SLE-AM-MIB: View SNMP OID List / Download MIB
VENDOR: DASAN CO.,LTD.
Home | MIB: SLE-AM-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
sleAlarmMgr | 1.3.6.1.4.1.6296.101.15 |
This MIB contains all needed informations about Alarm Manager. |
||
sleAMAlarmTrapNeId | 1.3.6.1.4.1.6296.101.15.1 | octet string | read-only |
use for NE idendification when alarm(or event) trap system MAC address |
sleAMConfigBase | 1.3.6.1.4.1.6296.101.15.2 | |||
sleAMConfigTable | 1.3.6.1.4.1.6296.101.15.2.1 | no-access |
This table is the class Master Alarm table. It gets populated when system init is done. And it contains all the class alarms supported for the device |
|
1.3.6.1.4.1.6296.101.15.2.1.1 | no-access |
|
||
sleAMConfigAlarmClassId | 1.3.6.1.4.1.6296.101.15.2.1.1.1 | amalarmclassid | read-only |
Class ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client |
sleAMConfigAlarmId | 1.3.6.1.4.1.6296.101.15.2.1.1.2 | amalarmid | read-only |
Alarm ID Alarm ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client |
sleAMConfigAlarmName | 1.3.6.1.4.1.6296.101.15.2.1.1.3 | octet string | read-write |
Alarm Name string |
sleAMConfigAlarmSeverity | 1.3.6.1.4.1.6296.101.15.2.1.1.4 | amalarmseverity | read-only |
Alarm severity: The default severity is pre-defined by each Alarm manager clients critical(1), major(2), minor(3), warning(4), intermediate(5), |
sleAMConfigAlarmEnableState | 1.3.6.1.4.1.6296.101.15.2.1.1.5 | amtrapstate | read-only |
Alarm Trap State. Based on the trap state, the alarm will be notified to NMS. If the TRAP STATE is enabled then the alarm will be notified else wont be notified. enable (1) disabe (0) |
sleAMConfigAlarmRaiseGuardTime | 1.3.6.1.4.1.6296.101.15.2.1.1.6 | amalarmguardtime | read-only |
Alarm raise Soaking time. When any alarm is raised, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time) |
sleAMConfigAlarmClearGuardTime | 1.3.6.1.4.1.6296.101.15.2.1.1.7 | amalarmguardtime | read-only |
Alarm clear Soaking time. When any alarm is cleared, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time) |
sleAMConfigAlarmLed | 1.3.6.1.4.1.6296.101.15.2.1.1.8 | integer | read-write |
Alarm led configuration. Determinde led operate or not, when alarms occur. off(0): led not operate on(1) : led operate Enumeration: 'on': 1, 'off': 0. |
sleAMConfigSpecificId | 1.3.6.1.4.1.6296.101.15.2.1.1.9 | integer32 | read-write |
Alarm Configuration specific ID(4bytes) classId and alarmID are combinded with a specificID * 1st,2nd Bytes - ClassId * 3rd,4th bytes - alarmID |
sleAMConfigControl | 1.3.6.1.4.1.6296.101.15.2.2 | |||
sleAMConfigControlRequest | 1.3.6.1.4.1.6296.101.15.2.2.1 | integer | read-write |
The configuration commands, and user can configure functions via setting this entry as proper value. Enumeration: 'setAMConfigClearGuardTime': 3, 'setAMConfigRaiseGuardTime': 2, 'setAMConfigSeverity': 4, 'setAMConfigTrapEnableState': 1, 'setAMConfigLed': 5. |
sleAMConfigControlStatus | 1.3.6.1.4.1.6296.101.15.2.2.2 | slecontrolstatustype | read-only |
status of user command. User have to check this value as .busy. or .idle. before do setRequest. |
sleAMConfigControlTimer | 1.3.6.1.4.1.6296.101.15.2.2.3 | gauge32 | read-write |
the wait-time until setRequest end. In case of short-time command, this value is 0 |
