TELDAT-TRAP-ATM-MIB: View SNMP OID List / Download MIB

VENDOR: TELDAT, S.A.


 Home MIB: TELDAT-TRAP-ATM-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 atmTrapsMIB 1.3.6.1.4.1.2007.1.4.136
This Module Information Base file is defined for managing received SNMP notifications generated by the ATM event subsystem.
         atmEventsGroup 1.3.6.1.4.1.2007.1.4.136.1
             atmEventObjects1 1.3.6.1.4.1.2007.1.4.136.1.1
Event ATM.1 An ATM cell has been received.
                 atm1_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.1.1 displaystring no-access
Parameter 'mnemonic' in event ATM.1
                 atm1_vpi 1.3.6.1.4.1.2007.1.4.136.1.1.2 integer32 no-access
Parameter 'vpi' in event ATM.1
                 atm1_vci 1.3.6.1.4.1.2007.1.4.136.1.1.3 integer32 no-access
Parameter 'vci' in event ATM.1
                 atm1_data_ptr 1.3.6.1.4.1.2007.1.4.136.1.1.4 integer32 no-access
Parameter 'data-ptr' in event ATM.1
                 atm1_buffer 1.3.6.1.4.1.2007.1.4.136.1.1.5 displaystring no-access
Parameter 'buffer' in event ATM.1
             atmEventObjects2 1.3.6.1.4.1.2007.1.4.136.1.2
Event ATM.2 An AAL5 CPCS frame has been received.
                 atm2_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.2.1 displaystring no-access
Parameter 'mnemonic' in event ATM.2
                 atm2_vpi 1.3.6.1.4.1.2007.1.4.136.1.2.2 integer32 no-access
Parameter 'vpi' in event ATM.2
                 atm2_vci 1.3.6.1.4.1.2007.1.4.136.1.2.3 integer32 no-access
Parameter 'vci' in event ATM.2
                 atm2_data_ptr 1.3.6.1.4.1.2007.1.4.136.1.2.4 integer32 no-access
Parameter 'data-ptr' in event ATM.2
                 atm2_len 1.3.6.1.4.1.2007.1.4.136.1.2.5 integer32 no-access
Parameter 'len' in event ATM.2
                 atm2_buffer 1.3.6.1.4.1.2007.1.4.136.1.2.6 displaystring no-access
Parameter 'buffer' in event ATM.2
             atmEventObjects3 1.3.6.1.4.1.2007.1.4.136.1.3
Event ATM.3 An ATM cell has been transmitted.
                 atm3_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.3.1 displaystring no-access
Parameter 'mnemonic' in event ATM.3
                 atm3_vpi 1.3.6.1.4.1.2007.1.4.136.1.3.2 integer32 no-access
Parameter 'vpi' in event ATM.3
                 atm3_vci 1.3.6.1.4.1.2007.1.4.136.1.3.3 integer32 no-access
Parameter 'vci' in event ATM.3
                 atm3_data_ptr 1.3.6.1.4.1.2007.1.4.136.1.3.4 integer32 no-access
Parameter 'data-ptr' in event ATM.3
                 atm3_buffer 1.3.6.1.4.1.2007.1.4.136.1.3.5 displaystring no-access
Parameter 'buffer' in event ATM.3
             atmEventObjects4 1.3.6.1.4.1.2007.1.4.136.1.4
Event ATM.4 An AAL5 CPCS frame has been transmitted.
                 atm4_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.4.1 displaystring no-access
Parameter 'mnemonic' in event ATM.4
                 atm4_vpi 1.3.6.1.4.1.2007.1.4.136.1.4.2 integer32 no-access
Parameter 'vpi' in event ATM.4
                 atm4_vci 1.3.6.1.4.1.2007.1.4.136.1.4.3 integer32 no-access
Parameter 'vci' in event ATM.4
                 atm4_data_ptr 1.3.6.1.4.1.2007.1.4.136.1.4.4 integer32 no-access
Parameter 'data-ptr' in event ATM.4
                 atm4_len 1.3.6.1.4.1.2007.1.4.136.1.4.5 integer32 no-access
Parameter 'len' in event ATM.4
                 atm4_buffer 1.3.6.1.4.1.2007.1.4.136.1.4.6 displaystring no-access
Parameter 'buffer' in event ATM.4
             atmEventObjects5 1.3.6.1.4.1.2007.1.4.136.1.5
Event ATM.5 Detailed info about cell reception.
