read-write
The type of data associated with ramp action. Enumeration: 'delayInSeconds': 0.
                                   tlUpsOutletRampData 1.3.6.1.4.1.850.100.1.10.2.1.8 integer32 read-write
The data value associated with type of ramp data.
                                   tlUpsOutletShedAction 1.3.6.1.4.1.850.100.1.10.2.1.9 integer read-write
The shed action to take on the Outlet. Enumeration: 'turnOffAfterDelay': 1, 'remainOn': 0.
                                   tlUpsOutletShedDataType 1.3.6.1.4.1.850.100.1.10.2.1.10 integer read-write
The type of data associated with shed action. Enumeration: 'delayInSeconds': 0.
                                   tlUpsOutletShedData 1.3.6.1.4.1.850.100.1.10.2.1.11 integer32 read-write
The data value associated with type of shed data.
                                   tlUpsOutletGroupNdx 1.3.6.1.4.1.850.100.1.10.2.1.12 integer32 read-write
tlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped.
                                   tlUpsOutletCurrent 1.3.6.1.4.1.850.100.1.10.2.1.13 positiveinteger read-only
The value of this outlet's current, represented as 0.1A.
                                   tlUpsOutletPower 1.3.6.1.4.1.850.100.1.10.2.1.14 positiveinteger read-only
The value of this outlet's power in watts.
                     tlUpsOutletGroup 1.3.6.1.4.1.850.100.1.11
                           tlUpsOutletNumOutletGroups 1.3.6.1.4.1.850.100.1.11.1 nonnegativeinteger read-only
The number of available Outlet Groups in this device.
                           tlUpsOutletGroupTable 1.3.6.1.4.1.850.100.1.11.2 no-access
A list of device outlet group entries. The number of entries is given by the value of tlUpsOutletNumOutletGroups.
                               tlUpsOutletGroupEntry 1.3.6.1.4.1.850.100.1.11.2.1 no-access
An entry containing outlet group information applicable to a particular device managed by this agent
                                   tlUpsOutletGroupIndex 1.3.6.1.4.1.850.100.1.11.2.1.1 positiveinteger read-only
This is the index number of this load group for the device.
                                   tlUpsOutletGroupRowStatus 1.3.6.1.4.1.850.100.1.11.2.1.2 rowstatus read-write
Row status for the tlUpsOutletGroupTable
                                   tlUpsOutletGroupName 1.3.6.1.4.1.850.100.1.11.2.1.3 displaystring read-write
The name of this outlet group.
                                   tlUpsOutletGroupDesc 1.3.6.1.4.1.850.100.1.11.2.1.4 displaystring read-write
A description for this outlet group.
                                   tlUpsOutletGroupState 1.3.6.1.4.1.850.100.1.11.2.1.5 integer read-only
The current state of the outlet group. Enumeration: 'mixed': 3, 'unknown': 0, 'off': 1, 'on': 2.
                                   tlUpsOutletGroupControl 1.3.6.1.4.1.850.100.1.11.2.1.6 integer read-write
Controls the state of every outlet associated with the group. Enumeration: 'turnOn': 2, 'turnOff': 1, 'cycle': 3.
                     tlUpsMainOutlet 1.3.6.1.4.1.850.100.1.12
                           tlUpsMainOutletState 1.3.6.1.4.1.850.100.1.12.1 integer read-only
The current state of the main output of the device. Enumeration: 'mixed': 3, 'unknown': 0, 'off': 1, 'on': 2.
                           tlUpsMainOutletControllable 1.3.6.1.4.1.850.100.1.12.2 truthvalue read-only
Indicates if this device has controllable outlets
                           tlUpsMainOutletControl 1.3.6.1.4.1.850.100.1.12.3 integer read-write
Controls the state of the main outlet of the device. Enumeration: 'turnOn': 2, 'idle': 0, 'turnOff': 1, 'cycle': 3.
                 tlUpsTraps 1.3.6.1.4.1.850.100.2
                     tlUpsTrapAlarmEntryAdded 1.3.6.1.4.1.850.100.2.3
This trap is sent each time an alarm is inserted into to the alarm table.
                     tlUpsTrapAlarmEntryRemoved 1.3.6.1.4.1.850.100.2.4
This trap is sent each time an alarm is removed from the alarm table.