sleAMConfigControlTimeStamp | 1.3.6.1.4.1.6296.101.15.2.2.4 | timeticks | read-only |
the time stamp of the last command. (don.t care) |
sleAMConfigControlReqResult | 1.3.6.1.4.1.6296.101.15.2.2.5 | slecontrolrequestresulttype | read-only |
Result of the last command. |
sleAMConfigControlAlarmClassId | 1.3.6.1.4.1.6296.101.15.2.2.6 | amalarmclassid | read-write |
Alarm Manager Class ID |
sleAMConfigControlAlarmId | 1.3.6.1.4.1.6296.101.15.2.2.7 | amalarmid | read-write |
Alarm Manager Alarm Index |
sleAMConfigControlSeverity | 1.3.6.1.4.1.6296.101.15.2.2.8 | amalarmseverity | read-write |
Alarm Class Severity critical(1), major(2), minor(3), warning(4), ignore(5), default(6) |
sleAMConfigControlEnableState | 1.3.6.1.4.1.6296.101.15.2.2.9 | amtrapstate | read-write |
Alarm Trap State. Based on the trap state, the alarm will be notified to NMS. If the TRAP STATE is enabled then the alarm will be notified else wont be notified. enable (1) disabe (0) |
sleAMConfigControlRaiseGuardTime | 1.3.6.1.4.1.6296.101.15.2.2.10 | amalarmguardtime | read-write |
Alarm Raise Soaking time. When any alarm is raised, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time) |
sleAMConfigControlClearGuardTime | 1.3.6.1.4.1.6296.101.15.2.2.11 | amalarmguardtime | read-write |
Alarm clear Soaking time. When any alarm is cleared, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time) |
sleAMConfigControlLed | 1.3.6.1.4.1.6296.101.15.2.2.12 | integer32 | read-write |
Alarm led configuration. Determinde led operate or not, when alarms occur. off(0): led not operate on(1) : led operate |
sleAMConfigNotification | 1.3.6.1.4.1.6296.101.15.2.3 | |||
sleAMConfigSeverityChanged | 1.3.6.1.4.1.6296.101.15.2.3.1 |
Notification for Alarm severity change |
||
sleAMConfigEnableStateChanged | 1.3.6.1.4.1.6296.101.15.2.3.2 |
Notification for Class Trap State change |
||
sleAMConfigRaiseGuardTimeChanged | 1.3.6.1.4.1.6296.101.15.2.3.3 |
Notification for Raise Soak time change |
||
sleAMConfigClearGuardTimeChanged | 1.3.6.1.4.1.6296.101.15.2.3.4 |
Notification for Clear Soak time change |
||
sleAMConfigLedChanged | 1.3.6.1.4.1.6296.101.15.2.3.5 |
Notification for Alarm led configuration change |
||
sleAMCurrentBase | 1.3.6.1.4.1.6296.101.15.3 | |||
sleAMCurrentTable | 1.3.6.1.4.1.6296.101.15.3.1 | no-access |
This table contains the current active alarms for the Alarm Class. Each Row in this table gets populated when any Alarm is raised |
|
1.3.6.1.4.1.6296.101.15.3.1.1 | no-access |
|
||
sleAMCurrentSeqId | 1.3.6.1.4.1.6296.101.15.3.1.1.1 | unsigned32 | read-only |
alarm sequence id key of current alarm table it generated by alarm-manager automatically |
sleAMCurrentAlarmSource | 1.3.6.1.4.1.6296.101.15.3.1.1.2 | amalarmsrc | read-only |
alarm location infomation |type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location value |
sleAMCurrentAlarmClassId | 1.3.6.1.4.1.6296.101.15.3.1.1.3 | amalarmclassid | read-only |
Class ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client |
sleAMCurrentAlarmId | 1.3.6.1.4.1.6296.101.15.3.1.1.4 | amalarmid | read-only |
Alarm ID Alarm ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client |
