TELDAT-TRAP-G703-MIB: View SNMP OID List / Download MIB

VENDOR: TELDAT, S.A.


 Home MIB: TELDAT-TRAP-G703-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 g703TrapsMIB 1.3.6.1.4.1.2007.1.4.161
This Module Information Base file is defined for managing received SNMP notifications generated by the G703 event subsystem.
         g703EventsGroup 1.3.6.1.4.1.2007.1.4.161.1
             g703EventObjects1 1.3.6.1.4.1.2007.1.4.161.1.1
Event G703.1 Loss of Signal Alarm Set.
                 g7031_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.1.1 displaystring no-access
Parameter 'ifc-name' in event G703.1
             g703EventObjects2 1.3.6.1.4.1.2007.1.4.161.1.2
Event G703.2 Loss of Signal Alarm Clear.
                 g7032_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.2.1 displaystring no-access
Parameter 'ifc-name' in event G703.2
             g703EventObjects3 1.3.6.1.4.1.2007.1.4.161.1.3
Event G703.3 Out Of Frame Alarm Set.
                 g7033_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.3.1 displaystring no-access
Parameter 'ifc-name' in event G703.3
             g703EventObjects4 1.3.6.1.4.1.2007.1.4.161.1.4
Event G703.4 Out Of Frame Alarm Clear.
                 g7034_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.4.1 displaystring no-access
Parameter 'ifc-name' in event G703.4
             g703EventObjects5 1.3.6.1.4.1.2007.1.4.161.1.5
Event G703.5 Ramote Alarm Indication Set.
                 g7035_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.5.1 displaystring no-access
Parameter 'ifc-name' in event G703.5
             g703EventObjects6 1.3.6.1.4.1.2007.1.4.161.1.6
Event G703.6 Ramote Alarm Indication Clear.
                 g7036_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.6.1 displaystring no-access
Parameter 'ifc-name' in event G703.6
             g703EventObjects7 1.3.6.1.4.1.2007.1.4.161.1.7
Event G703.7 Alarm Indication Signal Set.
                 g7037_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.7.1 displaystring no-access
Parameter 'ifc-name' in event G703.7
             g703EventObjects8 1.3.6.1.4.1.2007.1.4.161.1.8
Event G703.8 Alarm Indication Signal Clear.
                 g7038_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.8.1 displaystring no-access
Parameter 'ifc-name' in event G703.8
             g703EventObjects9 1.3.6.1.4.1.2007.1.4.161.1.9
Event G703.9 Open Fail.
                 g7039_index 1.3.6.1.4.1.2007.1.4.161.1.9.1 integer32 no-access
Parameter 'index' in event G703.9
                 g7039_list 1.3.6.1.4.1.2007.1.4.161.1.9.2 integer32 no-access
Parameter 'list' in event G703.9
                 g7039_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.9.3 displaystring no-access
Parameter 'ifc-name' in event G703.9
             g703EventObjects10 1.3.6.1.4.1.2007.1.4.161.1.10
Event G703.10 Open Success.
                   g70310_index 1.3.6.1.4.1.2007.1.4.161.1.10.1 integer32 no-access
Parameter 'index' in event G703.10
                   g70310_list 1.3.6.1.4.1.2007.1.4.161.1.10.2 integer32 no-access
Parameter 'list' in event G703.10
                   g70310_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.10.3 displaystring no-access
Parameter 'ifc-name' in event G703.10
             g703EventObjects11 1.3.6.1.4.1.2007.1.4.161.1.11
Event G703.11 Close Fail.
                   g70311_index 1.3.6.1.4.1.2007.1.4.161.1.11.1 integer32 no-access
Parameter 'index' in event G703.11
                   g70311_list 1.3.6.1.4.1.2007.1.4.161.1.11.2 integer32 no-access
Parameter 'list' in event G703.11
                   g70311_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.11.3 displaystring no-access
Parameter 'ifc-name' in event G703.11
             g703EventObjects12 1.3.6.1.4.1.2007.1.4.161.1.12
Event G703.12 Close Success.
