Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
toshiba | 1.3.6.1.4.1.186 | |||
equ | 1.3.6.1.4.1.186.1 | |||
equUPS | 1.3.6.1.4.1.186.1.19 | |||
ticUPS | 1.3.6.1.4.1.186.1.19.2 | |||
rmti3 | 1.3.6.1.4.1.186.1.19.2.3 | |||
upsIdent | 1.3.6.1.4.1.186.1.19.2.3.1 | |||
upsIdentManufacturer | 1.3.6.1.4.1.186.1.19.2.3.1.1 | displaystring | read-only |
The name of the UPS manufacturer. |
upsIdentTypeform | 1.3.6.1.4.1.186.1.19.2.3.1.2 | displaystring | read-only |
The UPS Typeform. |
upsIdentSerialNumber | 1.3.6.1.4.1.186.1.19.2.3.1.3 | displaystring | read-only |
The UPS Serial Number. |
upsIdentMainFirmwareVersion | 1.3.6.1.4.1.186.1.19.2.3.1.4 | displaystring | read-only |
The UPS firmware version of the main controller. |
upsIdentMainBootSectorVersion | 1.3.6.1.4.1.186.1.19.2.3.1.5 | displaystring | read-only |
The UPS boot sector version of the main controller. |
upsIdentMainBootLoaderVersion | 1.3.6.1.4.1.186.1.19.2.3.1.6 | displaystring | read-only |
The UPS Boot Loader version of the main controller. |
upsIdentJobNumber | 1.3.6.1.4.1.186.1.19.2.3.1.7 | displaystring | read-only |
The UPS Job Number. |
upsIdentTestPerson | 1.3.6.1.4.1.186.1.19.2.3.1.8 | displaystring | read-only |
The test person. |
upsIdentTestDate | 1.3.6.1.4.1.186.1.19.2.3.1.9 | displaystring | read-only |
The test date displayed as YYYYMMDD format. |
upsIdentHardwareBuildDate | 1.3.6.1.4.1.186.1.19.2.3.1.10 | displaystring | read-only |
The date that the UPS was built in YYYYMMDD format. |
upsIdentEEPROMVersion | 1.3.6.1.4.1.186.1.19.2.3.1.11 | displaystring | read-only |
The UPS Main controller's EEPROM version. |
upsIdentSysName | 1.3.6.1.4.1.186.1.19.2.3.1.12 | displaystring | read-write |
A string identifying the UPS. This object should be set by the administrator. |
upsIdentAttachedDevices | 1.3.6.1.4.1.186.1.19.2.3.1.13 | displaystring | read-write |
A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. |
upsIdentInstallationDate | 1.3.6.1.4.1.186.1.19.2.3.1.14 | displaystring | read-write |
The UPS installation date in YYYYMMDD format. |
upsInput | 1.3.6.1.4.1.186.1.19.2.3.2 | |||
upsInputPowerSupplyConfiguration | 1.3.6.1.4.1.186.1.19.2.3.2.1 | integer | read-only |
This parameter summarizes the measured and collected data describing the input power supply. Enumeration: 'volt220Hz60': 10, 'volt200Hz50': 3, 'undefined': 1, 'volt240Hz60': 8, 'volt120Hz50': 13, 'volt240Hz50': 9, 'volt230Hz60': 6, 'volt208Hz60': 4, 'volt220Hz50': 11, 'volt120Hz60': 12, 'volt230Hz50': 7, 'volt200Hz60': 2, 'volt208Hz50': 5, 'reserved1': 15, 'reserved0': 14, 'reserved2': 16. |
upsInputNumLines | 1.3.6.1.4.1.186.1.19.2.3.2.2 | integer | read-only |
The number of input lines utilized in this device. This variable indicates the number of rows in the input table. Enumeration: 'two': 2, 'one': 1. |
upsInputTable | 1.3.6.1.4.1.186.1.19.2.3.2.3 | no-access |
A list of input table entries. The number of entries is given by the value of upsInputNumLine. |
|
1.3.6.1.4.1.186.1.19.2.3.2.3.1 | no-access |
An entry containing information applicable to a particular input line. |
||
upsInputIndex | 1.3.6.1.4.1.186.1.19.2.3.2.3.1.1 | positiveinteger | no-access |
The input line identifier |
upsInputFrequency | 1.3.6.1.4.1.186.1.19.2.3.2.3.1.2 | integer | read-only |
The present input frequency to the UPS system in 1/10 of Hz. |
upsInputVoltage | 1.3.6.1.4.1.186.1.19.2.3.2.3.1.3 | integer | read-only |
The input utility line voltage in RMS volts. |
upsInputCurrent | 1.3.6.1.4.1.186.1.19.2.3.2.3.1.4 | integer | read-only |
The magnitude of the present input Current in 1/10 RMS Amp. |
upsInputActivePower | 1.3.6.1.4.1.186.1.19.2.3.2.4 | integer | read-only |
The UPS active power in Watt. -1 if value is invalid. |
upsInputApparentPower | 1.3.6.1.4.1.186.1.19.2.3.2.5 | integer | read-only |
The input apparent power in Volt-Amp. |
upsInputPowerFactor | 1.3.6.1.4.1.186.1.19.2.3.2.6 | integer | read-only |
Ratio of actual power to apparent power. -1 if value is invalid. |
upsInputRatedTable | 1.3.6.1.4.1.186.1.19.2.3.2.7 | no-access |
A list of input table entries. The number of entries is given by the value of upsInputNumLine. |
|
1.3.6.1.4.1.186.1.19.2.3.2.7.1 | no-access |
An entry containing information applicable to a particular input line. |
||
upsInputSlotIndex | 1.3.6.1.4.1.186.1.19.2.3.2.7.1.1 | positiveinteger | no-access |
The input line identifier |
upsInputRatedFrequency | 1.3.6.1.4.1.186.1.19.2.3.2.7.1.2 | integer | read-only |
The present rated input frequency of the UPS system in 1/10 of Hz. |
upsInputRatedVoltage | 1.3.6.1.4.1.186.1.19.2.3.2.7.1.3 | integer | read-write |
The magnitude of the rated input voltage in RMS volts. This is set by the administrator. |
upsInputRatedCurrent | 1.3.6.1.4.1.186.1.19.2.3.2.7.1.4 | integer | read-only |
The magnitude of the rated input current in 1/10 RMS Amp. |
upsInputOverVoltage | 1.3.6.1.4.1.186.1.19.2.3.2.8 | integer | read-only |
This is the maximum limit of the input voltage before the UPS enters the over voltage state. |
upsInputOverVoltageRecoverylevel | 1.3.6.1.4.1.186.1.19.2.3.2.9 | integer | read-only |
The over voltage recovery level. It is the limit at which the UPS returns from over voltage state. |
upsInputVoltagePercent | 1.3.6.1.4.1.186.1.19.2.3.2.10 | integer | read-only |
The input voltage displayed as a percent. |
upsInputCurrentPercent | 1.3.6.1.4.1.186.1.19.2.3.2.11 | integer | read-only |
The input current displayed as a percent. |
upsInputUnderVoltageDetectlevel | 1.3.6.1.4.1.186.1.19.2.3.2.12 | integer | read-only |
The input under voltage detection level in RMS volt. |
upsInputUnderVoltageRecoverylevel | 1.3.6.1.4.1.186.1.19.2.3.2.13 | integer | read-only |
The input under voltage recovery level in RMS volt. |
upsInputRatedActivePower | 1.3.6.1.4.1.186.1.19.2.3.2.14 | integer | read-only |
The rated input active power in Watt. |
upsInputFreqWithErr | 1.3.6.1.4.1.186.1.19.2.3.2.15 | integer | read-write |
The input frequency configuration in 1/10 Hz when detection error occurred. This is set by the administrator. Enumeration: 'hz60': 2, 'hz50': 1. |
upsOutput | 1.3.6.1.4.1.186.1.19.2.3.3 | |||
upsOutputPowerSupplyConfiguration | 1.3.6.1.4.1.186.1.19.2.3.3.1 | integer | read-only |
This parameter summarizes the measured and collected data describing the output power supply. Enumeration: 'volt220Hz60': 10, 'volt200Hz50': 3, 'undefined': 1, 'volt240Hz60': 8, 'volt120Hz50': 13, 'volt240Hz50': 9, 'volt230Hz60': 6, 'volt208Hz60': 4, 'volt220Hz50': 11, 'volt120Hz60': 12, 'volt230Hz50': 7, 'volt200Hz60': 2, 'volt208Hz50': 5, 'reserved1': 15, 'reserved0': 14, 'reserved2': 16. |
upsOutputNumLines | 1.3.6.1.4.1.186.1.19.2.3.3.2 | integer | read-only |
The number of output lines utilized in this device. This variable indicates the number of rows in the output table. Enumeration: 'two': 2, 'one': 1. |
upsOutputTable | 1.3.6.1.4.1.186.1.19.2.3.3.3 | no-access |
A list of Output table entries. The number of entries is given by the value of upsOutputNumLines. |
|
1.3.6.1.4.1.186.1.19.2.3.3.3.1 | no-access |
An entry containing information applicable to a particular Output line. |
||
upsOutputIndex | 1.3.6.1.4.1.186.1.19.2.3.3.3.1.1 | positiveinteger | no-access |
The Output line identifier. |
upsOutputFrequency | 1.3.6.1.4.1.186.1.19.2.3.3.3.1.2 | integer | read-only |
The present output frequency of the UPS system in 1/10 of Hz. |
upsOutputVoltage | 1.3.6.1.4.1.186.1.19.2.3.3.3.1.3 | integer | read-only |
The Output voltage in RMS volts. |
upsOutputCurrent | 1.3.6.1.4.1.186.1.19.2.3.3.3.1.4 | integer | read-only |
The magnitude of the present output current in 1/10 RMS Amps. |
upsOutputActivePower | 1.3.6.1.4.1.186.1.19.2.3.3.3.1.5 | integer | read-only |
The present output active power in Watt. |
upsOutputApparentPower | 1.3.6.1.4.1.186.1.19.2.3.3.3.1.6 | integer | read-only |
The output apparent power in Volt-Amp. |
upsOutputLoadPercentage | 1.3.6.1.4.1.186.1.19.2.3.3.4 | integer | read-only |
The present UPS ouput load percentage which is current percent or active power whichever greater. |
upsOutputRatedTable | 1.3.6.1.4.1.186.1.19.2.3.3.5 | no-access |
A list of Output table entries. The number of entries is given by the value of upsOutputNumLines. |
|
1.3.6.1.4.1.186.1.19.2.3.3.5.1 | no-access |
