SS7I-MIB: View SNMP OID List / Download MIB

VENDOR: UTSTARCOM INCORPORATED


 Home MIB: SS7I-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 usr 1.3.6.1.4.1.429
         nas 1.3.6.1.4.1.429.1
             ss7i 1.3.6.1.4.1.429.1.35
                   ss7iCfg 1.3.6.1.4.1.429.1.35.1
                       ss7iCfgTable 1.3.6.1.4.1.429.1.35.1.1 no-access
The Configuration Table contains an entry for each of the manageable HiPer SS7i cards in the chassis. It contains objects that reflect the current configuration of parameters that affect the operation of all the entities that reside on the given card.
                           ss7iCfgEntry 1.3.6.1.4.1.429.1.35.1.1.1 no-access
There is one Configuration Table entry per HiPer SS7i Card in the chassis.
                               ss7iCfgIndex 1.3.6.1.4.1.429.1.35.1.1.1.1 integer read-only
A unique value for each HiPer SS7i card in the chassis. The value of ss7iCfgIndex matches the value of the index for the corresponding HiPer SS7i card entity in the entity table of the chassis MIB.
                               ss7iCfgIpAddr 1.3.6.1.4.1.429.1.35.1.1.1.2 ipaddress read-write
The IP address on interface 0 of the HiPer SS7i.
                               ss7iCfgNetmask 1.3.6.1.4.1.429.1.35.1.1.1.3 ipaddress read-write
The netmask on interface 0 of the HiPer SS7i.
                               ss7iCfgDfltGwIpAddr 1.3.6.1.4.1.429.1.35.1.1.1.4 ipaddress read-write
The IP address of the default IP routing gateway.
                               ss7iCfgProtocol 1.3.6.1.4.1.429.1.35.1.1.1.5 integer read-write
The external signaling protocol running over the TCP/IP connection with the external signaling gateway. Default = hss7iSlapV2(1). Enumeration: 'slapV2': 1.
                               ss7iCfgGwConnStartMethod 1.3.6.1.4.1.429.1.35.1.1.1.6 integer read-write
The method used by the HiPer SS7i to bring up the TCP/IP connection to the external signaling gateway at boot time. Enumeration: 'lsManual': 2, 'lsAuto': 1.
                               ss7iCfgGwIpAddr 1.3.6.1.4.1.429.1.35.1.1.1.7 ipaddress read-write
The primary external SS7 gateway IP address. Valid for SLAP only.
                               ss7iCfgGwPort 1.3.6.1.4.1.429.1.35.1.1.1.8 integer read-write
The primary external SS7 gateway port number. Valid for SLAP only.
                               ss7iCfgSecGwIpAddr 1.3.6.1.4.1.429.1.35.1.1.1.9 ipaddress read-write
The secondary external SS7 gateway IP address. Valid for SLAP only.
                               ss7iCfgSecGwPort 1.3.6.1.4.1.429.1.35.1.1.1.10 integer read-write
The secondary external SS7 gateway port number. Valid for SLAP only.
                               ss7iCfgHrtbtTimerNearEnd 1.3.6.1.4.1.429.1.35.1.1.1.11 integer read-write
The HiPer SS7i heartbeat timer. Upon expiration, the HiPer SS7i will send a heartbeat message to the external SS7 gateway. The time should be less than what the gateway expects. Valid for SLAP only. Default = 15000 msec.
                               ss7iCfgHrtbtTimerFarEnd 1.3.6.1.4.1.429.1.35.1.1.1.12 integer read-write
The external SS7 gateway heartbeat timer. Upon expiration it causes the HiPer SS7i to commence the connection re-establishment procedure to the external SS7 gateway. The time should be longer than what the external SS7 gateway is set to. Valid for SLAP only. Default = 15000 msec.
                               ss7iCfgChassisId 1.3.6.1.4.1.429.1.35.1.1.1.13 octet string read-write
This uniquely identifies logical Chassis under the control of the HiPer SS7I, valid for SLAP only. The OCTET STRING format must be FF FF FF FF .
                               ss7iCfgGwConnRetryCnt 1.3.6.1.4.1.429.1.35.1.1.1.14 integer read-write
The number of times the HiPer SS7i will attempt to re-establish the TCP/IP connection to the external SS7 gateway after the initial failure was detected. Valid for SLAP only. Default = 3.