                   g70312_index 1.3.6.1.4.1.2007.1.4.161.1.12.1 integer32 no-access
Parameter 'index' in event G703.12
                   g70312_list 1.3.6.1.4.1.2007.1.4.161.1.12.2 integer32 no-access
Parameter 'list' in event G703.12
                   g70312_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.12.3 displaystring no-access
Parameter 'ifc-name' in event G703.12
             g703EventObjects13 1.3.6.1.4.1.2007.1.4.161.1.13
Event G703.13 A frame was transmitted.
                   g70313_index 1.3.6.1.4.1.2007.1.4.161.1.13.1 integer32 no-access
Parameter 'index' in event G703.13
                   g70313_value 1.3.6.1.4.1.2007.1.4.161.1.13.2 integer32 no-access
Parameter 'value' in event G703.13
                   g70313_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.13.3 displaystring no-access
Parameter 'ifc-name' in event G703.13
             g703EventObjects14 1.3.6.1.4.1.2007.1.4.161.1.14
Event G703.14 A frame was transmitted with error.
                   g70314_index 1.3.6.1.4.1.2007.1.4.161.1.14.1 integer32 no-access
Parameter 'index' in event G703.14
                   g70314_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.14.2 displaystring no-access
Parameter 'ifc-name' in event G703.14
             g703EventObjects15 1.3.6.1.4.1.2007.1.4.161.1.15
Event G703.15 A frame in the transmit path was dropped.
                   g70315_index 1.3.6.1.4.1.2007.1.4.161.1.15.1 integer32 no-access
Parameter 'index' in event G703.15
                   g70315_value 1.3.6.1.4.1.2007.1.4.161.1.15.2 integer32 no-access
Parameter 'value' in event G703.15
                   g70315_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.15.3 displaystring no-access
Parameter 'ifc-name' in event G703.15
             g703EventObjects16 1.3.6.1.4.1.2007.1.4.161.1.16
Event G703.16 A frame was received.
                   g70316_index 1.3.6.1.4.1.2007.1.4.161.1.16.1 integer32 no-access
Parameter 'index' in event G703.16
                   g70316_value 1.3.6.1.4.1.2007.1.4.161.1.16.2 integer32 no-access
Parameter 'value' in event G703.16
                   g70316_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.16.3 displaystring no-access
Parameter 'ifc-name' in event G703.16
             g703EventObjects17 1.3.6.1.4.1.2007.1.4.161.1.17
Event G703.17 A short frame was received.
                   g70317_index 1.3.6.1.4.1.2007.1.4.161.1.17.1 integer32 no-access
Parameter 'index' in event G703.17
                   g70317_value 1.3.6.1.4.1.2007.1.4.161.1.17.2 integer32 no-access
Parameter 'value' in event G703.17
                   g70317_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.17.3 displaystring no-access
Parameter 'ifc-name' in event G703.17
             g703EventObjects18 1.3.6.1.4.1.2007.1.4.161.1.18
Event G703.18 A frame was received with CRC error.
                   g70318_index 1.3.6.1.4.1.2007.1.4.161.1.18.1 integer32 no-access
Parameter 'index' in event G703.18
                   g70318_value 1.3.6.1.4.1.2007.1.4.161.1.18.2 integer32 no-access
Parameter 'value' in event G703.18
                   g70318_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.18.3 displaystring no-access
Parameter 'ifc-name' in event G703.18
             g703EventObjects19 1.3.6.1.4.1.2007.1.4.161.1.19
Event G703.19 A incomplete frame was received.
                   g70319_index 1.3.6.1.4.1.2007.1.4.161.1.19.1 integer32 no-access
Parameter 'index' in event G703.19
                   g70319_value 1.3.6.1.4.1.2007.1.4.161.1.19.2 integer32 no-access
Parameter 'value' in event G703.19
                   g70319_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.19.3 displaystring no-access
Parameter 'ifc-name' in event G703.19
             g703EventObjects20 1.3.6.1.4.1.2007.1.4.161.1.20
Event G703.20 A long frame was received. Check interface MTU.
