TELDAT-TRAP-FR-MIB: View SNMP OID List / Download MIB
VENDOR: TELDAT, S.A.
Home | MIB: TELDAT-TRAP-FR-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
frTrapsMIB | 1.3.6.1.4.1.2007.1.4.92 |
This Module Information Base file is defined for managing received SNMP notifications generated by the FR event subsystem. |
||
frEventsGroup | 1.3.6.1.4.1.2007.1.4.92.1 | |||
frEventObjects1 | 1.3.6.1.4.1.2007.1.4.92.1.1 |
Event FR.1 A frame had been received on the FR interface. |
||
fr1_circuit | 1.3.6.1.4.1.2007.1.4.92.1.1.1 | integer32 | no-access |
Parameter 'circuit' in event FR.1 |
fr1_protocol | 1.3.6.1.4.1.2007.1.4.92.1.1.2 | displaystring | no-access |
Parameter 'protocol' in event FR.1 |
fr1_size | 1.3.6.1.4.1.2007.1.4.92.1.1.3 | integer32 | no-access |
Parameter 'size' in event FR.1 |
fr1_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.1.4 | displaystring | no-access |
Parameter 'ifcname' in event FR.1 |
fr1_buffer | 1.3.6.1.4.1.2007.1.4.92.1.1.5 | displaystring | no-access |
Parameter 'buffer' in event FR.1 |
frEventObjects2 | 1.3.6.1.4.1.2007.1.4.92.1.2 |
Event FR.2 A frame had been transmitted on the FR interface. |
||
fr2_circuit | 1.3.6.1.4.1.2007.1.4.92.1.2.1 | integer32 | no-access |
Parameter 'circuit' in event FR.2 |
fr2_protocol | 1.3.6.1.4.1.2007.1.4.92.1.2.2 | displaystring | no-access |
Parameter 'protocol' in event FR.2 |
fr2_size | 1.3.6.1.4.1.2007.1.4.92.1.2.3 | integer32 | no-access |
Parameter 'size' in event FR.2 |
fr2_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.2.4 | displaystring | no-access |
Parameter 'ifcname' in event FR.2 |
fr2_buffer | 1.3.6.1.4.1.2007.1.4.92.1.2.5 | displaystring | no-access |
Parameter 'buffer' in event FR.2 |
frEventObjects3 | 1.3.6.1.4.1.2007.1.4.92.1.3 |
Event FR.3 A protocol frame had been discarded due to the PVC congested condition. |
||
fr3_circuit | 1.3.6.1.4.1.2007.1.4.92.1.3.1 | integer32 | no-access |
Parameter 'circuit' in event FR.3 |
fr3_protocol | 1.3.6.1.4.1.2007.1.4.92.1.3.2 | displaystring | no-access |
Parameter 'protocol' in event FR.3 |
fr3_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.3.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.3 |
frEventObjects4 | 1.3.6.1.4.1.2007.1.4.92.1.4 |
Event FR.4 The circuit is now experiencing congestion in the outbound direction. |
||
fr4_circuit | 1.3.6.1.4.1.2007.1.4.92.1.4.1 | integer32 | no-access |
Parameter 'circuit' in event FR.4 |
fr4_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.4.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.4 |
frEventObjects5 | 1.3.6.1.4.1.2007.1.4.92.1.5 |
Event FR.5 The circuit is now not experiencing congestion in the outbound direction. |
||
fr5_circuit | 1.3.6.1.4.1.2007.1.4.92.1.5.1 | integer32 | no-access |
Parameter 'circuit' in event FR.5 |
fr5_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.5.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.5 |
frEventObjects6 | 1.3.6.1.4.1.2007.1.4.92.1.6 |
Event FR.6 The circuit enters the active state. |
||
fr6_circuit | 1.3.6.1.4.1.2007.1.4.92.1.6.1 | integer32 | no-access |
Parameter 'circuit' in event FR.6 |
fr6_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.6.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.6 |
frEventObjects7 | 1.3.6.1.4.1.2007.1.4.92.1.7 |
Event FR.7 The LMI signalled present and active a circuit which had not been statically configured. |
||
fr7_circuit | 1.3.6.1.4.1.2007.1.4.92.1.7.1 | integer32 | no-access |
Parameter 'circuit' in event FR.7 |
fr7_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.7.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.7 |
frEventObjects8 | 1.3.6.1.4.1.2007.1.4.92.1.8 |
Event FR.8 The circuit enters the inactive state. |
||
fr8_circuit | 1.3.6.1.4.1.2007.1.4.92.1.8.1 | integer32 | no-access |
Parameter 'circuit' in event FR.8 |
fr8_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.8.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.8 |
frEventObjects9 | 1.3.6.1.4.1.2007.1.4.92.1.9 |
Event FR.9 The circuit is no longer available on the network. |
||
fr9_circuit | 1.3.6.1.4.1.2007.1.4.92.1.9.1 | integer32 | no-access |
Parameter 'circuit' in event FR.9 |
fr9_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.9.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.9 |
frEventObjects10 | 1.3.6.1.4.1.2007.1.4.92.1.10 |
Event FR.10 The circuit is now available on the network. |
||
fr10_circuit | 1.3.6.1.4.1.2007.1.4.92.1.10.1 | integer32 | no-access |
Parameter 'circuit' in event FR.10 |
fr10_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.10.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.10 |
frEventObjects11 | 1.3.6.1.4.1.2007.1.4.92.1.11 |
Event FR.11 A LMI sequence number exchange has been requested. |
||