An entry containing information applicable to a particular Output line. |
||
upsOutputSlotIndex | 1.3.6.1.4.1.186.1.19.2.3.3.5.1.1 | positiveinteger | no-access |
The Output line identifier. |
upsOutputRatedFrequency | 1.3.6.1.4.1.186.1.19.2.3.3.5.1.2 | integer | read-only |
The present output rated frequency of the UPS system in 1/10 of Hz. |
upsOutputRatedVoltage | 1.3.6.1.4.1.186.1.19.2.3.3.5.1.3 | integer | read-write |
The rated output voltage in RMS volts. This is set by the administrator |
upsOutputRatedCurrent | 1.3.6.1.4.1.186.1.19.2.3.3.5.1.4 | integer | read-only |
The output rated current in 1/10 RMS Amp. |
upsOutputRatedActivePower | 1.3.6.1.4.1.186.1.19.2.3.3.5.1.5 | integer | read-only |
The output rated active power in Watt. |
upsOutputRatedApparentPower | 1.3.6.1.4.1.186.1.19.2.3.3.5.1.6 | integer | read-only |
The output rated apparent power in Volt-Amp. |
upsOutputUndervoltagelevel | 1.3.6.1.4.1.186.1.19.2.3.3.6 | integer | read-only |
This parameter displays the minimum allowable voltage before it falls into under voltage range. |
upsOutputOverVoltagelevel | 1.3.6.1.4.1.186.1.19.2.3.3.7 | integer | read-only |
This is the maximum limit of the output voltage before the UPS enters the over voltage state. |
upsOutputFrequencySynchRange | 1.3.6.1.4.1.186.1.19.2.3.3.8 | nonnegativeinteger | read-only |
The allowable range for synchronizing output frequency in 1/10 of Hz. |
upsOutputVoltageAdjust | 1.3.6.1.4.1.186.1.19.2.3.3.9 | integer | read-write |
This parameter allows UPS to be configured to have adjustable voltages. This is set by the administrator. |
upsOutputRatedPowerFactor | 1.3.6.1.4.1.186.1.19.2.3.3.10 | integer | read-only |
The rated output power factor. |
upsBypass | 1.3.6.1.4.1.186.1.19.2.3.4 | |||
upsBypassPowerSupplyConfiguration | 1.3.6.1.4.1.186.1.19.2.3.4.1 | integer | read-only |
This parameter summarizes the measured and collected data describing the power supply into the bypass circuit. Enumeration: 'volt220Hz60': 10, 'volt200Hz50': 3, 'undefined': 1, 'volt240Hz60': 8, 'volt120Hz50': 13, 'volt240Hz50': 9, 'volt230Hz60': 6, 'volt208Hz60': 4, 'volt220Hz50': 11, 'volt120Hz60': 12, 'volt230Hz50': 7, 'volt200Hz60': 2, 'volt208Hz50': 5, 'reserved1': 15, 'reserved0': 14, 'reserved2': 16. |
upsBypassNumLine | 1.3.6.1.4.1.186.1.19.2.3.4.2 | integer | read-only |
The number of bypass lines utilized in this device. This variable indicates the number of rows in the bypass table. Enumeration: 'two': 2, 'one': 1. |
upsBypassTable | 1.3.6.1.4.1.186.1.19.2.3.4.3 | no-access |
A list of Bypass table entries. The number of entries is given by the value of upsBypassNumLines. |
|
1.3.6.1.4.1.186.1.19.2.3.4.3.1 | no-access |
An entry containing information applicable to a particular line. |
||
upsBypassIndex | 1.3.6.1.4.1.186.1.19.2.3.4.3.1.1 | positiveinteger | no-access |
The Bypass line identifier. |
upsBypassFrequency | 1.3.6.1.4.1.186.1.19.2.3.4.3.1.2 | integer | read-only |
The present Bypass frequency of the UPS system in 1/10 of Hz of each phase. |
upsBypassVoltage | 1.3.6.1.4.1.186.1.19.2.3.4.3.1.3 | integer | read-only |
The Bypass utility line voltage in RMS volts. |
upsBypassCurrent | 1.3.6.1.4.1.186.1.19.2.3.4.3.1.4 | integer | read-only |
The magnitude of the present bypass Current in 1/10 RMS Amp. |
upsBypassApparentPower | 1.3.6.1.4.1.186.1.19.2.3.4.4 | integer | read-only |
The Bypass Apparent power in Volt-Amp. |
upsBypassUnderVoltageDetectionlevel | 1.3.6.1.4.1.186.1.19.2.3.4.5 | integer | read-only |
This parameter displays the minimum allowable voltage before it falls into bypass undervoltage range. |
upsBypassUnderVoltageRecoverylevel | 1.3.6.1.4.1.186.1.19.2.3.4.6 | integer | read-only |
This parameter displays the allowable voltage that it can recover from. |
upsBypassOverVoltageDetectionlevel | 1.3.6.1.4.1.186.1.19.2.3.4.7 | integer | read-only |
This parameter displays the maximum allowable voltage before it falls into over voltage range. |
upsBypassOverVoltageRecoverylevel | 1.3.6.1.4.1.186.1.19.2.3.4.8 | integer | read-only |
This parameter displays the allowable voltage that it can recover from. |
upsDCBus | 1.3.6.1.4.1.186.1.19.2.3.5 | |||
upsDCBusTotalVoltage | 1.3.6.1.4.1.186.1.19.2.3.5.1 | integer | read-only |
The DC Bus voltage in DC volts. |
upsDCBusPositiveVoltage | 1.3.6.1.4.1.186.1.19.2.3.5.2 | integer | read-only |
The DC Bus positive voltage in DC volts. |
upsDCBusNegativeVoltage | 1.3.6.1.4.1.186.1.19.2.3.5.3 | integer | read-only |
The DC Bus negative voltage in DC volts. |
upsDCBusRatedVoltage | 1.3.6.1.4.1.186.1.19.2.3.5.4 | integer | read-only |
The DC Bus rated voltage in DC volts. |
upsBattery | 1.3.6.1.4.1.186.1.19.2.3.6 | |||
upsBatteryStatus | 1.3.6.1.4.1.186.1.19.2.3.6.1 | integer | read-only |
The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time sufficient to handle the load. A value of batteryLow indicates the battery level is low. Continued operation in battery mode will deplate batteries. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output). A value of batteryDischarging indicates UPS system is in Battery power. Enumeration: 'unknown': 1, 'batteryDepleted': 4, 'batteryFailure': 6, 'batteryNormal': 2, 'batteryLow': 3, 'batteryDischarging': 5. |
upsSecondsOnBattery | 1.3.6.1.4.1.186.1.19.2.3.6.2 | nonnegativeinteger | read-only |
If the unit is on battery power, the elapsed time since the UPS on battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power. |
upsBatteryVoltage | 1.3.6.1.4.1.186.1.19.2.3.6.3 | integer | read-only |
The magnitude of the present battery voltage in DC Volt. |
upsBatteryDischargeCurrent | 1.3.6.1.4.1.186.1.19.2.3.6.4 | integer | read-only |
The present battery discharge current in 1/10 DC Amp. |
upsBatteryChargeStatus | 1.3.6.1.4.1.186.1.19.2.3.6.5 | integer | read-only |
The UPS charger status. Enumeration: 'normal-charging': 1, 'preventative-charging': 2, 'stop-charging': 3. |
upsBatteryNumberofDischarge | 1.3.6.1.4.1.186.1.19.2.3.6.6 | nonnegativeinteger | read-only |
This will increment when ups goes into backup mode which is longer than 10 seconds. |
upsBatteryCalculatedShutdownVoltage | 1.3.6.1.4.1.186.1.19.2.3.6.7 | integer | read-only |
The battery's shutdown voltage in DC Volt. |
upsBatteryLifeRemaining | 1.3.6.1.4.1.186.1.19.2.3.6.8 | nonnegativeinteger | read-only |
The number of hours of UPS operation in the present environment until the batteries must be replaced. |
upsBatteryRatedAmpereHour | 1.3.6.1.4.1.186.1.19.2.3.6.9 | integer | read-only |
The battery capacity in Amp-Hour. |
upsBatteryInSeries | 1.3.6.1.4.1.186.1.19.2.3.6.10 | integer | read-only |
The number of batteries in each string connected in series. |
upsBatteryInParallel | 1.3.6.1.4.1.186.1.19.2.3.6.11 | integer | read-only |
The number of batteries connected in parallel. |
upsBatteryInstallationDate | 1.3.6.1.4.1.186.1.19.2.3.6.12 | displaystring | read-only |
The battery installation date in YYYYMMDD format. |
upsBatteryVoltageShutdownLevel | 1.3.6.1.4.1.186.1.19.2.3.6.13 | integer | read-only |
The UPS battery voltage shutdown level. |
upsBatteryExtTable | 1.3.6.1.4.1.186.1.19.2.3.6.14 | no-access |
A list of Battery table entries. |
|
1.3.6.1.4.1.186.1.19.2.3.6.14.1 | no-access |
An entry containing information applicable to a particular Battery. |
||
upsBatteryExtIndex | 1.3.6.1.4.1.186.1.19.2.3.6.14.1.1 | positiveinteger | no-access |
The Battery line identifier |
upsBatteryExtInSeries | 1.3.6.1.4.1.186.1.19.2.3.6.14.1.2 | integer | read-only |
Specifies the number of batteries in the external cabinet that are connected in series. |
upsBatteryExtInParallel | 1.3.6.1.4.1.186.1.19.2.3.6.14.1.3 | integer | read-only |
Specifies the number of batteries in the external cabinet that are connected in parallel. |
upsBatteryExtRatedAmpereHour | 1.3.6.1.4.1.186.1.19.2.3.6.14.1.4 | integer | read-only |
The external battery's capacity in Amp-Hour. |
upsBatteryExtCRate | 1.3.6.1.4.1.186.1.19.2.3.6.14.1.5 | integer | read-only |
The external battery's C rate. |
upsBatteryExtInstallDate | 1.3.6.1.4.1.186.1.19.2.3.6.14.1.6 | displaystring | read-only |
The battery installation date in YYYYMMDD format. |
upsBatteryLowBattLevel | 1.3.6.1.4.1.186.1.19.2.3.6.15 | integer | read-only |
The low battery level of the UPS. |