                 atm5_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.5.1 displaystring no-access
Parameter 'mnemonic' in event ATM.5
                 atm5_vpi 1.3.6.1.4.1.2007.1.4.136.1.5.2 integer32 no-access
Parameter 'vpi' in event ATM.5
                 atm5_vci 1.3.6.1.4.1.2007.1.4.136.1.5.3 integer32 no-access
Parameter 'vci' in event ATM.5
                 atm5_data_ptr 1.3.6.1.4.1.2007.1.4.136.1.5.4 integer32 no-access
Parameter 'data-ptr' in event ATM.5
                 atm5_descr 1.3.6.1.4.1.2007.1.4.136.1.5.5 displaystring no-access
Parameter 'descr' in event ATM.5
             atmEventObjects6 1.3.6.1.4.1.2007.1.4.136.1.6
Event ATM.6 Detailed info about AAL5 CPCS frame reception.
                 atm6_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.6.1 displaystring no-access
Parameter 'mnemonic' in event ATM.6
                 atm6_vpi 1.3.6.1.4.1.2007.1.4.136.1.6.2 integer32 no-access
Parameter 'vpi' in event ATM.6
                 atm6_vci 1.3.6.1.4.1.2007.1.4.136.1.6.3 integer32 no-access
Parameter 'vci' in event ATM.6
                 atm6_data_ptr 1.3.6.1.4.1.2007.1.4.136.1.6.4 integer32 no-access
Parameter 'data-ptr' in event ATM.6
                 atm6_descr 1.3.6.1.4.1.2007.1.4.136.1.6.5 displaystring no-access
Parameter 'descr' in event ATM.6
             atmEventObjects7 1.3.6.1.4.1.2007.1.4.136.1.7
Event ATM.7 Detailed info about cell transmission.
                 atm7_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.7.1 displaystring no-access
Parameter 'mnemonic' in event ATM.7
                 atm7_vpi 1.3.6.1.4.1.2007.1.4.136.1.7.2 integer32 no-access
Parameter 'vpi' in event ATM.7
                 atm7_vci 1.3.6.1.4.1.2007.1.4.136.1.7.3 integer32 no-access
Parameter 'vci' in event ATM.7
                 atm7_data_ptr 1.3.6.1.4.1.2007.1.4.136.1.7.4 integer32 no-access
Parameter 'data-ptr' in event ATM.7
                 atm7_descr 1.3.6.1.4.1.2007.1.4.136.1.7.5 displaystring no-access
Parameter 'descr' in event ATM.7
             atmEventObjects8 1.3.6.1.4.1.2007.1.4.136.1.8
Event ATM.8 Detailed info about AAL5 CPCS frame transmission.
                 atm8_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.8.1 displaystring no-access
Parameter 'mnemonic' in event ATM.8
                 atm8_vpi 1.3.6.1.4.1.2007.1.4.136.1.8.2 integer32 no-access
Parameter 'vpi' in event ATM.8
                 atm8_vci 1.3.6.1.4.1.2007.1.4.136.1.8.3 integer32 no-access
Parameter 'vci' in event ATM.8
                 atm8_data_ptr 1.3.6.1.4.1.2007.1.4.136.1.8.4 integer32 no-access
Parameter 'data-ptr' in event ATM.8
                 atm8_descr 1.3.6.1.4.1.2007.1.4.136.1.8.5 displaystring no-access
Parameter 'descr' in event ATM.8
             atmEventObjects9 1.3.6.1.4.1.2007.1.4.136.1.9
Event ATM.9 A transmission request has been rejected.
                 atm9_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.9.1 displaystring no-access
Parameter 'mnemonic' in event ATM.9
                 atm9_vpi 1.3.6.1.4.1.2007.1.4.136.1.9.2 integer32 no-access
Parameter 'vpi' in event ATM.9
                 atm9_vci 1.3.6.1.4.1.2007.1.4.136.1.9.3 integer32 no-access
Parameter 'vci' in event ATM.9
                 atm9_data_ptr 1.3.6.1.4.1.2007.1.4.136.1.9.4 integer32 no-access
Parameter 'data-ptr' in event ATM.9
                 atm9_len 1.3.6.1.4.1.2007.1.4.136.1.9.5 integer32 no-access
Parameter 'len' in event ATM.9
                 atm9_descr 1.3.6.1.4.1.2007.1.4.136.1.9.6 displaystring no-access
Parameter 'descr' in event ATM.9
             atmEventObjects10 1.3.6.1.4.1.2007.1.4.136.1.10
Event ATM.10 Unexpected software behaviour.
