Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 socomec 1.3.6.1.4.1.4555
           ups 1.3.6.1.4.1.4555.2
               pdu 1.3.6.1.4.1.4555.2.30
                     dpduIdent 1.3.6.1.4.1.4555.2.30.1
                         dpduIdentManufacturer 1.3.6.1.4.1.4555.2.30.1.1 displaystring read-only
The EnviroStation Vendor.
                         dpduIdentModel 1.3.6.1.4.1.4555.2.30.1.2 displaystring read-only
The PDU Model designation.
                         dpduIdentSerialNumber 1.3.6.1.4.1.4555.2.30.1.3 displaystring read-only
The PDU serial number
                         dpduIdentPDUFirmwareVersion 1.3.6.1.4.1.4555.2.30.1.4 displaystring read-only
The PDU firmware version
                         dpduIdentAgentSoftwareVersion 1.3.6.1.4.1.4555.2.30.1.5 displaystring read-only
The PDU NMC software version
                         dpduIdentName 1.3.6.1.4.1.4555.2.30.1.6 displaystring read-write
A string identifying the PDU. This object should be set by the administrator.
                         dpduAttachedDevices 1.3.6.1.4.1.4555.2.30.1.7 displaystring read-write
A string identifying the devices attached to the output(s) of the PDU. This object should be set by the administrator.
                     dpduOutput 1.3.6.1.4.1.4555.2.30.2
                         dpduOutputFrequency 1.3.6.1.4.1.4555.2.30.2.1 integer read-only
The present output frequency in 1/10 Hz.
                         dpduOutputVoltage1 1.3.6.1.4.1.4555.2.30.2.2 integer read-only
The Output line 1 voltage of the PDU system in 1/10 V.
                         dpduOutputCurrent1 1.3.6.1.4.1.4555.2.30.2.3 integer read-only
The Output line 1 current of the PDU system in 1/10 A.
                         dpduOutputVoltage2 1.3.6.1.4.1.4555.2.30.2.4 integer read-only
The Output line 2 voltage of the PDU system in 1/10 V.
                         dpduOutputCurrent2 1.3.6.1.4.1.4555.2.30.2.5 integer read-only
The Output line 2 current of the PDU system in 1/10 A.
                         dpduOutputVoltage3 1.3.6.1.4.1.4555.2.30.2.6 integer read-only
The Output line 3 voltage of the PDU system in 1/10 V.
                         dpduOutputCurrent3 1.3.6.1.4.1.4555.2.30.2.7 integer read-only
The Output line 3 current of the PDU system in 1/10 A.
                     dpduAlarm 1.3.6.1.4.1.4555.2.30.3
                         dpduAlarmDisconnect 1.3.6.1.4.1.4555.2.30.3.1 integer read-only
Does the PDU disconnect? Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL1LoadMajor 1.3.6.1.4.1.4555.2.30.3.2 integer read-only
L1 load major alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL1LoadMinor 1.3.6.1.4.1.4555.2.30.3.3 integer read-only
L1 load minor alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL1OutVoltMajor 1.3.6.1.4.1.4555.2.30.3.4 integer read-only
L1 output votage major alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL1OutVoltMinor 1.3.6.1.4.1.4555.2.30.3.5 integer read-only
L1 output voltage minor alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL2LoadMajor 1.3.6.1.4.1.4555.2.30.3.6 integer read-only
L2 load major alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL2LoadMinor 1.3.6.1.4.1.4555.2.30.3.7 integer read-only
L2 load minor alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL2OutVoltMajor 1.3.6.1.4.1.4555.2.30.3.8 integer read-only
L2 output votage major alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL2OutVoltMinor 1.3.6.1.4.1.4555.2.30.3.9 integer read-only
L2 output voltage minor alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL3LoadMajor 1.3.6.1.4.1.4555.2.30.3.10 integer read-only
L3 load major alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL3LoadMinor 1.3.6.1.4.1.4555.2.30.3.11 integer read-only
L3 load minor alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL3OutVoltMajor 1.3.6.1.4.1.4555.2.30.3.12 integer read-only
L3 output votage major alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL3OutVoltMinor 1.3.6.1.4.1.4555.2.30.3.13 integer read-only
L3 output voltage minor alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL12LoadMajor 1.3.6.1.4.1.4555.2.30.3.14 integer read-only
L1, L2 load major alarm Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmL12LoadMinor 1.3.6.1.4.1.4555.2.30.3.15 integer read-only
L1, L2 load minor alarm Enumeration: 'on': 1, 'off': 0.
                     dpduEnvironment 1.3.6.1.4.1.4555.2.30.4
                         dpduEnvTemperature 1.3.6.1.4.1.4555.2.30.4.1 integer read-only
The ambient environmental temperature.
