TN-THERMAL-PROTECTION-MIB: View SNMP OID List / Download MIB

VENDOR: TRANSITION ENGINEERING INC.


 Home MIB: TN-THERMAL-PROTECTION-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 tnThermalProtectionMIB 1.3.6.1.4.1.868.2.5.32
The mib module for thermal protection on ports
       tnThermalProtectionMIBNotifications 1.3.6.1.4.1.868.2.5.32.0
           tnThermalProtectionPortStatusChangedNotification 1.3.6.1.4.1.868.2.5.32.0.1
A notification generated by the local device sensing a change in the thermal protection port status. The change indicates the current temperature of a port turns to be higher, or lower, than its priority temperature.
       tnThermalProtectionMIBObjects 1.3.6.1.4.1.868.2.5.32.1
           tnThermalProtectionMgmt 1.3.6.1.4.1.868.2.5.32.1.1
               tnThermalProtectionPriorityTable 1.3.6.1.4.1.868.2.5.32.1.1.1 no-access
This table is for user to configure the temperature and its priority which the ports belong to.
                   tnThermalProtectionPriorityEntry 1.3.6.1.4.1.868.2.5.32.1.1.1.1 no-access
Each entry represents a temperature and its priority, 4 priorities are supported.
                       tnThermalProtectionPriorityIndex 1.3.6.1.4.1.868.2.5.32.1.1.1.1.1 integer read-only
The priority the port belongs to. 4 priorities are supported.
                       tnThermalProtectionPriorityTemperature 1.3.6.1.4.1.868.2.5.32.1.1.1.1.2 integer read-write
The temperature at which the ports with the corresponding priority will be turned off. Temperatures between 0 and 255 C are supported.
               tnThermalProtectionIfTable 1.3.6.1.4.1.868.2.5.32.1.1.2 no-access
This table lets user to configure the temperature priority of each port for thermal protection. When the temperature exceeds the configured thermal protection temperature, ports will be turned off in order to protect the chip from getting overheated or decrease the power consumption.
                   tnThermalProtectionIfEntry 1.3.6.1.4.1.868.2.5.32.1.1.2.1 no-access
Each entry lists the temperature priority of each port.
                       tnThermalProtectionIfPriority 1.3.6.1.4.1.868.2.5.32.1.1.2.1.1 integer read-write
The temperature priority of current port belongs to. Refer to tnThermalProtectionPriorityIndex
               tnThermalProtectionIfStatusTable 1.3.6.1.4.1.868.2.5.32.1.1.3 no-access
This table allows the user to inspect status information related to thermal protection.
                   tnThermalProtectionIfStatusEntry 1.3.6.1.4.1.868.2.5.32.1.1.3.1 no-access
Each entry lists the temperature priority of each port.
                       tnThermalProtectionIfStatusTemperature 1.3.6.1.4.1.868.2.5.32.1.1.3.1.1 integer read-only
Shows the current chip temperature in degrees Celsius.
                       tnThermalProtectionIfStatusCode 1.3.6.1.4.1.868.2.5.32.1.1.3.1.2 integer read-only
Shows if the port is thermally protected (link is down) or if the port is operating normally. Enumeration: 'linkdown': 1, 'normal': 0.