SIXNET-MIB: View SNMP OID List / Download MIB

VENDOR: RED LION CONTROLS (SIXNET)


 Home MIB: SIXNET-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 sixnet 1.3.6.1.4.1.20540
             sixnetObjects 1.3.6.1.4.1.20540.1
             sixnetDevices 1.3.6.1.4.1.20540.2
                 et9ms 1.3.6.1.4.1.20540.2.1
                     et9msScalars 1.3.6.1.4.1.20540.2.1.1
                         p1status 1.3.6.1.4.1.20540.2.1.1.1
The current operational state of P1 power input.
                         p2status 1.3.6.1.4.1.20540.2.1.1.2
The current operational state of P2 power input.
                         oKstatus 1.3.6.1.4.1.20540.2.1.1.3
The current operational state of OK relay output.
                         serialNumber 1.3.6.1.4.1.20540.2.1.1.4
The serial number of the device.
                         sxid 1.3.6.1.4.1.20540.2.1.1.5
The SXID of the device.
                         firmwareRevision 1.3.6.1.4.1.20540.2.1.1.6
The firmware revision.
                         fromPLCstatus 1.3.6.1.4.1.20540.2.1.1.7
The current operational state of From PLC input.
                         sxAllRingsGood 1.3.6.1.4.1.20540.2.1.1.8
True if all rings configured for this switch are complete.
                         sxAllRingNeighborsGood 1.3.6.1.4.1.20540.2.1.1.9
True if all neighbors in all configured rings for this switch are complete.
                     etmsTables 1.3.6.1.4.1.20540.2.1.2
                         pppTable 1.3.6.1.4.1.20540.2.1.2.1
A list of interface entries.
                             pppEntry 1.3.6.1.4.1.20540.2.1.2.1.1
An entry containing management information applicable to a particular interface.
                                 pppifIndex 1.3.6.1.4.1.20540.2.1.2.1.1.1
A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entitys network management system to the next re- initialization.
                                 pppifOperStatus 1.3.6.1.4.1.20540.2.1.2.1.1.2
The current operational state of the interface.
                     etmsTest 1.3.6.1.4.1.20540.2.1.9999
                               portTestTable 1.3.6.1.4.1.20540.2.1.9999.1
A list of interface entries.
                                   portTestEntry 1.3.6.1.4.1.20540.2.1.9999.1.1
An entry containing management information applicable to a particular interface.
                                       testifIndex 1.3.6.1.4.1.20540.2.1.9999.1.1.1
A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entitys network management system to the next re- initialization.
                                       ifAdminSpeed 1.3.6.1.4.1.20540.2.1.9999.1.1.2
Force port speed (in megabits/sec)
                                       ifAdminPower 1.3.6.1.4.1.20540.2.1.9999.1.1.3
The PHYs PwrDown bit. ifAdminPower in the down(2) state indicates that the PHY control regsiter, bit 11 is 1 (Power Down). ifAdminPower in the up(1) date indicates that the PHY control register, bit 11 is 0 (Normal operation)
                               ledTestTrigger 1.3.6.1.4.1.20540.2.1.9999.2
Trigger LED test
                               sixnetTestConfig 1.3.6.1.4.1.20540.2.1.9999.3
                                   sixnetConfigState 1.3.6.1.4.1.20540.2.1.9999.3.1
Trigger LED test
                                   sixnetConfigResult 1.3.6.1.4.1.20540.2.1.9999.3.2
Result of configuration. Valid only when configState is done.
                                   sixnetConfigServer 1.3.6.1.4.1.20540.2.1.9999.3.3
The address of the configuration server. Typically an IP address but might be a FQDN.
                                   sixnetConfigFile 1.3.6.1.4.1.20540.2.1.9999.3.4
The file to retrieve and process.
             sixnetNotificationPrefix 1.3.6.1.4.1.20540.4
                 sixnetNotifications 1.3.6.1.4.1.20540.4.0
                 sixnetNotificationObjects 1.3.6.1.4.1.20540.4.1
             sixnetConformance 1.3.6.1.4.1.20540.5
                 sixnetCompliances 1.3.6.1.4.1.20540.5.1
                 sixnetGroups 1.3.6.1.4.1.20540.5.2
             sixnetExperimental 1.3.6.1.4.1.20540.9999
                       sixnetPlaypen 1.3.6.1.4.1.20540.9999.9999