Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 asentria 1.3.6.1.4.1.3052
           sl10 1.3.6.1.4.1.3052.40
                 device 1.3.6.1.4.1.3052.40.1
                     serialNumber 1.3.6.1.4.1.3052.40.1.1 displaystring read-only
8-character serial number
                     firmwareVersion 1.3.6.1.4.1.3052.40.1.2 displaystring read-only
Firmware version text string
                     siteID 1.3.6.1.4.1.3052.40.1.3 displaystring read-write
Site Identifier, up to 12 characters.
                     snmpManager 1.3.6.1.4.1.3052.40.1.4 ipaddress read-write
This is snmp manager #1
                     input78Mode 1.3.6.1.4.1.3052.40.1.5 integer read-only
Mode of operation of inputs 7/8. 0-analog 1&2 =default, 1-contacts 7&8
                     forceTraps 1.3.6.1.4.1.3052.40.1.6 integer read-write
Any write non-zero forces set of traps to be send to the SNMP Manager
                     thisTrapText 1.3.6.1.4.1.3052.40.1.7 displaystring read-write
A text string included in all traps
                     alarmStatus 1.3.6.1.4.1.3052.40.1.8 displaystring read-only
A text status of all alarms
                     snmpManager1 1.3.6.1.4.1.3052.40.1.9 ipaddress read-write
SNMP manager #1
                     snmpManager2 1.3.6.1.4.1.3052.40.1.10 ipaddress read-write
SNMP manager #2
                     snmpManager3 1.3.6.1.4.1.3052.40.1.11 ipaddress read-write
SNMP manager #3
                     snmpManager4 1.3.6.1.4.1.3052.40.1.12 ipaddress read-write
SNMP manager #4
                     statusRepeatHours 1.3.6.1.4.1.3052.40.1.13 integer read-write
0=none, 1-24 Number of Hours between Status Traps being Sent
                     serialTimeout 1.3.6.1.4.1.3052.40.1.14 integer read-write
5-30, Minutes of non-activity timeout on serial setup
                     powerupTrapsend 1.3.6.1.4.1.3052.40.1.15 integer read-write
0-no, 1-yes, send traps for all sensors on powerup
                     netlossTrapsend 1.3.6.1.4.1.3052.40.1.16 integer read-write
0-no, 1-yes, send traps for detected netloss and back up
                     buildID 1.3.6.1.4.1.3052.40.1.17 displaystring read-only
5-chars max text for build identifier
                 contacts 1.3.6.1.4.1.3052.40.2
                     contact1 1.3.6.1.4.1.3052.40.2.1
                         contact1Name 1.3.6.1.4.1.3052.40.2.1.1 displaystring read-write
Name for contact, up to 30 characters
                         contact1State 1.3.6.1.4.1.3052.40.2.1.2 integer read-only
Current State of Contact, 0-open 1-closed
                         contact1AlarmEnable 1.3.6.1.4.1.3052.40.2.1.3 integer read-write
0-alarms disabled 1-alarms enabled
                         contact1ActiveDirection 1.3.6.1.4.1.3052.40.2.1.4 integer read-write
0-alarm on open 1-alarm on closed
                         contact1Threshold 1.3.6.1.4.1.3052.40.2.1.5 integer read-write
Number of seconds that the contact must remain in a state before generating a trap, range 0-255
                         contact1ReturnNormalTrap 1.3.6.1.4.1.3052.40.2.1.6 integer read-write
0-return to normal traps not sent, 1-sent
                         contact1TrapRepeat 1.3.6.1.4.1.3052.40.2.1.7 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps.
                         contact1Severity 1.3.6.1.4.1.3052.40.2.1.8 integer read-write
1-minor 2-major 3-critical 4-severe 5-warning
                     contact2 1.3.6.1.4.1.3052.40.2.2
                         contact2Name 1.3.6.1.4.1.3052.40.2.2.1 displaystring read-write
Name for contact, up to 30 characters
                         contact2State 1.3.6.1.4.1.3052.40.2.2.2 integer read-only
Current State of Contact, 0-open 1-closed
                         contact2AlarmEnable 1.3.6.1.4.1.3052.40.2.2.3 integer read-write
0-no alarms 1-alarms enabled
                         contact2ActiveDirection 1.3.6.1.4.1.3052.40.2.2.4 integer read-write
0-alarm on open 1-alarm on closed
                         contact2Threshold 1.3.6.1.4.1.3052.40.2.2.5 integer read-write
Number of seconds must be in a state to be 'open' or 'closed'
                         contact2ReturnNormalTrap 1.3.6.1.4.1.3052.40.2.2.6 integer read-write
0-not sent, 1-sent
                         contact2TrapRepeat 1.3.6.1.4.1.3052.40.2.2.7 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps
