Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 sni 1.3.6.1.4.1.231
         sniProductMibs 1.3.6.1.4.1.231.2
             sniExtensions 1.3.6.1.4.1.231.2.10
                   sniServerMgmt 1.3.6.1.4.1.231.2.10.2
                       sniInventory 1.3.6.1.4.1.231.2.10.2.1
                       sniCommon 1.3.6.1.4.1.231.2.10.2.2
                           sniBios 1.3.6.1.4.1.231.2.10.2.2.1
                           sniEisa 1.3.6.1.4.1.231.2.10.2.2.2
                           sniHd 1.3.6.1.4.1.231.2.10.2.2.3
                           sniBus 1.3.6.1.4.1.231.2.10.2.2.4
                           sniServerControl 1.3.6.1.4.1.231.2.10.2.2.5
                               agentInfo 1.3.6.1.4.1.231.2.10.2.2.5.1
                                   agentId 1.3.6.1.4.1.231.2.10.2.2.5.1.1 displaystring read-only
Agent identification string
                                   agentCompany 1.3.6.1.4.1.231.2.10.2.2.5.1.2 displaystring read-only
Agent's company name
                                   agentVersionString 1.3.6.1.4.1.231.2.10.2.2.5.1.3 displaystring read-only
Agent's version string . (i.e. 1.05)
                                   agentBuild 1.3.6.1.4.1.231.2.10.2.2.5.1.4 displaystring read-only
Compilation time and date of agent program
                                   agentVersionMajor 1.3.6.1.4.1.231.2.10.2.2.5.1.5 integer read-only
Agent's major version (numerical)
                                   agentVersionMinor 1.3.6.1.4.1.231.2.10.2.2.5.1.6 integer read-only
Agent's minor version (numerical)
                                   agentWriteAllowed 1.3.6.1.4.1.231.2.10.2.2.5.1.7 integer read-only
Defines whether writable objects can be written (except shutdown/power-off operations) Enumeration: 'unknown': 1, 'write-not-allowed': 2, 'write-allowed': 3.
                                   agentShutdownAllowed 1.3.6.1.4.1.231.2.10.2.2.5.1.8 integer read-only
Defines whether shutdown/power-off objects can be written Enumeration: 'unknown': 1, 'shutdown-not-allowed': 2, 'shutdown-allowed': 3.
                               environment 1.3.6.1.4.1.231.2.10.2.2.5.2
                                   temperatureSensorsTable 1.3.6.1.4.1.231.2.10.2.2.5.2.1 no-access
Table with data of all configured temperature sensors
                                       temperatureSensors 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1 no-access
                                           tempCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.1 integer read-only
ID of the cabinet the temperature sensor is in (index, 0 based)
                                           tempSensorNumber 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.2 integer read-only
Number of the sensor in this cabinet (index, 0 based)
                                           tempSensorStatus 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3 integer read-only
Status of this temperature sensor (OK, critical or shutdown temperature reached...). The cold and the damage temperature status levels are no longer supported (values 6, 8, 9, 10). Status not-available(99) can be a sensor of a cpu that is not installed. Status sensor-disabled(2) is currently not used. Enumeration: 'sensor-fail': 4, 'not-available': 99, 'critical-temp-warm': 7, 'ok': 3, 'warning-temp-cold': 6, 'unknown': 1, 'sensor-disabled': 2, 'damage-temp-cold': 10, 'warning-temp-warm': 5, 'damage-temp-warm': 9, 'critical-temp-cold': 8.
                                           tempSensorPurpose 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.4 integer read-only
Purpose of this temperature sensor (CPU, ambient, housing...). Purposes disable(2) and not-available(6) are no longer used. Enumeration: 'not-available': 6, 'unknown': 1, 'housing': 5, 'io-board': 7, 'cp': 3, 'disable': 2, 'ambient': 4, 'power-backplane': 8.
                                           tempLowerWarningLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.5 integer read-only
Object made obsolete - no longer supported
                                           tempUpperWarningLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.6 integer read-only
System sends a temperature warning when temperature rises ABOVE this level (degrees Celsius)
                                           tempLowerCriticalLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.7 integer read-only
Object made obsolete - no longer supported
                                           tempUpperCriticalLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.8 integer read-only
System becomes critical when temperature rises ABOVE this level (degrees Celsius). A system shutdown is performed if object tempCriticalReaction is set to shutdown-and-poweroff.
                                           tempLowerDamageLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.9 integer read-only
Object made obsolete - no longer supported
                                           tempUpperDamageLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.10 integer read-only
Object made obsolete - no longer supported
                                           tempCurrentValue 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.11 gauge read-only
Current temperature value (degrees Celsius; -1: unknown temperature, problem with sensor, see tempSensorStatus)
                                           tempCriticalReaction 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.12 integer read-write
Reaction when a temperature gets critical (shutdown and power-off, continue...). The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'shutdown-and-poweroff': 3, 'unknown': 1, 'continue': 2.
                                           tempSensorDesignation 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.13 displaystring read-only
String describing the purpose of each temperature sensor in a housing (e.g. CPU, ambient,...). This object will substitute the tempSensorPurpose object.
                                   fansTable 1.3.6.1.4.1.231.2.10.2.2.5.2.2 no-access
Table with data of all configured cooling devices (fans)
                                       fans 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1 no-access
                                           fanCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.1 integer read-only
ID of the cabinet the cooling device (fan) is in (index, 0 based)
                                           fanNumber 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.2 integer read-only
Number of the fan in this cabinet (index, 0 based)
                                           fanStatus 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.3 integer read-only
Status of this fan (OK, failed...). Status disabled(2) is no longer used. Status prefailure-predicted(5) means the fan will fail in near future. Status redundant-fan-failed(6) means a redundant fan has failed, the system is not yet critical. Status not-manageable(7) is a fan that is available but has no management facilities. Status not-present(8) can be a hot-plug fan that is currently removed. Enumeration: 'not-manageable': 7, 'ok': 3, 'prefailure-predicted': 5, 'unknown': 1, 'disabled': 2, 'redundant-fan-failed': 6, 'not-present': 8, 'fail': 4.
                                           fanPurpose 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.4 integer read-only
Purpose of this fan (housing, component, CPU on-chip, power supply...). Purpose disabled(2) is currently not used. Enumeration: 'not-available': 7, 'unknown': 1, 'housing': 5, 'component': 4, 'disable': 2, 'cpu-onchip': 3, 'power-supply': 6.
                                           fanPositionX 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.5 integer read-only
Fax X position - obsolete; for fan indentifying use fanIdentification object
                                           fanPositionY 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.6 integer read-only
Fax Y position - obsolete; for fan indentifying use fanIdentification object
                                           fanPositionZ 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.7 integer read-only
Fax Z position - obsolete; for fan indentifying use fanIdentification object
                                           fanCurrentSpeed 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.8 gauge read-only
Current speed of the fan (in revolutions per minute, -1 = unknown)
                                           fanNominalMaximumSpeed 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.9 integer read-only
Nominal speed of the fan (in revolutions per minute) on maximum power; the speed is measured the first time the agent is installed and than compared daily to the current speed on maximum power to detect a fan prefailure (-1 = unknown).
                                           fanCurrentMaximumSpeed 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.10 gauge read-only
Current speed of the fan (in revolutions per minute) on maximum power (-1 = unknown).
                                           fanMaximumSpeedCriticalLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.11 integer read-only
Obsolete - no longer supported.
                                           fanMinimumSpeed 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.12 integer read-only
Obsolete - no longer supported.
                                           fanFailReaction 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.14 integer read-write
Reaction when a fan has failed (shutdown and power-off, continue...). The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'shutdown-and-poweroff': 3, 'unknown': 1, 'continue': 2.
                                           fanFailShutdownDelay 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.15 integer read-write
Delay time (in seconds) when shutdown should commit on fan fail (if shutdown-and-off is configured, 0 = immediately, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
                                           fanDesignation 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.16 displaystring read-write
String describing the purpose of each fan in a housing (e.g. CPU, Power Supply,...). This object will substitute the fanPurpose object.
                                           fanIdentification 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.17 displaystring read-write
String identifying each fan in a housing (e.g. CPU0, CPU1, PS0...)
                                   fanDailyTestTime 1.3.6.1.4.1.231.2.10.2.2.5.2.3 integer read-write
Daily time when to automatically test fan speeds (in minutes since midnight; -1 = unknown, automatic fan test not supported). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
                                   fanStartTest 1.3.6.1.4.1.231.2.10.2.2.5.2.4 integer read-write
Start test of all fans to get the speed at maximum power (this test is normally started automatically once a day). Reading this object just returns the value 0. Enumeration: 'start-test': 1.