sleAMCurrentAlarmStatus | 1.3.6.1.4.1.6296.101.15.3.1.1.5 | alarmstatus | read-only |
Current Alarm State: raised (1), masked(2) |
sleAMCurrentAlarmSeverity | 1.3.6.1.4.1.6296.101.15.3.1.1.6 | amalarmseverity | read-only |
Current Alarm Severity: critical(1), major(2), minor(3), warning(4) |
sleAMCurrentAlarmReason | 1.3.6.1.4.1.6296.101.15.3.1.1.7 | amalarmreason | read-only |
reasion string |
sleAMCurrentTimeAndDate | 1.3.6.1.4.1.6296.101.15.3.1.1.8 | timeticks | read-only |
Current Alarm Time and Date |
sleAMCurrentSpecificId | 1.3.6.1.4.1.6296.101.15.3.1.1.9 | integer | read-write |
Current Alarm specific ID(4bytes) classId and alarmID are combinded with a specificID * 1st,2nd Bytes - ClassId * 3rd,4th bytes - alarmID |
sleAMCurrentControl | 1.3.6.1.4.1.6296.101.15.3.2 | |||
sleAMCurrentControlRequest | 1.3.6.1.4.1.6296.101.15.3.2.1 | integer | read-write |
The configuration commands, and user can configure functions via setting this entry as proper value. 1: all current alarm clear 2: current alarm clear by SeqId 3: current alarm clear by Source(location) Enumeration: 'alarmClearBySource': 3, 'allAlarmClear': 1, 'alarmClearBySeqId': 2. |
sleAMCurrentControlStatus | 1.3.6.1.4.1.6296.101.15.3.2.2 | slecontrolstatustype | read-only |
status of user command. User have to check this value as .busy. or .idle. before do setRequest. |
sleAMCurrentControlTimer | 1.3.6.1.4.1.6296.101.15.3.2.3 | gauge32 | read-write |
the wait-time until setRequest end. In case of short-time command, this value is 0 |
sleAMCurrentControlTimeStamp | 1.3.6.1.4.1.6296.101.15.3.2.4 | timeticks | read-only |
the time stamp of the last command. (don.t care) |
sleAMCurrentControlReqResult | 1.3.6.1.4.1.6296.101.15.3.2.5 | slecontrolrequestresulttype | read-only |
Result of the last command. |
sleAMCurrentControlSeqId | 1.3.6.1.4.1.6296.101.15.3.2.6 | unsigned32 | read-write |
current alarmControl Sequence ID.(0, all mcurrent alarm cleared) Valid only if the sleAMHistoryControlRequest value is set to 2(alarmHistoryClearBySeqId). |
sleAMCurrentControlSource | 1.3.6.1.4.1.6296.101.15.3.2.7 | amalarmsrc | read-write |
current alarm clear location infomation |type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location value |
sleAMCurrentNotification | 1.3.6.1.4.1.6296.101.15.3.3 | |||
sleAMCurrentAlarmCleared | 1.3.6.1.4.1.6296.101.15.3.3.1 |
Notification for current alarm clear |
||
sleAlarmTrapAlarm | 1.3.6.1.4.1.6296.101.15.3.3.2 |
Notify Alarm Raise/Clear TRAPS to NMS for each entry in the Table |
||
sleAlarmTrapEvent | 1.3.6.1.4.1.6296.101.15.3.3.3 |
Notify Event Occur TRAPS to NMS for each entry in the Table |
||
sleAMHistoryBase | 1.3.6.1.4.1.6296.101.15.4 | |||
sleAMHistoryTable | 1.3.6.1.4.1.6296.101.15.4.1 | no-access |
This Table is used to for keeping the Alarm History |
|
1.3.6.1.4.1.6296.101.15.4.1.1 | no-access |
|
||
sleAMHistorySeqId | 1.3.6.1.4.1.6296.101.15.4.1.1.1 | unsigned32 | read-only |
Alarm History Sequence ID. This sequence Id is maintained based on the TRAP sent. |
sleAMHistoryAlarmSource | 1.3.6.1.4.1.6296.101.15.4.1.1.2 | amalarmsrc | read-only |
|type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location value |
sleAMHistoryAlarmClassId | 1.3.6.1.4.1.6296.101.15.4.1.1.3 | amalarmclassid | read-only |
