Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 tnFraMIB 1.3.6.1.4.1.868.2.5.21
The mib module for managing all transition products with FRA(Fault relay alarm)
       tnFraObjects 1.3.6.1.4.1.868.2.5.21.1
           tnFraMgmt 1.3.6.1.4.1.868.2.5.21.1.1
               tnFraRelayAlarmState 1.3.6.1.4.1.868.2.5.21.1.1.1 integer read-write
Change the state of the relay when an alarm condition is active Normal (1): Relay is activated on alarm Negated(2): Relay is de-activated on alarm Enumeration: 'negated': 2, 'normal': 1.
               tnFraPowerSupplyTable 1.3.6.1.4.1.868.2.5.21.1.1.2 no-access
This table is used for configuring fault relay status of the powersupply modules
                   tnFraPowerSupplyEntry 1.3.6.1.4.1.868.2.5.21.1.1.2.1 no-access
This entry contains configuration element of tnFraPowerSupplyTable
                       tnFraPowerSupplyState 1.3.6.1.4.1.868.2.5.21.1.1.2.1.1 integer read-write
Trigger fault relay alarm while monitored power supply is not present Enabled(1) : Enable fault relay alarm. Disabled(2): Disable fault relay alarm. Enumeration: 'enable': 1, 'disable': 2.
               tnFraLinkTable 1.3.6.1.4.1.868.2.5.21.1.1.3 no-access
This table is used for configuring fault relay status of the each port
                   tnFraLinkEntry 1.3.6.1.4.1.868.2.5.21.1.1.3.1 no-access
The entry list the tnFraLinkState priority of each port
                       tnFraLinkState 1.3.6.1.4.1.868.2.5.21.1.1.3.1.1 integer read-write
Trigger fault relay alarm while monitored Port is down Enabled(1) : Enable fault relay alarm of the link. Disabled(2): Disable fault relay alarm of the link. Enumeration: 'enable': 1, 'disable': 2.