                               errorHandling 1.3.6.1.4.1.231.2.10.2.2.5.3
                                   eventLogTable 1.3.6.1.4.1.231.2.10.2.2.5.3.1 no-access
Table with event log entries (can also contain critical errors when an ErrorLog for critical errors is not available)
                                       eventLog 1.3.6.1.4.1.231.2.10.2.2.5.3.1.1 no-access
                                           eventLogEntryNumber 1.3.6.1.4.1.231.2.10.2.2.5.3.1.1.1 integer read-only
Entry number in eventLogTable (index, 0 based)
                                           eventLogMessageData 1.3.6.1.4.1.231.2.10.2.2.5.3.1.1.2 octet string read-only
Non-critical message log entry as described above
                                   eventLogMaxEntries 1.3.6.1.4.1.231.2.10.2.2.5.3.2 integer read-only
Number of EventLog entries (can be used to directly get all table entries with one varbind list)
                                   errorLogTable 1.3.6.1.4.1.231.2.10.2.2.5.3.3 no-access
Table with major and critial error log entries (can be missing on some hardware platforms)
                                       errorLog 1.3.6.1.4.1.231.2.10.2.2.5.3.3.1 no-access
                                           errorLogEntryNumber 1.3.6.1.4.1.231.2.10.2.2.5.3.3.1.1 integer read-only
Entry number in critical errorLogTable (index, 0 based)
                                           errorLogMessageData 1.3.6.1.4.1.231.2.10.2.2.5.3.3.1.2 octet string read-only
Major/critical message log entry as described above
                                   errorLogMaxEntries 1.3.6.1.4.1.231.2.10.2.2.5.3.4 integer read-only
Number of ErrorLog entries (can be used to directly get all table entries with one varbind list)
                                   hardwareWatchdogStatus 1.3.6.1.4.1.231.2.10.2.2.5.3.5 integer read-only
Status of the hardware watchdog (periodically restarted by the server management BIOS). The hardware watchdog is only supported on SMI based management hardware, not for micro controller hardware. Enumeration: 'not-available': 4, 'unknown': 1, 'enable': 3, 'disable': 2.
                                   hardwareWatchdogTime 1.3.6.1.4.1.231.2.10.2.2.5.3.6 integer read-only
Timeout time of the hardware watchdog (in seconds, -1 = unknown)
                                   hardwareWatchdogEnable 1.3.6.1.4.1.231.2.10.2.2.5.3.7 integer read-write
Enable/disable the hardware watchdog. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'unknown': 1, 'enable': 3, 'disable': 2.
                                   softwareWatchdogStatus 1.3.6.1.4.1.231.2.10.2.2.5.3.8 integer read-only
Status of the software watchdog (periodically restarted by the server management agent) Enumeration: 'not-available': 4, 'unknown': 1, 'enable': 3, 'disable': 2.
                                   softwareWatchdogTime 1.3.6.1.4.1.231.2.10.2.2.5.3.9 integer read-write
Timeout time of the software watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
                                   softwareWatchdogEnable 1.3.6.1.4.1.231.2.10.2.2.5.3.10 integer read-write
Enable/disable the software watchdog. The value unknown(-1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'unknown': 1, 'enable': 3, 'disable': 2.
                                   softwareWatchdogAction 1.3.6.1.4.1.231.2.10.2.2.5.3.11 integer read-write
Behavior when the software watchdog timeout occurs (reboot, continue...). This value is only used if the watchdog is enabled. If set to continue and the watchdog has timeout, it will only be logged and no reset happens. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'unknown': 1, 'continue': 2, 'power-cycle': 5, 'nmi': 4, 'reboot': 3.
                                   bootWatchdogStatus 1.3.6.1.4.1.231.2.10.2.2.5.3.12 integer read-only
Status of the boot watchdog (started at system boot, reset by the server management agent). If the SC agent is not started within the specified time, the management controller assumes the system did not boot correctly and executes system reboot. Enumeration: 'not-available': 4, 'unknown': 1, 'enable': 3, 'disable': 2.
                                   bootWatchdogTime 1.3.6.1.4.1.231.2.10.2.2.5.3.13 integer read-write
Timeout time of the boot watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
                                   bootWatchdogEnable 1.3.6.1.4.1.231.2.10.2.2.5.3.14 integer read-write
Enable/disable the boot watchdog. The value unknown(-1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'unknown': 1, 'enable': 3, 'disable': 2.
                                   bootWatchdogAction 1.3.6.1.4.1.231.2.10.2.2.5.3.15 integer read-write
Behavior when the boot watchdog timeout occurs (reboot, continue...). This value is only used if the watchdog is enabled. If set to continue and the watchdog has timeout, it will only be logged and no reset happens. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'unknown': 1, 'continue': 2, 'power-cycle': 5, 'nmi': 4, 'reboot': 3.
                               systemBoard 1.3.6.1.4.1.231.2.10.2.2.5.4
                                   cpuTable 1.3.6.1.4.1.231.2.10.2.2.5.4.1 no-access
Table with CPU information
                                       cpu 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1 no-access
                                           cpuTableIndex 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.1 integer read-only
Number of the CPU in the CpuTable (index, 0 based)
                                           cpuType 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.2 integer read-only
Type of the CPU (486, Pentium, R2000...) Enumeration: 'r4000': 104, 'r5000': 105, 'unknown-mips': 101, 'unknown': 1, 'r12000': 112, 'i486': 4, 'r10000': 110, 'r3000': 103, 'pentium-pro': 6, 'pentium': 5, 'r2000': 102, 'i386': 3.
                                           cpuFrequency 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.3 integer read-only
Frequency of the CPU (in MHz, -1 = unknown)
                                           cpuStep 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.4 integer read-only
Step (version) of the CPU (-1 = unknown)
                                           cpuStatus 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.6 integer read-only
Status of a CPU: unknown(1) : CPU status could not be evaluated disabled(2) : CPU was manually disabled in BIOS setup ok(3) : CPU is available and operating properly not-present(4) : CPU is not available, empty socket error(5) : CPU has encountered errors but is still in use fail(6) : CPU has failed and is disabled missing-termination(7): CPU socket needs a terminator module when not populated but the terminator is missing prefailure-warning(8) : CPU has too many correctable errors within a certain time period Enumeration: 'ok': 3, 'prefailure-warning': 8, 'unknown': 1, 'disabled': 2, 'not-present': 4, 'error': 5, 'fail': 6, 'missing-termination': 7.
                                           cpuModel 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.7 integer read-only
Model of the CPU (-1 = unknown)
                                           cpuName 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.8 displaystring read-only
Name of the CPU (e.g. 'Pentium', 'Pentium Pro' ...) as text string
                                           cpuSocketDesignation 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.9 displaystring read-only
String containing the socket designation of a CPU. This is the same text that is written on the system board.
                                           cpuManufacturer 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.10 displaystring read-only
String containing the CPU manufacturer.
                                           cpuNrLogicalsPerPhysical 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.11 integer read-only
Number of logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical CPUs of a hyper-threading CPU.
                                           cpuCacheL1Size 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.12 integer read-only
Level 1 cache size (kByte) of a physical CPU (0 if unknown or not available).
                                           cpuCacheL2Size 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.13 integer read-only
Level 2 cache size (kByte) of a physical CPU (0 if unknown or not available).
                                           cpuCacheL3Size 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.14 integer read-only
Level 3 cache size (kByte) of a physical CPU (0 if unknown or not available).
                                           cpuNrCoresPerPhysical 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.15 integer read-only
Number of cores within one physical CPU (for multi-core CPUs).
                                   secondLevelCacheSize 1.3.6.1.4.1.231.2.10.2.2.5.4.2 integer read-only
Size of the second level cache (in kBytes, 0 if not available or disabled, -1 = unknown). Object will be made obsolete in next releases; use cpuCacheL2Size instead!
                                   secondLevelCacheWritePolicy 1.3.6.1.4.1.231.2.10.2.2.5.4.3 integer read-only
Write policy of the second level cache (write-back, write-through). Object will be made obsolete in next releases (no longer required). Enumeration: 'write-through': 3, 'unknown': 1, 'write-back': 2.
                                   physicalMemorySize 1.3.6.1.4.1.231.2.10.2.2.5.4.4 integer read-only
Size of the whole physical memory on the system board (in MBytes, -1 = unknown)
                                   baseMemorySize 1.3.6.1.4.1.231.2.10.2.2.5.4.5 integer read-only
Size of the base memory (below 1 MB) on the system board (in kBytes, -1 = unknown)
                                   extendedMemorySize 1.3.6.1.4.1.231.2.10.2.2.5.4.6 integer read-only
Size of the extended memory (above 1 MB) on the system board (in MBytes, -1 = unknown)
                                   utilizationMethod 1.3.6.1.4.1.231.2.10.2.2.5.4.7 integer read-write
Method to get utilization values: take-snapshot-now: get all values and store them to have all values at one certain time (set this object each time you want to get new values) get-current-values (default): get the values directly without buffering. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'take-snapshot-now': 2, 'unknown': 1, 'get-current-values': 3.
                                   utilizationPciLoad 1.3.6.1.4.1.231.2.10.2.2.5.4.8 gauge read-only
Load on the PCI bus (in percent; -1 if unknown); do no longer use this object for new implementations; object replaced by pciUtilizationTable.
                                   utilizationEisaLoad 1.3.6.1.4.1.231.2.10.2.2.5.4.9 gauge read-only
Load on the EISA bus (in percent; -1 if unknown)
                                   memoryModulesTable 1.3.6.1.4.1.231.2.10.2.2.5.4.10 no-access
Table with memory module descripitions
                                         memoryModules 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1 no-access
                                             memModuleNumber 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.1 integer read-only
Module number (index, 0 based)
                                             memModuleBank 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.2 integer read-only
Bank number the module belongs to (-1 = unknown).