upsBatteryChargerOverVoltageDelay | 1.3.6.1.4.1.186.1.19.2.3.6.16 | integer | read-only |
The UPS's charger over voltage detection delay in seconds. |
upsBatteryCalcLBLevel | 1.3.6.1.4.1.186.1.19.2.3.6.17 | integer | read-only |
The calculated low battery level. |
upsBatteryCapacity | 1.3.6.1.4.1.186.1.19.2.3.6.18 | integer | read-only |
The UPS battery capacity in percent. |
upsBatteryRuntime | 1.3.6.1.4.1.186.1.19.2.3.6.19 | integer | read-only |
The UPS battery runtime in minutes. It will return -1 or N/A if not available. |
upsStsCtlCfg | 1.3.6.1.4.1.186.1.19.2.3.7 | |||
upsStsCtlCfgSystemTemperature | 1.3.6.1.4.1.186.1.19.2.3.7.1 | integer | read-only |
The UPS system temperature in Celsius. |
upsStsCtlCfgBatteryTemperature | 1.3.6.1.4.1.186.1.19.2.3.7.2 | integer | read-only |
The UPS Battery temperature in Celsius. |
upsStsCtlCfgPresentMode | 1.3.6.1.4.1.186.1.19.2.3.7.3 | integer | read-only |
The present mode of the UPS system. Enumeration: 'bypass7': 8, 'shutdown2': 3, 'shutdown1': 2, 'shutdown0': 1, 'bypass6': 7, 'startup': 10, 'bypass8': 9, 'battery-test': 6, 'online': 4, 'backup': 5. |
upsStsCtlCfgModeRequest | 1.3.6.1.4.1.186.1.19.2.3.7.4 | integer | read-write |
The mode of the UPS system requested by the user. Enumeration: 'battery-test': 5, 'none': 1, 'shutdown': 2, 'bypass': 3, 'online': 4. |
upsStsCtlCfgModeTransitionTimer | 1.3.6.1.4.1.186.1.19.2.3.7.5 | nonnegativeinteger | read-write |
The timer upon whose expiration a mode transition will be attempted by the system. |
upsStsCtlCfgEPOContactState | 1.3.6.1.4.1.186.1.19.2.3.7.6 | integer | read-only |
The EPO contact state of the UPS system. Enumeration: 'open': 1, 'closed': 2. |
upsStsCtlCfgRunStopSwitchState | 1.3.6.1.4.1.186.1.19.2.3.7.7 | integer | read-only |
The Run/Stop switch state of the UPS system. Enumeration: 'stop': 1, 'run': 2. |
upsStsCtlCfgServicePortCommStatus | 1.3.6.1.4.1.186.1.19.2.3.7.8 | integer | read-only |
The service port communication status. Enumeration: 'unknown': 1, 'off': 3, 'normal-OK': 2, 'error': 4. |
upsStsCtlCfgInternalCommStatus | 1.3.6.1.4.1.186.1.19.2.3.7.9 | integer | read-only |
The internal communication status of the UPS system such as display panel. Enumeration: 'unknown': 1, 'off': 3, 'normal-OK': 2, 'error': 4. |
upsStsCtlCfgSecurityLevel | 1.3.6.1.4.1.186.1.19.2.3.7.10 | displaystring | read-write |
The current security level of the UPS system |
upsStsCtlCfgPresentDate | 1.3.6.1.4.1.186.1.19.2.3.7.11 | nonnegativeinteger | read-write |
The present date of the UPS. This is configurable by Administrator. |
upsStsCtlCfgPresentTime | 1.3.6.1.4.1.186.1.19.2.3.7.12 | nonnegativeinteger | read-write |
The present time of the UPS. This is configurable by Administrator. |
upsStsCtlCfgPresentTimeStamp | 1.3.6.1.4.1.186.1.19.2.3.7.13 | integer | read-only |
Present system timestamp. |
upsStsCtlCfgEnableRMTIToControlMode | 1.3.6.1.4.1.186.1.19.2.3.7.14 | integer | read-write |
Allow to enable or disable SNMP to control the UPS Shutdown and Online Mode. Enumeration: 'enable': 2, 'disable': 1. |
upsStsCtlCfgEnableStartupDelay | 1.3.6.1.4.1.186.1.19.2.3.7.15 | integer | read-write |
This delay timer, when enabled, will begin counting down at UPS startup immediately following a UPS shutdown by any means other than battery exhaustion. UPS output of any kind will be prohibited. Enumeration: 'enable': 2, 'disable': 1. |
upsStsCtlCfgStartUpDelayMode | 1.3.6.1.4.1.186.1.19.2.3.7.16 | integer | read-write |
UPS mode into which the UPS will transition at the expiration of the Start-Up delay timer. Enumeration: 'bypass': 1, 'online': 2. |
upsStsCtlCfgStartUpDelay | 1.3.6.1.4.1.186.1.19.2.3.7.17 | nonnegativeinteger | read-write |
When the timer is counting down, its changing value is reflected, otherwise its starting value is reported. |
upsStsCtlCfgRemoteShutDownContactState | 1.3.6.1.4.1.186.1.19.2.3.7.18 | integer | read-only |
The state of the Remote Contacts Shutdown Control. Enumeration: 'open': 1, 'closed': 2. |
upsStsCtlCfgRemoteShutdownContactMode | 1.3.6.1.4.1.186.1.19.2.3.7.19 | integer | read-write |
The mode of the Remote Contacts Shutdown control. Enumeration: 'shutdown-while-contact-closed': 2, 'bypass': 1. |
upsStsCtlCfgEnableDryContactLANShutdown | 1.3.6.1.4.1.186.1.19.2.3.7.20 | integer | read-write |
When enable, UPS will accept LAN signal request for UPS shutdown but only in accordance with restrictions of the following timer. Enumeration: 'enable': 2, 'disable': 1. |
upsStsCtlCfgDryContactLANShutdownTimer | 1.3.6.1.4.1.186.1.19.2.3.7.21 | nonnegativeinteger | read-write |
Timer begins upon input power recovery and during its lifetime, allows the LAN input signal to affect a UPS Shutdown control. |
upsStsCtlCfgDryContactOnBattDelay | 1.3.6.1.4.1.186.1.19.2.3.7.22 | nonnegativeinteger | read-write |
Time delay between actual event occurrence and dry contact closure to signal external devices of the event. |
upsStsCtlCfgDryContactLowBattDelay | 1.3.6.1.4.1.186.1.19.2.3.7.23 | nonnegativeinteger | read-write |
Delay timer between actual event occurrence and dry contact closure to signal external devices of the event. |
upsStsCtlCfgEnableStartupBattTest | 1.3.6.1.4.1.186.1.19.2.3.7.24 | integer | read-write |
Forces a battery test when UPS starts. Enumeration: 'enable': 2, 'disable': 1. |
upsStsCtlCfgEnableBatteryTest | 1.3.6.1.4.1.186.1.19.2.3.7.25 | integer | read-write |
Allow to enable or disable battery test. Enumeration: 'enable': 2, 'disable': 1. |
upsStsCtlCfgBatteryTestConditionStatus | 1.3.6.1.4.1.186.1.19.2.3.7.26 | integer | read-only |
This notifies the user of the availability of the battery test feature. Enumeration: 'battery-test-ok': 2, 'battery-test-prohibited': 1. |
upsStsCtlCfgMaxBatteryTestFreq | 1.3.6.1.4.1.186.1.19.2.3.7.27 | integer | read-write |
This specified how often the battery test should occur. This is set by the administrator Enumeration: 'monthly': 3, 'daily': 1, 'weekly': 2. |
upsStsCtlCfgEnableRestartAfterBattShutdown | 1.3.6.1.4.1.186.1.19.2.3.7.28 | integer | read-write |
Mode set for UPS input power detection immediately after a shutdown while on batteries. This is set by the administrator. Enumeration: 'enable': 2, 'disable': 1. |
upsStsCtlCfgRestartDelay | 1.3.6.1.4.1.186.1.19.2.3.7.29 | integer | read-write |
Countdown begins only when UPS input power is restored immediately following a UPS Shutdown while on batteries. |
upsStsCtlCfgEnableAutoTransferMode | 1.3.6.1.4.1.186.1.19.2.3.7.30 | integer | read-write |
This feature allows the administrators to enable or to disable the auto transfer feature of the UPS. Enumeration: 'enable': 2, 'disable': 1. |
upsStsCtlCfgAutoRetransferDelay | 1.3.6.1.4.1.186.1.19.2.3.7.31 | integer | read-write |
Time period to wait after fault occurrence before attempting transfer back Online |
upsStsCtlCfgServicePortCommSetting | 1.3.6.1.4.1.186.1.19.2.3.7.32 | integer | read-write |
The UPS baud rate settings. Enumeration: 'bd19200': 2, 'bd57600': 4, 'bd9600': 1, 'bd38400': 3. |
upsStsCtlCfgInvertRemoteShutdownLogic | 1.3.6.1.4.1.186.1.19.2.3.7.33 | integer | read-write |
Remote Shutdown logic. Enumeration: 'not-inverted': 1, 'inverted': 2. |
upsStsCtlCfgRestartMode | 1.3.6.1.4.1.186.1.19.2.3.7.34 | integer | read-write |
Restart Mode. Enumeration: 'bypass': 1, 'online': 2. |
upsHistory | 1.3.6.1.4.1.186.1.19.2.3.8 | |||
upsHistorySysOperationTime | 1.3.6.1.4.1.186.1.19.2.3.8.1 | nonnegativeinteger | read-only |
The amount of time the UPS has been on. |
upsHistoryInverterOperationTime | 1.3.6.1.4.1.186.1.19.2.3.8.2 | nonnegativeinteger | read-only |
The amount of time the UPS has been in On-Line Mode. |
upsHistoryBackupOperationTime | 1.3.6.1.4.1.186.1.19.2.3.8.3 | nonnegativeinteger | read-only |
The amount of time the UPS has been in BackUp Mode. |
upsHistoryLifetimeRemaining | 1.3.6.1.4.1.186.1.19.2.3.8.4 | nonnegativeinteger | read-only |
The remaining lifetime of the UPS. |
upsHistoryHighestSystemTemp | 1.3.6.1.4.1.186.1.19.2.3.8.5 | integer | read-only |
The highest system temperature of the UPS. |
upsHistoryHighestBatteryTemp | 1.3.6.1.4.1.186.1.19.2.3.8.6 | integer | read-only |
The highest battery temperature. |
upsHistoryTotalNumInputUnderVolt | 1.3.6.1.4.1.186.1.19.2.3.8.7 | nonnegativeinteger | read-only |
