Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
slEdfa | 1.3.6.1.4.1.4515.1.9 | |||
edfaConfig | 1.3.6.1.4.1.4515.1.9.1 | |||
edfaConfigTable | 1.3.6.1.4.1.4515.1.9.1.1 |
The EDFA configuration table. |
||
1.3.6.1.4.1.4515.1.9.1.1.1 |
An entry in the EDFA interface configuration table. The index to this table is the same as the an ifIndex. |
|||
edfaIfIndex | 1.3.6.1.4.1.4515.1.9.1.1.1.1 |
The amplifier interface index. |
||
edfaPumpTemp | 1.3.6.1.4.1.4515.1.9.1.1.1.2 |
The pump temperture (in Kelvin). |
||
edfaRxPower | 1.3.6.1.4.1.4515.1.9.1.1.1.3 |
The measured Rx Power. The value is specified in tenth of Dbm units increments, starting from -30.0 dbm (e.g. value 0 means -30.0 dbm). |
||
edfaPumpAdminStatus | 1.3.6.1.4.1.4515.1.9.1.1.1.4 |
The desired state of the laser. The restart(3) state indicates that the edfa pump should be restarted. The restart(3) is not a state, thus it is not kept in the configuration file. |
||
edfaPumpOperStatus | 1.3.6.1.4.1.4515.1.9.1.1.1.5 |
The current operational state of the laser. If edfaPumpAdminStatus is down(2) then edfaPumpOperStatus should be down(2). If edfaPumpAdminStatus is changed to up(1) then edfaPumpOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic; it should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state. The operational status is equal to restart(3) if the edfa pump is still in restart process. |
||
edfaStatus | 1.3.6.1.4.1.4515.1.9.1.1.1.6 |
This variable indicates the Line Status of the Edfa module. The edfaStatus is a bit map represented as a sum, therefore, it can represent multiple failures (alarms) simultaneously. edfaNoAlarm must be set if and only if no other flag is set. The various bit positions are: 1 edfaNoAlarm No alarm present 2 edfaPumpTemperuture Pump temperatur is out-of-bound 4 edfaPumpWavelength Pump wavelength is out-of-bound 8 edfaHwFail Pump HW failure 16 edfaRvcSignalDetect Loss of input signal 32 edfaPumpPower Pump power is out-of-bound 64 edfaRcvPower Rx Power is out-of-bound 128 edfaTemprature Edfa temperature is out-of-bound 256 edfaEyeSafty Eye safety alarm (available only in eye-safety mode) 512 edafGainFlatness Gain flatness alarm 1024 edfaXmtPower Tx Power is out-of-bound 2048 edfaGain Edfa Gain is out-of-bound 4096 edfaEol Pump End Of Life |
||
edfaVoa | 1.3.6.1.4.1.4515.1.9.1.1.1.7 |
The computed VOA output attenuation specified in 0.1 dB units. From 0.0 to +15.0 dB. |
||
edfaAutomaticMode | 1.3.6.1.4.1.4515.1.9.1.1.1.8 |
Defines the Edfa automatic mode. If equals TRUE, the Edfa control mode should selected automaticaly. Otherwise it should be selected manualy. |
||
edfaAdminControlMode | 1.3.6.1.4.1.4515.1.9.1.1.1.9 |
Configure the Edfa control mode. This object may be set only when edfaAtomaticMode is FALSE. |
||
edfaOperControlMode | 1.3.6.1.4.1.4515.1.9.1.1.1.10 |
The current Edfa control mode. Initialy the Edfa starts in APC mode. The AGC mode is used only when selected manualy or after transient input power change. |
||
edfaAdminGain | 1.3.6.1.4.1.4515.1.9.1.1.1.11 |
The required Edfa Gain value given in 0.1 dB units. This value may be configured only when the edfa automatic mode is FALSE and the edfa control mode is Agc. |
||
edfaOperGain | 1.3.6.1.4.1.4515.1.9.1.1.1.12 |
The actual Edfa Gain value given in 0.1 dB units. Value range starts with 0.0 dbm |
||
edfaAdminOutputPower | 1.3.6.1.4.1.4515.1.9.1.1.1.13 |
The required Edfa output power value given in 0.1 dBm units. The range starts with -30.0 dBm. This value may be configured only when the edfa control mode is Apc. |