                         contact2Severity 1.3.6.1.4.1.3052.40.2.2.8 integer read-write
1-minor 2-major 3-critical 4-severe 5-warning
                     contact3 1.3.6.1.4.1.3052.40.2.3
                         contact3Name 1.3.6.1.4.1.3052.40.2.3.1 displaystring read-write
Name for contact, up to 30 characters
                         contact3State 1.3.6.1.4.1.3052.40.2.3.2 integer read-only
Current State of Contact, 0-open 1-closed
                         contact3AlarmEnable 1.3.6.1.4.1.3052.40.2.3.3 integer read-write
0-no alarms 1-alarms enabled
                         contact3ActiveDirection 1.3.6.1.4.1.3052.40.2.3.4 integer read-write
0-alarm on open 1-alarm on closed
                         contact3Threshold 1.3.6.1.4.1.3052.40.2.3.5 integer read-write
Number of seconds must be in a state to be 'open' or 'closed'
                         contact3ReturnNormalTrap 1.3.6.1.4.1.3052.40.2.3.6 integer read-write
0-not sent, 1-sent
                         contact3TrapRepeat 1.3.6.1.4.1.3052.40.2.3.7 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps
                         contact3Severity 1.3.6.1.4.1.3052.40.2.3.8 integer read-write
1-minor 2-major 3-critical 4-severe 5-warning
                     contact4 1.3.6.1.4.1.3052.40.2.4
                         contact4Name 1.3.6.1.4.1.3052.40.2.4.1 displaystring read-write
Name for contact, up to 30 characters
                         contact4State 1.3.6.1.4.1.3052.40.2.4.2 integer read-only
Current State of Contact, 0-open 1-closed
                         contact4AlarmEnable 1.3.6.1.4.1.3052.40.2.4.3 integer read-write
0-no alarms 1-alarms enabled
                         contact4ActiveDirection 1.3.6.1.4.1.3052.40.2.4.4 integer read-write
0-alarm on open 1-alarm on closed
                         contact4Threshold 1.3.6.1.4.1.3052.40.2.4.5 integer read-write
Number of seconds must be in a state to be 'open' or 'closed'
                         contact4ReturnNormalTrap 1.3.6.1.4.1.3052.40.2.4.6 integer read-write
0-not sent, 1-sent
                         contact4TrapRepeat 1.3.6.1.4.1.3052.40.2.4.7 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps
                         contact4Severity 1.3.6.1.4.1.3052.40.2.4.8 integer read-write
1-minor 2-major 3-critical 4-severe 5-warning
                     contact5 1.3.6.1.4.1.3052.40.2.5
                         contact5Name 1.3.6.1.4.1.3052.40.2.5.1 displaystring read-write
Name for contact, up to 30 characters
                         contact5State 1.3.6.1.4.1.3052.40.2.5.2 integer read-only
Current State of Contact, 0-open 1-closed
                         contact5AlarmEnable 1.3.6.1.4.1.3052.40.2.5.3 integer read-write
0-no alarms 1-alarms enabled
                         contact5ActiveDirection 1.3.6.1.4.1.3052.40.2.5.4 integer read-write
0-alarm on open 1-alarm on closed
                         contact5Threshold 1.3.6.1.4.1.3052.40.2.5.5 integer read-write
Number of seconds must be in a state to be 'open' or 'closed'
                         contact5ReturnNormalTrap 1.3.6.1.4.1.3052.40.2.5.6 integer read-write
0-not sent, 1-sent
                         contact5TrapRepeat 1.3.6.1.4.1.3052.40.2.5.7 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps
                         contact5Severity 1.3.6.1.4.1.3052.40.2.5.8 integer read-write
1-minor 2-major 3-critical 4-severe 5-warning
                     contact6 1.3.6.1.4.1.3052.40.2.6
                         contact6Name 1.3.6.1.4.1.3052.40.2.6.1 displaystring read-write
Name for contact, up to 30 characters
                         contact6State 1.3.6.1.4.1.3052.40.2.6.2 integer read-only
Current State of Contact, 0-open 1-closed
                         contact6AlarmEnable 1.3.6.1.4.1.3052.40.2.6.3 integer read-write
0-no alarms 1-alarms enabled
                         contact6ActiveDirection 1.3.6.1.4.1.3052.40.2.6.4 integer read-write
0-alarm on open 1-alarm on closed
                         contact6Threshold 1.3.6.1.4.1.3052.40.2.6.5 integer read-write
Number of seconds must be in a state to be 'open' or 'closed'
                         contact6ReturnNormalTrap 1.3.6.1.4.1.3052.40.2.6.6 integer read-write
0-not sent, 1-sent
                         contact6TrapRepeat 1.3.6.1.4.1.3052.40.2.6.7 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps.