Total number of times the UPS has entered under voltage state. |
upsHistoryTotalNumOverload | 1.3.6.1.4.1.186.1.19.2.3.8.8 | nonnegativeinteger | read-only |
Total number of times the UPS has been overloaded. |
upsHistoryTotalNumTest | 1.3.6.1.4.1.186.1.19.2.3.8.9 | nonnegativeinteger | read-only |
Total number of tests that has been conducted on the UPS. |
upsHistoryTotalNumBackup | 1.3.6.1.4.1.186.1.19.2.3.8.10 | nonnegativeinteger | read-only |
Total number of times the UPS has been in Back-Up mode. |
upsHistoryTotalNumFaults | 1.3.6.1.4.1.186.1.19.2.3.8.11 | nonnegativeinteger | read-only |
Total number of faults that has occurred on the UPS. |
upsHistoryTotalNumOperationModeChange | 1.3.6.1.4.1.186.1.19.2.3.8.12 | nonnegativeinteger | read-only |
The number of mode changes that has occurred. |
upsHistoryTotalNumWarnings | 1.3.6.1.4.1.186.1.19.2.3.8.13 | nonnegativeinteger | read-only |
The number of warnings that has occurred on the UPS. |
upsHistoryTotalNumSystemSettingsChanged | 1.3.6.1.4.1.186.1.19.2.3.8.14 | nonnegativeinteger | read-only |
The number of times the System settings have been changed. |
upsHistoryTotalNumResets | 1.3.6.1.4.1.186.1.19.2.3.8.15 | nonnegativeinteger | read-only |
The number of times the UPS has reset. |
upsDisplay | 1.3.6.1.4.1.186.1.19.2.3.9 | |||
upsDisplayFirmwareVersion | 1.3.6.1.4.1.186.1.19.2.3.9.1 | displaystring | read-only |
The firmware version of the display. |
upsDisplayBootSectorVersion | 1.3.6.1.4.1.186.1.19.2.3.9.2 | displaystring | read-only |
The boot sector version of the display. |
upsDisplayBootLoaderVersion | 1.3.6.1.4.1.186.1.19.2.3.9.3 | displaystring | read-only |
The boot loader version of the display. |
upsDisplaySleepTimer | 1.3.6.1.4.1.186.1.19.2.3.9.4 | nonnegativeinteger | read-write |
The sleep timer for the display. |
upsDisplayBuzzerMode | 1.3.6.1.4.1.186.1.19.2.3.9.5 | integer | read-write |
Configures buzzer mode. Enumeration: 'enable': 2, 'disable': 1. |
upsDisplayBuzzerStatus | 1.3.6.1.4.1.186.1.19.2.3.9.6 | integer | read-only |
Shows the current state of the buzzer. Enumeration: 'sound': 3, 'idle': 2, 'off': 1, 'silenced': 4. |
upsDisplayRMTIInstallDate | 1.3.6.1.4.1.186.1.19.2.3.9.7 | displaystring | read-only |
The RMTI installation date. |
upsDisplayRMTIInstallStatus | 1.3.6.1.4.1.186.1.19.2.3.9.8 | integer | read-only |
Shows the installation status of the RMTI. Enumeration: 'uninstalled': 1, 'installed': 2. |
upsDisplayRMTIBaudRate | 1.3.6.1.4.1.186.1.19.2.3.9.9 | integer | read-only |
Configures the baud rate. Enumeration: 'bd19200': 2, 'bd57600': 4, 'bd9600': 1, 'bd38400': 3. |
upsDisplayRMTIDataLink | 1.3.6.1.4.1.186.1.19.2.3.9.10 | integer | read-only |
Shows the data status of the RMTI. Enumeration: 'link-down': 2, 'unknown': 1, 'link-up': 3. |
upsDisplayRMTINetworkLink | 1.3.6.1.4.1.186.1.19.2.3.9.11 | integer | read-only |
Shows the network status of the RMTI. Enumeration: 'link-down': 2, 'unknown': 1, 'link-up': 3. |
upsAlarm | 1.3.6.1.4.1.186.1.19.2.3.10 | |||
upsAlarmsPresent | 1.3.6.1.4.1.186.1.19.2.3.10.1 | gauge32 | read-only |
The present number of active alarm conditions. |
upsAlarmTable | 1.3.6.1.4.1.186.1.19.2.3.10.2 | no-access |
A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an OBJECT IDENTIFIER, upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent. |
|
1.3.6.1.4.1.186.1.19.2.3.10.2.1 | no-access |
An entry containing information applicable to a particular alarm. |
||
upsAlarmId | 1.3.6.1.4.1.186.1.19.2.3.10.2.1.1 | positiveinteger | no-access |
An unique identifier for an alarm condition. This value must remain constant. |
upsAlarmDescr | 1.3.6.1.4.1.186.1.19.2.3.10.2.1.2 | autonomoustype | read-only |
A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. |
upsAlarmTime | 1.3.6.1.4.1.186.1.19.2.3.10.2.1.3 | timestamp | read-only |
The value of upsConfigSystemTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0. |
upsWellKnownAlarms | 1.3.6.1.4.1.186.1.19.2.3.10.3 | |||
upsAlarmFault | 1.3.6.1.4.1.186.1.19.2.3.10.3.1 | integer | read-only |
Fault: One or more fault reported. |
upsAlarmOpenFuse | 1.3.6.1.4.1.186.1.19.2.3.10.3.2 | integer | read-only |
Fault: An open fuse reported. |
upsAlarmCurrentLimitFault | 1.3.6.1.4.1.186.1.19.2.3.10.3.3 | integer | read-only |
Fault: A current limit reported. |
upsAlarmDCBusOverCurrent | 1.3.6.1.4.1.186.1.19.2.3.10.3.4 | integer | read-only |
Fault: A DC bus overcurrent reported. |
upsAlarmDCOverVoltage | 1.3.6.1.4.1.186.1.19.2.3.10.3.5 | integer | read-only |
Fault: A DC bus overvoltage repoprted. |
upsAlarmDCBusImbalance | 1.3.6.1.4.1.186.1.19.2.3.10.3.6 | integer | read-only |
Fault: A DC bus imbalance reported. |
upsAlarmOutputUnderVoltage | 1.3.6.1.4.1.186.1.19.2.3.10.3.7 | integer | read-only |
Fault: An inverter output undervoltage reported. |
upsAlarmOutputOverVoltage | 1.3.6.1.4.1.186.1.19.2.3.10.3.8 | integer | read-only |
Fault: An inverter output overvoltage reported. |
upsAlarmHeatSinkOverheat | 1.3.6.1.4.1.186.1.19.2.3.10.3.9 | integer | read-only |
Fault: Heat sink or device overheat reported. |
upsAlarmBypassOverload | 1.3.6.1.4.1.186.1.19.2.3.10.3.10 | integer | read-only |
Fault: A bypass overload reported. |
upsAlarmChargerOverVoltageFault | 1.3.6.1.4.1.186.1.19.2.3.10.3.11 | integer | read-only |
Fault: Charger overvoltage reported. |
upsAlarmOutputOverCurrent | 1.3.6.1.4.1.186.1.19.2.3.10.3.12 | integer | read-only |
Fault: A output overcurrent reported. |
upsAlarmDCUnderVoltAtBoostUp | 1.3.6.1.4.1.186.1.19.2.3.10.3.13 | integer | read-only |
Fault: A DC bus undervoltage reported during DC bus boost-up. |
upsAlarmDCUnderVoltAtCharge | 1.3.6.1.4.1.186.1.19.2.3.10.3.14 | integer | read-only |
Fault: A DC bus undervoltage during DC bus charging reported. |
upsAlarmBypassOverheat | 1.3.6.1.4.1.186.1.19.2.3.10.3.15 | integer | read-only |
Fault: A bypass Overheat reported. |
upsAlarmResettableInverterOverload | 1.3.6.1.4.1.186.1.19.2.3.10.3.16 | integer | read-only |
Fault: An inverter overload reported. It is resetable. |
upsAlarmUnresettableInverterOverload | 1.3.6.1.4.1.186.1.19.2.3.10.3.17 | integer | read-only |
Fault: An inverter overload reported. It is not resetable. |
upsAlarmInputOverVoltage | 1.3.6.1.4.1.186.1.19.2.3.10.3.18 | integer | read-only |
Warning: An input overvoltage reported. |
upsAlarmInputUnderVoltage | 1.3.6.1.4.1.186.1.19.2.3.10.3.19 | integer | read-only |
Warning: An input undervoltage reported. |
upsAlarmInputFrequencyError | 1.3.6.1.4.1.186.1.19.2.3.10.3.20 | integer | read-only |
Warning: An input frequency error reported. |
upsAlarmBypassOverVoltage | 1.3.6.1.4.1.186.1.19.2.3.10.3.21 | integer | read-only |
Warning: A bypass overvoltage reported. |
upsAlarmBypassUnderVoltage | 1.3.6.1.4.1.186.1.19.2.3.10.3.22 | integer | read-only |
Warning: A bypass undervoltage reported. |
upsAlarmBypassFrequencyError | 1.3.6.1.4.1.186.1.19.2.3.10.3.23 | integer | read-only |
Warning: An bypass frequency error reported. |
upsAlarmDCBusUnderVoltAtBattTest | 1.3.6.1.4.1.186.1.19.2.3.10.3.24 | integer | read-only |
Warning: A DC bus undervoltage reported during battery test |
upsAlarmBatteryLow | 1.3.6.1.4.1.186.1.19.2.3.10.3.25 | integer | read-only |
Warning: A Low battery reported. |
upsAlarmBatteryAtShutdownlevel | 1.3.6.1.4.1.186.1.19.2.3.10.3.26 | integer | read-only |
Warning: A Battery shutdown voltage level reported. |
upsAlarmReplaceBattery | 1.3.6.1.4.1.186.1.19.2.3.10.3.27 | integer | read-only |
Warning: Batteries are in need of replacement. |
upsAlarmChargerOverVoltageWarning | 1.3.6.1.4.1.186.1.19.2.3.10.3.28 | integer | read-only |
Warning: Charger overvoltage reported. |
upsAlarmBatteryTestFailed | 1.3.6.1.4.1.186.1.19.2.3.10.3.29 | integer | read-only |
Warning: A battery test failed event reported. |
upsAlarmBatteryDepleted | 1.3.6.1.4.1.186.1.19.2.3.10.3.30 | integer | read-only |
Warning: A battery depleted event reported. It will not be able to support critical loads. |
upsAlarmBatteryOverheat | 1.3.6.1.4.1.186.1.19.2.3.10.3.31 | integer | read-only |
Warning: A Battery overheat reported. |
upsAlarmSystemOverheat | 1.3.6.1.4.1.186.1.19.2.3.10.3.32 | integer | read-only |
Warning: A system overheat reported. |
upsAlarmOutputOverloadWarning | 1.3.6.1.4.1.186.1.19.2.3.10.3.33 | integer | read-only |