||
edfaOperOutputPower | 1.3.6.1.4.1.4515.1.9.1.1.1.14 |
The actual Edfa output power value specified in 0.1 dBm units. Valid valuse are in the range of 0.0 dBm upto +15.0 dBm. |
||
edfaChannelsNumber | 1.3.6.1.4.1.4515.1.9.1.1.1.15 |
The number of optical channels on this signal. |
||
edfaTotalChannelsNumber | 1.3.6.1.4.1.4515.1.9.1.1.1.16 |
The total number of optical channels on this fiber. |
||
edfaEyeSafetyMode | 1.3.6.1.4.1.4515.1.9.1.1.1.17 |
When in Eye-Safety mode the edfa reduces the laser power budget down to safe level upon detection of an output fiber cut. |
||
edfaShutDownLipEnable | 1.3.6.1.4.1.4515.1.9.1.1.1.18 |
EDFA shout-down on LIP (Loss of signal) - enable/disable. |
||
edfaAutoPowerUpLipEnable | 1.3.6.1.4.1.4515.1.9.1.1.1.19 |
EDFA automatic power up (after signal returns) - enable/disable. |
||
edfaMaxGain | 1.3.6.1.4.1.4515.1.9.1.1.1.20 |
The EDFA max gain is determined by the result of the VER command. Legal values: gainUnknown(1) gain14dbm(2) - Booster/Inline, (-2)-14dBm output power, gain (-5)-22dB gain17dbm(3) - Booster/Inline, (-2)-17dBm output power, gain (-5)-22dB gain20dbm(4) - Booster/Inline, (-2)-20dBm output power, gain (-5)-22dB gain23dbm(5) - Booster/Inline, 5-23dBm output power, gain (-5)-22dB, 16 channels gain18dbmPreAmp8Ch(6) - Preamp (-18)-5dBm output power, fixed gain 18dB gain18dbmPreAmp16ChRed(7) - Preamp (-18)-5dBm output power, fixed gain 18dB gain18dbmPreAmp16ChBlue(8)- Preamp (-18)-0dBm output power, fixed gain 18dB gain23dbmGain10(9) - Booster/Inline, 23dBm output power with fixed gain of 10dB, 32 channels |
||
edfaGainInFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.21 |
Lower input gain range of the edfa in units of 0.1 db. |
||
edfaGainInTo | 1.3.6.1.4.1.4515.1.9.1.1.1.22 |
Upper input gain range of the edfa in units of 0.1 db. |
||
edfaGainOutFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.23 |
Lower output gain range of the edfa in units of 0.1 db. |
||
edfaGainOutTo | 1.3.6.1.4.1.4515.1.9.1.1.1.24 |
Upper output gain range of the edfa in units of 0.1 db. |
||
edfaPowerInFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.25 |
Lower input power range of the edfa in units of 0.1 dbm. |
||
edfaPowerInTo | 1.3.6.1.4.1.4515.1.9.1.1.1.26 |
Upper input power range of the edfa in units of 0.1 dbm. |
||
edfaPowerOutFrom | 1.3.6.1.4.1.4515.1.9.1.1.1.27 |
Lower output power range of the edfa in units of 0.1 dbm. |
||
edfaPowerOutTo | 1.3.6.1.4.1.4515.1.9.1.1.1.28 |
Upper output power range of the edfa in units of 0.1 dbm. |
||
edfaFromChannel | 1.3.6.1.4.1.4515.1.9.1.1.1.29 |
The first channel number supported by the edfa; 0 to ignore. |
||
edfaToChannel | 1.3.6.1.4.1.4515.1.9.1.1.1.30 |
The last channel number supported by the edfa; 0 to ignore. |
||
edfaOscChannel | 1.3.6.1.4.1.4515.1.9.1.1.1.31 |
The wavelenght of the optical supervisory channel e.g. 1510, 1490. |
||
edfaRedBlueType | 1.3.6.1.4.1.4515.1.9.1.1.1.32 |
The type of the edaf. |
||
edfaRole | 1.3.6.1.4.1.4515.1.9.1.1.1.33 |
The role of the edaf. |
||
edfaFreeDescription | 1.3.6.1.4.1.4515.1.9.1.1.1.34 |
A free text with additional edfa information. |
||
edfaConfigSafetyThreshold | 1.3.6.1.4.1.4515.1.9.1.1.1.35 |
The Eye Safety threshold level specified in dBm units. The value given in 0.1 dBm units. The range starts with -50.0 dBm. |
||
edfaTraps | 1.3.6.1.4.1.4515.1.9.2 | |||
edfaTraps0 | 1.3.6.1.4.1.4515.1.9.2.0 |