Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 wwanTrapsMIB 1.3.6.1.4.1.2007.1.4.211
This Module Information Base file is defined for managing received SNMP notifications generated by the WWAN event subsystem.
         wwanEventsGroup 1.3.6.1.4.1.2007.1.4.211.1
             wwanEventObjects1 1.3.6.1.4.1.2007.1.4.211.1.1
Event WWAN.1 Generic informational event.
                 wwan1_info_string 1.3.6.1.4.1.2007.1.4.211.1.1.1 displaystring no-access
Parameter 'info_string' in event WWAN.1
                 wwan1_ifcname 1.3.6.1.4.1.2007.1.4.211.1.1.2 displaystring no-access
Parameter 'ifcname' in event WWAN.1
             wwanEventObjects2 1.3.6.1.4.1.2007.1.4.211.1.2
Event WWAN.2 Generic error report.
                 wwan2_error_string 1.3.6.1.4.1.2007.1.4.211.1.2.1 displaystring no-access
Parameter 'error_string' in event WWAN.2
                 wwan2_ifcname 1.3.6.1.4.1.2007.1.4.211.1.2.2 displaystring no-access
Parameter 'ifcname' in event WWAN.2
             wwanEventObjects3 1.3.6.1.4.1.2007.1.4.211.1.3
Event WWAN.3 Registration state has changed.
                 wwan3_state 1.3.6.1.4.1.2007.1.4.211.1.3.1 displaystring no-access
Parameter 'state' in event WWAN.3
                 wwan3_ifcname 1.3.6.1.4.1.2007.1.4.211.1.3.2 displaystring no-access
Parameter 'ifcname' in event WWAN.3
             wwanEventObjects4 1.3.6.1.4.1.2007.1.4.211.1.4
Event WWAN.4 The wireless wan interface now uses a different Public Land Mobile Network, (Mobile Operator) identified by the number displayed.
                 wwan4_operator 1.3.6.1.4.1.2007.1.4.211.1.4.1 integer32 no-access
Parameter 'operator' in event WWAN.4
                 wwan4_ifcname 1.3.6.1.4.1.2007.1.4.211.1.4.2 displaystring no-access
Parameter 'ifcname' in event WWAN.4
             wwanEventObjects5 1.3.6.1.4.1.2007.1.4.211.1.5
Event WWAN.5 The wireless wan interface is connected to a different base station, identified by the Location Area Code (LAC) and the Cell Identifier code (CiD).
                 wwan5_location_area_code 1.3.6.1.4.1.2007.1.4.211.1.5.1 integer32 no-access
Parameter 'location_area_code' in event WWAN.5
                 wwan5_cell_id 1.3.6.1.4.1.2007.1.4.211.1.5.2 integer32 no-access
Parameter 'cell_id' in event WWAN.5
                 wwan5_ifcname 1.3.6.1.4.1.2007.1.4.211.1.5.3 displaystring no-access
Parameter 'ifcname' in event WWAN.5
             wwanEventObjects6 1.3.6.1.4.1.2007.1.4.211.1.6
Event WWAN.6 Notify a change of the used wireless wan technology, which implies different radio bands, coding methods and therefore different data rates.
                 wwan6_technology 1.3.6.1.4.1.2007.1.4.211.1.6.1 displaystring no-access
Parameter 'technology' in event WWAN.6
                 wwan6_ifcname 1.3.6.1.4.1.2007.1.4.211.1.6.2 displaystring no-access
Parameter 'ifcname' in event WWAN.6
             wwanEventObjects7 1.3.6.1.4.1.2007.1.4.211.1.7
Event WWAN.7 Received Signal Strength Indication (RSSI) changed to the level displayed. This event depends of user's configuration thresholds and appears only if the used technology is GSM or GPRS.
                 wwan7_rssi_level 1.3.6.1.4.1.2007.1.4.211.1.7.1 integer32 no-access
Parameter 'rssi_level' in event WWAN.7
                 wwan7_ifcname 1.3.6.1.4.1.2007.1.4.211.1.7.2 displaystring no-access
Parameter 'ifcname' in event WWAN.7
             wwanEventObjects8 1.3.6.1.4.1.2007.1.4.211.1.8
Event WWAN.8 Received Signal Code Power (RSCP) has changed to the level displayed or the EcNo ratio (received energy per chip divided by the power density in the band) has changed to the value displayed. This event depends of user's configuration thresholds and appears only if the used technology is UMTS, HSDPA or CDMA.
                 wwan8_rscp_level 1.3.6.1.4.1.2007.1.4.211.1.8.1 integer32 no-access
Parameter 'rscp_level' in event WWAN.8
                 wwan8_ecno_level 1.3.6.1.4.1.2007.1.4.211.1.8.2 integer32 no-access
Parameter 'ecno_level' in event WWAN.8
                 wwan8_ifcname 1.3.6.1.4.1.2007.1.4.211.1.8.3 displaystring no-access
Parameter 'ifcname' in event WWAN.8
             wwanEventObjects9 1.3.6.1.4.1.2007.1.4.211.1.9
Event WWAN.9 Active SIM is placed in the displayed socked.