                                             memModuleStatus 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.3 integer read-only
Status of the memory module socket (OK, fail, disabled...). unknown(1) : module status could not be evaluated error(2) : module has encountered errors but is still in use ok(3) : module is available and operating properly not-available(4) : empty socket, module is not available fail(5) : module has failed and is disabled prefailure-warning(6) : module has too many correctable errors within a certain time period hot-space(7) : module is a hot-spare (standby) module, which can be used as a run-time-replacement for failed modules mirror(8) : module is part of a mirror disabled(9) : module was manually disabled in BIOS setup raid(10) : module is part of a memory module RAID system Enumeration: 'not-available': 4, 'ok': 3, 'prefailure-warning': 6, 'unknown': 1, 'error': 2, 'disabled': 9, 'mirror': 8, 'fail': 5, 'raid': 10, 'hot-spare': 7.
                                             memModuleErrors 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.4 counter read-only
Number of (parity) errors in this module since last error count reset (-1 = unknown)
                                             memModuleStartAddress 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.5 integer read-only
Start address of the bank this memory belongs to (-1 = unknown). This object is obsolete when the main memory size exceeds 4 GByte. Use new object memModuleStartAddressMB instead.
                                             memModuleSize 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.6 integer read-only
Size of this memory module (in bytes, -1 = unknown). This object is obsolete when the module's size exceeds 4 GByte. Use new object memModuleSizeMB instead.
                                             memModuleType 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.7 integer read-only
Type of memory module (Parity, NoParity, ECD, EDO...). Will be made obsolete in next agent releases!!! Use memModuleType2 for newer implementations! Enumeration: 'edc': 6, 'no-parity': 3, 'parity-or-edc': 5, 'unknown': 1, 'edo': 7, 'synchrone-edo': 8, 'other': 2, 'parity': 4.
                                             memModuleType2 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.8 integer read-only
Information about the type of a memory module (Parity, ECC, EDO, SIMM, DIMM...). The type is a combination of one or more bits. Bit field: Bit 0 - Other Bit 1 - Unknown Bit 2 - Standard Bit 3 - Fast page mode Bit 4 - EDO Bit 5 - Parity Bit 6 - ECC Bit 7 - SIMM Bit 8 - DIMM Bit 9 - RIMM Unused bits are set to zero.
                                             memModuleSocketDesignation 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.9 displaystring read-only
String containing the socket designation of a memory module. This is the same text that is written on the system board.
                                             memModuleCorrectableErrors 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.10 counter read-only
Number of correctable errors in this module since last error count reset (-1 = unknown)
                                             memModuleApproved 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.11 integer read-only
Information whether the memory module has been approved by the system vendor. unknown(1) is given when a module is not available or module cannot be accessed; no(2) when no approval information is found; yes(3) when a valid approval information is found in the module. Enumeration: 'unknown': 1, 'yes': 3, 'no': 2.
                                             memModuleStartAddressMB 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.12 integer read-only
Start address (in MBytes) of the bank this memory belongs to (-1 = unknown). This object makes the object memModuleStartAddress obsolete (4 GByte limit).
                                             memModuleSizeMB 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.13 integer read-only
Size (in MBytes) of this memory module (-1 = unknown). This object makes the object memModuleSize obsolete (4 GByte limit).
                                   memoryErrorCounterReset 1.3.6.1.4.1.231.2.10.2.2.5.4.11 integer read-write
Reset the memory module error counters (and set a new start time), reading this object just returns the value 0. Enumeration: 'reset': 1.
                                   memoryErrorCounterStartTime 1.3.6.1.4.1.231.2.10.2.2.5.4.12 integer read-only
Time when memory module error counters were started (seconds since 1/1/1970, -1 = unknown)
                                   pciUtilizationTable 1.3.6.1.4.1.231.2.10.2.2.5.4.13 no-access
Table with PCI bus utilization data; independent of utilizationMethod object, update method for this table is always get-current-values. The number of entries in this table can be read from MIB object sniScNumberPciBusses.
                                         pciUtilization 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1 no-access
                                             pciUtilBusNumber 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.1 integer read-only
PCI bus number (index, 1..n)
                                             pciUtilBusLoad 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.2 gauge read-only
PCI bus load (in percent, 0xffffffff if unknown)
                                             pciUtilBusTransferRate 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.3 gauge read-only
PCI bus data transfer rate (in MBytes/second, 0xffffffff if unknown)
                                             pciUtilBusEfficiency 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.4 gauge read-only
PCI bus efficiency, ratio of data transfer rate through bus load (in percent); avarage value over all devices on this PCI bus; optimum value is 100 percent (0xffffffff if unknown).
                                   sniScBiosVersionString 1.3.6.1.4.1.231.2.10.2.2.5.4.14 displaystring read-only
String containing complete BIOS version, e.g. V4.05 R1.03.887
                                   sniScNumberCpuSockets 1.3.6.1.4.1.231.2.10.2.2.5.4.15 integer read-only
Number of CPU sockets available on the system board. This is not the number of currently installed CPUs! This object also describes the number of entries in the 'cpuTable' (-1 = unknown).
                                   sniScNumberMemoryModules 1.3.6.1.4.1.231.2.10.2.2.5.4.16 integer read-only
Number of memory module sockets available on the system board (or memory extension board). This is not the number of currently installed memory modules! This object also describes the number of entries in the 'memoryModulesTable' (-1 = unknown).
                                   sniScNumberPciBusses 1.3.6.1.4.1.231.2.10.2.2.5.4.17 integer read-only
Number of PCI busses available in the system (-1 = unknown).
                                   totalMemoryUsage 1.3.6.1.4.1.231.2.10.2.2.5.4.18 gauge read-only
Total system memory usage (virtual and physical, in KBytes, -1 = unknown)
                                   totalMemoryUsagePercent 1.3.6.1.4.1.231.2.10.2.2.5.4.19 gauge read-only
Total system memory usage (virtual and physical, in percent, -1 = unknown)
                                   physicalMemoryUsage 1.3.6.1.4.1.231.2.10.2.2.5.4.20 gauge read-only
Physical system memory usage (in KBytes, -1 = unknown)
                                   physicalMemoryUsagePercent 1.3.6.1.4.1.231.2.10.2.2.5.4.21 gauge read-only
Physical system memory usage (in percent, -1 = unknown)
                                   totalMemoryAvailable 1.3.6.1.4.1.231.2.10.2.2.5.4.22 gauge read-only
Total system memory available (virtual and physical, in KBytes, -1 = unknown)
                                   physicalMemoryAvailable 1.3.6.1.4.1.231.2.10.2.2.5.4.23 gauge read-only
Physical system memory available (in KBytes, -1 = unknown)
                                   physicalMemoryOsSize 1.3.6.1.4.1.231.2.10.2.2.5.4.24 integer read-only
Total size of the whole physical memory available to the operating system; this value is similar to 'physicalMemorySize', but may be less if the system has mirror or hot spare memory modules (in MBytes, -1 = unknown)
                               pagerSetup 1.3.6.1.4.1.231.2.10.2.2.5.5
                                   pagerUserTable 1.3.6.1.4.1.231.2.10.2.2.5.5.1 no-access
Table with info of the users that should be paged
                                       pagerUser 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1 no-access
                                           pagerUserIndex 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.1 integer read-only
Index into pager user table (0 based)
                                           pagerType 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.2 integer read-write
Type of the installed pager (signal, numeric, alfa-numeric). The value unknown(1) and not-available(2) cannot be set, a SET will deliver 'badValue'. Enumeration: 'not-available': 2, 'unknown': 1, 'signal': 3, 'alfa-numeric': 5, 'numeric': 4.
                                           pagerUserName 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.3 displaystring read-write
Name of the pager user
                                           pagerUserDescription 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.4 displaystring read-write
Description (function, optional) of the pager user
                                           pagerActive 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.5 integer read-write
Describes whether this pager is active and should be called. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'not-active': 2, 'unknown': 1, 'active': 3.
                                           pagerNumber 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.6 displaystring read-write
User ID number of the user's pager
                                           pagerServiceProviderNumber 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.7 displaystring read-write
Telephone dial number of the pager service provider (can also contain additional modem dial characters)
                                           pagerActivityPrompt 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.8 displaystring read-write
Prompt string that should be received before pager number can be sent
                                           pagerTimeModel 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.9 displaystring read-write
Encoded string containing a pager time model (when should which user be paged); this value is currently not used.
                                   pagerInitString 1.3.6.1.4.1.231.2.10.2.2.5.5.2 displaystring read-only
Init string that will be sent to the pager modem before the dialing begins
                                   pagerServerNumber 1.3.6.1.4.1.231.2.10.2.2.5.5.3 integer read-write
Number of this server. It is sent together with the error number as a message to the user's pager (-1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
                                   pagerComPort 1.3.6.1.4.1.231.2.10.2.2.5.5.4 integer read-write
COM port number (1...4) the pager modem is connected to. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'com1': 2, 'unknown': 1, 'com3': 4, 'com2': 3, 'com4': 5.
                                   pagerComPortBaudRate 1.3.6.1.4.1.231.2.10.2.2.5.5.5 integer read-write
Baud rate of the pager COM port. Following values are supported: 1200, 2400, 4800, 9600, 19200 (-1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
                                   pagerComPortParity 1.3.6.1.4.1.231.2.10.2.2.5.5.6 integer read-write
Parity check configuration for the pager COM port. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'even': 2, 'none': 4, 'space': 6, 'unknown': 1, 'mark': 5, 'odd': 3.
