SLE-MPLS-TP-LPS-MIB: View SNMP OID List / Download MIB
VENDOR: DASAN CO.,LTD.
Home | MIB: SLE-MPLS-TP-LPS-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
sleMpls | 1.3.6.1.4.1.6296.101.16 |
SLE MplsTp. |
||
sleMplsTpLps | 1.3.6.1.4.1.6296.101.16.18 |
This management information module supports the configuration and management of MplsTp TP linear protection groups. |
||
sleMplsTpLpsCfg | 1.3.6.1.4.1.6296.101.16.18.1 | |||
sleMplsTpLpsCfgInfoTable | 1.3.6.1.4.1.6296.101.16.18.1.1 | read-only |
This table lists the sleMplsTp linear protection groups that have been configured on the system. |
|
1.3.6.1.4.1.6296.101.16.18.1.1.1 | read-only |
A conceptual row in the sleMplsTpLpsCfgInfoTable. |
||
sleMplsTpLpsCfgInfoGroupIndex | 1.3.6.1.4.1.6296.101.16.18.1.1.1.1 | unsigned32 | read-only |
Index for the conceptual row identifying a protection group. |
sleMplsTpLpsCfgInfoGroupName | 1.3.6.1.4.1.6296.101.16.18.1.1.1.2 | octet string | read-only |
Textual name represents the sleMplsTp tp protection group. Each Protection Group is identified by a unique protection group name. |
sleMplsTpLpsCfgInfoMode | 1.3.6.1.4.1.6296.101.16.18.1.1.1.3 | integer | read-only |
The architectural mode of the Protection group. This can either be 1+1, 1:1, 1:n. 1+1 In the 1+1 protection scheme, a fully dedicated protection entity is allocated. Data traffic is copied and fed at the source to both the working and the protection entities. The traffic on the working and the protection entities is transmitted simultaneously to the sink of the protection domain, where selection between the working and protection entities is performed 1:1 In the 1:1 scheme, a protection path is allocated to protect against a defect, failure, or a degradation in a working path. In normal conditions, data traffic is transmitted over the working entity, while the protection entity functions in the idle state. If there is a defect on the working entity or a specific administrative request, traffic is switched to the protection entity. 1:n In case of 1:n linear protection, one protection entity is allocated to protect n working entities. The protection entity might not have sufficient resources to protect all the working entities that may be affected by fault conditions at a specific time. In this case, in order to guaranteed protection, the protection entity should support enough capacity and bandwidth to protect any of the n working entities. Enumeration: 'oneColonN': 3, 'onePlusOne': 1, 'oneColonOne': 2. |
sleMplsTpLpsCfgInfoProtectionScheme | 1.3.6.1.4.1.6296.101.16.18.1.1.1.4 | integer | read-only |
The object represents the operational scheme of protection switching group. The protection scheme may either be unidirectional or bidirectional. bidirectional In bidirectional protection scheme, both the directions will be switched simultaneously even if the fault applies to only one direction of the path. unidirectional In unidirectional protection scheme protection switching will be performed independently for each direction of a bidirectional transport path This object may not be modified if the associated sleMplsTpLpsCfgRowStatus object is equal to active(1). Enumeration: 'bidirectional': 1, 'unidirectional': 2. |
sleMplsTpLpsCfgInfoRevertive | 1.3.6.1.4.1.6296.101.16.18.1.1.1.5 | integer | read-only |
This object represents the reversion mode of the Linear Protection Switching group. The reversion mode of protection mechanism may be either revertive or non-revertive. In non-revertive mode, after a service has been recovered, traffic will be forwarded on the recovery path revertive In revertive mode, after a service has been recovered, traffic will be redirected back onto the original working path. Enumeration: 'revertive': 2, 'nonrevertive': 1. |
sleMplsTpLpsCfgInfoWtr | 1.3.6.1.4.1.6296.101.16.18.1.1.1.6 | unsigned32 | read-only |
This object hold the Wait To Restore timer value in seconds. The WTR timer is used to delay reversion of PSC state to Normal state when recovering from a failure condition on the working path when the protection domain is configured for revertive behavior This object may not be modified if the associated sleMplsTpLpsCfgRowStatus object is equal to active(1). |
