SLE-RED-MIB: View SNMP OID List / Download MIB

VENDOR: DASAN CO.,LTD.


 Home MIB: SLE-RED-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 sleRed 1.3.6.1.4.1.6296.101.22
This MIB contains information to support active/standby control redundancy.
       sleRedBase 1.3.6.1.4.1.6296.101.22.1
           sleRedInfo 1.3.6.1.4.1.6296.101.22.1.1
               sleRedActiveBoard 1.3.6.1.4.1.6296.101.22.1.1.1 sleredboardidtype read-only
Indication of the actual service board identifier. Regardless of redundancy mode, it has actual service board id.
               sleRedMode 1.3.6.1.4.1.6296.101.22.1.1.2 sleredmodetype read-only
If two SFUs are installed in the system, it works as redundant mode. Otherwise, it works as standalone mode.
               sleRedFaultCrashAction 1.3.6.1.4.1.6296.101.22.1.1.3 sleredfaultactiontype read-only
If any software module is crashed, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.
               sleRedFaultTimeoutAction 1.3.6.1.4.1.6296.101.22.1.1.4 sleredfaultactiontype read-only
If any software module doesn't respond for healthcheck messages for the certain time, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.
               sleRedFaultTimeout 1.3.6.1.4.1.6296.101.22.1.1.5 integer read-only
Healthcheck timeout. If a software module doesn't respond for the given time, it is regarded as a timed-out module. (Unit: second, default is '5')
               sleRedActivePrevState 1.3.6.1.4.1.6296.101.22.1.1.6 integer read-only
Previous state of active board. Enumeration: 'activeReady': 8, 'versionCheck': 11, 'configXfer': 5, 'standbyReset': 19, 'updateMac': 12, 'softwareSyncDone': 14, 'startupSync': 17, 'standbyReady': 18, 'disconnectStandby': 9, 'softwareSync': 13, 'singleActiveReady': 1, 'softwareXferDone': 4, 'standbyWait': 10, 'configXferDone': 6, 'versionReport': 2, 'stateXfer': 7, 'activeInit': 0, 'softwareXfer': 3, 'configSyncDone': 16, 'configSync': 15.
               sleRedActiveCurrState 1.3.6.1.4.1.6296.101.22.1.1.7 integer read-only
Current state of active board. Enumeration: 'activeReady': 8, 'versionCheck': 11, 'configXfer': 5, 'standbyReset': 19, 'updateMac': 12, 'softwareSyncDone': 14, 'startupSync': 17, 'standbyReady': 18, 'disconnectStandby': 9, 'softwareSync': 13, 'singleActiveReady': 1, 'softwareXferDone': 4, 'standbyWait': 10, 'configXferDone': 6, 'versionReport': 2, 'stateXfer': 7, 'activeInit': 0, 'softwareXfer': 3, 'configSyncDone': 16, 'configSync': 15.
           sleRedControl 1.3.6.1.4.1.6296.101.22.1.2
               sleRedControlRequest 1.3.6.1.4.1.6296.101.22.1.2.1 integer read-write
System commands related to control redundancy function. Enumeration: 'switchover': 2, 'setFaultMonitor': 3, 'reloadStandby': 1.
               sleRedControlStatus 1.3.6.1.4.1.6296.101.22.1.2.2 slecontrolstatustype read-only
The status of a user command.
               sleRedControlTimer 1.3.6.1.4.1.6296.101.22.1.2.3 gauge32 read-write
The maximum wait time for the manager for a long running user command.
               sleRedControlTimeStamp 1.3.6.1.4.1.6296.101.22.1.2.4 timeticks read-only
The time stamp of the last command (end of command).
               sleRedControlReqResult 1.3.6.1.4.1.6296.101.22.1.2.5 slecontrolrequestresulttype read-only
The result of the last user command.
               sleRedControlReloadOS 1.3.6.1.4.1.6296.101.22.1.2.6 sleredreloadostype read-write
A mate board is reloaded with the given os. If 'default' is given, the board is reloaded with 'default' OS.
               sleRedControlFaultCrashAction 1.3.6.1.4.1.6296.101.22.1.2.7 sleredfaultactiontype read-write
If any software module is crashed, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.
               sleRedControlFaultTimeoutAction 1.3.6.1.4.1.6296.101.22.1.2.8 sleredfaultactiontype read-write
If any software module doesn't respond for healthcheck messages for the certain time, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.
               sleRedControlFaultTimeout 1.3.6.1.4.1.6296.101.22.1.2.9 integer read-write
Healthcheck timeout. If a software module doesn't respond for the given time, it is regarded as a timed-out module. (Unit: second, default is '5')
           sleRedNotification 1.3.6.1.4.1.6296.101.22.1.3
               sleRedMateReloadRequested 1.3.6.1.4.1.6296.101.22.1.3.1
A new active SFU indication
               sleRedSwitchoverRequested 1.3.6.1.4.1.6296.101.22.1.3.2
The system redundancy mode has been changed. A standby board is pluged out or in.
               sleRedFaultMonitorChanged 1.3.6.1.4.1.6296.101.22.1.3.3
Fault monitor configuration has been changed.
       sleRedGroup 1.3.6.1.4.1.6296.101.22.2
Description.
       sleRedNotificationGroup 1.3.6.1.4.1.6296.101.22.3
Description.