                   g70320_index 1.3.6.1.4.1.2007.1.4.161.1.20.1 integer32 no-access
Parameter 'index' in event G703.20
                   g70320_value 1.3.6.1.4.1.2007.1.4.161.1.20.2 integer32 no-access
Parameter 'value' in event G703.20
                   g70320_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.20.3 displaystring no-access
Parameter 'ifc-name' in event G703.20
             g703EventObjects21 1.3.6.1.4.1.2007.1.4.161.1.21
Event G703.21 An aborted frame was received.
                   g70321_index 1.3.6.1.4.1.2007.1.4.161.1.21.1 integer32 no-access
Parameter 'index' in event G703.21
                   g70321_value 1.3.6.1.4.1.2007.1.4.161.1.21.2 integer32 no-access
Parameter 'value' in event G703.21
                   g70321_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.21.3 displaystring no-access
Parameter 'ifc-name' in event G703.21
             g703EventObjects22 1.3.6.1.4.1.2007.1.4.161.1.22
Event G703.22 Overflow on reception path.
                   g70322_index 1.3.6.1.4.1.2007.1.4.161.1.22.1 integer32 no-access
Parameter 'index' in event G703.22
                   g70322_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.22.2 displaystring no-access
Parameter 'ifc-name' in event G703.22
             g703EventObjects23 1.3.6.1.4.1.2007.1.4.161.1.23
Event G703.23 A frame received was dropped.
                   g70323_index 1.3.6.1.4.1.2007.1.4.161.1.23.1 integer32 no-access
Parameter 'index' in event G703.23
                   g70323_value 1.3.6.1.4.1.2007.1.4.161.1.23.2 integer32 no-access
Parameter 'value' in event G703.23
                   g70323_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.23.3 displaystring no-access
Parameter 'ifc-name' in event G703.23
             g703EventObjects24 1.3.6.1.4.1.2007.1.4.161.1.24
Event G703.24 A connection was created.
                   g70324_address 1.3.6.1.4.1.2007.1.4.161.1.24.1 integer32 no-access
Parameter 'address' in event G703.24
                   g70324_owner 1.3.6.1.4.1.2007.1.4.161.1.24.2 integer32 no-access
Parameter 'owner' in event G703.24
                   g70324_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.24.3 displaystring no-access
Parameter 'ifc-name' in event G703.24
             g703EventObjects25 1.3.6.1.4.1.2007.1.4.161.1.25
Event G703.25 A connection was released.
                   g70325_address 1.3.6.1.4.1.2007.1.4.161.1.25.1 integer32 no-access
Parameter 'address' in event G703.25
                   g70325_owner 1.3.6.1.4.1.2007.1.4.161.1.25.2 integer32 no-access
Parameter 'owner' in event G703.25
                   g70325_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.25.3 displaystring no-access
Parameter 'ifc-name' in event G703.25
             g703EventObjects26 1.3.6.1.4.1.2007.1.4.161.1.26
Event G703.26 Dynamic change on a group.
                   g70326_channel 1.3.6.1.4.1.2007.1.4.161.1.26.1 integer32 no-access
Parameter 'channel' in event G703.26
                   g70326_group 1.3.6.1.4.1.2007.1.4.161.1.26.2 integer32 no-access
Parameter 'group' in event G703.26
                   g70326_base_channel 1.3.6.1.4.1.2007.1.4.161.1.26.3 integer32 no-access
Parameter 'base-channel' in event G703.26
                   g70326_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.26.4 displaystring no-access
Parameter 'ifc-name' in event G703.26
             g703EventObjects27 1.3.6.1.4.1.2007.1.4.161.1.27
Event G703.27 Not enough buffers.
