SLE-AM-MIB: View SNMP OID List / Download MIB

VENDOR: DASAN CO.,LTD.


 Home MIB: SLE-AM-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 sleAlarmMgr 1.3.6.1.4.1.6296.101.15
This MIB contains all needed informations about Alarm Manager.
       sleAMAlarmTrapNeId 1.3.6.1.4.1.6296.101.15.1 octet string read-only
use for NE idendification when alarm(or event) trap system MAC address
       sleAMConfigBase 1.3.6.1.4.1.6296.101.15.2
           sleAMConfigTable 1.3.6.1.4.1.6296.101.15.2.1 no-access
This table is the class Master Alarm table. It gets populated when system init is done. And it contains all the class alarms supported for the device
               sleAMConfigEntry 1.3.6.1.4.1.6296.101.15.2.1.1 no-access
                   sleAMConfigAlarmClassId 1.3.6.1.4.1.6296.101.15.2.1.1.1 amalarmclassid read-only
Class ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client
                   sleAMConfigAlarmId 1.3.6.1.4.1.6296.101.15.2.1.1.2 amalarmid read-only
Alarm ID Alarm ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client
                   sleAMConfigAlarmName 1.3.6.1.4.1.6296.101.15.2.1.1.3 octet string read-write
Alarm Name string
                   sleAMConfigAlarmSeverity 1.3.6.1.4.1.6296.101.15.2.1.1.4 amalarmseverity read-only
Alarm severity: The default severity is pre-defined by each Alarm manager clients critical(1), major(2), minor(3), warning(4), intermediate(5),
                   sleAMConfigAlarmEnableState 1.3.6.1.4.1.6296.101.15.2.1.1.5 amtrapstate read-only
Alarm Trap State. Based on the trap state, the alarm will be notified to NMS. If the TRAP STATE is enabled then the alarm will be notified else wont be notified. enable (1) disabe (0)
                   sleAMConfigAlarmRaiseGuardTime 1.3.6.1.4.1.6296.101.15.2.1.1.6 amalarmguardtime read-only
Alarm raise Soaking time. When any alarm is raised, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time)
                   sleAMConfigAlarmClearGuardTime 1.3.6.1.4.1.6296.101.15.2.1.1.7 amalarmguardtime read-only
Alarm clear Soaking time. When any alarm is cleared, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time)
                   sleAMConfigAlarmLed 1.3.6.1.4.1.6296.101.15.2.1.1.8 integer read-write
Alarm led configuration. Determinde led operate or not, when alarms occur. off(0): led not operate on(1) : led operate Enumeration: 'on': 1, 'off': 0.
                   sleAMConfigSpecificId 1.3.6.1.4.1.6296.101.15.2.1.1.9 integer32 read-write
Alarm Configuration specific ID(4bytes) classId and alarmID are combinded with a specificID * 1st,2nd Bytes - ClassId * 3rd,4th bytes - alarmID
           sleAMConfigControl 1.3.6.1.4.1.6296.101.15.2.2
               sleAMConfigControlRequest 1.3.6.1.4.1.6296.101.15.2.2.1 integer read-write
The configuration commands, and user can configure functions via setting this entry as proper value. Enumeration: 'setAMConfigClearGuardTime': 3, 'setAMConfigRaiseGuardTime': 2, 'setAMConfigSeverity': 4, 'setAMConfigTrapEnableState': 1, 'setAMConfigLed': 5.
               sleAMConfigControlStatus 1.3.6.1.4.1.6296.101.15.2.2.2 slecontrolstatustype read-only
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
               sleAMConfigControlTimer 1.3.6.1.4.1.6296.101.15.2.2.3 gauge32 read-write
the wait-time until setRequest end. In case of short-time command, this value is 0
               sleAMConfigControlTimeStamp 1.3.6.1.4.1.6296.101.15.2.2.4 timeticks read-only
the time stamp of the last command. (don.t care)
               sleAMConfigControlReqResult 1.3.6.1.4.1.6296.101.15.2.2.5 slecontrolrequestresulttype read-only
Result of the last command.
