SLE-MPLS-TP-LPS-MIB: View SNMP OID List / Download MIB

VENDOR: DASAN CO.,LTD.


 Home MIB: SLE-MPLS-TP-LPS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 sleMpls 1.3.6.1.4.1.6296.101.16
SLE MplsTp.
       sleMplsTpLps 1.3.6.1.4.1.6296.101.16.18
This management information module supports the configuration and management of MplsTp TP linear protection groups.
             sleMplsTpLpsCfg 1.3.6.1.4.1.6296.101.16.18.1
                 sleMplsTpLpsCfgInfoTable 1.3.6.1.4.1.6296.101.16.18.1.1 read-only
This table lists the sleMplsTp linear protection groups that have been configured on the system.
                     sleMplsTpLpsCfgInfoEntry 1.3.6.1.4.1.6296.101.16.18.1.1.1 read-only
A conceptual row in the sleMplsTpLpsCfgInfoTable.
                         sleMplsTpLpsCfgInfoGroupIndex 1.3.6.1.4.1.6296.101.16.18.1.1.1.1 unsigned32 read-only
Index for the conceptual row identifying a protection group.
                         sleMplsTpLpsCfgInfoGroupName 1.3.6.1.4.1.6296.101.16.18.1.1.1.2 octet string read-only
Textual name represents the sleMplsTp tp protection group. Each Protection Group is identified by a unique protection group name.
                         sleMplsTpLpsCfgInfoMode 1.3.6.1.4.1.6296.101.16.18.1.1.1.3 integer read-only
The architectural mode of the Protection group. This can either be 1+1, 1:1, 1:n. 1+1 In the 1+1 protection scheme, a fully dedicated protection entity is allocated. Data traffic is copied and fed at the source to both the working and the protection entities. The traffic on the working and the protection entities is transmitted simultaneously to the sink of the protection domain, where selection between the working and protection entities is performed 1:1 In the 1:1 scheme, a protection path is allocated to protect against a defect, failure, or a degradation in a working path. In normal conditions, data traffic is transmitted over the working entity, while the protection entity functions in the idle state. If there is a defect on the working entity or a specific administrative request, traffic is switched to the protection entity. 1:n In case of 1:n linear protection, one protection entity is allocated to protect n working entities. The protection entity might not have sufficient resources to protect all the working entities that may be affected by fault conditions at a specific time. In this case, in order to guaranteed protection, the protection entity should support enough capacity and bandwidth to protect any of the n working entities. Enumeration: 'oneColonN': 3, 'onePlusOne': 1, 'oneColonOne': 2.
                         sleMplsTpLpsCfgInfoProtectionScheme 1.3.6.1.4.1.6296.101.16.18.1.1.1.4 integer read-only
The object represents the operational scheme of protection switching group. The protection scheme may either be unidirectional or bidirectional. bidirectional In bidirectional protection scheme, both the directions will be switched simultaneously even if the fault applies to only one direction of the path. unidirectional In unidirectional protection scheme protection switching will be performed independently for each direction of a bidirectional transport path This object may not be modified if the associated sleMplsTpLpsCfgRowStatus object is equal to active(1). Enumeration: 'bidirectional': 1, 'unidirectional': 2.
                         sleMplsTpLpsCfgInfoRevertive 1.3.6.1.4.1.6296.101.16.18.1.1.1.5 integer read-only
This object represents the reversion mode of the Linear Protection Switching group. The reversion mode of protection mechanism may be either revertive or non-revertive. In non-revertive mode, after a service has been recovered, traffic will be forwarded on the recovery path revertive In revertive mode, after a service has been recovered, traffic will be redirected back onto the original working path. Enumeration: 'revertive': 2, 'nonrevertive': 1.
                         sleMplsTpLpsCfgInfoWtr 1.3.6.1.4.1.6296.101.16.18.1.1.1.6 unsigned32 read-only
This object hold the Wait To Restore timer value in seconds. The WTR timer is used to delay reversion of PSC state to Normal state when recovering from a failure condition on the working path when the protection domain is configured for revertive behavior This object may not be modified if the associated sleMplsTpLpsCfgRowStatus object is equal to active(1).
                         sleMplsTpLpsCfgInfoContinualTxInterval 1.3.6.1.4.1.6296.101.16.18.1.1.1.7 unsigned32 read-only
The Continual Tx Time in Seconds. Represents the time interval to send the continual LPS packet to the other end based on the current state.