Class ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client |
sleAMHistoryAlarmId | 1.3.6.1.4.1.6296.101.15.4.1.1.4 | amalarmid | read-only |
History Alarm ID Alarm ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client |
sleAMHistoryAlarmStatus | 1.3.6.1.4.1.6296.101.15.4.1.1.5 | alarmstatus | read-only |
History Alarm State: cleared (0), raised (1), masked(2) |
sleAMHistoryAlarmSeverity | 1.3.6.1.4.1.6296.101.15.4.1.1.6 | amalarmseverity | read-only |
History alarm Severity critical(1), major(2), minor(3), warning(4) |
sleAMHistoryAlarmReason | 1.3.6.1.4.1.6296.101.15.4.1.1.7 | amalarmreason | read-write |
History alarm Reason string |
sleAMHistoryAlarmTimeDate | 1.3.6.1.4.1.6296.101.15.4.1.1.8 | timeticks | read-only |
History Alarm Time and Date |
sleAMHistorySpecificId | 1.3.6.1.4.1.6296.101.15.4.1.1.9 | integer32 | read-write |
Alarm History specific ID(4bytes) classId and alarmID are combinded with a specificID * 1st,2nd Bytes - ClassId * 3rd,4th bytes - alarmID |
sleAMHistoryControl | 1.3.6.1.4.1.6296.101.15.4.2 | |||
sleAMHistoryControlRequest | 1.3.6.1.4.1.6296.101.15.4.2.1 | integer | read-write |
The configuration commands, and user can configure functions via setting this entry as proper value. clearAlarmHistory : clears the alarms from the History Table 1: all alarm history clear 2: alarm history clear by SeqId 3: alarm history clear by Source(location) Enumeration: 'alarmHistoryClearBySource': 3, 'allAlarmHistoryClear': 1, 'alarmHistoryClearBySeqId': 2. |
sleAMHistoryControlStatus | 1.3.6.1.4.1.6296.101.15.4.2.2 | slecontrolstatustype | read-only |
status of user command. User have to check this value as .busy. or .idle. before do setRequest. |
sleAMHistoryControlTimer | 1.3.6.1.4.1.6296.101.15.4.2.3 | gauge32 | read-write |
the wait-time until setRequest end. In case of short-time command, this value is 0 |
sleAMHistoryControlTimeStamp | 1.3.6.1.4.1.6296.101.15.4.2.4 | timeticks | read-only |
the time stamp of the last command. (don.t care) |
sleAMHistoryControlReqResult | 1.3.6.1.4.1.6296.101.15.4.2.5 | slecontrolrequestresulttype | read-only |
Result of the last command. |
sleAMHistoryControSeqId | 1.3.6.1.4.1.6296.101.15.4.2.6 | unsigned32 | read-write |
Alarm History Control Sequence ID. Specify cleared history alarm ID (0, all alarm history cleared) |
sleAMHistoryControSource | 1.3.6.1.4.1.6296.101.15.4.2.7 | amalarmsrc | read-write |
alarm history clear location infomation Valid only if the sleAMHistoryControlRequest value is set to 3(alarmHistoryClearBySource). |type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location value |
sleAMHistoryNotification | 1.3.6.1.4.1.6296.101.15.4.3 | |||
sleAMHistoryAlarmCleared | 1.3.6.1.4.1.6296.101.15.4.3.1 |
Notification for History Class cleared |
||
sleAMAcoBase | 1.3.6.1.4.1.6296.101.15.5 | |||
sleAMAcoInfoEntry | 1.3.6.1.4.1.6296.101.15.5.1 | |||
sleAMAcoInfo | 1.3.6.1.4.1.6296.101.15.5.1.1 | amalarmaco | read-only |
ACO control configuration acoOff(1) : buzzer operation enable. acoOn(2) : buzzer operation disable. acoOpr(3) : current buzzer cut. |
sleAMAcoControl | 1.3.6.1.4.1.6296.101.15.5.2 | |||
sleAMAcoControlRequest | 1.3.6.1.4.1.6296.101.15.5.2.1 | integer | read-write |