                 wwan9_sim_socket 1.3.6.1.4.1.2007.1.4.211.1.9.1 displaystring no-access
Parameter 'sim_socket' in event WWAN.9
                 wwan9_ifcname 1.3.6.1.4.1.2007.1.4.211.1.9.2 displaystring no-access
Parameter 'ifcname' in event WWAN.9
             wwanEventObjects10 1.3.6.1.4.1.2007.1.4.211.1.10
Event WWAN.10 Interface call stated changed to the state displayed
                   wwan10_call_state_string 1.3.6.1.4.1.2007.1.4.211.1.10.1 displaystring no-access
Parameter 'call_state_string' in event WWAN.10
                   wwan10_call_state_num 1.3.6.1.4.1.2007.1.4.211.1.10.2 integer32 no-access
Parameter 'call_state_num' in event WWAN.10
                   wwan10_ifcname 1.3.6.1.4.1.2007.1.4.211.1.10.3 displaystring no-access
Parameter 'ifcname' in event WWAN.10
             wwanEventObjects11 1.3.6.1.4.1.2007.1.4.211.1.11
Event WWAN.11 A successful upgrade has been done to the displayed release
                   wwan11_frmwr_release 1.3.6.1.4.1.2007.1.4.211.1.11.1 displaystring no-access
Parameter 'frmwr_release' in event WWAN.11
                   wwan11_ifcname 1.3.6.1.4.1.2007.1.4.211.1.11.2 displaystring no-access
Parameter 'ifcname' in event WWAN.11
             wwanEventObjects12 1.3.6.1.4.1.2007.1.4.211.1.12
Event WWAN.12 Current SIM is the configured as main
                   wwan12_sim_socket 1.3.6.1.4.1.2007.1.4.211.1.12.1 displaystring no-access
Parameter 'sim_socket' in event WWAN.12
                   wwan12_ifcname 1.3.6.1.4.1.2007.1.4.211.1.12.2 displaystring no-access
Parameter 'ifcname' in event WWAN.12
             wwanEventObjects13 1.3.6.1.4.1.2007.1.4.211.1.13
Event WWAN.13 Current SIM is the configured as backup.
                   wwan13_sim_socket 1.3.6.1.4.1.2007.1.4.211.1.13.1 displaystring no-access
Parameter 'sim_socket' in event WWAN.13
                   wwan13_ifcname 1.3.6.1.4.1.2007.1.4.211.1.13.2 displaystring no-access
Parameter 'ifcname' in event WWAN.13
             wwanEventObjects14 1.3.6.1.4.1.2007.1.4.211.1.14
Event WWAN.14 A switching criteria is met and backup SIM is activated
                   wwan14_criteria 1.3.6.1.4.1.2007.1.4.211.1.14.1 displaystring no-access
Parameter 'criteria' in event WWAN.14
                   wwan14_sim_socket 1.3.6.1.4.1.2007.1.4.211.1.14.2 displaystring no-access
Parameter 'sim_socket' in event WWAN.14
                   wwan14_ifcname 1.3.6.1.4.1.2007.1.4.211.1.14.3 displaystring no-access
Parameter 'ifcname' in event WWAN.14
             wwanEventObjects15 1.3.6.1.4.1.2007.1.4.211.1.15
Event WWAN.15 A return criteria is met and main SIM is activated
                   wwan15_criteria 1.3.6.1.4.1.2007.1.4.211.1.15.1 displaystring no-access
Parameter 'criteria' in event WWAN.15
                   wwan15_sim_socket 1.3.6.1.4.1.2007.1.4.211.1.15.2 displaystring no-access
Parameter 'sim_socket' in event WWAN.15
                   wwan15_ifcname 1.3.6.1.4.1.2007.1.4.211.1.15.3 displaystring no-access
Parameter 'ifcname' in event WWAN.15
             wwanEventObjects16 1.3.6.1.4.1.2007.1.4.211.1.16
Event WWAN.16 A error is found and reported during SIM management
                   wwan16_error 1.3.6.1.4.1.2007.1.4.211.1.16.1 displaystring no-access
Parameter 'error' in event WWAN.16
                   wwan16_ifcname 1.3.6.1.4.1.2007.1.4.211.1.16.2 displaystring no-access
Parameter 'ifcname' in event WWAN.16
         wwanNotifications 1.3.6.1.4.1.2007.1.4.211.2
             wwanNotificationsPrefix 1.3.6.1.4.1.2007.1.4.211.2.0
                 wwanNotification1 1.3.6.1.4.1.2007.1.4.211.2.0.1
Notification of Event WWAN.1 Message: '$1 intf $2' Parameters list: $1: wwan1_info_string $2: wwan1_ifcname Generic informational event.
                 wwanNotification2 1.3.6.1.4.1.2007.1.4.211.2.0.2
Notification of Event WWAN.2 Message: '$1 intf $2' Parameters list: $1: wwan2_error_string $2: wwan2_ifcname Generic error report.