                     tlUpsTrapSystemStartup 1.3.6.1.4.1.850.100.2.5
Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format)
                     tlUpsTrapSystemShutdown 1.3.6.1.4.1.850.100.2.6
Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format)
                       tlUpsTrapAlarmEntryAddedV1 1.3.6.1.4.1.850.100.20.3
This trap is sent each time an alarm is inserted into to the alarm table.
                       tlUpsTrapAlarmEntryRemovedV1 1.3.6.1.4.1.850.100.20.4
This trap is sent each time an alarm is removed from the alarm table.
         tlEnviroSense 1.3.6.1.4.1.850.101
                 tlEnvEnvironment 1.3.6.1.4.1.850.101.1
                     tlEnvTemperatureData 1.3.6.1.4.1.850.101.1.1
                         tlEnvTemperatureC 1.3.6.1.4.1.850.101.1.1.1 integer32 read-only
The ambient temperature (C).
                         tlEnvTemperatureF 1.3.6.1.4.1.850.101.1.1.2 integer32 read-only
The ambient temperature (F).
                         tlEnvTemperatureLowLimit 1.3.6.1.4.1.850.101.1.1.3 integer32 read-write
The lower alarm limit for ambient temperature (F).
                         tlEnvTemperatureHighLimit 1.3.6.1.4.1.850.101.1.1.4 integer32 read-write
The upper alarm limit for ambient temperature (F).
                         tlEnvTemperatureInAlarm 1.3.6.1.4.1.850.101.1.1.5 truthvalue read-only
Indicates whether or not temperature is in alarm.
                     tlEnvHumidityData 1.3.6.1.4.1.850.101.1.2
                         tlEnvHumidity 1.3.6.1.4.1.850.101.1.2.1 integer32 read-only
The ambient humidity (%).
                         tlEnvHumidityLowLimit 1.3.6.1.4.1.850.101.1.2.2 integer32 read-write
The lower alarm limit for ambient humidity (%).
                         tlEnvHumidityHighLimit 1.3.6.1.4.1.850.101.1.2.3 integer32 read-write
The upper alarm limit for ambient humidity (%).
                         tlEnvHumidityInAlarm 1.3.6.1.4.1.850.101.1.2.4 truthvalue read-only
Indicates whether or not humidity is in alarm.
                 tlEnvContacts 1.3.6.1.4.1.850.101.2
                     tlEnvContactTable 1.3.6.1.4.1.850.101.2.1 no-access
A table of contacts.
                         tlEnvContactEntry 1.3.6.1.4.1.850.101.2.1.1 no-access
An entry containing information applicable to a particular contact.
                             tlEnvContactIndex 1.3.6.1.4.1.850.101.2.1.1.1 positiveinteger read-only
The table row index for the contact.
                             tlEnvContactName 1.3.6.1.4.1.850.101.2.1.1.2 displaystring read-write
The name or description of the contact.
                             tlEnvContactStatus 1.3.6.1.4.1.850.101.2.1.1.3 integer read-only
The current status of the contact. Enumeration: 'alarm': 1, 'normal': 0.
                             tlEnvContactConfig 1.3.6.1.4.1.850.101.2.1.1.4 integer read-write
The configuration of the contact. Enumeration: 'normallyOpen': 0, 'normallyClosed': 1.
         tlCooling 1.3.6.1.4.1.850.103
                 tlCoolingEnvironment 1.3.6.1.4.1.850.103.1
                     tlCoolingIdent 1.3.6.1.4.1.850.103.1.1
                         tlCoolingModel 1.3.6.1.4.1.850.103.1.1.1 displaystring read-only
The model name for the AC Unit.
                         tlCoolingManufacturer 1.3.6.1.4.1.850.103.1.1.2 displaystring read-only
The manufacturer of the AC Unit.
                         tlCoolingSerialNumber 1.3.6.1.4.1.850.103.1.1.3 displaystring read-only
The serial number of the AC unit.
                         tlCoolingFirmwareVersion 1.3.6.1.4.1.850.103.1.1.4 displaystring read-only
The firmware version of the AC Unit.
                         tlCoolingHostSoftwareVersion 1.3.6.1.4.1.850.103.1.1.5 displaystring read-only
The hardware version of the AC unit.
                         tlCoolingName 1.3.6.1.4.1.850.103.1.1.6 displaystring read-write
The user defined name for the AC Unit.
