SL-TESTS-MIB: View SNMP OID List / Download MIB

VENDOR: PACKETLIGHT NETWORKS LTD.


 Home MIB: SL-TESTS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 slTests 1.3.6.1.4.1.4515.1.3.13
       slTestsIfLoop 1.3.6.1.4.1.4515.1.3.13.1
           slTestsIfLoopTable 1.3.6.1.4.1.4515.1.3.13.1.1
The port loopback test table. This table controls the port loopback tests.
               slTestsIfLoopEntry 1.3.6.1.4.1.4515.1.3.13.1.1.1
This entry is used to operate an port loopback test.
                   slTestsIfLoopIfIndex 1.3.6.1.4.1.4515.1.3.13.1.1.1.1
The Interface Index of the port that should be loopped back.
                   slTestsIfLoopDuration 1.3.6.1.4.1.4515.1.3.13.1.1.1.2
The test duration in 1/10 Sec. The maximum allowed duration is 1 hour. After this time the port configuration returns to its original setting and the Agent automatically deletes the entry from the table.
                   slTestsIfLoopStatus 1.3.6.1.4.1.4515.1.3.13.1.1.1.3
This variable is used to start or stop a loopback test. In order to start a test the NMS should set the value to start(1). If the test mode is toggle, the NMS should stop the test by setting the value to stop(2). In the case of prbs test, after the test has stopped, if the test fails the value of the status shall be fail(3).
                   slTestsIfLoopType 1.3.6.1.4.1.4515.1.3.13.1.1.1.5
The loopback type: facility The received signal at this interface is looped back out through the corresponding transmitter in the return direction. terminal The signal that is about to be transmitted is connected to the associated incoming receiver. prbs send and recieve prbs pattern. otnPrbs send and receive OTN prbs
                   slTestsIfLoopMode 1.3.6.1.4.1.4515.1.3.13.1.1.1.6
The loopback mode: timeout In this mode the duration of the loopback is determined by the slTestsIfLoopDuration object. toggle In this mode the loopback should be toggled explicitly by the user.
                   slTestsIfLoopErrors 1.3.6.1.4.1.4515.1.3.13.1.1.1.7
The prbs errors are counted only of the test succeeded.
                   slTestsIfLoopResult 1.3.6.1.4.1.4515.1.3.13.1.1.1.8
This variable is used for prbs test result indication.
                   slTestsIfLoopPassedSeconds 1.3.6.1.4.1.4515.1.3.13.1.1.1.9
Number of seconds passed since the test started.
       slTestsTraps 1.3.6.1.4.1.4515.1.3.13.2
           slTestsTraps0 1.3.6.1.4.1.4515.1.3.13.2.0
           slTestsTrapsLoopbackActive 1.3.6.1.4.1.4515.1.3.13.2.1
The Loopback is active Yes/No.