                         contact6Severity 1.3.6.1.4.1.3052.40.2.6.8 integer read-write
1-minor 2-major 3-critical 4-severe 5-warning
                     contact7 1.3.6.1.4.1.3052.40.2.7
                         contact7Name 1.3.6.1.4.1.3052.40.2.7.1 displaystring read-write
Name for contact, up to 30 characters
                         contact7State 1.3.6.1.4.1.3052.40.2.7.2 integer read-only
Current State of Contact, 0-open 1-closed
                         contact7AlarmEnable 1.3.6.1.4.1.3052.40.2.7.3 integer read-write
0-no alarms 1-alarms enabled
                         contact7ActiveDirection 1.3.6.1.4.1.3052.40.2.7.4 integer read-write
0-alarm on open 1-alarm on closed
                         contact7Threshold 1.3.6.1.4.1.3052.40.2.7.5 integer read-write
Number of seconds must be in a state to be 'open' or 'closed'
                         contact7ReturnNormalTrap 1.3.6.1.4.1.3052.40.2.7.6 integer read-write
0-not sent, 1-sent
                         contact7TrapRepeat 1.3.6.1.4.1.3052.40.2.7.7 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps
                         contact7Severity 1.3.6.1.4.1.3052.40.2.7.8 integer read-write
1-minor 2-major 3-critical 4-severe 5-warning
                     contact8 1.3.6.1.4.1.3052.40.2.8
                         contact8Name 1.3.6.1.4.1.3052.40.2.8.1 displaystring read-write
Name for contact, up to 30 characters
                         contact8State 1.3.6.1.4.1.3052.40.2.8.2 integer read-only
Current State of Contact, 0-open 1-closed
                         contact8AlarmEnable 1.3.6.1.4.1.3052.40.2.8.3 integer read-write
0-no alarms 1-alarms enabled
                         contact8ActiveDirection 1.3.6.1.4.1.3052.40.2.8.4 integer read-write
0-alarm on open 1-alarm on closed
                         contact8Threshold 1.3.6.1.4.1.3052.40.2.8.5 integer read-write
Number of seconds must be in a state to be 'open' or 'closed'
                         contact8ReturnNormalTrap 1.3.6.1.4.1.3052.40.2.8.6 integer read-write
0-not sent, 1-sent
                         contact8TrapRepeat 1.3.6.1.4.1.3052.40.2.8.7 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps
                         contact8Severity 1.3.6.1.4.1.3052.40.2.8.8 integer read-write
1-minor 2-major 3-critical 4-severe 5-warning
                     contact9 1.3.6.1.4.1.3052.40.2.9
                         contact9Name 1.3.6.1.4.1.3052.40.2.9.1 displaystring read-write
Name for contact, up to 30 characters
                         contact9State 1.3.6.1.4.1.3052.40.2.9.2 integer read-only
Current State of Contact, 0-open 1-closed
                         contact9AlarmEnable 1.3.6.1.4.1.3052.40.2.9.3 integer read-write
0-no alarms 1-alarms enabled
                         contact9ActiveDirection 1.3.6.1.4.1.3052.40.2.9.4 integer read-write
0-alarm on open 1-alarm on closed
                         contact9Threshold 1.3.6.1.4.1.3052.40.2.9.5 integer read-write
Number of seconds must be in a state to be 'open' or 'closed'
                         contact9ReturnNormalTrap 1.3.6.1.4.1.3052.40.2.9.6 integer read-write
0-not sent, 1-sent
                         contact9TrapRepeat 1.3.6.1.4.1.3052.40.2.9.7 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps
                         contact9Severity 1.3.6.1.4.1.3052.40.2.9.8 integer read-write
1-minor 2-major 3-critical 4-severe 5-warning
                 relays 1.3.6.1.4.1.3052.40.3
                     relay1 1.3.6.1.4.1.3052.40.3.1
                         relay1Name 1.3.6.1.4.1.3052.40.3.1.1 displaystring read-write
Name for relay, up to 30 characters
                         relay1CurrentState 1.3.6.1.4.1.3052.40.3.1.2 integer read-write
0-opened, 1-closed
                         relay1PowerupState 1.3.6.1.4.1.3052.40.3.1.3 integer read-write
0-opened, 1-closed
                     relay2 1.3.6.1.4.1.3052.40.3.2
                         relay2Name 1.3.6.1.4.1.3052.40.3.2.1 displaystring read-write
Name for relay, up to 30 characters
                         relay2CurrentState 1.3.6.1.4.1.3052.40.3.2.2 integer read-write
0-opened, 1-closed
                         relay2PowerupState 1.3.6.1.4.1.3052.40.3.2.3 integer read-write
0-opened, 1-closed
                 tempsensor 1.3.6.1.4.1.3052.40.4
                     tempValue 1.3.6.1.4.1.3052.40.4.1 integer read-only
Current Temperature Value, in C or F based on 1.3.6.1.4.1.3052.40.4.10
                     tempAlarmEnable 1.3.6.1.4.1.3052.40.4.2 integer read-write
0=alarms disabled, 1=alarms enabled
                     tempHighLevel 1.3.6.1.4.1.3052.40.4.3 integer read-write
Level at which the High alarm goes active
                     tempVeryHighLevel 1.3.6.1.4.1.3052.40.4.4 integer read-write
Level at which the Very High alarm goes active
                     tempLowLevel 1.3.6.1.4.1.3052.40.4.5 integer read-write
Level at which the Low alarm goes active
                     tempVeryLowLevel 1.3.6.1.4.1.3052.40.4.6 integer read-write
Level at which the Very Low alarm goes active
                     tempAlarmThreshold 1.3.6.1.4.1.3052.40.4.7 integer read-write
Seconds must be in a range to be an alarm
                     tempReturnNormalTrap 1.3.6.1.4.1.3052.40.4.8 integer read-write
0-not sent, 1-send trap on return to normal range
                     tempTrapRepeat 1.3.6.1.4.1.3052.40.4.9 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps.
