Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 timetraOesMIBModule 1.3.6.1.4.1.6527.1.1.3.98
This document is the SNMP MIB module to manage and provision the Optical Extension Shelf (OES) components of the Nokia SROS device. Copyright (c) 2013-2016 Nokia. All rights reserved. Reproduction of this document is authorized on the condition that the foregoing copyright notice is included. This SNMP MIB module (Specification) embodies Nokia's proprietary intellectual property. Nokia retains all title and ownership in the Specification, including any revisions. Nokia grants all interested parties a non-exclusive license to use and distribute an unmodified copy of this Specification in connection with management of Nokia products, and without fee, provided this copyright notice and license appear on all copies. This Specification is supplied 'as is', and Nokia makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
 tmnxOesConformance 1.3.6.1.4.1.6527.3.1.1.98
       tmnxOesCompliances 1.3.6.1.4.1.6527.3.1.1.98.1
           tmnxOesV14v0Compliance 1.3.6.1.4.1.6527.3.1.1.98.1.1
The compliance statement for management of OES on Nokia SROS series systems for release 14.0.
       tmnxOesGroups 1.3.6.1.4.1.6527.3.1.1.98.2
           tmnxOesV14v0Groups 1.3.6.1.4.1.6527.3.1.1.98.2.1
               tmnxOesGroupV14v0 1.3.6.1.4.1.6527.3.1.1.98.2.1.1
The group of objects supporting management of OES on Nokia SROS series systems in release 14.0.
               tmnxOesNotificationGroupV14v0 1.3.6.1.4.1.6527.3.1.1.98.2.1.2
The group of notifications supporting management of OES on Nokia SROS series systems in release 14.0.
               tmnxOesNotifyObjsGroupV14v0 1.3.6.1.4.1.6527.3.1.1.98.2.1.3
The group of notification objects supporting management of OES on Nokia SROS series systems in release 14.0.
 tmnxOesObjs 1.3.6.1.4.1.6527.3.1.2.98
       tmnxOesConfigObjs 1.3.6.1.4.1.6527.3.1.2.98.1
           tmnxOesCfCache 1.3.6.1.4.1.6527.3.1.2.98.1.1 integer read-write
The value of tmnxOesCfCache specifies the compact flash device that holds the cache space used by OES. This cache space holds OES artifacts (e.g. configuration database, software). Enumeration: 'cf2': 2, 'cf3': 3, 'cf1': 1.
           tmnxOesReboot 1.3.6.1.4.1.6527.3.1.2.98.1.2 integer read-write
The value of tmnxOesReboot specifies if the OES system will perform a reboot : notApplicable (0) - No action will be performed. coldReset (1) - Causes a cold reset of the OES system in which the hardware and software will be reinitialized on all EC(Equipment Controller) and line cards. It is a service affecting action. Enumeration: 'notApplicable': 0, 'coldReset': 1.
           tmnxOesSwUpgrade 1.3.6.1.4.1.6527.3.1.2.98.1.3 tmnxactiontype read-write
The value of tmnxOesSwUpgrade specifies an OES software upgrade where the location of the software is specified by tmnxSysSwReposPrimaryLocation, tmnxSysSwReposSecondaryLocation or tmnxSysSwReposTertiaryLocation. This is a service affecting upgrade.
           tmnxOesSoftwareRepository 1.3.6.1.4.1.6527.3.1.2.98.1.4 tnameditemorempty read-write
The value of tmnxOesSoftwareRepository specifies the software repository to be used by OES. An empty string indicates this object has not been configured.
           tmnxOesCtlCommsVRtrName 1.3.6.1.4.1.6527.3.1.2.98.1.5 tnameditemorempty read-write
The value of tmnxOesCtlCommsVRtrName specifies the name of the virtual router instance used in OES control communications. An empty string indicates this object has not been configured.