                         sleMplsTpLpsCfgInfoRapidTxInterval 1.3.6.1.4.1.6296.101.16.18.1.1.1.8 unsigned32 read-only
The Rapid Tx interval in micro-Seconds. Represents the time interval to send the LPS packet to the other end, when there is a change in state of Linear Protection domain due to local input. The default value is 3.3 milli-seconds which is 3300 micro-seconds
                         sleMplsTpLpsCfgInfoSwitchOver 1.3.6.1.4.1.6296.101.16.18.1.1.1.9 integer read-only
this object used for switch the traffic to the back up path. Enumeration: 'forced': 1, 'none': 0, 'manual': 2.
                         sleMplsTpLpsCfgInfoLockOut 1.3.6.1.4.1.6296.101.16.18.1.1.1.10 integer read-only
this is object is used for preventing the swith traffic by the protection path. Enumeration: 'enable': 1, 'disable': 2.
                         sleMplsTpLpsCfgInfoHoldOffTimer 1.3.6.1.4.1.6296.101.16.18.1.1.1.11 unsigned32 read-only
this object used for show the hold off timer.
                         sleMplsTpLpsCfgInfoActivePath 1.3.6.1.4.1.6296.101.16.18.1.1.1.12 integer read-only
This object say which path is Active . Enumeration: 'backup': 2, 'primary': 1.
                         sleMplsTpLpsCfgInfoOperationState 1.3.6.1.4.1.6296.101.16.18.1.1.1.13 integer read-only
this object says Operational Status of LPS. The LPS is between PE to PE. Enumeration: 'down': 0, 'up': 1.
                         sleMplsTpLpsCfgInfoEventStatus 1.3.6.1.4.1.6296.101.16.18.1.1.1.14 integer read-only
This is object says EVENT Status of LPS protection . Enumeration: 'remoteRrReqProtec': 26, 'remoteSfWork': 16, 'localClrEvent': 11, 'remoteLock': 12, 'remoteManual': 14, 'localClearSdWorking': 32, 'localClrSfProtection': 9, 'remoteNotRevert': 19, 'remoteExesProtect': 24, 'localExercise': 33, 'localManual': 4, 'localWtr': 7, 'remoteRrReqWork': 25, 'normal': 1, 'remoteSdWork': 21, 'noRequest': 20, 'protection': 2, 'remoteForce': 13, 'remoteWtr': 17, 'localForce': 3, 'remoteNoReqProtection': 28, 'remoteNoReq': 18, 'localSgfWorking': 6, 'localSgfProtection': 5, 'localLock': 8, 'remoteSfProtect': 15, 'localClearSdProtection': 30, 'localClrSfWorking': 10, 'remoteSdProtection': 22, 'remoteExesWork': 23, 'localSdProtection': 29, 'localSdWorking': 31, 'remoteNoReqWork': 27.
                 sleMplsTpLpsCfgControl 1.3.6.1.4.1.6296.101.16.18.1.2
                     sleMplsTpLpsCfgControlRequest 1.3.6.1.4.1.6296.101.16.18.1.2.1 integer read-write
the configuration commands, and user can configure functions via setting this entry as proper value. Enumeration: 'unsetSleMplsTpLpsCfgControlSwitchover': 13, 'createSleMplsTpLpsCfgEntry': 1, 'setSleMplsLpsTpCfgControlWaitToRestoreset': 6, 'unsetSleMplsTpLpsCfgControlRapidTxInterval': 11, 'deleteSleMplsTpLpsCfgEntry': 2, 'setSleMplsTpLpsCfgControlLockOut': 14, 'setSleMplsTpLpsCfgControProtectionScheme': 3, 'unsetSleMplsTpLpsCfgControlWaitToRestoreset': 7, 'setSleMplsLpsTpCfgControlSwitchover': 12, 'unsetSleMplsTpLpsCfgControlContinualTxInterval': 9, 'setSleMplsLpsTpCfgControlRevertive': 5, 'unsetSleMplsTpLpsCfgControProtectionScheme': 4, 'setSleMplsLpsTpCfgControlRapidTxInterval': 10, 'setSleMplsLpsTpCfgControlContinualTxInterval': 8, 'setSleMplsTpLpsCfgControlHoldOffTimer': 16, 'unsetSleMplsTpLpsTpCfgControlLockOut': 15, 'unSetSleMplsTpLpsCfgControlHoldOffTimer': 17.