                         tlCoolingLocation 1.3.6.1.4.1.850.103.1.1.7 displaystring read-write
The user defined location of the AC Unit.
                     tlCoolingStatus 1.3.6.1.4.1.850.103.1.2
                         tlCoolingCondOutletTemp 1.3.6.1.4.1.850.103.1.2.1 integer read-only
The condenser outlet air stream temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.
                         tlCoolingCondInletTemp 1.3.6.1.4.1.850.103.1.2.2 integer read-only
The condenser inlet air stream temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.
                         tlCoolingRefrigerantTemp 1.3.6.1.4.1.850.103.1.2.3 integer read-only
The temperature of the refrigerant in the suction line. This is displayed in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.
                         tlCoolingEvapSurfaceTemp 1.3.6.1.4.1.850.103.1.2.4 integer read-only
The surface temperature of the evaporator in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.
                         tlCoolingSuctionPressure 1.3.6.1.4.1.850.103.1.2.5 integer read-only
The pressure of the compressor suction line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits.
                         tlCoolingDischargePressure 1.3.6.1.4.1.850.103.1.2.6 integer read-only
The pressure of the compressor discharge line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits.
                         tlCoolingEvapFanSpeed 1.3.6.1.4.1.850.103.1.2.7 integer read-only
The current speed of the evaporator fan. Enumeration: 'med': 3, 'medLow': 2, 'off': 0, 'medHi': 4, 'hi': 5, 'low': 1.
                         tlCoolingCondFanSpeed 1.3.6.1.4.1.850.103.1.2.8 integer read-only
The current speed of the condenser fan. Enumeration: 'hi': 2, 'off': 0, 'low': 1.
                         tlCoolingCompFrequency 1.3.6.1.4.1.850.103.1.2.9 integer read-only
The operating frequency of the compressor in tenths of Arms.
                         tlCoolingEEVPercentage 1.3.6.1.4.1.850.103.1.2.10 integer read-only
The opening percentage of the EEV.
                         tlCoolingUnitCurrent 1.3.6.1.4.1.850.103.1.2.11 integer read-only
The the total current draw of the unit in tenths of Arms.
                         tlCoolingFanCurrent 1.3.6.1.4.1.850.103.1.2.12 integer read-only
Thethe current draw of the Evaporator and Condenser fans in tents of Arms.
                         tlCoolingCompCurrent 1.3.6.1.4.1.850.103.1.2.13 integer read-only
The operating current of the compressor in Arms.
                         tlCoolingReturnAirTemp 1.3.6.1.4.1.850.103.1.2.14 integer read-only
The return air temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.
                         tlCoolingSuctionTemp 1.3.6.1.4.1.850.103.1.2.15 integer read-only
The temperature of the compressor suction line in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.
                         tlCoolingSupplyAirTemp 1.3.6.1.4.1.850.103.1.2.16 integer read-only
The supply air temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.
                     tlCoolingRunTimes 1.3.6.1.4.1.850.103.1.3
                         tlCoolingAirFilterRunHours 1.3.6.1.4.1.850.103.1.3.1 integer32 read-only
Total hours the air filter has been under operation.
                         tlCoolingEvapFanRunDays 1.3.6.1.4.1.850.103.1.3.2 integer32 read-only
Total days the evaporator fan has been under operation.
                         tlCoolingCondFanRunDays 1.3.6.1.4.1.850.103.1.3.3 integer32 read-only
Total days the condenser fan has been under operation.
                         tlCoolingCompressorRunDays 1.3.6.1.4.1.850.103.1.3.4 integer32 read-only
Total days the compressor has been under operation.
                         tlCoolingCondPumpRunDays 1.3.6.1.4.1.850.103.1.3.5 integer32 read-only
Total days the condensate pump has been under operation.
                         tlCoolingAtomizerRunDays 1.3.6.1.4.1.850.103.1.3.6 integer32 read-only
Total days the atomizer has been under operation.
                     tlCoolingConfig 1.3.6.1.4.1.850.103.1.4
                         tlCoolingOnOff 1.3.6.1.4.1.850.103.1.4.1 integer read-write
Turn the unit off or on. Enumeration: 'turnOffUnit': 0, 'turnOnUnit': 1.
                         tlCoolingSetPointTemp 1.3.6.1.4.1.850.103.1.4.2 integer read-write
The set point temperature the unit will control the temperature to in tenths of degrees in Celcius or Fahrenheit based upon tleCoolDisplayUnits.
