SWITCH-MIB: View SNMP OID List / Download MIB

VENDOR: PLAINTREE SYSTEMS INC.


 Home MIB: SWITCH-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 vendor 1.3.6.1.4.1.295
         ethernetSwitchingDevice 1.3.6.1.4.1.295.3
             deviceHardware 1.3.6.1.4.1.295.3.1
                 deviceChassis 1.3.6.1.4.1.295.3.1.1
                 devicePort 1.3.6.1.4.1.295.3.1.2
                     ethernetPort 1.3.6.1.4.1.295.3.1.2.1
                     waveBusPort 1.3.6.1.4.1.295.3.1.2.2
                     fddiPort 1.3.6.1.4.1.295.3.1.2.3
             deviceSoftware 1.3.6.1.4.1.295.3.2
                 deviceInfo 1.3.6.1.4.1.295.3.2.1
                     chassisTable 1.3.6.1.4.1.295.3.2.1.1 no-access
Information about the unit.
                         chassisEntry 1.3.6.1.4.1.295.3.2.1.1.1 no-access
Identification information about the unit.
                             chassisProductCode 1.3.6.1.4.1.295.3.2.1.1.1.1 displaystring read-only
An ASCII string giving the product code of the unit.
                             chassisSerialNumber 1.3.6.1.4.1.295.3.2.1.1.1.2 displaystring read-only
An ASCII string giving the unit's serial number.
                             chassisPlaceOfManufacture 1.3.6.1.4.1.295.3.2.1.1.1.3 integer read-only
A number identifying where the unit was built. Enumeration: 'ottawa': 1.
                             chassisDateOfManufacture 1.3.6.1.4.1.295.3.2.1.1.1.4 displaystring read-only
An ASCII string giving the date of manufacture of the unit.
                             chassisMacAddress 1.3.6.1.4.1.295.3.2.1.1.1.5 macaddress read-only
The IEEE 802 MAC address of the unit.
                             chassisCodeVersion 1.3.6.1.4.1.295.3.2.1.1.1.6 displaystring read-only
An ASCII string giving the version number of the control software.
                             chassisBpeEnabled 1.3.6.1.4.1.295.3.2.1.1.1.7 integer read-write
Setting this variable to TRUE (1) causes the bridge protocol engine to perform the Spanning Tree Protocol as defined in IEEE802.1d. Setting this variable to FALSE (0) causes the BPE to stop performing the Spanning Tree Protocol. The value of this variable when the unit starts operating is 1.
                             chassisEraseSnmpConfigInfo 1.3.6.1.4.1.295.3.2.1.1.1.8 integer read-write
Setting this variable to TRUE (1) causes the unit to erase its SNMP configuration information both from memory and from permanent store. The unit the requests new configuration information using the BOOTP protocol. Setting this variable to any other value has no effect. This variable will always return 0 when read.
                             chassisRestoreDot1dDefaults 1.3.6.1.4.1.295.3.2.1.1.1.9 integer read-write
Setting this variable to TRUE (1) causes the BPE to restore the default spanning tree values given in the IEEE 802.1d specification. This resets all writeable Bridge MIB variables in the dot1dStp group of the Bridge MIB. Setting the variable to any other value has no effect. This variable will always return 0 when read.
                             chassisPerformReset 1.3.6.1.4.1.295.3.2.1.1.1.10 integer read-write
Setting this variable to TRUE (1) causes the unit to perform a cold restart. As a result of this action a coldRestart trap will be sent. Setting this variable to any other value has no effect. This variable will always return 0 when read.
                             chassisIdentPressed 1.3.6.1.4.1.295.3.2.1.1.1.11 integer read-only
This variable is TRUE (1) if the IDENTIFY button on the chassis has been pressed since the variable was last read. After this variable has been read it will be set to 0.
