SITEBOSS-350-STD-MIB: View SNMP OID List / Download MIB

VENDOR: ASENTRIA CORPORATION


 Home MIB: SITEBOSS-350-STD-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 s350 1.3.6.1.4.1.3052.18
MIB module for managing Asentria SiteBoss 350
       s350Notifications 1.3.6.1.4.1.3052.18.0
           s350StockContactClosureTrap 1.3.6.1.4.1.3052.18.0.110
A stock contact closure trap is issued when a contact closure event happens.
           s350StockTempTrap 1.3.6.1.4.1.3052.18.0.120
A stock temperature trap is issued when a temperature event happens.
           s350StockHumidityTrap 1.3.6.1.4.1.3052.18.0.130
A stock humidity trap is issued when a humidity event happens.
           s350StockAnalogTrap 1.3.6.1.4.1.3052.18.0.140
A stock analog trap is issued when an analog sensor event happens.
           s350StockOutputTrap 1.3.6.1.4.1.3052.18.0.150
A stock output trap is issued when an output event happens. That is, depending on the configuration, when an output changes state for any reason, this trap will be sent.
           s350StockPDCurrentTrap 1.3.6.1.4.1.3052.18.0.180
A stock analog trap is issued when a power distribution current event happens.
           s350StockPDVoltageTrap 1.3.6.1.4.1.3052.18.0.190
A stock analog trap is issued when a power distribution voltage event happens.
           s350StockPDFuseTrap 1.3.6.1.4.1.3052.18.0.210
A stock analog trap is issued when a power distribution fuse event happens.
           s350StockSchedTrap 1.3.6.1.4.1.3052.18.0.506
The stock scheduled alarm trap is issued when the current time reaches the scheduled alarm time.
           s350StockImmediateTrap 1.3.6.1.4.1.3052.18.0.507
The stock immediate alarm trap is issued when the user enters the DOTRAP command.
           s350StockCTSTrap 1.3.6.1.4.1.3052.18.0.510
A stock CTS trap is issued when an RS-232 CTS event happens.
           s350CPEDownTrap 1.3.6.1.4.1.3052.18.0.511
A stock CPE Down trap is issued when a CPE Down event happens.
           s350FuelSensorDisconnectTrap 1.3.6.1.4.1.3052.18.0.515
A stock Fuel Sensor Disconnect trap is issued when a Fuel Sensor Disconnect or Connect (Return to Normal) event happens.
           s350FuelSensorVolumeTrap 1.3.6.1.4.1.3052.18.0.519
A stock Fuel Sensor Volume trap is issued when a Fuel Sensor Volume event happens
           s350ACPowerMonitorAvgVoltageTrap 1.3.6.1.4.1.3052.18.0.520
A stock AC power monitor average voltage trap is issued when an AC power monitor average voltage event happens.
           s350ACPowerMonitorAvgCurrentTrap 1.3.6.1.4.1.3052.18.0.521
A stock AC power monitor average current trap is issued when an AC power monitor average current event happens.
           s350ACPowerMonitorFrequencyTrap 1.3.6.1.4.1.3052.18.0.522
A stock AC power monitor frequency trap is issued when an AC power monitor frequency event happens.
           s350ACPowerMonitorTRPTrap 1.3.6.1.4.1.3052.18.0.523
A stock AC power monitor TRP (total real power) trap is issued when an AC power monitor TRP event happens.
           s350ACPowerMonitorDisconnectTrap 1.3.6.1.4.1.3052.18.0.524
A stock AC power monitor disconnect trap is issued when an AC power monitor disconnect event happens.
           s350StockScriptTrap 1.3.6.1.4.1.3052.18.0.526
A stock script trap is issued when a script triggers an event via a_lib.PostEvent() called with no trap number (or this trap number) specified.
           s350FuelSensorVolumeSuddenChangeTrap 1.3.6.1.4.1.3052.18.0.527
A stock Fuel Sensor Volume Sudden Change trap is issued when a Fuel Sensor Volume Sudden Change event happens
           s350FuelSensorVolumeSlowChangeTrap 1.3.6.1.4.1.3052.18.0.528
A stock Fuel Sensor Volume Slow Change trap is issued when a Fuel Sensor Volume Slow Change event happens
           s350BattMonStringTemperatureTrap 1.3.6.1.4.1.3052.18.0.530
A stock Battery Monitor String Temperature trap is issued when a Battery Monitor String Temperature event happens.
           s350BattMonStringDiffTemperatureTrap 1.3.6.1.4.1.3052.18.0.531
A stock Battery Monitor String Differential Temperature trap is issued when a Battery Monitor String Differential Temperature event happens.
           s350BattMonStringVoltageTrap 1.3.6.1.4.1.3052.18.0.532
A stock Battery Monitor String Voltage trap is issued when a Battery Monitor String Voltage event happens.
           s350BattMonStringChargeLevelTrap 1.3.6.1.4.1.3052.18.0.533
A stock Battery Monitor String Charge Level trap is issued when a Battery Monitor String Charge Level event happens.
           s350BattMonStringChargingCurrentTrap 1.3.6.1.4.1.3052.18.0.534
A stock Battery Monitor String Charging Current trap is issued when a Battery Monitor String Charging Current event happens.
           s350BattMonStringDischargingCurrentTrap 1.3.6.1.4.1.3052.18.0.535
A stock Battery Monitor String Discharging Current trap is issued when a Battery Monitor String Discharging Current event happens.
           s350GeneratorNonStartTrap 1.3.6.1.4.1.3052.18.0.536
A stock Generator Non-start trap is issued when the unit commands the generator to start as part of the generator exercising feature, and the generator fails to register as started after 30 seconds (as detected by CC generator running detection).
           s350BattMonStringDifferentialVoltageTrap 1.3.6.1.4.1.3052.18.0.537
A stock Battery Monitor String Differential Voltage trap is issued when a Battery Monitor String Differential Voltage event happens.
           s350BattMonStringJarHealthTrap 1.3.6.1.4.1.3052.18.0.538
A stock Battery Monitor String Jar Health trap is issued when a Battery Monitor String Jar Health event happens.
           s350CameraTrap 1.3.6.1.4.1.3052.18.0.539
A stock camera trap is issued when a camera event happens.
           s350ACTotalPowerFactorTrap 1.3.6.1.4.1.3052.18.0.540
A stock AC power monitor total power factor trap is issued when an AC power monitor total power factor event happens.
           s350LocationTrap 1.3.6.1.4.1.3052.18.0.541
A stock location trap is issued when a location event happens.
           s350SleepTrap 1.3.6.1.4.1.3052.18.0.542
A stock sleep trap is issued when a sleep event happens.
           s350ResetTrap 1.3.6.1.4.1.3052.18.0.543
A stock reset trap is issued when a reset event happens.
           s350FuelSensorLevelsAutoAdjustTrap 1.3.6.1.4.1.3052.18.0.544
A stock fuel sensor levels auto-adjust trap is issued when a fuel sensor levels auto-adjust event happens.
           s350AccessControlTrap 1.3.6.1.4.1.3052.18.0.547
A stock access control trap is issued when an access control device management event happens.
           s350UserTrap1000 1.3.6.1.4.1.3052.18.0.1000
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1000.
           s350UserTrap1001 1.3.6.1.4.1.3052.18.0.1001
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1001.
           s350UserTrap1002 1.3.6.1.4.1.3052.18.0.1002
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1002.
           s350UserTrap1003 1.3.6.1.4.1.3052.18.0.1003
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1003.
           s350UserTrap1004 1.3.6.1.4.1.3052.18.0.1004
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1004.
           s350UserTrap1005 1.3.6.1.4.1.3052.18.0.1005
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1005.
           s350UserTrap1006 1.3.6.1.4.1.3052.18.0.1006
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1006.
           s350UserTrap1007 1.3.6.1.4.1.3052.18.0.1007
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1007.
           s350UserTrap1008 1.3.6.1.4.1.3052.18.0.1008
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1008.
           s350UserTrap1009 1.3.6.1.4.1.3052.18.0.1009
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1009.
           s350UserTrap1010 1.3.6.1.4.1.3052.18.0.1010
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1010.
           s350UserTrap1011 1.3.6.1.4.1.3052.18.0.1011
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1011.
           s350UserTrap1012 1.3.6.1.4.1.3052.18.0.1012
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1012.
           s350UserTrap1013 1.3.6.1.4.1.3052.18.0.1013
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1013.
           s350UserTrap1014 1.3.6.1.4.1.3052.18.0.1014
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1014.
           s350UserTrap1015 1.3.6.1.4.1.3052.18.0.1015
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1015.
           s350UserTrap1016 1.3.6.1.4.1.3052.18.0.1016
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1016.
           s350UserTrap1017 1.3.6.1.4.1.3052.18.0.1017
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1017.
           s350UserTrap1018 1.3.6.1.4.1.3052.18.0.1018
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1018.
           s350UserTrap1019 1.3.6.1.4.1.3052.18.0.1019
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1019.
           s350UserTrap1020 1.3.6.1.4.1.3052.18.0.1020
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1020.
           s350UserTrap1021 1.3.6.1.4.1.3052.18.0.1021
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1021.
           s350UserTrap1022 1.3.6.1.4.1.3052.18.0.1022
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1022.
           s350UserTrap1023 1.3.6.1.4.1.3052.18.0.1023
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1023.
           s350UserTrap1024 1.3.6.1.4.1.3052.18.0.1024
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1024.
           s350UserTrap1025 1.3.6.1.4.1.3052.18.0.1025
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1025.
           s350UserTrap1026 1.3.6.1.4.1.3052.18.0.1026
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1026.
           s350UserTrap1027 1.3.6.1.4.1.3052.18.0.1027
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1027.
           s350UserTrap1028 1.3.6.1.4.1.3052.18.0.1028
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1028.
           s350UserTrap1029 1.3.6.1.4.1.3052.18.0.1029
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1029.
           s350UserTrap1030 1.3.6.1.4.1.3052.18.0.1030
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1030.
           s350UserTrap1031 1.3.6.1.4.1.3052.18.0.1031
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1031.
           s350UserTrap1032 1.3.6.1.4.1.3052.18.0.1032
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1032.
           s350UserTrap1033 1.3.6.1.4.1.3052.18.0.1033
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1033.
           s350UserTrap1034 1.3.6.1.4.1.3052.18.0.1034
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1034.
           s350UserTrap1035 1.3.6.1.4.1.3052.18.0.1035
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1035.
           s350UserTrap1036 1.3.6.1.4.1.3052.18.0.1036
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1036.
           s350UserTrap1037 1.3.6.1.4.1.3052.18.0.1037
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1037.
           s350UserTrap1038 1.3.6.1.4.1.3052.18.0.1038
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1038.
           s350UserTrap1039 1.3.6.1.4.1.3052.18.0.1039
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1039.
           s350UserTrap1040 1.3.6.1.4.1.3052.18.0.1040
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1040.
           s350UserTrap1041 1.3.6.1.4.1.3052.18.0.1041
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1041.
           s350UserTrap1042 1.3.6.1.4.1.3052.18.0.1042
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1042.
           s350UserTrap1043 1.3.6.1.4.1.3052.18.0.1043
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1043.
           s350UserTrap1044 1.3.6.1.4.1.3052.18.0.1044
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1044.
           s350UserTrap1045 1.3.6.1.4.1.3052.18.0.1045
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1045.
           s350UserTrap1046 1.3.6.1.4.1.3052.18.0.1046
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1046.
           s350UserTrap1047 1.3.6.1.4.1.3052.18.0.1047
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1047.
           s350UserTrap1048 1.3.6.1.4.1.3052.18.0.1048
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1048.
           s350UserTrap1049 1.3.6.1.4.1.3052.18.0.1049
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1049.
           s350UserTrap1050 1.3.6.1.4.1.3052.18.0.1050
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1050.
           s350UserTrap1051 1.3.6.1.4.1.3052.18.0.1051
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1051.
           s350UserTrap1052 1.3.6.1.4.1.3052.18.0.1052
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1052.
           s350UserTrap1053 1.3.6.1.4.1.3052.18.0.1053
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1053.
           s350UserTrap1054 1.3.6.1.4.1.3052.18.0.1054
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1054.
           s350UserTrap1055 1.3.6.1.4.1.3052.18.0.1055
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1055.
           s350UserTrap1056 1.3.6.1.4.1.3052.18.0.1056
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1056.
           s350UserTrap1057 1.3.6.1.4.1.3052.18.0.1057
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1057.
           s350UserTrap1058 1.3.6.1.4.1.3052.18.0.1058
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1058.
           s350UserTrap1059 1.3.6.1.4.1.3052.18.0.1059
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1059.
           s350UserTrap1060 1.3.6.1.4.1.3052.18.0.1060
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1060.
           s350UserTrap1061 1.3.6.1.4.1.3052.18.0.1061
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1061.
           s350UserTrap1062 1.3.6.1.4.1.3052.18.0.1062
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1062.
           s350UserTrap1063 1.3.6.1.4.1.3052.18.0.1063
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1063.
           s350UserTrap1064 1.3.6.1.4.1.3052.18.0.1064
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1064.
           s350UserTrap1065 1.3.6.1.4.1.3052.18.0.1065
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1065.
           s350UserTrap1066 1.3.6.1.4.1.3052.18.0.1066
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1066.
           s350UserTrap1067 1.3.6.1.4.1.3052.18.0.1067
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1067.
           s350UserTrap1068 1.3.6.1.4.1.3052.18.0.1068
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1068.
           s350UserTrap1069 1.3.6.1.4.1.3052.18.0.1069
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1069.
           s350UserTrap1070 1.3.6.1.4.1.3052.18.0.1070
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1070.
           s350UserTrap1071 1.3.6.1.4.1.3052.18.0.1071
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1071.
           s350UserTrap1072 1.3.6.1.4.1.3052.18.0.1072
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1072.
           s350UserTrap1073 1.3.6.1.4.1.3052.18.0.1073
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1073.
           s350UserTrap1074 1.3.6.1.4.1.3052.18.0.1074
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1074.
           s350UserTrap1075 1.3.6.1.4.1.3052.18.0.1075
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1075.
           s350UserTrap1076 1.3.6.1.4.1.3052.18.0.1076
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1076.
           s350UserTrap1077 1.3.6.1.4.1.3052.18.0.1077
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1077.
           s350UserTrap1078 1.3.6.1.4.1.3052.18.0.1078
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1078.
           s350UserTrap1079 1.3.6.1.4.1.3052.18.0.1079
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1079.
           s350UserTrap1080 1.3.6.1.4.1.3052.18.0.1080
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1080.
           s350UserTrap1081 1.3.6.1.4.1.3052.18.0.1081
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1081.
           s350UserTrap1082 1.3.6.1.4.1.3052.18.0.1082
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1082.
           s350UserTrap1083 1.3.6.1.4.1.3052.18.0.1083
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1083.
           s350UserTrap1084 1.3.6.1.4.1.3052.18.0.1084
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1084.
           s350UserTrap1085 1.3.6.1.4.1.3052.18.0.1085
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1085.
           s350UserTrap1086 1.3.6.1.4.1.3052.18.0.1086
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1086.
           s350UserTrap1087 1.3.6.1.4.1.3052.18.0.1087
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1087.
           s350UserTrap1088 1.3.6.1.4.1.3052.18.0.1088
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1088.
           s350UserTrap1089 1.3.6.1.4.1.3052.18.0.1089
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1089.
           s350UserTrap1090 1.3.6.1.4.1.3052.18.0.1090
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1090.
           s350UserTrap1091 1.3.6.1.4.1.3052.18.0.1091
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1091.
           s350UserTrap1092 1.3.6.1.4.1.3052.18.0.1092
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1092.
           s350UserTrap1093 1.3.6.1.4.1.3052.18.0.1093
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1093.
           s350UserTrap1094 1.3.6.1.4.1.3052.18.0.1094
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1094.
           s350UserTrap1095 1.3.6.1.4.1.3052.18.0.1095
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1095.
           s350UserTrap1096 1.3.6.1.4.1.3052.18.0.1096
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1096.
           s350UserTrap1097 1.3.6.1.4.1.3052.18.0.1097
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1097.
           s350UserTrap1098 1.3.6.1.4.1.3052.18.0.1098
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1098.
           s350UserTrap1099 1.3.6.1.4.1.3052.18.0.1099
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1099.
           s350UserTrap1100 1.3.6.1.4.1.3052.18.0.1100
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1100.
           s350UserTrap1101 1.3.6.1.4.1.3052.18.0.1101
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1101.
           s350UserTrap1102 1.3.6.1.4.1.3052.18.0.1102
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1102.
           s350UserTrap1103 1.3.6.1.4.1.3052.18.0.1103
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1103.
           s350UserTrap1104 1.3.6.1.4.1.3052.18.0.1104
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1104.
           s350UserTrap1105 1.3.6.1.4.1.3052.18.0.1105
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1105.
           s350UserTrap1106 1.3.6.1.4.1.3052.18.0.1106
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1106.
           s350UserTrap1107 1.3.6.1.4.1.3052.18.0.1107
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1107.
           s350UserTrap1108 1.3.6.1.4.1.3052.18.0.1108
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1108.
           s350UserTrap1109 1.3.6.1.4.1.3052.18.0.1109
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1109.
           s350UserTrap1110 1.3.6.1.4.1.3052.18.0.1110
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1110.
           s350UserTrap1111 1.3.6.1.4.1.3052.18.0.1111
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1111.
           s350UserTrap1112 1.3.6.1.4.1.3052.18.0.1112
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1112.
           s350UserTrap1113 1.3.6.1.4.1.3052.18.0.1113
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1113.
           s350UserTrap1114 1.3.6.1.4.1.3052.18.0.1114
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1114.
           s350UserTrap1115 1.3.6.1.4.1.3052.18.0.1115
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1115.
           s350UserTrap1116 1.3.6.1.4.1.3052.18.0.1116
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1116.
           s350UserTrap1117 1.3.6.1.4.1.3052.18.0.1117
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1117.
           s350UserTrap1118 1.3.6.1.4.1.3052.18.0.1118
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1118.
           s350UserTrap1119 1.3.6.1.4.1.3052.18.0.1119
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1119.
           s350UserTrap1120 1.3.6.1.4.1.3052.18.0.1120
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1120.
           s350UserTrap1121 1.3.6.1.4.1.3052.18.0.1121
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1121.
           s350UserTrap1122 1.3.6.1.4.1.3052.18.0.1122
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1122.
           s350UserTrap1123 1.3.6.1.4.1.3052.18.0.1123
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1123.
           s350UserTrap1124 1.3.6.1.4.1.3052.18.0.1124
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1124.
           s350UserTrap1125 1.3.6.1.4.1.3052.18.0.1125
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1125.