                 wwanNotification3 1.3.6.1.4.1.2007.1.4.211.2.0.3
Notification of Event WWAN.3 Message: 'CHANGED Registration state to $1, on interface $2' Parameters list: $1: wwan3_state $2: wwan3_ifcname Registration state has changed.
                 wwanNotification4 1.3.6.1.4.1.2007.1.4.211.2.0.4
Notification of Event WWAN.4 Message: 'CHANGED PLMN to $1, on interface $2' Parameters list: $1: wwan4_operator $2: wwan4_ifcname The wireless wan interface now uses a different Public Land Mobile Network, (Mobile Operator) identified by the number displayed.
                 wwanNotification5 1.3.6.1.4.1.2007.1.4.211.2.0.5
Notification of Event WWAN.5 Message: 'CHANGE Connected cell LAC $1 WWAN ID $2, on interface $3' Parameters list: $1: wwan5_location_area_code $2: wwan5_cell_id $3: wwan5_ifcname The wireless wan interface is connected to a different base station, identified by the Location Area Code (LAC) and the Cell Identifier code (CiD).
                 wwanNotification6 1.3.6.1.4.1.2007.1.4.211.2.0.6
Notification of Event WWAN.6 Message: 'CHANGED wireless wan technology to $1, on interface $2' Parameters list: $1: wwan6_technology $2: wwan6_ifcname Notify a change of the used wireless wan technology, which implies different radio bands, coding methods and therefore different data rates.
                 wwanNotification7 1.3.6.1.4.1.2007.1.4.211.2.0.7
Notification of Event WWAN.7 Message: 'CHANGED GSM/GPRS Coverage, RSSI $1 dBm, on interface $2' Parameters list: $1: wwan7_rssi_level $2: wwan7_ifcname Received Signal Strength Indication (RSSI) changed to the level displayed. This event depends of user's configuration thresholds and appears only if the used technology is GSM or GPRS.
                 wwanNotification8 1.3.6.1.4.1.2007.1.4.211.2.0.8
Notification of Event WWAN.8 Message: 'CHANGED 3GPP Coverage, RSCP to $1 dBm and EcNo to $2 dB, on interface $3' Parameters list: $1: wwan8_rscp_level $2: wwan8_ecno_level $3: wwan8_ifcname Received Signal Code Power (RSCP) has changed to the level displayed or the EcNo ratio (received energy per chip divided by the power density in the band) has changed to the value displayed. This event depends of user's configuration thresholds and appears only if the used technology is UMTS, HSDPA or CDMA.
                 wwanNotification9 1.3.6.1.4.1.2007.1.4.211.2.0.9
Notification of Event WWAN.9 Message: 'CHANGED Used SIM. Used SIM is located in the $1 socket, on interface $2' Parameters list: $1: wwan9_sim_socket $2: wwan9_ifcname Active SIM is placed in the displayed socked.
                 wwanNotification10 1.3.6.1.4.1.2007.1.4.211.2.0.10
Notification of Event WWAN.10 Message: 'CHANGED Call state to $1 ($2), on interface $3' Parameters list: $1: wwan10_call_state_string $2: wwan10_call_state_num $3: wwan10_ifcname Interface call stated changed to the state displayed
                 wwanNotification11 1.3.6.1.4.1.2007.1.4.211.2.0.11
Notification of Event WWAN.11 Message: 'CHANGED wireless wan module firmware to release $1, on interface $2' Parameters list: $1: wwan11_frmwr_release $2: wwan11_ifcname A successful upgrade has been done to the displayed release
                 wwanNotification12 1.3.6.1.4.1.2007.1.4.211.2.0.12
Notification of Event WWAN.12 Message: 'Main SIM is $1 and now is active, on interface $2' Parameters list: $1: wwan12_sim_socket $2: wwan12_ifcname Current SIM is the configured as main
                 wwanNotification13 1.3.6.1.4.1.2007.1.4.211.2.0.13
Notification of Event WWAN.13 Message: 'Backup SIM is $1, and now is active, on interface $2' Parameters list: $1: wwan13_sim_socket $2: wwan13_ifcname Current SIM is the configured as backup.
                 wwanNotification14 1.3.6.1.4.1.2007.1.4.211.2.0.14
Notification of Event WWAN.14 Message: 'Switching criteria $1 is met. Switching to backup SIM ($2), on interface $3' Parameters list: $1: wwan14_criteria $2: wwan14_sim_socket $3: wwan14_ifcname A switching criteria is met and backup SIM is activated
                 wwanNotification15 1.3.6.1.4.1.2007.1.4.211.2.0.15
Notification of Event WWAN.15 Message: 'Return criteria $1 is met. Switching to main SIM ($2), on interface $3' Parameters list: $1: wwan15_criteria $2: wwan15_sim_socket $3: wwan15_ifcname A return criteria is met and main SIM is activated
                 wwanNotification16 1.3.6.1.4.1.2007.1.4.211.2.0.16
Notification of Event WWAN.16 Message: 'SIM Management error $1, on interface $2' Parameters list: $1: wwan16_error $2: wwan16_ifcname A error is found and reported during SIM management