           tmnxOesCtlCommsAddressType 1.3.6.1.4.1.6527.3.1.2.98.1.6 inetaddresstype read-write
The value of tmnxOesCtlCommsAddressType specifies the address type of tmnxOesCtlCommsAddress.
           tmnxOesCtlCommsAddress 1.3.6.1.4.1.6527.3.1.2.98.1.7 inetaddress read-write
The value of tmnxOesCtlCommsAddress specifies the destination address of the master OES used in OES control communications.
           tmnxOesCtlCommsTimeout 1.3.6.1.4.1.6527.3.1.2.98.1.8 unsigned32 read-write
The value of tmnxOesCtlCommsTimeout specifies the maximum amount of time, in seconds, before declaring an individual request to the OES has timeout. Such a failed request is retried a number of times as specified by tmnxOesCtlCommsRetryLimit and the OES is declared unreachable if all retries also timeout.
           tmnxOesCtlCommsRetryLimit 1.3.6.1.4.1.6527.3.1.2.98.1.9 unsigned32 read-write
The value of tmnxOesCtlCommsRetryLimit specifies the maximum number of times the system will retry an attempt to communicate with the OES chassis before declaring the OES as unreachable. See also tmnxOesCtlCommsTimeout.
       tmnxOesStatObjs 1.3.6.1.4.1.6527.3.1.2.98.2
           tmnxOesRunningSwImage 1.3.6.1.4.1.6527.3.1.2.98.2.1 displaystring read-only
The value of tmnxOesRunningSwImage indicates the version of the software image running on PSS-1830.
           tmnxOesCtlCommsStatus 1.3.6.1.4.1.6527.3.1.2.98.2.2 integer read-only
The value of tmnxOesCtlCommsStatus indicates the status of the communication link with PSS-1830. Enumeration: 'down': 1, 'up': 0.
           tmnxOesStatus 1.3.6.1.4.1.6527.3.1.2.98.2.3 integer read-only
The value of tmnxOesStatus indicates the operational status of the OES: unprovisioned (0) - OES master chassis (oes-1) is not provisioned discovering (1) - OES discovery is in progress active (2) - OES is ready for operation inactive (3) - OES control communication is down provInProgress (4) - OES provisioning is in progress swUpgradeInProgress (5) - OES software upgrade is in progress Enumeration: 'inactive': 3, 'active': 2, 'provInProgress': 4, 'unprovisioned': 0, 'discovering': 1, 'swUpgradeInProgress': 5.
           tmnxOesNtpStatus 1.3.6.1.4.1.6527.3.1.2.98.2.4 integer read-only
The value of tmnxOesNtpStatus indicates the status of the Network Timing Protocol (NTP) for the OES. Enumeration: 'unknown': 1, 'freerun': 2, 'holdover': 3, 'sync': 4.
           tmnxOesUserPanelHwIndex 1.3.6.1.4.1.6527.3.1.2.98.2.5 tmnxhwindexorzero read-only
The value of tmnxOesUserPanelHwIndex indicates the hardware index of the OES user panel entry in the tmnxHwTable. This value will be 0 when the master OES chassis is not configured.
           tmnxOesUserPanelState 1.3.6.1.4.1.6527.3.1.2.98.2.6 tmnxdevicestate read-only
The value of tmnxOesUserPanelState indicates the OES USERPNL's operational state.
           tmnxOesCtlCommsDownReason 1.3.6.1.4.1.6527.3.1.2.98.2.7 integer read-only
The value of tmnxOesCtlCommsDownReason indicates the reason for the last time a loss of communication with the OES was detected. Values: unknownReason (0) - control communication failure for unknown reason adminReboot (1) - OES is rebooted via tmnxOesReboot noResponse (2) - no response was received for SNMP packet configFailed (3) - a SNMP SET, GET or GETNEXT during a configuration action did not complete correctly invalidSystem (4) - the OES sysObjectID does not contain the object identifier for a supported system invalidSoftware (5) - the OES software version is below the minimum supported version oesUnreachable (6) - OES is unreachable adminEcSwitchOver (7) - OES EC activity switch via tmnxOesChassisActivitySwitch ctlCommsUnprov (8) - missing or incomplete OES control communications provisioning clearActiveEcCard (9) - OES active EC clear via tmnxOesCardReboot Enumeration: 'ctlCommsUnprov': 8, 'adminEcSwitchOver': 7, 'unknownReason': 0, 'oesUnreachable': 6, 'clearActiveEcCard': 9, 'adminReboot': 1, 'configFailed': 3, 'invalidSoftware': 5, 'invalidSystem': 4, 'noResponse': 2.