               sleAMConfigControlAlarmClassId 1.3.6.1.4.1.6296.101.15.2.2.6 amalarmclassid read-write
Alarm Manager Class ID
               sleAMConfigControlAlarmId 1.3.6.1.4.1.6296.101.15.2.2.7 amalarmid read-write
Alarm Manager Alarm Index
               sleAMConfigControlSeverity 1.3.6.1.4.1.6296.101.15.2.2.8 amalarmseverity read-write
Alarm Class Severity critical(1), major(2), minor(3), warning(4), ignore(5), default(6)
               sleAMConfigControlEnableState 1.3.6.1.4.1.6296.101.15.2.2.9 amtrapstate read-write
Alarm Trap State. Based on the trap state, the alarm will be notified to NMS. If the TRAP STATE is enabled then the alarm will be notified else wont be notified. enable (1) disabe (0)
               sleAMConfigControlRaiseGuardTime 1.3.6.1.4.1.6296.101.15.2.2.10 amalarmguardtime read-write
Alarm Raise Soaking time. When any alarm is raised, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time)
               sleAMConfigControlClearGuardTime 1.3.6.1.4.1.6296.101.15.2.2.11 amalarmguardtime read-write
Alarm clear Soaking time. When any alarm is cleared, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time)
               sleAMConfigControlLed 1.3.6.1.4.1.6296.101.15.2.2.12 integer32 read-write
Alarm led configuration. Determinde led operate or not, when alarms occur. off(0): led not operate on(1) : led operate
           sleAMConfigNotification 1.3.6.1.4.1.6296.101.15.2.3
               sleAMConfigSeverityChanged 1.3.6.1.4.1.6296.101.15.2.3.1
Notification for Alarm severity change
               sleAMConfigEnableStateChanged 1.3.6.1.4.1.6296.101.15.2.3.2
Notification for Class Trap State change
               sleAMConfigRaiseGuardTimeChanged 1.3.6.1.4.1.6296.101.15.2.3.3
Notification for Raise Soak time change
               sleAMConfigClearGuardTimeChanged 1.3.6.1.4.1.6296.101.15.2.3.4
Notification for Clear Soak time change
               sleAMConfigLedChanged 1.3.6.1.4.1.6296.101.15.2.3.5
Notification for Alarm led configuration change
       sleAMCurrentBase 1.3.6.1.4.1.6296.101.15.3
           sleAMCurrentTable 1.3.6.1.4.1.6296.101.15.3.1 no-access
This table contains the current active alarms for the Alarm Class. Each Row in this table gets populated when any Alarm is raised
               sleAMCurrentEntry 1.3.6.1.4.1.6296.101.15.3.1.1 no-access
                   sleAMCurrentSeqId 1.3.6.1.4.1.6296.101.15.3.1.1.1 unsigned32 read-only
alarm sequence id key of current alarm table it generated by alarm-manager automatically
                   sleAMCurrentAlarmSource 1.3.6.1.4.1.6296.101.15.3.1.1.2 amalarmsrc read-only
alarm location infomation |type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location value
                   sleAMCurrentAlarmClassId 1.3.6.1.4.1.6296.101.15.3.1.1.3 amalarmclassid read-only
Class ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client
                   sleAMCurrentAlarmId 1.3.6.1.4.1.6296.101.15.3.1.1.4 amalarmid read-only
Alarm ID Alarm ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client
                   sleAMCurrentAlarmStatus 1.3.6.1.4.1.6296.101.15.3.1.1.5 alarmstatus read-only
Current Alarm State: raised (1), masked(2)
                   sleAMCurrentAlarmSeverity 1.3.6.1.4.1.6296.101.15.3.1.1.6 amalarmseverity read-only
Current Alarm Severity: critical(1), major(2), minor(3), warning(4)
                   sleAMCurrentAlarmReason 1.3.6.1.4.1.6296.101.15.3.1.1.7 amalarmreason read-only
reasion string
                   sleAMCurrentTimeAndDate 1.3.6.1.4.1.6296.101.15.3.1.1.8 timeticks read-only
Current Alarm Time and Date
                   sleAMCurrentSpecificId 1.3.6.1.4.1.6296.101.15.3.1.1.9 integer read-write
Current Alarm specific ID(4bytes) classId and alarmID are combinded with a specificID * 1st,2nd Bytes - ClassId * 3rd,4th bytes - alarmID
           sleAMCurrentControl 1.3.6.1.4.1.6296.101.15.3.2
               sleAMCurrentControlRequest 1.3.6.1.4.1.6296.101.15.3.2.1 integer read-write
The configuration commands, and user can configure functions via setting this entry as proper value. 1: all current alarm clear 2: current alarm clear by SeqId 3: current alarm clear by Source(location) Enumeration: 'alarmClearBySource': 3, 'allAlarmClear': 1, 'alarmClearBySeqId': 2.
               sleAMCurrentControlStatus 1.3.6.1.4.1.6296.101.15.3.2.2 slecontrolstatustype read-only
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
               sleAMCurrentControlTimer 1.3.6.1.4.1.6296.101.15.3.2.3 gauge32 read-write
the wait-time until setRequest end. In case of short-time command, this value is 0
               sleAMCurrentControlTimeStamp 1.3.6.1.4.1.6296.101.15.3.2.4 timeticks read-only
the time stamp of the last command. (don.t care)
               sleAMCurrentControlReqResult 1.3.6.1.4.1.6296.101.15.3.2.5 slecontrolrequestresulttype read-only
Result of the last command.