                               ss7iCfgGwConnRetryIntvl 1.3.6.1.4.1.429.1.35.1.1.1.15 integer read-write
The time interval between attempts of the HiPer SS7i to re-establish the TCP/IP connection to the external SS7 gateway. Valid for SLAP only. Default = 2 sec.
                               ss7iCfgGwMssdHrtbtThrsh 1.3.6.1.4.1.429.1.35.1.1.1.16 integer read-write
The number of external SS7 gateway heartbeat timeouts allowed before the connection to the gateway is considered lost. A setting of 0 means no attempt will be made to re-establish the connection. Default = 1.
                   ss7iCmd 1.3.6.1.4.1.429.1.35.2
                       ss7iCmdTable 1.3.6.1.4.1.429.1.35.2.1 no-access
The Command table contains an entry for each of the manageable HiPer SS7i cards in the chassis. It provides a means through which to take specific actions on them.
                           ss7iCmdEntry 1.3.6.1.4.1.429.1.35.2.1.1 no-access
There is one Command Table entry per HiPer SS7i card in the chassis.
                               ss7iCmdIndex 1.3.6.1.4.1.429.1.35.2.1.1.1 integer read-only
A unique value for each HiPer SS7i card in the chassis. The value of this object matches the value of the index of the corresponding HiPer SS7i card's entry in the entity table of the chassis MIB.
                               ss7iCmdMgtStationId 1.3.6.1.4.1.429.1.35.2.1.1.2 octet string read-write
This object is a generic read-write variable that a Management Station (MS) can use to guarantee that the results from a given command are the results of a command issued by that specific MS. Each MS must SET a unique value to this object when doing commands and GET the value of this object together with ss7iCmdReqId and ss7iCmdResult to detect interference from other MSs.
                               ss7iCmdReqId 1.3.6.1.4.1.429.1.35.2.1.1.3 integer read-only
This object contains the value of the request-id field in the SNMP PDU which invoked the current or most recent command or test on this HiPer SS7i card. If the request-id is unknown or undefined, this object contains the value zero.
                               ss7iCmdFunction 1.3.6.1.4.1.429.1.35.2.1.1.4 integer read-write
This object contains a value which describes the command which is being invoked. Enumeration: 'saveToNVRAM': 2, 'resetSS7Counters': 8, 'restoreFromNVRAM': 3, 'stopPbusConnToAll': 11, 'startSS7GwConn': 6, 'noCommand': 1, 'shutDownSS7GwConn': 7, 'softwareReset': 5, 'startPbusConnToAll': 10, 'restoreFromDefault': 4, 'resetPbusCounters': 9.
                               ss7iCmdForce 1.3.6.1.4.1.429.1.35.2.1.1.5 integer read-write
In some cases, the HiPer SS7i card may be in a state such that certain commands could adversely affect connections. In such cases, a command request with this object not present or set to noForce will result in a warning. If the operator elects to ignore such warnings, this object can be set to force in a subsequent issue of the command to cause the command to be carried out regardless of its potentially hazzardous effects. Enumeration: 'noForce': 2, 'force': 1.
                               ss7iCmdParam 1.3.6.1.4.1.429.1.35.2.1.1.6 octet string read-write
This object contains parameters that are specific to the particular command being issued. In some cases, there will be no aditional parameters required.
                               ss7iCmdResult 1.3.6.1.4.1.429.1.35.2.1.1.7 integer read-only
This object contains the result of the most recently requested command or test, or the value none(1) if no commands have been requested since the last reset. Enumeration: 'none': 1, 'success': 2, 'failed': 7, 'unAbleToRun': 5, 'aborted': 6, 'inProgress': 3, 'notSupported': 4.
                               ss7iCmdCode 1.3.6.1.4.1.429.1.35.2.1.1.8 integer read-only
The value of this object upon command completion indicates a further description of what went wrong if the command was unsuccessful. In the case of tests, a bit mapped result of each of the sub-tests performed can be found in the status table. Enumeration: 'pendingSoftwareDownload': 73, 'unsupportedCommand': 20, 'deviceDisabled': 22, 'unrecognizedCommand': 6, 'userInterfaceActive': 58, 'noError': 1, 'unable': 2, 'slotEmpty': 8, 'testFailed': 25, 'noResponse': 12.
                   ss7iTrap 1.3.6.1.4.1.429.1.35.3
                       ss7iTrapTable 1.3.6.1.4.1.429.1.35.3.1 no-access
Table containing objects to enable traps on the HiPer SS7i cards in the chassis.