                   atm10_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.10.1 displaystring no-access
Parameter 'mnemonic' in event ATM.10
                   atm10_soft_descr 1.3.6.1.4.1.2007.1.4.136.1.10.2 displaystring no-access
Parameter 'soft-descr' in event ATM.10
                   atm10_event_descr 1.3.6.1.4.1.2007.1.4.136.1.10.3 displaystring no-access
Parameter 'event-descr' in event ATM.10
             atmEventObjects11 1.3.6.1.4.1.2007.1.4.136.1.11
Event ATM.11 The frame received has been detected as errored at subinterface level.
                   atm11_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.11.1 displaystring no-access
Parameter 'mnemonic' in event ATM.11
                   atm11_rsn_descr 1.3.6.1.4.1.2007.1.4.136.1.11.2 displaystring no-access
Parameter 'rsn-descr' in event ATM.11
             atmEventObjects12 1.3.6.1.4.1.2007.1.4.136.1.12
Event ATM.12 Event at ATM interface level: up, down.
                   atm12_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.12.1 displaystring no-access
Parameter 'mnemonic' in event ATM.12
                   atm12_event_descr 1.3.6.1.4.1.2007.1.4.136.1.12.2 displaystring no-access
Parameter 'event-descr' in event ATM.12
             atmEventObjects13 1.3.6.1.4.1.2007.1.4.136.1.13
Event ATM.13 Event at ATM VCC level.
                   atm13_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.13.1 displaystring no-access
Parameter 'mnemonic' in event ATM.13
                   atm13_vpi 1.3.6.1.4.1.2007.1.4.136.1.13.2 integer32 no-access
Parameter 'vpi' in event ATM.13
                   atm13_vci 1.3.6.1.4.1.2007.1.4.136.1.13.3 integer32 no-access
Parameter 'vci' in event ATM.13
                   atm13_event_descr 1.3.6.1.4.1.2007.1.4.136.1.13.4 displaystring no-access
Parameter 'event-descr' in event ATM.13
             atmEventObjects14 1.3.6.1.4.1.2007.1.4.136.1.14
Event ATM.14 An AAL5 SAR cell has been transmitted.
                   atm14_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.14.1 displaystring no-access
Parameter 'mnemonic' in event ATM.14
                   atm14_vpi 1.3.6.1.4.1.2007.1.4.136.1.14.2 integer32 no-access
Parameter 'vpi' in event ATM.14
                   atm14_vci 1.3.6.1.4.1.2007.1.4.136.1.14.3 integer32 no-access
Parameter 'vci' in event ATM.14
                   atm14_data_ptr 1.3.6.1.4.1.2007.1.4.136.1.14.4 integer32 no-access
Parameter 'data-ptr' in event ATM.14
                   atm14_details 1.3.6.1.4.1.2007.1.4.136.1.14.5 displaystring no-access
Parameter 'details' in event ATM.14
             atmEventObjects15 1.3.6.1.4.1.2007.1.4.136.1.15
Event ATM.15 Event related to the SAR unit
                   atm15_mnemonic 1.3.6.1.4.1.2007.1.4.136.1.15.1 displaystring no-access
Parameter 'mnemonic' in event ATM.15
                   atm15_event_descr 1.3.6.1.4.1.2007.1.4.136.1.15.2 displaystring no-access
Parameter 'event-descr' in event ATM.15
         atmNotifications 1.3.6.1.4.1.2007.1.4.136.2
             atmNotificationsPrefix 1.3.6.1.4.1.2007.1.4.136.2.0
                 atmNotification1 1.3.6.1.4.1.2007.1.4.136.2.0.1
Notification of Event ATM.1 Message: '$1 ATM cell received ($2..$3) data=$4: $5' Parameters list: $1: atm1-mnemonic $2: atm1-vpi $3: atm1-vci $4: atm1-data-ptr $5: atm1-buffer An ATM cell has been received.
                 atmNotification2 1.3.6.1.4.1.2007.1.4.136.2.0.2
Notification of Event ATM.2 Message: '$1 AAL5 CPCS frame Received ($2..$3) data=$4 len=$5: $6' Parameters list: $1: atm2-mnemonic $2: atm2-vpi $3: atm2-vci $4: atm2-data-ptr $5: atm2-len $6: atm2-buffer An AAL5 CPCS frame has been received.