               sleAMCurrentControlSeqId 1.3.6.1.4.1.6296.101.15.3.2.6 unsigned32 read-write
current alarmControl Sequence ID.(0, all mcurrent alarm cleared) Valid only if the sleAMHistoryControlRequest value is set to 2(alarmHistoryClearBySeqId).
               sleAMCurrentControlSource 1.3.6.1.4.1.6296.101.15.3.2.7 amalarmsrc read-write
current alarm clear location infomation |type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location value
           sleAMCurrentNotification 1.3.6.1.4.1.6296.101.15.3.3
               sleAMCurrentAlarmCleared 1.3.6.1.4.1.6296.101.15.3.3.1
Notification for current alarm clear
               sleAlarmTrapAlarm 1.3.6.1.4.1.6296.101.15.3.3.2
Notify Alarm Raise/Clear TRAPS to NMS for each entry in the Table
               sleAlarmTrapEvent 1.3.6.1.4.1.6296.101.15.3.3.3
Notify Event Occur TRAPS to NMS for each entry in the Table
       sleAMHistoryBase 1.3.6.1.4.1.6296.101.15.4
           sleAMHistoryTable 1.3.6.1.4.1.6296.101.15.4.1 no-access
This Table is used to for keeping the Alarm History
               sleAMHistoryEntry 1.3.6.1.4.1.6296.101.15.4.1.1 no-access
                   sleAMHistorySeqId 1.3.6.1.4.1.6296.101.15.4.1.1.1 unsigned32 read-only
Alarm History Sequence ID. This sequence Id is maintained based on the TRAP sent.
                   sleAMHistoryAlarmSource 1.3.6.1.4.1.6296.101.15.4.1.1.2 amalarmsrc read-only
|type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location value
                   sleAMHistoryAlarmClassId 1.3.6.1.4.1.6296.101.15.4.1.1.3 amalarmclassid read-only
Class ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client
                   sleAMHistoryAlarmId 1.3.6.1.4.1.6296.101.15.4.1.1.4 amalarmid read-only
History Alarm ID Alarm ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-client
                   sleAMHistoryAlarmStatus 1.3.6.1.4.1.6296.101.15.4.1.1.5 alarmstatus read-only
History Alarm State: cleared (0), raised (1), masked(2)
                   sleAMHistoryAlarmSeverity 1.3.6.1.4.1.6296.101.15.4.1.1.6 amalarmseverity read-only
History alarm Severity critical(1), major(2), minor(3), warning(4)
                   sleAMHistoryAlarmReason 1.3.6.1.4.1.6296.101.15.4.1.1.7 amalarmreason read-write
History alarm Reason string
                   sleAMHistoryAlarmTimeDate 1.3.6.1.4.1.6296.101.15.4.1.1.8 timeticks read-only
History Alarm Time and Date
                   sleAMHistorySpecificId 1.3.6.1.4.1.6296.101.15.4.1.1.9 integer32 read-write
Alarm History specific ID(4bytes) classId and alarmID are combinded with a specificID * 1st,2nd Bytes - ClassId * 3rd,4th bytes - alarmID
           sleAMHistoryControl 1.3.6.1.4.1.6296.101.15.4.2
               sleAMHistoryControlRequest 1.3.6.1.4.1.6296.101.15.4.2.1 integer read-write
The configuration commands, and user can configure functions via setting this entry as proper value. clearAlarmHistory : clears the alarms from the History Table 1: all alarm history clear 2: alarm history clear by SeqId 3: alarm history clear by Source(location) Enumeration: 'alarmHistoryClearBySource': 3, 'allAlarmHistoryClear': 1, 'alarmHistoryClearBySeqId': 2.
               sleAMHistoryControlStatus 1.3.6.1.4.1.6296.101.15.4.2.2 slecontrolstatustype read-only
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
               sleAMHistoryControlTimer 1.3.6.1.4.1.6296.101.15.4.2.3 gauge32 read-write
the wait-time until setRequest end. In case of short-time command, this value is 0
               sleAMHistoryControlTimeStamp 1.3.6.1.4.1.6296.101.15.4.2.4 timeticks read-only
the time stamp of the last command. (don.t care)
               sleAMHistoryControlReqResult 1.3.6.1.4.1.6296.101.15.4.2.5 slecontrolrequestresulttype read-only
Result of the last command.