                           ss7iTrapEntry 1.3.6.1.4.1.429.1.35.3.1.1 no-access
There is one entry for each HiPer SS7i card in the chassis.
                               ss7iTrapIndex 1.3.6.1.4.1.429.1.35.3.1.1.1 integer read-only
A unique index identifying the HiPer SS7i card to which the trap enable objects pertain.
                               ss7iTrapPbusLinkUp 1.3.6.1.4.1.429.1.35.3.1.1.2 integer read-write
Enables reporting of a trap and/or log message when the ENFAS packet bus signaling link to the HiPer Dsp comes up. Default = disableAll(2). Enumeration: 'enableTrap': 1, 'enableAll': 4, 'enableLog': 3, 'disableAll': 2.
                               ss7iTrapPbusLinkDown 1.3.6.1.4.1.429.1.35.3.1.1.3 integer read-write
Enables reporting of a trap and/or log message when the ENFAS packet bus signaling link to the HiPer Dsp goes down. Default = disableAll(2). Enumeration: 'enableTrap': 1, 'enableAll': 4, 'enableLog': 3, 'disableAll': 2.
                               ss7iTrapGwConnUp 1.3.6.1.4.1.429.1.35.3.1.1.4 integer read-write
Enables reporting of a trap and/or log message when the TCP/IP signaling connection to the SS7 (or media) gateway comes up. Default = disableAll(2). Enumeration: 'enableTrap': 1, 'enableAll': 4, 'enableLog': 3, 'disableAll': 2.
                               ss7iTrapGwConnDown 1.3.6.1.4.1.429.1.35.3.1.1.5 integer read-write
Enables reporting of a trap and/or log message when the TCP/IP signaling connection to the SS7 (or media) gateway goes down. Default = disableAll(2). Enumeration: 'enableTrap': 1, 'enableAll': 4, 'enableLog': 3, 'disableAll': 2.
                   ss7iStat 1.3.6.1.4.1.429.1.35.4
                       ss7iStatTable 1.3.6.1.4.1.429.1.35.4.1 no-access
The Statistics table contains an entry for each of the manageable HiPer SS7i cards in the chassis. It contains objects that reflect the current status of the card.
                           ss7iStatEntry 1.3.6.1.4.1.429.1.35.4.1.1 no-access
There is one Statistics table entry for each HiPer SS7i card in the chassis.
                               ss7iStatIndex 1.3.6.1.4.1.429.1.35.4.1.1.1 integer read-only
A unique value for each HiPer SS7i card in the chassis. The value of ss7iStatIndex matches the value of the index for the corresponding Hiper SS7i card entity in the entity table of the chassis MIB.
                               ss7iStatGwConnStatus 1.3.6.1.4.1.429.1.35.4.1.1.2 integer read-only
Status of the TCP/IP connection with the external signaling gateway. Valid for SLAP only. Enumeration: 'down': 2, 'up': 1.
                               ss7iStatGwNumMsgsRcvd 1.3.6.1.4.1.429.1.35.4.1.1.3 counter read-only
The number of messages received from the external SS7 gateway or the Media Gateway Controller.
                               ss7iStatGwNumBytesRcvd 1.3.6.1.4.1.429.1.35.4.1.1.4 counter read-only
The number of bytes received from the external SS7 gateway or the Media Gateway Controller.
                               ss7iStatGwNumMsgsSent 1.3.6.1.4.1.429.1.35.4.1.1.5 counter read-only
The number of messages sent to the external SS7 gateway or the Media Gateway Controller.
                               ss7iStatGwNumBytesSent 1.3.6.1.4.1.429.1.35.4.1.1.6 counter read-only
The number of bytes sent to the external SS7 gateway or the Media Gateway Controller.
                               ss7iStatGwMssdHrtbtCnt 1.3.6.1.4.1.429.1.35.4.1.1.7 counter read-only
The accumulated number of missed heartbeat messages expected to arrive from the external SS7 gateway.
                               ss7iStatGwLinkLostCnt 1.3.6.1.4.1.429.1.35.4.1.1.8 counter read-only
The accumulated number of times the physical Ethernet connection is unplugged or severed.
                               ss7iStatGwLinkErrCnt 1.3.6.1.4.1.429.1.35.4.1.1.9 counter read-only
The accumulated number of errors encountered sending to or receiving from the external SS7 gateway when the TCP/IP connection is believed to be healthy.