           s350UserTrap1126 1.3.6.1.4.1.3052.18.0.1126
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1126.
           s350UserTrap1127 1.3.6.1.4.1.3052.18.0.1127
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1127.
           s350UserTrap1128 1.3.6.1.4.1.3052.18.0.1128
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1128.
           s350UserTrap1129 1.3.6.1.4.1.3052.18.0.1129
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1129.
           s350UserTrap1130 1.3.6.1.4.1.3052.18.0.1130
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1130.
           s350UserTrap1131 1.3.6.1.4.1.3052.18.0.1131
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1131.
           s350UserTrap1132 1.3.6.1.4.1.3052.18.0.1132
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1132.
           s350UserTrap1133 1.3.6.1.4.1.3052.18.0.1133
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1133.
           s350UserTrap1134 1.3.6.1.4.1.3052.18.0.1134
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1134.
           s350UserTrap1135 1.3.6.1.4.1.3052.18.0.1135
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1135.
           s350UserTrap1136 1.3.6.1.4.1.3052.18.0.1136
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1136.
           s350UserTrap1137 1.3.6.1.4.1.3052.18.0.1137
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1137.
           s350UserTrap1138 1.3.6.1.4.1.3052.18.0.1138
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1138.
           s350UserTrap1139 1.3.6.1.4.1.3052.18.0.1139
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1139.
           s350UserTrap1140 1.3.6.1.4.1.3052.18.0.1140
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1140.
           s350UserTrap1141 1.3.6.1.4.1.3052.18.0.1141
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1141.
           s350UserTrap1142 1.3.6.1.4.1.3052.18.0.1142
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1142.
           s350UserTrap1143 1.3.6.1.4.1.3052.18.0.1143
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1143.
           s350UserTrap1144 1.3.6.1.4.1.3052.18.0.1144
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1144.
           s350UserTrap1145 1.3.6.1.4.1.3052.18.0.1145
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1145.
           s350UserTrap1146 1.3.6.1.4.1.3052.18.0.1146
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1146.
           s350UserTrap1147 1.3.6.1.4.1.3052.18.0.1147
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1147.
           s350UserTrap1148 1.3.6.1.4.1.3052.18.0.1148
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1148.
           s350UserTrap1149 1.3.6.1.4.1.3052.18.0.1149
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1149.
           s350UserTrap1150 1.3.6.1.4.1.3052.18.0.1150
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1150.
           s350UserTrap1151 1.3.6.1.4.1.3052.18.0.1151
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1151.
           s350UserTrap1152 1.3.6.1.4.1.3052.18.0.1152
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1152.
           s350UserTrap1153 1.3.6.1.4.1.3052.18.0.1153
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1153.
           s350UserTrap1154 1.3.6.1.4.1.3052.18.0.1154
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1154.
           s350UserTrap1155 1.3.6.1.4.1.3052.18.0.1155
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1155.
           s350UserTrap1156 1.3.6.1.4.1.3052.18.0.1156
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1156.
           s350UserTrap1157 1.3.6.1.4.1.3052.18.0.1157
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1157.
           s350UserTrap1158 1.3.6.1.4.1.3052.18.0.1158
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1158.
           s350UserTrap1159 1.3.6.1.4.1.3052.18.0.1159
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1159.
           s350UserTrap1160 1.3.6.1.4.1.3052.18.0.1160
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1160.
           s350UserTrap1161 1.3.6.1.4.1.3052.18.0.1161
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1161.
           s350UserTrap1162 1.3.6.1.4.1.3052.18.0.1162
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1162.
           s350UserTrap1163 1.3.6.1.4.1.3052.18.0.1163
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1163.
           s350UserTrap1164 1.3.6.1.4.1.3052.18.0.1164
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1164.
           s350UserTrap1165 1.3.6.1.4.1.3052.18.0.1165
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1165.
           s350UserTrap1166 1.3.6.1.4.1.3052.18.0.1166
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1166.
           s350UserTrap1167 1.3.6.1.4.1.3052.18.0.1167
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1167.
           s350UserTrap1168 1.3.6.1.4.1.3052.18.0.1168
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1168.
           s350UserTrap1169 1.3.6.1.4.1.3052.18.0.1169
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1169.
           s350UserTrap1170 1.3.6.1.4.1.3052.18.0.1170
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1170.
           s350UserTrap1171 1.3.6.1.4.1.3052.18.0.1171
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1171.
           s350UserTrap1172 1.3.6.1.4.1.3052.18.0.1172
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1172.
           s350UserTrap1173 1.3.6.1.4.1.3052.18.0.1173
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1173.
           s350UserTrap1174 1.3.6.1.4.1.3052.18.0.1174
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1174.
           s350UserTrap1175 1.3.6.1.4.1.3052.18.0.1175
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1175.
           s350UserTrap1176 1.3.6.1.4.1.3052.18.0.1176
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1176.
           s350UserTrap1177 1.3.6.1.4.1.3052.18.0.1177
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1177.
           s350UserTrap1178 1.3.6.1.4.1.3052.18.0.1178
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1178.
           s350UserTrap1179 1.3.6.1.4.1.3052.18.0.1179
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1179.
           s350UserTrap1180 1.3.6.1.4.1.3052.18.0.1180
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1180.
           s350UserTrap1181 1.3.6.1.4.1.3052.18.0.1181
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1181.
           s350UserTrap1182 1.3.6.1.4.1.3052.18.0.1182
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1182.
           s350UserTrap1183 1.3.6.1.4.1.3052.18.0.1183
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1183.
           s350UserTrap1184 1.3.6.1.4.1.3052.18.0.1184
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1184.
           s350UserTrap1185 1.3.6.1.4.1.3052.18.0.1185
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1185.
           s350UserTrap1186 1.3.6.1.4.1.3052.18.0.1186
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1186.
           s350UserTrap1187 1.3.6.1.4.1.3052.18.0.1187
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1187.
           s350UserTrap1188 1.3.6.1.4.1.3052.18.0.1188
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1188.
           s350UserTrap1189 1.3.6.1.4.1.3052.18.0.1189
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1189.
           s350UserTrap1190 1.3.6.1.4.1.3052.18.0.1190
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1190.
           s350UserTrap1191 1.3.6.1.4.1.3052.18.0.1191
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1191.
           s350UserTrap1192 1.3.6.1.4.1.3052.18.0.1192
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1192.
           s350UserTrap1193 1.3.6.1.4.1.3052.18.0.1193
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1193.
           s350UserTrap1194 1.3.6.1.4.1.3052.18.0.1194
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1194.
           s350UserTrap1195 1.3.6.1.4.1.3052.18.0.1195
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1195.
           s350UserTrap1196 1.3.6.1.4.1.3052.18.0.1196
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1196.
           s350UserTrap1197 1.3.6.1.4.1.3052.18.0.1197
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1197.
           s350UserTrap1198 1.3.6.1.4.1.3052.18.0.1198
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1198.
           s350UserTrap1199 1.3.6.1.4.1.3052.18.0.1199
This user-defined trap is issued when an event happens that causes a trap with specific trap type 1199.
       status 1.3.6.1.4.1.3052.18.1
           eventSensorStatus 1.3.6.1.4.1.3052.18.1.1
               esPointTable 1.3.6.1.4.1.3052.18.1.1.1 no-access
This table organizes 4 basic attributes of points. A point is a particular sensor on an EventSensor (e.g., temperature, humidity, contact closure 2, output 5, etc.). The 4 point attributes are its name, whether it's in its event state, the point's value as a number and its value as a string. Points are referenced by a point index. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point).
                   esPointEntry 1.3.6.1.4.1.3052.18.1.1.1.1 no-access
Entry for EventSensor point table
                       esIndexES 1.3.6.1.4.1.3052.18.1.1.1.1.1 integer32 read-only
The part of the point index that refers to an EventSensor. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor.
                       esIndexPC 1.3.6.1.4.1.3052.18.1.1.1.1.2 integer32 read-only
The part of the point index that refers to point class. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). The values for this object are: 1=temperature sensor 2=contact closure 3=humidity sensor 4=noise sensor 5=analog input 6=output (relay output or power output)
                       esIndexPoint 1.3.6.1.4.1.3052.18.1.1.1.1.3 integer32 read-only
The part of the point index that delineates which sensor on the EventSensor. So this combined with esIndexPC (Point Class or type) and esIndexES (which EventSensor) uniquely defines each point (sensor or output) attached to a unit. For example, if esIndexES is 3, esIndexPC is 1 and esIndexPoint is 4 then this is the Fourth Temperature Sensor on EventSensor number 3.
                       esPointName 1.3.6.1.4.1.3052.18.1.1.1.1.4 displaystring read-write
The name of the point on an EventSensor. For example, 'AC temp' (in the case of the temperature sensor on an EventSensor). There can be multiple points of the same point class on an EventSensor (e.g., 8 contact closures) and multiple sensor classes on an EventSensor (e.g., temperature, contact closure, humidity). If the point referenced by a given point index is solitary (e.g., temperature sensor, because there can be only one on an EventSensor), then this object reads as ''. Setting this object for solitary point indices sets the EventSensor name only. On the other hand, if a given point is among other points of the same point class on an EventSensor, then this object reads as ''. Setting this object for these NON- solitary point indices sets the sensor name only - not the EventSensor name.
                       esPointInEventState 1.3.6.1.4.1.3052.18.1.1.1.1.5 integer32 read-write
A number referring to the event state of a point on an EventSensor. This number can have different meanings depending on the point class. If the point class is temperature, humidity, or analog input, then the values of this object are: 1=very low 2=low 3=normal 4=high 5=very high For contact closures the values of this object are: 1=point in event state 2=point in normal state For outputs the values of this object is the numeric code for the logical state of the output: 1 or 2. The logical state of the output is either active/inactive for relay outputs or on/off for power outputs. The logical state of the output has different nomenclature depending on the type of the output (relay output or power output): 1=active (for relay output) or on (for power output) 2=inactive (for relay output) or off (for power output) This is not necessarily representative of physical state of the output. Physical state is energized/de-energized, for both relay and power outputs. For relay outputs, the active logical state corresponds to either the energized physical state or the de-energized physical state depending on how the relay output is configured. For power outputs, the on logical state always corresponds to the energized physical state. For any point class and any point, if the event state is undefined, then the value of this object is 0. For any point class except output, this object is read-only. For outputs, setting this object to 1 puts the output into its active logical state. Setting this object to 2 puts the output into its inactive logical state. Setting this object to any value greater than 2 puts the output into its active logical state for that many seconds (up to 3600), after which time it puts the output into its inactive logical state.
                       esPointValueInt 1.3.6.1.4.1.3052.18.1.1.1.1.6 integer32 read-write
A read-only number referring to the value of a point on an EventSensor. If the point class is temperature, then this object is the temperature in its configured scale (default is Fahrenheit). If the point class is contact closure, then this object is either 0 (open) or 1 (closed). If the point class is humidity, then this object is the percent relative humidity. If the point class is analog input, then this object is the signed input value in tenths of the configured units. If the point class is an output, then this object is the numeric code for the physical state of the output. 0=de-energized 1=energized This object cannot be used to control the output, i.e, change its logical or physical state (instead use the esPointInEventState object).
                       esPointValueStr 1.3.6.1.4.1.3052.18.1.1.1.1.7 displaystring read-only
A string referring to the value of a point on an EventSensor. For contact closures this object is either 'Open' or 'Closed'. For outputs this object is a concatenation of the logical state and physical state, separated by '/'. For a relay output this object can be one of the following 4 possible values: Active/Energized Inactive/Energized Active/De-energized Inactve/De-energized For a power output this object can be one of the following 2 possible values: On/Energized Off/De-energized For temperature and humidity point classes, this object is the string representation of the esPointValueInt object. For temperature, 'C' or 'F' is including in the string to indicate scale. For analog inputs, this object is the string representation of the plus/minus input in the configured units appended with the unit name.
                       esPointTimeLastChange 1.3.6.1.4.1.3052.18.1.1.1.1.8 displaystring read-only
The time of the last time an event was triggerred for a point on an EventSensor in MM/DD/YY HH:MM:SS format. For contact closures, the possible events are Active and Inactive. For temperature, humidity, and analog inputs, the possible events are Normal, High, Very High, Low, and Very Low. For outputs, this object is a null string.
                       esPointTimetickLastChange 1.3.6.1.4.1.3052.18.1.1.1.1.9 timeticks read-only
The time of the last time an event was triggerred for a point on an EventSensor in 100ths of seconds since reset. For contact closures, the possible events are Active and Inactive. For temperature, humidity, and analog inputs, the possible events are Normal, High, Very High, Low, and Very Low. For outputs, this object is a null string.
                       esPointAliasValueStr 1.3.6.1.4.1.3052.18.1.1.1.1.10 displaystring read-only
For CC inputs, this is the CC active/inactive alias setting setting value that currently corresponds to the event state. So if the CC input is in the event state, then this object is the active alias setting value. If the CC input is in the normal state, then this object is the inactive alias setting value. For relay/power outputs, this is the output active/inactive alias setting value that currently corresponds to the output state. So if the output is in the active state, then this object is the active alias setting value. If the output is in hte inactive state, then this object is the inactive alias setting value. For non-CC and non-output sensors, this is the same as the esPointValueStr object.
           dataEventStatus 1.3.6.1.4.1.3052.18.1.2
               deStatusTable 1.3.6.1.4.1.3052.18.1.2.1 no-access
Data Event Status Table
                   deStatusEntry 1.3.6.1.4.1.3052.18.1.2.1.1 no-access
EventSensor status entry
                       deStatusIndex 1.3.6.1.4.1.3052.18.1.2.1.1.1 integer32 read-only
Index for Data Events
                       deStatusName 1.3.6.1.4.1.3052.18.1.2.1.1.2 displaystring read-only
Data Event name
                       deStatusCounter 1.3.6.1.4.1.3052.18.1.2.1.1.3 integer32 read-only
Number of times a data record has matched this event's equation. Range: 1-999999999
                       deStatusThreshold 1.3.6.1.4.1.3052.18.1.2.1.1.4 integer32 read-only
Number of times the equation is matched before an event is triggered. Range: 1-999999999
           powerDistributionStatus 1.3.6.1.4.1.3052.18.1.5
               pdConfig 1.3.6.1.4.1.3052.18.1.5.1 displaystring read-only
Power Distribution output configuration
               pdNextGen 1.3.6.1.4.1.3052.18.1.5.4
                   pdnTable 1.3.6.1.4.1.3052.18.1.5.4.1 no-access
Table of power distribution objects arranged according to next-generation methodology (i.e., using multiple PowerBoss power distributors in addition to the on-board power distributor).
                       pdnEntry 1.3.6.1.4.1.3052.18.1.5.4.1.1 no-access
Entry for table of power distribution objects arranged according to next-generation methodology (i.e., using multiple PowerBoss power distributors in addition to the on-board power distributor).
                           pdnIndexPD 1.3.6.1.4.1.3052.18.1.5.4.1.1.1 integer32 read-only
Index for table of power distribution objects, specifically the index that refers to which power distributor. A value of 200 means the internal power distributor. A value from 1 to 16 refers to an external power distributor (PowerBoss), and is the same value as esIndexES, which refers to the PowerBoss as an EventSensor in the eventSensorStatus object table. In other words, pdnIndexPD is the same as esIndexES: esIndexES is used to refer to the PowerBoss as an eventsensor (i.e., control outputs), while pdnIndexPD is used to refer to the PowerBoss when used for power distribution monitoring (i.e., to alarm on output current/voltage/fuse status).
                           pdnIndexOutput 1.3.6.1.4.1.3052.18.1.5.4.1.1.2 integer32 read-only
Index for table of power distribution objects, specifically the index that refers to which output on the power distributor specified by pdnIndexPD. For objects where the output is irrelevant, this index should be 1.
                           pdnConfig 1.3.6.1.4.1.3052.18.1.5.4.1.1.3 displaystring read-only
The number of outputs on the power distributor specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainCurrentInEventState 1.3.6.1.4.1.3052.18.1.5.4.1.1.4 displaystring read-only
The event state of the current (i.e. Amps) event of the power distributor specified by pdnIndexPD. pdnIndexOutput should be 1 for this object. Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High', 'Very High'.
                           pdnMainCurrentValue 1.3.6.1.4.1.3052.18.1.5.4.1.1.5 integer32 read-only
The current drawn, in mA, for the power distributor specified by pdnIndexPD. If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) and refers to the current drawn by that PowerBoss and all equipment powered by that PowerBoss. pdnIndexOutput should be 1 for this object.
                           pdnMainCurrentValueStr 1.3.6.1.4.1.3052.18.1.5.4.1.1.6 displaystring read-only
Essentially pdnMainCurrentValue formatted as a string in units of Amps, with 3 decimal places. pdnIndexOutput should be 1 for this object.
                           pdnMainCurrentDeadband 1.3.6.1.4.1.3052.18.1.5.4.1.1.7 integer32 read-only
The deadband, in mA, for the main current sensor for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainCurrentVHighCurrent 1.3.6.1.4.1.3052.18.1.5.4.1.1.8 integer32 read-only
The current, in mA, for the main current sensor's Very High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainCurrentHighCurrent 1.3.6.1.4.1.3052.18.1.5.4.1.1.9 integer32 read-only
The current, in mA, for the main current sensor's High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainCurrentLowCurrent 1.3.6.1.4.1.3052.18.1.5.4.1.1.10 integer32 read-only
The current, in mA, for the main current sensor's Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainCurrentVLowCurrent 1.3.6.1.4.1.3052.18.1.5.4.1.1.11 integer32 read-only
The current, in mA, for the main current sensor's Very Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainVoltageInEventState 1.3.6.1.4.1.3052.18.1.5.4.1.1.12 displaystring read-only
The event state of the voltage event of the power distributor specified by pdnIndexPD. pdnIndexOutput should be 1 for this object. Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High', 'Very High'.
                           pdnMainVoltageValue 1.3.6.1.4.1.3052.18.1.5.4.1.1.13 integer32 read-only
The voltage, in mV, at the power distributor specified by pdnIndexPD. If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) and refers to the voltage at that PowerBoss and all equipment powered by that PowerBoss. pdnIndexOutput should be 1 for this object.
                           pdnMainVoltageValueStr 1.3.6.1.4.1.3052.18.1.5.4.1.1.14 displaystring read-only
Essentially pdnMainVoltageValue formatted as a string in units of Volts, with 3 decimal places. pdnIndexOutput should be 1 for this object.