Warning: An inverter output overload reported. UPS will switch to bypass operation or shut down if no action is taken. Shut down excess equipment to reduce Load. |
upsAlarmCurrentLimitWarning | 1.3.6.1.4.1.186.1.19.2.3.10.3.34 | integer | read-only |
Warning: A current limit reported. |
upsAlarmAsyncOperation | 1.3.6.1.4.1.186.1.19.2.3.10.3.35 | integer | read-only |
Warning: An Asynchronous operation reported. |
upsAlarmServiceUPS | 1.3.6.1.4.1.186.1.19.2.3.10.3.36 | integer | read-only |
Warning: UPS is in need of service. Please contact authorized Toshiba service center for assistance. |
upsAlarmBatteryNearExpiration | 1.3.6.1.4.1.186.1.19.2.3.10.3.37 | integer | read-only |
Warning: Batteries are nearing the end of their expected lifetime. |
upsAlarmBatteryExpired | 1.3.6.1.4.1.186.1.19.2.3.10.3.38 | integer | read-only |
Warning: Batteries have reached their expected lifetime. |
upsAlarmDisplayCableError | 1.3.6.1.4.1.186.1.19.2.3.10.3.39 | integer | read-only |
Warning: A display cable error reported. |
upsAlarmRemotEyeCommError | 1.3.6.1.4.1.186.1.19.2.3.10.3.40 | integer | read-only |
Warning: A Communication error between the main control and the RemotEye reported. |
upsAlarmRemotEyeUplinkCommError | 1.3.6.1.4.1.186.1.19.2.3.10.3.41 | integer | read-only |
Warning: A communication error between the RemotEye III and the network reported. |
upsAlarmServicePortCommError | 1.3.6.1.4.1.186.1.19.2.3.10.3.42 | integer | read-only |
Warning: A communication error between the main controller and the service communication port reported. |
upsAlarmDispCommError | 1.3.6.1.4.1.186.1.19.2.3.10.3.43 | integer | read-only |
Warning: A communication error between the main controller and display controller reported. |
upsAlarmSystemTestFailed | 1.3.6.1.4.1.186.1.19.2.3.10.3.44 | integer | read-only |
Warning: A system test failed event reported. |
upsAlarmBypassOn | 1.3.6.1.4.1.186.1.19.2.3.10.3.45 | integer | read-only |
Warning: The UPS is in Stop (Bypass) mode |
upsAlarmPowerFailure | 1.3.6.1.4.1.186.1.19.2.3.10.3.46 | integer | read-only |
Info: A power failure reported. |
upsAlarmShutdownPending | 1.3.6.1.4.1.186.1.19.2.3.10.3.47 | integer | read-only |
Info: An output shutdown in progress reported. Output will turn off after delay. |
upsAlarmOutputOffAsRequested | 1.3.6.1.4.1.186.1.19.2.3.10.3.48 | integer | read-only |
Info: An output shutdown mode requested. |
upsAlarmOutputOff | 1.3.6.1.4.1.186.1.19.2.3.10.3.49 | integer | read-only |
Info: An output off reported. |
upsAlarmBatteryTestInProgress | 1.3.6.1.4.1.186.1.19.2.3.10.3.50 | integer | read-only |
Info: A battery test in progress reported. |
upsAlarmBatteryOn | 1.3.6.1.4.1.186.1.19.2.3.10.3.51 | integer | read-only |
Info: The UPS is on Battery mode; it is supplying output power from its batteries. |
upsAlarmEMDSensor1AlarmTriggered | 1.3.6.1.4.1.186.1.19.2.3.10.3.52 | integer | read-only |
Info: EMD sensor 1 alarm is triggered. |
upsAlarmEMDSensor2AlarmTriggered | 1.3.6.1.4.1.186.1.19.2.3.10.3.53 | integer | read-only |
Info: EMD sensor 2 alarm is triggered. |
upsAlarmEMDHumidityAtLowCriticalPoint | 1.3.6.1.4.1.186.1.19.2.3.10.3.54 | integer | read-only |
Info: EMD humidity is at low critical point. |
upsAlarmEMDHumidityAtHighCriticalPoint | 1.3.6.1.4.1.186.1.19.2.3.10.3.55 | integer | read-only |
Info: EMD humidity is at high critical point. |
upsAlarmEMDHumidityAtLowWarningPoint | 1.3.6.1.4.1.186.1.19.2.3.10.3.56 | integer | read-only |
Info: EMD humidity is at low warning point. |
upsAlarmEMDHumidityAtHighWarningPoint | 1.3.6.1.4.1.186.1.19.2.3.10.3.57 | integer | read-only |
Info: EMD humidity is at high warning point. |
upsAlarmEMDTemperatureAtLowCriticalPoint | 1.3.6.1.4.1.186.1.19.2.3.10.3.58 | integer | read-only |
Info: EMD Temperature is at low critical point. |
upsAlarmEMDTemperatureAtHighCriticalPoint | 1.3.6.1.4.1.186.1.19.2.3.10.3.59 | integer | read-only |
Info: EMD Temperature is at high critical point. |
upsAlarmEMDTemperatureAtLowWarningPoint | 1.3.6.1.4.1.186.1.19.2.3.10.3.60 | integer | read-only |
Info: EMD Temperature is at low warning point. |
upsAlarmEMDTemperatureAtHighWarningPoint | 1.3.6.1.4.1.186.1.19.2.3.10.3.61 | integer | read-only |
Info: EMD Temperature is at high warning point. |
upsAlarmLogInError | 1.3.6.1.4.1.186.1.19.2.3.10.3.62 | integer | read-only |
Info: Username/Password information is incorrect. |
upsPassword | 1.3.6.1.4.1.186.1.19.2.3.11 | |||
upsPwdAdminCurrentAccessLevel | 1.3.6.1.4.1.186.1.19.2.3.11.1 | displaystring | read-only |
The administrator access level. |
upsPwdAdminCurrentLogin | 1.3.6.1.4.1.186.1.19.2.3.11.2 | displaystring | read-write |
The administrator access login name. |
upsPwdAdminNewLoginAccess | 1.3.6.1.4.1.186.1.19.2.3.11.3 | displaystring | read-write |
The administrator access login name. |
upsPwdAdminCurrentPswd | 1.3.6.1.4.1.186.1.19.2.3.11.4 | displaystring | read-write |
The current password. |
upsPwdAdminNewPswd | 1.3.6.1.4.1.186.1.19.2.3.11.5 | displaystring | read-write |
The current password. |
upsAgent | 1.3.6.1.4.1.186.1.19.2.3.12 | |||
upsAgentSoftwareVersion | 1.3.6.1.4.1.186.1.19.2.3.12.1 | displaystring | read-only |
The RemotEye III version number |
upsAgentHardwareAddress | 1.3.6.1.4.1.186.1.19.2.3.12.2 | displaystring | read-only |
The hardware/MAC address that NMS can identify the managed device |
upsAgentIPAddress | 1.3.6.1.4.1.186.1.19.2.3.12.3 | ipaddress | read-write |
The ip address that NMS can identify the managed device |
upsAgentGatewayAddress | 1.3.6.1.4.1.186.1.19.2.3.12.4 | ipaddress | read-write |
The default gateway that allow device managed through routers |
upsAgentSubnetMask | 1.3.6.1.4.1.186.1.19.2.3.12.5 | ipaddress | read-write |
Internet address subnet mask |
upsAgentDate | 1.3.6.1.4.1.186.1.19.2.3.12.6 | displaystring | read-write |
The date in agent, format is MM/DD/YYYY. |
upsAgentTime | 1.3.6.1.4.1.186.1.19.2.3.12.7 | displaystring | read-write |
The time in agent, format is HH:MM:SS. |
upsAgentGeneralRecordLogFrequency | 1.3.6.1.4.1.186.1.19.2.3.12.8 | integer | read-write |
The interval frequency of the general record log. The value is in seconds. |
upsAgentPollingRate | 1.3.6.1.4.1.186.1.19.2.3.12.9 | integer | read-write |
The frequency that proxy agent polls the connected UPS in RemotEye III protocols. |
upsAgentDHCPControl | 1.3.6.1.4.1.186.1.19.2.3.12.10 | integer | read-write |
Enable or disable DHCP/BootP capability Enumeration: 'enable': 1, 'disable': 2. |
upsAgentTelnetControl | 1.3.6.1.4.1.186.1.19.2.3.12.11 | integer | read-write |
Enable or disable telnet access Enumeration: 'enable': 1, 'disable': 2. |
upsAgentTFTPControl | 1.3.6.1.4.1.186.1.19.2.3.12.12 | integer | read-write |
Enable or disable network upgrade capability Enumeration: 'enable': 1, 'disable': 2. |
upsAgentResetToDefault | 1.3.6.1.4.1.186.1.19.2.3.12.13 | integer | read-write |
Reset all parameters of REMOTEYE III to default value Enumeration: 'enable': 1, 'disable': 2. |
upsAgentRestart | 1.3.6.1.4.1.186.1.19.2.3.12.14 | integer | read-write |
Restart REMOTEYE III Enumeration: 'enable': 1, 'disable': 2. |
upsAgentSystemName | 1.3.6.1.4.1.186.1.19.2.3.12.15 | displaystring | read-write |
The Agent System name |
upsAgentSystemContact | 1.3.6.1.4.1.186.1.19.2.3.12.16 | displaystring | read-write |
Contact Information |
upsAgentSystemLocation | 1.3.6.1.4.1.186.1.19.2.3.12.17 | displaystring | read-write |
Agent Location |
upsAgentDefaultLanguage | 1.3.6.1.4.1.186.1.19.2.3.12.18 | integer | read-write |
Current Default Language Enumeration: 'auto': 1, 'english': 2. |
upsAgentClearGeneralHistory | 1.3.6.1.4.1.186.1.19.2.3.12.19 | integer | read-write |
Clear general history log data Enumeration: 'enable': 1, 'disable': 2. |
upsAgentClearTestHistory | 1.3.6.1.4.1.186.1.19.2.3.12.20 | integer | read-write |
Clear test history log data Enumeration: 'enable': 1, 'disable': 2. |
upsAgentClearBackupHistory | 1.3.6.1.4.1.186.1.19.2.3.12.21 | integer | read-write |
Clear Backup history log data Enumeration: 'enable': 1, 'disable': 2. |
upsAgentClearFaultHistory | 1.3.6.1.4.1.186.1.19.2.3.12.22 | integer | read-write |
Clear Fault history log data Enumeration: 'enable': 1, 'disable': 2. |
upsAgentClearOperationModeHistory | 1.3.6.1.4.1.186.1.19.2.3.12.23 | integer | read-write |