sleMplsTpLpsCfgInfoContinualTxInterval | 1.3.6.1.4.1.6296.101.16.18.1.1.1.7 | unsigned32 | read-only |
The Continual Tx Time in Seconds. Represents the time interval to send the continual LPS packet to the other end based on the current state. |
sleMplsTpLpsCfgInfoRapidTxInterval | 1.3.6.1.4.1.6296.101.16.18.1.1.1.8 | unsigned32 | read-only |
The Rapid Tx interval in micro-Seconds. Represents the time interval to send the LPS packet to the other end, when there is a change in state of Linear Protection domain due to local input. The default value is 3.3 milli-seconds which is 3300 micro-seconds |
sleMplsTpLpsCfgInfoSwitchOver | 1.3.6.1.4.1.6296.101.16.18.1.1.1.9 | integer | read-only |
this object used for switch the traffic to the back up path. Enumeration: 'forced': 1, 'none': 0, 'manual': 2. |
sleMplsTpLpsCfgInfoLockOut | 1.3.6.1.4.1.6296.101.16.18.1.1.1.10 | integer | read-only |
this is object is used for preventing the swith traffic by the protection path. Enumeration: 'enable': 1, 'disable': 2. |
sleMplsTpLpsCfgInfoHoldOffTimer | 1.3.6.1.4.1.6296.101.16.18.1.1.1.11 | unsigned32 | read-only |
this object used for show the hold off timer. |
sleMplsTpLpsCfgInfoActivePath | 1.3.6.1.4.1.6296.101.16.18.1.1.1.12 | integer | read-only |
This object say which path is Active . Enumeration: 'backup': 2, 'primary': 1. |
sleMplsTpLpsCfgInfoOperationState | 1.3.6.1.4.1.6296.101.16.18.1.1.1.13 | integer | read-only |
this object says Operational Status of LPS. The LPS is between PE to PE. Enumeration: 'down': 0, 'up': 1. |
sleMplsTpLpsCfgInfoEventStatus | 1.3.6.1.4.1.6296.101.16.18.1.1.1.14 | integer | read-only |
This is object says EVENT Status of LPS protection . Enumeration: 'remoteRrReqProtec': 26, 'remoteSfWork': 16, 'localClrEvent': 11, 'remoteLock': 12, 'remoteManual': 14, 'localClearSdWorking': 32, 'localClrSfProtection': 9, 'remoteNotRevert': 19, 'remoteExesProtect': 24, 'localExercise': 33, 'localManual': 4, 'localWtr': 7, 'remoteRrReqWork': 25, 'normal': 1, 'remoteSdWork': 21, 'noRequest': 20, 'protection': 2, 'remoteForce': 13, 'remoteWtr': 17, 'localForce': 3, 'remoteNoReqProtection': 28, 'remoteNoReq': 18, 'localSgfWorking': 6, 'localSgfProtection': 5, 'localLock': 8, 'remoteSfProtect': 15, 'localClearSdProtection': 30, 'localClrSfWorking': 10, 'remoteSdProtection': 22, 'remoteExesWork': 23, 'localSdProtection': 29, 'localSdWorking': 31, 'remoteNoReqWork': 27. |
sleMplsTpLpsCfgControl | 1.3.6.1.4.1.6296.101.16.18.1.2 | |||
sleMplsTpLpsCfgControlRequest | 1.3.6.1.4.1.6296.101.16.18.1.2.1 | integer | read-write |
the configuration commands, and user can configure functions via setting this entry as proper value. Enumeration: 'unsetSleMplsTpLpsCfgControlSwitchover': 13, 'createSleMplsTpLpsCfgEntry': 1, 'setSleMplsLpsTpCfgControlWaitToRestoreset': 6, 'unsetSleMplsTpLpsCfgControlRapidTxInterval': 11, 'deleteSleMplsTpLpsCfgEntry': 2, 'setSleMplsTpLpsCfgControlLockOut': 14, 'setSleMplsTpLpsCfgControProtectionScheme': 3, 'unsetSleMplsTpLpsCfgControlWaitToRestoreset': 7, 'setSleMplsLpsTpCfgControlSwitchover': 12, 'unsetSleMplsTpLpsCfgControlContinualTxInterval': 9, 'setSleMplsLpsTpCfgControlRevertive': 5, 'unsetSleMplsTpLpsCfgControProtectionScheme': 4, 'setSleMplsLpsTpCfgControlRapidTxInterval': 10, 'setSleMplsLpsTpCfgControlContinualTxInterval': 8, 'setSleMplsTpLpsCfgControlHoldOffTimer': 16, 'unsetSleMplsTpLpsTpCfgControlLockOut': 15, 'unSetSleMplsTpLpsCfgControlHoldOffTimer': 17. |
sleMplsTpLpsCfgControlStatus | 1.3.6.1.4.1.6296.101.16.18.1.2.2 | slecontrolstatustype | read-only |
status of user command. User have to check this value as .busy. or .idle. before do setRequest. |
sleMplsTpLpsCfgControlTimer | 1.3.6.1.4.1.6296.101.16.18.1.2.3 | gauge32 | read-write |
the wait-time until setRequest end. In case of short-time command, this value is 0 |
sleMplsTpLpsCfgControlTimeStamp | 1.3.6.1.4.1.6296.101.16.18.1.2.4 | timeticks | read-only |