           tmnxOesSwUpgradeLastStatus 1.3.6.1.4.1.6527.3.1.2.98.2.10 tmnxoesswmgmtstatus read-only
The value of tmnxOesSwUpgradeLastStatus indicates the status of the last OES software upgrade command tmnxOesSwUpgrade.
           tmnxOesSwUpgradeLastTime 1.3.6.1.4.1.6527.3.1.2.98.2.11 dateandtime read-only
The value of tmnxOesSwUpgradeLastTime indicates the time when the last OES software upgrade tmnxOesSwUpgrade was initiated.
           tmnxOesSwUpgradeCleanupLstStatus 1.3.6.1.4.1.6527.3.1.2.98.2.12 tmnxoesswmgmtstatus read-only
The value of tmnxOesSwUpgradeCleanupLstStatus indicates the status of the most recent OES software upgrade cleanup process initiated by the system due to upgrade failure on the remote node.
           tmnxOesSwUpgradeLastCompleteTime 1.3.6.1.4.1.6527.3.1.2.98.2.13 dateandtime read-only
The value of tmnxOesSwUpgradeLastCompleteTime indicates the time when the last OES software upgrade tmnxOesSwUpgrade was completed.
           tmnxOesExpectedSwImage 1.3.6.1.4.1.6527.3.1.2.98.2.14 displaystring read-only
The value of tmnxOesExpectedSwImage indicates the version of the software image expected on PSS-1830.
       tmnxOesNotifyObjs 1.3.6.1.4.1.6527.3.1.2.98.3
           tmnxOesEventReason 1.3.6.1.4.1.6527.3.1.2.98.3.1 tmnxoeseventreason no-access
The value of tmnxOesEventReason indicates the reason for which the notification is being triggered.
 tmnxOesMIBNotifyPrefix 1.3.6.1.4.1.6527.3.1.3.98
       tmnxOesNotifications 1.3.6.1.4.1.6527.3.1.3.98.0
           tmnxOesCtlCommsDown 1.3.6.1.4.1.6527.3.1.3.98.0.1
[CAUSE] The tmnxOesCtlCommsDown notification is generated when the active CPM can't reach the OES master chassis. [EFFECT] The OES can't be managed by the router. [RECOVERY] Ensure that all control communications ports between the router and the OES master chassis are correctly connected and test the cables.
           tmnxOesCtlCommsUp 1.3.6.1.4.1.6527.3.1.3.98.0.2
[CAUSE] The tmnxOesCtlCommsUp notification is generated when the active CPM can reach the OES master chassis. [EFFECT] The OES can be managed by the router. [RECOVERY] No recovery required.
           tmnxOesDbSyncFailure 1.3.6.1.4.1.6527.3.1.3.98.0.3
The active Equipment Controller is unable to synchronize its database with the inactive Equipment Controller. [CAUSE] The tmnxOesDbSyncFailure notification may be raised under the following conditions: 1) An incorrectly seated Equipment Controller; 2) The software versions on the active and inactive Equipment Controllers are not compatible; 3) A hardware problem with one or both controllers. [EFFECT] The OES does not have redundancy protection between the two Equipment Controller cards. [RECOVERY] Proceed as follows to clear the Database Synchronization Failed alarm: 1) Remove the Equipment Controller with the condition and examine the connector on the back of the card for damage, including bent or broken pins; 2) Examine the connector on the backplane for damage. If there is damage to the backplane of the shelf, contact your service representative; 3) Re-insert the Equipment Controller into its original slot and allow the card to initialize; 4) Repeat Step 2) through Step 4) for the second Equipment Controller; 5) Replace the Equipment Controller with the alarm condition with a new unit. If the condition is not cleared, replace the second Equipment Controller with a new unit. Follow the return and repair process to return the faulty card to an authorized repair center for replacement.
