SONUS-SYSTEM-TIMING-MIB: View SNMP OID List / Download MIB

VENDOR: SONUS NETWORKS


 Home MIB: SONUS-SYSTEM-TIMING-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 sonusSystemTimingMIB 1.3.6.1.4.1.2879.2.1.3
The MIB Module for System Timing management.
     sonusSystemTimingMIBObjects 1.3.6.1.4.1.2879.2.1.3.1
         sonusStShelfAdmnTable 1.3.6.1.4.1.2879.2.1.3.1.1 no-access
             sonusStShelfAdmnEntry 1.3.6.1.4.1.2879.2.1.3.1.1.1 no-access
                 sonusStShelfAdmnShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.1.1.1 sonusshelfindex read-only
Identifies the target shelf within the node.
                 sonusStShelfAdmnFailoverGuardTime 1.3.6.1.4.1.2879.2.1.3.1.1.1.2 integer32 read-write
Indicates how long a timing source can be faulting before switchover to another source is initiated
                 sonusStShelfAdmnRecoveryGuardTime 1.3.6.1.4.1.2879.2.1.3.1.1.1.3 integer32 read-write
Indicates how long a timing source must be valid for, after it has faulted, before it will be considered valid again.
                 sonusStShelfAdmnTransmitRemoteAlarm 1.3.6.1.4.1.2879.2.1.3.1.1.1.4 integer read-write
Not Supported Enumeration: 'disabled': 1, 'enabled': 2.
                 sonusStShelfAdmnRevertRefSwitching 1.3.6.1.4.1.2879.2.1.3.1.1.1.5 integer read-write
If enabled, then a timing source which has failed, but then becomes valid again, will be reconsidered for use. If disabled, then once a timing source fails, it will never be automatically reconsidered for use. To use the source again requires manual user intervention. Enumeration: 'disabled': 1, 'enabled': 2.
                 sonusStShelfAdmnRevertMtaSwitching 1.3.6.1.4.1.2879.2.1.3.1.1.1.6 integer read-write
If enabled, then an MTA which is hot-inserted will automatically be brought on line and made available for use. If disabled, then an MTA which is hot-inserted will require manual user configuration before being available for use. Enumeration: 'disabled': 1, 'enabled': 2.
                 sonusStShelfAdmnRevertInsertDelay 1.3.6.1.4.1.2879.2.1.3.1.1.1.7 integer32 read-write
MTA warm-up period. When an MTA is hot-inserted, the card will be allowed to warm up and stabilize for this amount of time before being put back into service. This warm-up period is also used during cold start of a shelf.
                 sonusStShelfAdmnFreeRunAlarm 1.3.6.1.4.1.2879.2.1.3.1.1.1.8 integer read-write
Not Supported Enumeration: 'disabled': 1, 'enabled': 2.
                 sonusStShelfAdmnTimingSourceAction 1.3.6.1.4.1.2879.2.1.3.1.1.1.9 integer read-write
Resequence will cause the timing sequence list to be re-evaluated. This may cause the current active timing source to change. Enumeration: 'none': 1, 'resequence': 2.
                 sonusStShelfAdmnRowStatus 1.3.6.1.4.1.2879.2.1.3.1.1.1.10 rowstatus read-write
This object indicates the row status for this table.
                 sonusStShelfAdmnSourceReconfigAlg 1.3.6.1.4.1.2879.2.1.3.1.1.1.11 integer read-write
This object indicates which algorithm should be used to select timing sources for use as System Synchronized sources. Selecting Ordered_list causes sources to be selected for use in strict numerical order, as assigned by default or by the operator. Selecting SSM_Quality will cause sources to be selected based upon the quality level of the timing source, as indicated by the sources Synchronized Status Messages. Do not select SSM_Quality unless all configured timing sources support SSM's Enumeration: 'ordered-list': 1, 'ssm-quality': 2.
                 sonusStShelfAdmnMtaSourceAffinity 1.3.6.1.4.1.2879.2.1.3.1.1.1.12 integer read-write
This object works in conjunction with the Source Reconfiguration Algorithm object. If sticky is selected, System Timing Manager will exhaust oll timing sources on an MTA at all quality levels before selecting a timing source on the alternate MTA. If none is selected, timing sources will be chosen based on stratum quality only, reguardless of which MTA is providing the source. This object has no effect when the Source Reconfiguration Algorithm is set to Ordered_list. Enumeration: 'none': 1, 'sticky': 2.