                   g70327_index 1.3.6.1.4.1.2007.1.4.161.1.27.1 integer32 no-access
Parameter 'index' in event G703.27
                   g70327_ifc_name 1.3.6.1.4.1.2007.1.4.161.1.27.2 displaystring no-access
Parameter 'ifc-name' in event G703.27
         g703Notifications 1.3.6.1.4.1.2007.1.4.161.2
             g703NotificationsPrefix 1.3.6.1.4.1.2007.1.4.161.2.0
                 g703Notification1 1.3.6.1.4.1.2007.1.4.161.2.0.1
Notification of Event G703.1 Message: 'Loss of Signal (Red Alarm) Set on interface $1' Parameters list: $1: g7031-ifc-name Loss of Signal Alarm Set.
                 g703Notification2 1.3.6.1.4.1.2007.1.4.161.2.0.2
Notification of Event G703.2 Message: 'Loss of Signal (Red Alarm) Clear on interface $1' Parameters list: $1: g7032-ifc-name Loss of Signal Alarm Clear.
                 g703Notification3 1.3.6.1.4.1.2007.1.4.161.2.0.3
Notification of Event G703.3 Message: 'Out Of Frame Alarm Set on interface $1' Parameters list: $1: g7033-ifc-name Out Of Frame Alarm Set.
                 g703Notification4 1.3.6.1.4.1.2007.1.4.161.2.0.4
Notification of Event G703.4 Message: 'Out Of Frame Alarm Clear on interface $1' Parameters list: $1: g7034-ifc-name Out Of Frame Alarm Clear.
                 g703Notification5 1.3.6.1.4.1.2007.1.4.161.2.0.5
Notification of Event G703.5 Message: 'Ramote Alarm Indication (Yellow Alarm) Set on interface $1' Parameters list: $1: g7035-ifc-name Ramote Alarm Indication Set.
                 g703Notification6 1.3.6.1.4.1.2007.1.4.161.2.0.6
Notification of Event G703.6 Message: 'Ramote Alarm Indication (Yellow Alarm) Clear on interface $1' Parameters list: $1: g7036-ifc-name Ramote Alarm Indication Clear.
                 g703Notification7 1.3.6.1.4.1.2007.1.4.161.2.0.7
Notification of Event G703.7 Message: 'Alarm Indication Signal (Blue Alarm) Set on interface $1' Parameters list: $1: g7037-ifc-name Alarm Indication Signal Set.
                 g703Notification8 1.3.6.1.4.1.2007.1.4.161.2.0.8
Notification of Event G703.8 Message: 'Alarm Indication Signal(Blue Alarm) Clear on interface $1' Parameters list: $1: g7038-ifc-name Alarm Indication Signal Clear.
                 g703Notification9 1.3.6.1.4.1.2007.1.4.161.2.0.9
Notification of Event G703.9 Message: 'Open Fail for channel $1 with time slot map $2 on interface $3' Parameters list: $1: g7039-index $2: g7039-list $3: g7039-ifc-name Open Fail.
                 g703Notification10 1.3.6.1.4.1.2007.1.4.161.2.0.10
Notification of Event G703.10 Message: 'Open Success for channel $1 with time slot map $2 on interface $3' Parameters list: $1: g70310-index $2: g70310-list $3: g70310-ifc-name Open Success.
                 g703Notification11 1.3.6.1.4.1.2007.1.4.161.2.0.11
Notification of Event G703.11 Message: 'Close Fail for channel $1 with time slot map $2 on interface $3' Parameters list: $1: g70311-index $2: g70311-list $3: g70311-ifc-name Close Fail.
                 g703Notification12 1.3.6.1.4.1.2007.1.4.161.2.0.12
Notification of Event G703.12 Message: 'Close Success for channel $1 with time slot map $2 on interface $3' Parameters list: $1: g70312-index $2: g70312-list $3: g70312-ifc-name Close Success.
                 g703Notification13 1.3.6.1.4.1.2007.1.4.161.2.0.13
Notification of Event G703.13 Message: 'Frame transmitted channel $1 length $2 on interface $3' Parameters list: $1: g70313-index $2: g70313-value $3: g70313-ifc-name A frame was transmitted.