fr11_rcvseq | 1.3.6.1.4.1.2007.1.4.92.1.11.1 | integer32 | no-access |
Parameter 'rcvseq' in event FR.11 |
fr11_xmtseq | 1.3.6.1.4.1.2007.1.4.92.1.11.2 | integer32 | no-access |
Parameter 'xmtseq' in event FR.11 |
fr11_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.11.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.11 |
frEventObjects12 | 1.3.6.1.4.1.2007.1.4.92.1.12 |
Event FR.12 A LMI full Status Enquiry has been requested. |
||
fr12_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.12.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.12 |
frEventObjects13 | 1.3.6.1.4.1.2007.1.4.92.1.13 |
Event FR.13 A solicited LMI Status Enquiry response has been received. |
||
fr13_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.13.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.13 |
frEventObjects14 | 1.3.6.1.4.1.2007.1.4.92.1.14 |
Event FR.14 A LMI full Status Enquiry response has been received. |
||
fr14_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.14.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.14 |
frEventObjects15 | 1.3.6.1.4.1.2007.1.4.92.1.15 |
Event FR.15 A modem status change has occurred. The present state is described. |
||
fr15_dcd | 1.3.6.1.4.1.2007.1.4.92.1.15.1 | displaystring | no-access |
Parameter 'dcd' in event FR.15 |
fr15_cts | 1.3.6.1.4.1.2007.1.4.92.1.15.2 | displaystring | no-access |
Parameter 'cts' in event FR.15 |
fr15_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.15.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.15 |
frEventObjects16 | 1.3.6.1.4.1.2007.1.4.92.1.16 |
Event FR.16 A multicast frame had been transmitted on the FR interface. |
||
fr16_circuit | 1.3.6.1.4.1.2007.1.4.92.1.16.1 | integer32 | no-access |
Parameter 'circuit' in event FR.16 |
fr16_protocol | 1.3.6.1.4.1.2007.1.4.92.1.16.2 | displaystring | no-access |
Parameter 'protocol' in event FR.16 |
fr16_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.16.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.16 |
frEventObjects17 | 1.3.6.1.4.1.2007.1.4.92.1.17 |
Event FR.17 The circuit is remaining in the outbound congested state toward the network. |
||
fr17_circuit | 1.3.6.1.4.1.2007.1.4.92.1.17.1 | integer32 | no-access |
Parameter 'circuit' in event FR.17 |
fr17_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.17.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.17 |
frEventObjects18 | 1.3.6.1.4.1.2007.1.4.92.1.18 |
Event FR.18 A protocol frame had been discarded due to the PVC exceeding the CIR on the circuit. |
||
fr18_circuit | 1.3.6.1.4.1.2007.1.4.92.1.18.1 | integer32 | no-access |
Parameter 'circuit' in event FR.18 |
fr18_protocol | 1.3.6.1.4.1.2007.1.4.92.1.18.2 | displaystring | no-access |
Parameter 'protocol' in event FR.18 |
fr18_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.18.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.18 |
frEventObjects19 | 1.3.6.1.4.1.2007.1.4.92.1.19 |
Event FR.19 The LMI signalled present and active a circuit which had not been statically configured or allowed. |
||
fr19_circuit | 1.3.6.1.4.1.2007.1.4.92.1.19.1 | integer32 | no-access |
Parameter 'circuit' in event FR.19 |
fr19_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.19.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.19 |
frEventObjects20 | 1.3.6.1.4.1.2007.1.4.92.1.20 |
Event FR.20 The LMI signalled present and active a circuit which cannot join the interface, maximum circuits have been exceeded. |
||
fr20_circuit | 1.3.6.1.4.1.2007.1.4.92.1.20.1 | integer32 | no-access |
Parameter 'circuit' in event FR.20 |
fr20_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.20.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.20 |
frEventObjects21 | 1.3.6.1.4.1.2007.1.4.92.1.21 |
Event FR.21 The LMI signalled present and active a circuit which cannot join the interface, memory is unavailable. |
||
fr21_circuit | 1.3.6.1.4.1.2007.1.4.92.1.21.1 | integer32 | no-access |
Parameter 'circuit' in event FR.21 |
fr21_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.21.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.21 |
frEventObjects22 | 1.3.6.1.4.1.2007.1.4.92.1.22 |
Event FR.22 An unsupported management information element has been encountered. |
||
fr22_type | 1.3.6.1.4.1.2007.1.4.92.1.22.1 | integer32 | no-access |
Parameter 'type' in event FR.22 |
fr22_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.22.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.22 |
frEventObjects23 | 1.3.6.1.4.1.2007.1.4.92.1.23 |
Event FR.23 An unsupported management message has been encountered. |
||
fr23_type | 1.3.6.1.4.1.2007.1.4.92.1.23.1 | integer32 | no-access |
Parameter 'type' in event FR.23 |
fr23_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.23.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.23 |