                         tlCoolingAutoStart 1.3.6.1.4.1.850.103.1.4.3 integer read-write
Specified if the unit should start automatically on power up. Enumeration: 'disabled': 0, 'enabled': 1.
                         tlCoolingFanSpeedOverride 1.3.6.1.4.1.850.103.1.4.4 integer read-write
Speed of evaporator fan set by the user. Enumeration: 'med': 3, 'medLow': 2, 'medHi': 4, 'hi': 5, 'low': 1, 'autoFanSpeed': 0.
                         tlCoolingControlType 1.3.6.1.4.1.850.103.1.4.5 integer read-write
Which temperature to be used as a control point. Enumeration: 'returnAirTemp': 0, 'remoteTemperature': 1.
                         tlCoolingCurrentRemoteTemp 1.3.6.1.4.1.850.103.1.4.6 integer read-write
The external remote temperature in tenths of degrees in Celcius or Fahrenheit depending upon value of tlCoolingDisplayUnits
                         tlCoolingDisplayUnits 1.3.6.1.4.1.850.103.1.4.7 integer read-write
Selects English or Metric display for all readings. Enumeration: 'metric': 0, 'english': 1.
                         tlCoolingBeepOnKey 1.3.6.1.4.1.850.103.1.4.8 integer read-write
Indicates if the display sounds a beep when a key is pressed. Enumeration: 'beepOn': 1, 'noBeep': 0.
                         tlCoolingOutputRelaySource 1.3.6.1.4.1.850.103.1.4.9 integer read-write
The alarm level that causes the ouput relay to activate. Enumeration: 'disabled': 0, 'allAlarmsAndWarnings': 1, 'criticalAlarmsOnly': 2.
                         tlCoolingOffOnLeak 1.3.6.1.4.1.850.103.1.4.10 integer read-write
Indicates if the unit should stop cooling when leak input is activated. Enumeration: 'turnOff': 0, 'alarmOnly': 1.
                         tlCoolingOffOnInputContact 1.3.6.1.4.1.850.103.1.4.11 integer read-write
Indicates if the unit should stop cooling when input contact is activated. Enumeration: 'turnOff': 0, 'alarmOnly': 1.
                         tlCoolingInputContactType 1.3.6.1.4.1.850.103.1.4.12 integer read-write
The input contact type. Enumeration: 'noRelay': 1, 'ncRelay': 0.
                         tlCoolingOutputRelayDefault 1.3.6.1.4.1.850.103.1.4.13 integer read-write
Type of contact to make when output relay is activated. Enumeration: 'nc': 0, 'no': 1.
                         tlCoolingAirFilterInterval 1.3.6.1.4.1.850.103.1.4.14 integer32 read-write
The number of weeks before the air filter needs to be changed.
                         tlCoolingWaterLeakContactType 1.3.6.1.4.1.850.103.1.4.15 integer read-write
The input contact type. Enumeration: 'noRelay': 0, 'ncRelay': 1.
                     tlCoolingThresholds 1.3.6.1.4.1.850.103.1.5
                         tlCoolingMaxAirFilterRunHours 1.3.6.1.4.1.850.103.1.5.1 integer32 read-write
The maximum interval for air filter run hours before warning is annunciated.
                         tlCoolingEnableAirFilterAlarm 1.3.6.1.4.1.850.103.1.5.2 integer read-write
When enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded. Enumeration: 'disabled': 0, 'enabled': 1.
                         tlCoolingMaxSupplyTemp 1.3.6.1.4.1.850.103.1.5.3 integer read-write
Maximum allowed supply air temperature before firing an alarm.
                         tlCoolingMinSupplyTemp 1.3.6.1.4.1.850.103.1.5.4 integer read-write
Minimum allowed supply air temperature allowed before firing an alarm.
                         tlCoolingTempDiffAlarm 1.3.6.1.4.1.850.103.1.5.5 integer read-write
Maximum allowed air temperature deviation from set allowed before firing an alarm.
                         tlCoolingMaxReturnAirTemp 1.3.6.1.4.1.850.103.1.5.6 integer read-write
When enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded.
                 tlCoolingAlarm 1.3.6.1.4.1.850.103.6
                     tlCoolingWellKnownAlarms 1.3.6.1.4.1.850.103.6.3
                         tlCoolingSupplyAirSensorFault 1.3.6.1.4.1.850.103.6.3.1
The supply air sensor is in fault.
                         tlCoolingReturnAirSensorFault 1.3.6.1.4.1.850.103.6.3.2
The return air sensor is in fault.