           tmnxOesDbSyncFailureClear 1.3.6.1.4.1.6527.3.1.3.98.0.4
[CAUSE] The tmnxOesDbSyncFailureClear notification is generated when the active Equipment Controller is able to synchronize its database with the inactive Equipment Controller. [EFFECT] The active and inactive Equipment Controller's databases are now synchronized. [RECOVERY] No recovery required.
           tmnxOesDbInvalid 1.3.6.1.4.1.6527.3.1.3.98.0.5
[CAUSE] The tmnxOesDbInvalid notification may be raised under the following conditions: 1) During initial installation, if the OES is not properly commissioned; 2) The serial number in the database does not match that of the OES either because the controller was replaced or the alarm card was replaced; 3) A downgrade of OES software has occurred; 4) Equipment Controller is removed/reseated during a system process, causing file corruption; 5) The database audit failed indicating some type of corruption of the database. [EFFECT] The OES is not in a normal operating mode. It does not have the correct configuration and the state of its cards is unpredictable. As a result, the OES will not boot normally and not all commands are allowed. [RECOVERY] A database corruption on the OES requires that the OES be re-commissioned. The correct database is held in the host system so it will be restored to the shelf once the existing database is cleared and the host re-establishes communication with the OES.
           tmnxOesDbInvalidClear 1.3.6.1.4.1.6527.3.1.3.98.0.6
[CAUSE] The tmnxOesDbInvalidClear notification is generated when the active Equipment Controller previously under tmnxOesDbInvalid condition now contains a valid database. [EFFECT] The OES active Equipment Controller's database is now valid. [RECOVERY] No recovery is required.
           tmnxOesDbUnsync 1.3.6.1.4.1.6527.3.1.3.98.0.7
[CAUSE] The tmnxOesDbUnsync notification is generated when the active and standby Equipment Controllers are not in sync. [EFFECT] The OES does not have redundancy protection between the two Equipment Controller cards. If a switchover were to occur, then the database of the newly active controller might not reflect the latest configuration. [RECOVERY] Proceed as follows to clear the Database Unsynchronization alarm: 1) Perform a warm reset of the standby controller; 2) If step 1 does not clear the alarm condition, then contact the next level of technical support for help.
           tmnxOesDbUnsyncClear 1.3.6.1.4.1.6527.3.1.3.98.0.8
[CAUSE] The tmnxOesDbUnsyncClear notification is generated when the previously out of sync database is now synchronized between the active and standby Equipment Controller cards. [EFFECT] The database is synchronized between the active and standby Equipment Controller cards. [RECOVERY] No recovery is required.
           tmnxOesSwUpgdFailed 1.3.6.1.4.1.6527.3.1.3.98.0.9
[CAUSE] The tmnxOesSwUpgdFailed notification is generated when a failure occurs in upgrading a component in the OES. This notification is applicable at the NE (Network Element) level and/or the card level. [EFFECT] The component is not upgraded. [RECOVERY] 1) Determine the reason the upgrade failed by checking the tmnxOesEventReason. First clear the condition indicated by the reason in the object tmnxOesEventReason. 2) Perform a soft reset on the card that failed to upgrade and try the upgrade procedure again. 3) Perform a hard reset on the card that failed to upgrade and try the upgrade procedure again. 4) Remove and re-insert the card that failed to upgrade and try the upgrade procedure again. 5) Replace the card that failed to upgrade and try the upgrade procedure again. 6) Inform the Nokia technical support team.