         sonusStShelfStatTable 1.3.6.1.4.1.2879.2.1.3.1.2 no-access
             sonusStShelfStatEntry 1.3.6.1.4.1.2879.2.1.3.1.2.1 no-access
                 sonusStShelfStatShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.2.1.1 sonusshelfindex read-only
                 sonusStShelfStatActiveMtaSlot 1.3.6.1.4.1.2879.2.1.3.1.2.1.2 sonusmtaslotindex read-only
Identifies which MTA is providing the System Synchronized Timing signal.
                 sonusStShelfStatActiveSource 1.3.6.1.4.1.2879.2.1.3.1.2.1.3 sonustimingsource read-only
Identifies what timing source the active MTA is using to provide System Synchronized Timing.
         sonusStMtaAdmnTable 1.3.6.1.4.1.2879.2.1.3.1.3 no-access
             sonusStMtaAdmnEntry 1.3.6.1.4.1.2879.2.1.3.1.3.1 no-access
                 sonusStMtaAdmnShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.3.1.1 sonusshelfindex read-only
Identifies the target shelf within the node.
                 sonusStMtaAdmnMtaSlotIndex 1.3.6.1.4.1.2879.2.1.3.1.3.1.2 sonusmtaslotindex read-only
Identifies the target slot within the shelf.
                 sonusStMtaAdmnState 1.3.6.1.4.1.2879.2.1.3.1.3.1.3 sonusadminstate read-write
If enabled, the MTA can participate in system timing. If disabled, then it will be removed from service and not allowed to participate. All timing sequence entries bound to this node will be marked as out of service. In a non-redundant configuration the MTA admin state cannot be disabled.
                 sonusStMtaAdmnLineEncoding 1.3.6.1.4.1.2879.2.1.3.1.3.1.4 integer read-write
Select AMI or B8ZS line coding for BITS LIU. Select HDB3 for SETS LIU Enumeration: 'ami': 1, 'hdb3': 3, 'b8zs': 2.
                 sonusStMtaAdmnSsmChannelBit 1.3.6.1.4.1.2879.2.1.3.1.3.1.5 integer read-write
MTA 20, E1 support only. Identifies which of the additional spare bits, embedded within the framing pattern, contains the SSM channel Enumeration: 'sa8': 5, 'sa7': 4, 'sa6': 3, 'sa5': 2, 'sa4': 1.
                 sonusStMtaAdmnFramerMode 1.3.6.1.4.1.2879.2.1.3.1.3.1.6 integer read-write
Select ESF or D4/SF for BITS framer. ESF should be selected if B8ZS has been selected for the line encoding. D4/SF should be selected if AMI has been selected for the line encoding. Select MF or MF-CRC4 for SETS framer Enumeration: 'mf': 3, 'esf': 2, 'd4sf': 1, 'mf-crc4': 4.
                 sonusStMtaAdmnFramerTransmitYellowAlarm 1.3.6.1.4.1.2879.2.1.3.1.3.1.7 integer read-write
Not supported Enumeration: 'disabled': 1, 'enabled': 2.
                 sonusStMtaAdmnLiuTransmitAllOnes 1.3.6.1.4.1.2879.2.1.3.1.3.1.8 integer read-write
Not supported Enumeration: 'disabled': 1, 'enabled': 2.
                 sonusStMtaAdmnAction 1.3.6.1.4.1.2879.2.1.3.1.3.1.9 integer read-write
Selecting AVAILABLE will cause the MTA to be moved from the Out-Of-Service state to the Available-For-Use state. This command is necessary to manually make an MTA available for use after it has failed, and revertive MTA switching is not enabled. This may cause the current active timing source to change. Enumeration: 'available': 2, 'none': 1.
                 sonusStMtaAdmnRowStatus 1.3.6.1.4.1.2879.2.1.3.1.3.1.10 rowstatus read-write
This object indicates the row status for this table.
         sonusStMtaStatTable 1.3.6.1.4.1.2879.2.1.3.1.4 no-access
             sonusStMtaStatEntry 1.3.6.1.4.1.2879.2.1.3.1.4.1 no-access
                 sonusStMtaStatShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.4.1.1 sonusshelfindex read-only
                 sonusStMtaStatMtaSlotIndex 1.3.6.1.4.1.2879.2.1.3.1.4.1.2 sonusmtaslotindex read-only
                 sonusStMtaStatOperStat 1.3.6.1.4.1.2879.2.1.3.1.4.1.3 integer read-only
Indicates the operational status of the MTA Enumeration: 'outOfService': 5, 'available': 6, 'fault': 2, 'notPresent': 1, 'warmupDelay': 3, 'inService': 4.