                     tempMode 1.3.6.1.4.1.3052.40.4.10 integer read-write
0=all temp readings and levels in degrees F, 1=in degrees C
                     tempHighSeverity 1.3.6.1.4.1.3052.40.4.11 integer read-write
High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                     tempVeryHighSeverity 1.3.6.1.4.1.3052.40.4.12 integer read-write
Very High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                     tempLowSeverity 1.3.6.1.4.1.3052.40.4.13 integer read-write
Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                     tempVeryLowSeverity 1.3.6.1.4.1.3052.40.4.14 integer read-write
Very Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                     tempName 1.3.6.1.4.1.3052.40.4.15 displaystring read-write
Name for temperature sensor, up to 30 characters
                 humiditysensor 1.3.6.1.4.1.3052.40.5
                     humidityValue 1.3.6.1.4.1.3052.40.5.1 integer read-only
Current Relative Humidity Value (0-100%)
                     humidityAlarmEnable 1.3.6.1.4.1.3052.40.5.2 integer read-write
0=alarms disabled, 1=alarms enabled
                     humidityHighLevel 1.3.6.1.4.1.3052.40.5.3 integer read-write
Level at which the High alarm goes active
                     humidityVeryHighLevel 1.3.6.1.4.1.3052.40.5.4 integer read-write
Level at which the Very High alarm goes active
                     humidityLowLevel 1.3.6.1.4.1.3052.40.5.5 integer read-write
Level at which the Low alarm goes active
                     humidityVeryLowLevel 1.3.6.1.4.1.3052.40.5.6 integer read-write
Level at which the Very Low alarm goes active
                     humidityAlarmThreshold 1.3.6.1.4.1.3052.40.5.7 integer read-write
Seconds must be in a range to be an alarm
                     humidityReturnNormalTrap 1.3.6.1.4.1.3052.40.5.8 integer read-write
0-not sent, 1-send trap on return to normal range
                     humidityTrapRepeat 1.3.6.1.4.1.3052.40.5.9 integer read-write
0-no repeats. 1-255 number of minutes between repeats of alarm traps.
                     humidityHighSeverity 1.3.6.1.4.1.3052.40.5.10 integer read-write
High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                     humidityVeryHighSeverity 1.3.6.1.4.1.3052.40.5.11 integer read-write
Very High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                     humidityLowSeverity 1.3.6.1.4.1.3052.40.5.12 integer read-write
Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                     humidityVeryLowSeverity 1.3.6.1.4.1.3052.40.5.13 integer read-write
Very Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                     humidityName 1.3.6.1.4.1.3052.40.5.14 displaystring read-write
Name for humidity sensor, up to 30 characters
                 passthrough 1.3.6.1.4.1.3052.40.6
                     ptNeedPassword 1.3.6.1.4.1.3052.40.6.1 integer read-write
0-no 1-yes, is password required for passthrough connection.
                     ptSayLoginText 1.3.6.1.4.1.3052.40.6.2 integer read-write
0-no 1-yes, is passthrough login text displayed on connection.
                     ptLoginText 1.3.6.1.4.1.3052.40.6.3 displaystring read-write
0-24 char string which may be displayed on socket connection. Requires that ptSayLoginText be enabled to display this string.
                     ptSaySiteID 1.3.6.1.4.1.3052.40.6.4 integer read-write
0-no 1-yes, is SiteID displayed on pass through connection.
                     ptUsername 1.3.6.1.4.1.3052.40.6.5 displaystring read-write
0-16 char string for Username used in serial passthrough connections
                     ptPassword 1.3.6.1.4.1.3052.40.6.6 displaystring read-write
0-16 char string for Password used in serial passthrough connections
                     ptTimeout 1.3.6.1.4.1.3052.40.6.7 integer read-write
number of minutes (1-255) of idle activity (both directions) which causes disconnect. 0-never
                     ptEscChar 1.3.6.1.4.1.3052.40.6.8 integer read-write
ASCII character code (e.g, Escape=27) which if entered on the tcp port three times in a row causes disconnect. 0-none
                     ptLfstripToPort 1.3.6.1.4.1.3052.40.6.9 integer read-write
0-no 1-yes linefeed characters received on TCP connection are removed from stream to serial port
                     ptLfstripFromPort 1.3.6.1.4.1.3052.40.6.10 integer read-write
0-no 1-yes linefeed characters received on serial port are removed from stream to TCP connection
                     ptSerialBaudrate 1.3.6.1.4.1.3052.40.6.11 integer read-write
300 600 1200 2400 4800 9600 19200 baud are allowed values
                     ptSerialWordlength 1.3.6.1.4.1.3052.40.6.12 integer read-write
7 or 8 bit word selection
                     ptSerialParity 1.3.6.1.4.1.3052.40.6.13 displaystring read-write
N E O are allowed values for parity (none, even, odd) [a single-character string]
                     ptTCPPortnumber 1.3.6.1.4.1.3052.40.6.14 integer read-write
IP port number for passthrough connection (range 1024-65534)
                 ftp 1.3.6.1.4.1.3052.40.7
                     ftpUsername 1.3.6.1.4.1.3052.40.7.1 displaystring read-write
0-16 char string for Username used in ftp server for updates