                                   pagerComPortNumBits 1.3.6.1.4.1.231.2.10.2.2.5.5.7 integer read-write
Number of bits per byte on the pager COM port (7, 8, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
                                   pagerComPortFlowControl 1.3.6.1.4.1.231.2.10.2.2.5.5.8 integer read-write
Flow control method of the pager COM port (Hardware, XON/XOFF...). The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'hardware': 3, 'unknown': 1, 'none': 2, 'xon-xoff': 4.
                                   pagerModemName 1.3.6.1.4.1.231.2.10.2.2.5.5.9 displaystring read-write
Optional modem name or type; can be used just as info to be displayed.
                               standardBiosSetup 1.3.6.1.4.1.231.2.10.2.2.5.7
                                   stdSetupPasswordEnable 1.3.6.1.4.1.231.2.10.2.2.5.7.1 integer read-only
Tells whether a password is configured for the standard BIOS (read-only) Enumeration: 'unknown': 1, 'enable': 3, 'disable': 2.
                                   stdSetupBootSource 1.3.6.1.4.1.231.2.10.2.2.5.7.2 integer read-write
Source medium to boot from: Normal system or diagnostic system standard(2): standard boot diag-system(4): boot from alternate diagnostic system The source the diagnostic system is booted from is selected in object 'srvSetupRebootFailAction'. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'unknown': 1, 'diag-system': 4, 'standard': 2.
                                   stdSetupPostErrorHalt 1.3.6.1.4.1.231.2.10.2.2.5.7.3 integer read-write
Describes what to do when a POST error has occured (halt on any error, no halt on any error...). The values unknown(1) and other(9) cannot be set, a SET will deliver 'badValue'. Enumeration: 'halt-on-any-error': 2, 'unknown': 1, 'other': 9, 'no-halt-on-any-error': 3.
                                   stdSetupSerialInterface1 1.3.6.1.4.1.231.2.10.2.2.5.7.4 integer read-write
The COM port which the on-board serial interface 1 is mapped to (1...4). The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'com-4': 6, 'com-1': 3, 'com-3': 5, 'com-2': 4, 'unknown': 1, 'disable': 2, 'auto': 9.
                                   stdSetupSerialInterface2 1.3.6.1.4.1.231.2.10.2.2.5.7.5 integer read-write
The COM port which the on-board serial interface 2 is mapped to (1...4). The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'com-4': 6, 'com-1': 3, 'com-3': 5, 'com-2': 4, 'unknown': 1, 'disable': 2, 'auto': 9.
                                   stdSetupParallelInterface 1.3.6.1.4.1.231.2.10.2.2.5.7.6 integer read-write
The LPT port which the on-board parallel interface is mapped to (1...3). The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'lpt-2': 4, 'unknown': 1, 'lpt-1': 3, 'lpt-3': 5, 'disable': 2, 'auto': 9.
                                   stdSetupFloppyController 1.3.6.1.4.1.231.2.10.2.2.5.7.7 integer read-write
Describes whether the floppy controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'unknown': 1, 'enable': 3, 'disable': 2.
                                   stdSetupHarddiskController 1.3.6.1.4.1.231.2.10.2.2.5.7.8 integer read-write
Describes whether the IDE harddisk controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'unknown': 1, 'disable': 2, 'primary': 3, 'primary-and-secondary': 4.
                                   stdSetupMouseController 1.3.6.1.4.1.231.2.10.2.2.5.7.9 integer read-write
Describes whether the mouse port controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'unknown': 1, 'enable': 3, 'disable': 2.
                               serverBiosSetup 1.3.6.1.4.1.231.2.10.2.2.5.8
                                   srvSetupCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.8.1 integer read-write
Cabinet ID number of this server (-1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. Use this number as cabinetId for all tables containing a cabinet index. If unknown is delivered, 0 should be used as cabinet index.
                                   srvSetupServerRackSlot 1.3.6.1.4.1.231.2.10.2.2.5.8.2 integer read-write
Slot number (in a rack) this server is in (only for rack servers; -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. This object is currently not used.
                                   srvSetupServerGroupStart 1.3.6.1.4.1.231.2.10.2.2.5.8.3 integer read-write
deleted
                                   srvSetupServerGroupEnd 1.3.6.1.4.1.231.2.10.2.2.5.8.4 integer read-write
deleted
                                   srvSetupServerGroupMembers 1.3.6.1.4.1.231.2.10.2.2.5.8.5 integer read-write
deleted
                                   srvSetupSeGroupStart 1.3.6.1.4.1.231.2.10.2.2.5.8.6 integer read-write
deleted
                                   srvSetupSeGroupEnd 1.3.6.1.4.1.231.2.10.2.2.5.8.7 integer read-write
deleted
                                   srvSetupSeGroupMembers 1.3.6.1.4.1.231.2.10.2.2.5.8.8 integer read-write
deleted
                                   srvSetupRemoteOnEnable 1.3.6.1.4.1.231.2.10.2.2.5.8.9 integer read-write
Describes whether remote-on via RI modem line is enabled or not available. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'not-available': 4, 'unknown': 1, 'enable': 3, 'disable': 2.
                                   srvSetupMaxRestartRetries 1.3.6.1.4.1.231.2.10.2.2.5.8.10 integer read-write
Maximum number of retries to reboot/restart the server when a shutdown (and power-off) had occured. After this number of retries the action defined in 'srvSetupRebootFailAction' will be executed (-1 = unknown, no retries). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
                                   srvSetupRebootFailAction 1.3.6.1.4.1.231.2.10.2.2.5.8.11 integer read-write
Describes the action on a specified number of failed reboot retries (srvSetupMaxRestartRetries=0): unknown(1) - diagnostic system cannot be determined (cannot be SET) switch-off(2) - no diag system, final power-off ide-diag-disk(3) - boot diag system from IDE disk no-diag-system(4) - no diag system available remote-image-disk(5) - boot from remote image (over LAN) pxe(6) - boot from PXE (Preboot eXecution Environment) rsb-usb(7) - boot from RSB remote source (via USB interface) bmc-remote(8) - boot from BMC from remote storage This value is also the source to be booted from when object 'stdSetupBootSource' is set to 'diag-system'. Enumeration: 'bmc-remote': 8, 'unknown': 1, 'ide-diag-disk': 3, 'rsb-usb': 7, 'remote-image-disk': 5, 'no-diag-system': 4, 'switch-off': 2, 'pxe': 6.
                                   srvSetupRebootFailPager 1.3.6.1.4.1.231.2.10.2.2.5.8.12 integer read-write
Describes whether the pager should be activated when reboot after error shutdown had occured. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'pager-disabled': 2, 'unknown': 1, 'page-on-every-error-reboot': 3.
                                   srvSetupSeGroupNumber 1.3.6.1.4.1.231.2.10.2.2.5.8.13 integer read-write
Group number for storage extension communication bus. Legal values are 0..9, -1 = unknown. The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
                                   srvSetupRestartRetriesDefault 1.3.6.1.4.1.231.2.10.2.2.5.8.14 integer read-write
Default number of retries to reboot/restart the server when a shutdown (and power-off) had occured. This value will be copied to object srvSetupMaxRestartRetries by the user to reset the counter to its original (default) value (-1 = unknown, no retries). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
                               powerOnOff 1.3.6.1.4.1.231.2.10.2.2.5.9
                                   onOffTimesTable 1.3.6.1.4.1.231.2.10.2.2.5.9.1 no-access
Table with system power on/off times; power-on will be performed by the real-time clock, power-off (with shutdown) by the operating system (system control service); table must be enabled before using
                                       onOffTimes 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1 no-access
                                           onOffWeekday 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.1 integer read-only
Day of the week the times should act upon (index, 1 based); 1 = Sunday, 2 = Monday...
                                           onTime 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.2 integer read-write
Time the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed.
                                           offTime 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.3 integer read-write
Time the system should be switched off (by the operating system; in minutes since midnight; -1 = disabled, no off time). Only values -1 and 0..1439 are allowed.
                                   shutdownDelayTime 1.3.6.1.4.1.231.2.10.2.2.5.9.2 integer read-write
The delay time (in minutes) the agent should wait before executing a shutdown (with doShutdown); 0 = default = shutdown immediately; -1 = unknown. The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
                                   doShutdown 1.3.6.1.4.1.231.2.10.2.2.5.9.3 integer read-write
Execute a shutdown; argument tells what kind of shutdown: shutdown: wait for user to switch off or reboot shutdown-and-off: switch off after shutdown shutdown-and-reboot: reboot after shutdown abort-pending-shutdown: abort a delayed shutdown immediately (if not already initiated) Reading this object just returns the value 0. Enumeration: 'shutdown-and-off': 2, 'abort-pending-shutdown': 4, 'shutdown': 1, 'shutdown-and-reboot': 3.