frEventObjects24 | 1.3.6.1.4.1.2007.1.4.92.1.24 |
Event FR.24 The LMI signalled present and active a multicast circuit. |
||
fr24_circuit | 1.3.6.1.4.1.2007.1.4.92.1.24.1 | integer32 | no-access |
Parameter 'circuit' in event FR.24 |
fr24_group | 1.3.6.1.4.1.2007.1.4.92.1.24.2 | integer32 | no-access |
Parameter 'group' in event FR.24 |
fr24_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.24.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.24 |
frEventObjects25 | 1.3.6.1.4.1.2007.1.4.92.1.25 |
Event FR.25 The LMI signalled present and active a multicast circuit. |
||
fr25_circuit | 1.3.6.1.4.1.2007.1.4.92.1.25.1 | integer32 | no-access |
Parameter 'circuit' in event FR.25 |
fr25_group | 1.3.6.1.4.1.2007.1.4.92.1.25.2 | integer32 | no-access |
Parameter 'group' in event FR.25 |
fr25_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.25.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.25 |
frEventObjects26 | 1.3.6.1.4.1.2007.1.4.92.1.26 |
Event FR.26 An unsupported network layer protocol NLPID has been encountered. |
||
fr26_type | 1.3.6.1.4.1.2007.1.4.92.1.26.1 | integer32 | no-access |
Parameter 'type' in event FR.26 |
fr26_circuit | 1.3.6.1.4.1.2007.1.4.92.1.26.2 | integer32 | no-access |
Parameter 'circuit' in event FR.26 |
fr26_size | 1.3.6.1.4.1.2007.1.4.92.1.26.3 | integer32 | no-access |
Parameter 'size' in event FR.26 |
fr26_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.26.4 | displaystring | no-access |
Parameter 'ifcname' in event FR.26 |
frEventObjects27 | 1.3.6.1.4.1.2007.1.4.92.1.27 |
Event FR.27 An unsupported Ethernet type has been encountered. |
||
fr27_type | 1.3.6.1.4.1.2007.1.4.92.1.27.1 | integer32 | no-access |
Parameter 'type' in event FR.27 |
fr27_circuit | 1.3.6.1.4.1.2007.1.4.92.1.27.2 | integer32 | no-access |
Parameter 'circuit' in event FR.27 |
fr27_size | 1.3.6.1.4.1.2007.1.4.92.1.27.3 | integer32 | no-access |
Parameter 'size' in event FR.27 |
fr27_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.27.4 | displaystring | no-access |
Parameter 'ifcname' in event FR.27 |
frEventObjects28 | 1.3.6.1.4.1.2007.1.4.92.1.28 |
Event FR.28 The LMI signalled present and active a multicast circuit that is not supported on the interface. |
||
fr28_circuit | 1.3.6.1.4.1.2007.1.4.92.1.28.1 | integer32 | no-access |
Parameter 'circuit' in event FR.28 |
fr28_group | 1.3.6.1.4.1.2007.1.4.92.1.28.2 | integer32 | no-access |
Parameter 'group' in event FR.28 |
fr28_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.28.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.28 |
frEventObjects29 | 1.3.6.1.4.1.2007.1.4.92.1.29 |
Event FR.29 Data has been received on a circuit not configured or learned dynamically but not yet active on network. |
||
fr29_circuit | 1.3.6.1.4.1.2007.1.4.92.1.29.1 | integer32 | no-access |
Parameter 'circuit' in event FR.29 |
fr29_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.29.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.29 |
frEventObjects30 | 1.3.6.1.4.1.2007.1.4.92.1.30 |
Event FR.30 A LMI sequence number exchange has been received. |
||
fr30_rcvseq | 1.3.6.1.4.1.2007.1.4.92.1.30.1 | integer32 | no-access |
Parameter 'rcvseq' in event FR.30 |
fr30_xmtseq | 1.3.6.1.4.1.2007.1.4.92.1.30.2 | integer32 | no-access |
Parameter 'xmtseq' in event FR.30 |
fr30_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.30.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.30 |
frEventObjects31 | 1.3.6.1.4.1.2007.1.4.92.1.31 |
Event FR.31 An LMI unsolicited single status update message has been received. |
||
fr31_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.31.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.31 |
frEventObjects32 | 1.3.6.1.4.1.2007.1.4.92.1.32 |
Event FR.32 A frame containing less than the 2 octet minimum address length had been encountered. |
||
fr32_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.32.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.32 |
frEventObjects33 | 1.3.6.1.4.1.2007.1.4.92.1.33 |
Event FR.33 A frame containing greater than the 2 octet maximum address length supported had been encountered. Currently, only 2 octet addressing is supported. |
||
fr33_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.33.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.33 |
frEventObjects34 | 1.3.6.1.4.1.2007.1.4.92.1.34 |
Event FR.34 The LMI status message contained a reserved management channel address. |
||
fr34_circuit | 1.3.6.1.4.1.2007.1.4.92.1.34.1 | integer32 | no-access |
Parameter 'circuit' in event FR.34 |
fr34_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.34.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.34 |
frEventObjects35 | 1.3.6.1.4.1.2007.1.4.92.1.35 |
Event FR.35 An unsupported link layer control frame encountered. |
