Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 ethernetOamLinkMonCfgTable 1.3.6.1.4.1.11863.6.60.1.2.1 no-access
A table that contains link monitoring configuration of each port. Through link monitoring, you can detect and find faults in various environments at the data link layer. Link monitoring uses event notification PDUs. When a link event occurs, the local link notifies the OAM entity of the event.
     ethernetOamLinkMonCfgEntry 1.3.6.1.4.1.11863.6.60.1.2.1.1 no-access
An entry that contains the link monitoring configuration of each port.
         ethernetOamLinkMonCfgPort 1.3.6.1.4.1.11863.6.60.1.2.1.1.1 displaystring read-only
Displays the port number.
         ethernetOamLinkMonCfgEvent 1.3.6.1.4.1.11863.6.60.1.2.1.1.2 integer read-only
Select various types of link monitoring. Enumeration: 'frame': 2, 'symbol-period': 1, 'frame-seconds': 4, 'frame-period': 3.
         ethernetOamLinkMonCfgThreshold 1.3.6.1.4.1.11863.6.60.1.2.1.1.3 unsigned32 read-write
Enter the number of errors that is required to be equal to or greater than in order for the event to be generated.
         ethernetOamLinkMonCfgWindow 1.3.6.1.4.1.11863.6.60.1.2.1.1.4 unsigned32 read-write
Enter the period of the event. The unit is 100ms for symbol-period, frame, frame-seconds link event and 1 frame for frame-period link event.
         ethernetOamLinkMonCfgNotify 1.3.6.1.4.1.11863.6.60.1.2.1.1.5 integer read-write
Select to enable or disable the event notification. Enumeration: 'enable': 1, 'disable': 0.
         ethernetOamLinkMonCfgLAG 1.3.6.1.4.1.11863.6.60.1.2.1.1.6 octet string read-only
Displays the LAG number of the port.