                             chassisAgeFilterDatabase 1.3.6.1.4.1.295.3.2.1.1.1.12 integer read-write
Setting this variable to FALSE (0) causes the unit to stop aging out entries from its filter database. Setting this variable to TRUE (1) causes the unit to age out filter database entries as defined in IEEE 802.1D. This variable is set to 0 whenever the unit restarts.
                             chassisClearStatistics 1.3.6.1.4.1.295.3.2.1.1.1.13 integer read-write
Setting this variable to TRUE (1) clears the traffic statistics accumulators. Setting this variable to any other value has no effect. The variable always returns 0 when read.
                             chassisTcpKeepAlivesEnabled 1.3.6.1.4.1.295.3.2.1.1.1.14 integer read-write
Setting this variable to TRUE (1) causes keep alive packets to be transmitted on an idle TCP connection. The period of the keep alive packets is defined by the MIB variable chassisTcpKeepAlivePeriod. Setting this variable to FALSE (0) stops keep alives from being transmitted. The default value of this variable is FALSE (0).
                             chassisTcpKeepAlivePeriod 1.3.6.1.4.1.295.3.2.1.1.1.15 integer read-write
This variable defines the time period in seconds between keep alive packets transmitted on an idle TCP connection. This value must be equal to or greater than 30 seconds and less than or equal to 24 hours (86,400) seconds. The MIB value tcpKeepAlivesEnabled must be set TRUE (1) in order for the keep alive packets to be transmitted. The default value of this variable is 2 hours (7,200) seconds.
                             chassisIndex 1.3.6.1.4.1.295.3.2.1.1.1.100 integer read-only
This is a dummy variable which provides a meta-index for the Chassis Information Table.
                     portTable 1.3.6.1.4.1.295.3.2.1.2 no-access
Identification information about the ports.
                         portEntry 1.3.6.1.4.1.295.3.2.1.2.1 no-access
Identification information about a particular port.
                             portIndex 1.3.6.1.4.1.295.3.2.1.2.1.1 integer read-only
The number of the port to which the management information applies.
                             portProductCode 1.3.6.1.4.1.295.3.2.1.2.1.2 displaystring read-only
An ASCII string giving the product code of the card on which this port is located.
                             portSerialNumber 1.3.6.1.4.1.295.3.2.1.2.1.3 displaystring read-only
An ASCII string giving the serial number of the card on which this port is located.
                             portPlaceOfManufacture 1.3.6.1.4.1.295.3.2.1.2.1.4 integer read-only
A number identifying where the card on which this port is located was built. Enumeration: 'ottawa': 1.
                             portDateOfManufacture 1.3.6.1.4.1.295.3.2.1.2.1.5 displaystring read-only
An ASCII string giving the date of manufacture of the card on which this port is located.
                             portState 1.3.6.1.4.1.295.3.2.1.2.1.6 displaystring read-only
An ASCII string giving the port's operational state.
                             portHighSensitivity 1.3.6.1.4.1.295.3.2.1.2.1.7 integer read-write
This variable is only valid if the port is an Ethernet port. If this variable is set to TRUE (1), the receiver of the Ethernet NIC controlling the port is set to high sensitivity. If the variable is set to 0, the port is set to normal sensitivity. If the ports on both ends of the 10BaseT link are set to high sensitivity, the maximum permissable length of the link is increased from 100 meters to 120 meters. Caution: a high sensitivity receiver may be overdriven by transmitters closer than 100 meters. This variable is 0 when the unit is powered up for the first time. Changes to this variable are preserved across system restarts.
                             portRestoreFddiMibDefaults 1.3.6.1.4.1.295.3.2.1.2.1.8 integer read-write
This variable is ony valid if the port is an FDDI station. Setting this variable to TRUE (1) causes the agent to restore the default MIB values given in the ANSI X3T9.5/84-49 Rev 7.2 specification. This resets all writable FDDI MIB variables. Setting the variable to any other value has no effect. This variable will always return 0 when read.