||
fr35_type | 1.3.6.1.4.1.2007.1.4.92.1.35.1 | integer32 | no-access |
Parameter 'type' in event FR.35 |
fr35_circuit | 1.3.6.1.4.1.2007.1.4.92.1.35.2 | integer32 | no-access |
Parameter 'circuit' in event FR.35 |
fr35_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.35.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.35 |
frEventObjects36 | 1.3.6.1.4.1.2007.1.4.92.1.36 |
Event FR.36 An unsupported network layer protocol descriptor has been encountered. |
||
fr36_type | 1.3.6.1.4.1.2007.1.4.92.1.36.1 | integer32 | no-access |
Parameter 'type' in event FR.36 |
fr36_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.36.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.36 |
frEventObjects37 | 1.3.6.1.4.1.2007.1.4.92.1.37 |
Event FR.37 An unsupported network layer call reference field has been encountered. |
||
fr37_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.37.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.37 |
frEventObjects38 | 1.3.6.1.4.1.2007.1.4.92.1.38 |
Event FR.38 The received ANSI management frame did not include required locking shift information element. |
||
fr38_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.38.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.38 |
frEventObjects39 | 1.3.6.1.4.1.2007.1.4.92.1.39 |
Event FR.39 The received management frame information element was incorrectly formated. |
||
fr39_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.39.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.39 |
frEventObjects40 | 1.3.6.1.4.1.2007.1.4.92.1.40 |
Event FR.40 An incorrect LMI receive sequence number has been received. |
||
fr40_rcvseq | 1.3.6.1.4.1.2007.1.4.92.1.40.1 | integer32 | no-access |
Parameter 'rcvseq' in event FR.40 |
fr40_xmtseq | 1.3.6.1.4.1.2007.1.4.92.1.40.2 | integer32 | no-access |
Parameter 'xmtseq' in event FR.40 |
fr40_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.40.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.40 |
frEventObjects41 | 1.3.6.1.4.1.2007.1.4.92.1.41 |
Event FR.41 The LMI failed to signal the mentioned circuit is last network status update message. Circuit assumed removed from network. |
||
fr41_circuit | 1.3.6.1.4.1.2007.1.4.92.1.41.1 | integer32 | no-access |
Parameter 'circuit' in event FR.41 |
fr41_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.41.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.41 |
frEventObjects42 | 1.3.6.1.4.1.2007.1.4.92.1.42 |
Event FR.42 The circuit is now experiencing congestion in the inbound direction. |
||
fr42_circuit | 1.3.6.1.4.1.2007.1.4.92.1.42.1 | integer32 | no-access |
Parameter 'circuit' in event FR.42 |
fr42_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.42.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.42 |
frEventObjects43 | 1.3.6.1.4.1.2007.1.4.92.1.43 |
Event FR.43 The address header on received management frame had BECN, FECN, DE or CR bits set. |
||
fr43_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.43.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.43 |
frEventObjects44 | 1.3.6.1.4.1.2007.1.4.92.1.44 |
Event FR.44 LMI Link Integrity Verification message was received from the network without the router polling for it. |
||
fr44_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.44.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.44 |
frEventObjects45 | 1.3.6.1.4.1.2007.1.4.92.1.45 |
Event FR.45 LMI Full Status message was received from the network without the router polling for it. |
||
fr45_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.45.1 | displaystring | no-access |
Parameter 'ifcname' in event FR.45 |
frEventObjects46 | 1.3.6.1.4.1.2007.1.4.92.1.46 |
Event FR.46 A frame was received of a bridge type defined in RFC 1490. However, since bridging has not been enabled on this circuit, frame is being discarded. |
||
fr46_circuit | 1.3.6.1.4.1.2007.1.4.92.1.46.1 | integer32 | no-access |
Parameter 'circuit' in event FR.46 |
fr46_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.46.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.46 |
frEventObjects47 | 1.3.6.1.4.1.2007.1.4.92.1.47 |
Event FR.47 A bridge frame is being discarded as a bridge port is not in forwarding state. |
||
fr47_circuit | 1.3.6.1.4.1.2007.1.4.92.1.47.1 | integer32 | no-access |
Parameter 'circuit' in event FR.47 |
fr47_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.47.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.47 |
frEventObjects48 | 1.3.6.1.4.1.2007.1.4.92.1.48 |
Event FR.48 A bridged frame has been received and is being discarded due to mismatch in the frame type versus the bridge port behavior. |
||
fr48_source_mac | 1.3.6.1.4.1.2007.1.4.92.1.48.1 | displaystring | no-access |
Parameter 'source-mac' in event FR.48 |
