TELDAT-TRAP-I101-MIB: View SNMP OID List / Download MIB

VENDOR: TELDAT, S.A.


 Home MIB: TELDAT-TRAP-I101-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 i101TrapsMIB 1.3.6.1.4.1.2007.1.4.229
This Module Information Base file is defined for managing received SNMP notifications generated by the I101 event subsystem.
         i101EventsGroup 1.3.6.1.4.1.2007.1.4.229.1
             i101EventObjects1 1.3.6.1.4.1.2007.1.4.229.1.1
Event I101.1 Data has been received from Serial Terminal.
                 i1011_bytes_number 1.3.6.1.4.1.2007.1.4.229.1.1.1 integer32 no-access
Parameter 'bytes_number' in event I101.1
                 i1011_interface 1.3.6.1.4.1.2007.1.4.229.1.1.2 displaystring no-access
Parameter 'interface' in event I101.1
             i101EventObjects2 1.3.6.1.4.1.2007.1.4.229.1.2
Event I101.2 One OK Message has been received from Serial Terminal.
                 i1012_coment 1.3.6.1.4.1.2007.1.4.229.1.2.1 displaystring no-access
Parameter 'coment' in event I101.2
                 i1012_serrial_address 1.3.6.1.4.1.2007.1.4.229.1.2.2 integer32 no-access
Parameter 'serrial_address' in event I101.2
                 i1012_bytes_number 1.3.6.1.4.1.2007.1.4.229.1.2.3 integer32 no-access
Parameter 'bytes_number' in event I101.2
                 i1012_interface 1.3.6.1.4.1.2007.1.4.229.1.2.4 displaystring no-access
Parameter 'interface' in event I101.2
             i101EventObjects3 1.3.6.1.4.1.2007.1.4.229.1.3
Event I101.3 One Bad Message has been received from Serial Terminal.
                 i1013_cause 1.3.6.1.4.1.2007.1.4.229.1.3.1 displaystring no-access
Parameter 'cause' in event I101.3
                 i1013_interface 1.3.6.1.4.1.2007.1.4.229.1.3.2 displaystring no-access
Parameter 'interface' in event I101.3
             i101EventObjects4 1.3.6.1.4.1.2007.1.4.229.1.4
Event I101.4 A message with LRC/CRC error has been received from Serial Terminal.
                 i1014_interface 1.3.6.1.4.1.2007.1.4.229.1.4.1 displaystring no-access
Parameter 'interface' in event I101.4
             i101EventObjects5 1.3.6.1.4.1.2007.1.4.229.1.5
Event I101.5 A Message has been transmitted to Serial Terminal.
                 i1015_bytes 1.3.6.1.4.1.2007.1.4.229.1.5.1 integer32 no-access
Parameter 'bytes' in event I101.5
                 i1015_interface 1.3.6.1.4.1.2007.1.4.229.1.5.2 displaystring no-access
Parameter 'interface' in event I101.5
             i101EventObjects6 1.3.6.1.4.1.2007.1.4.229.1.6
Event I101.6 A change ON/OFF has been detected in Serial Control Signal Input.
                 i1016_message_type 1.3.6.1.4.1.2007.1.4.229.1.6.1 displaystring no-access
Parameter 'message_type' in event I101.6
                 i1016_interface 1.3.6.1.4.1.2007.1.4.229.1.6.2 displaystring no-access
Parameter 'interface' in event I101.6
             i101EventObjects7 1.3.6.1.4.1.2007.1.4.229.1.7
Event I101.7 A change ON/OFF has been make in Serial Control Signal Output.
                 i1017_message_type 1.3.6.1.4.1.2007.1.4.229.1.7.1 displaystring no-access
Parameter 'message_type' in event I101.7
                 i1017_interface 1.3.6.1.4.1.2007.1.4.229.1.7.2 displaystring no-access
Parameter 'interface' in event I101.7
             i101EventObjects8 1.3.6.1.4.1.2007.1.4.229.1.8
Event I101.8 Data error from Serial Terminal has been received.
                 i1018_message_type 1.3.6.1.4.1.2007.1.4.229.1.8.1 displaystring no-access
Parameter 'message_type' in event I101.8
                 i1018_interface 1.3.6.1.4.1.2007.1.4.229.1.8.2 displaystring no-access
Parameter 'interface' in event I101.8
             i101EventObjects9 1.3.6.1.4.1.2007.1.4.229.1.9
Event I101.9 Detailed Data send to serial interface.
                 i1019_interface 1.3.6.1.4.1.2007.1.4.229.1.9.1 displaystring no-access
Parameter 'interface' in event I101.9
                 i1019_serial_address 1.3.6.1.4.1.2007.1.4.229.1.9.2 integer32 no-access
Parameter 'serial_address' in event I101.9
                 i1019_lenght 1.3.6.1.4.1.2007.1.4.229.1.9.3 integer32 no-access
Parameter 'lenght' in event I101.9
                 i1019_hex_data 1.3.6.1.4.1.2007.1.4.229.1.9.4 displaystring no-access
Parameter 'hex_data' in event I101.9
             i101EventObjects10 1.3.6.1.4.1.2007.1.4.229.1.10
Event I101.10 Detailed Data received from serial interface.