               sleAMHistoryControSeqId 1.3.6.1.4.1.6296.101.15.4.2.6 unsigned32 read-write
Alarm History Control Sequence ID. Specify cleared history alarm ID (0, all alarm history cleared)
               sleAMHistoryControSource 1.3.6.1.4.1.6296.101.15.4.2.7 amalarmsrc read-write
alarm history clear location infomation Valid only if the sleAMHistoryControlRequest value is set to 3(alarmHistoryClearBySource). |type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location value
           sleAMHistoryNotification 1.3.6.1.4.1.6296.101.15.4.3
               sleAMHistoryAlarmCleared 1.3.6.1.4.1.6296.101.15.4.3.1
Notification for History Class cleared
       sleAMAcoBase 1.3.6.1.4.1.6296.101.15.5
           sleAMAcoInfoEntry 1.3.6.1.4.1.6296.101.15.5.1
               sleAMAcoInfo 1.3.6.1.4.1.6296.101.15.5.1.1 amalarmaco read-only
ACO control configuration acoOff(1) : buzzer operation enable. acoOn(2) : buzzer operation disable. acoOpr(3) : current buzzer cut.
           sleAMAcoControl 1.3.6.1.4.1.6296.101.15.5.2
               sleAMAcoControlRequest 1.3.6.1.4.1.6296.101.15.5.2.1 integer read-write
The configuration commands, and user can configure functions via setting this entry as proper value. Enumeration: 'setAco': 2, 'oprAco': 1.
               sleAMAcogControlStatus 1.3.6.1.4.1.6296.101.15.5.2.2 slecontrolstatustype read-only
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
               sleAMAcoControlTimer 1.3.6.1.4.1.6296.101.15.5.2.3 gauge32 read-write
the wait-time until setRequest end. In case of short-time command, this value is 0
               sleAMAcoControlTimeStamp 1.3.6.1.4.1.6296.101.15.5.2.4 timeticks read-only
the time stamp of the last command. (don.t care)
               sleAMAcoControlReqResult 1.3.6.1.4.1.6296.101.15.5.2.5 slecontrolrequestresulttype read-only
Result of the last command.
               sleAMAcoControlSet 1.3.6.1.4.1.6296.101.15.5.2.6 amalarmaco read-write
ACO control acoOff(1) : buzzer operation enable. acoOn(2) : buzzer operation disable. acoOpr(3) : current buzzer cut.
           sleAMAcoNotification 1.3.6.1.4.1.6296.101.15.5.3
               sleAMAcoChanged 1.3.6.1.4.1.6296.101.15.5.3.1
Notification for Alarm ACO configuration change
       sleAMLedBase 1.3.6.1.4.1.6296.101.15.6
           sleAMLedTable 1.3.6.1.4.1.6296.101.15.6.1 no-access
This table contains the LED status and configuration.
               sleAMLedEntry 1.3.6.1.4.1.6296.101.15.6.1.1 no-access
                   sleAMLedSeverity 1.3.6.1.4.1.6296.101.15.6.1.1.1 integer read-write
LED Alarm Severity critical(1), major(2), minor(3), Enumeration: 'major': 2, 'critical': 1, 'minor': 3.
                   sleAMLedSet 1.3.6.1.4.1.6296.101.15.6.1.1.2 amalarmled read-write
ACO control configuration acoOff(1) : buzzer operation enable. acoOn(2) : buzzer operation disable. acoOpr(3) : current buzzer cut.
                   sleAMLedCount 1.3.6.1.4.1.6296.101.15.6.1.1.3 integer32 read-write
alarm count of the associated led
           sleAMLedControl 1.3.6.1.4.1.6296.101.15.6.2
               sleAMLedControlRequest 1.3.6.1.4.1.6296.101.15.6.2.1 integer read-write
The configuration commands, and user can configure functions via setting this entry as proper value. Enumeration: 'setLed': 2, 'ledCount': 3, 'oprLed': 1.
               sleAMLedControlStatus 1.3.6.1.4.1.6296.101.15.6.2.2 slecontrolstatustype read-only
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
               sleAMLedControlTimer 1.3.6.1.4.1.6296.101.15.6.2.3 gauge32 read-write
the wait-time until setRequest end. In case of short-time command, this value is 0
               sleAMLedControlTimeStamp 1.3.6.1.4.1.6296.101.15.6.2.4 timeticks read-only
the time stamp of the last command. (don.t care)
               sleAMLedControlReqResult 1.3.6.1.4.1.6296.101.15.6.2.5 slecontrolrequestresulttype read-only
Result of the last command.
               sleAMLedControlSeverity 1.3.6.1.4.1.6296.101.15.6.2.6 integer read-write
LED Alarm Severity critical(1), major(2), minor(3), Enumeration: 'all': 0, 'critical': 1, 'major': 2, 'minor': 3.
               sleAMLedControlSet 1.3.6.1.4.1.6296.101.15.6.2.7 amalarmled read-write
LED control configuration ledOff(1) : LED operation disable. ledOn(2) : LED operation enable. ledOpr(3) : current LED off.
           sleAMLedNotification 1.3.6.1.4.1.6296.101.15.6.3
               sleAMLedChanged 1.3.6.1.4.1.6296.101.15.6.3.1
Notification for LED configuration change