fr48_dest_mac | 1.3.6.1.4.1.2007.1.4.92.1.48.2 | displaystring | no-access |
Parameter 'dest-mac' in event FR.48 |
fr48_circuit | 1.3.6.1.4.1.2007.1.4.92.1.48.3 | integer32 | no-access |
Parameter 'circuit' in event FR.48 |
fr48_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.48.4 | displaystring | no-access |
Parameter 'ifcname' in event FR.48 |
frEventObjects49 | 1.3.6.1.4.1.2007.1.4.92.1.49 |
Event FR.49 An unsupported bridge frame type has been encountered. |
||
fr49_type | 1.3.6.1.4.1.2007.1.4.92.1.49.1 | integer32 | no-access |
Parameter 'type' in event FR.49 |
fr49_circuit | 1.3.6.1.4.1.2007.1.4.92.1.49.2 | integer32 | no-access |
Parameter 'circuit' in event FR.49 |
fr49_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.49.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.49 |
frEventObjects50 | 1.3.6.1.4.1.2007.1.4.92.1.50 |
Event FR.50 An unrecognized outgoing bridge frame type. Bridge has asked the Frame Relay interface to send out a frame whose type cannot be translated into encapsulation defined in RFC 1490. |
||
fr50_type | 1.3.6.1.4.1.2007.1.4.92.1.50.1 | integer32 | no-access |
Parameter 'type' in event FR.50 |
fr50_circuit | 1.3.6.1.4.1.2007.1.4.92.1.50.2 | integer32 | no-access |
Parameter 'circuit' in event FR.50 |
fr50_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.50.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.50 |
frEventObjects51 | 1.3.6.1.4.1.2007.1.4.92.1.51 |
Event FR.51 A protocol frame has been discarded because it could not be queued for transmission. |
||
fr51_circuit | 1.3.6.1.4.1.2007.1.4.92.1.51.1 | integer32 | no-access |
Parameter 'circuit' in event FR.51 |
fr51_protocol | 1.3.6.1.4.1.2007.1.4.92.1.51.2 | displaystring | no-access |
Parameter 'protocol' in event FR.51 |
fr51_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.51.3 | displaystring | no-access |
Parameter 'ifcname' in event FR.51 |
frEventObjects52 | 1.3.6.1.4.1.2007.1.4.92.1.52 |
Event FR.52 An LMI send sequence number of 0 has been received. |
||
fr52_sndseq | 1.3.6.1.4.1.2007.1.4.92.1.52.1 | integer32 | no-access |
Parameter 'sndseq' in event FR.52 |
fr52_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.52.2 | displaystring | no-access |
Parameter 'ifcname' in event FR.52 |
frEventObjects53 | 1.3.6.1.4.1.2007.1.4.92.1.53 |
Event FR.53 A FRF.12 fragment is processed and a event is reported. |
||
fr53_message | 1.3.6.1.4.1.2007.1.4.92.1.53.1 | displaystring | no-access |
Parameter 'message' in event FR.53 |
fr53_header | 1.3.6.1.4.1.2007.1.4.92.1.53.2 | integer32 | no-access |
Parameter 'header' in event FR.53 |
fr53_circuit | 1.3.6.1.4.1.2007.1.4.92.1.53.3 | integer32 | no-access |
Parameter 'circuit' in event FR.53 |
fr53_size | 1.3.6.1.4.1.2007.1.4.92.1.53.4 | integer32 | no-access |
Parameter 'size' in event FR.53 |
fr53_ifcname | 1.3.6.1.4.1.2007.1.4.92.1.53.5 | displaystring | no-access |
Parameter 'ifcname' in event FR.53 |
frNotifications | 1.3.6.1.4.1.2007.1.4.92.2 | |||
frNotificationsPrefix | 1.3.6.1.4.1.2007.1.4.92.2.0 | |||
frNotification1 | 1.3.6.1.4.1.2007.1.4.92.2.0.1 |
Notification of Event FR.1 Message: 'Frame received, PVC = $1 protocol type = $2 size $3 bytes, on interface $4HexadecimalData: $5' Parameters list: $1: fr1-circuit $2: fr1-protocol $3: fr1-size $4: fr1-ifcname $5: fr1-buffer A frame had been received on the FR interface. |
||
frNotification2 | 1.3.6.1.4.1.2007.1.4.92.2.0.2 |
Notification of Event FR.2 Message: 'Frame transmitted PVC = $1 protocol type = $2 size $3 bytes, on interface $4HexadecimalData: $5' Parameters list: $1: fr2-circuit $2: fr2-protocol $3: fr2-size $4: fr2-ifcname $5: fr2-buffer A frame had been transmitted on the FR interface. |
||
frNotification3 | 1.3.6.1.4.1.2007.1.4.92.2.0.3 |
Notification of Event FR.3 Message: 'Transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr3-circuit $2: fr3-protocol $3: fr3-ifcname A protocol frame had been discarded due to the PVC congested condition. |
||
frNotification4 | 1.3.6.1.4.1.2007.1.4.92.2.0.4 |
Notification of Event FR.4 Message: 'Circuit outbound congestion PVC = $1, on interface $2' Parameters list: $1: fr4-circuit $2: fr4-ifcname The circuit is now experiencing congestion in the outbound direction. |
||
frNotification5 | 1.3.6.1.4.1.2007.1.4.92.2.0.5 |
Notification of Event FR.5 Message: 'Circuit outbound uncongested PVC = $1, on interface $2' Parameters list: $1: fr5-circuit $2: fr5-ifcname The circuit is now not experiencing congestion in the outbound direction. |
||
frNotification6 | 1.3.6.1.4.1.2007.1.4.92.2.0.6 |
Notification of Event FR.6 Message: 'Circuit enters active state PVC = $1, on interface $2' Parameters list: $1: fr6-circuit $2: fr6-ifcname The circuit enters the active state. |
||