                 sonusStMtaStatMtaHwDesc 1.3.6.1.4.1.2879.2.1.3.1.4.1.4 displaystring read-only
Description of the MTA hardware in the form of 'hwtype_hwRev'.
                 sonusStMtaStatMtaHwType 1.3.6.1.4.1.2879.2.1.3.1.4.1.5 hwtypeid read-only
Description of the MTA hardware Type only. Entry 5+6 obsolete entry 4.
                 sonusStMtaStatMtaHwTypeRev 1.3.6.1.4.1.2879.2.1.3.1.4.1.6 integer32 read-only
Description of the MTA hardware type revision. Entry 5+6 obsolete entry 4.
                 sonusStMtaStatMtaSerialNum 1.3.6.1.4.1.2879.2.1.3.1.4.1.7 displaystring read-only
Identifies the serial number of the server module. This is the serial number assigned to the mta module in manufacturing.
                 sonusStMtaStatMtaPartNum 1.3.6.1.4.1.2879.2.1.3.1.4.1.8 displaystring read-only
Identifies the part number of the server module. This is the part number assigned to the mta module in manufacturing.
         sonusStTimingSourceTable 1.3.6.1.4.1.2879.2.1.3.1.5 no-access
             sonusStTimingSourceEntry 1.3.6.1.4.1.2879.2.1.3.1.5.1 no-access
                 sonusStTimingSourceShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.5.1.1 sonusshelfindex read-write
                 sonusStTimingSourceMtaSlotIndex 1.3.6.1.4.1.2879.2.1.3.1.5.1.2 integer32 read-write
Indicates which MTA this timing node is bound to.
                 sonusStTimingSource 1.3.6.1.4.1.2879.2.1.3.1.5.1.3 sonustimingsource read-write
Indicates which physical timing source is bound to this node. External BITS sources are used by MTA 10's, in T1 based chassis'. External SETS sources are used by MTA 2X's, in E1 based chassis'. REFCLK's are based upon timing recovered from a CNS or PNS Server card. HOLDOVER mimics the last known good source before it failed. OSCILLATOR is used when no other valid sources exist on the currently active MTA.
                 sonusStTimingSourceState 1.3.6.1.4.1.2879.2.1.3.1.5.1.4 sonusadminstate read-write
If enabled, the source can participate in system timing. If disabled, then it will be removed from service and not be allowed to participate.
                 sonusStTimingSourceSequenceNum 1.3.6.1.4.1.2879.2.1.3.1.5.1.5 integer32 read-write
The timing sequence number is automatically generated
                 sonusStTimingSourceAction 1.3.6.1.4.1.2879.2.1.3.1.5.1.6 integer read-write
Selecting AVAILABLE will cause the timing source to be moved from the Out-Of-Service state to the Available-For-Use state. This command is necessary to manually make a source available for use after it has failed, and revertive source switching is not enabled. This may cause the current active timing source to change. Enumeration: 'available': 2, 'none': 1.
                 sonusStTimingSourceRowStatus 1.3.6.1.4.1.2879.2.1.3.1.5.1.7 rowstatus read-write
This object indicates the row status for this table.
         sonusStTimingSourceStatTable 1.3.6.1.4.1.2879.2.1.3.1.6 no-access
             sonusStTimingSourceStatEntry 1.3.6.1.4.1.2879.2.1.3.1.6.1 no-access
                 sonusStTimingSourceStatShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.6.1.1 sonusshelfindex read-only
Indicates shelf.
                 sonusStTimingSourceStatMtaSlotIndex 1.3.6.1.4.1.2879.2.1.3.1.6.1.2 sonusmtaslotindex read-only
Indicates which MTA this timing node is bound to.
                 sonusStTimingSourceStat 1.3.6.1.4.1.2879.2.1.3.1.6.1.3 sonustimingsource read-only
Indicates the physical timing source
                 sonusStTimingSourceStatState 1.3.6.1.4.1.2879.2.1.3.1.6.1.4 integer read-only
Indicates the current overall state of the timing source, including the hardware state, adminitrative mode and shelf configuration Enumeration: 'available': 1, 'outofservice': 4, 'faulting': 3, 'notpresent': 6, 'inservice': 2, 'cannotlocate': 5.
