SL-CHASSIS-MIB: View SNMP OID List / Download MIB
VENDOR: PACKETLIGHT NETWORKS LTD.
Home | MIB: SL-CHASSIS-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
slChassis | 1.3.6.1.4.1.4515.1.3.18 |
This MIB module describes the Multi-Chassis information |
||
slChassisInfo | 1.3.6.1.4.1.4515.1.3.18.1 | |||
slChassisInfoNodeSlotId | 1.3.6.1.4.1.4515.1.3.18.1.1 |
The slot ID of the node. This number is assigned to the node before it is a part of the chassis. Slot ID should be assigned also to the GNE nodes. The Slot ID should be unique in the chassis. |
||
slChassisInfoNodeRole | 1.3.6.1.4.1.4515.1.3.18.1.2 |
The role of the node. gneNode - for Master or Backup chassis GNE node. internalSlotNode - for non gne node. none - the node is in a simple chassis |
||
slChassisInfoLanVrrpIp | 1.3.6.1.4.1.4515.1.3.18.1.3 |
The VRRP ip of the node on the LAN interface. |
||
slChassisInfoOscVrrpIp | 1.3.6.1.4.1.4515.1.3.18.1.4 |
The VRRP ip of the node on the OSC interface. |
||
slChassisInfoTopology | 1.3.6.1.4.1.4515.1.3.18.1.5 |
The topology mode of the multichassis: osc - the management use the LAN IP of the GNE and VRRP. lan - the management use the OSC IP of the GNE and VRRP. simple - no GNE to the chassis. Used for display only |
||
slChassisInfoVrrpEnable | 1.3.6.1.4.1.4515.1.3.18.1.6 |
Enable/Disable the activation of the VRRP protocol by the GNE |
||
slChassisSlot | 1.3.6.1.4.1.4515.1.3.18.2 | |||
slChassisSlotTable | 1.3.6.1.4.1.4515.1.3.18.2.1 |
This table contains the chassis slots. |
||
1.3.6.1.4.1.4515.1.3.18.2.1.1 |
An entry in the Chassis Slot table. |
|||
slChassisSlotId | 1.3.6.1.4.1.4515.1.3.18.2.1.1.1 |
The slot ID of the node. |
||
slChassisSlotRole | 1.3.6.1.4.1.4515.1.3.18.2.1.1.2 |
The role of the node. gneNode - for Master or Backup chassis GNE node. internalNode - for non gne node |
||
slChassisSlotInternalIp | 1.3.6.1.4.1.4515.1.3.18.2.1.1.3 |
The internal ip of the node. This address is used to identify the node and not for management access. |
||
slChassisSlotProductType | 1.3.6.1.4.1.4515.1.3.18.2.1.1.4 |
The sysObjectID of the node. |
||
slChassisSlotSysName | 1.3.6.1.4.1.4515.1.3.18.2.1.1.5 |
The SysName of the node |
||
slChassisSlotSnmp161Port | 1.3.6.1.4.1.4515.1.3.18.2.1.1.6 |
The SNMP Gte/Set port of the node. |
||
slChassisSlotSnmp162MinPort | 1.3.6.1.4.1.4515.1.3.18.2.1.1.7 |
The minimal SNMP Trap port of the node. |
||
slChassisSlotSnmp162MaxPort | 1.3.6.1.4.1.4515.1.3.18.2.1.1.8 |
The maximal SNMP Trap port of the node. |
||
slChassisSlotHttpPort | 1.3.6.1.4.1.4515.1.3.18.2.1.1.9 |
The HTTP port of the node. |
||
slChassisSlotTelnetPort | 1.3.6.1.4.1.4515.1.3.18.2.1.1.10 |
The Telnet port of the node. |
||
slChassisSlotFtpPort | 1.3.6.1.4.1.4515.1.3.18.2.1.1.12 |
The Ftp port of the node. |
||
slChassisSlotTL1Port | 1.3.6.1.4.1.4515.1.3.18.2.1.1.13 |
The TL1 port of the node. |
||
slChassisSlotPingIdentifier | 1.3.6.1.4.1.4515.1.3.18.2.1.1.14 |
The ping identifier of the node. |
||
slChassisSlotHttpsPort | 1.3.6.1.4.1.4515.1.3.18.2.1.1.15 |
The HTTPS port of the node. |
||
slChassisSlotSshPort | 1.3.6.1.4.1.4515.1.3.18.2.1.1.16 |
The SSH port of the node. |
||
slChassisSlotSTL1Port | 1.3.6.1.4.1.4515.1.3.18.2.1.1.17 |
The TL1 over SSH port of the node. |