The configuration commands, and user can configure functions via setting this entry as proper value. Enumeration: 'setAco': 2, 'oprAco': 1. |
sleAMAcogControlStatus | 1.3.6.1.4.1.6296.101.15.5.2.2 | slecontrolstatustype | read-only |
status of user command. User have to check this value as .busy. or .idle. before do setRequest. |
sleAMAcoControlTimer | 1.3.6.1.4.1.6296.101.15.5.2.3 | gauge32 | read-write |
the wait-time until setRequest end. In case of short-time command, this value is 0 |
sleAMAcoControlTimeStamp | 1.3.6.1.4.1.6296.101.15.5.2.4 | timeticks | read-only |
the time stamp of the last command. (don.t care) |
sleAMAcoControlReqResult | 1.3.6.1.4.1.6296.101.15.5.2.5 | slecontrolrequestresulttype | read-only |
Result of the last command. |
sleAMAcoControlSet | 1.3.6.1.4.1.6296.101.15.5.2.6 | amalarmaco | read-write |
ACO control acoOff(1) : buzzer operation enable. acoOn(2) : buzzer operation disable. acoOpr(3) : current buzzer cut. |
sleAMAcoNotification | 1.3.6.1.4.1.6296.101.15.5.3 | |||
sleAMAcoChanged | 1.3.6.1.4.1.6296.101.15.5.3.1 |
Notification for Alarm ACO configuration change |
||
sleAMLedBase | 1.3.6.1.4.1.6296.101.15.6 | |||
sleAMLedTable | 1.3.6.1.4.1.6296.101.15.6.1 | no-access |
This table contains the LED status and configuration. |
|
1.3.6.1.4.1.6296.101.15.6.1.1 | no-access |
|
||
sleAMLedSeverity | 1.3.6.1.4.1.6296.101.15.6.1.1.1 | integer | read-write |
LED Alarm Severity critical(1), major(2), minor(3), Enumeration: 'major': 2, 'critical': 1, 'minor': 3. |
sleAMLedSet | 1.3.6.1.4.1.6296.101.15.6.1.1.2 | amalarmled | read-write |
ACO control configuration acoOff(1) : buzzer operation enable. acoOn(2) : buzzer operation disable. acoOpr(3) : current buzzer cut. |
sleAMLedCount | 1.3.6.1.4.1.6296.101.15.6.1.1.3 | integer32 | read-write |
alarm count of the associated led |
sleAMLedControl | 1.3.6.1.4.1.6296.101.15.6.2 | |||
sleAMLedControlRequest | 1.3.6.1.4.1.6296.101.15.6.2.1 | integer | read-write |
The configuration commands, and user can configure functions via setting this entry as proper value. Enumeration: 'setLed': 2, 'ledCount': 3, 'oprLed': 1. |
sleAMLedControlStatus | 1.3.6.1.4.1.6296.101.15.6.2.2 | slecontrolstatustype | read-only |
status of user command. User have to check this value as .busy. or .idle. before do setRequest. |
sleAMLedControlTimer | 1.3.6.1.4.1.6296.101.15.6.2.3 | gauge32 | read-write |
the wait-time until setRequest end. In case of short-time command, this value is 0 |
sleAMLedControlTimeStamp | 1.3.6.1.4.1.6296.101.15.6.2.4 | timeticks | read-only |
the time stamp of the last command. (don.t care) |
sleAMLedControlReqResult | 1.3.6.1.4.1.6296.101.15.6.2.5 | slecontrolrequestresulttype | read-only |
Result of the last command. |
sleAMLedControlSeverity | 1.3.6.1.4.1.6296.101.15.6.2.6 | integer | read-write |
LED Alarm Severity critical(1), major(2), minor(3), Enumeration: 'all': 0, 'critical': 1, 'major': 2, 'minor': 3. |
sleAMLedControlSet | 1.3.6.1.4.1.6296.101.15.6.2.7 | amalarmled | read-write |
LED control configuration ledOff(1) : LED operation disable. ledOn(2) : LED operation enable. ledOpr(3) : current LED off. |
sleAMLedNotification | 1.3.6.1.4.1.6296.101.15.6.3 | |||
sleAMLedChanged | 1.3.6.1.4.1.6296.101.15.6.3.1 |
Notification for LED configuration change |