                         tlCoolingCondenserInletAirSensorFault 1.3.6.1.4.1.850.103.6.3.3
The condenser inlet air sensor is in fault.
                         tlCoolingCondenserOutletAirSensorFault 1.3.6.1.4.1.850.103.6.3.4
The condenser outlet air sensor is in fault.
                         tlCoolingSuctionTemperatureSensorFault 1.3.6.1.4.1.850.103.6.3.5
The suction temperature sensor is in fault.
                         tlCoolingEvaporatorTemperatureSensorFault 1.3.6.1.4.1.850.103.6.3.6
The evaporator temperature sensor is in fault.
                         tlCoolingAirFilterClogged 1.3.6.1.4.1.850.103.6.3.7
The air filter is clogged.
                         tlCoolingAirFilterRunHoursViolation 1.3.6.1.4.1.850.103.6.3.8
The air filter run hours was violated.
                         tlCoolingSuctionPressureSensorFault 1.3.6.1.4.1.850.103.6.3.9
The suction pressure sensor is in fault.
                         tlCoolingInverterCommunicationsFault 1.3.6.1.4.1.850.103.6.3.10
The inverter communications is in fault.
                         tlCoolingRemoteShutdownViaInputContact 1.3.6.1.4.1.850.103.6.3.11
A remote shutdown was triggerd by an input contact.
                         tlCoolingCondensatePumpFault 1.3.6.1.4.1.850.103.6.3.12
The condensate pump is in fault.
                         tlCoolingLowRefrigerantStartupFault 1.3.6.1.4.1.850.103.6.3.13
The low refrigerant startup is in fault.
                         tlCoolingCondenserFanFault 1.3.6.1.4.1.850.103.6.3.14
The condenser fan is in fault.
                         tlCoolingCondenserFailure 1.3.6.1.4.1.850.103.6.3.15
The condenser has failed.
                         tlCoolingEvaporatorCoolingFailure 1.3.6.1.4.1.850.103.6.3.16
The evaporator cooling is in fault.
                         tlCoolingReturnAirTempHigh 1.3.6.1.4.1.850.103.6.3.17
The return air temperature is high.
                         tlCoolingSupplyAirTempHigh 1.3.6.1.4.1.850.103.6.3.18
The supply air temperature is high.
                         tlCoolingEvaporatorFailure 1.3.6.1.4.1.850.103.6.3.19
The evaporator has failed.
                         tlCoolingEvaporatorFreezeUp 1.3.6.1.4.1.850.103.6.3.20
The evaporator is frozen.
                         tlCoolingDischargePressureHigh 1.3.6.1.4.1.850.103.6.3.21
The discharge pressure is high.
                         tlCoolingPressureGaugeFailure 1.3.6.1.4.1.850.103.6.3.22
The pressure gauge has failed.
                         tlCoolingDischargePressurePersistentHigh 1.3.6.1.4.1.850.103.6.3.23
The discharge pressure is persistently high.
                         tlCoolingSuctionPressureLowStartFailure 1.3.6.1.4.1.850.103.6.3.24
Cannot start due to low suction pressure.
                         tlCoolingSuctionPressureLow 1.3.6.1.4.1.850.103.6.3.25
The suction pressure is low.
                         tlCoolingSuctionPressurePersistentLow 1.3.6.1.4.1.850.103.6.3.26
The suction pressure is persistently low.
                         tlCoolingStartupLinePressureImbalance 1.3.6.1.4.1.850.103.6.3.27
The startup line pressure is in imbalance.
                         tlCoolingCompressorFailure 1.3.6.1.4.1.850.103.6.3.28
The compressor has failed.
                         tlCoolingCurrentLimit 1.3.6.1.4.1.850.103.6.3.29
The current is out of range.
                         tlCoolingWaterLeak 1.3.6.1.4.1.850.103.6.3.30
Water is leaking.
                         tlCoolingFanUnderCurrent 1.3.6.1.4.1.850.103.6.3.31
The fan is under current.
                         tlCoolingFanOverCurrent 1.3.6.1.4.1.850.103.6.3.32
The fan is over current.
                         tlCoolingDischargePressureSensorFault 1.3.6.1.4.1.850.103.6.3.33
The discharge pressure sensor is in fault.
                         tlCoolingWaterFull 1.3.6.1.4.1.850.103.6.3.34
Water is Full.