                                   powerOnCounts 1.3.6.1.4.1.231.2.10.2.2.5.9.4 counter read-only
Tells how often the server was switched on in its life (-1 = unknown)
                                   powerOnDurationHours 1.3.6.1.4.1.231.2.10.2.2.5.9.5 counter read-only
Tells how long the system was switched on in its life (in hours; -1 = unknown)
                                   powerOffDurationHours 1.3.6.1.4.1.231.2.10.2.2.5.9.6 counter read-only
Tells how long the system was switched off in its life (in hours; -1 = unknown)
                                   errorOffRestartDelay 1.3.6.1.4.1.231.2.10.2.2.5.9.7 integer read-write
Delay (in minutes) when the system should be automatically switched on again (by real-time clock) after an error power-off (-1 = no switch-on function). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. On some platforms only the values 1, 2, 3, 5, 7, 10, 15 and 20 can be set. Values between these numbers will be rounded.
                                   lastPostStatus 1.3.6.1.4.1.231.2.10.2.2.5.9.8 integer read-only
Describes whether the last (current) POST (power on self test) was errornous. Object is now obsolete - use object systemBootStatus instead! Enumeration: 'unknown': 1, 'errors': 3, 'ok': 2.
                                   lastPowerOffSource 1.3.6.1.4.1.231.2.10.2.2.5.9.9 integer read-only
Reason why the system was switched off last time Enumeration: 'MMB-continuous-operation': 36, 'remote-off': 11, 'fan-fail': 6, 'power-limiting': 35, 'watchdog-power-cycle': 37, 'temperature-damage': 8, 'keyboard': 29, 'watchdog': 10, 'power-supply-failure': 9, 'hardware-reset': 23, 'ac-fail': 4, 'clock': 5, 'unknown': 1, 'temperature-critical': 7, 'software-command': 2, 'reset-button': 25, 'peripheral-bus-error': 13, 'firmware-restart': 242, 'cpu-error': 14, 'remote-manager-reset': 32, 'power-button': 3, 'nmi': 20, 'warmstart': 24, 'remote-manager': 31, 'hardware-fail': 12, 'ac-fail-reboot': 26, 'housing-opened': 243.
                                   lastPowerOnSource 1.3.6.1.4.1.231.2.10.2.2.5.9.10 integer read-only
Source the system was switched on from Enumeration: 'warmstart': 24, 'keyboard': 29, 'temperature-damage': 8, 'chipcard-reader': 30, 'watchdog': 10, 'power-supply-failure': 9, 'hardware-reset': 23, 'ac-fail': 4, 'clock': 5, 'unknown': 1, 'mgmt-processor-fail': 27, 'temperature-critical': 7, 'software-command': 2, 'power-cycle': 33, 'reset-button': 25, 'peripheral-bus-error': 13, 'pci-pme': 28, 'firmware-restart': 242, 'remote-on': 11, 'cpu-error': 14, 'remote-manager-reset': 32, 'power-button': 3, 'nmi': 20, 'fan-fail': 6, 'remote-manager': 31, 'housing-closed': 243, 'hardware-fail': 12, 'ac-fail-reboot': 26.
                                   powerOnTime 1.3.6.1.4.1.231.2.10.2.2.5.9.11 integer read-only
Time and Date the system was booted (seconds since 1/1/1970; -1 = unknown)
                                   doPowerOnOff 1.3.6.1.4.1.231.2.10.2.2.5.9.12 integer read-write
Switch the server on or off; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switch power off and switch power on again reset: perform a server reset nmi: perform a non-maskable interrupt (NMI, mainly for debugging purpose) Enumeration: 'reset': 4, 'on': 1, 'off': 2, 'power-cycle': 3, 'nmi': 5.
                                   systemBootResult 1.3.6.1.4.1.231.2.10.2.2.5.9.13 integer read-only
Result of the last server boot. Enumeration: 'no-boot-cp': 4, 'diagnostic-boot-failed': 7, 'os-boot-successful': 2, 'unknown': 1, 'diagnostic-boot-successful': 3, 'hardware-failure': 8, 'no-bootable-media': 5, 'os-failed-to-load': 6.
                                   systemBootStatus 1.3.6.1.4.1.231.2.10.2.2.5.9.14 integer read-only
Status of the current boot process. Enumeration: 'no-boot-cp': 3, 'reset': 12, 'os-shutdown': 10, 'off': 2, 'unknown': 1, 'setup': 5, 'diagnostic-shutdown': 11, 'os-boot': 6, 'self-test': 4, 'diagnostic-boot': 7, 'os-running': 8, 'diagnostic-running': 9.
                               systemControlInfo 1.3.6.1.4.1.231.2.10.2.2.5.10
                                     numberCabinetsConfigured 1.3.6.1.4.1.231.2.10.2.2.5.10.1 integer read-only
Number of configured cabinets (server and storage extensions, at least 1: the server itself)
                                     numberCabinetsDetected 1.3.6.1.4.1.231.2.10.2.2.5.10.2 gauge read-only
Number of detected cabinets (server and storage extensions, at least 1: the server itself). This is also the number of entries in cabinetInfosTable.
                                     cabinetInfosTable 1.3.6.1.4.1.231.2.10.2.2.5.10.3 no-access
Table with data of all configured cabinets
                                         cabinetInfos 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1 no-access
                                             cabinetId 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.1 integer read-only
Cabinet ID number, index into the cabinet table
                                             cabinetLocation 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.2 displaystring read-write
The place where the cabinet is located (user can store any string here to identify the cabinet location)
                                             cabinetIdentNumber 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.3 displaystring read-write
System ident number (serial number) - will be a number like 'XYZZ 12345678'. XYZZ is the cabinet identifier and is mandatory. It will be used to identify the cabinet model name (i.e. PCD-5S). 12345678 is the cabinet serial number and is optional. Cabinet identifier and serial number are separated by a blank character!
                                             cabinetSystemName 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.4 displaystring read-only
System name string (i.e. PCD-5S, Primergy 150...)
                                             cabinetNumberFans 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.5 integer read-only
The number of configured cooling devices (fans) in this cabinet (-1 = unknown)
                                             cabinetNumberTempSensors 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.6 integer read-only
The number of configured temperature sensors in this cabinet (-1 = unknown)
                                             cabinetNumberPowerSupplies 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.7 integer read-only
The number of available power supplies in this cabinet (-1 = unknown)
                                             cabinetPowerSupplySlots 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.8 integer read-only
The number of power supply slots in this cabinet (is the maximum number of installable power supplies; 0 if no hot-plug slots available; -1 = unknown)
                                             cabinetUpsUsed 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.9 integer read-only
Uninterruptable power supply for this cabinet available: 0: No UPS 1..n: Index in UPS table -1: unknown
                                             cabinetBoardSerialNumber 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.10 displaystring read-only
Serial number of the cabinet's system board
                                             cabinetBoardRevision 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.11 integer read-only
Revision (GS) of the cabinet's system board (-1 = unknown). Value obsolete, use sieScCabinetBoardRevisionString instead!
                                             cabinetBoardId 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.12 displaystring read-only
Identifier string of the cabinet's system board
                                             cabinetManagementControllerType 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.13 displaystring read-only
Type of the cabinet's system management controller (i.e. SNI System Control Board)
                                             cabinetControllerFirmwareMajor 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.14 integer read-only
Firmware version (major number) of the cabinet's system management controller (-1 = unknown). This object will be replaced by sieScCabinetControllerFirmware in future versions.
                                             cabinetControllerFirmwareMinor 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.15 integer read-only
Firmware version (minor number) of the cabinet's system management controller (-1 = unknown). This object will be replaced by sieScCabinetControllerFirmware in future versions.
                                             cabinetAttribute 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.16 integer read-only
Attribute of a cabinet (Primary/secondary server, storage extension...) Enumeration: 'standalone-server': 2, 'other': 1, 'primary-server': 3, 'storage-extension': 5, 'secondary-server': 4.
                                             cabinetPowerOnStatus 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.17 integer read-only
Power-on state of the cabinet Enumeration: 'unknown': 1, 'off': 2, 'disconnected': 4, 'on': 3.
                                             cabinetStatusSummary 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.18 integer read-only
Describes the status of a cabinet (OK, degraded, error...) Enumeration: 'fail': 4, 'degraded': 2, 'ok': 1, 'error': 3.
                                             cabinetLastPoweroffSource 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.19 integer read-only
The source from which the cabinet was powered off last time Enumeration: 'power-supply-failure': 9, 'software-off': 2, 'fan-failure': 6, 'clock': 5, 'remote-off': 11, 'unknown': 1, 'critical-temperature': 7, 'power-switch': 3, 'damage-temperature': 8, 'power-fail': 4.
                                             cabinetActionAfterAcFail 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.20 integer read-write
Action on AC power resume after AC has failed. not-available(2) : function not available, behavior is hardware-defined. as-before(3) : server gets the same power state as before the AC fail. remain-off(4) : server remains off on power resume. switch-on(5) : server is always switched on on power resume. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'not-available': 2, 'unknown': 1, 'remain-off': 4, 'switch-on': 5, 'as-before': 3.
                                             cabinetBbuUsed 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.21 integer read-only
Battery buffering unit for this cabinet available. The value unknown(1) cannot be set, a SET will deliver 'badValue'. Enumeration: 'unknown': 1, 'false': 2, 'true': 3.
                                             cabinetSystemType 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.22 integer read-only
Value is obsolete. This value should no longer be used for cabinet identification. Use cabinetHousingType to identify the housing type and cabinetSystemName for the type of the cabinet!