                           pdnMainVoltageDeadband 1.3.6.1.4.1.3052.18.1.5.4.1.1.15 integer32 read-only
The deadband, in mV, for the main voltage sensor for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainVoltageVHighVoltage 1.3.6.1.4.1.3052.18.1.5.4.1.1.16 integer32 read-only
The voltage, in mA, for the main voltage sensor's Very High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainVoltageHighVoltage 1.3.6.1.4.1.3052.18.1.5.4.1.1.17 integer32 read-only
The voltage, in mV, for the main voltage sensor's High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainVoltageLowVoltage 1.3.6.1.4.1.3052.18.1.5.4.1.1.18 integer32 read-only
The voltage, in mV, for the main voltage sensor's Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainVoltageVLowVoltage 1.3.6.1.4.1.3052.18.1.5.4.1.1.19 integer32 read-only
The voltage, in mV, for the main voltage sensor's Very Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainPowerValue 1.3.6.1.4.1.3052.18.1.5.4.1.1.20 integer32 read-only
The power, in Watts, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.
                           pdnMainPowerValueStr 1.3.6.1.4.1.3052.18.1.5.4.1.1.21 displaystring read-only
The power, in Watts, for the power distributor specified by pdIndexPD, formatted as a string with the unit name 'Watts'. pdnIndexOutput should be 1 for this object.
                           pdnOutputCurrentInEventState 1.3.6.1.4.1.3052.18.1.5.4.1.1.22 displaystring read-only
The event state of the current (i.e. Amps) event of the power distributor output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=200 and pdnIndexOutput=2, this refers to power output #2 of the internal power distributor. Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High', 'Very High'.
                           pdnOutputCurrentValue 1.3.6.1.4.1.3052.18.1.5.4.1.1.23 integer32 read-only
The current drawn, in mA, for the power distributor output specified by pdnIndexPD and pdIndexOutput. E.g., if pdIndexPD is 3 then this is an external power distributor (PowerBoss) identified as 'power distributor 3' and refers to the current drawn by a specific power output on that PowerBoss. The specific power output is specified by pdIndexOutput.
                           pdnOutputCurrentValueStr 1.3.6.1.4.1.3052.18.1.5.4.1.1.24 displaystring read-only
Essentially pdnOutputCurrentValue formatted as a string in units of Amps, with 3 decimal places.
                           pdnOutputCurrentDeadband 1.3.6.1.4.1.3052.18.1.5.4.1.1.25 integer32 read-only
The deadband, in mA, for the main current sensor for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput.
                           pdnOutputCurrentVHighCurrent 1.3.6.1.4.1.3052.18.1.5.4.1.1.26 integer32 read-only
The current, in mA, for a specific power output's current sensor Very High event threshold, for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput.
                           pdnOutputCurrentHighCurrent 1.3.6.1.4.1.3052.18.1.5.4.1.1.27 integer32 read-only
The current, in mA, for a specific power output's current sensor High event threshold, for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput for this object.
                           pdnOutputCurrentLowCurrent 1.3.6.1.4.1.3052.18.1.5.4.1.1.28 integer32 read-only
The current, in mA, for a specific power output's current sensor Low event threshold, for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput for this object.
                           pdnOutputCurrentVLowCurrent 1.3.6.1.4.1.3052.18.1.5.4.1.1.29 integer32 read-only
The current, in mA, for a specific power output's current sensor Very Low event threshold, for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput for this object.
                           pdnOutputFuseInEventState 1.3.6.1.4.1.3052.18.1.5.4.1.1.30 displaystring read-only
The event state of the fuse event of the power distributor output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=14 and pdnIndexOutput=2, this refers to power output #2 of the external power distributor (PowerBoss), identified as 'power distributor 14'. Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High', 'Very High'. This object exists only for power distributors with fuse monitoring support.
                           pdnOutputFuseValueStr 1.3.6.1.4.1.3052.18.1.5.4.1.1.31 displaystring read-only
The state of the fuse of the power distributor output specified by pdnIndexPD and pdnIndexOutput. Possible values for this object are: 'BLOWN' and 'OK'. This object exists only for power distributors with fuse monitoring support.
                           pdnMainCombinedStatus 1.3.6.1.4.1.3052.18.1.5.4.1.1.32 displaystring read-only
Combined status string intended to be parsed by NMS: format: voltageColorCode`voltageEventState`voltageValue`mainCurrentColorCode`mainCurrentEventState`mainCurrentValue`deviceCurrentValue`mainPowerValue
                           pdnOutputCombinedStatusBlock1 1.3.6.1.4.1.3052.18.1.5.4.1.1.33 displaystring read-only
Combined status string intended to be parsed by NMS: format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~...
                           pdnOutputCombinedStatusBlock2 1.3.6.1.4.1.3052.18.1.5.4.1.1.34 displaystring read-only
Combined status string intended to be parsed by NMS: format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~...
                           pdnDeviceCurrentValue 1.3.6.1.4.1.3052.18.1.5.4.1.1.35 integer32 read-only
Current drawn by device in mA. For the internal power distributor device, this is the current drawn by the SiteBoss 571. For an external power distributor device (PowerBoss), this is the current drawn by the PowerBoss. This object exists only for power distributors with device current monitoring support.
                           pdnDeviceCurrentValueStr 1.3.6.1.4.1.3052.18.1.5.4.1.1.36 displaystring read-only
Current drawn by device as a string with units (Amps). For the internal power distributor device, this is the current drawn by the SiteBoss 571. For an external power distributor device (PowerBoss), this is the current drawn by the PowerBoss. This object exists only for power distributors with device current monitoring support.
               pdSystem 1.3.6.1.4.1.3052.18.1.5.5
                   pdSystemCurrent 1.3.6.1.4.1.3052.18.1.5.5.1 displaystring read-only
Total current drawn by all power distributors in system; that is, the sum of all pdnMainCurrentValue objects for all connected power distributors: internal and external.
                   pdSystemPower 1.3.6.1.4.1.3052.18.1.5.5.2 displaystring read-only
Total power used by all power distributors in system; that is, the sum of all pdnMainPowerValue objects for all connected power distributors: internal and external.
           fuelSensorStatus 1.3.6.1.4.1.3052.18.1.6
               fsStatusTable 1.3.6.1.4.1.3052.18.1.6.1 no-access
Fuel sensor status table
                   fsStatusEntry 1.3.6.1.4.1.3052.18.1.6.1.1 no-access
Fuel sensor status table entry
                       fsStatusIndex 1.3.6.1.4.1.3052.18.1.6.1.1.1 integer32 read-only
Index for fuel sensors
                       fsStatusName 1.3.6.1.4.1.3052.18.1.6.1.1.2 displaystring read-only
Fuel sensor name
                       fsStatusDeviceState 1.3.6.1.4.1.3052.18.1.6.1.1.3 displaystring read-only
Fuel sensor device state
                       fsStatusVolumeValueString 1.3.6.1.4.1.3052.18.1.6.1.1.4 displaystring read-only
Fuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads -999 when the fuel sensor is disconnected
                       fsStatusVolumePercentLevel 1.3.6.1.4.1.3052.18.1.6.1.1.7 displaystring read-only
Height of the fluid in the tank expressed as a percentage of the tank height, in hundredths of a percent.
                       fsStatusVolumeInEventState 1.3.6.1.4.1.3052.18.1.6.1.1.8 displaystring read-only
Current event status of the fuel sensor.
                       fsStatusCombined 1.3.6.1.4.1.3052.18.1.6.1.1.9 displaystring read-only
Combined status string intended to be parsed by NMS: deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`capacity`units`name
           wirelessModemStatus 1.3.6.1.4.1.3052.18.1.7
               wmsStatus 1.3.6.1.4.1.3052.18.1.7.1 displaystring read-only
Wireless modem status
               wmsSignal 1.3.6.1.4.1.3052.18.1.7.2 displaystring read-only
Wireless modem Signal strength
               wmsRSSI 1.3.6.1.4.1.3052.18.1.7.3 displaystring read-only
Wireless modem Signal strength (RSSI)
               wmsBER 1.3.6.1.4.1.3052.18.1.7.4 displaystring read-only
Wireless modem Bit Error Rate
               wmsUpdated 1.3.6.1.4.1.3052.18.1.7.5 displaystring read-only
Wireless modem info last update time
               wmsRegistration 1.3.6.1.4.1.3052.18.1.7.6 displaystring read-only
Wireless modem registration status
               wmsLAC 1.3.6.1.4.1.3052.18.1.7.7 displaystring read-only
Wireless modem Location Area Code
               wmsCellID 1.3.6.1.4.1.3052.18.1.7.8 displaystring read-only
Wireless modem Cell ID
               wmsIMSI 1.3.6.1.4.1.3052.18.1.7.9 displaystring read-only
Wireless modem Internation Mobile Subscriber Identity number
               wmsPhnum 1.3.6.1.4.1.3052.18.1.7.10 displaystring read-only
Wireless modem phone number
               wmsLocalIP 1.3.6.1.4.1.3052.18.1.7.11 displaystring read-only
Local IP address of modem on wireless network
               wmsMgfID 1.3.6.1.4.1.3052.18.1.7.12 displaystring read-only
Wireless modem manufacturer ID
               wmsModelID 1.3.6.1.4.1.3052.18.1.7.13 displaystring read-only
Wireless modem model ID
               wmsIMEI 1.3.6.1.4.1.3052.18.1.7.14 displaystring read-only
Wireless modem International Mobile Equipment Identity number
               wmsRevID 1.3.6.1.4.1.3052.18.1.7.15 displaystring read-only
Wireless modem revision ID
               wmsNetName 1.3.6.1.4.1.3052.18.1.7.16 displaystring read-only
Wireless modem network name
               wmsGPRSStatus 1.3.6.1.4.1.3052.18.1.7.17 displaystring read-only
Wireless modem (E)GPRS status
               wmsBand 1.3.6.1.4.1.3052.18.1.7.18 displaystring read-only
Wireless modem band
               wmsChannel 1.3.6.1.4.1.3052.18.1.7.19 displaystring read-only
Wireless modem channel
               wmsCountryCode 1.3.6.1.4.1.3052.18.1.7.20 displaystring read-only
Wireless modem country code
               wmsNetCode 1.3.6.1.4.1.3052.18.1.7.21 displaystring read-only
Wireless modem network code
               wmsPLMNColor 1.3.6.1.4.1.3052.18.1.7.22 displaystring read-only
Wireless modem PLMN color
               wmsBScolor 1.3.6.1.4.1.3052.18.1.7.23 displaystring read-only
Wireless modem BS color
               wmsMpRACH 1.3.6.1.4.1.3052.18.1.7.24 displaystring read-only
Wireless modem max power RACH
               wmsMinRxLevel 1.3.6.1.4.1.3052.18.1.7.25 displaystring read-only
Wireless modem minimum receive level
               wmsBaseCoeff 1.3.6.1.4.1.3052.18.1.7.26 displaystring read-only
Wireless modem base coefficient
               wmsSIMStatus 1.3.6.1.4.1.3052.18.1.7.27 displaystring read-only
WWireless modem SIM status
               wmsICCID 1.3.6.1.4.1.3052.18.1.7.28 displaystring read-only
Wireless modem SIM ICCID
               wmsModemType 1.3.6.1.4.1.3052.18.1.7.29 displaystring read-only
Wireless modem type
           acPowerMonitorStatus 1.3.6.1.4.1.3052.18.1.8
               acpmStatusTable 1.3.6.1.4.1.3052.18.1.8.1 no-access
AC power monitor status table
                   acpmStatusEntry 1.3.6.1.4.1.3052.18.1.8.1.1 no-access
AC power monitor status table entry
                       acpmsIndex 1.3.6.1.4.1.3052.18.1.8.1.1.1 integer32 read-only
Index for AC power monitors
                       acpmsName 1.3.6.1.4.1.3052.18.1.8.1.1.2 displaystring read-only
Name for the AC power monitor device.
                       acpmsAvgVoltageValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.3 displaystring read-only
Average voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1). This could be either the average of the phase voltages, or the sum of the phase voltages, depending on device configuration.
                       acpmsAvgVoltageMinStr 1.3.6.1.4.1.3052.18.1.8.1.1.4 displaystring read-only
Minimum average voltage value since last reset, in volts.
                       acpmsAvgVoltageMaxStr 1.3.6.1.4.1.3052.18.1.8.1.1.5 displaystring read-only
Maximum average voltage value since last reset, in volts.
                       acpmsAvgVoltageAvgStr 1.3.6.1.4.1.3052.18.1.8.1.1.6 displaystring read-only
Average average voltage value since last reset, in volts. This is the unit's average of its measurements of the average voltage reported by the AC power monitor device.
                       acpmsAvgVoltageInEventState 1.3.6.1.4.1.3052.18.1.8.1.1.7 displaystring read-only
Event state of this AC power monitor voltage (Low, Normal, High, etc.).
                       acpmsVoltagePhaseAValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.8 displaystring read-only
Phase A voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).
                       acpmsVoltagePhaseBValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.9 displaystring read-only
Phase B voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).
                       acpmsVoltagePhaseCValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.10 displaystring read-only
Phase C voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).
                       acpmsAvgCurrentValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.11 displaystring read-only
Average current, in amps. This is calculated using the formula (register * CT ratio * 0.001). This could be either the average of the phase currents, or the sum of the phase currents, depending on device configuration.
                       acpmsAvgCurrentMinStr 1.3.6.1.4.1.3052.18.1.8.1.1.12 displaystring read-only
Minimum average current value since last reset, in amps.
                       acpmsAvgCurrentMaxStr 1.3.6.1.4.1.3052.18.1.8.1.1.13 displaystring read-only
Maximum average current value since last reset, in amps.
                       acpmsAvgCurrentAvgStr 1.3.6.1.4.1.3052.18.1.8.1.1.14 displaystring read-only
Average average current value since last reset, in amps. This is the unit's average of its measurements of the average current reported by the AC power monitor device.
                       acpmsAvgCurrentInEventState 1.3.6.1.4.1.3052.18.1.8.1.1.15 displaystring read-only
Event state of this AC power monitor current (Low, Normal, High, etc.).
                       acpmsCurrentPhaseAValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.16 displaystring read-only
Phase A current, in amps. This is calculated using the formula (register * CT ratio * 0.001).
                       acpmsCurrentPhaseBValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.17 displaystring read-only
Phase B current, in amps. This is calculated using the formula (register * CT ratio * 0.001).
                       acpmsCurrentPhaseCValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.18 displaystring read-only
Phase C current, in amps. This is calculated using the formula (register * CT ratio * 0.001).
                       acpmsAvgFreqValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.19 displaystring read-only
Frequency, in hertz. On the YD2010, this is calculated using the formula (register * 0.00106813). On the WattsOn, this is calculated using the formula (register * 0.1).
                       acpmsAvgFreqMinStr 1.3.6.1.4.1.3052.18.1.8.1.1.20 displaystring read-only
Minimum frequency value since last reset, in hertz.
                       acpmsAvgFreqMaxStr 1.3.6.1.4.1.3052.18.1.8.1.1.21 displaystring read-only
Maximum frequency value since last reset, in hertz.
                       acpmsAvgFreqAvgStr 1.3.6.1.4.1.3052.18.1.8.1.1.22 displaystring read-only
Average frequency value since last reset, in hertz. This is the unit's average of its measurements of the average frequency reported by the AC power monitor device.
                       acpmsAvgFreqInEventState 1.3.6.1.4.1.3052.18.1.8.1.1.23 displaystring read-only
Event state of this AC power monitor frequency (Low, Normal, High, etc.).
                       acpmsTRPValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.24 displaystring read-only
Total real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn models, this is calculated using the formula (register * PT * CT).
                       acpmsTRPMinStr 1.3.6.1.4.1.3052.18.1.8.1.1.25 displaystring read-only
Minimum total real power value since last reset, in watts.
                       acpmsTRPMaxStr 1.3.6.1.4.1.3052.18.1.8.1.1.26 displaystring read-only
Maximum total real power value since last reset, in watts.
                       acpmsTRPAvgStr 1.3.6.1.4.1.3052.18.1.8.1.1.27 displaystring read-only
Average total real power value since last reset, in watts. This is the unit's average of its measurements of the average total real power reported by the AC power monitor device.
                       acpmsTRPInEventState 1.3.6.1.4.1.3052.18.1.8.1.1.28 displaystring read-only
Event state of this AC power monitor total real power (Low, Normal, High, etc.).
                       acpmsRPPhaseAValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.29 displaystring read-only
Phase A real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT).
                       acpmsRPPhaseBValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.30 displaystring read-only
Phase B real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT).
                       acpmsRPPhaseCValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.31 displaystring read-only
Phase C real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT).
                       acpmsCombined 1.3.6.1.4.1.3052.18.1.8.1.1.32 displaystring read-only
Combined status string intended to be parsed by NMS: name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`currentEventState`currentColorCode`frequencyEventState`frequencyColorCode`powerEventState`powerColorCode
                       acpmsTPFValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.33 displaystring read-only
Total power factor.
                       acpmsTPFMinStr 1.3.6.1.4.1.3052.18.1.8.1.1.34 displaystring read-only
Total power factor minimum value since last reset.
                       acpmsTPFMaxStr 1.3.6.1.4.1.3052.18.1.8.1.1.35 displaystring read-only
Total power factor maximum value since last reset.
                       acpmsTPFAvgStr 1.3.6.1.4.1.3052.18.1.8.1.1.36 displaystring read-only
Total power factor average value since last reset.
                       acpmsTPFInEventState 1.3.6.1.4.1.3052.18.1.8.1.1.37 displaystring read-only
Total power factor event state.
                       acpmsPFPhaseAValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.38 displaystring read-only
Phase A power factor.
                       acpmsPFPhaseBValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.39 displaystring read-only
Phase B power factor.
                       acpmsPFPhaseCValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.40 displaystring read-only
Phase C power factor.
                       acpmsTRcPValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.41 displaystring read-only
Total reactive power, in VAR.
                       acpmsTRcPMinStr 1.3.6.1.4.1.3052.18.1.8.1.1.42 displaystring read-only
Total reactive power minimum value since last reset, in VAR.
                       acpmsTRcPMaxStr 1.3.6.1.4.1.3052.18.1.8.1.1.43 displaystring read-only
Total reactive power maximum value since last reset, in VAR.
                       acpmsTRcPAvgStr 1.3.6.1.4.1.3052.18.1.8.1.1.44 displaystring read-only
Total reactive power average value since last reset, in VAR.
                       acpmsRcPPhaseAValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.45 displaystring read-only
Phase A reactive power, in VAR.
                       acpmsRcPPhaseBValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.46 displaystring read-only
Phase B reactive power, in VAR.
                       acpmsRcPPhaseCValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.47 displaystring read-only
Phase C reactive power, in VAR.
                       acpmsTAPValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.48 displaystring read-only
Total apparent power, in VA.
                       acpmsTAPMinStr 1.3.6.1.4.1.3052.18.1.8.1.1.49 displaystring read-only
Total apparent power minimum value since last reset, in VA.
                       acpmsTAPMaxStr 1.3.6.1.4.1.3052.18.1.8.1.1.50 displaystring read-only
Total apparent power maximum value since last reset, in VA.
                       acpmsTAPAvgStr 1.3.6.1.4.1.3052.18.1.8.1.1.51 displaystring read-only
Total apparent power average value since last reset, in VA.
                       acpmsAPPhaseAValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.52 displaystring read-only
Phase A apparent power, in VA.
                       acpmsAPPhaseBValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.53 displaystring read-only
Phase B apparent power, in VA.
                       acpmsAPPhaseCValueStr 1.3.6.1.4.1.3052.18.1.8.1.1.54 displaystring read-only
Phase C apparent power, in VA.
                       acpmsTotalEnergyWh 1.3.6.1.4.1.3052.18.1.8.1.1.55 integer32 read-only
Total energy, in Wh.
                       acpmsTotalEnergyVAR 1.3.6.1.4.1.3052.18.1.8.1.1.56 integer32 read-only
Total reactive energy, in VAR.
                       acpmsTotalEnergyVA 1.3.6.1.4.1.3052.18.1.8.1.1.57 integer32 read-only
Total apparent energy, in VA.
           batteryMonitorStatus 1.3.6.1.4.1.3052.18.1.10
                 bmStatusTable 1.3.6.1.4.1.3052.18.1.10.1 no-access
Battery monitor status table.
                     bmStatusEntry 1.3.6.1.4.1.3052.18.1.10.1.1 no-access
Battery monitor status table entry.