                     ftpPassword 1.3.6.1.4.1.3052.40.7.2 displaystring read-write
0-16 char string for Password used in ftp server for updates
                 analog 1.3.6.1.4.1.3052.40.8
                     analog1 1.3.6.1.4.1.3052.40.8.1
                         analog1Value 1.3.6.1.4.1.3052.40.8.1.1 integer read-only
Value of current analog reading, in 1/100 volt, +- 9999 range
                         analog1AlarmEnable 1.3.6.1.4.1.3052.40.8.1.2 integer read-write
0=no alarms, 1=send alarms
                         analog1HighLevel 1.3.6.1.4.1.3052.40.8.1.3 integer read-write
Level at which the High alarm goes active
                         analog1VeryHighLevel 1.3.6.1.4.1.3052.40.8.1.4 integer read-write
Level at which the Very High alarm goes active
                         analog1LowLevel 1.3.6.1.4.1.3052.40.8.1.5 integer read-write
Level at which the Low alarm goes active
                         analog1VeryLowLevel 1.3.6.1.4.1.3052.40.8.1.6 integer read-write
Level at which the Very Low alarm goes active
                         analog1AlarmThreshold 1.3.6.1.4.1.3052.40.8.1.7 integer read-write
Seconds must be in a range to be an alarm
                         analog1ReturnNormalTrap 1.3.6.1.4.1.3052.40.8.1.8 integer read-write
0-not sent, 1-send trap on return to normal range
                         analog1TrapRepeat 1.3.6.1.4.1.3052.40.8.1.9 integer read-write
0-no repeats else number of minutes between repeats of trap
                         analog1HighSeverity 1.3.6.1.4.1.3052.40.8.1.10 integer read-write
High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                         analog1VeryHighSeverity 1.3.6.1.4.1.3052.40.8.1.11 integer read-write
Very High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                         analog1LowSeverity 1.3.6.1.4.1.3052.40.8.1.12 integer read-write
Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                         analog1VeryLowSeverity 1.3.6.1.4.1.3052.40.8.1.13 integer read-write
Very Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                         analog1Name 1.3.6.1.4.1.3052.40.8.1.14 displaystring read-write
Name for analog sensor 1, up to 30 characters
                     analog2 1.3.6.1.4.1.3052.40.8.2
                         analog2Value 1.3.6.1.4.1.3052.40.8.2.1 integer read-only
Value of current analog reading, in 1/100 volt, +- 9999 range
                         analog2AlarmEnable 1.3.6.1.4.1.3052.40.8.2.2 integer read-write
0=no alarms, 1=send alarms
                         analog2HighLevel 1.3.6.1.4.1.3052.40.8.2.3 integer read-write
Level at which the High alarm goes active
                         analog2VeryHighLevel 1.3.6.1.4.1.3052.40.8.2.4 integer read-write
Level at which the Very High alarm goes active
                         analog2LowLevel 1.3.6.1.4.1.3052.40.8.2.5 integer read-write
Level at which the Low alarm goes active
                         analog2VeryLowLevel 1.3.6.1.4.1.3052.40.8.2.6 integer read-write
Level at which the Very Low alarm goes active
                         analog2AlarmThreshold 1.3.6.1.4.1.3052.40.8.2.7 integer read-write
Seconds must be in a range to be an alarm
                         analog2ReturnNormalTrap 1.3.6.1.4.1.3052.40.8.2.8 integer read-write
0-not sent, 1-send trap on return to normal range
                         analog2TrapRepeat 1.3.6.1.4.1.3052.40.8.2.9 integer read-write
0-no repeats else number of minutes between repeats of trap
                         analog2HighSeverity 1.3.6.1.4.1.3052.40.8.2.10 integer read-write
High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                         analog2VeryHighSeverity 1.3.6.1.4.1.3052.40.8.2.11 integer read-write
Very High Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                         analog2LowSeverity 1.3.6.1.4.1.3052.40.8.2.12 integer read-write
Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                         analog2VeryLowSeverity 1.3.6.1.4.1.3052.40.8.2.13 integer read-write
Very Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warning
                         analog2Name 1.3.6.1.4.1.3052.40.8.2.14 displaystring read-write
Name for analog sensor 2, up to 30 characters
                 eventSensorStatus 1.3.6.1.4.1.3052.40.10
                       esPointTable 1.3.6.1.4.1.3052.40.10.1 no-access
This table organizes 4 basic attributes of points. A point is a particular sensor on an EventSensor (e.g., temperature, humidity, contact closure 2, relay 5, etc.). The 4 point attributes are its name, whether it's in its event state, the point's value as a number and its value as a string. Points are referenced by a point index. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point).
                           esPointEntry 1.3.6.1.4.1.3052.40.10.1.1 no-access
Entry for EventSensor point table
                               esIndexES 1.3.6.1.4.1.3052.40.10.1.1.1 integer read-only
The part of the point index that refers to an EventSensor. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). This object's allowable values are 1 through 4, which refer to attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor.