                                             cabinetStatusDetail 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.23 integer read-only
More detailed status information from this cabinet. The StatusDetail object is set to reflect the new status. ok: (status ok) no failures detected. selftestWarning: (status degraded) the SCB firmware issued a warning condition. selftestFailure: (status error) the SCB firmware detected a failure that prevents it from functioning. powerFailure: (status degraded) the AC input at the power supply or the AC input at the UPS failed. fanFailure: (status error) A fan in this cabinet failed. The system is going to shut down. temperatureFailure: (status error) A sensor in this cabinet detected an over temperature. The system is going to shut down. communicationFailure: (status error) The SCB in the CPU cabinet has lost communication with the SCB in this cabinet. The system is going to shut down. powerOff: (status degraded) The cabinet is switched off. Enumeration: 'powerFailure': 8, 'ok': 1, 'communicationFailure': 64, 'selftestFailure': 4, 'temperatureFailure': 32, 'temperatureWarning': 256, 'fanFailure': 16, 'powerOff': 128, 'bbuError': 512, 'selftestWarning': 2.
                                             cabinetHousingType 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.24 displaystring read-only
Type string for cabinet housing type (i.e. 'P300' for all PRIMERGY 3xx housings); this object should be used to identify the cabinet instead of using object cabinetSystemType (i.e. for painting pictures in management applications)
                                             cabinetFrontDoorStatus 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.25 integer read-only
Status of the cabinet's front door Enumeration: 'unknown': 1, 'open': 2, 'closed': 3.
                                             cabinetHousingOpenStatus 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.26 integer read-only
Status describing whether the housing is open or closed Enumeration: 'unknown': 1, 'open': 2, 'closed': 3.
                                             sieScCabinetNumberVoltages 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.27 integer read-only
Number of entries in power supply voltage table
                                             sieScCabinetControllerFirmware 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.28 displaystring read-only
The cabinet's system management controller firmware version (i.e. '1.1.4.88'). This object will replace the previous objects cabinetControllerFirmwareMinor and cabinetControllerFirmwareMajor.
                                             sieScCabinetBoardRevisionString 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.29 displaystring read-only
Revision string (GS, WGS...) of the cabinet's system board. This object replaces the previous object cabinetBoardRevision.
                                             sieScCabinetAdministrativeURL 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.30 displaystring read-only
Provides a URL that may be used by a front-end to start a web browser and connect it directly to the cabinet's administrative web server (e.g. https://10.0.0.2:443/foobar.html).
                                             sieScRemcsId 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.31 displaystring read-only
REMCS system identification string (binary data): Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID for Company Name MM...M : 12byte : Model Name mm...m : 12byte : Device Name CC : 2byte : Checksum nn...n : 12byte : Serial number
                                     statusSummary 1.3.6.1.4.1.231.2.10.2.2.5.10.4 integer read-only
Value is obsolete Enumeration: 'fail': 4, 'degraded': 2, 'ok': 1, 'error': 3.
                                     serverType 1.3.6.1.4.1.231.2.10.2.2.5.10.5 integer read-only
Value is obsolete. This value should no longer be used for server identification. Use serverHousingType to identify the housing type and cabinetSystemName for the type of the server!
                                     serverHousingType 1.3.6.1.4.1.231.2.10.2.2.5.10.6 displaystring read-only
Type string for cabinet housing type (i.e. 'P300' for all PRIMERGY 3xx housings); this object should be used to identify the cabinet instead of using object serverType (i.e. for painting pictures in management applications). This is the same value as from object cabinetHousingType for the server cabinet.
                                     serverUUID 1.3.6.1.4.1.231.2.10.2.2.5.10.7 displaystring read-only
Universal Unique ID (UUID) number - this is a world wide unique ID number of the server. Can be used for identifying a server. The UUID string format is like this: 157E465A-A4AC-D711-A847-DD85CECD12EC
                               powerSupply 1.3.6.1.4.1.231.2.10.2.2.5.11
                                     powerSuppliesTable 1.3.6.1.4.1.231.2.10.2.2.5.11.1 no-access
Table with power supply groups in the cabinets
                                         powerSupplies 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1 no-access
                                             powerSupplyCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.1 integer read-only
Cabinet ID, index into the power supply table (0 based)
                                             powerSupplyStatus 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.2 integer read-only
Status of the cabinet's power supply group; ok: all units OK, number >= minimum degraded: one or more units failed, number OK >= minimum critical: number OK < minimum. Enumeration: 'unknown': 1, 'degraded': 3, 'critical': 4, 'ok': 2.
                                             powerSupplyRedundancy 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.3 integer read-only
Number of available redundant power supply units (i.e. 2 units minimum, 3 available -> redundancy is 1, -1 = unknown)
                                     powerSupplyUnitsTable 1.3.6.1.4.1.231.2.10.2.2.5.11.2 no-access
Table with info about the configured power supply units
                                         powerSupplyUnits 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1 no-access
                                             powerSupplyUnitCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.1 integer read-only
Cabinet ID, index into the power supply unit table (0 based)
                                             powerSupplyUnitNumber 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.2 integer read-only
Power supply unit number, index into power supply unit table (0 based)
                                             powerSupplyUnitStatus 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.3 integer read-only
Status of the power supply unit (OK, failed, not present...) Enumeration: 'not-manageable': 8, 'ok': 3, 'fan-failure': 10, 'ac-fail': 5, 'unknown': 1, 'critical-temperature': 7, 'failed': 4, 'not-present': 2, 'dc-fail': 6, 'fan-failure-predicted': 9.
                                             powerSupplyUnitDesignation 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.4 displaystring read-only
Power supply unit designation. This string specifies a name/designation for the power supply unit. The designation string may not be available on some platforms.
                                     sniScVoltageTable 1.3.6.1.4.1.231.2.10.2.2.5.11.4 no-access
Table with power supply voltage information
                                         sniScVoltages 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1 no-access
                                             sniScVoltageCabinetNumber 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.1 integer read-only
Cabinet number, index into the power supply voltage table (0 based)
                                             sniScVoltageNumber 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.2 integer read-only
Power supply voltage number, index into power supply voltage table (0 based)
                                             sniScVoltageStatus 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.3 integer read-only
Status of the power supply voltage; 'not-available' maybe the voltage of an empty CPU socket; 'out-of-range' comes when the voltage is out of range; 'prefailure' is used for battery voltages and informs that the battery is predicted to fail in near future. Enumeration: 'not-available': 2, 'ok': 3, 'unknown': 1, 'out-of-range': 6, 'too-low': 4, 'battery-prefailure': 7, 'too-high': 5.
                                             sniScVoltageDesignation 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.4 displaystring read-only
Power supply voltage designation. This string specifies the voltage by clear text (e.g. 5V, 12V, 3.3V...)
                                             sniScVoltageMinimumValue 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.5 integer read-only
Power supply voltage minimum level (1/100th Volts; -1 = unknown)
                                             sniScVoltageMaximumValue 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.6 integer read-only
Power supply voltage maximum level (1/100th Volts; -1 = unknown)
                                             sniScVoltageCurrentValue 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.7 gauge read-only
Power supply voltage current level, negative voltages are reported as negative values (1/100th Volts, e.g. 330 means 3.30 Volts; -177 (0xFFFFFF4F) means -1.77 Volts; 0xFFFFFFFF = unknown)
                                             sniScVoltageNominalValue 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.8 integer read-only
Power supply voltage nominal level (1/100th Volts; -1 = unknown)
                                             sniScVoltageOutputLoad 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.9 gauge read-only
Power supply output load in percent of maximum load; 0xFFFFFFFF = unknown
                               uninterruptablePowerSupply 1.3.6.1.4.1.231.2.10.2.2.5.12
                                     upsCount 1.3.6.1.4.1.231.2.10.2.2.5.12.1 integer read-only
Number of uninterruptable power supplies (UPS) in this system (-1 = unknown)
                                     upsInfosTable 1.3.6.1.4.1.231.2.10.2.2.5.12.2 no-access
Table with uninterruptable power supplies used in this system. The index is the UPS number used in the system. One or more server or storage-extension objects can reference to a UPS entry in this table.
                                         upsInfos 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1 no-access
                                             upsNumber 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.1 integer read-only
Number of the UPS in this table (index, 1 based)
                                             upsDetected 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.2 integer read-only
Tells whether the UPS was detected Enumeration: 'unknown': 1, 'false': 2, 'true': 3.
                                             upsDischargeTime 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.3 integer read-only
Maximum time this UPS will be discharged, after that a shutdown will be performed (seconds; -1 = unknown)
                                             upsVendor 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.4 displaystring read-only
Vendor name of the UPS
                                             upsType 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.5 displaystring read-only
Type of the UPS; can be used to identify an OEM UPS with an OEM agent
                                             upsOemAgent 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.6 displaystring read-only
Object identifier of an OEM UPS MIB; no agent if empty OID
                                             upsOemAgentAddress 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.7 ipaddress read-only
IP address of an OEM UPS SNMP agent; no agent if empty
                                             upsTimeOnBatterySeconds 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.8 counter read-only
Time (in seconds) the UPS is running on battery since power fail (will be cleared on power recovery)
                                     spbbuStatus 1.3.6.1.4.1.231.2.10.2.2.5.12.3 integer read-only
Status of the service processor's backup battery (not present, OK, recharging) Enumeration: 'discharging': 7, 'ok': 3, 'unknown': 1, 'recharging': 5, 'failed': 6, 'not-present': 2, 'on-battery': 4.