                         bmsIndex 1.3.6.1.4.1.3052.18.1.10.1.1.1 integer32 read-only
Index for battery monitors.
                         bmsEnable 1.3.6.1.4.1.3052.18.1.10.1.1.2 displaystring read-only
ON/OFF enable for this battery monitor.
                         bmsName 1.3.6.1.4.1.3052.18.1.10.1.1.3 displaystring read-only
Name for this battery monitor.
                         bmsState 1.3.6.1.4.1.3052.18.1.10.1.1.4 displaystring read-only
The connected state of the battery monitor. If you unplug the carrier then all three of its battery monitor states will reflect the same state change.
                         bmsStringState 1.3.6.1.4.1.3052.18.1.10.1.1.5 displaystring read-only
State of the string monitored by its battery monitor.
                         bmsTempValue 1.3.6.1.4.1.3052.18.1.10.1.1.6 displaystring read-only
Average jar temperature value in C or F, depending on scale setting. Displayed as a floating point value. -999.0 means this is unknown.
                         bmsTempValueStr 1.3.6.1.4.1.3052.18.1.10.1.1.7 displaystring read-only
Average jar temperature with appropriate scale appended. Displayed as a floating point value. -999.0 means this is unknown.
                         bmsTempEvent 1.3.6.1.4.1.3052.18.1.10.1.1.8 displaystring read-only
Event state of this battery monitor average jar temperature (Low, Normal, High).
                         bmsDiffTempValue 1.3.6.1.4.1.3052.18.1.10.1.1.9 integer32 read-only
Differential temperature in C or F, depending on scale setting. -999 means this is unknown.
                         bmsDiffTempValueStr 1.3.6.1.4.1.3052.18.1.10.1.1.10 displaystring read-only
Differential temperature with appropriate scale (C or F) appended. -999 means this is unknown.
                         bmsDiffTempEvent 1.3.6.1.4.1.3052.18.1.10.1.1.11 displaystring read-only
Event state of this battery monitor differential temperature (Very High, High, Normal).
                         bmsVoltageValue 1.3.6.1.4.1.3052.18.1.10.1.1.12 displaystring read-only
Total battery voltage on the string, in volts. Displayed as a floating point value in format X.X. -999.0 means this is unknown.
                         bmsVoltageEvent 1.3.6.1.4.1.3052.18.1.10.1.1.13 displaystring read-only
Event state of this battery monitor string voltage (Low, Normal, High, etc.).
                         bmsDiffVoltValue 1.3.6.1.4.1.3052.18.1.10.1.1.14 displaystring read-only
Differential voltage in volts. Displayed as a floating point value in format X.X. -999.0 means this is unknown.
                         bmsDiffVoltEvent 1.3.6.1.4.1.3052.18.1.10.1.1.15 displaystring read-only
Event state of this battery monitor differential voltage (Very High, High, Normal.)
                         bmsCurrentValue 1.3.6.1.4.1.3052.18.1.10.1.1.16 displaystring read-only
Current flow on the string, in amperes. Displayed as a floating point value in format X.X. A positive value means the battery string is charging, and a negative value means the battery string is discharging. -999.0 means this is unknown.
                         bmsChargingCurrentEvent 1.3.6.1.4.1.3052.18.1.10.1.1.17 displaystring read-only
Event state of this battery monitor charging current (Low, Normal, High, etc.).
                         bmsDischargingCurrentEvent 1.3.6.1.4.1.3052.18.1.10.1.1.18 displaystring read-only
Event state of this battery monitor discharging current (Low, Normal, High, etc.).
                         bmsChargeLevelValue 1.3.6.1.4.1.3052.18.1.10.1.1.19 displaystring read-only
Charge level of the battery string.
                         bmsChargeLevelEvent 1.3.6.1.4.1.3052.18.1.10.1.1.20 displaystring read-only
Event state of this battery monitor charge level (Very Low, Low, Normal).
                         bmsJarHealthValue 1.3.6.1.4.1.3052.18.1.10.1.1.21 displaystring read-only
Jar health of the battery string.
                         bmsJarHealthEvent 1.3.6.1.4.1.3052.18.1.10.1.1.22 displaystring read-only
Event state of this battery monitor jar health (Very Low, Low, Normal).
                         bmsCombined 1.3.6.1.4.1.3052.18.1.10.1.1.23 displaystring read-only
Combined status string intended to be parsed by NMS: name`deviceState`deviceStateColorCode`stringState`charge`voltage`temp`health~chargeEventState`chargeColorCode`voltageEventState`voltageColorCode`tempEventState`tempColorCode`healthEventState`healthColorCode`numActiveEvents
                 bmsJarStatusTable 1.3.6.1.4.1.3052.18.1.10.2 no-access
This table organizes per-jar attributes of a battery monitor: 1. voltage 2. temperature.
                     bmJarStatusEntry 1.3.6.1.4.1.3052.18.1.10.2.1 no-access
Entry for battery monitor jar status table. Note this table uses 2 SNMP indexes: the first for which battery monitor and the second for which jar.
                         bmjsIndexBM 1.3.6.1.4.1.3052.18.1.10.2.1.1 integer32 read-only
The part of the index that refers to which battery monitor.
                         bmjsIndexJar 1.3.6.1.4.1.3052.18.1.10.2.1.2 integer32 read-only
The part of the index that refers to which jar.
                         bmjsVoltageValue 1.3.6.1.4.1.3052.18.1.10.2.1.3 displaystring read-only
Voltage of individual battery cell. This is a floating point value in format X.X. -999.0 means this is unknown.
                         bmjsTempValue 1.3.6.1.4.1.3052.18.1.10.2.1.4 displaystring read-only
Temperature of individual battery jar. This is a floating point value. -999.0 means unknown.
                         bmjsAdmittanceValue 1.3.6.1.4.1.3052.18.1.10.2.1.5 integer32 read-only
Cell admittance of individual jar. This is an integer value. -999 means unknown.
                         bmjsAdmittanceChangeValue 1.3.6.1.4.1.3052.18.1.10.2.1.6 integer32 read-only
Percent change of cell admittance of individual jar. This is an integer value.
       config 1.3.6.1.4.1.3052.18.2
           eventSensorBasics 1.3.6.1.4.1.3052.18.2.1
               esNumberEventSensors 1.3.6.1.4.1.3052.18.2.1.1 integer32 read-only
The number of EventSensors recognized by the unit, including the internal EventSensor. Range: 1-17
               esTable 1.3.6.1.4.1.3052.18.2.1.2 no-access
The table of what EventSensors are attached to the unit, including the internal EventSensor
                   esEntry 1.3.6.1.4.1.3052.18.2.1.2.1 no-access
Table entry for EventSensor table
                       esIndex 1.3.6.1.4.1.3052.18.2.1.2.1.1 integer32 read-only
This number refers to an EventSensor; it has the same meaning as the esIndexES object (see above), except that this object is used only within the esTable branch. This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndex=2 will now refer to that particular EventSensor.
                       esName 1.3.6.1.4.1.3052.18.2.1.2.1.2 displaystring read-only
The name of the EventSensor
                       esID 1.3.6.1.4.1.3052.18.2.1.2.1.3 displaystring read-only
The factory-assigned ID of the EventSensor
                       esNumberTempSensors 1.3.6.1.4.1.3052.18.2.1.2.1.4 integer32 read-only
The number of temperature sensors on the EventSensor
                       esTempReportingMode 1.3.6.1.4.1.3052.18.2.1.2.1.5 displaystring read-only
Description of how temperature values should be interpreted.
                       esNumberCCs 1.3.6.1.4.1.3052.18.2.1.2.1.6 integer32 read-only
The number of contact closures on the EventSensor.
                       esCCReportingMode 1.3.6.1.4.1.3052.18.2.1.2.1.7 displaystring read-only
Description of how CC values should be interpreted.
                       esNumberHumidSensors 1.3.6.1.4.1.3052.18.2.1.2.1.8 integer32 read-only
The number of humidity sensors on the EventSensor.
                       esHumidReportingMode 1.3.6.1.4.1.3052.18.2.1.2.1.9 displaystring read-only
Description of how humidity sensor values should be interpreted.
                       esNumberNoiseSensors 1.3.6.1.4.1.3052.18.2.1.2.1.10 integer32 read-only
The number of noise sensors on the EventSensor.
                       esNoiseReportingMode 1.3.6.1.4.1.3052.18.2.1.2.1.11 displaystring read-only
Description of how noise sensor values should be interpreted.
                       esNumberAirflowSensors 1.3.6.1.4.1.3052.18.2.1.2.1.12 integer32 read-only
The number of airflow sensors on the EventSensor.
                       esAirflowReportingMode 1.3.6.1.4.1.3052.18.2.1.2.1.13 displaystring read-only
Description of how airflow sensor values should be interpreted.
                       esNumberAnalog 1.3.6.1.4.1.3052.18.2.1.2.1.14 integer32 read-only
The number of analog inputs on the EventSensor.
                       esAnalogReportingMode 1.3.6.1.4.1.3052.18.2.1.2.1.15 displaystring read-only
Description of how analog input values should be interpreted.
                       esNumberOutputs 1.3.6.1.4.1.3052.18.2.1.2.1.16 integer32 read-only
The number of outputs (relay or power) on the EventSensor
                       esOutputReportingMode 1.3.6.1.4.1.3052.18.2.1.2.1.17 displaystring read-only
Description of how output values should be interpreted.
                       esTempCombinedStatus 1.3.6.1.4.1.3052.18.2.1.2.1.18 displaystring read-only
Combined status string intended to be parsed by NMS: name`value`scale`eventState`eventColorCode
                       esCCCombinedStatusBlock1 1.3.6.1.4.1.3052.18.2.1.2.1.19 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8
                       esCCCombinedStatusBlock2 1.3.6.1.4.1.3052.18.2.1.2.1.20 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alias16
                       esCCCombinedStatusBlock3 1.3.6.1.4.1.3052.18.2.1.2.1.21 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`alias24
                       esCCCombinedStatusBlock4 1.3.6.1.4.1.3052.18.2.1.2.1.22 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`alias32
                       esCCCombinedStatusBlock5 1.3.6.1.4.1.3052.18.2.1.2.1.23 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`alias40
                       esCCCombinedStatusBlock6 1.3.6.1.4.1.3052.18.2.1.2.1.24 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`alias48
                       esCCCombinedStatusBlock7 1.3.6.1.4.1.3052.18.2.1.2.1.25 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`alias56
                       esCCCombinedStatusBlock8 1.3.6.1.4.1.3052.18.2.1.2.1.26 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64`alias64
                       esHumidCombinedStatus 1.3.6.1.4.1.3052.18.2.1.2.1.27 displaystring read-only
Combined status string intended to be parsed by NMS: name`value`eventState`eventColorCode
                       esAnalogCombinedStatusBlock1 1.3.6.1.4.1.3052.18.2.1.2.1.28 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~...
                       esAnalogCombinedStatusBlock2 1.3.6.1.4.1.3052.18.2.1.2.1.29 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~name9`value9`units9`eventState9`eventColorCode9~...
                       esAnalogCombinedStatusBlock3 1.3.6.1.4.1.3052.18.2.1.2.1.30 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...
                       esAnalogCombinedStatusBlock4 1.3.6.1.4.1.3052.18.2.1.2.1.31 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...
                       esAnalogCombinedStatusBlock5 1.3.6.1.4.1.3052.18.2.1.2.1.32 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...
                       esAnalogCombinedStatusBlock6 1.3.6.1.4.1.3052.18.2.1.2.1.33 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...
                       esOutputCombinedStatusBlock1 1.3.6.1.4.1.3052.18.2.1.2.1.34 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...
                       esOutputCombinedStatusBlock2 1.3.6.1.4.1.3052.18.2.1.2.1.35 displaystring read-only
Combined status string intended to be parsed by NMS: numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliasz
               esNewSensors 1.3.6.1.4.1.3052.18.2.1.3 displaystring read-only
String representing the number of new (attached but unconfigured) EventSensors
           eventSensorPointConfig 1.3.6.1.4.1.3052.18.2.2
               esPointConfigTempTable 1.3.6.1.4.1.3052.18.2.2.1 no-access
This table organizes 3 basic attributes of temperature sensor points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number (always 1 for temp sensors) Points are referenced by a point config index. The point config index is a string of 2 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor within the context of this emperature point config table ; namely, which EventSensor, and which sensor (a.k.a. point) (always 1 for temperature sensors).
                   esPointConfigTempEntry 1.3.6.1.4.1.3052.18.2.2.1.1 no-access
Entry for EventSensor point config temperature table
                       espcTempIndexES 1.3.6.1.4.1.3052.18.2.2.1.1.1 integer32 read-only
The part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config temperature table; namely, which EventSensor, and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor.
                       espcTempIndexPoint 1.3.6.1.4.1.3052.18.2.2.1.1.2 integer32 read-only
The part of the point index that delineates which sensor on the EventSensor. So this combined with espcTempIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of temperature point configuration.
                       espcTempEnable 1.3.6.1.4.1.3052.18.2.2.1.1.3 displaystring read-write
ON/OFF enable this temperature sensor
                       espcTempScale 1.3.6.1.4.1.3052.18.2.2.1.1.4 displaystring read-write
Scale (C/F) for this temperature sensor
                       espcTempDeadband 1.3.6.1.4.1.3052.18.2.2.1.1.5 displaystring read-write
Deadband for this temperature sensor (in floating-point format)
                       espcTempVHighTemp 1.3.6.1.4.1.3052.18.2.2.1.1.6 displaystring read-write
Very high temperature event threshold for this temperature sensor (in floating-point format)
                       espcTempVHighActions 1.3.6.1.4.1.3052.18.2.2.1.1.7 displaystring read-write
Very high temperature event actions for this temperature sensor
                       espcTempVHighTrapnum 1.3.6.1.4.1.3052.18.2.2.1.1.8 integer32 read-write
Very high temperature event trap number for this temperature sensor
                       espcTempVHighClass 1.3.6.1.4.1.3052.18.2.2.1.1.9 displaystring read-write
Very high temperature event class for this temperature sensor
                       espcTempHighTemp 1.3.6.1.4.1.3052.18.2.2.1.1.10 displaystring read-write
High temperature event threshold for this temperature sensor (in floating-point format)
                       espcTempHighActions 1.3.6.1.4.1.3052.18.2.2.1.1.11 displaystring read-write
High temperature event actions for this temperature sensor
                       espcTempHighTrapnum 1.3.6.1.4.1.3052.18.2.2.1.1.12 integer32 read-write
High temperature event trap number for this temperature sensor
                       espcTempHighClass 1.3.6.1.4.1.3052.18.2.2.1.1.13 displaystring read-write
High temperature event class for this temperature sensor
                       espcTempNormalActions 1.3.6.1.4.1.3052.18.2.2.1.1.14 displaystring read-write
Return-to-normal event actions for this temperature sensor
                       espcTempNormalTrapnum 1.3.6.1.4.1.3052.18.2.2.1.1.15 integer32 read-write
Return-to-normal event trap number for this temperature sensor
                       espcTempNormalClass 1.3.6.1.4.1.3052.18.2.2.1.1.16 displaystring read-write
Return-to-normal event class for this temperature sensor
                       espcTempLowTemp 1.3.6.1.4.1.3052.18.2.2.1.1.17 displaystring read-write
Low temperature event threshold for this temperature sensor (in floating-point format)
                       espcTempLowActions 1.3.6.1.4.1.3052.18.2.2.1.1.18 displaystring read-write
Low temperature event actions for this temperature sensor
                       espcTempLowTrapnum 1.3.6.1.4.1.3052.18.2.2.1.1.19 integer32 read-write
Low temperature event trap number for this temperature sensor
                       espcTempLowClass 1.3.6.1.4.1.3052.18.2.2.1.1.20 displaystring read-write
Low temperature event class for this temperature sensor
                       espcTempVLowTemp 1.3.6.1.4.1.3052.18.2.2.1.1.21 displaystring read-write
Very Low temperature event threshold for this temperature sensor (in floating-point format)
                       espcTempVLowActions 1.3.6.1.4.1.3052.18.2.2.1.1.22 displaystring read-write
Very Low temperature event actions for this temperature sensor
                       espcTempVLowTrapnum 1.3.6.1.4.1.3052.18.2.2.1.1.23 integer32 read-write
Very Low temperature event trap number for this temperature sensor
                       espcTempVLowClass 1.3.6.1.4.1.3052.18.2.2.1.1.24 displaystring read-write
Very Low temperature event class for this temperature sensor
               esPointConfigCCTable 1.3.6.1.4.1.3052.18.2.2.2 no-access
This table organizes 3 basic attributes of contact closure points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this contact closure point config table ; namely, which EventSensor and which sensor.
                   esPointConfigCCEntry 1.3.6.1.4.1.3052.18.2.2.2.1 no-access
Entry for EventSensor point config contact closure table
                       espcCCIndexES 1.3.6.1.4.1.3052.18.2.2.2.1.1 integer32 read-only
The part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.
                       espcCCIndexPoint 1.3.6.1.4.1.3052.18.2.2.2.1.2 integer32 read-only
The part of the point index that delineates which sensor on the EventSensor. So this combined with espcCCIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration.