                               esIndexPC 1.3.6.1.4.1.3052.40.10.1.1.2 integer read-only
The part of the point index that refers to point class. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). The values for this object are: 1=temperature sensor 2=contact closure 3=humidity sensor 4=noise sensor 5=analog input 6=relay
                               esIndexPoint 1.3.6.1.4.1.3052.40.10.1.1.3 integer read-only
The part of the point index that delineates which sensor on the EventSensor. So this combined with esIndexPC (Point Class or type) and esIndexES (which EventSensor) uniquely defines each point (sensor or relay) attached to a unit. For example, if esIndexES is 3, esIndexPC is 1 and esIndexPoint is 4 then this is the Fourth Temperature Sensor on EventSensor number 3.
                               esPointName 1.3.6.1.4.1.3052.40.10.1.1.4 displaystring read-write
The name of the point on an EventSensor. For example, 'AC temp' (in the case of the temperature sensor on an EventSensor). There can be multiple points of the same point class on an EventSensor (e.g., 8 contact closures) and multiple sensor classes on an EventSensor (e.g., temperature, contact closure, humidity). If the point referenced by a given point index is solitary (e.g., temperature sensor, because there can be only one on an EventSensor), then this object reads as ''. Setting this object for solitary point indices sets the EventSensor name only. On the other hand, if a given point is among other points of the same point class on an EventSensor, then this object reads as ''. Setting this object for these NON- solitary point indices sets the sensor name only - not the EventSensor name.
                               esPointInEventState 1.3.6.1.4.1.3052.40.10.1.1.5 integer read-write
A number referring to the event state of a point on an EventSensor. This number can have different meanings depending on the point class. If the point class is temperature, humidity, or analog input, then the values of this object are: 1=very low 2=low 3=normal 4=high 5=very high For contact closures and relays the values of this object are: 1=point in event state 2=point in normal state For any point class and any point, if the event state is undefined, then the value of this object is 0. For any point class except relay, this object is read-only. For relays, setting this object to 1 puts the relay into its open state. Setting it to 2 puts the relay into its closed state.
                               esPointValueInt 1.3.6.1.4.1.3052.40.10.1.1.6 integer read-write
A number referring to the value of a point on an EventSensor. If the point class is temperature, then this object is the temperature in its configured scale (default is Fahrenheit). If the point class is contact closure or relay, then this object is either 0 (open) or 1 (closed). If the point class is humidity, then this object is the percent relative humidity. If the point class is analog input, then this object is the signed input value in tenths of the configured units. For any point class except relay, this object is read-only. For relays, setting this object to 1 closes the relay, while setting it to 0 opens it. This works regardless of the control mode of the relay.
                               esPointValueStr 1.3.6.1.4.1.3052.40.10.1.1.7 displaystring read-only
A string referring to the value of a point on an EventSensor. For contact closures and relays this object is either 'Open' or 'Closed'. For temperature and humidity point classes, this object is the string representation of the esPointValueInt object. For temperature, 'C' or 'F' is including in the string to indicate scale. For analog inputs, this object is the string representation of the plus/minus input in volts.
                 eventSensorConfig 1.3.6.1.4.1.3052.40.11
                       esNumberEventSensors 1.3.6.1.4.1.3052.40.11.1 integer read-only
The number of EventSensors recognized by the SL10 Range: 0-4
                       esTable 1.3.6.1.4.1.3052.40.11.2 no-access
The table of what EventSensors are attached to the unit
                           esEntry 1.3.6.1.4.1.3052.40.11.2.1 no-access
Table entry for EventSensor table
                               esIndex 1.3.6.1.4.1.3052.40.11.2.1.1 integer read-only
This number refers to an EventSensor; it has the same meaning as the esIndexES object (see above), except that this object is used only within the esTable branch. This object's allowable values are 1 through 4, which refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time.
                               esID 1.3.6.1.4.1.3052.40.11.2.1.2 displaystring read-only
The factory-assigned ID of the EventSensor
                               esNumberTempSensors 1.3.6.1.4.1.3052.40.11.2.1.3 integer read-only
The number of temperature sensors on the EventSensor
                               esTempReportingMode 1.3.6.1.4.1.3052.40.11.2.1.4 displaystring read-only
Description of how temperature values should be interpreted.
                               esNumberCCs 1.3.6.1.4.1.3052.40.11.2.1.5 integer read-only
The number of contact closures on the EventSensor.
                               esCCReportingMode 1.3.6.1.4.1.3052.40.11.2.1.6 displaystring read-only
Description of how CC values should be interpreted.
                               esNumberHumidSensors 1.3.6.1.4.1.3052.40.11.2.1.7 integer read-only
The number of humidity sensors on the EventSensor.
                               esHumidReportingMode 1.3.6.1.4.1.3052.40.11.2.1.8 displaystring read-only
Description of how humidity sensor values should be interpreted.
                               esNumberNoiseSensors 1.3.6.1.4.1.3052.40.11.2.1.9 integer read-only
The number of noise sensors on the EventSensor.