frNotification7 | 1.3.6.1.4.1.2007.1.4.92.2.0.7 |
Notification of Event FR.7 Message: 'An orphan circuit not statically configured has joined the network PVC = $1, on interface $2' Parameters list: $1: fr7-circuit $2: fr7-ifcname The LMI signalled present and active a circuit which had not been statically configured. |
||
frNotification8 | 1.3.6.1.4.1.2007.1.4.92.2.0.8 |
Notification of Event FR.8 Message: 'Circuit enters inactive state PVC = $1, on interface $2' Parameters list: $1: fr8-circuit $2: fr8-ifcname The circuit enters the inactive state. |
||
frNotification9 | 1.3.6.1.4.1.2007.1.4.92.2.0.9 |
Notification of Event FR.9 Message: 'Circuit is unavailable PVC = $1, on interface $2' Parameters list: $1: fr9-circuit $2: fr9-ifcname The circuit is no longer available on the network. |
||
frNotification10 | 1.3.6.1.4.1.2007.1.4.92.2.0.10 |
Notification of Event FR.10 Message: 'Circuit is available PVC = $1, on interface $2' Parameters list: $1: fr10-circuit $2: fr10-ifcname The circuit is now available on the network. |
||
frNotification11 | 1.3.6.1.4.1.2007.1.4.92.2.0.11 |
Notification of Event FR.11 Message: 'LMI sequence number exchange requested, last received sequence = $1, current transmit sequence = $2, on interface $3' Parameters list: $1: fr11-rcvseq $2: fr11-xmtseq $3: fr11-ifcname A LMI sequence number exchange has been requested. |
||
frNotification12 | 1.3.6.1.4.1.2007.1.4.92.2.0.12 |
Notification of Event FR.12 Message: 'LMI Status Enquiry requested on interface $1' Parameters list: $1: fr12-ifcname A LMI full Status Enquiry has been requested. |
||
frNotification13 | 1.3.6.1.4.1.2007.1.4.92.2.0.13 |
Notification of Event FR.13 Message: 'LMI solicited Status Enquiry response had been received on interface $1' Parameters list: $1: fr13-ifcname A solicited LMI Status Enquiry response has been received. |
||
frNotification14 | 1.3.6.1.4.1.2007.1.4.92.2.0.14 |
Notification of Event FR.14 Message: 'LMI Full Status Enquiry response had been received on interface $1' Parameters list: $1: fr14-ifcname A LMI full Status Enquiry response has been received. |
||
frNotification15 | 1.3.6.1.4.1.2007.1.4.92.2.0.15 |
Notification of Event FR.15 Message: 'Modem status changed DCD = $1 CTS = $2 on interface $3' Parameters list: $1: fr15-dcd $2: fr15-cts $3: fr15-ifcname A modem status change has occurred. The present state is described. |
||
frNotification16 | 1.3.6.1.4.1.2007.1.4.92.2.0.16 |
Notification of Event FR.16 Message: 'Multicast frame transmitted PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr16-circuit $2: fr16-protocol $3: fr16-ifcname A multicast frame had been transmitted on the FR interface. |
||
frNotification17 | 1.3.6.1.4.1.2007.1.4.92.2.0.17 |
Notification of Event FR.17 Message: 'Circuit remains congested in the outbound direction PVC = $1, on interface $2' Parameters list: $1: fr17-circuit $2: fr17-ifcname The circuit is remaining in the outbound congested state toward the network. |
||
frNotification18 | 1.3.6.1.4.1.2007.1.4.92.2.0.18 |
Notification of Event FR.18 Message: 'CIR exceeded, transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr18-circuit $2: fr18-protocol $3: fr18-ifcname A protocol frame had been discarded due to the PVC exceeding the CIR on the circuit. |
||
frNotification19 | 1.3.6.1.4.1.2007.1.4.92.2.0.19 |
Notification of Event FR.19 Message: 'A disallowed orphan circuit not statically configured has been ignored PVC = $1, on interface $2' Parameters list: $1: fr19-circuit $2: fr19-ifcname The LMI signalled present and active a circuit which had not been statically configured or allowed. |
||
frNotification20 | 1.3.6.1.4.1.2007.1.4.92.2.0.20 |
Notification of Event FR.20 Message: 'The total circuits allowed has been exceeded, an orphan circuit has been ignored PVC = $1, on interface $2' Parameters list: $1: fr20-circuit $2: fr20-ifcname The LMI signalled present and active a circuit which cannot join the interface, maximum circuits have been exceeded. |
||
frNotification21 | 1.3.6.1.4.1.2007.1.4.92.2.0.21 |
Notification of Event FR.21 Message: 'No available memory for orphan circuit, the circuit has been ignored PVC = $1, on interface $2' Parameters list: $1: fr21-circuit $2: fr21-ifcname The LMI signalled present and active a circuit which cannot join the interface, memory is unavailable. |
||
frNotification22 | 1.3.6.1.4.1.2007.1.4.92.2.0.22 |
Notification of Event FR.22 Message: 'Unsupported LMI information element, type = $1 on interface $2' Parameters list: $1: fr22-type $2: fr22-ifcname An unsupported management information element has been encountered. |
||
frNotification23 | 1.3.6.1.4.1.2007.1.4.92.2.0.23 |
Notification of Event FR.23 Message: 'Unsupported LMI message type, type encountered = $1, on interface $2' Parameters list: $1: fr23-type $2: fr23-ifcname An unsupported management message has been encountered. |
