SUPERMICRO-HEALTH-MIB: View SNMP OID List / Download MIB
VENDOR: SUPER MICRO COMPUTER INC.
Home | MIB: SUPERMICRO-HEALTH-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
smHealthMIB | 1.3.6.1.4.1.10876.2.1 |
MIB module for monitoring health information |
||
smHealthObjects | 1.3.6.1.4.1.10876.2.1.1 | |||
smHealthMonitorTable | 1.3.6.1.4.1.10876.2.1.1.1 | no-access |
A table of health monitoring entries. |
|
1.3.6.1.4.1.10876.2.1.1.1.1 | no-access |
An entry in the health monitoring table. Entries cannot be created or deleted via SNMP operations. |
||
smHealthMonitorIndex | 1.3.6.1.4.1.10876.2.1.1.1.1.1 | integer32 | no-access |
The unique value which identifies this Monitor device. |
smHealthMonitorName | 1.3.6.1.4.1.10876.2.1.1.1.1.2 | displaystring | read-only |
A textual full name assigned to the Monitor device. This object is suitable for output to a human operator. |
smHealthMonitorType | 1.3.6.1.4.1.10876.2.1.1.1.1.3 | smhealthinfotypes | read-only |
Identifies this Monitor device type. |
smHealthMonitorReading | 1.3.6.1.4.1.10876.2.1.1.1.1.4 | integer32 | read-only |
Indicates the value from the Monitor device that are currently in use on the managed device. FAN reading is in unit of RPM, Voltage reading is in unit of mV, Temperture reading is in unit of degree C |
smHealthMonitorHighLimit | 1.3.6.1.4.1.10876.2.1.1.1.1.5 | integer32 | read-write |
Indicates the value for the High limitation for the Monitor device that are currently in use on the managed device. Apply to Temperature and Voltage deivces only. Voltage limit is in unit of mV, Temperture limit is in unit of degree C |
smHealthMonitorLowLimit | 1.3.6.1.4.1.10876.2.1.1.1.1.6 | integer32 | read-write |
Indicates the value for the Low limitation for the Monitor device that are currently in use on the managed device. FAN limit is in unit of RPM, Voltage limit is in unit of mV, Temperture limit is in unit of degree C |
smHealthMonitorMaxReading | 1.3.6.1.4.1.10876.2.1.1.1.1.7 | integer32 | read-only |
Indicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device. FAN reading is in unit of RPM, Voltage reading is in unit of mV, Temperture reading is in unit of degree C |
smHealthMonitorMinReading | 1.3.6.1.4.1.10876.2.1.1.1.1.8 | integer32 | read-only |
Indicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device. FAN reading is in unit of RPM, Voltage reading is in unit of mV, Temperture reading is in unit of degree C |
smHealthMonitorDivisor | 1.3.6.1.4.1.10876.2.1.1.1.1.9 | integer32 | read-write |
Indicates the value for the Divisor for the Fan device that are currently in use on the managed device. Apply to Fan devices only. |
smHealthMonitorMonitor | 1.3.6.1.4.1.10876.2.1.1.1.1.10 | truthvalue | read-write |
Indicates the monitoring status for the Fan device that are currently in use on the managed device. 1 = monitor, 2=do not monitor |
smHealthNotifications | 1.3.6.1.4.1.10876.2.1.2 | |||
smHealthConformance | 1.3.6.1.4.1.10876.2.1.3 | |||
smHealthCompliances | 1.3.6.1.4.1.10876.2.1.3.1 | |||
smHealthCompliance | 1.3.6.1.4.1.10876.2.1.3.1.1 |
The compliance statement for entities which implement the Supermicro Health Monitoring MIB |
||
smHealthGroups | 1.3.6.1.4.1.10876.2.1.3.2 | |||
smHealthMonitorGroup | 1.3.6.1.4.1.10876.2.1.3.2.1 |
A collection of objects providing Monitor devices. |