                       espcCCEnable 1.3.6.1.4.1.3052.18.2.2.2.1.3 displaystring read-write
ON/OFF enable for this contact closure
                       espcCCName 1.3.6.1.4.1.3052.18.2.2.2.1.4 displaystring read-write
Name for this contact closure
                       espcCCEventState 1.3.6.1.4.1.3052.18.2.2.2.1.5 displaystring read-write
Event state for this contact closure
                       espcCCThreshold 1.3.6.1.4.1.3052.18.2.2.2.1.6 integer32 read-write
Event threshold (seconds) for this contact closure
                       espcCCEventActions 1.3.6.1.4.1.3052.18.2.2.2.1.7 displaystring read-write
Event actions for this contact closure
                       espcCCEventTrapnum 1.3.6.1.4.1.3052.18.2.2.2.1.8 integer32 read-write
Event trap number for this contact closure
                       espcCCEventClass 1.3.6.1.4.1.3052.18.2.2.2.1.9 displaystring read-write
Event class for this contact closure
                       espcCCNormalActions 1.3.6.1.4.1.3052.18.2.2.2.1.10 displaystring read-write
Return-to-normal actions for this contact closure
                       espcCCNormalTrapnum 1.3.6.1.4.1.3052.18.2.2.2.1.11 integer32 read-write
Return-to-normal trap number for this contact closure
                       espcCCNormalClass 1.3.6.1.4.1.3052.18.2.2.2.1.12 displaystring read-write
Return-to-normal class for this contact closure
                       espcCCAlarmAlias 1.3.6.1.4.1.3052.18.2.2.2.1.13 displaystring read-write
Event alias for this contact closure
                       espcCCNormalAlias 1.3.6.1.4.1.3052.18.2.2.2.1.14 displaystring read-write
Return-to-normal alias for this contact closure
                       espcCCNormalThreshold 1.3.6.1.4.1.3052.18.2.2.2.1.15 integer32 read-write
Event threshold (seconds) for this contact closure to return to normal
                       espcCCOverrideGlobalReminder 1.3.6.1.4.1.3052.18.2.2.2.1.16 displaystring read-write
Override global reminder interval (evReminderInterval) for this CC.
                       espcCCReminderInterval 1.3.6.1.4.1.3052.18.2.2.2.1.17 integer32 read-write
Individual reminder interval for this CC, applicable when the global reminder is overriden.
               esPointConfigHumidTable 1.3.6.1.4.1.3052.18.2.2.3 no-access
This table organizes 3 basic attributes of humidity points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number (always 1 for humidity sensors) Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this humidity point config table ; namely, which EventSensor and which sensor.
                   esPointConfigHumidEntry 1.3.6.1.4.1.3052.18.2.2.3.1 no-access
Entry for EventSensor point config humidity table
                       espcHumidIndexES 1.3.6.1.4.1.3052.18.2.2.3.1.1 integer32 read-only
The part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.
                       espcHumidIndexPoint 1.3.6.1.4.1.3052.18.2.2.3.1.2 integer32 read-only
The part of the point index that delineates which sensor on the EventSensor. So this combined with espcHumidIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration.
                       espcHumidEnable 1.3.6.1.4.1.3052.18.2.2.3.1.3 displaystring read-write
ON/OFF enable for this humidity sensor
                       espcHumidDeadband 1.3.6.1.4.1.3052.18.2.2.3.1.4 integer32 read-write
Deadband for this humidity sensor
                       espcHumidVHighHumid 1.3.6.1.4.1.3052.18.2.2.3.1.5 integer32 read-write
Very high event threshold for this humidity sensor
                       espcHumidVHighActions 1.3.6.1.4.1.3052.18.2.2.3.1.6 displaystring read-write
Very high event actions for this humidity sensor
                       espcHumidVHighTrapnum 1.3.6.1.4.1.3052.18.2.2.3.1.7 integer32 read-write
Very high event trap number for this humidity sensor
                       espcHumidVHighClass 1.3.6.1.4.1.3052.18.2.2.3.1.8 displaystring read-write
Very high event class for this humidity sensor
                       espcHumidHighHumid 1.3.6.1.4.1.3052.18.2.2.3.1.9 integer32 read-write
High event threshold for this humidity sensor
                       espcHumidHighActions 1.3.6.1.4.1.3052.18.2.2.3.1.10 displaystring read-write
High event actions for this humidity sensor
                       espcHumidHighTrapnum 1.3.6.1.4.1.3052.18.2.2.3.1.11 integer32 read-write
High event trap number for this humidity sensor
                       espcHumidHighClass 1.3.6.1.4.1.3052.18.2.2.3.1.12 displaystring read-write
High event class for this humidity sensor
                       espcHumidNormalActions 1.3.6.1.4.1.3052.18.2.2.3.1.13 displaystring read-write
Return-to-normal actions for this humidity sensor
                       espcHumidNormalTrapnum 1.3.6.1.4.1.3052.18.2.2.3.1.14 integer32 read-write
Return-to-normal trap number for this humidity sensor
                       espcHumidNormalClass 1.3.6.1.4.1.3052.18.2.2.3.1.15 displaystring read-write
Return-to-normal class for this humidity sensor
                       espcHumidLowHumid 1.3.6.1.4.1.3052.18.2.2.3.1.16 integer32 read-write
Low event threshold for this humidity sensor
                       espcHumidLowActions 1.3.6.1.4.1.3052.18.2.2.3.1.17 displaystring read-write
Low event actions for this humidity sensor
                       espcHumidLowTrapnum 1.3.6.1.4.1.3052.18.2.2.3.1.18 integer32 read-write
Low event trap number for this humidity sensor
                       espcHumidLowClass 1.3.6.1.4.1.3052.18.2.2.3.1.19 displaystring read-write
Low event class for this humidity sensor
                       espcHumidVLowHumid 1.3.6.1.4.1.3052.18.2.2.3.1.20 integer32 read-write
Very low event threshold for this humidity sensor
                       espcHumidVLowActions 1.3.6.1.4.1.3052.18.2.2.3.1.21 displaystring read-write
Very low event actions for this humidity sensor
                       espcHumidVLowTrapnum 1.3.6.1.4.1.3052.18.2.2.3.1.22 integer32 read-write
Very low event trap number for this humidity sensor
                       espcHumidVLowClass 1.3.6.1.4.1.3052.18.2.2.3.1.23 displaystring read-write
Very low event class for this humidity sensor
               esPointConfigAITable 1.3.6.1.4.1.3052.18.2.2.5 no-access
This table organizes 3 basic attributes of analog input points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this analog input point config table ; namely, which EventSensor and which sensor.
                   esPointConfigAIEntry 1.3.6.1.4.1.3052.18.2.2.5.1 no-access
Entry for EventSensor point config analog input table
                       espcAIIndexES 1.3.6.1.4.1.3052.18.2.2.5.1.1 integer32 read-only
The part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.
                       espcAIIndexPoint 1.3.6.1.4.1.3052.18.2.2.5.1.2 integer32 read-only
The part of the point index that delineates which sensor on the EventSensor. So this combined with espcAIIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration.
                       espcAIEnable 1.3.6.1.4.1.3052.18.2.2.5.1.3 displaystring read-write
ON/OFF for this analog input sensor
                       espcAIDeadband 1.3.6.1.4.1.3052.18.2.2.5.1.5 displaystring read-write
Deadband for this analog input sensor
                       espcAIVhighValue 1.3.6.1.4.1.3052.18.2.2.5.1.6 displaystring read-write
Very high event threshold (decivolts or tenths of milliamps) for this analog input sensor
                       espcAIVhighActions 1.3.6.1.4.1.3052.18.2.2.5.1.7 displaystring read-write
Very high event actions for this analog input sensor
                       espcAIVhighTrapnum 1.3.6.1.4.1.3052.18.2.2.5.1.8 integer32 read-write
Very high event trap number for this analog input sensor
                       espcAIVhighClass 1.3.6.1.4.1.3052.18.2.2.5.1.9 displaystring read-write
Very high event class for this analog input sensor
                       espcAIHighValue 1.3.6.1.4.1.3052.18.2.2.5.1.10 displaystring read-write
High event threshold (decivolts or tenths of milliamps) for this analog input sensor
                       espcAIHighActions 1.3.6.1.4.1.3052.18.2.2.5.1.11 displaystring read-write
High event actions for this analog input sensor
                       espcAIHighTrapnum 1.3.6.1.4.1.3052.18.2.2.5.1.12 integer32 read-write
High event trap number for this analog input sensor
                       espcAIHighClass 1.3.6.1.4.1.3052.18.2.2.5.1.13 displaystring read-write
High event class for this analog input sensor
                       espcAINormalActions 1.3.6.1.4.1.3052.18.2.2.5.1.14 displaystring read-write
Return-to-normal actions for this analog input sensor
                       espcAINormalTrapnum 1.3.6.1.4.1.3052.18.2.2.5.1.15 integer32 read-write
Return-to-normal trap number for this analog input sensor
                       espcAINormalClass 1.3.6.1.4.1.3052.18.2.2.5.1.16 displaystring read-write
Return-to-normal class for this analog input sensor
                       espcAILowValue 1.3.6.1.4.1.3052.18.2.2.5.1.17 displaystring read-write
Low event threshold (decivolts or tenths of milliamps) for this analog input sensor
                       espcAILowActions 1.3.6.1.4.1.3052.18.2.2.5.1.18 displaystring read-write
Low event actions for this analog input sensor
                       espcAILowTrapnum 1.3.6.1.4.1.3052.18.2.2.5.1.19 integer32 read-write
Low event trap number for this analog input sensor
                       espcAILowClass 1.3.6.1.4.1.3052.18.2.2.5.1.20 displaystring read-write
Low event class for this analog input sensor
                       espcAIVlowValue 1.3.6.1.4.1.3052.18.2.2.5.1.21 displaystring read-write
Very low event threshold (decivolts or tenths of milliamps) for this analog input sensor
                       espcAIVlowActions 1.3.6.1.4.1.3052.18.2.2.5.1.22 displaystring read-write
Very low event actions for this analog input sensor
                       espcAIVlowTrapnum 1.3.6.1.4.1.3052.18.2.2.5.1.23 integer32 read-write
Very low event actions for this analog input sensor
                       espcAIVlowClass 1.3.6.1.4.1.3052.18.2.2.5.1.24 displaystring read-write
Very low event class for this analog input sensor
                       espcAIConvUnitName 1.3.6.1.4.1.3052.18.2.2.5.1.25 displaystring read-write
Converstion unit name for this analog input sensor
                       espcAIConvHighValue 1.3.6.1.4.1.3052.18.2.2.5.1.26 displaystring read-write
Conversion high value for this analog input sensor
                       espcAIConvHighUnit 1.3.6.1.4.1.3052.18.2.2.5.1.27 displaystring read-write
Conversion high unit value for this analog input sensor
                       espcAIConvLowValue 1.3.6.1.4.1.3052.18.2.2.5.1.29 displaystring read-write
Conversion low value for this analog input sensor
                       espcAIConvLowUnit 1.3.6.1.4.1.3052.18.2.2.5.1.30 displaystring read-write
Conversion unit low unit value for this analog input sensor
                       espcAIDisplayFormat 1.3.6.1.4.1.3052.18.2.2.5.1.32 displaystring read-write
Analog input display format
               esPointConfigOutputTable 1.3.6.1.4.1.3052.18.2.2.6 no-access
This table organizes configuration items for output points. A point is a particular sensor on an EventSensor. The 3 point attributes organized in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this output config table ; namely, which EventSensor and which sensor.
                   esPointConfigOutputEntry 1.3.6.1.4.1.3052.18.2.2.6.1 no-access
Entry for EventSensor point config output table
                       espcOutputIndexES 1.3.6.1.4.1.3052.18.2.2.6.1.1 integer32 read-only
The part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.
                       espcOutputIndexPoint 1.3.6.1.4.1.3052.18.2.2.6.1.2 integer32 read-only
The part of the point index that delineates which sensor on the EventSensor. So this combined with espcOutputIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of output point configuration.
                       espcOutputEnable 1.3.6.1.4.1.3052.18.2.2.6.1.3 displaystring read-write
Enables the output event for this output. This has no effect on whether the relay changes state, only on whether a state change triggers an event.
                       espcOutputActiveState 1.3.6.1.4.1.3052.18.2.2.6.1.4 displaystring read-write
Which state is considered the active state: energized/de-energized.
                       espcOutputType 1.3.6.1.4.1.3052.18.2.2.6.1.5 displaystring read-only
Output type: RELAY, POWER, SSR, TTL.
                       espcOutputAliasValue 1.3.6.1.4.1.3052.18.2.2.6.1.6 displaystring read-only
Output alias corresponding to its event state.
                       espcOutputAliasColor 1.3.6.1.4.1.3052.18.2.2.6.1.7 displaystring read-only
Output color corresponding to its event state.
                       espcOutputActiveAlias 1.3.6.1.4.1.3052.18.2.2.6.1.10 displaystring read-write
Alias for the output active state.
                       espcOutputActiveColor 1.3.6.1.4.1.3052.18.2.2.6.1.11 displaystring read-write
Output color (as rendered in the web UI, in RGB hex format) corresponding to the output active state.
                       espcOutputActiveActions 1.3.6.1.4.1.3052.18.2.2.6.1.12 displaystring read-write
Actions for the output active event.
                       espcOutputActiveTrapnum 1.3.6.1.4.1.3052.18.2.2.6.1.13 integer32 read-write
Actions for the output active event.
                       espcOutputActiveClass 1.3.6.1.4.1.3052.18.2.2.6.1.14 displaystring read-write
Class (severity) for the output active event.
                       espcOutputInactiveAlias 1.3.6.1.4.1.3052.18.2.2.6.1.20 displaystring read-write
Alias for the output inactive state.
                       espcOutputInactiveColor 1.3.6.1.4.1.3052.18.2.2.6.1.21 displaystring read-write
Output color (as rendered in the web UI, in RGB hex format) corresponding to the output inactive state.
                       espcOutputInactiveActions 1.3.6.1.4.1.3052.18.2.2.6.1.22 displaystring read-write
Actions for the output inactive event.
                       espcOutputInactiveTrapnum 1.3.6.1.4.1.3052.18.2.2.6.1.23 integer32 read-write
Actions for the output inactive event.
                       espcOutputInactiveClass 1.3.6.1.4.1.3052.18.2.2.6.1.24 displaystring read-write
Class (severity) for the output inactive event.
           serialPorts 1.3.6.1.4.1.3052.18.2.3
               numberPorts 1.3.6.1.4.1.3052.18.2.3.1 integer32 read-only
Number of RS-232 ports found. Range: 2 or 4
               portConfigTable 1.3.6.1.4.1.3052.18.2.3.2 no-access
Port config table
                   portConfigEntry 1.3.6.1.4.1.3052.18.2.3.2.1 no-access
Port config entry
                       portConfigIndex 1.3.6.1.4.1.3052.18.2.3.2.1.1 integer32 read-only
Index for ports
                       portConfigBaud 1.3.6.1.4.1.3052.18.2.3.2.1.2 integer32 read-write
Baud rate, 19200, 9600, etc.
                       portConfigDataFormat 1.3.6.1.4.1.3052.18.2.3.2.1.3 integer32 read-write
Value representing word length, parity, and stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2
                       portConfigStripPtOutputLfs 1.3.6.1.4.1.3052.18.2.3.2.1.4 integer32 read-write
Strip passthrough LFs sent to device on this port: 1=yes, 0=no.
                       portConfigStripPtInputLfs 1.3.6.1.4.1.3052.18.2.3.2.1.5 integer32 read-write
Strip passthrough LFs received from device on this port: 1=yes, 0=no.
                       portConfigId 1.3.6.1.4.1.3052.18.2.3.2.1.27 displaystring read-write
The text identifer for the port
                       portConfigMode 1.3.6.1.4.1.3052.18.2.3.2.1.28 displaystring read-write
Mode of the serial port.
                       portConfigHsk 1.3.6.1.4.1.3052.18.2.3.2.1.29 displaystring read-write
Handshaking mode of the serial port.
           network 1.3.6.1.4.1.3052.18.2.4
               interface 1.3.6.1.4.1.3052.18.2.4.1
                   ethernet 1.3.6.1.4.1.3052.18.2.4.1.1
                       ethernet1 1.3.6.1.4.1.3052.18.2.4.1.1.1
                           eth1Mode 1.3.6.1.4.1.3052.18.2.4.1.1.1.1 displaystring read-only
Mode of the Ethernet1 interface: STATIC,DHCP,VLAN
                           eth1Address 1.3.6.1.4.1.3052.18.2.4.1.1.1.2 ipaddress read-write
Ethernet1 IP address
                           eth1SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.1.3 ipaddress read-write
Ethernet1 subnet mask
                           eth1Router 1.3.6.1.4.1.3052.18.2.4.1.1.1.4 ipaddress read-write
Ethernet1 router
                           eth1VLAN 1.3.6.1.4.1.3052.18.2.4.1.1.1.5
                               eth1VLAN1 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1
                                   eth1VLAN1ID 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.1 integer32 read-write
Ethernet1 VLAN1 ID
                                   eth1VLAN1Priority 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.2 integer32 read-write
Ethernet1 VLAN1 priority
                                   eth1VLAN1Address 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.3 ipaddress read-write
Ethernet1 VLAN1 IP address
                                   eth1VLAN1SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.4 ipaddress read-write
Ethernet1 VLAN1 subnet mask
                                   eth1VLAN1Router 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.1.5 ipaddress read-write
Ethernet1 VLAN1 router
                               eth1VLAN2 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2
                                   eth1VLAN2ID 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.1 integer32 read-write
Ethernet1 VLAN2 ID
                                   eth1VLAN2Priority 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.2 integer32 read-write
Ethernet1 VLAN2 priority
                                   eth1VLAN2Address 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.3 ipaddress read-write
Ethernet1 VLAN2 IP address
                                   eth1VLAN2SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.4 ipaddress read-write
Ethernet1 VLAN2 subnet mask
                                   eth1VLAN2Router 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.2.5 ipaddress read-write
Ethernet1 VLAN2 router
                               eth1VLAN3 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3
                                   eth1VLAN3ID 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.1 integer32 read-write
Ethernet1 VLAN3 ID
                                   eth1VLAN3Priority 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.2 integer32 read-write
Ethernet1 VLAN3 priority
                                   eth1VLAN3Address 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.3 ipaddress read-write
Ethernet1 VLAN3 IP address
                                   eth1VLAN3SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.4 ipaddress read-write
Ethernet1 VLAN3 subnet mask
                                   eth1VLAN3Router 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.3.5 ipaddress read-write
Ethernet1 VLAN3 router
                               eth1VLAN4 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4
                                   eth1VLAN4ID 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.1 integer32 read-write
Ethernet1 VLAN4 ID
                                   eth1VLAN4Priority 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.2 integer32 read-write
Ethernet1 VLAN4 priority
                                   eth1VLAN4Address 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.3 ipaddress read-write
Ethernet1 VLAN4 IP address
                                   eth1VLAN4SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.4 ipaddress read-write
Ethernet1 VLAN4 subnet mask
                                   eth1VLAN4Router 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.4.5 ipaddress read-write
Ethernet1 VLAN4 router
                               eth1VLAN5 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5
                                   eth1VLAN5ID 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.1 integer32 read-write
Ethernet1 VLAN5 ID
                                   eth1VLAN5Priority 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.2 integer32 read-write
Ethernet1 VLAN5 priority
                                   eth1VLAN5Address 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.3 ipaddress read-write
Ethernet1 VLAN5 IP address
                                   eth1VLAN5SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.4 ipaddress read-write
Ethernet1 VLAN5 subnet mask
                                   eth1VLAN5Router 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.5.5 ipaddress read-write
Ethernet1 VLAN5 router
                               eth1VLAN6 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6
                                   eth1VLAN6ID 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.1 integer32 read-write
Ethernet1 VLAN6 ID
                                   eth1VLAN6Priority 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.2 integer32 read-write
Ethernet1 VLAN6 priority
                                   eth1VLAN6Address 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.3 ipaddress read-write
Ethernet1 VLAN6 IP address
                                   eth1VLAN6SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.4 ipaddress read-write
Ethernet1 VLAN6 subnet mask
                                   eth1VLAN6Router 1.3.6.1.4.1.3052.18.2.4.1.1.1.5.6.5 ipaddress read-write
Ethernet1 VLAN6 router
                           eth1MAC 1.3.6.1.4.1.3052.18.2.4.1.1.1.6 displaystring read-only
Ethernet1 MAC
                           eth1IPv6 1.3.6.1.4.1.3052.18.2.4.1.1.1.7
                               eth1IPv6Mode 1.3.6.1.4.1.3052.18.2.4.1.1.1.7.1 displaystring read-write
Controls IPv6 operation for this Ethernet interface.