||
frNotification24 | 1.3.6.1.4.1.2007.1.4.92.2.0.24 |
Notification of Event FR.24 Message: 'A multicast circuit has joined the network PVC = $1, in multicast group = $2 on interface $3' Parameters list: $1: fr24-circuit $2: fr24-group $3: fr24-ifcname The LMI signalled present and active a multicast circuit. |
||
frNotification25 | 1.3.6.1.4.1.2007.1.4.92.2.0.25 |
Notification of Event FR.25 Message: 'An multicast circuit has left the network PVC = $1, from multicast group = $2 on interface $3' Parameters list: $1: fr25-circuit $2: fr25-group $3: fr25-ifcname The LMI signalled present and active a multicast circuit. |
||
frNotification26 | 1.3.6.1.4.1.2007.1.4.92.2.0.26 |
Notification of Event FR.26 Message: 'Unsupported Network Layer Protocol ID, type = $1 from PVC = $2 size $3 bytes on interface $4' Parameters list: $1: fr26-type $2: fr26-circuit $3: fr26-size $4: fr26-ifcname An unsupported network layer protocol NLPID has been encountered. |
||
frNotification27 | 1.3.6.1.4.1.2007.1.4.92.2.0.27 |
Notification of Event FR.27 Message: 'Unsupported ethernet type, type = $1 from PVC = $2 size $3 bytes on interface $4' Parameters list: $1: fr27-type $2: fr27-circuit $3: fr27-size $4: fr27-ifcname An unsupported Ethernet type has been encountered. |
||
frNotification28 | 1.3.6.1.4.1.2007.1.4.92.2.0.28 |
Notification of Event FR.28 Message: 'An unsupported multicast circuit has been ignored, PVC = $1, in multicast group = $2 on interface $3' Parameters list: $1: fr28-circuit $2: fr28-group $3: fr28-ifcname The LMI signalled present and active a multicast circuit that is not supported on the interface. |
||
frNotification29 | 1.3.6.1.4.1.2007.1.4.92.2.0.29 |
Notification of Event FR.29 Message: 'Data received on invalid or nonconfigured circuit, PVC = $1 on interface $2' Parameters list: $1: fr29-circuit $2: fr29-ifcname Data has been received on a circuit not configured or learned dynamically but not yet active on network. |
||
frNotification30 | 1.3.6.1.4.1.2007.1.4.92.2.0.30 |
Notification of Event FR.30 Message: 'LMI sequence number exchange received, last received sequence = $1 current transmit sequence = $2, on interface $3' Parameters list: $1: fr30-rcvseq $2: fr30-xmtseq $3: fr30-ifcname A LMI sequence number exchange has been received. |
||
frNotification31 | 1.3.6.1.4.1.2007.1.4.92.2.0.31 |
Notification of Event FR.31 Message: 'LMI unsolicited single Status Update had been received on interface $1' Parameters list: $1: fr31-ifcname An LMI unsolicited single status update message has been received. |
||
frNotification32 | 1.3.6.1.4.1.2007.1.4.92.2.0.32 |
Notification of Event FR.32 Message: 'Circuit address length less than the 2 octet minimum received on interface $1' Parameters list: $1: fr32-ifcname A frame containing less than the 2 octet minimum address length had been encountered. |
||
frNotification33 | 1.3.6.1.4.1.2007.1.4.92.2.0.33 |
Notification of Event FR.33 Message: 'Circuit address length greater than the 2 octet maximum received on interface $1' Parameters list: $1: fr33-ifcname A frame containing greater than the 2 octet maximum address length supported had been encountered. Currently, only 2 octet addressing is supported. |
||
frNotification34 | 1.3.6.1.4.1.2007.1.4.92.2.0.34 |
Notification of Event FR.34 Message: 'Circuit status update message contained a reserved management channel address, PVC = $1, on interface $2' Parameters list: $1: fr34-circuit $2: fr34-ifcname The LMI status message contained a reserved management channel address. |
||
frNotification35 | 1.3.6.1.4.1.2007.1.4.92.2.0.35 |
Notification of Event FR.35 Message: 'Unsupported Link Layer Control frame encountered, type = $1 from PVC = $2 on interface $3' Parameters list: $1: fr35-type $2: fr35-circuit $3: fr35-ifcname An unsupported link layer control frame encountered. |
||
frNotification36 | 1.3.6.1.4.1.2007.1.4.92.2.0.36 |
Notification of Event FR.36 Message: 'Unsupported layer management protocol descriptor encountered, type = $1 on interface $2' Parameters list: $1: fr36-type $2: fr36-ifcname An unsupported network layer protocol descriptor has been encountered. |
||
frNotification37 | 1.3.6.1.4.1.2007.1.4.92.2.0.37 |
Notification of Event FR.37 Message: 'Unsupported layer management call reference encountered on interface $1' Parameters list: $1: fr37-ifcname An unsupported network layer call reference field has been encountered. |
||
frNotification38 | 1.3.6.1.4.1.2007.1.4.92.2.0.38 |
Notification of Event FR.38 Message: 'No lock shift encountered in received ANSI LMI message on interface $1' Parameters list: $1: fr38-ifcname The received ANSI management frame did not include required locking shift information element. |