Clear operation mode history log data Enumeration: 'enable': 1, 'disable': 2. |
upsAgentClearWarningHistory | 1.3.6.1.4.1.186.1.19.2.3.12.24 | integer | read-write |
Clear warning history log data Enumeration: 'enable': 1, 'disable': 2. |
upsAgentClearSystemsettingsChangeHistory | 1.3.6.1.4.1.186.1.19.2.3.12.25 | integer | read-write |
Clear System settings change history log data Enumeration: 'enable': 1, 'disable': 2. |
upsAgentClearRMTIEventHistory | 1.3.6.1.4.1.186.1.19.2.3.12.26 | integer | read-write |
Clear RemotEye Event History log data Enumeration: 'enable': 1, 'disable': 2. |
upsConnectedClients | 1.3.6.1.4.1.186.1.19.2.3.13 | |||
upsConnectedClientsNum | 1.3.6.1.4.1.186.1.19.2.3.13.1 | nonnegativeinteger | read-only |
The count of clients which have registered for UPS Shutdown control. |
upsConnectedClientsTable | 1.3.6.1.4.1.186.1.19.2.3.13.2 | no-access |
The devices powered by UPS and registered to RemotEye III |
|
1.3.6.1.4.1.186.1.19.2.3.13.2.1 | no-access |
The devices protected by RemotEye III |
||
upsConnectedClientsIndex | 1.3.6.1.4.1.186.1.19.2.3.13.2.1.1 | positiveinteger | no-access |
The index of the device that is plugged into the UPS. |
upsConnectedClientsIPAddress | 1.3.6.1.4.1.186.1.19.2.3.13.2.1.2 | ipaddress | read-only |
The ip address of the device. |
upsConnectedClientsName | 1.3.6.1.4.1.186.1.19.2.3.13.2.1.3 | displaystring | read-only |
The name/description of the device plugged into the UPS. |
upsConnectedClientsTimeAtConnection | 1.3.6.1.4.1.186.1.19.2.3.13.2.1.4 | displaystring | read-only |
The time that the device registered to REMOTEYE III |
upsConnectedClientsShutdownDelay | 1.3.6.1.4.1.186.1.19.2.3.13.2.1.5 | displaystring | read-only |
The shutdown delay set on REMOTEYE III |
upsConnectedClientsConnectionTimeout | 1.3.6.1.4.1.186.1.19.2.3.13.2.1.6 | integer | read-only |
The device timeout counter. Unit: 10 seconds |
upsConnectedClientsShutdownTest | 1.3.6.1.4.1.186.1.19.2.3.13.2.1.7 | integer | read-only |
The client will shutdown test after receive shutdown request from REMOTEYE III. |
upsEmail | 1.3.6.1.4.1.186.1.19.2.3.14 | |||
upsEmailMailServer | 1.3.6.1.4.1.186.1.19.2.3.14.1 | displaystring | read-write |
The Email mail server for REMOTEYE III. |
upsEmailUserAccount | 1.3.6.1.4.1.186.1.19.2.3.14.2 | displaystring | read-write |
The Email mail server login name. |
upsEmailUserPassword | 1.3.6.1.4.1.186.1.19.2.3.14.3 | displaystring | read-write |
The Email mail server password. |
upsEmailDomainName | 1.3.6.1.4.1.186.1.19.2.3.14.4 | displaystring | read-write |
The Email mail server domain name |
upsEmailDNSServer | 1.3.6.1.4.1.186.1.19.2.3.14.5 | displaystring | read-write |
The Email DNS server name |
upsEmailStatusReportSendTime | 1.3.6.1.4.1.186.1.19.2.3.14.6 | displaystring | read-write |
The Email Status Report Send Time |
upsEmailClientsTable | 1.3.6.1.4.1.186.1.19.2.3.14.7 | no-access |
The email addresses that RemotEye III will send logs and status reports to. |
|
1.3.6.1.4.1.186.1.19.2.3.14.7.1 | no-access |
The email addresses that RemotEye III will send logs and status reports to. |
||
upsEmailClientsIndex | 1.3.6.1.4.1.186.1.19.2.3.14.7.1.1 | positiveinteger | read-only |
The index of the email clients. |
upsEmailClientsEmailAddress | 1.3.6.1.4.1.186.1.19.2.3.14.7.1.2 | displaystring | read-write |
The email address of the clients. |
upsEmailClientsDescription | 1.3.6.1.4.1.186.1.19.2.3.14.7.1.3 | displaystring | read-write |
The name/description of the clients. |
upsEmailClientsDailyStatusReportType | 1.3.6.1.4.1.186.1.19.2.3.14.7.1.4 | integer | read-write |
The type of daily information that clients would like to receive. Enumeration: 'fault-Records': 4, 'backup-Records': 3, 'system-Setting-Change-Record': 7, 'test-records': 2, 'operation-Mode-Records': 5, 'remotEye-III-Events-Log': 8, 'warning-Records': 6, 'general-test': 1. |
upsEmailClientsEventStatusReportType | 1.3.6.1.4.1.186.1.19.2.3.14.7.1.5 | integer | read-write |
The type of event information that clients would like to receive when event occurs. Enumeration: 'fault-Records': 4, 'backup-Records': 3, 'system-Setting-Change-Record': 7, 'test-records': 2, 'operation-Mode-Records': 5, 'remotEye-III-Events-Log': 8, 'warning-Records': 6, 'general-test': 1. |
upsEmailClientsInfoLevel | 1.3.6.1.4.1.186.1.19.2.3.14.7.1.6 | integer | read-write |
The type of information that clients would like to receive. Enumeration: 'fault': 1, 'warning': 2, 'informational': 3. |
upsSNMP | 1.3.6.1.4.1.186.1.19.2.3.15 | |||
upsSNMPVersion | 1.3.6.1.4.1.186.1.19.2.3.15.1 | integer | read-only |
The SNMP version Enumeration: 'disable': 1, 'snmpv1': 2, 'snmpv3': 3. |
upsSNMPTrapsReceiversTable | 1.3.6.1.4.1.186.1.19.2.3.15.2 | no-access |
A list of managers to send traps to. The number of entries is given by the value of upsSNMPNumTrapReceivers |
|
1.3.6.1.4.1.186.1.19.2.3.15.2.1 | no-access |
The managers to send traps to. |
||
upsSNMPTrapsReceiversIndex | 1.3.6.1.4.1.186.1.19.2.3.15.2.1.1 | positiveinteger | read-only |
The index to a trap receiver entry. |
upsSNMPTrapsReceiversIPAddress | 1.3.6.1.4.1.186.1.19.2.3.15.2.1.2 | ipaddress | read-write |
The IP address of the manager to send a trap to. |
upsSNMPTrapReceiversCommunityString | 1.3.6.1.4.1.186.1.19.2.3.15.2.1.3 | displaystring | read-write |
The community name to use in the trap when sent to the manager. |
upsSNMPTrapReceiversTrapType | 1.3.6.1.4.1.186.1.19.2.3.15.2.1.4 | integer | read-write |
The trap group that NMS desired. Enumeration: 'toshiba-trap': 2, 'none': 1, 'rfc1628-trap': 4, 'jema-trap': 3. |
upsSNMPTrapReceiversInfoReceivingSeverityLevel | 1.3.6.1.4.1.186.1.19.2.3.15.2.1.5 | integer | read-write |
The severity level of traps to be received by this manager. Enumeration: 'fault': 3, 'warning': 2, 'informational': 1. |
upsSNMPTrapReceiversDescription | 1.3.6.1.4.1.186.1.19.2.3.15.2.1.6 | displaystring | read-write |
Description of trap receivers |
upsSNMPCommunitiesTable | 1.3.6.1.4.1.186.1.19.2.3.15.3 | no-access |
A list of managers which can access REMOTEYE III with private community string. |
|
1.3.6.1.4.1.186.1.19.2.3.15.3.1 | no-access |
The managers. |
||
upsSNMPCommunitiesIndex | 1.3.6.1.4.1.186.1.19.2.3.15.3.1.1 | positiveinteger | read-only |
The index to a access control entry. |
upsSNMPCommunitiesIPAddress | 1.3.6.1.4.1.186.1.19.2.3.15.3.1.2 | ipaddress | read-write |
The IP address of the manager to access REMOTEYE III |
upsSNMPCommunitiesAccessString | 1.3.6.1.4.1.186.1.19.2.3.15.3.1.3 | displaystring | read-write |
The community name to use in the manager when access REMOTEYE III |
upsSNMPCommunitiesAccessMode | 1.3.6.1.4.1.186.1.19.2.3.15.3.1.4 | integer | read-write |
Access type, only read/Write access type can change parameter of REMOTEYE III Enumeration: 'read-write': 2, 'readOnly': 1, 'notAccess': 3. |
upsEMD | 1.3.6.1.4.1.186.1.19.2.3.16 | |||
upsEMDType | 1.3.6.1.4.1.186.1.19.2.3.16.1 | displaystring | read-only |
The name assign to specific EMD. |
upsEMDTemperature | 1.3.6.1.4.1.186.1.19.2.3.16.2 | integer | read-only |
The EMD temperature. |
upsEMDTemperatureLowWarningSetPoint | 1.3.6.1.4.1.186.1.19.2.3.16.3 | integer | read-write |
The EMD temperature low warning set point. |
upsEMDTemperatureLowCriticalSetPoint | 1.3.6.1.4.1.186.1.19.2.3.16.4 | integer | read-write |
The EMD temperature low critical set point. |
upsEMDTemperatureHighWarningSetPoint | 1.3.6.1.4.1.186.1.19.2.3.16.5 | integer | read-write |
The EMD temperature high warning set point. |
upsEMDTemperatureHighCriticalSetPoint | 1.3.6.1.4.1.186.1.19.2.3.16.6 | integer | read-write |
The EMD temperature high critical set point. |
upsEMDTemperatureHysteresis | 1.3.6.1.4.1.186.1.19.2.3.16.7 | integer | read-write |
The EMD temperature hysteresis. |
upsEMDTemperatureCalibrationOffset | 1.3.6.1.4.1.186.1.19.2.3.16.8 | integer | read-write |
The EMD temperature calibration offset. |
upsEMDHumidity | 1.3.6.1.4.1.186.1.19.2.3.16.9 | integer | read-only |
The EMD Humidity. |
upsEMDHumidityLowWarningSetPoint | 1.3.6.1.4.1.186.1.19.2.3.16.10 | integer | read-write |
The EMD Humidity low warning set point. |
upsEMDHumidityLowCriticalSetPoint | 1.3.6.1.4.1.186.1.19.2.3.16.11 | integer | read-write |
The EMD Humidity low critical set point. |
upsEMDHumidityHighWarningSetPoint | 1.3.6.1.4.1.186.1.19.2.3.16.12 | integer | read-write |