the time stamp of the last command. (don.t care) |
sleMplsTpLpsCfgControlReqResult | 1.3.6.1.4.1.6296.101.16.18.1.2.5 | slecontrolrequestresulttype | read-only |
Result of the last command. |
sleMplsTpLpsCfgControlGroupName | 1.3.6.1.4.1.6296.101.16.18.1.2.6 | octet string | read-write |
Textual name represents the sleMplsTp tp protection group. Each Protection Group is identified by a unique protection group name. |
sleMplsTpLpsCfgControlMode | 1.3.6.1.4.1.6296.101.16.18.1.2.7 | integer | read-write |
The architectural mode of the Protection group. This can either be 1+1, 1:1, 1:n. 1+1 In the 1+1 protection scheme, a fully dedicated protection entity is allocated. Data traffic is copied and fed at the source to both the working and the protection entities. The traffic on the working and the protection entities is transmitted simultaneously to the sink of the protection domain, where selection between the working and protection entities is performed 1:1 In the 1:1 scheme, a protection path is allocated to protect against a defect, failure, or a degradation in a working path. In normal conditions, data traffic is transmitted over the working entity, while the protection entity functions in the idle state. If there is a defect on the working entity or a specific administrative request, traffic is switched to the protection entity. 1:n In case of 1:n linear protection, one protection entity is allocated to protect n working entities. The protection entity might not have sufficient resources to protect all the working entities that may be affected by fault conditions at a specific time. In this case, in order to guaranteed protection, the protection entity should support enough capacity and bandwidth to protect any of the n working entities. Enumeration: 'oneColonN': 3, 'onePlusOne': 1, 'oneColonOne': 2. |
sleMplsTpLpsCfgControlProtectionScheme | 1.3.6.1.4.1.6296.101.16.18.1.2.8 | integer | read-write |
The object represents the operational scheme of protection switching group. The protection scheme may either be unidirectional or bidirectional. bidirectional In bidirectional protection scheme, both the directions will be switched simultaneously even if the fault applies to only one direction of the path. unidirectional In unidirectional protection scheme protection switching will be performed independently for each direction of a bidirectional transport path This object may not be modified if the associated sleMplsTpLpsCfgControlRowStatus object is equal to active(1). Enumeration: 'bidirectional': 1, 'unidirectional': 2. |
sleMplsTpLpsCfgControlRevertive | 1.3.6.1.4.1.6296.101.16.18.1.2.9 | integer | read-write |
This object represents the reversion mode of the Linear Protection Switching group. The reversion mode of protection mechanism may be either revertive or non-revertive. nonrevertive In non-revertive mode, after a service has been recovered, traffic will be forwarded on the recovery path revertive In revertive mode, after a service has been recovered, traffic will be redirected back onto the original working path. Enumeration: 'revertive': 2, 'nonrevertive': 1. |
sleMplsTpLpsCfgControlWtr | 1.3.6.1.4.1.6296.101.16.18.1.2.10 | unsigned32 | read-write |
This object hold the Wait To Restore timer value in seconds. The WTR timer is used to delay reversion of PSC state to Normal state when recovering from a failure condition on the working path when the protection domain is configured for revertive behavior This object may not be modified if the associated sleMplsTpLpsCfgControlRowStatus object is equal to active(1). |
sleMplsTpLpsCfgControlContinualTxInterval | 1.3.6.1.4.1.6296.101.16.18.1.2.11 | unsigned32 | read-write |
The Continual Tx Time in Seconds. Represents the time interval to send the continual LPS packet to the other end based on the current state. |
sleMplsTpLpsCfgControlRapidTxInterval | 1.3.6.1.4.1.6296.101.16.18.1.2.12 | unsigned32 | read-write |