                                     spbbuDischargeTime 1.3.6.1.4.1.231.2.10.2.2.5.12.4 integer read-only
Maximum time this backup battery will be discharged, after that a shutdown will be performed (seconds; -1 = unknown)
                                     spbbuTimeOnBatterySeconds 1.3.6.1.4.1.231.2.10.2.2.5.12.5 counter read-only
Time (in seconds) the backup battery is running on battery since power fail (will be cleared on power recovery)
                                     spbbuDoChargeCycle 1.3.6.1.4.1.231.2.10.2.2.5.12.6 integer read-write
Perform a discharge/charge cycle on the backup battery. Reading this object just returns the value 0. Enumeration: 'recharge': 1.
                                     spbbuChargeStatus 1.3.6.1.4.1.231.2.10.2.2.5.12.7 gauge read-only
Reads the current charge level of the rechargeable battery (in percent of the maximum capacity).
                               diagnostics 1.3.6.1.4.1.231.2.10.2.2.5.13
                                     sendTestTrap 1.3.6.1.4.1.231.2.10.2.2.5.13.1 integer read-write
Send a trap to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Reading this object just returns the value 0. Enumeration: 'send-trap': 1.
                               management 1.3.6.1.4.1.231.2.10.2.2.5.14
                                     interfaceParametersTable 1.3.6.1.4.1.231.2.10.2.2.5.14.1 no-access
Table with the interface parameters of all management channels, which are controlled by this server.
                                         interfaceParameters 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1 no-access
The interface parameters of the designated management channel interface.
                                             interfaceCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.1 integer read-only
CabinetId of the cabinet where the management channel interface resides.
                                             interfaceNumber 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.2 integer read-only
Index number of the channel management interface (index, 0 based).
                                             interfaceType 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.3 integer read-only
The interface type of the interface. Enumeration: 'lan': 2, 'other': 1, 'dial-up': 3.
                                             ipAddress 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.4 ipaddress read-only
The IP v4 address of the interface.
                                             ipAdressNetMask 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.5 ipaddress read-only
The IP v4 subnet mask of the interface.
                                             physicalAddress 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.6 physaddress read-only
The interface address of the physical layer of the interface (MAC address).
                                             phoneNumber 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.7 displaystring read-only
The telephone dial number of this interface. Only useful if the interfaceType is of type dial-up(3).
                                             interfaceChannelType 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.8 integer read-only
The managegement channel type of the interface: primary: local operating system interface secondary: local management controller LAN interface management-blade: management blade interface (in a blade server chassis) secondary-remote: remote management controller (in an RSB concentrator environment) secondary-remote-backup: backup remote management controller baseboard-controller: baseboard management controller Enumeration: 'unknown': 1, 'secondary-remote-backup': 6, 'primary': 2, 'management-blade': 4, 'secondary-remote': 5, 'baseboard-controller': 7, 'secondary': 3.
                                             dhcpConfigured 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.9 integer read-only
Defines if the ip address should be requested by a dhcp service. Enumeration: 'unknown': 1, 'configured': 2, 'not-configured': 3.
                                             controllerType 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.10 displaystring read-only
The type of the remote or baseboard management controller (for identification), like 'RSB', 'RSB S2', 'RSB S2 LP'... These names will not be changed if defined once.
                                             controllerModel 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.11 displaystring read-only
The model name of the remote management controller (for displaying), like 'Remote Service Board', 'RemoteView Service Board S2'... This name should not be used for identification, only for displaying (can be changed in different firmware versions)!
                                             controllerFWVersion 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.12 displaystring read-only
The FW version of the remote or baseboard management controller as string;
                                     serviceComponentsTable 1.3.6.1.4.1.231.2.10.2.2.5.14.2 no-access
Table with the components attached to the service processor
                                         serviceComponents 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1 no-access
The components attached to the service processor
                                             serviceComponentProcessorId 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.1 integer read-only
Id of the service processor this component is attached to (index, 0 based)
                                             serviceComponentId 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.2 integer read-only
Index number of the service component (index, 0 based)
                                             serviceComponentName 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.3 displaystring read-only
The name of the component in human readable form
                                             serviceComponentType 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.4 integer read-only
The type of the componen we are dealing with. Enumeration: 'accumulator': 4, 'lan': 2, 'other': 1, 'dial-up': 3.
                                             serviceComponentStatus 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.5 integer read-only
Describes the status of the component managed by the service processor. Degraded means that some problems have occurred. Error that the component has reported an error that prevents the component form working. Failed means that the component is no longer reacting to the agents requests. Enumeration: 'failed': 4, 'degraded': 2, 'ok': 1, 'error': 3.
                                     channelType 1.3.6.1.4.1.231.2.10.2.2.5.14.3 integer read-only
The managegement channel type of the currently used management channel. Enumeration: 'unknown': 1, 'primary': 2, 'secondary': 3.
                               trapInfo 1.3.6.1.4.1.231.2.10.2.2.5.20
                                     trapServerName 1.3.6.1.4.1.231.2.10.2.2.5.20.1 displaystring no-access
Name of server the trap occured
                                     trapTime 1.3.6.1.4.1.231.2.10.2.2.5.20.2 integer no-access
Time the trap occured (in seconds since 01/01/1970 00:00h)
                                     trapCabinetNumber 1.3.6.1.4.1.231.2.10.2.2.5.20.3 integer no-access
Number of the cabinet where the trap was generated
                                     trapObjectNumber 1.3.6.1.4.1.231.2.10.2.2.5.20.4 integer no-access
Number of the object that generated the trap (fan, temperature sensor...)
                                     trapString 1.3.6.1.4.1.231.2.10.2.2.5.20.5 displaystring no-access
Additional string to be displayed in the trap text
                                     trapMinutesRemaining 1.3.6.1.4.1.231.2.10.2.2.5.20.6 integer no-access
The estimated remaining BBU/UPS capacity in minutes. In the current implementation this is the time remaining until the system will shut down.
                                     trapSecondsOnBattery 1.3.6.1.4.1.231.2.10.2.2.5.20.7 integer no-access
See scbUPSSecondsOnBattery/scbBBUSecondsOnBattery.
                                     trapConfigLowBattTime 1.3.6.1.4.1.231.2.10.2.2.5.20.8 integer no-access
The value of trapMinutesRemaining at which a shut down is initiated. In the current implementation this is always 0.
                                     trapNumValue 1.3.6.1.4.1.231.2.10.2.2.5.20.9 integer no-access
Additional numeric value to be displayed in the trap text
                                     trapManagementInterfaceNumber 1.3.6.1.4.1.231.2.10.2.2.5.20.10 integer no-access
The number of the management channel interface.
                       sniPcSpecific 1.3.6.1.4.1.231.2.10.2.3
                       sniScb 1.3.6.1.4.1.231.2.10.2.4
                       sniOsSpecific 1.3.6.1.4.1.231.2.10.2.5
                           sniNetware 1.3.6.1.4.1.231.2.10.2.5.1
                           sniWinNt 1.3.6.1.4.1.231.2.10.2.5.2
                           sniOs2 1.3.6.1.4.1.231.2.10.2.5.3
                           sniUnix 1.3.6.1.4.1.231.2.10.2.5.4
                       sniOemComponents 1.3.6.1.4.1.231.2.10.2.6
                           sniOemDpt 1.3.6.1.4.1.231.2.10.2.6.1
                           sniOemMylex 1.3.6.1.4.1.231.2.10.2.6.2
                               sniMlxDiskArray 1.3.6.1.4.1.231.2.10.2.6.2.1
                       sniSecurity 1.3.6.1.4.1.231.2.10.2.7
                           sniSmSecurity 1.3.6.1.4.1.231.2.10.2.7.1
                       sniServerView 1.3.6.1.4.1.231.2.10.2.8
                   sniTrapMib 1.3.6.1.4.1.231.2.10.5
                         testTrap 1.3.6.1.4.1.231.2.10.20.600
Test trap to verify trap connection.
                         fanError 1.3.6.1.4.1.231.2.10.20.601
The indicated fan failed.
                         tempOk 1.3.6.1.4.1.231.2.10.20.602
The temperature of the indicated sensor has decreased to the normal level.
                         tempWarn 1.3.6.1.4.1.231.2.10.20.603
The temperature of the indicated sensor has reached the warning level.
                         tempCritical 1.3.6.1.4.1.231.2.10.20.604
The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled.
                         trapOnBattery 1.3.6.1.4.1.231.2.10.20.606
The UPS is operating on battery power or the power supply is drawing current from the backup battery unit (BBU). This status is persistent and is resent at one minute intervals until the mains returns or the system is switched off.
                         trapOnMains 1.3.6.1.4.1.231.2.10.20.607
The mains voltage returned after a power failure.
                         selftestWarning 1.3.6.1.4.1.231.2.10.20.608
Currently the only possible warning is: SCB battery (nearly) empty.
                         selftestError 1.3.6.1.4.1.231.2.10.20.609
The Server Management controller failed.
                         svCommunicationFailure 1.3.6.1.4.1.231.2.10.20.610
Communication with the Server Management controller lost.
                         scbUnconfiguredUPSDetected 1.3.6.1.4.1.231.2.10.20.611
A UPS has been detected, but no UPS is configured. This trap will be repeated every 60 minutes until the condition is removed.