The EMD Humidity high warning set point. |
upsEMDHumidityHighCriticalSetPoint | 1.3.6.1.4.1.186.1.19.2.3.16.13 | integer | read-write |
The EMD Humidity high critical set point. |
upsEMDHumidityHysteresis | 1.3.6.1.4.1.186.1.19.2.3.16.14 | integer | read-write |
The EMD Humidity hysteresis. |
upsEMDHumidityCalibrationOffset | 1.3.6.1.4.1.186.1.19.2.3.16.15 | integer | read-write |
The EMD Humidity calibration offset. |
upsEMDR1Status | 1.3.6.1.4.1.186.1.19.2.3.16.16 | integer | read-only |
The EMD dry contact 1 status. Enumeration: 'disabled': 2, 'unknown': 1, 'inactive': 4, 'active': 3. |
upsEMDAlarmR1Enable | 1.3.6.1.4.1.186.1.19.2.3.16.17 | integer | read-write |
The EMD contact R1 alarm enable setting. Enumeration: 'normalClose': 2, 'highActive': 4, 'disable': 1, 'lowActive': 5, 'normalOpen': 3. |
upsEMDAlarmR1Hysteresis | 1.3.6.1.4.1.186.1.19.2.3.16.18 | integer | read-write |
The EMD Contact R1 alarm hysteresis. |
upsEMDR2Status | 1.3.6.1.4.1.186.1.19.2.3.16.19 | integer | read-only |
The EMD dry contact 2 status. Enumeration: 'disabled': 2, 'unknown': 1, 'inactive': 4, 'active': 3. |
upsEMDAlarmR2Enable | 1.3.6.1.4.1.186.1.19.2.3.16.20 | integer | read-write |
The EMD contact R2 alarm enable setting. Enumeration: 'normalClose': 2, 'highActive': 4, 'disable': 1, 'lowActive': 5, 'normalOpen': 3. |
upsEMDAlarmR2Hysteresis | 1.3.6.1.4.1.186.1.19.2.3.16.21 | integer | read-write |
The EMD Contact R2 alarm hysteresis. |
upsTrap | 1.3.6.1.4.1.186.1.19.2.3.21 | |||
upsTrapFault | 1.3.6.1.4.1.186.1.19.2.30.1 |
Fault: One or more fault reported. |
||
upsTrapFaultClear | 1.3.6.1.4.1.186.1.19.2.30.2 |
Fault Clear: One or more fault reported. |
||
upsTrapOpenFuse | 1.3.6.1.4.1.186.1.19.2.30.3 |
Fault: An open fuse reported. |
||
upsTrapOpenFuseClear | 1.3.6.1.4.1.186.1.19.2.30.4 |
Fault Clear: An open fuse reported. |
||
upsTrapCurrentLimitFault | 1.3.6.1.4.1.186.1.19.2.30.5 |
Fault: A current limit fault reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapCurrentLimitFaultClear | 1.3.6.1.4.1.186.1.19.2.30.6 |
Fault Clear: A current limit fault reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapDCBusOverCurrent | 1.3.6.1.4.1.186.1.19.2.30.7 |
Fault: A DC bus overcurrent reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapDCBusOverCurrentClear | 1.3.6.1.4.1.186.1.19.2.30.8 |
Fault Clear: A DC bus overcurrent reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapDCBusOverVoltage | 1.3.6.1.4.1.186.1.19.2.30.9 |
Fault: A DC bus overvoltage reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapDCBusOverVoltageClear | 1.3.6.1.4.1.186.1.19.2.30.10 |
Fault Clear: A DC bus overvoltage reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapDCBusImbalance | 1.3.6.1.4.1.186.1.19.2.30.11 |
Fault: A DC bus imbalance reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapDCBusImbalanceClear | 1.3.6.1.4.1.186.1.19.2.30.12 |
Fault Clear: A DC bus imbalance reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapOutputUnderVoltage | 1.3.6.1.4.1.186.1.19.2.30.13 |
Fault: An output undervoltage reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapOutputUnderVoltageClear | 1.3.6.1.4.1.186.1.19.2.30.14 |
Fault Clear: An output undervoltage reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapOutputOverVoltage | 1.3.6.1.4.1.186.1.19.2.30.15 |
Fault: An output overvoltage reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapOutputOverVoltageClear | 1.3.6.1.4.1.186.1.19.2.30.16 |
Fault Clear: An output overvoltage reported. Contact your Toshiba authorized service center for examination. |
||
upsTrapHeatSinkOverheat | 1.3.6.1.4.1.186.1.19.2.30.17 |
Fault: A Heat sink or device overheat reported. |
||
upsTrapHeatSinkOverheatClear | 1.3.6.1.4.1.186.1.19.2.30.18 |
Fault Clear: A Heat sink or device overheat reported. |
||
upsTrapBypassOverload | 1.3.6.1.4.1.186.1.19.2.30.19 |
Fault: A bypass overload reported. |
||
upsTrapBypassOverloadClear | 1.3.6.1.4.1.186.1.19.2.30.20 |
Fault Clear: A bypass overload reported. |
||
upsTrapChargerOvervoltageFault | 1.3.6.1.4.1.186.1.19.2.30.21 |
Warning: Charger overvoltage reported. |
||
upsTrapChargerOvervoltageFaultClear | 1.3.6.1.4.1.186.1.19.2.30.22 |
Warning Clear: Charger overvoltage reported. |
||
upsTrapOutputOvercurrent | 1.3.6.1.4.1.186.1.19.2.30.23 |
Warning: An output overcurrent reported. |
||
upsTrapOutputOvercurrentClear | 1.3.6.1.4.1.186.1.19.2.30.24 |
Warning Clear: An output overcurrent reported. |
||
upsTrapDCUnderVoltageAtBoostUp | 1.3.6.1.4.1.186.1.19.2.30.25 |
Fault: A DC bus undervoltage during boost-up reported. |
||
upsTrapDCUnderVoltageAtBoostUpClear | 1.3.6.1.4.1.186.1.19.2.30.26 |
Fault Clear: A DC bus undervoltage during boost-up reported. |
||
upsTrapDCUnderVoltageAtCharge | 1.3.6.1.4.1.186.1.19.2.30.27 |
Fault: A DC bus undervoltage during charging reported. |
||
upsTrapDCUnderVoltageAtChargeClear | 1.3.6.1.4.1.186.1.19.2.30.28 |
Fault Clear: A DC bus undervoltage during charging reported. |
||
upsTrapBypassOverheat | 1.3.6.1.4.1.186.1.19.2.30.29 |
Fault: A Bypass overheat reported. |
||
upsTrapBypassOverheatClear | 1.3.6.1.4.1.186.1.19.2.30.30 |
Fault Clear: A Bypass overheat reported. |
||
upsTrapResettableInverterOverload | 1.3.6.1.4.1.186.1.19.2.30.31 |
Fault: An inverter overload reported. It is resettable. |
||
upsTrapResettableInverterOverloadClear | 1.3.6.1.4.1.186.1.19.2.30.32 |
Fault Clear: An inverter overload reported. It is resettable. |
||
upsTrapUnResettableInverterOverload | 1.3.6.1.4.1.186.1.19.2.30.33 |
Fault: An inverter overload reported. It is not resettable. |
||
upsTrapUnResettableInverterOverloadClear | 1.3.6.1.4.1.186.1.19.2.30.34 |
Fault Clear: An inverter overload reported. It is not resettable. |
||
upsTrapInputOverVoltage | 1.3.6.1.4.1.186.1.19.2.30.35 |
Warning: An input overvoltage reported. |
||
upsTrapInputOverVoltageClear | 1.3.6.1.4.1.186.1.19.2.30.36 |
Warning Clear: An input overvoltage reported. |
||
upsTrapInputUnderVoltage | 1.3.6.1.4.1.186.1.19.2.30.37 |
Warning: An input undervoltage reported. |
||
upsTrapInputUnderVoltageClear | 1.3.6.1.4.1.186.1.19.2.30.38 |
Warning Clear: An input undervoltage reported. |
||
upsTrapInputFrequencyError | 1.3.6.1.4.1.186.1.19.2.30.39 |
Warning: An input frequency error reported. |
||
upsTrapInputFrequencyErrorClear | 1.3.6.1.4.1.186.1.19.2.30.40 |
Warning Clear: An input frequency error reported. |
||
upsTrapBypassOverVoltage | 1.3.6.1.4.1.186.1.19.2.30.41 |
Warning: A bypass overvoltage reported. |
||
upsTrapBypassOverVoltageClear | 1.3.6.1.4.1.186.1.19.2.30.42 |
Warning Clear: A bypass overvoltage reported. |
||
upsTrapBypassUnderVoltage | 1.3.6.1.4.1.186.1.19.2.30.43 |
Warning: A bypass undervoltage reported. |
||
upsTrapBypassUnderVoltageClear | 1.3.6.1.4.1.186.1.19.2.30.44 |
Warning Clear: A bypass undervoltage reported. |
||
upsTrapBypassFrequencyError | 1.3.6.1.4.1.186.1.19.2.30.45 |
Warning: A bypass frequency error reported. |
||
upsTrapBypassFrequencyErrorClear | 1.3.6.1.4.1.186.1.19.2.30.46 |
Warning Clear: A bypass frequency error reported. |
||
upsTrapDCUnderVoltageAtTest | 1.3.6.1.4.1.186.1.19.2.30.47 |
Warning: A DC bus undervoltage during battery test reported. |
||
upsTrapDCUnderVoltageAtTestClear | 1.3.6.1.4.1.186.1.19.2.30.48 |
Warning Clear: A DC bus undervoltage during battery test reported. |
||
upsTrapBatteryLow | 1.3.6.1.4.1.186.1.19.2.30.49 |
Warning: A low battery level reported. |
||
upsTrapBatteryLowClear | 1.3.6.1.4.1.186.1.19.2.30.50 |
Warning Clear: A low battery level reported. |
||
upsTrapBatteryAtShutdownlevel | 1.3.6.1.4.1.186.1.19.2.30.51 |
Warning: A shutdown battery level reported. |
||
upsTrapBatteryAtShutdownlevelClear | 1.3.6.1.4.1.186.1.19.2.30.52 |
Warning Clear: A shutdown battery level reported. |
||
upsTrapReplaceBattery | 1.3.6.1.4.1.186.1.19.2.30.53 |
Warning: A replacement of batteries reported. |
||
upsTrapReplaceBatteryClear | 1.3.6.1.4.1.186.1.19.2.30.54 |
Warning Clear: A replacement of batteries reported. |
||
upsTrapChargerOverVoltageWarning | 1.3.6.1.4.1.186.1.19.2.30.55 |
Warning: A charger overvoltage reported. |
||
upsTrapChargerOverVoltageWarningClear | 1.3.6.1.4.1.186.1.19.2.30.56 |
Warning Clear: A charger overvoltage reported. |
||