The Rapid Tx interval in micro-Seconds. Represents the time interval to send the LPS packet to the other end, when there is a change in state of Linear Protection domain due to local input. The default value is 3.3 milli-seconds which is 3300 micro-seconds |
sleMplsTpLpsCfgControlswitchOver | 1.3.6.1.4.1.6296.101.16.18.1.2.13 | integer | read-write |
this object used for switch the traffic to the back up path. Enumeration: 'manual': 2, 'force': 1. |
sleMplsTpLpsCfgControlLockOut | 1.3.6.1.4.1.6296.101.16.18.1.2.14 | integer | read-write |
this is object is used for preventing the swith traffic by the protection path. Enumeration: 'enable': 1, 'disable': 0. |
sleMplsTpLpsCfgControlHoldOffTimer | 1.3.6.1.4.1.6296.101.16.18.1.2.15 | unsigned32 | read-write |
This object is used to set the holdofftimer |
sleMplsTpLpsMeCfg | 1.3.6.1.4.1.6296.101.16.18.2 | |||
sleMplsTpLpsMeCfgInfoTable | 1.3.6.1.4.1.6296.101.16.18.2.1 | no-access |
This table lists Maintenance Association that have been configured in Protection groups. |
|
1.3.6.1.4.1.6296.101.16.18.2.1.1 | no-access |
A conceptual row in the sleMplsTpLpsMeCfgInfoTable. |
||
sleMplsTpLpsMeCfgInfoMegIndex | 1.3.6.1.4.1.6296.101.16.18.2.1.1.1 | unsigned32 | no-access |
Uniquely identifies a maintenance entity index within a MEG. |
sleMplsTpLpsMeCfgInfoMeIndex | 1.3.6.1.4.1.6296.101.16.18.2.1.1.2 | unsigned32 | no-access |
This object denotes the ME name, each Maintenance Entity has unique name within MEG. |
sleMplsTpLpsMeCfgInfoMPId | 1.3.6.1.4.1.6296.101.16.18.2.1.1.3 | unsigned32 | no-access |
Indicates the maintenance point index, used to create multiple MEPs in a node of single ME. The value of this object can be MEP index or MIP index. Managers should obtain new values for row creation in this table by reading mplsOamIdMeMpIndexNext. |
sleMplsTpLspMeCfgInfoGroupIndex | 1.3.6.1.4.1.6296.101.16.18.2.1.1.4 | unsigned32 | read-only |
Textual name represents the sleMplsTp tp protection group. Each Protection Group is identified by a unique protection group name. |
sleMplsTpLpsMeCfgInfoState | 1.3.6.1.4.1.6296.101.16.18.2.1.1.5 | integer | read-write |
This object represents the operational state of the ME as either primary or backup Enumeration: 'backup': 2, 'primary': 1. |
sleMplsTpLpsMeCfgControl | 1.3.6.1.4.1.6296.101.16.18.2.2 | |||
sleMplsTpLpsMeCfgControlRequest | 1.3.6.1.4.1.6296.101.16.18.2.2.1 | integer | read-write |
the configuration commands, and user can configure functions via setting this entry as proper value. Enumeration: 'createSleMplsTpLpsMeConfigEntry': 1, 'deleteSleMplsTpLpsMeConfigEntry': 2. |
sleMplsTpLpsMeCfgControlStatus | 1.3.6.1.4.1.6296.101.16.18.2.2.2 | slecontrolstatustype | read-only |
status of user command. User have to check this value as .busy. or .idle. before do setRequest. |
sleMplsTpLpsMeCfgControlTimer | 1.3.6.1.4.1.6296.101.16.18.2.2.3 | gauge32 | read-write |
the wait-time until setRequest end. In case of short-time command, this value is 0 |
sleMplsTpLpsMeCfgControlTimeStamp | 1.3.6.1.4.1.6296.101.16.18.2.2.4 | timeticks | read-only |
the time stamp of the last command. (don.t care) |
sleMplsTpLpsMeCfgControlReqResult | 1.3.6.1.4.1.6296.101.16.18.2.2.5 | slecontrolrequestresulttype | read-only |
Result of the last command. |
sleMplsTpLpsMeCfgControlMegName | 1.3.6.1.4.1.6296.101.16.18.2.2.6 | octet string | read-write |
Uniquely identifies a maintenance entity index within a MEG |
sleMplsTpLpsMeCfgControlMeName | 1.3.6.1.4.1.6296.101.16.18.2.2.7 | octet string | read-write |
This object denotes the ME name, each Maintenance Entity has unique name within MEG. |
sleMplsTpLpsMeCfgControlMpId | 1.3.6.1.4.1.6296.101.16.18.2.2.8 | unsigned32 | read-write |
|
sleMplsTpLpsMeCfgControlGroupName | 1.3.6.1.4.1.6296.101.16.18.2.2.9 | octet string | read-write |
This object holds the Protection group index wherein this ME included in. If this ME is not part of a protection group this value is set to 0. |
sleMplsTpLpsMeCfgControlState | 1.3.6.1.4.1.6296.101.16.18.2.2.10 | integer | read-write |
This object represents the operational state of the ME as either primary or backup Enumeration: 'backup': 2, 'primary': 1. |