Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 telProdNpMonInterfSSL 1.3.6.1.4.1.2007.4.1.2.2.2.15
       telProdNpMonIfcSSLGlobalTable 1.3.6.1.4.1.2007.4.1.2.2.2.15.1 no-access
This table contains general information about synchronous serial line interfaces. The interface number determines the entry number.
           telProdNpMonIfcSSLGlobalEntry 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1 no-access
Each table entry contains the interface number of the related node, which is the index used to go over the table, the type of physical driver (DTE or DCE), the line speed, the time when the last port reset ocurred and variables to indicate if the SCC loopback mode or echo mode are active and if the DTE driver uses internal clocks.
               telProdNpMonIfcSSLGloIndex 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.1 integer read-only
The node interface number, which indicates the corresponding table entry (it is the table index).
               telProdNpMonIfcSSLGloDriverType 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.2 displaystring read-only
Type of physical driver: (1) DCE, (2) DTE. This variable is a string that indicates the driver.
               telProdNpMonIfcSSLGloLineSpeed 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.3 integer read-only
Line speed, in bits per second. The value 0 indicates speed unknown.
               telProdNpMonIfcSSLGloLastResetWeek 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.4 integer read-only
Weeks passed since the last reset of the port.
               telProdNpMonIfcSSLGloLastResetDay 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.5 integer read-only
Days passed since the last reset of the port: the remaining days that we get after counting the number of weeks that are not enough to form a week, this implies that the value of the variable must be under 7.
               telProdNpMonIfcSSLGloLastResetHour 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.6 integer read-only
Hours passed since the last reset of the port. If it has passed more than a week, this variable indicates the number of hours to be added to the number of weeks and days, and its value should be under 24 so as not form a complete day.
               telProdNpMonIfcSSLGloLastResetMin 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.7 integer read-only
Minutes passed since the last reset of the port. This variable indicates the number of minutes since the last hour added to the hour counter.
               telProdNpMonIfcSSLGloLastResetSec 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.8 integer read-only
Seconds passed since the last reset of the port. The total time passed will be calculated by adding weeks, days, hours, minutes and seconds since the last reset.
               telProdNpMonIfcSSLGloLoopback 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.9 integer read-only
This variable indicates if SCC loopback mode is active: transmitter is connected internally to the receiver. Enumeration: 'active': 1, 'inactive': 2.
               telProdNpMonIfcSSLGloEcho 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.10 integer read-only
This variable indicates if SCC echo mode is active: transmitter resends received data. Enumeration: 'active': 1, 'inactive': 2.
               telProdNpMonIfcSSLGloDTEIntClocks 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.11 integer read-only
This variable indicates if DTE driver uses internal clocks. Enumeration: 'yes': 1, 'no': 2.
               telProdNpMonIfcSSLGloIgnoreCD 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.12 integer read-only
This variable indicates if CD signal state is ignored. Enumeration: 'yes': 1, 'no': 2.
               telProdNpMonIfcSSLGloDisconnectCD 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.13 integer read-only
This variable indicates if CD signal is disconnected from internal hardware. Enumeration: 'yes': 1, 'no': 2.
               telProdNpMonIfcSSLGloIgnoreCTS 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.14 integer read-only
This variable indicates if CTS signal state is ignored. Enumeration: 'yes': 1, 'no': 2.
               telProdNpMonIfcSSLGloIgnoreDSR 1.3.6.1.4.1.2007.4.1.2.2.2.15.1.1.15 integer read-only
This variable indicates if DSR signal state is ignored. Enumeration: 'yes': 1, 'no': 2.
       telProdNpMonIfcSSLRS232Table 1.3.6.1.4.1.2007.4.1.2.2.2.15.2 no-access
This table contains the signals or circuits RS232. It shows wether the signals are active or not. The entry number is determined by the interface number considered.
           telProdNpMonIfcSSLRS232Entry 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1 no-access
Each entry contains the interface number of the node considered, which will be the first index used to go over the table, the order number of the circuit inside that interface (second index), which must be between 1 and a maximum value that depends on the conector type (the highest value will be 7), the circuit number (105, 106, 107, 108, 109, 125, 141), its name (RTS, CTS, DSR, DTR, DCD, RI, LL) and wether it is active or not.
               telProdNpMonIfcSSLRS232IfcIndex 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.1 integer read-only
Synchronous serial line interface number of the node. It is the first table index.
               telProdNpMonIfcSSLRS232CircIndex 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.2 integer read-only
Second table index. This number goes from 1 to the number of circuits of this type allowed, which varies with the conector type.
               telProdNpMonIfcSSLRS232Circuit 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.3 integer read-only
RS232 circuit number. Values accepted are 105, 106, 107, 108, 109, 125 y 141.
               telProdNpMonIfcSSLRS232Nickname 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.4 displaystring read-only
Circuit name.
               telProdNpMonIfcSSLRS232State 1.3.6.1.4.1.2007.4.1.2.2.2.15.2.1.5 displaystring read-only
State of (circuit) signals: on, off or unknown.
       telProdNpMonIfcSSLFramesTable 1.3.6.1.4.1.2007.4.1.2.2.2.15.3 no-access
This table contains a counter of outgoing frames and a counter of bugs in ingoing frames. The entry number is determined by the interface number (table index).
           telProdNpMonIfcSSLFramesEntry 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1 no-access
Each entry contains the node interface number, which is the index used to go over the table, a variable that shows the last output obtained when the user tried to delete the table (get operations) or performs the deletion (set operations), CRC errors in incoming frames, alignment errors, lost incoming frames due to overrun, too long frames, aborted frames, number of errors due to DMA/FIFO overrun, number of DMA/FIFO underrun in outgoing frames and aborted outputs sent.
               telProdNpMonIfcSSLFramesIndex 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.1 integer read-only
Interface number of the node, that shows the corresponding table entry (it is the index).
               telProdNpMonIfcSSLFramesClear 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.2 integer read-write
This variable when is read shows the output from the last table delete attempt: the value is 2 if the deletion was performed succesfully, 3 if an error ocurred and 4 for an undefined result, that means that nobody has tried to delete the table yet. In set operations, the value 1 (it is the only value that can be assigned by a writing operation) causes a table deletion: frame counters are set to 0. Enumeration: 'error': 3, 'ok': 2, 'undefined': 4, 'delete': 1.
               telProdNpMonIfcSSLFramesCRCError 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.3 counter read-only
Number of frames with CRC errors.
               telProdNpMonIfcSSLFramesAlignment 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.4 counter read-only
Number of incoming frames with alignment errors.
               telProdNpMonIfcSSLFramesMissed 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.5 counter read-only
Number of incoming frames lost due to overrun.
               telProdNpMonIfcSSLFramesTooLong 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.6 counter read-only
Number of incoming frames too long.
               telProdNpMonIfcSSLFramesAborted 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.7 counter read-only
Number of incoming frames aborted.
               telProdNpMonIfcSSLFramesOverrun 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.8 counter read-only
Number of DMA/FIFO overrun.
               telProdNpMonIfcSSLFramesUnderrun 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.9 counter read-only
Number of DMA/FIFO underrun.
               telProdNpMonIfcSSLFramesTxAbort 1.3.6.1.4.1.2007.4.1.2.2.2.15.3.1.10 counter read-only
Number of aborted outputs sent.