                         dpduEnvHumidity 1.3.6.1.4.1.4555.2.30.4.2 integer read-only
The environmental humidity.
                         dpduEnvSetTemperatureWarnLimit 1.3.6.1.4.1.4555.2.30.4.3 integer read-write
Alarm dpduEnvOverWarnTemperature on when the environmental temperature over the value.
                         dpduEnvSetTemperatureAlarmLimit 1.3.6.1.4.1.4555.2.30.4.4 integer read-write
Alarm dpduEnvOverAlarmTemperature on when the environmental temperature over the value.
                         dpduEnvSetHumidityWarnLimit 1.3.6.1.4.1.4555.2.30.4.5 integer read-write
Alarm dpduEnvOverWarnHumidity on when the environmental humidity over the value.
                         dpduEnvSetHumidityAlarmLimit 1.3.6.1.4.1.4555.2.30.4.6 integer read-write
Alarm dpduEnvOverAlarmHumidity on when the environmental humidity over the value.
                         dpduEnvSetEnvRelay1 1.3.6.1.4.1.4555.2.30.4.7 integer read-write
Enumeration: 'normalClose': 1, 'normalOpen': 0.
                         dpduEnvSetEnvRelay2 1.3.6.1.4.1.4555.2.30.4.8 integer read-write
Enumeration: 'normalClose': 1, 'normalOpen': 0.
                         dpduEnvSetEnvRelay3 1.3.6.1.4.1.4555.2.30.4.9 integer read-write
Enumeration: 'normalClose': 1, 'normalOpen': 0.
                         dpduEnvSetEnvRelay4 1.3.6.1.4.1.4555.2.30.4.10 integer read-write
Enumeration: 'normalClose': 1, 'normalOpen': 0.
                         dpduWarnOverEnvTemperature 1.3.6.1.4.1.4555.2.30.4.11 integer read-only
Does the environment over warning temperature? Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmOverEnvTemperature 1.3.6.1.4.1.4555.2.30.4.12 integer read-only
Does the environment over alarm temperature? Enumeration: 'on': 1, 'off': 0.
                         dpduWarnmOverEnvHumidity 1.3.6.1.4.1.4555.2.30.4.13 integer read-only
Does the environment over warn humidity? Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmOverEnvHumidity 1.3.6.1.4.1.4555.2.30.4.14 integer read-only
Does the environment over alarm humidity? Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmEnvRelay1 1.3.6.1.4.1.4555.2.30.4.15 integer read-only
The alarm status of relay1. Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmEnvRelay2 1.3.6.1.4.1.4555.2.30.4.16 integer read-only
The alarm status of relay2. Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmEnvRelay3 1.3.6.1.4.1.4555.2.30.4.17 integer read-only
The alarm status of relay3. Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmEnvRelay4 1.3.6.1.4.1.4555.2.30.4.18 integer read-only
The alarm status of relay4. Enumeration: 'on': 1, 'off': 0.
                         dpduAlarmEnvDisconnect 1.3.6.1.4.1.4555.2.30.4.19 integer read-only
To indicate the communication status of EnviroProbe. Enumeration: 'yes': 1, 'no': 0.
                     dpduTraps 1.3.6.1.4.1.4555.2.30.20
                             dpduCommunicationLost 1.3.6.1.4.1.4555.2.30.200.1
Communication with the PDU failed.
                             dpduCommunicationEstablished 1.3.6.1.4.1.4555.2.30.200.2
Communication with the PDU reestablished.
                             dpduL1LoadMajorAlarm 1.3.6.1.4.1.4555.2.30.200.3
L1 load major alarm.
                             dpduL1LoadMajorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.4
Recover from L1 load major alarm.
                             dpduL1LoadMinorAlarm 1.3.6.1.4.1.4555.2.30.200.5
L1 load minor alarm.
                             dpduL1LoadMinorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.6
Recover from L1 load minor alarm.
                             dpduL1OutVoltMajorAlarm 1.3.6.1.4.1.4555.2.30.200.7
L1 output voltage major alarm.
                             dpduL1OutVoltMajorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.8
Recover from L1 output voltage major alarm.
                             dpduL1OutVoltMinorAlarm 1.3.6.1.4.1.4555.2.30.200.9
L1 output voltage minor alarm.
                             dpduL1OutVoltMinorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.10
Recover from L1 output voltage minor alarm.
                             dpduL2LoadMajorAlarm 1.3.6.1.4.1.4555.2.30.200.11
L2 load major alarm.
                             dpduL2LoadMajorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.12
Recover from L2 load major alarm.