                 sonusStTimingSourceStatTraceability 1.3.6.1.4.1.2879.2.1.3.1.6.1.5 integer read-only
Indicates the Quality Level of the System Synchronized Timing Source Enumeration: 'qualityunknown': 12, 'reserved': 9, 'stratum4': 8, 'stratum1': 2, 'stratum2': 3, 'stratum3': 6, 'indeterminate': 11, 'synchronizedunknown': 1, 'dontUse': 10, 'stratumSonetMinimum': 7, 'g812local': 15, 'stratum3e': 5, 'g811': 13, 'stratumTNC': 4, 'g704rsvdql9': 22, 'g812transit': 14, 'g704rsvdql5': 19, 'g704rsvdql7': 21, 'g704rsvdql6': 20, 'g704rsvdql1': 17, 'g704rsvdql3': 18, 'sets': 16, 'g704rsvdql10': 23, 'g704rsvdql13': 25, 'g704rsvdql12': 24, 'g704rsvdql14': 26.
                 sonusStTimingSourceStatLineState 1.3.6.1.4.1.2879.2.1.3.1.6.1.6 integer read-only
Indicates the current physical status of the timing source Enumeration: 'valid': 1, 'notvalid': 2.
         sonusStChannelBindingTable 1.3.6.1.4.1.2879.2.1.3.1.7 no-access
This table describes how derived timing sources should be mapped to the MTA hardware
             sonusStChannelBindingEntry 1.3.6.1.4.1.2879.2.1.3.1.7.1 no-access
                 sonusStChannelBindingShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.7.1.1 sonusshelfindex read-only
                 sonusStChannelBindingSlotIndex 1.3.6.1.4.1.2879.2.1.3.1.7.1.2 sonusslotindex read-only
Server slot number to provide a recovered clock source. The same server can be configured to provide both possible recovered clocks as long as different channels(spans) are selected, and the REFCLK each is bound to differs
                 sonusStChannelBindingChannel 1.3.6.1.4.1.2879.2.1.3.1.7.1.3 integer32 read-only
T1/E1 span or OC12 port number to provide the recovered clock source. T1 span range is 1-12(CNS10), 1-28(CNS30), E1 span range is 1-8(CNS20), OC12 port number(PNS20) is 1 only.
                 sonusStChannelBindingRefClk 1.3.6.1.4.1.2879.2.1.3.1.7.1.4 integer read-only
Backplane signal the recovered clock source should be bound to. Each REFCLK must only be bound to a single Server slot/span. Enumeration: 'refClkA': 1, 'refClkB': 2.
                 sonusStChannelBindingRowStatus 1.3.6.1.4.1.2879.2.1.3.1.7.1.5 rowstatus read-write
This object indicates the row status for this table.
     sonusSystemTimingMIBNotifications 1.3.6.1.4.1.2879.2.1.3.2
         sonusSystemTimingMIBNotificationsPrefix 1.3.6.1.4.1.2879.2.1.3.2.0
             sonusSystemTimingActiveFailedNotification 1.3.6.1.4.1.2879.2.1.3.2.0.1
This trap indicates that the currently active System Timing clock source has failed.
             sonusSystemTimingActiveSwitchoverNotification 1.3.6.1.4.1.2879.2.1.3.2.0.2
This trap indicates that the active System Timing clock source has been switched to another source.
             sonusSystemTimingOscillatorActiveNotification 1.3.6.1.4.1.2879.2.1.3.2.0.3
This trap indicates that all external sources of System Timing have failed and that the current source of timing is the MTA's internal oscillator.
             sonusSystemTimingMTAFailedNotification 1.3.6.1.4.1.2879.2.1.3.2.0.4
This trap indicates that the MTA indicated has failed or been removed from the shelf.
             sonusSystemTimingMTAOperationalNotification 1.3.6.1.4.1.2879.2.1.3.2.0.6
This trap indicates that the specified MTA is now operational.
             sonusSystemTimingMTATotalFailureNotification 1.3.6.1.4.1.2879.2.1.3.2.0.7
This trap indicates that no MTA's are available for use to provide System Timing. They have either failed, been removed from service or been removed from the shelf. The shelf is no longer capable of being properly timed. Downstream Shelves or other equipment connected to this shelf's MITDC(Marlin Inter-chassis Timing Daisy Chain) may be affected.
         sonusSystemTimingMIBNotificationsObjects 1.3.6.1.4.1.2879.2.1.3.2.1
             sonusTimingSource 1.3.6.1.4.1.2879.2.1.3.2.1.1 sonustimingsource read-only
             sonusTimingSource2 1.3.6.1.4.1.2879.2.1.3.2.1.2 sonuseventstring read-only