                         scbUPSNotdetected 1.3.6.1.4.1.231.2.10.20.612
A UPS is configured, but no UPS has been detected. This trap will be repeated every 60 minutes until the condition is removed.
                         scbUnconfiguredBBUDetected 1.3.6.1.4.1.231.2.10.20.613
A BBU has been detected, but no BBU is configured. This trap will be repeated every 60 minutes until the condition is removed.
                         scbBBUNotdetected 1.3.6.1.4.1.231.2.10.20.614
A BBU is configured, but no BBU has been detected. This trap will be repeated every 60 minutes until the condition is removed.
                         notEnoughCabinets 1.3.6.1.4.1.231.2.10.20.615
One or more storage extensions missing.
                         tooManyCabinets 1.3.6.1.4.1.231.2.10.20.616
The actual number of storage extensions is higher than the configured number.
                         cabinetSwitchedOff 1.3.6.1.4.1.231.2.10.20.617
The cabinet has been switched off.
                         cabinetSwitchedOn 1.3.6.1.4.1.231.2.10.20.618
The cabinet has been switched on.
                         internalError 1.3.6.1.4.1.231.2.10.20.620
The agent has detected an internal error.
                         serverShutdown 1.3.6.1.4.1.231.2.10.20.621
The server is being shut down.
                         fanCriticalError 1.3.6.1.4.1.231.2.10.20.622
The indicated fan became critical.
                         cabinetNotConfigured 1.3.6.1.4.1.231.2.10.20.623
The agent has detected a mismatch in the configuration of the server.
                         powerSupplyRemoved 1.3.6.1.4.1.231.2.10.20.624
One hot-replace power supply was removed.
                         powerSupplyAdded 1.3.6.1.4.1.231.2.10.20.625
One hot-replace power supply was added.
                         powerSupplyFailed 1.3.6.1.4.1.231.2.10.20.626
One hot-replace power supply failed.
                         powerSupplyOk 1.3.6.1.4.1.231.2.10.20.627
Power supply is working again.
                         powerSupplyStatusCritical 1.3.6.1.4.1.231.2.10.20.628
Power supply status has become critical.
                         fanOk 1.3.6.1.4.1.231.2.10.20.629
The indicated fan is OK again.
                         tempSensorBroken 1.3.6.1.4.1.231.2.10.20.630
The indicated temperature sensor is broken.
                         serverManagementDisabled 1.3.6.1.4.1.231.2.10.20.631
The server management BIOS is disabled.
                         trapAcFail 1.3.6.1.4.1.231.2.10.20.632
Mains failed in the specified cabinet. This can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this event.
                         trapDuplicateCabinetId 1.3.6.1.4.1.231.2.10.20.633
Two ore more cabinets (server or storage extension) have the same ID number. The system will not run properly.
                         trapEventLog 1.3.6.1.4.1.231.2.10.20.634
An error message was written into the systemboard's event/error log. This could have happened when an error occured before the agent was running or any error without a specific event message. See server management event/error log for detailed error description.
                         tempSensorOk 1.3.6.1.4.1.231.2.10.20.635
The indicated broken temperature sensor is OK again.
                         svCommunicationEstablished 1.3.6.1.4.1.231.2.10.20.636
Communication with the Server Management controller established again.
                         correctableMemErrorAddr 1.3.6.1.4.1.231.2.10.20.637
A correctable memory error at specified address was detected.
                         uncorrectableMemErrorAddr 1.3.6.1.4.1.231.2.10.20.638
An uncorrectable memory error at specified address was detected.
                         correctableMemErrorBank 1.3.6.1.4.1.231.2.10.20.639
A correctable memory error at specified bank was detected.
                         uncorrectableMemErrorBank 1.3.6.1.4.1.231.2.10.20.640
An uncorrectable memory error at specified bank was detected.
                         correctableMemErrorModule 1.3.6.1.4.1.231.2.10.20.641
A correctable memory error at specified module was detected.
                         uncorrectableMemErrorModule 1.3.6.1.4.1.231.2.10.20.642
An uncorrectable memory error at specified module was detected.
                         correctableMemError 1.3.6.1.4.1.231.2.10.20.643
A correctable memory error at unknown address was detected.
                         uncorrectableMemError 1.3.6.1.4.1.231.2.10.20.644
An uncorrectable memory error at unknown address was detected.
                         powerOffTimeReached 1.3.6.1.4.1.231.2.10.20.645
The power-off time is reached! System will shutdown in after delay.
                         frontDoorStatusChanged 1.3.6.1.4.1.231.2.10.20.646
The front door status has changed.
                         housingOpenStatusChanged 1.3.6.1.4.1.231.2.10.20.647
The housing open status has changed
                         sniScRedundantFanFailed 1.3.6.1.4.1.231.2.10.20.648
The indicated redundant fan failed.
                         sniScRedundantPowerSupplyFailed 1.3.6.1.4.1.231.2.10.20.649
One redundant hot-replace power supply failed.
                         sniScVoltageOk 1.3.6.1.4.1.231.2.10.20.650
Power supply voltage is within normal range again.
                         sniScVoltageTooLow 1.3.6.1.4.1.231.2.10.20.651
Power supply voltage is too low.
                         sniScVoltageTooHigh 1.3.6.1.4.1.231.2.10.20.652
Power supply voltage is too high.
                         sniScFanAdded 1.3.6.1.4.1.231.2.10.20.653
The indicated hot-plug fan was inserted.
                         sniScFanRemoved 1.3.6.1.4.1.231.2.10.20.654
The indicated hot-plug fan was removed.
                         sniScShutdownCancelled 1.3.6.1.4.1.231.2.10.20.655
This event will be sent if a pending server shutdown has been cancelled by the user.
                         sniScCpuSpeedChanged 1.3.6.1.4.1.231.2.10.20.656
The CPU clock frequency has been reduced because of a temperature problem.
                         sieScPowerOn 1.3.6.1.4.1.231.2.10.20.657
The server has been powered on.
                         sieScNoBootCpu 1.3.6.1.4.1.231.2.10.20.658
The system boot failed because no valid boot CPU has been found.
                         sieScPostError 1.3.6.1.4.1.231.2.10.20.659
This trap will be sent when the system boot fails, because the power on selftest (POST) has reported an error.
                         sieScSetupEntered 1.3.6.1.4.1.231.2.10.20.660
This trap will be sent when the bios setup has been entered.
                         sieScBootError 1.3.6.1.4.1.231.2.10.20.661
This trap will be sent when no bootable operating system can be found.
                         sieScBootWatchdogExpired 1.3.6.1.4.1.231.2.10.20.662
This trap will be sent when the boot watchdog expires.
                         sieScSoftwareWatchdogExpired 1.3.6.1.4.1.231.2.10.20.663
This trap will be sent when the software watchdog expires.
                         sieScUserAuthenticationFailure 1.3.6.1.4.1.231.2.10.20.664
This trap will be sent when an user authentication failure is detected via PPP, FTP, HTTP or telnet fails.
                         sieScDiagnosticBoot 1.3.6.1.4.1.231.2.10.20.665
This trap will be sent when a server is reset and diagnostic boot is enabled. The value in trapString specifies the primary channel i.e. the server name (from which the primary IP address may be derived).
                         sieScBootRetryCountZero 1.3.6.1.4.1.231.2.10.20.666
This trap will be sent when a boot retry counter gets zero on power up
                         sieScMessageLogFull 1.3.6.1.4.1.231.2.10.20.667
The System Event Log is full. No more messages can be logged. This trap will not occur on wrap-around log types.
                         memErrorModulePrefailure 1.3.6.1.4.1.231.2.10.20.668
A memory module is predicted to fail (prefailure).
                         memErrorModuleFailing 1.3.6.1.4.1.231.2.10.20.669
A memory module is failing.
                         memErrorModuleReplaced 1.3.6.1.4.1.231.2.10.20.670
A memory module had failed and was replaced by a hot-spare module.
                         sniScPowerSupplyRedundancyLost 1.3.6.1.4.1.231.2.10.20.671
Power supply redundancy no longer available.
                         sieScMessageLogWarning 1.3.6.1.4.1.231.2.10.20.672
The warning threshold for the number of System Event Log entries has been exceeded.
                         sieScCpuPrefailure 1.3.6.1.4.1.231.2.10.20.673
A CPU is predicted to fail (prefailure).
                         sieScPowerFail 1.3.6.1.4.1.231.2.10.20.674
DC power failed in the specified cabinet. This is the result of the system's power-good sensor monitoring. The system may stop when this condition occurs.
                         sieScBiosSelftestError 1.3.6.1.4.1.231.2.10.20.675
A critical error happend while BIOS selftest. This error needs to be acknowledged to clear the error condition.
                         sieScBiosSelftestWatchdogExpired 1.3.6.1.4.1.231.2.10.20.676
This trap will be sent when the BIOS selftest watchdog expires. This watchdog expires when the BIOS selftest cannot be finished in a certain time period.
                         sniScVoltageFailure 1.3.6.1.4.1.231.2.10.20.677
Power supply voltage is out of range.
                         sniScBatteryVoltagePrefailure 1.3.6.1.4.1.231.2.10.20.678
Battery is predicted to fail.
                         sieScSevereSystemError 1.3.6.1.4.1.231.2.10.20.679
The system was restarted after a severe problem. See server management message log (recovery log) for detailed information.