                               eth1IPv6Static 1.3.6.1.4.1.3052.18.2.4.1.1.1.7.2
                                   eth1IPv6StaticAddress 1.3.6.1.4.1.3052.18.2.4.1.1.1.7.2.1 displaystring read-write
he static IPv6 address to use for this interface when in operating in STATIC mode.
                                   eth1IPv6StaticRouter 1.3.6.1.4.1.3052.18.2.4.1.1.1.7.2.2 displaystring read-write
The IPv6 router to engage as the default router when this interface operates in STATIC mode.
                               eth1IPv6Auto 1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3
                                   eth1IPv6AutoAddress1 1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.1 displaystring read-only
One of the automatically-acquired IPv6 addresses.
                                   eth1IPv6AutoAddress2 1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.2 displaystring read-only
One of the automatically-acquired IPv6 addresses.
                                   eth1IPv6AutoAddress3 1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.3 displaystring read-only
One of the automatically-acquired IPv6 addresses.
                                   eth1IPv6AutoAddress4 1.3.6.1.4.1.3052.18.2.4.1.1.1.7.3.4 displaystring read-only
One of the automatically-acquired IPv6 addresses.
                               eth1IPv6LinkLocalAddress 1.3.6.1.4.1.3052.18.2.4.1.1.1.7.4 displaystring read-only
The link local IPv6 address for this interface. This is present when the IPv6 mode is not OFF.
                       ethernet2 1.3.6.1.4.1.3052.18.2.4.1.1.2
                           eth2Mode 1.3.6.1.4.1.3052.18.2.4.1.1.2.1 displaystring read-only
Mode of the Ethernet2 interface: STATIC,DHCP,VLAN
                           eth2Address 1.3.6.1.4.1.3052.18.2.4.1.1.2.2 ipaddress read-write
Ethernet2 IP address
                           eth2SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.2.3 ipaddress read-write
Ethernet2 subnet mask
                           eth2Router 1.3.6.1.4.1.3052.18.2.4.1.1.2.4 ipaddress read-write
Ethernet2 router
                           eth2VLAN 1.3.6.1.4.1.3052.18.2.4.1.1.2.5
                               eth2VLAN1 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1
                                   eth2VLAN1ID 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.1 integer32 read-write
Ethernet2 VLAN1 ID
                                   eth2VLAN1Priority 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.2 integer32 read-write
Ethernet2 VLAN1 priority
                                   eth2VLAN1Address 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.3 ipaddress read-write
Ethernet2 VLAN1 IP address
                                   eth2VLAN1SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.4 ipaddress read-write
Ethernet2 VLAN1 subnet mask
                                   eth2VLAN1Router 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.1.5 ipaddress read-write
Ethernet2 VLAN1 router
                               eth2VLAN2 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2
                                   eth2VLAN2ID 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.1 integer32 read-write
Ethernet2 VLAN2 ID
                                   eth2VLAN2Priority 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.2 integer32 read-write
Ethernet2 VLAN2 priority
                                   eth2VLAN2Address 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.3 ipaddress read-write
Ethernet2 VLAN2 IP address
                                   eth2VLAN2SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.4 ipaddress read-write
Ethernet2 VLAN2 subnet mask
                                   eth2VLAN2Router 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.2.5 ipaddress read-write
Ethernet2 VLAN2 router
                               eth2VLAN3 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3
                                   eth2VLAN3ID 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.1 integer32 read-write
Ethernet2 VLAN3 ID
                                   eth2VLAN3Priority 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.2 integer32 read-write
Ethernet2 VLAN3 priority
                                   eth2VLAN3Address 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.3 ipaddress read-write
Ethernet2 VLAN3 IP address
                                   eth2VLAN3SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.4 ipaddress read-write
Ethernet2 VLAN3 subnet mask
                                   eth2VLAN3Router 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.3.5 ipaddress read-write
Ethernet2 VLAN3 router
                               eth2VLAN4 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4
                                   eth2VLAN4ID 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.1 integer32 read-write
Ethernet2 VLAN4 ID
                                   eth2VLAN4Priority 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.2 integer32 read-write
Ethernet2 VLAN4 priority
                                   eth2VLAN4Address 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.3 ipaddress read-write
Ethernet2 VLAN4 IP address
                                   eth2VLAN4SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.4 ipaddress read-write
Ethernet2 VLAN4 subnet mask
                                   eth2VLAN4Router 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.4.5 ipaddress read-write
Ethernet2 VLAN4 router
                               eth2VLAN5 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5
                                   eth2VLAN5ID 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.1 integer32 read-write
Ethernet2 VLAN5 ID
                                   eth2VLAN5Priority 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.2 integer32 read-write
Ethernet2 VLAN5 priority
                                   eth2VLAN5Address 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.3 ipaddress read-write
Ethernet2 VLAN5 IP address
                                   eth2VLAN5SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.4 ipaddress read-write
Ethernet2 VLAN5 subnet mask
                                   eth2VLAN5Router 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.5.5 ipaddress read-write
Ethernet2 VLAN5 router
                               eth2VLAN6 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6
                                   eth2VLAN6ID 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.1 integer32 read-write
Ethernet2 VLAN6 ID
                                   eth2VLAN6Priority 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.2 integer32 read-write
Ethernet2 VLAN6 priority
                                   eth2VLAN6Address 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.3 ipaddress read-write
Ethernet2 VLAN6 IP address
                                   eth2VLAN6SubnetMask 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.4 ipaddress read-write
Ethernet2 VLAN6 subnet mask
                                   eth2VLAN6Router 1.3.6.1.4.1.3052.18.2.4.1.1.2.5.6.5 ipaddress read-write
Ethernet2 VLAN6 router
                           eth2MAC 1.3.6.1.4.1.3052.18.2.4.1.1.2.6 displaystring read-only
Ethernet2 MAC
                           eth2IPv6 1.3.6.1.4.1.3052.18.2.4.1.1.2.7
                               eth2IPv6Mode 1.3.6.1.4.1.3052.18.2.4.1.1.2.7.1 displaystring read-write
Controls IPv6 operation for this Ethernet interface.
                               eth2IPv6Static 1.3.6.1.4.1.3052.18.2.4.1.1.2.7.2
                                   eth2IPv6StaticAddress 1.3.6.1.4.1.3052.18.2.4.1.1.2.7.2.1 displaystring read-write
he static IPv6 address to use for this interface when in operating in STATIC mode.
                                   eth2IPv6StaticRouter 1.3.6.1.4.1.3052.18.2.4.1.1.2.7.2.2 displaystring read-write
The IPv6 router to engage as the default router when this interface operates in STATIC mode.
                               eth2IPv6Auto 1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3
                                   eth2IPv6AutoAddress1 1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.1 displaystring read-only
One of the automatically-acquired IPv6 addresses.
                                   eth2IPv6AutoAddress2 1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.2 displaystring read-only
One of the automatically-acquired IPv6 addresses.
                                   eth2IPv6AutoAddress3 1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.3 displaystring read-only
One of the automatically-acquired IPv6 addresses.
                                   eth2IPv6AutoAddress4 1.3.6.1.4.1.3052.18.2.4.1.1.2.7.3.4 displaystring read-only
One of the automatically-acquired IPv6 addresses.
                               eth2IPv6LinkLocalAddress 1.3.6.1.4.1.3052.18.2.4.1.1.2.7.4 displaystring read-only
The link local IPv6 address for this interface. This is present when the IPv6 mode is not OFF.
               defaultRouter 1.3.6.1.4.1.3052.18.2.4.2 displaystring read-write
The default router/gateway
               dnsTable 1.3.6.1.4.1.3052.18.2.4.3 no-access
DNS server address table
                   dnsEntry 1.3.6.1.4.1.3052.18.2.4.3.1 no-access
DNS server address entry
                       dnsIndex 1.3.6.1.4.1.3052.18.2.4.3.1.1 integer32 read-only
Index for DNS server address
                       dnsAddress 1.3.6.1.4.1.3052.18.2.4.3.1.2 ipaddress read-write
DNS server address
               hostname 1.3.6.1.4.1.3052.18.2.4.4 displaystring read-write
The hostname of the unit
               hostTable 1.3.6.1.4.1.3052.18.2.4.5 no-access
Static host table
                   hostEntry 1.3.6.1.4.1.3052.18.2.4.5.1 no-access
Static host entry
                       hostIndex 1.3.6.1.4.1.3052.18.2.4.5.1.1 integer32 read-only
Index for static host
                       hostDeclaration 1.3.6.1.4.1.3052.18.2.4.5.1.2 displaystring read-write
Static host declaration string (i.e. 'address hostname')
               ncpDuplex 1.3.6.1.4.1.3052.18.2.4.6 integer32 read-write
For network command processor: 1=Input characters are echoed; 0=no echo.
               ncpTimeout 1.3.6.1.4.1.3052.18.2.4.7 integer32 read-write
Network command processor inactivity timeout
               snmp 1.3.6.1.4.1.3052.18.2.4.8
                   snmpAgentEnable 1.3.6.1.4.1.3052.18.2.4.8.1 displaystring read-write
ON/OFF for snmp agent
                   snmpNotificationTx 1.3.6.1.4.1.3052.18.2.4.8.7
                       snmpNtfnAttempts 1.3.6.1.4.1.3052.18.2.4.8.7.1 integer32 read-write
Maximum of times the unit attempts to send a notification (trap/inform) in 1 cycle
                       snmpNtfnTimeout 1.3.6.1.4.1.3052.18.2.4.8.7.2 integer32 read-write
Number of seconds between retries of sending a notification
                       snmpNtfnCycles 1.3.6.1.4.1.3052.18.2.4.8.7.3 integer32 read-write
Number of times the unit attempts a group of attempts to send a notification (a cycle)
                       snmpNtfnSnooze 1.3.6.1.4.1.3052.18.2.4.8.7.4 integer32 read-write
Minutes between cycles
                   snmpProxy 1.3.6.1.4.1.3052.18.2.4.8.8
                       snmpProxyTable 1.3.6.1.4.1.3052.18.2.4.8.8.1 no-access
Table of SNMP proxy entries
                           snmpProxyEntry 1.3.6.1.4.1.3052.18.2.4.8.8.1.1 no-access
Entry for SNMP proxy table
                               snmpProxyIndex 1.3.6.1.4.1.3052.18.2.4.8.8.1.1.1 integer32 read-only
Index for SNMP proxy table
                               snmpProxyEgressOIDBranch 1.3.6.1.4.1.3052.18.2.4.8.8.1.1.2 displaystring read-write
The OID branch to trigger the proxy function. This should cover the device to proxy. If blank then this proxy entry is disabled.
                               snmpProxyIP 1.3.6.1.4.1.3052.18.2.4.8.8.1.1.3 displaystring read-write
The IP address of the device to proxy.
                               snmpProxyPort 1.3.6.1.4.1.3052.18.2.4.8.8.1.1.4 integer32 read-write
The UDP port on which the device to proxy listens.
                               snmpProxyIngressOIDBranch 1.3.6.1.4.1.3052.18.2.4.8.8.1.1.5 displaystring read-write
The OID branch to be remapped to egress OID branch to trigger the proxy function. If blank then the egress OID branch is proxied without remapping.
                               snmpProxyName 1.3.6.1.4.1.3052.18.2.4.8.8.1.1.6 displaystring read-write
Name of this proxy entry.
                   snmpPoll 1.3.6.1.4.1.3052.18.2.4.8.9
                       snmpPMode 1.3.6.1.4.1.3052.18.2.4.8.9.1 displaystring read-write
Mode of poll operation: OFF or POLL ONLY (just make the results available to view).
                       snmpPRequestTable 1.3.6.1.4.1.3052.18.2.4.8.9.4 no-access
Table of SNMP Poll requests.
                           snmpPRequestEntry 1.3.6.1.4.1.3052.18.2.4.8.9.4.1 no-access
Entry for table pf SNMP Poll requests.
                               snmpPRequestIndex 1.3.6.1.4.1.3052.18.2.4.8.9.4.1.1 integer32 read-only
Index for table of SNMP Poll requests.
                               snmpPRequestDescription 1.3.6.1.4.1.3052.18.2.4.8.9.4.1.2 displaystring read-write
A description for this single telemetry request; no functional effect.
                               snmpPRequestAgent 1.3.6.1.4.1.3052.18.2.4.8.9.4.1.3 displaystring read-write
SNMP Agent IP address or hostname for this single telemetry request.
                               snmpPRequestReadcom 1.3.6.1.4.1.3052.18.2.4.8.9.4.1.4 displaystring read-write
SNMP read community for this single telemetry request.
                               snmpPRequestOID 1.3.6.1.4.1.3052.18.2.4.8.9.4.1.5 displaystring read-write
SNMP object identifier for this single telemetry request.
                               snmpPRequestPeriod 1.3.6.1.4.1.3052.18.2.4.8.9.4.1.6 integer32 read-write
How many seconds between periodic SNMP polls of this single telemetry request.
                               snmpPRequestResultStatus 1.3.6.1.4.1.3052.18.2.4.8.9.4.1.10 displaystring read-only
Status of the last attempt for this telemetry request.
                               snmpPRequestResultValue 1.3.6.1.4.1.3052.18.2.4.8.9.4.1.11 displaystring read-only
The telemetry value if the last request was successful.
                               snmpPRequestResultTime 1.3.6.1.4.1.3052.18.2.4.8.9.4.1.12 displaystring read-only
The timestamp of the last telemetry request.
                               snmpPRequestResultType 1.3.6.1.4.1.3052.18.2.4.8.9.4.1.13 displaystring read-only
The type of the telemetry as reported by the agent.
               ftpPush 1.3.6.1.4.1.3052.18.2.4.9
                   ftpPushEnable 1.3.6.1.4.1.3052.18.2.4.9.1 displaystring read-write
Enable FTP push for REGULAR (protocol: FTP) or SECURE (protocol: SFTP) operation, or disable it (OFF)
                   ftpPushServer 1.3.6.1.4.1.3052.18.2.4.9.2 displaystring read-write
FTP server to which data should be pushed
                   ftpPushAccount 1.3.6.1.4.1.3052.18.2.4.9.5 displaystring read-write
FTP push account
                   ftpPushDirectory 1.3.6.1.4.1.3052.18.2.4.9.6 displaystring read-write
FTP push directory
                   ftpPushperiod 1.3.6.1.4.1.3052.18.2.4.9.7 integer32 read-write
Minutes between pushes
                   ftpPushPushFileTable 1.3.6.1.4.1.3052.18.2.4.9.8 no-access
Table of files to push
                       ftpPushPushFileEntry 1.3.6.1.4.1.3052.18.2.4.9.8.1 no-access
Entry for table of files to push
                           ftpPushPushFileIndex 1.3.6.1.4.1.3052.18.2.4.9.8.1.1 integer32 read-only
Index for table of files to push
                           ftpPushPushFile 1.3.6.1.4.1.3052.18.2.4.9.8.1.2 displaystring read-write
ON/OFF push this local FILEx
                   ftpPushPushAudit 1.3.6.1.4.1.3052.18.2.4.9.9 displaystring read-write
ON/OFF push the audit log
                   ftpPushPushAlarms 1.3.6.1.4.1.3052.18.2.4.9.10 displaystring read-write
ON/OFF push the alarms/events file
                   ftpPushRemoteFileTable 1.3.6.1.4.1.3052.18.2.4.9.11 no-access
Table of remote names of files to push
                         ftpPushRemoteFileEntry 1.3.6.1.4.1.3052.18.2.4.9.11.1 no-access
Entry for table of remote names of files to push
                             ftpPushRemoteFileIndex 1.3.6.1.4.1.3052.18.2.4.9.11.1.1 integer32 read-only
Index for table of remote names of files to push
                             ftpPushRemoteFileName 1.3.6.1.4.1.3052.18.2.4.9.11.1.2 displaystring read-write
remote name of pushed FILEx (name on server)
                   ftpPushRemoteAlarmName 1.3.6.1.4.1.3052.18.2.4.9.12 displaystring read-write
Filename on server for alarms
                   ftpPushPassive 1.3.6.1.4.1.3052.18.2.4.9.13 displaystring read-write
ON/OFF use ftp passive mode
                   ftpPushIncludeDate 1.3.6.1.4.1.3052.18.2.4.9.14 displaystring read-write
ON/OFF include the date in the name of the pushed file
                   ftpPushIncludeTime 1.3.6.1.4.1.3052.18.2.4.9.15 displaystring read-write
ON/OFF include the time in the name of the pushed file
                   ftpPushIncludeSeq 1.3.6.1.4.1.3052.18.2.4.9.16 displaystring read-write
ON/OFF include a sequence number in the name of the pushed file
                   ftpPushPermissions 1.3.6.1.4.1.3052.18.2.4.9.17 displaystring read-write
Unix permissions to apply to pushed files (octal notation).