           tmnxOesNtpOutOfSync 1.3.6.1.4.1.6527.3.1.3.98.0.10
[CAUSE] The tmnxOesNtpOutOfSync notification is generated when NTP time on the OES is not synchronized to the host router. The host router must have NTP enabled and have recovered time from external time sources (NTP to PTP). If there is no NTP time source for the router, it will not serve time to the OES. In addition, once the NE is power cycled, it takes approximately 20-30 minutes to initialize. Thereafter, time synchronization will be completed, with a maximum delay time of 2-3 minutes. [EFFECT] Timestamp of each event occurring on the OES may not be exactly aligned with the host router. [RECOVERY] Ensure the host router has NTP configured and a reachable time source. Allow 40 minutes for the condition to clear.
           tmnxOesNtpSync 1.3.6.1.4.1.6527.3.1.3.98.0.11
[CAUSE] The tmnxOesNtpSync notification is generated when NTP on the OES is synchronized to the host router. The host router is serving acceptable time toward the OES and the OES has completed initial acquisition of time from the host. [EFFECT] None. [RECOVERY] No recovery is required.
           tmnxOesSwBelowMinRev 1.3.6.1.4.1.6527.3.1.3.98.0.12
[CAUSE] The tmnxOesSwBelowMinRev notification is generated when the version of the running OES software image is below the minimum expected version. [EFFECT] The OES may not be operating as expected. [RECOVERY] Upgrade the OES to a software image that is equal to or greater than the minimum expected version.
           tmnxOesFirmwareCondition 1.3.6.1.4.1.6527.3.1.3.98.0.13
[CAUSE] The tmnxOesFirmwareCondition notification is generated when the firmware on the card has a condition that needs to be notified to network administrator. The value of tmnxOesEventReason object specifies the reason. [EFFECT] Not all the features may be available. [RECOVERY] Perform a hard reset of the card. If the condition persists, then contact Nokia customer support.
           tmnxOesCfgFailNoMemory 1.3.6.1.4.1.6527.3.1.3.98.0.14
[CAUSE] The tmnxOesCfgFailNoMemory notification is generated when a request to obtain dynamic memory to download a configuration to the OES has failed. [EFFECT] The configuration is not active in the OES. [RECOVERY] This may be a temporary issue and the condition may clear on its own. If the event is raised periodically, then there is a permanent memory issue and the support organization should be informed.
           tmnxOesCfgBlocked 1.3.6.1.4.1.6527.3.1.3.98.0.15
[CAUSE] This event tmnxOesCfgBlocked notification is generated when a configuration being made in the OES is blocked. [EFFECT] The configuration is not active in the OES. [RECOVERY] One possible reason for this configuration failure is if there is a card present in the OES that is a supported card type but the router was not yet aware of its presence. This condition should clear as soon as the router becomes aware of the card. A second reason is when the supported card is present and is misaligned with the configuration (e.g. card present in slot 3 and 4, yet configuration is oes-1/2 where the width of card is two slots). This condition cannot be cleared automatically as the card has to be moved to the correct slot (or the configuration has to be removed for card oes-1/3 via cli command ). A third reason is when there is an unsupported card type in the OES that the router cannot manage. This condition cannot be cleared automatically and the OES will need to be recommissioned to clear the condition. Note: services on cards not impacted by the unknown card type are not affected.
           tmnxOesSwUpgdCleanupFailed 1.3.6.1.4.1.6527.3.1.3.98.0.16
[CAUSE] This event tmnxOesSwUpgdCleanupFailed notification is generated when the operation to clean-up a failed software upgrade fails. The reason for the failure is specified in the object tmnxOesEventReason. [EFFECT] The OES software revision cannot be determined and so the operational state of the respective OES or OES card is indeterminate. [RECOVERY] 1) Determine the reason for the upgrade failure from tmnxOesEventReason in the notification. First clear the condition indicated by the reason. 2) Re-try the upgrade procedure. 3) Contact the Nokia technical support team if the re-try does not fix the problem.