                   i10110_interface 1.3.6.1.4.1.2007.1.4.229.1.10.1 displaystring no-access
Parameter 'interface' in event I101.10
                   i10110_serial_address 1.3.6.1.4.1.2007.1.4.229.1.10.2 integer32 no-access
Parameter 'serial_address' in event I101.10
                   i10110_lenght 1.3.6.1.4.1.2007.1.4.229.1.10.3 integer32 no-access
Parameter 'lenght' in event I101.10
                   i10110_hex_data 1.3.6.1.4.1.2007.1.4.229.1.10.4 displaystring no-access
Parameter 'hex_data' in event I101.10
             i101EventObjects11 1.3.6.1.4.1.2007.1.4.229.1.11
Event I101.11 A status change has occurred on RTU.
                   i10111_rtu 1.3.6.1.4.1.2007.1.4.229.1.11.1 displaystring no-access
Parameter 'rtu' in event I101.11
                   i10111_statsu 1.3.6.1.4.1.2007.1.4.229.1.11.2 displaystring no-access
Parameter 'statsu' in event I101.11
             i101EventObjects12 1.3.6.1.4.1.2007.1.4.229.1.12
Event I101.12 Tx data discarted due interface is in down state.
                   i10112_interface 1.3.6.1.4.1.2007.1.4.229.1.12.1 displaystring no-access
Parameter 'interface' in event I101.12
         i101Notifications 1.3.6.1.4.1.2007.1.4.229.2
             i101NotificationsPrefix 1.3.6.1.4.1.2007.1.4.229.2.0
                 i101Notification1 1.3.6.1.4.1.2007.1.4.229.2.0.1
Notification of Event I101.1 Message: 'Rx Data from Serial Terminal $1 bytes, interface $2' Parameters list: $1: i1011_bytes_number $2: i1011_interface Data has been received from Serial Terminal.
                 i101Notification2 1.3.6.1.4.1.2007.1.4.229.2.0.2
Notification of Event I101.2 Message: 'Rx Message $1 from Serial Terminal address $2, $3 bytes, interface $4' Parameters list: $1: i1012_coment $2: i1012_serrial_address $3: i1012_bytes_number $4: i1012_interface One OK Message has been received from Serial Terminal.
                 i101Notification3 1.3.6.1.4.1.2007.1.4.229.2.0.3
Notification of Event I101.3 Message: 'Rx Bad Message from Serial Terminal ($1), interface $2' Parameters list: $1: i1013_cause $2: i1013_interface One Bad Message has been received from Serial Terminal.
                 i101Notification4 1.3.6.1.4.1.2007.1.4.229.2.0.4
Notification of Event I101.4 Message: 'A block with LRC/CRC error has been received from Serial Terminal, interface $1' Parameters list: $1: i1014_interface A message with LRC/CRC error has been received from Serial Terminal.
                 i101Notification5 1.3.6.1.4.1.2007.1.4.229.2.0.5
Notification of Event I101.5 Message: 'Tx Message to Serial Terminal, $1 bytes interface $2' Parameters list: $1: i1015_bytes $2: i1015_interface A Message has been transmitted to Serial Terminal.
                 i101Notification6 1.3.6.1.4.1.2007.1.4.229.2.0.6
Notification of Event I101.6 Message: 'Serial Control Signal Imput CD change to $1, interface $2' Parameters list: $1: i1016_message_type $2: i1016_interface A change ON/OFF has been detected in Serial Control Signal Input.
                 i101Notification7 1.3.6.1.4.1.2007.1.4.229.2.0.7
Notification of Event I101.7 Message: 'Serial Control signal Output DTR change to $1, interface $2' Parameters list: $1: i1017_message_type $2: i1017_interface A change ON/OFF has been make in Serial Control Signal Output.
                 i101Notification8 1.3.6.1.4.1.2007.1.4.229.2.0.8
Notification of Event I101.8 Message: 'Data ERROR from Serial Terminal has been received type: $1. Interface $2' Parameters list: $1: i1018_message_type $2: i1018_interface Data error from Serial Terminal has been received.
                 i101Notification9 1.3.6.1.4.1.2007.1.4.229.2.0.9
Notification of Event I101.9 Message: 'Data transmitted to serial interface $1 (addr:$2,$3 bytes):$4' Parameters list: $1: i1019_interface $2: i1019_serial_address $3: i1019_lenght $4: i1019_hex_data Detailed Data send to serial interface.
                 i101Notification10 1.3.6.1.4.1.2007.1.4.229.2.0.10
Notification of Event I101.10 Message: 'Data received from serial interface $1 (addr:$2,$3 bytes):$4' Parameters list: $1: i10110_interface $2: i10110_serial_address $3: i10110_lenght $4: i10110_hex_data Detailed Data received from serial interface.
                 i101Notification11 1.3.6.1.4.1.2007.1.4.229.2.0.11
Notification of Event I101.11 Message: 'RTU $1 link status change to $2' Parameters list: $1: i10111_rtu $2: i10111_statsu A status change has occurred on RTU.
                 i101Notification12 1.3.6.1.4.1.2007.1.4.229.2.0.12
Notification of Event I101.12 Message: 'Data transmitted is discarted since interface $1 is down' Parameters list: $1: i10112_interface Tx data discarted due interface is in down state.