               routing 1.3.6.1.4.1.3052.18.2.4.11
                     ethRoutingEnable 1.3.6.1.4.1.3052.18.2.4.11.2 displaystring read-write
ON/OFF unit routes IP traffic from Ethernet to PPP/Wireless
                     ethRoutingNATEnable 1.3.6.1.4.1.3052.18.2.4.11.3 displaystring read-write
ON/OFF unit applies NAT on routed IP frames egressing the unit on its PPP interface
               netSecurity 1.3.6.1.4.1.3052.18.2.4.12
                     ipRestriction 1.3.6.1.4.1.3052.18.2.4.12.1
                         ipRestrictionTable 1.3.6.1.4.1.3052.18.2.4.12.1.1 no-access
Table of IP restrictions
                             ipRestrictionEntry 1.3.6.1.4.1.3052.18.2.4.12.1.1.1 no-access
Entry for table of IP restrictions
                                 ipRestrictionIndex 1.3.6.1.4.1.3052.18.2.4.12.1.1.1.1 integer32 read-only
Index for table of IP restrictions
                                 ipRestrictionEnable 1.3.6.1.4.1.3052.18.2.4.12.1.1.1.2 displaystring read-write
ON/OFF enable this IP restriction
                                 ipRestrictionMask 1.3.6.1.4.1.3052.18.2.4.12.1.1.1.3 displaystring read-write
IP restriction mask
               trap 1.3.6.1.4.1.3052.18.2.4.14
                     trapInclude 1.3.6.1.4.1.3052.18.2.4.14.1
                         trapIncludeDateTime 1.3.6.1.4.1.3052.18.2.4.14.1.1 displaystring read-write
ON/OFF include date and time in stock trap message
                         trapIncludeSiteName 1.3.6.1.4.1.3052.18.2.4.14.1.2 displaystring read-write
ON/OFF include site name in stock trap message
                         trapIncludeSensorID 1.3.6.1.4.1.3052.18.2.4.14.1.3 displaystring read-write
ON/OFF include sensor ID in stock trap message
                         trapIncludeUDName 1.3.6.1.4.1.3052.18.2.4.14.1.4 displaystring read-write
ON/OFF include user defined name in stock trap message
                         trapIncludeUDState 1.3.6.1.4.1.3052.18.2.4.14.1.5 displaystring read-write
ON/OFF include user defined state in stock trap message
                         trapIncludeSourceAddress 1.3.6.1.4.1.3052.18.2.4.14.1.6 ipaddress read-write
ON/OFF include source IP address in stock trap message
                     trapAuthFailEnable 1.3.6.1.4.1.3052.18.2.4.14.2 displaystring read-write
ON/OFF enable trap sent upon SNMP authentication failure
               wireless 1.3.6.1.4.1.3052.18.2.4.16
                     wirelessMode 1.3.6.1.4.1.3052.18.2.4.16.1 displaystring read-write
Wireless mode (OFF,PERMANENT-EDGE)
                     wirelessAPN 1.3.6.1.4.1.3052.18.2.4.16.2 displaystring read-write
Wireless access point name
                     wirelessIdleTimeout 1.3.6.1.4.1.3052.18.2.4.16.3 integer32 read-write
Wireless idle timeout
                     wirelessPIN 1.3.6.1.4.1.3052.18.2.4.16.5 displaystring read-write
Wireless modem SIM PIN
                     wirelessDRE 1.3.6.1.4.1.3052.18.2.4.16.9 displaystring read-write
Default route enable for wireless network interface. When this is ON, the wireless link, if up, becomes the default route, overriding the default route setting (defaultRouter object). When OFF, the default route setting controls the default route and the wireless link does not become the default route.
                     wirelessPPPUsername 1.3.6.1.4.1.3052.18.2.4.16.10 displaystring read-write
Username for PPP-based wireless modem connections.
                     wirelessFirewall 1.3.6.1.4.1.3052.18.2.4.16.11 displaystring read-write
Enable wireless modem firewall.
                     wirelessKeepaliveThreshold 1.3.6.1.4.1.3052.18.2.4.16.12 integer32 read-write
Minutes of no RX activity before sending keep-alive.
                     wirelessPPPDebug 1.3.6.1.4.1.3052.18.2.4.16.13 displaystring read-write
Enable wireless modem PPP debug.
                     wirelessConnectivity 1.3.6.1.4.1.3052.18.2.4.16.20
                           wirelessConnEnable 1.3.6.1.4.1.3052.18.2.4.16.20.1 displaystring read-write
Enable wireless modem connectivity check.
                           wirelessConnCheckInterval 1.3.6.1.4.1.3052.18.2.4.16.20.2 integer32 read-write
Wireless connectivity check interval in minutes.
                           wirelessConnFailThreshold 1.3.6.1.4.1.3052.18.2.4.16.20.3 integer32 read-write
Wireless connectivity fail threshold.
                           wirelessConnIP1 1.3.6.1.4.1.3052.18.2.4.16.20.10 ipaddress read-write
Wireless connectivity check IP address 1.
                           wirelessConnIP2 1.3.6.1.4.1.3052.18.2.4.16.20.11 ipaddress read-write
Wireless connectivity check IP address 2.
               email 1.3.6.1.4.1.3052.18.2.4.17
                     emailServer 1.3.6.1.4.1.3052.18.2.4.17.1 displaystring read-write
SMTP server to which the unit sends email
                     emailDomain 1.3.6.1.4.1.3052.18.2.4.17.2 displaystring read-write
Domain to use in recipient address
                     emailAuthEnable 1.3.6.1.4.1.3052.18.2.4.17.3 displaystring read-write
ON/OFF enable SMTP authentication
               netAdvanced 1.3.6.1.4.1.3052.18.2.4.18
                     arpFilter 1.3.6.1.4.1.3052.18.2.4.18.1 integer32 read-write
ARP filter code
               web 1.3.6.1.4.1.3052.18.2.4.19
                     webEnable 1.3.6.1.4.1.3052.18.2.4.19.1 displaystring read-write
ON/OFF for the web interface
                     webPort 1.3.6.1.4.1.3052.18.2.4.19.2 integer32 read-write
TCP port on which web interface listens
                     webTimeout 1.3.6.1.4.1.3052.18.2.4.19.3 integer32 read-write
Web interface session timeout (seconds)
               ipv6 1.3.6.1.4.1.3052.18.2.4.21
                     ipv6DefaultRouter 1.3.6.1.4.1.3052.18.2.4.21.1 displaystring read-write
The IPv6 default router in use.
               cpe 1.3.6.1.4.1.3052.18.2.4.22
                     cpeTable 1.3.6.1.4.1.3052.18.2.4.22.1 no-access
Table of CPEs
                         cpeEntry 1.3.6.1.4.1.3052.18.2.4.22.1.1 no-access
Entry for table of CPEs
                             cpeIndex 1.3.6.1.4.1.3052.18.2.4.22.1.1.1 integer32 read-only
Index for table of CPEs
                             cpeHost 1.3.6.1.4.1.3052.18.2.4.22.1.1.2 displaystring read-write
CPE host (IP address or DNS name)
                             cpeName 1.3.6.1.4.1.3052.18.2.4.22.1.1.3 displaystring read-write
CPE name, informational only
                             cpeDescription 1.3.6.1.4.1.3052.18.2.4.22.1.1.4 displaystring read-write
CPE description, informational only
                             cpeKeepalive 1.3.6.1.4.1.3052.18.2.4.22.1.1.5 integer32 read-write
Number of seconds between each successful ping request.
                             cpeThreshold 1.3.6.1.4.1.3052.18.2.4.22.1.1.6 integer32 read-write
Number of unsuccessful pings that triggers the CPE event.
                             cpeEventReminderInterval 1.3.6.1.4.1.3052.18.2.4.22.1.1.7 integer32 read-write
CPE event reminder interval (minutes).
                             cpeKeepaliveTicks 1.3.6.1.4.1.3052.18.2.4.22.1.1.20 integer32 read-write
CPE ping period in 16ths of a second (nonzero overrides keepalive).
                             cpePingSize 1.3.6.1.4.1.3052.18.2.4.22.1.1.21 integer32 read-write
Number of bytes in CPE ping payload
                             cpeInfoReset 1.3.6.1.4.1.3052.18.2.4.22.1.1.30 integer32 read-write
Set any number to reset CPE ping stats.
                             cpeInfoNumReq 1.3.6.1.4.1.3052.18.2.4.22.1.1.31 integer32 read-only
Total number of requests transmitted.
                             cpeInfoNumGoodResp 1.3.6.1.4.1.3052.18.2.4.22.1.1.32 integer32 read-only
Total number of non-corrupt responses.
                             cpeInfoNumBadResp 1.3.6.1.4.1.3052.18.2.4.22.1.1.33 integer32 read-only
Total number of corrupt responses.
                             cpeInfoNumLostResp 1.3.6.1.4.1.3052.18.2.4.22.1.1.34 integer32 read-only
Total number of requests with no response.
                             cpeInfoPercentLoss 1.3.6.1.4.1.3052.18.2.4.22.1.1.35 displaystring read-only
Percent loss (missing responses / total requests).
                             cpeInfoPercentBad 1.3.6.1.4.1.3052.18.2.4.22.1.1.36 displaystring read-only
Percent corrupt (corrupt responses / total requests).
           time 1.3.6.1.4.1.3052.18.2.8
               clock 1.3.6.1.4.1.3052.18.2.8.1 displaystring read-write
Text string for date and time; e.g. 'SUN 01/02/98 12:34:27'. When setting this object, only the date and time are required; the unit will ignore a specified day of week because it is calculated from the date and time. When this object is included in a notification as a varbind, it represents the time that the triggering event occurred.
           console 1.3.6.1.4.1.3052.18.2.10
                 consoleDuplex 1.3.6.1.4.1.3052.18.2.10.1 displaystring read-write
ON/OFF characters echoed on telnet command session
                 consoleTimeout 1.3.6.1.4.1.3052.18.2.10.2 integer32 read-write
Minutes of inactivity after which telnet command session is terminated
                 consoleConfirm 1.3.6.1.4.1.3052.18.2.10.7 displaystring read-write
ON/OFF Prompt to confirm certain actions
           unitSecurity 1.3.6.1.4.1.3052.18.2.11
                 secCore 1.3.6.1.4.1.3052.18.2.11.1
                     scShowPasswordPrompt 1.3.6.1.4.1.3052.18.2.11.1.1 displaystring read-write
ON/OFF show password prompt upon login
                     scConsoleLoginRequired 1.3.6.1.4.1.3052.18.2.11.1.2 displaystring read-write
ON/OFF login required upon connecting via console
                     scAuthMode 1.3.6.1.4.1.3052.18.2.11.1.7 displaystring read-write
Authentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)
                     scRightsGroup 1.3.6.1.4.1.3052.18.2.11.1.8 displaystring read-write
The set of aliases used for the 8 available rights levels
                     scSecret 1.3.6.1.4.1.3052.18.2.11.1.9 displaystring read-write
Shared secret for challenges
                 secUserTable 1.3.6.1.4.1.3052.18.2.11.2 no-access
Table of users
                     secUserEntry 1.3.6.1.4.1.3052.18.2.11.2.1 no-access
Entry for table of users
                         secUserIndex 1.3.6.1.4.1.3052.18.2.11.2.1.1 integer32 read-only
Index for table of users
                         secUserEnable 1.3.6.1.4.1.3052.18.2.11.2.1.2 displaystring read-write
ON/OFF enable user
                         secUserConnectVia 1.3.6.1.4.1.3052.18.2.11.2.1.5 displaystring read-write
Methods by which user is allowed to connect: L=local (console) T=Telnet F=FTP Ss=SSH W=Web
                         secUserLoginTo 1.3.6.1.4.1.3052.18.2.11.2.1.6 displaystring read-write
The function presented to the user upon login (COMMAND, PASSTHROUGH,MENU)
                         secUserAccessFile 1.3.6.1.4.1.3052.18.2.11.2.1.7 displaystring read-write
The default access file associated with the user
                         secUserPTEscapeTo 1.3.6.1.4.1.3052.18.2.11.2.1.9 displaystring read-write
The function presented to the user upon escaping pass- through: currently only MENU
                         secUserRights 1.3.6.1.4.1.3052.18.2.11.2.1.11 displaystring read-write
The rights level granted to this user
                         secUserEventsReadAccess 1.3.6.1.4.1.3052.18.2.11.2.1.13 displaystring read-write
DENY/ALLOW user to read the events/alarms file
                         secUserAuditReadAccess 1.3.6.1.4.1.3052.18.2.11.2.1.14 displaystring read-write
DENY/ALLOW user to read the audit log
                         secUserEventsWriteAccess 1.3.6.1.4.1.3052.18.2.11.2.1.16 displaystring read-write
DENY/ALLOW user to delete the events file
                         secUserAuditWriteAccess 1.3.6.1.4.1.3052.18.2.11.2.1.17 displaystring read-write
DENY/ALLOW user to write to the audit log
                         secUserExpiration 1.3.6.1.4.1.3052.18.2.11.2.1.18 displaystring read-write
Expiration date/time of this user
                         secUserChallengeConsoleMode 1.3.6.1.4.1.3052.18.2.11.2.1.24 displaystring read-write
Console challenge mode: when user logs in via console, unit allows access (OFF), or presents a challenge (CHALLENGE)
                         secUserChallengeExpiration 1.3.6.1.4.1.3052.18.2.11.2.1.27 integer32 read-write
Time (in minutes) after which a one-time-password is sent that it can be used to log in
                 secFactory 1.3.6.1.4.1.3052.18.2.11.3
                     sfEnable 1.3.6.1.4.1.3052.18.2.11.3.1 displaystring read-write
ON/OFF enable factory access
                     sfSecret 1.3.6.1.4.1.3052.18.2.11.3.2 displaystring read-write
Secret used for factory access
           event 1.3.6.1.4.1.3052.18.2.12
                 evCore 1.3.6.1.4.1.3052.18.2.12.1
                     evClassNameTable 1.3.6.1.4.1.3052.18.2.12.1.1 no-access
Table of classes
                         evClassNameEntry 1.3.6.1.4.1.3052.18.2.12.1.1.1 no-access
Entry for table of classes
                             evClassNameIndex 1.3.6.1.4.1.3052.18.2.12.1.1.1.1 integer32 read-only
Index for table of classes
                             evClassName 1.3.6.1.4.1.3052.18.2.12.1.1.1.2 displaystring read-write
Class name for this slot
                     evReminderInterval 1.3.6.1.4.1.3052.18.2.12.1.2 integer32 read-write
Interval (minutes) between EventSensor reminder events
                     evLog 1.3.6.1.4.1.3052.18.2.12.1.3
                         evLogEnable 1.3.6.1.4.1.3052.18.2.12.1.3.1 displaystring read-write
ON/OFF enable event log
                         evLogStoreAlarm 1.3.6.1.4.1.3052.18.2.12.1.3.2 displaystring read-write
ON/OFF store data alarms in event log
                         evLogMaxSize 1.3.6.1.4.1.3052.18.2.12.1.3.3 integer32 read-write
max size (in KB) of event log
                         evLogStoreSensor 1.3.6.1.4.1.3052.18.2.12.1.3.4 displaystring read-write
ON/OFF store EventSensor events in event log
                         evLogTimeStampAlarms 1.3.6.1.4.1.3052.18.2.12.1.3.5 displaystring read-write
ON/OFF put timestamps on event log entries
                         evLogPrependName 1.3.6.1.4.1.3052.18.2.12.1.3.6 displaystring read-write
ON/OFF prepend data event name to data alarm records in event log
                     evMgmt 1.3.6.1.4.1.3052.18.2.12.1.4
                         evMgmtReprocess 1.3.6.1.4.1.3052.18.2.12.1.4.3 displaystring read-write
Number of sensors that have generated events since reset. Write this to reprocess each sensor's last generated event since reset. The value to write determines what kind of events should be reprocessed: 'all': all sensor events 'cc': cc events 'temperature': temperature events 'humidity': humidity events 'analog': analog input events 'fuel': fuel sensor events 'acpm': AC power monitor events 'battery': battery monitor events
                 evSched1 1.3.6.1.4.1.3052.18.2.12.5
                     evSched1Enable 1.3.6.1.4.1.3052.18.2.12.5.1 displaystring read-write
ON/OFF enable this scheduled event
                     evSched1Actions 1.3.6.1.4.1.3052.18.2.12.5.2 displaystring read-write
Actions for this scheduled event
                     evSched1Message 1.3.6.1.4.1.3052.18.2.12.5.3 displaystring read-write
Message for this scheduled event
                     evSched1TrapNum 1.3.6.1.4.1.3052.18.2.12.5.4 integer32 read-write
Trap number for this scheduled event
                     evSched1Class 1.3.6.1.4.1.3052.18.2.12.5.5 displaystring read-write
Class for this scheduled event
                     evSched1Sunday 1.3.6.1.4.1.3052.18.2.12.5.6 displaystring read-write
Time on Sunday (HH:MM) when this scheduled event triggers
                     evSched1Monday 1.3.6.1.4.1.3052.18.2.12.5.7 displaystring read-write
Time on Monday (HH:MM) when this scheduled event triggers
                     evSched1Tuesday 1.3.6.1.4.1.3052.18.2.12.5.8 displaystring read-write
Time on Tuesday (HH:MM) when this scheduled event triggers
                     evSched1Wednesday 1.3.6.1.4.1.3052.18.2.12.5.9 displaystring read-write
Time on Wednesday (HH:MM) when this scheduled event triggers
                     evSched1Thursday 1.3.6.1.4.1.3052.18.2.12.5.10 displaystring read-write
Time on Thursday (HH:MM) when this scheduled event triggers
                     evSched1Friday 1.3.6.1.4.1.3052.18.2.12.5.11 displaystring read-write
Time on Friday (HH:MM) when this scheduled event triggers
                     evSched1Saturday 1.3.6.1.4.1.3052.18.2.12.5.12 displaystring read-write
Time on Saturday (HH:MM) when this scheduled event triggers
                     evSched1Exclusions 1.3.6.1.4.1.3052.18.2.12.5.13 displaystring read-write
Exclusions (space-separated MM/DD-formatted dates) for this scheduled event
                 evSched2 1.3.6.1.4.1.3052.18.2.12.6
                     evSched2Enable 1.3.6.1.4.1.3052.18.2.12.6.1 displaystring read-write
ON/OFF enable this scheduled event
                     evSched2Actions 1.3.6.1.4.1.3052.18.2.12.6.2 displaystring read-write
Actions for this scheduled event
                     evSched2Message 1.3.6.1.4.1.3052.18.2.12.6.3 displaystring read-write
Message for this scheduled event
                     evSched2TrapNum 1.3.6.1.4.1.3052.18.2.12.6.4 integer32 read-write
Trap number for this scheduled event
                     evSched2Class 1.3.6.1.4.1.3052.18.2.12.6.5 displaystring read-write
Class for this scheduled event
                     evSched2Sunday 1.3.6.1.4.1.3052.18.2.12.6.6 displaystring read-write
Time on Sunday (HH:MM) when this scheduled event triggers
                     evSched2Monday 1.3.6.1.4.1.3052.18.2.12.6.7 displaystring read-write
Time on Monday (HH:MM) when this scheduled event triggers
                     evSched2Tuesday 1.3.6.1.4.1.3052.18.2.12.6.8 displaystring read-write
Time on Tuesday (HH:MM) when this scheduled event triggers
                     evSched2Wednesday 1.3.6.1.4.1.3052.18.2.12.6.9 displaystring read-write
Time on Wednesday (HH:MM) when this scheduled event triggers
                     evSched2Thursday 1.3.6.1.4.1.3052.18.2.12.6.10 displaystring read-write
Time on Thursday (HH:MM) when this scheduled event triggers
                     evSched2Friday 1.3.6.1.4.1.3052.18.2.12.6.11 displaystring read-write
Time on Friday (HH:MM) when this scheduled event triggers
                     evSched2Saturday 1.3.6.1.4.1.3052.18.2.12.6.12 displaystring read-write
Time on Saturday (HH:MM) when this scheduled event triggers
                     evSched2Exclusions 1.3.6.1.4.1.3052.18.2.12.6.13 displaystring read-write
Exclusions (space-separated MM/DD-formatted dates) for this scheduled event
                 evShskLowTable 1.3.6.1.4.1.3052.18.2.12.7 no-access
Table of serial handshaking low events
                     evShskLowEntry 1.3.6.1.4.1.3052.18.2.12.7.1 no-access
Entry for table of serial handshaking low events
                         evShskLowIndex 1.3.6.1.4.1.3052.18.2.12.7.1.1 integer32 read-only
Index for table of serial handshaking low events
                         evShskLowEnable 1.3.6.1.4.1.3052.18.2.12.7.1.2 displaystring read-write
ON/OFF: enable the serial handshaking low event for this port
                         evShskLowActions 1.3.6.1.4.1.3052.18.2.12.7.1.3 displaystring read-write
Actions for the serial handshaking low event for this port
                         evShskLowMessage 1.3.6.1.4.1.3052.18.2.12.7.1.4 displaystring read-write
Message for the serial handshaking low event for this port
                         evShskLowClass 1.3.6.1.4.1.3052.18.2.12.7.1.5 displaystring read-write
Class for the serial handshaking low event for this port
                         evShskLowTrapNum 1.3.6.1.4.1.3052.18.2.12.7.1.6 integer32 read-write
Trap number for the serial handshaking low event for this port
                 evShskHighTable 1.3.6.1.4.1.3052.18.2.12.8 no-access
Table of serial handshaking high events
                     evShskHighEntry 1.3.6.1.4.1.3052.18.2.12.8.1 no-access
Entry for table of serial handshaking high events
                         evShskHighIndex 1.3.6.1.4.1.3052.18.2.12.8.1.1 integer32 read-only
Index for table of serial handshaking high events
                         evShskHighEnable 1.3.6.1.4.1.3052.18.2.12.8.1.2 displaystring read-write
ON/OFF: enable the serial handshaking high event for this port
                         evShskHighActions 1.3.6.1.4.1.3052.18.2.12.8.1.3 displaystring read-write
Actions for the serial handshaking high event for this port
                         evShskHighMessage 1.3.6.1.4.1.3052.18.2.12.8.1.4 displaystring read-write
Message for the serial handshaking high event for this port
                         evShskHighClass 1.3.6.1.4.1.3052.18.2.12.8.1.5 displaystring read-write
Class for the serial handshaking high event for this port
                         evShskHighTrapNum 1.3.6.1.4.1.3052.18.2.12.8.1.6 integer32 read-write
Trap number for the serial handshaking high event for this port
                 evNoSensor 1.3.6.1.4.1.3052.18.2.12.9
                     evNoSensorTimeout 1.3.6.1.4.1.3052.18.2.12.9.1 integer32 read-write
Timeout (seconds) after which an EventSensor becomes unresponsive that this event is triggered
                     evNoSensorActions 1.3.6.1.4.1.3052.18.2.12.9.2 displaystring read-write
Actions for no sensor event
                     evNoSensorTrapNum 1.3.6.1.4.1.3052.18.2.12.9.3 integer32 read-write
Trap number for no sensor event
                     evNoSensorClass 1.3.6.1.4.1.3052.18.2.12.9.4 displaystring read-write
Class for no sensor event
                 fuelSensor 1.3.6.1.4.1.3052.18.2.12.11
                       fuelSensorGeneralTable 1.3.6.1.4.1.3052.18.2.12.11.1 no-access
This table organizes general fuel sensor attributes.