                 g703Notification14 1.3.6.1.4.1.2007.1.4.161.2.0.14
Notification of Event G703.14 Message: 'Frame transmitted with error channel $1 on interface $2' Parameters list: $1: g70314-index $2: g70314-ifc-name A frame was transmitted with error.
                 g703Notification15 1.3.6.1.4.1.2007.1.4.161.2.0.15
Notification of Event G703.15 Message: 'Frame transmitted dropped channel $1 length $2 on interface $3' Parameters list: $1: g70315-index $2: g70315-value $3: g70315-ifc-name A frame in the transmit path was dropped.
                 g703Notification16 1.3.6.1.4.1.2007.1.4.161.2.0.16
Notification of Event G703.16 Message: 'Frame received channel $1 length $2 on interface $3' Parameters list: $1: g70316-index $2: g70316-value $3: g70316-ifc-name A frame was received.
                 g703Notification17 1.3.6.1.4.1.2007.1.4.161.2.0.17
Notification of Event G703.17 Message: 'Frame received short channel $1 length $2 on interface $3' Parameters list: $1: g70317-index $2: g70317-value $3: g70317-ifc-name A short frame was received.
                 g703Notification18 1.3.6.1.4.1.2007.1.4.161.2.0.18
Notification of Event G703.18 Message: 'Frame received with crc error channel $1 length $2 on interface $3' Parameters list: $1: g70318-index $2: g70318-value $3: g70318-ifc-name A frame was received with CRC error.
                 g703Notification19 1.3.6.1.4.1.2007.1.4.161.2.0.19
Notification of Event G703.19 Message: 'Incomplete frame received channel $1 length $2 on interface $3' Parameters list: $1: g70319-index $2: g70319-value $3: g70319-ifc-name A incomplete frame was received.
                 g703Notification20 1.3.6.1.4.1.2007.1.4.161.2.0.20
Notification of Event G703.20 Message: 'Long frame received channel $1 length $2 on interface $3' Parameters list: $1: g70320-index $2: g70320-value $3: g70320-ifc-name A long frame was received. Check interface MTU.
                 g703Notification21 1.3.6.1.4.1.2007.1.4.161.2.0.21
Notification of Event G703.21 Message: 'Aborted frame received channel $1 length $2 on interface $3' Parameters list: $1: g70321-index $2: g70321-value $3: g70321-ifc-name An aborted frame was received.
                 g703Notification22 1.3.6.1.4.1.2007.1.4.161.2.0.22
Notification of Event G703.22 Message: 'Reception overlow channel $1 on interface $2' Parameters list: $1: g70322-index $2: g70322-ifc-name Overflow on reception path.
                 g703Notification23 1.3.6.1.4.1.2007.1.4.161.2.0.23
Notification of Event G703.23 Message: 'Drop frame received channel $1 length $2 on interface $3' Parameters list: $1: g70323-index $2: g70323-value $3: g70323-ifc-name A frame received was dropped.
                 g703Notification24 1.3.6.1.4.1.2007.1.4.161.2.0.24
Notification of Event G703.24 Message: 'Create connection at $1 for $2 on interface $3' Parameters list: $1: g70324-address $2: g70324-owner $3: g70324-ifc-name A connection was created.
                 g703Notification25 1.3.6.1.4.1.2007.1.4.161.2.0.25
Notification of Event G703.25 Message: 'Release connection at $1 for $2 on interface $3' Parameters list: $1: g70325-address $2: g70325-owner $3: g70325-ifc-name A connection was released.
                 g703Notification26 1.3.6.1.4.1.2007.1.4.161.2.0.26
Notification of Event G703.26 Message: 'Dynamic remove channel $1 from group $2 base channel $3 on interface $4' Parameters list: $1: g70326-channel $2: g70326-group $3: g70326-base-channel $4: g70326-ifc-name Dynamic change on a group.
                 g703Notification27 1.3.6.1.4.1.2007.1.4.161.2.0.27
Notification of Event G703.27 Message: 'Reception error not enough buffer for channel $1 on interface $2' Parameters list: $1: g70327-index $2: g70327-ifc-name Not enough buffers.