                     sleMplsTpLpsCfgControlStatus 1.3.6.1.4.1.6296.101.16.18.1.2.2 slecontrolstatustype read-only
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
                     sleMplsTpLpsCfgControlTimer 1.3.6.1.4.1.6296.101.16.18.1.2.3 gauge32 read-write
the wait-time until setRequest end. In case of short-time command, this value is 0
                     sleMplsTpLpsCfgControlTimeStamp 1.3.6.1.4.1.6296.101.16.18.1.2.4 timeticks read-only
the time stamp of the last command. (don.t care)
                     sleMplsTpLpsCfgControlReqResult 1.3.6.1.4.1.6296.101.16.18.1.2.5 slecontrolrequestresulttype read-only
Result of the last command.
                     sleMplsTpLpsCfgControlGroupName 1.3.6.1.4.1.6296.101.16.18.1.2.6 octet string read-write
Textual name represents the sleMplsTp tp protection group. Each Protection Group is identified by a unique protection group name.
                     sleMplsTpLpsCfgControlMode 1.3.6.1.4.1.6296.101.16.18.1.2.7 integer read-write
The architectural mode of the Protection group. This can either be 1+1, 1:1, 1:n. 1+1 In the 1+1 protection scheme, a fully dedicated protection entity is allocated. Data traffic is copied and fed at the source to both the working and the protection entities. The traffic on the working and the protection entities is transmitted simultaneously to the sink of the protection domain, where selection between the working and protection entities is performed 1:1 In the 1:1 scheme, a protection path is allocated to protect against a defect, failure, or a degradation in a working path. In normal conditions, data traffic is transmitted over the working entity, while the protection entity functions in the idle state. If there is a defect on the working entity or a specific administrative request, traffic is switched to the protection entity. 1:n In case of 1:n linear protection, one protection entity is allocated to protect n working entities. The protection entity might not have sufficient resources to protect all the working entities that may be affected by fault conditions at a specific time. In this case, in order to guaranteed protection, the protection entity should support enough capacity and bandwidth to protect any of the n working entities. Enumeration: 'oneColonN': 3, 'onePlusOne': 1, 'oneColonOne': 2.
                     sleMplsTpLpsCfgControlProtectionScheme 1.3.6.1.4.1.6296.101.16.18.1.2.8 integer read-write
The object represents the operational scheme of protection switching group. The protection scheme may either be unidirectional or bidirectional. bidirectional In bidirectional protection scheme, both the directions will be switched simultaneously even if the fault applies to only one direction of the path. unidirectional In unidirectional protection scheme protection switching will be performed independently for each direction of a bidirectional transport path This object may not be modified if the associated sleMplsTpLpsCfgControlRowStatus object is equal to active(1). Enumeration: 'bidirectional': 1, 'unidirectional': 2.
                     sleMplsTpLpsCfgControlRevertive 1.3.6.1.4.1.6296.101.16.18.1.2.9 integer read-write
This object represents the reversion mode of the Linear Protection Switching group. The reversion mode of protection mechanism may be either revertive or non-revertive. nonrevertive In non-revertive mode, after a service has been recovered, traffic will be forwarded on the recovery path revertive In revertive mode, after a service has been recovered, traffic will be redirected back onto the original working path. Enumeration: 'revertive': 2, 'nonrevertive': 1.
                     sleMplsTpLpsCfgControlWtr 1.3.6.1.4.1.6296.101.16.18.1.2.10 unsigned32 read-write
This object hold the Wait To Restore timer value in seconds. The WTR timer is used to delay reversion of PSC state to Normal state when recovering from a failure condition on the working path when the protection domain is configured for revertive behavior This object may not be modified if the associated sleMplsTpLpsCfgControlRowStatus object is equal to active(1).
                     sleMplsTpLpsCfgControlContinualTxInterval 1.3.6.1.4.1.6296.101.16.18.1.2.11 unsigned32 read-write
The Continual Tx Time in Seconds. Represents the time interval to send the continual LPS packet to the other end based on the current state.
                     sleMplsTpLpsCfgControlRapidTxInterval 1.3.6.1.4.1.6296.101.16.18.1.2.12 unsigned32 read-write
The Rapid Tx interval in micro-Seconds. Represents the time interval to send the LPS packet to the other end, when there is a change in state of Linear Protection domain due to local input. The default value is 3.3 milli-seconds which is 3300 micro-seconds
                     sleMplsTpLpsCfgControlswitchOver 1.3.6.1.4.1.6296.101.16.18.1.2.13 integer read-write
this object used for switch the traffic to the back up path. Enumeration: 'manual': 2, 'force': 1.