                             portTranslateAllEthertypes 1.3.6.1.4.1.295.3.2.1.2.1.9 integer read-write
This variable is only valid if the port is an FDDI port. If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation Protocol will be applied to frames containing any Ethertypes, not just the ones in the Selective Translation Table. If this variable is set to FALSE (0), the protocol will only be applied to Ethertypes in the translation table.
                             portTxFrames 1.3.6.1.4.1.295.3.2.1.2.1.10 counter read-only
This counter is incremented by one for each frame transmitted to the network segment attached to the port.
                             portRxFrames 1.3.6.1.4.1.295.3.2.1.2.1.11 counter read-only
This counter is incremented by one for each valid frame received from the network segment attached to the port.
                             portFcsErrors 1.3.6.1.4.1.295.3.2.1.2.1.12 counter read-only
This counter is incremented by one for each received frame which failed its FCS check.
                             portFilterDiscards 1.3.6.1.4.1.295.3.2.1.2.1.13 counter read-only
The number of frames received on this port which have been discarded due to the filtering action of the port's bridge circuit.
                             portDelayExceededDiscards 1.3.6.1.4.1.295.3.2.1.2.1.14 counter read-only
The number of frames discarded by this port due to excessive transit delay through the unit. It reports the same value as the object dot1dBasePortDelayExceededDiscards in the Bridge MIB (RFC 1493).
                             portMtuExceededDiscards 1.3.6.1.4.1.295.3.2.1.2.1.15 counter read-only
The number of frames discarded by this port due to excessive size. It is the same value reported in the object dot1dBasePortMtuExceededDiscards in the Bridge MIB (RFC 1493).
                             portFddiTooLongNonIpFrames 1.3.6.1.4.1.295.3.2.1.2.1.16 counter read-only
The number of unfragmentable (non-IP) frames greater than ethernet length (1514 bytes) discarded by this port. This object is valid only for FDDI ports.
                             portConnected 1.3.6.1.4.1.295.3.2.1.2.1.17 integer read-only
The variable is TRUE (1) if the port is connected to a network segment. The variable is FALSE (0) if the port is not connected to a network segment.
                     sttTable 1.3.6.1.4.1.295.3.2.1.3 no-access
The Selective Translation Table as defined in IEEE 802.1h.
                         sttEntry 1.3.6.1.4.1.295.3.2.1.3.1 no-access
One entry in the Selective Translation Table.
                             sttPortIndex 1.3.6.1.4.1.295.3.2.1.3.1.1 integer read-only
The table index - the port number on which the STT resides.
                             sttEthertype1 1.3.6.1.4.1.295.3.2.1.3.1.2 integer read-write
The first Ethertype for which the Bridge Tunnel Encapsulation Protocol should be used.
                             sttEntryValid1 1.3.6.1.4.1.295.3.2.1.3.1.3 integer read-write
If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation Protocol will be applied to frames containing the first Ethertype. If this variable is set to FALSE (0), the protocol will not be applied to the Ethertype.
                             sttEthertype2 1.3.6.1.4.1.295.3.2.1.3.1.4 integer read-write
The second Ethertype for which the Bridge Tunnel Encapsulation Protocol should be used.
                             sttEntryValid2 1.3.6.1.4.1.295.3.2.1.3.1.5 integer read-write
If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation Protocol will be applied to frames containing the second Ethertype. If this variable is set to FALSE (0), the protocol will not be applied to the Ethertype.
                             sttEthertype3 1.3.6.1.4.1.295.3.2.1.3.1.6 integer read-write
The third Ethertype for which the Bridge Tunnel Encapsulation Protocol should be used.
                             sttEntryValid3 1.3.6.1.4.1.295.3.2.1.3.1.7 integer read-write
If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation Protocol will be applied to frames containing the third Ethertype. If this variable is set to FALSE (0), the protocol will not be applied to the Ethertype.
           touched 1.3.6.1.4.1.2950.9
This trap is generated when the IDENTIFY button is pressed. The agent throttles the generation of consecutive touched traps so that there is at least a two second gap between them.