                               esNoiseReportingMode 1.3.6.1.4.1.3052.40.11.2.1.10 displaystring read-only
Description of how noise sensor values should be interpreted.
                               esNumberAirflowSensors 1.3.6.1.4.1.3052.40.11.2.1.11 integer read-only
The number of airflow sensors on the EventSensor.
                               esAirflowReportingMode 1.3.6.1.4.1.3052.40.11.2.1.12 displaystring read-only
Description of how airflow sensor values should be interpreted.
                               esNumberAnalog 1.3.6.1.4.1.3052.40.11.2.1.13 integer read-only
The number of analog inputs on the EventSensor.
                               esAnalogReportingMode 1.3.6.1.4.1.3052.40.11.2.1.14 displaystring read-only
Description of how analog input values should be interpreted.
                               esNumberRelayOutputs 1.3.6.1.4.1.3052.40.11.2.1.15 integer read-only
The number of relay outputs on the EventSensor
                               esRelayReportingMode 1.3.6.1.4.1.3052.40.11.2.1.16 displaystring read-only
Description of how relay output values should be interpreted.
                 techsupport 1.3.6.1.4.1.3052.40.99
                       techsupportIPAddress 1.3.6.1.4.1.3052.40.99.1 ipaddress read-write
May read or Set IP Address, takes effect on restart
                       techsupportNetMask 1.3.6.1.4.1.3052.40.99.2 ipaddress read-write
May read or Set NetMask, takes effect on restart
                       techsupportRouter 1.3.6.1.4.1.3052.40.99.3 ipaddress read-write
May read or Set Router IP Address, takes effect on restart
                       techsupportRestart 1.3.6.1.4.1.3052.40.99.4 integer read-write
Reads as 0, any Write resets unit so new IP, Netmask, Router may be used
                       techsupportSerialNumber 1.3.6.1.4.1.3052.40.99.5 displaystring read-write
Read/Set Serial Number, up to 8-char text string reported as 1.1
                       techsupportBoxTemp 1.3.6.1.4.1.3052.40.99.6 integer read-only
Estimate of inside-the-box temp in degrees C, for heater testing
                       techsupportHeaterState 1.3.6.1.4.1.3052.40.99.7 integer read-only
0-off 1-on (acutal heater pin on/off, heat may not be 100% duty cycle)
                       techsupportPSVolts 1.3.6.1.4.1.3052.40.99.8 integer read-only
estimate of power supply input voltage (only valid on 48V build)
                 mibend 1.3.6.1.4.1.3052.40.100
                         mibendObject 1.3.6.1.4.1.3052.40.100.1 integer read-only
An object after all active mib items, to help some managers compile
                   contact1ActiveTrap 1.3.6.1.4.1.3052.400.20001
Sent to show Contact 1 is in the alarm state
                   contact2ActiveTrap 1.3.6.1.4.1.3052.400.20002
Sent to show Contact 2 is in the alarm state
                   contact3ActiveTrap 1.3.6.1.4.1.3052.400.20003
Sent to show Contact 3 is in the alarm state
                   contact4ActiveTrap 1.3.6.1.4.1.3052.400.20004
Sent to show Contact 4 is in the alarm state
                   contact5ActiveTrap 1.3.6.1.4.1.3052.400.20005
Sent to show Contact 5 is in the alarm state
                   contact6ActiveTrap 1.3.6.1.4.1.3052.400.20006
Sent to show Contact 6 is in the alarm state
                   contact7ActiveTrap 1.3.6.1.4.1.3052.400.20007
Sent to show Contact 7 is in the alarm state
                   contact8ActiveTrap 1.3.6.1.4.1.3052.400.20008
Sent to show Contact 8 is in the alarm state
                   contact9ActiveTrap 1.3.6.1.4.1.3052.400.20009
Send to show Contact 9 is in the alarm state
                   tempHighTrap 1.3.6.1.4.1.3052.400.20010
Sent to show Temp exceeded High Temp Threshold
                   tempVeryHighTrap 1.3.6.1.4.1.3052.400.20011
Sent to show Temp exceeded Very High Temp Threshold
                   tempLowTrap 1.3.6.1.4.1.3052.400.20012
Sent to show Temp went below Low Temp Threshold
                   tempVeryLowTrap 1.3.6.1.4.1.3052.400.20013
Sent to show Temp went below Very Low Temp Threshold
                   humidityHighTrap 1.3.6.1.4.1.3052.400.20020
Sent to show humidity exceeded High humidity Threshold
                   humidityVeryHighTrap 1.3.6.1.4.1.3052.400.20021
Sent to show humidity exceeded Very High humidity Threshold
                   humidityLowTrap 1.3.6.1.4.1.3052.400.20022
Sent to show humidity went below Low humidity Threshold
                   humidityVeryLowTrap 1.3.6.1.4.1.3052.400.20023
Sent to show humidity went below Very Low humidity Threshold
                   analog1HighTrap 1.3.6.1.4.1.3052.400.20030