upsTrapBatteryTestFailed | 1.3.6.1.4.1.186.1.19.2.30.57 |
Warning: A battery test failed event reported. |
||
upsTrapBatteryTestFailedClear | 1.3.6.1.4.1.186.1.19.2.30.58 |
Warning Clear: A battery test failed event reported. |
||
upsTrapBatteryDepleted | 1.3.6.1.4.1.186.1.19.2.30.59 |
Warning: A battery depleted event reported. |
||
upsTrapBatteryDepletedClear | 1.3.6.1.4.1.186.1.19.2.30.60 |
Warning Clear: A battery depleted event reported. |
||
upsTrapBatteryOverheat | 1.3.6.1.4.1.186.1.19.2.30.61 |
Warning: A battery overheat reported. |
||
upsTrapBatteryOverheatClear | 1.3.6.1.4.1.186.1.19.2.30.62 |
Warning Clear: A battery overheat reported. |
||
upsTrapSystemOverheat | 1.3.6.1.4.1.186.1.19.2.30.63 |
Warning: A system overheat reported. |
||
upsTrapSystemOverheatClear | 1.3.6.1.4.1.186.1.19.2.30.64 |
Warning Clear: A system overheat reported. |
||
upsTrapOutputOverloadWarning | 1.3.6.1.4.1.186.1.19.2.30.65 |
Warning: An output overload reported. |
||
upsTrapOutputOverloadWarningClear | 1.3.6.1.4.1.186.1.19.2.30.66 |
Warning Clear: An output overload reported. |
||
upsTrapCurrentLimitWarning | 1.3.6.1.4.1.186.1.19.2.30.67 |
Warning: A current limit reported. |
||
upsTrapCurrentLimitWarningClear | 1.3.6.1.4.1.186.1.19.2.30.68 |
Warning Clear: A current limit reported. |
||
upsTrapAsyncOperation | 1.3.6.1.4.1.186.1.19.2.30.69 |
Warning: An Asynchronous operation reported. |
||
upsTrapAsyncOperationClear | 1.3.6.1.4.1.186.1.19.2.30.70 |
Warning Clear: An Asynchronous operation reported. |
||
upsTrapServiceUPS | 1.3.6.1.4.1.186.1.19.2.30.71 |
Warning: UPS is in need of service. |
||
upsTrapServiceUPSClear | 1.3.6.1.4.1.186.1.19.2.30.72 |
Warning Clear: UPS is in need of service. |
||
upsTrapBatteryNearExpiration | 1.3.6.1.4.1.186.1.19.2.30.73 |
Warning: A near expiration of batteries reported. |
||
upsTrapBatteryNearExpirationClear | 1.3.6.1.4.1.186.1.19.2.30.74 |
Warning Clear: A near expiration of batteries reported. |
||
upsTrapBatteryExpired | 1.3.6.1.4.1.186.1.19.2.30.75 |
Warning: A expiration of batteries reported. |
||
upsTrapBatteryExpiredClear | 1.3.6.1.4.1.186.1.19.2.30.76 |
Warning Clear: A expiration of batteries reported. |
||
upsTrapDisplayCableError | 1.3.6.1.4.1.186.1.19.2.30.77 |
Warning: A display cable error reported. |
||
upsTrapDisplayCableErrorClear | 1.3.6.1.4.1.186.1.19.2.30.78 |
Warning Clear: A display cable error reported. |
||
upsTrapRemotEyeCommError | 1.3.6.1.4.1.186.1.19.2.30.79 |
Warning: A communication error between the main control and the RemotEye III reported. |
||
upsTrapRemotEyeCommErrorClear | 1.3.6.1.4.1.186.1.19.2.30.80 |
Warning Clear: A communication error between the main control and the RemotEye III reported. |
||
upsTrapRemotEyeUplinkCommError | 1.3.6.1.4.1.186.1.19.2.30.81 |
Warning: A communication error between the RemotEye III and the network reported. |
||
upsTrapRemotEyeUplinkCommErrorClear | 1.3.6.1.4.1.186.1.19.2.30.82 |
Warning Clear: A communication error between the RemotEye III and the network reported. |
||
upsTrapServicePortCommError | 1.3.6.1.4.1.186.1.19.2.30.83 |
Warning: A communication error between the main controller and the service port reported. |
||
upsTrapServicePortCommErrorClear | 1.3.6.1.4.1.186.1.19.2.30.84 |
Warning Clear: A communication error between the main controller and the service port reported. |
||
upsTrapDispCommError | 1.3.6.1.4.1.186.1.19.2.30.85 |
Warning: A communication error between the main controller and the display controller reported. |
||
upsTrapDispCommErrorClear | 1.3.6.1.4.1.186.1.19.2.30.86 |
Warning Clear: A communication error between the main controller and the display controller reported. |
||
upsTrapSystemTestFailed | 1.3.6.1.4.1.186.1.19.2.30.87 |
Warning: A system test failed event reported. |
||
upsTrapSystemTestFailedClear | 1.3.6.1.4.1.186.1.19.2.30.88 |
Warning Clear: A system test failed event reported. |
||
upsTrapBypassOn | 1.3.6.1.4.1.186.1.19.2.30.89 |
Warning: The UPS is in Stop (Bypass) mode. |
||
upsTrapBypassOnClear | 1.3.6.1.4.1.186.1.19.2.30.90 |
Warning Clear: The UPS is in Stop (Bypass) mode. |
||
upsTrapPowerFailure | 1.3.6.1.4.1.186.1.19.2.30.91 |
Info: A power failure reported. |
||
upsTrapPowerFailureClear | 1.3.6.1.4.1.186.1.19.2.30.92 |
Info Clear: A power failure reported. |
||
upsTrapShutdownPending | 1.3.6.1.4.1.186.1.19.2.30.93 |
Info: A output shutdown in progress reported. Output will turn off after delay. |
||
upsTrapShutdownPendingClear | 1.3.6.1.4.1.186.1.19.2.30.94 |
Info Clear: A output shutdown in progress reported. Output will turn off after delay. |
||
upsTrapOutputOffAsRequested | 1.3.6.1.4.1.186.1.19.2.30.95 |
Info: An output shutdown mode requested. |
||
upsTrapOutputOffAsRequestedClear | 1.3.6.1.4.1.186.1.19.2.30.96 |
Info Clear: An output shutdown mode requested. |
||
upsTrapOutputOff | 1.3.6.1.4.1.186.1.19.2.30.97 |
Info: The UPS system output is off. |
||
upsTrapOutputOffClear | 1.3.6.1.4.1.186.1.19.2.30.98 |
Info Clear: The UPS system output is off. |
||
upsTrapBatteryTestInProgress | 1.3.6.1.4.1.186.1.19.2.30.99 |
Info: A battery test in progress reported. |
||
upsTrapBatteryTestInProgressClear | 1.3.6.1.4.1.186.1.19.2.30.100 |
Info Clear: A battery test in progress reported. |
||
upsTrapBatteryOn | 1.3.6.1.4.1.186.1.19.2.30.101 |
Info: The UPS is on Battery mode; it is supplying output power from its batteries. |
||
upsTrapBatteryOnClear | 1.3.6.1.4.1.186.1.19.2.30.102 |
Info Clear: The UPS is on Battery mode; it is supplying output power from its batteries. |
||
upsTrapEMDSensor1AlarmTriggered | 1.3.6.1.4.1.186.1.19.2.30.103 |
Warning: EMD sensor 1 alarm is triggered. |
||
upsTrapEMDSensor1AlarmTriggeredClear | 1.3.6.1.4.1.186.1.19.2.30.104 |
Warning Clear: EMD sensor 1 alarm is triggered. |
||
upsTrapEMDSensor2AlarmTriggered | 1.3.6.1.4.1.186.1.19.2.30.105 |
Warning: EMD sensor 2 alarm is triggered. |
||
upsTrapEMDSensor2AlarmTriggeredClear | 1.3.6.1.4.1.186.1.19.2.30.106 |
Warning Clear: EMD sensor 2 alarm is triggered. |
||
upsTrapEMDHumidityAtLowCiriticalPoint | 1.3.6.1.4.1.186.1.19.2.30.107 |
Warning: EMD humidity is at low critical point. |
||
upsTrapEMDHumidityAtLowCiriticalPointClear | 1.3.6.1.4.1.186.1.19.2.30.108 |
Warning Clear: EMD humidity is at low critical point. |
||
upsTrapEMDHumidityAtHighCiriticalPoint | 1.3.6.1.4.1.186.1.19.2.30.109 |
Warning: EMD humidity is at high critical point. |
||
upsTrapEMDHumidityAtHighCiriticalPointClear | 1.3.6.1.4.1.186.1.19.2.30.110 |
Warning Clear: EMD humidity is at high critical point. |
||
upsTrapEMDHumidityAtLowWarningPoint | 1.3.6.1.4.1.186.1.19.2.30.111 |
Warning: EMD humidity is at low warning point. |
||
upsTrapEMDHumidityAtLowWarningPointClear | 1.3.6.1.4.1.186.1.19.2.30.112 |
Warning Clear: EMD humidity is at low warning point. |
||
upsTrapEMDHumidityAtHighWarningPoint | 1.3.6.1.4.1.186.1.19.2.30.113 |
Warning: EMD humidity is at high warning point. |
||
upsTrapEMDHumidityAtHighWarningPointClear | 1.3.6.1.4.1.186.1.19.2.30.114 |
Warning Clear: EMD humidity is at high warning point. |
||
upsTrapEMDTemperatureAtLowCiriticalPoint | 1.3.6.1.4.1.186.1.19.2.30.115 |
Warning: EMD Temperature is at low critical point. |
||
upsTrapEMDTemperatureAtLowCiriticalPointClear | 1.3.6.1.4.1.186.1.19.2.30.116 |
Warning Clear: EMD Temperature is at low critical point. |
||
upsTrapEMDTemperatureAtHighCiriticalPoint | 1.3.6.1.4.1.186.1.19.2.30.117 |
Warning: EMD Temperature is at high critical point. |
||
upsTrapEMDTemperatureAtHighCiriticalPointClear | 1.3.6.1.4.1.186.1.19.2.30.118 |
Warning Clear: EMD Temperature is at high critical point. |
||
upsTrapEMDTemperatureAtLowWarningPoint | 1.3.6.1.4.1.186.1.19.2.30.119 |
Warning: EMD Temperature is at low warning point. |
||
upsTrapEMDTemperatureAtLowWarningPointClear | 1.3.6.1.4.1.186.1.19.2.30.120 |
Warning Clear: EMD Temperature is at low warning point. |
||
upsTrapEMDTemperatureAtHighWarningPoint | 1.3.6.1.4.1.186.1.19.2.30.121 |
Warning: EMD Temperature is at high warning point. |
||
upsTrapEMDTemperatureAtHighWarningPointClear | 1.3.6.1.4.1.186.1.19.2.30.122 |
Warning Clear: EMD Temperature is at high warning point. |
||
upsTrapLogInError | 1.3.6.1.4.1.186.1.19.2.30.123 |
Info: Username/Password information is incorrect. |
||
upsTrapLogInErrorClear | 1.3.6.1.4.1.186.1.19.2.30.124 |