||
frNotification39 | 1.3.6.1.4.1.2007.1.4.92.2.0.39 |
Notification of Event FR.39 Message: 'Incorrect formated information element encountered on interface $1' Parameters list: $1: fr39-ifcname The received management frame information element was incorrectly formated. |
||
frNotification40 | 1.3.6.1.4.1.2007.1.4.92.2.0.40 |
Notification of Event FR.40 Message: 'LMI receive sequence number in error, receive sequence = $1 expected sequence = $2, on interface $3' Parameters list: $1: fr40-rcvseq $2: fr40-xmtseq $3: fr40-ifcname An incorrect LMI receive sequence number has been received. |
||
frNotification41 | 1.3.6.1.4.1.2007.1.4.92.2.0.41 |
Notification of Event FR.41 Message: 'An circuit has been removed from the network PVC = $1, on interface $2' Parameters list: $1: fr41-circuit $2: fr41-ifcname The LMI failed to signal the mentioned circuit is last network status update message. Circuit assumed removed from network. |
||
frNotification42 | 1.3.6.1.4.1.2007.1.4.92.2.0.42 |
Notification of Event FR.42 Message: 'Circuit inbound congestion PVC = $1, on interface $2' Parameters list: $1: fr42-circuit $2: fr42-ifcname The circuit is now experiencing congestion in the inbound direction. |
||
frNotification43 | 1.3.6.1.4.1.2007.1.4.92.2.0.43 |
Notification of Event FR.43 Message: 'Incorrect formatted address header for LMI packet encountered on interface $1' Parameters list: $1: fr43-ifcname The address header on received management frame had BECN, FECN, DE or CR bits set. |
||
frNotification44 | 1.3.6.1.4.1.2007.1.4.92.2.0.44 |
Notification of Event FR.44 Message: 'Unsolicited LMI Link Integrity Verification received on interface $1' Parameters list: $1: fr44-ifcname LMI Link Integrity Verification message was received from the network without the router polling for it. |
||
frNotification45 | 1.3.6.1.4.1.2007.1.4.92.2.0.45 |
Notification of Event FR.45 Message: 'Unsolicited LMI FULL STATUS response received on interface $1' Parameters list: $1: fr45-ifcname LMI Full Status message was received from the network without the router polling for it. |
||
frNotification46 | 1.3.6.1.4.1.2007.1.4.92.2.0.46 |
Notification of Event FR.46 Message: 'DROP: Bridging not enabled on PVC=$1, on interface $2' Parameters list: $1: fr46-circuit $2: fr46-ifcname A frame was received of a bridge type defined in RFC 1490. However, since bridging has not been enabled on this circuit, frame is being discarded. |
||
frNotification47 | 1.3.6.1.4.1.2007.1.4.92.2.0.47 |
Notification of Event FR.47 Message: 'DROP: Bridge port not forwarding on PVC=$1, on interface $2' Parameters list: $1: fr47-circuit $2: fr47-ifcname A bridge frame is being discarded as a bridge port is not in forwarding state. |
||
frNotification48 | 1.3.6.1.4.1.2007.1.4.92.2.0.48 |
Notification of Event FR.48 Message: 'DROP: $1->$2, Frame to bridge port behavior mismatch on PVC=$3, on interface $4' Parameters list: $1: fr48-source-mac $2: fr48-dest-mac $3: fr48-circuit $4: fr48-ifcname A bridged frame has been received and is being discarded due to mismatch in the frame type versus the bridge port behavior. |
||
frNotification49 | 1.3.6.1.4.1.2007.1.4.92.2.0.49 |
Notification of Event FR.49 Message: 'Unsupported bridge frame type = $1 from PVC = $2 on interface $3' Parameters list: $1: fr49-type $2: fr49-circuit $3: fr49-ifcname An unsupported bridge frame type has been encountered. |
||
frNotification50 | 1.3.6.1.4.1.2007.1.4.92.2.0.50 |
Notification of Event FR.50 Message: 'Unrecognized outgoing bridge frame type = $1 on PVC = $2 on interface $3' Parameters list: $1: fr50-type $2: fr50-circuit $3: fr50-ifcname An unrecognized outgoing bridge frame type. Bridge has asked the Frame Relay interface to send out a frame whose type cannot be translated into encapsulation defined in RFC 1490. |
||
frNotification51 | 1.3.6.1.4.1.2007.1.4.92.2.0.51 |
Notification of Event FR.51 Message: 'Transmit frame discarded PVC = $1 protocol type = $2, on interface $3' Parameters list: $1: fr51-circuit $2: fr51-protocol $3: fr51-ifcname A protocol frame has been discarded because it could not be queued for transmission. |
||
frNotification52 | 1.3.6.1.4.1.2007.1.4.92.2.0.52 |
Notification of Event FR.52 Message: 'LMI send sequence number in error, sequence = $1, on interface $2' Parameters list: $1: fr52-sndseq $2: fr52-ifcname An LMI send sequence number of 0 has been received. |
||
frNotification53 | 1.3.6.1.4.1.2007.1.4.92.2.0.53 |
Notification of Event FR.53 Message: 'FRF.12 $1 header $2 on PVC = $3 size $4 bytes, on interface $5' Parameters list: $1: fr53-message $2: fr53-header $3: fr53-circuit $4: fr53-size $5: fr53-ifcname A FRF.12 fragment is processed and a event is reported. |