Sent to show analog1 exceeded High analog1 Threshold
                   analog1VeryHighTrap 1.3.6.1.4.1.3052.400.20031
Sent to show analog1 exceeded Very High analog1 Threshold
                   analog1LowTrap 1.3.6.1.4.1.3052.400.20032
Sent to show analog1 went below Low analog1 Threshold
                   analog1VeryLowTrap 1.3.6.1.4.1.3052.400.20033
Sent to show analog1 went below Very Low analog1 Threshold
                   analog2HighTrap 1.3.6.1.4.1.3052.400.20040
Sent to show analog2 exceeded High analog2 Threshold
                   analog2VeryHighTrap 1.3.6.1.4.1.3052.400.20041
Sent to show analog2 exceeded Very High analog2 Threshold
                   analog2LowTrap 1.3.6.1.4.1.3052.400.20042
Sent to show analog2 went below Low analog2 Threshold
                   analog2VeryLowTrap 1.3.6.1.4.1.3052.400.20043
Sent to show analog2 went below Very Low analog2 Threshold
                   contactESActiveTrap 1.3.6.1.4.1.3052.400.20101
Sent to show EventSensor contact is in the alarm state
                   tempESHighTrap 1.3.6.1.4.1.3052.400.20110
Sent to show Temp exceeded High Threshold on an EventSensor
                   tempESVeryHighTrap 1.3.6.1.4.1.3052.400.20111
Sent to show Temp exceeded Very High Threshold on an EventSensor
                   tempESLowTrap 1.3.6.1.4.1.3052.400.20112
Sent to show Temp went below Low Threshold on an EventSensor
                   tempESVeryLowTrap 1.3.6.1.4.1.3052.400.20113
Sent to show Temp went below Very Low Threshold on an EventSensor
                   humidityESHighTrap 1.3.6.1.4.1.3052.400.20120
Sent to show humidity exceeded High Threshold on an EventSensor
                   humidityESVeryHighTrap 1.3.6.1.4.1.3052.400.20121
Sent to show humidity exceeded Very High Threshold on an EventSensor
                   humidityESLowTrap 1.3.6.1.4.1.3052.400.20122
Sent to show humidity went below Low Threshold on an EventSensor
                   humidityESVeryLowTrap 1.3.6.1.4.1.3052.400.20123
Sent to show humidity went below Very Low Threshold on an EventSensor
                   voltageESHighTrap 1.3.6.1.4.1.3052.400.20130
Sent to show voltage exceeded High Threshold on an EventSensor
                   voltageESVeryHighTrap 1.3.6.1.4.1.3052.400.20131
Sent to show voltage exceeded Very High Threshold on an EventSensor
                   voltageESLowTrap 1.3.6.1.4.1.3052.400.20132
Sent to show voltage went below Low Threshold on an EventSensor
                   voltageESVeryLowTrap 1.3.6.1.4.1.3052.400.20133
Sent to show voltage went below Very Low Threshold on an EventSensor
                   contact1NormalTrap 1.3.6.1.4.1.3052.400.21001
Sent to show Contact 1 is in the normal state
                   contact2NormalTrap 1.3.6.1.4.1.3052.400.21002
Sent to show Contact 2 is in the normal state
                   contact3NormalTrap 1.3.6.1.4.1.3052.400.21003
Sent to show Contact 3 is in the normal state
                   contact4NormalTrap 1.3.6.1.4.1.3052.400.21004
Sent to show Contact 4 is in the normal state
                   contact5NormalTrap 1.3.6.1.4.1.3052.400.21005
Sent to show Contact 5 is in the normal state
                   contact6NormalTrap 1.3.6.1.4.1.3052.400.21006
Sent to show Contact 6 is in the normal state
                   contact7NormalTrap 1.3.6.1.4.1.3052.400.21007
Sent to show Contact 7 is in the normal state
                   contact8NormalTrap 1.3.6.1.4.1.3052.400.21008
Sent to show Contact 8 is in the normal state
                   contact9NormalTrap 1.3.6.1.4.1.3052.400.21009
Send to show Contact 9 is in the normal state
                   tempNormalTrap 1.3.6.1.4.1.3052.400.21010
Sent to show Temp went back to Normal range
                   humidityNormalTrap 1.3.6.1.4.1.3052.400.21020
Sent to show Humidity went back to Normal range
                   analog1NormalTrap 1.3.6.1.4.1.3052.400.21030
Sent to show analog1 went back to Normal range
                   analog2NormalTrap 1.3.6.1.4.1.3052.400.21040
Sent to show analog2 went back to Normal range
                   contactESNormalTrap 1.3.6.1.4.1.3052.400.21101
Send to show EventSensor contact has returned to normal state
                   tempESNormalTrap 1.3.6.1.4.1.3052.400.21110
Sent to show EventSensor Temp went back to Normal range
                   humidityESNormalTrap 1.3.6.1.4.1.3052.400.21120
Sent to show EventSensor Humidity went back to Normal range
                   voltageESNormalTrap 1.3.6.1.4.1.3052.400.21130
Sent to show EventSensor voltage went back to Normal range
                   testTrap 1.3.6.1.4.1.3052.400.22000