                     sleMplsTpLpsCfgControlLockOut 1.3.6.1.4.1.6296.101.16.18.1.2.14 integer read-write
this is object is used for preventing the swith traffic by the protection path. Enumeration: 'enable': 1, 'disable': 0.
                     sleMplsTpLpsCfgControlHoldOffTimer 1.3.6.1.4.1.6296.101.16.18.1.2.15 unsigned32 read-write
This object is used to set the holdofftimer
             sleMplsTpLpsMeCfg 1.3.6.1.4.1.6296.101.16.18.2
                 sleMplsTpLpsMeCfgInfoTable 1.3.6.1.4.1.6296.101.16.18.2.1 no-access
This table lists Maintenance Association that have been configured in Protection groups.
                     sleMplsTpLpsMeCfgInfoEntry 1.3.6.1.4.1.6296.101.16.18.2.1.1 no-access
A conceptual row in the sleMplsTpLpsMeCfgInfoTable.
                         sleMplsTpLpsMeCfgInfoMegIndex 1.3.6.1.4.1.6296.101.16.18.2.1.1.1 unsigned32 no-access
Uniquely identifies a maintenance entity index within a MEG.
                         sleMplsTpLpsMeCfgInfoMeIndex 1.3.6.1.4.1.6296.101.16.18.2.1.1.2 unsigned32 no-access
This object denotes the ME name, each Maintenance Entity has unique name within MEG.
                         sleMplsTpLpsMeCfgInfoMPId 1.3.6.1.4.1.6296.101.16.18.2.1.1.3 unsigned32 no-access
Indicates the maintenance point index, used to create multiple MEPs in a node of single ME. The value of this object can be MEP index or MIP index. Managers should obtain new values for row creation in this table by reading mplsOamIdMeMpIndexNext.
                         sleMplsTpLspMeCfgInfoGroupIndex 1.3.6.1.4.1.6296.101.16.18.2.1.1.4 unsigned32 read-only
Textual name represents the sleMplsTp tp protection group. Each Protection Group is identified by a unique protection group name.
                         sleMplsTpLpsMeCfgInfoState 1.3.6.1.4.1.6296.101.16.18.2.1.1.5 integer read-write
This object represents the operational state of the ME as either primary or backup Enumeration: 'backup': 2, 'primary': 1.
                 sleMplsTpLpsMeCfgControl 1.3.6.1.4.1.6296.101.16.18.2.2
                     sleMplsTpLpsMeCfgControlRequest 1.3.6.1.4.1.6296.101.16.18.2.2.1 integer read-write
the configuration commands, and user can configure functions via setting this entry as proper value. Enumeration: 'createSleMplsTpLpsMeConfigEntry': 1, 'deleteSleMplsTpLpsMeConfigEntry': 2.
                     sleMplsTpLpsMeCfgControlStatus 1.3.6.1.4.1.6296.101.16.18.2.2.2 slecontrolstatustype read-only
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
                     sleMplsTpLpsMeCfgControlTimer 1.3.6.1.4.1.6296.101.16.18.2.2.3 gauge32 read-write
the wait-time until setRequest end. In case of short-time command, this value is 0
                     sleMplsTpLpsMeCfgControlTimeStamp 1.3.6.1.4.1.6296.101.16.18.2.2.4 timeticks read-only
the time stamp of the last command. (don.t care)
                     sleMplsTpLpsMeCfgControlReqResult 1.3.6.1.4.1.6296.101.16.18.2.2.5 slecontrolrequestresulttype read-only
Result of the last command.
                     sleMplsTpLpsMeCfgControlMegName 1.3.6.1.4.1.6296.101.16.18.2.2.6 octet string read-write
Uniquely identifies a maintenance entity index within a MEG
                     sleMplsTpLpsMeCfgControlMeName 1.3.6.1.4.1.6296.101.16.18.2.2.7 octet string read-write
This object denotes the ME name, each Maintenance Entity has unique name within MEG.
                     sleMplsTpLpsMeCfgControlMpId 1.3.6.1.4.1.6296.101.16.18.2.2.8 unsigned32 read-write
                     sleMplsTpLpsMeCfgControlGroupName 1.3.6.1.4.1.6296.101.16.18.2.2.9 octet string read-write
This object holds the Protection group index wherein this ME included in. If this ME is not part of a protection group this value is set to 0.
                     sleMplsTpLpsMeCfgControlState 1.3.6.1.4.1.6296.101.16.18.2.2.10 integer read-write
This object represents the operational state of the ME as either primary or backup Enumeration: 'backup': 2, 'primary': 1.