                               ss7iStatGwLinkDownCause 1.3.6.1.4.1.429.1.35.4.1.1.10 integer read-only
The reason the signaling connection to the external SS7 gateway went down. Enumeration: 'heartbeatTimeout': 2, 'none': 1, 'socketSndRcvError': 3, 'physicalLinkSevered': 4.
                   ss7iHdm 1.3.6.1.4.1.429.1.35.5
                       ss7iHdmTable 1.3.6.1.4.1.429.1.35.5.1 no-access
The ss7iHdm table contains objects for all of the HiPer Dsp cards in the chassis.
                           ss7iHdmEntry 1.3.6.1.4.1.429.1.35.5.1.1 no-access
There is one entry for each HiPer Dsp Card in the chassis.
                               ss7iHdmIndex 1.3.6.1.4.1.429.1.35.5.1.1.1 integer read-only
A unique value for each HiPer SS7i card in the chassis. The value of ss7iHdmIndex matches the value of the index for the corresponding HiPer SS7i card entity in the entity table of the chassis MIB.
                               ss7iHdmIndex2 1.3.6.1.4.1.429.1.35.5.1.1.2 integer read-only
The secondary index into the ss7iHdm table. There is one entry for each Hiper Dsp in the chassis. The value of the index is equal to the chassis slot number of a HiPer Dsp card.
                               ss7iHdmConnState 1.3.6.1.4.1.429.1.35.5.1.1.3 integer read-only
The state of the signaling packet bus connection to the HiPer Dsp. There is one connection from the HiPer SS7i card to each HiPer Dsp in the chassis. Enumeration: 'opened': 3, 'configuring': 4, 'opening': 2, 'loopback': 7, 'closed': 1, 'ready': 5, 'closing': 6.
                               ss7iHdmSndPktsOkCnt 1.3.6.1.4.1.429.1.35.5.1.1.4 counter read-only
The number of packets successfully transmitted over the signaling packet bus connection.
                               ss7iHdmSndPktsFailCnt 1.3.6.1.4.1.429.1.35.5.1.1.5 counter read-only
The number of packets failing to transmit over the signaling packet bus connection.
                               ss7iHdmRcvPktsOkCnt 1.3.6.1.4.1.429.1.35.5.1.1.6 counter read-only
The number of packets sucessfully received over the signaling packet bus connection.
                               ss7iHdmRcvPktsFailCnt 1.3.6.1.4.1.429.1.35.5.1.1.7 counter read-only
The number of signaling packet bus connection packets rejected by the HiPer SS7i message handler.
                               ss7iHdmLinkDownCause 1.3.6.1.4.1.429.1.35.5.1.1.8 integer read-only
The reason the packet bus ENFAS signaling link to the HiPer Dsp went down. Enumeration: 'pbusSndRcvError': 4, 'none': 1, 'missingHdm': 2, 'ss7GwLinkDown': 3.
                   ss7iSigPb 1.3.6.1.4.1.429.1.35.6
                       ss7iSigPbTable 1.3.6.1.4.1.429.1.35.6.1 no-access
The ss7iSigPb table contains objects for managing the signaling packet bus connections to all of the HiPer Dsp cards in the chassis.
                           ss7iSigPbEntry 1.3.6.1.4.1.429.1.35.6.1.1 no-access
There is one entry for each HiPer Dsp Card in the chassis.
                               ss7iSigPbIndex 1.3.6.1.4.1.429.1.35.6.1.1.1 integer read-only
A unique value for each HiPer SS7i card in the chassis. The value of ss7iSigPbIndex matches the value of the index for the corresponding HiPer SS7i card entity in the entity table of the chassis MIB.
                               ss7iSigPbIndex2 1.3.6.1.4.1.429.1.35.6.1.1.2 integer read-only
The secondary index into the ss7iSigPb table. There is one entry for each Hiper Dsp in the chassis. The value of the index is equal to the chassis slot number of a HiPer Dsp card.
                               ss7iSigPbConnection 1.3.6.1.4.1.429.1.35.6.1.1.3 integer read-write
The means to enable or disable a signaling packet bus connection between the HiPer SS7i and a Hiper Dsp. Default = disable(1). Enumeration: 'enable': 2, 'disable': 1.
                               ss7iSigPbLoopback 1.3.6.1.4.1.429.1.35.6.1.1.4 integer read-write
The means to enable or disable the loopback state on the signaling packet bus connection between the HiPer SS7i and a Hiper Dsp. Default = disable(1). Enumeration: 'enable': 2, 'disable': 1.