                 atmNotification3 1.3.6.1.4.1.2007.1.4.136.2.0.3
Notification of Event ATM.3 Message: '$1 ATM cell transmission ($2..$3) data=$4: $5' Parameters list: $1: atm3-mnemonic $2: atm3-vpi $3: atm3-vci $4: atm3-data-ptr $5: atm3-buffer An ATM cell has been transmitted.
                 atmNotification4 1.3.6.1.4.1.2007.1.4.136.2.0.4
Notification of Event ATM.4 Message: '$1 AAL5 CPCS frame transmission ($2..$3) data=$4 len=$5: $6' Parameters list: $1: atm4-mnemonic $2: atm4-vpi $3: atm4-vci $4: atm4-data-ptr $5: atm4-len $6: atm4-buffer An AAL5 CPCS frame has been transmitted.
                 atmNotification5 1.3.6.1.4.1.2007.1.4.136.2.0.5
Notification of Event ATM.5 Message: '$1 ATM cell received ($2..$3) data=$4 $5' Parameters list: $1: atm5-mnemonic $2: atm5-vpi $3: atm5-vci $4: atm5-data-ptr $5: atm5-descr Detailed info about cell reception.
                 atmNotification6 1.3.6.1.4.1.2007.1.4.136.2.0.6
Notification of Event ATM.6 Message: '$1 AAL5 CPCS frame received ($2..$3) data=$4 $5' Parameters list: $1: atm6-mnemonic $2: atm6-vpi $3: atm6-vci $4: atm6-data-ptr $5: atm6-descr Detailed info about AAL5 CPCS frame reception.
                 atmNotification7 1.3.6.1.4.1.2007.1.4.136.2.0.7
Notification of Event ATM.7 Message: '$1 ATM cell transmission ($2..$3) data=$4 $5' Parameters list: $1: atm7-mnemonic $2: atm7-vpi $3: atm7-vci $4: atm7-data-ptr $5: atm7-descr Detailed info about cell transmission.
                 atmNotification8 1.3.6.1.4.1.2007.1.4.136.2.0.8
Notification of Event ATM.8 Message: '$1 AAL5 CPCS frame transmission ($2..$3) data=$4 $5' Parameters list: $1: atm8-mnemonic $2: atm8-vpi $3: atm8-vci $4: atm8-data-ptr $5: atm8-descr Detailed info about AAL5 CPCS frame transmission.
                 atmNotification9 1.3.6.1.4.1.2007.1.4.136.2.0.9
Notification of Event ATM.9 Message: '$1 Transmission rejected ($2..$3) data=$4 len=$5 rsn=$6' Parameters list: $1: atm9-mnemonic $2: atm9-vpi $3: atm9-vci $4: atm9-data-ptr $5: atm9-len $6: atm9-descr A transmission request has been rejected.
                 atmNotification10 1.3.6.1.4.1.2007.1.4.136.2.0.10
Notification of Event ATM.10 Message: '$1 Unexpected $2 software event $3' Parameters list: $1: atm10-mnemonic $2: atm10-soft-descr $3: atm10-event-descr Unexpected software behaviour.
                 atmNotification11 1.3.6.1.4.1.2007.1.4.136.2.0.11
Notification of Event ATM.11 Message: '$1 reception with error Reason=$2' Parameters list: $1: atm11-mnemonic $2: atm11-rsn-descr The frame received has been detected as errored at subinterface level.
                 atmNotification12 1.3.6.1.4.1.2007.1.4.136.2.0.12
Notification of Event ATM.12 Message: '$1 $2' Parameters list: $1: atm12-mnemonic $2: atm12-event-descr Event at ATM interface level: up, down.
                 atmNotification13 1.3.6.1.4.1.2007.1.4.136.2.0.13
Notification of Event ATM.13 Message: '$1 VPI=$2 VCI=$3 $4' Parameters list: $1: atm13-mnemonic $2: atm13-vpi $3: atm13-vci $4: atm13-event-descr Event at ATM VCC level.
                 atmNotification14 1.3.6.1.4.1.2007.1.4.136.2.0.14
Notification of Event ATM.14 Message: '$1 AAL5 SAR cell transmission ($2..$3) data=$4 $5' Parameters list: $1: atm14-mnemonic $2: atm14-vpi $3: atm14-vci $4: atm14-data-ptr $5: atm14-details An AAL5 SAR cell has been transmitted.
                 atmNotification15 1.3.6.1.4.1.2007.1.4.136.2.0.15
Notification of Event ATM.15 Message: '$1 $2' Parameters list: $1: atm15-mnemonic $2: atm15-event-descr Event related to the SAR unit