                             dpduL2LoadMinorAlarm 1.3.6.1.4.1.4555.2.30.200.13
L2 load minor alarm.
                             dpduL2LoadMinorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.14
Recover from L2 load minor alarm.
                             dpduL2OutVoltMajorAlarm 1.3.6.1.4.1.4555.2.30.200.15
L2 output voltage major alarm.
                             dpduL2OutVoltMajorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.16
Recover from L2 output voltage major alarm.
                             dpduL2OutVoltMinorAlarm 1.3.6.1.4.1.4555.2.30.200.17
L2 output voltage minor alarm.
                             dpduL2OutVoltMinorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.18
Recover from L2 output voltage minor alarm.
                             dpduL3LoadMajorAlarm 1.3.6.1.4.1.4555.2.30.200.19
L3 load major alarm.
                             dpduL3LoadMajorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.20
Recover from L3 load major alarm.
                             dpduL3LoadMinorAlarm 1.3.6.1.4.1.4555.2.30.200.21
L3 load minor alarm.
                             dpduL3LoadMinorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.22
Recover from L3 load minor alarm.
                             dpduL3OutVoltMajorAlarm 1.3.6.1.4.1.4555.2.30.200.23
L3 output voltage major alarm.
                             dpduL3OutVoltMajorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.24
Recover from L3 output voltage major alarm.
                             dpduL3OutVoltMinorAlarm 1.3.6.1.4.1.4555.2.30.200.25
L3 output voltage minor alarm.
                             dpduL3OutVoltMinorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.26
Recover from L3 output voltage minor alarm.
                             dpduL12LoadMajorAlarm 1.3.6.1.4.1.4555.2.30.200.27
L1 L2 load major alarm.
                             dpduL12LoadMajorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.28
Recover from L1 L2 load major alarm.
                             dpduL12LoadMinorAlarm 1.3.6.1.4.1.4555.2.30.200.29
L1 L2 load minor alarm.
                             dpduL12LoadMinorAlarmRecover 1.3.6.1.4.1.4555.2.30.200.30
Recover from L1 L2 load minor alarm.
                             dpduEnvCommunicationLost 1.3.6.1.4.1.4555.2.30.200.31
Communication with the environmental sensor failed.
                             dpduEnvCommunicationEstablished 1.3.6.1.4.1.4555.2.30.200.32
Communication with the environmental sensor reestablished.
                             dpduEnvOverWarnTemperature 1.3.6.1.4.1.4555.2.30.200.33
The environment over warning temperature.
                             dpduNoLongerEnvOverWarnTemperature 1.3.6.1.4.1.4555.2.30.200.34
The environment recovered from over warning temperature.
                             dpduEnvOverWarnHumidity 1.3.6.1.4.1.4555.2.30.200.35
The environment over warning humidity.
                             dpduNoLongerEnvOverWarnHumidity 1.3.6.1.4.1.4555.2.30.200.36
The environment recovered from over warning humidity.
                             dpduEnvOverAlarmTemperature 1.3.6.1.4.1.4555.2.30.200.37
The environment over alarm temperature.
                             dpduNoLongerEnvOverAlarmTemperature 1.3.6.1.4.1.4555.2.30.200.38
The environment recovered from over alarm temperature.
                             dpduEnvOverAlarmHumidity 1.3.6.1.4.1.4555.2.30.200.39
The environment over alarm humidity.
                             dpduNoLongerEnvOverAlarmHumidity 1.3.6.1.4.1.4555.2.30.200.40
The environment recovered from over alarm humidity.
                             dpduEnvRelay1Alarm 1.3.6.1.4.1.4555.2.30.200.41
The environment relay1 is not in normal state.
                             dpduEnvRelay1Normal 1.3.6.1.4.1.4555.2.30.200.42
The environment relay1 is in normal state.
                             dpduEnvRelay2Alarm 1.3.6.1.4.1.4555.2.30.200.43
The environment relay2 is not in normal state.
                             dpduEnvRelay2Normal 1.3.6.1.4.1.4555.2.30.200.44
The environment relay2 is in normal state.
                             dpduEnvRelay3Alarm 1.3.6.1.4.1.4555.2.30.200.45
The environment relay3 is not in normal state.
                             dpduEnvRelay3Normal 1.3.6.1.4.1.4555.2.30.200.46
The environment relay3 is in normal state.
                             dpduEnvRelay4Alarm 1.3.6.1.4.1.4555.2.30.200.47
The environment relay4 is not in normal state.
                             dpduEnvRelay4Normal 1.3.6.1.4.1.4555.2.30.200.48
The environment relay4 is in normal state.