TN-SYNCE-MIB: View SNMP OID List / Download MIB

VENDOR: TRANSITION ENGINEERING INC.


 Home MIB: TN-SYNCE-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 tnSynceMIB 1.3.6.1.4.1.868.2.5.122
The mib provides functionalities for managing SyncE.
         tnSynce 1.3.6.1.4.1.868.2.5.122.1
             tnSyncETable 1.3.6.1.4.1.868.2.5.122.1.1 no-access
Table to manage SyncE for each device.
                 tnSyncEEntry 1.3.6.1.4.1.868.2.5.122.1.1.1 no-access
An entry containing SyncE for each device.
                     tnSyncEStateMode 1.3.6.1.4.1.868.2.5.122.1.1.1.1 integer read-write
Clock source selection mode manual: Selector is manually set to the chosen clock source selected: Selector is manually set to the pt. selected clock source (not possible in unlocked mode) nonrevertive: Selector is automatically selecting the best clock source - non revertively revertive: Selector is automatically selecting the best clock source - revertively holdover: Selector is forced in holdover freerun: Selector is forced in free run Enumeration: 'selected': 2, 'manual': 1, 'revertive': 4, 'nonrevertive': 3, 'freerun': 6, 'holdover': 5.
                     tnSyncEStateWTRTime 1.3.6.1.4.1.868.2.5.122.1.1.1.2 integer read-write
WTR (Wait-to-Restore) time in minutes(0-12 min) '0' is disable
                     tnSyncEStateSSMHoldOver 1.3.6.1.4.1.868.2.5.122.1.1.1.3 integer read-write
Synchronization Status Messaging Hold Over. Hold Over is switching over to Local Reference Clock if primary and secondary nodes fail prc = Primary Reference Clock eec2 Ethernet Equipment Clock 1.544 kpbs eec1 Ethernet Equipment Clock 2.048 kpbs Enumeration: 'eec2': 4, 'none': 0, 'ssua': 2, 'prc': 1, 'ssub': 3, 'inv': 7, 'eec1': 5, 'dn': 6.
                     tnSyncEStateSSMFreeRun 1.3.6.1.4.1.868.2.5.122.1.1.1.4 integer read-write
Synchronization Status Messaging Free Run Enumeration: 'eec2': 4, 'none': 0, 'ssua': 2, 'prc': 1, 'ssub': 3, 'inv': 7, 'eec1': 5, 'dn': 6.
                     tnSyncEAlarmStateLOL 1.3.6.1.4.1.868.2.5.122.1.1.1.5 truthvalue read-only
Alarm State Loss of Lock (LOL)
                     tnSyncEAlarmStateDHOLD 1.3.6.1.4.1.868.2.5.122.1.1.1.6 truthvalue read-only
Alarm State Digital Hold (DHOLD)
                     tnSyncESelState 1.3.6.1.4.1.868.2.5.122.1.1.1.7 integer read-only
Clock Selection State Note: prelock2, prelock and lossoflock are not available on all products Enumeration: 'prelock': 5, 'lockedto': 1, 'holdover': 2, 'freerun': 3, 'prelock2': 4, 'lossoflock': 6.
                     tnSyncEClkSrc 1.3.6.1.4.1.868.2.5.122.1.1.1.8 integer read-write
Clock Source
             tnSyncEClkSourceTable 1.3.6.1.4.1.868.2.5.122.1.2 no-access
Table of SyncE ClkSource
                 tnSyncEClkSourceEntry 1.3.6.1.4.1.868.2.5.122.1.2.1 no-access
An entry in the table,tnSyncEClkSourceTable
                     tnSyncEClkSourceIndex 1.3.6.1.4.1.868.2.5.122.1.2.1.1 integer read-only
Index of SyncE ClkSource table. 1-SYNCE_NOMINATED_MAX
                     tnSyncEConfPort 1.3.6.1.4.1.868.2.5.122.1.2.1.2 integer read-write
SyncE Configuration Port. 0-MAX_PORT. a port value of 0 means not nominated
                     tnSyncEConfSSMOverwrite 1.3.6.1.4.1.868.2.5.122.1.2.1.3 integer read-write
Clock source SSM overwrite Enumeration: 'eec2': 4, 'none': 0, 'ssua': 2, 'prc': 1, 'ssub': 3, 'eec1': 5, 'dn': 6.
                     tnSyncEConfHoldOff 1.3.6.1.4.1.868.2.5.122.1.2.1.4 integer read-write
The hold off timer value in 100 ms. Valid values are: 0 for disable. The range 3-18. The value 100 for test
                     tnSyncEConfANEG 1.3.6.1.4.1.868.2.5.122.1.2.1.5 integer read-write
Auto Negotiate : 1000BaseT ANEG mode slave: Activate prefer slave negotiation master: Activate prefer master negotiation forced: Activate forced slave negotiation. Enumeration: 'slave': 1, 'none': 0, 'master': 2, 'forced': 3.
                     tnSyncEPriority 1.3.6.1.4.1.868.2.5.122.1.2.1.6 integer read-write
Clock source priority setting. (SYNCE_PRIORITY_MAX = CLOCK_INPUT_MAX = 2 i.e. 0,1)
                     tnSyncEClear 1.3.6.1.4.1.868.2.5.122.1.2.1.7 truthvalue read-write
SyncE Clear.
                     tnSyncEAlarmStateLOCS 1.3.6.1.4.1.868.2.5.122.1.2.1.8 truthvalue read-only
SyncE Alarm State LOCS.
                     tnSyncEAlarmStateSSM 1.3.6.1.4.1.868.2.5.122.1.2.1.9 truthvalue read-only
SyncE Alarm State SSM.
                     tnSyncEAlarmStateWTR 1.3.6.1.4.1.868.2.5.122.1.2.1.10 truthvalue read-only
SyncE Alarm State WRT.
                     tnSyncENominated 1.3.6.1.4.1.868.2.5.122.1.2.1.11 truthvalue read-write
SyncE Nominated.
             tnSyncEPortTable 1.3.6.1.4.1.868.2.5.122.1.3 no-access
Table of SyncEPort.
                 tnSyncEPortEntry 1.3.6.1.4.1.868.2.5.122.1.3.1 no-access
An entry containing tnSynce.
                     tnSyncEStatePortIndex 1.3.6.1.4.1.868.2.5.122.1.3.1.1 integer read-only
SyncE Port index, 0-SYNCE_PORT_COUNT.
                     tnSyncEStateTxSSM 1.3.6.1.4.1.868.2.5.122.1.3.1.2 integer read-only
SyncE Transmit SSM State. Enumeration: 'eec2': 5, 'none': 0, 'ssua': 2, 'prc': 1, 'ssub': 3, 'inv': 7, 'eec1': 6, 'dn': 4, 'link': 9, 'fail': 8.
                     tnSyncEStateRxSSM 1.3.6.1.4.1.868.2.5.122.1.3.1.3 integer read-only
SyncE Receive SSM State. Enumeration: 'eec2': 5, 'none': 0, 'ssua': 2, 'prc': 1, 'ssub': 3, 'inv': 7, 'eec1': 6, 'dn': 4, 'link': 9, 'fail': 8.
                     tnSyncEStateSSMMode 1.3.6.1.4.1.868.2.5.122.1.3.1.4 integer read-only
SyncE SSM Mode. Enumeration: 'master': 1, 'slave': 2.
                     tnSyncESSMEnabled 1.3.6.1.4.1.868.2.5.122.1.3.1.5 integer read-write
SyncE SSM Enabled. Enumeration: 'enable': 1, 'disable': 2.
             tnSyncEExtTable 1.3.6.1.4.1.868.2.5.122.1.4 no-access
Table of SyncE External I/O
                 tnSyncEExtEntry 1.3.6.1.4.1.868.2.5.122.1.4.1 no-access
An entry in the table,tnSyncEExtTable
                     tnSyncEExtInState 1.3.6.1.4.1.868.2.5.122.1.4.1.1 integer read-write
External I/O in direction state. Enumeration: 'enable': 1, 'disable': 2.
                     tnSyncEExtOutState 1.3.6.1.4.1.868.2.5.122.1.4.1.2 integer read-write
External I/O out direction state. Enumeration: 'enable': 1, 'disable': 2.
                     tnSyncEExtInFreq 1.3.6.1.4.1.868.2.5.122.1.4.1.3 integer read-write
External I/O in direction frequency 8k-25Mhz table of values. Enumeration: 'f25Mhz': 7, 'f10000kHz': 5, 'f1544kHz': 3, 'f19440kHz': 6, 'f2048kHz': 4, 'f8kHz': 1, 'f64kHz': 2.
                     tnSyncEExtOutFreq 1.3.6.1.4.1.868.2.5.122.1.4.1.4 integer read-write
External I/O out direction frequency 8k-25Mhz table of values Enumeration: 'f25Mhz': 7, 'f10000kHz': 5, 'f1544kHz': 3, 'f19440kHz': 6, 'f2048kHz': 4, 'f8kHz': 1, 'f64kHz': 2.
                     tnSyncEExtImpedance 1.3.6.1.4.1.868.2.5.122.1.4.1.5 integer read-write
External I/O Impedance. Enumeration: 'imp50': 1, 'imp75': 2, 'hi-Z': 3.
                     tnSyncEActualInFreq 1.3.6.1.4.1.868.2.5.122.1.4.1.6 integer read-only
The actual input frequency in Hz.
                     tnSyncEActualOutFreq 1.3.6.1.4.1.868.2.5.122.1.4.1.7 integer read-only
The actual output frequency in Hz. If output state is disabled set to 0