                           fsGenEntry 1.3.6.1.4.1.3052.18.2.12.11.1.1 no-access
Entry for fuel sensor general config table.
                               fsGenIndex 1.3.6.1.4.1.3052.18.2.12.11.1.1.1 integer32 read-only
Which fuel sensor in the fuel sensor general config table.
                               fsGenName 1.3.6.1.4.1.3052.18.2.12.11.1.1.2 displaystring read-write
Fuel sensor name.
                               fsGenSensorType 1.3.6.1.4.1.3052.18.2.12.11.1.1.3 displaystring read-write
Type of fuel sensor in use; NONE disables the fuel sensor.
                               fsGenDistanceUnit 1.3.6.1.4.1.3052.18.2.12.11.1.1.4 displaystring read-write
Distance units in use when setting and indicating tank dimensions.
                               fsGenRawValueTop 1.3.6.1.4.1.3052.18.2.12.11.1.1.5 displaystring read-write
Analog input reading corresponding to the SENSOR FULL point.
                               fsGenTopOffset 1.3.6.1.4.1.3052.18.2.12.11.1.1.6 displaystring read-write
Distance, in the specified distance unit, between the SENSOR FULL point and the TANK FULL point. The value is positive if the SENSOR FULL point is above the TANK FULL point, and negative if it is below.
                               fsGenRawValueBottom 1.3.6.1.4.1.3052.18.2.12.11.1.1.7 displaystring read-write
Analog input reading corresponding to the minimum fluid height measurable by the fuel sensor.
                               fsGenBottomOffset 1.3.6.1.4.1.3052.18.2.12.11.1.1.8 displaystring read-write
Distance, in the specified distance unit, between the SENSOR EMPTY point and the TANK EMPTY point. The value is positive if the SENSOR EMPTY point is above the TANK EMPTY point, and negative if it is below.
                               fsGenInputES 1.3.6.1.4.1.3052.18.2.12.11.1.1.9 integer32 read-write
Which eventsensor contains the analog input associated with this fuel sensor. Allowed values are 200 (for internal ES), or 1-16.
                               fsGenInputPoint 1.3.6.1.4.1.3052.18.2.12.11.1.1.10 integer32 read-write
Which analog input point, on the specified eventsensor, that is associated with the fuel sensor.
                               fsGenFilterAveraging 1.3.6.1.4.1.3052.18.2.12.11.1.1.11 integer32 read-write
Fuel sensor filter averaging factor.
                               fsGenSysrepEnable 1.3.6.1.4.1.3052.18.2.12.11.1.1.12 displaystring read-write
Fuel sensor System Reporting enable.
                               fsGenSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.11.1.1.13 displaystring read-write
Fuel sensor System Reporting threshold (floating point value).
                               fsGenSysrepLimit 1.3.6.1.4.1.3052.18.2.12.11.1.1.14 integer32 read-write
Fuel sensor System Reporting limit.
                               fsGenSysrepPackage 1.3.6.1.4.1.3052.18.2.12.11.1.1.15 integer32 read-write
Fuel sensor System Reporting package number.
                               fsGenSysrepType 1.3.6.1.4.1.3052.18.2.12.11.1.1.16 displaystring read-write
Fuel sensor ASM profile type.
                               fsGenEnable 1.3.6.1.4.1.3052.18.2.12.11.1.1.17 displaystring read-write
Fuel sensor enable.
                       fuelSensorTankTable 1.3.6.1.4.1.3052.18.2.12.11.2 no-access
This table organizes tank-specific fuel sensor attributes.
                           fsTankEntry 1.3.6.1.4.1.3052.18.2.12.11.2.1 no-access
Entry for fuel sensor tank config table.
                               fsTankIndex 1.3.6.1.4.1.3052.18.2.12.11.2.1.1 integer32 read-only
Which fuel sensor in the fuel sensor tank config table.
                               fsTankHeight 1.3.6.1.4.1.3052.18.2.12.11.2.1.2 displaystring read-write
Height of the tank, from the TANK EMPTY point to the TANK FULL point, in the specified distance unit (i.e. TANK HEIGHT). This is a floating point value.
                               fsTankDimA 1.3.6.1.4.1.3052.18.2.12.11.2.1.3 displaystring read-write
Tank dimension measurement A for certain tank profiles. For HORIZ OVAL, this is the length of the straight section. This is a floating point value.
                               fsTankDimB 1.3.6.1.4.1.3052.18.2.12.11.2.1.4 displaystring read-write
Tank dimension measurement B for certain tank profiles. For HORIZ OVAL, this is the radius of the curved section. This is a floating point value.
                               fsTankVolume 1.3.6.1.4.1.3052.18.2.12.11.2.1.5 displaystring read-write
How many volume units the tank contains, when full. This is a floating point value.
                               fsTankVolumeUnit 1.3.6.1.4.1.3052.18.2.12.11.2.1.6 displaystring read-write
Name of the unit representing fluid volume in the tank. This is only used for display purposes; it does not affect the volume calculation.
                               fsTankShape 1.3.6.1.4.1.3052.18.2.12.11.2.1.7 displaystring read-write
The shape of the fuel tank. A value of LINEAR produces a fluid volume reading that is directly proportional to fluid height. The HORIZ CYL and HORIZ OVAL settings use a hard-coded formula to calculate the volume. The CUSTOM setting uses a strapping table that must be configured as well (see fuelSensorCustomTankTable).
                       fuelSensorCustomTankTable 1.3.6.1.4.1.3052.18.2.12.11.3 no-access
This table organizes the custom tank strapping table. Each fuel sensor has a table of height/volume pairs in service only when the tank shape (fsTankShape) in CUSTOM. This allows the unit to calculate volumes for nonstandard tank shapes, to the degree that accurate height/volume measurements can be configured. This SNMP table has two indexes: the first for which fuel sensor and the second for which height/volume pair.
                           fsCustomTankEntry 1.3.6.1.4.1.3052.18.2.12.11.3.1 no-access
Entry for fuel sensor custom tank config table.
                               fsCustomTankIndexFS 1.3.6.1.4.1.3052.18.2.12.11.3.1.1 integer32 read-only
Which fuel sensor in the fuel sensor tank config table. This is the first of two indexes for this SNMP table.
                               fsCustomTankIndexDatum 1.3.6.1.4.1.3052.18.2.12.11.3.1.2 integer32 read-only
Which hight/volume pair: there are 32 pairs per fuel sensor. This is the second of two indexes for this SNMP table.
                               fsCustomTankHeight 1.3.6.1.4.1.3052.18.2.12.11.3.1.3 displaystring read-write
Height of custom tank height/volume pair. This is a floating point value.
                               fsCustomTankVolume 1.3.6.1.4.1.3052.18.2.12.11.3.1.4 displaystring read-write
Volume of custom tank height/volume pair. This is a floating point value.
                       fuelSensorVolumeTable 1.3.6.1.4.1.3052.18.2.12.11.4 no-access
This table organizes volume-event-specific fuel sensor attributes.
                           fsVolumeEntry 1.3.6.1.4.1.3052.18.2.12.11.4.1 no-access
Entry for fuel sensor volume event config table.
                               fsVolumeIndex 1.3.6.1.4.1.3052.18.2.12.11.4.1.1 integer32 read-only
Which fuel sensor in the fuel sensor volume event config table.
                               fsVolumeEnable 1.3.6.1.4.1.3052.18.2.12.11.4.1.2 displaystring read-write
Enable fuel sensor volume events.
                               fsVolumeDeadband 1.3.6.1.4.1.3052.18.2.12.11.4.1.3 displaystring read-write
Fuel sensor deadband (hysteresis). This is a floating point value.
                               fsVolumeVHighValue 1.3.6.1.4.1.3052.18.2.12.11.4.1.4 displaystring read-write
Fuel sensor volume very high event threshold value. This is a floating point value.
                               fsVolumeVHighActions 1.3.6.1.4.1.3052.18.2.12.11.4.1.5 displaystring read-write
Fuel sensor volume very high event threshold actions.
                               fsVolumeVHighTrapNum 1.3.6.1.4.1.3052.18.2.12.11.4.1.6 integer32 read-write
Fuel sensor volume very high event threshold trap number.
                               fsVolumeVHighClass 1.3.6.1.4.1.3052.18.2.12.11.4.1.7 displaystring read-write
Fuel sensor volume very high event threshold class (severity).
                               fsVolumeHighValue 1.3.6.1.4.1.3052.18.2.12.11.4.1.8 displaystring read-write
Fuel sensor volume high event threshold value. This is a floating point value.
                               fsVolumeHighActions 1.3.6.1.4.1.3052.18.2.12.11.4.1.9 displaystring read-write
Fuel sensor volume high event threshold actions.
                               fsVolumeHighTrapNum 1.3.6.1.4.1.3052.18.2.12.11.4.1.10 integer32 read-write
Fuel sensor volume high event threshold trap number.
                               fsVolumeHighClass 1.3.6.1.4.1.3052.18.2.12.11.4.1.11 displaystring read-write
Fuel sensor volume high event threshold class (severity).
                               fsVolumeNormalActions 1.3.6.1.4.1.3052.18.2.12.11.4.1.12 displaystring read-write
Fuel sensor volume return to normal actions.
                               fsVolumeNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.11.4.1.13 integer32 read-write
Fuel sensor volume return to normal trap number.
                               fsVolumeNormalClass 1.3.6.1.4.1.3052.18.2.12.11.4.1.14 displaystring read-write
Fuel sensor volume return to normal class (severity).
                               fsVolumeLowValue 1.3.6.1.4.1.3052.18.2.12.11.4.1.15 displaystring read-write
Fuel sensor volume low event threshold value. This is a floating point value.
                               fsVolumeLowActions 1.3.6.1.4.1.3052.18.2.12.11.4.1.16 displaystring read-write
Fuel sensor volume low event threshold actions.
                               fsVolumeLowTrapNum 1.3.6.1.4.1.3052.18.2.12.11.4.1.17 integer32 read-write
Fuel sensor volume low event threshold trap number.
                               fsVolumeLowClass 1.3.6.1.4.1.3052.18.2.12.11.4.1.18 displaystring read-write
Fuel sensor volume low event threshold class (severity).
                               fsVolumeVLowValue 1.3.6.1.4.1.3052.18.2.12.11.4.1.19 displaystring read-write
Fuel sensor volume very low event threshold value. This is a floating point value.
                               fsVolumeVLowActions 1.3.6.1.4.1.3052.18.2.12.11.4.1.20 displaystring read-write
Fuel sensor volume very low event threshold actions.
                               fsVolumeVLowTrapNum 1.3.6.1.4.1.3052.18.2.12.11.4.1.21 integer32 read-write
Fuel sensor volume very low event threshold trap number.
                               fsVolumeVLowClass 1.3.6.1.4.1.3052.18.2.12.11.4.1.22 displaystring read-write
Fuel sensor volume very low event threshold class (severity).
                       fuelSensorDisconnectTable 1.3.6.1.4.1.3052.18.2.12.11.5 no-access
This table organizes disconnect-event-specific fuel sensor attributes.
                           fsDiscEntry 1.3.6.1.4.1.3052.18.2.12.11.5.1 no-access
Entry for fuel sensor disconnect event config table.
                               fsDiscIndex 1.3.6.1.4.1.3052.18.2.12.11.5.1.1 integer32 read-only
Which fuel sensor in the fuel sensor disconnect event config table.
                               fsDiscEnable 1.3.6.1.4.1.3052.18.2.12.11.5.1.2 displaystring read-write
Fuel sensor disconnect event enable.
                               fsDiscHighValue 1.3.6.1.4.1.3052.18.2.12.11.5.1.3 displaystring read-write
High end of input value range when fuel sensor is disconnected. This is in the units of the analog input value.
                               fsDiscLowValue 1.3.6.1.4.1.3052.18.2.12.11.5.1.4 displaystring read-write
Low end of input value range when fuel sensor is disconnected. This is in the units of the analog input value.
                               fsDiscActions 1.3.6.1.4.1.3052.18.2.12.11.5.1.5 displaystring read-write
Fuel sensor disconnect event actions.
                               fsDiscTrapNum 1.3.6.1.4.1.3052.18.2.12.11.5.1.6 integer32 read-write
Fuel sensor disconnect event trap number.
                               fsDiscClass 1.3.6.1.4.1.3052.18.2.12.11.5.1.7 displaystring read-write
Fuel sensor disconnect event class (severity).
                               fsDiscNormalActions 1.3.6.1.4.1.3052.18.2.12.11.5.1.8 displaystring read-write
Fuel sensor disconnect return to normal actions.
                               fsDiscNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.11.5.1.9 integer32 read-write
Fuel sensor disconnect return to normal trap number.
                               fsDiscNormalClass 1.3.6.1.4.1.3052.18.2.12.11.5.1.10 displaystring read-write
Fuel sensor disconnect return to normal class (severity).
                       fuelSensorSuddenChangeTable 1.3.6.1.4.1.3052.18.2.12.11.6 no-access
This table organizes sudden-change-event-specific fuel sensor attributes.
                           fsSuddenChangeEntry 1.3.6.1.4.1.3052.18.2.12.11.6.1 no-access
Entry for fuel sensor sudden change event config table.
                               fsSuddenChangeIndex 1.3.6.1.4.1.3052.18.2.12.11.6.1.1 integer32 read-only
Which fuel sensor in the fuel sensor sudden change event config table.
                               fsSuddenChangeEnable 1.3.6.1.4.1.3052.18.2.12.11.6.1.2 displaystring read-write
Fuel volume sudden change event enable.
                               fsSuddenChangeTime 1.3.6.1.4.1.3052.18.2.12.11.6.1.3 integer32 read-write
Fuel volume sudden change event time (minutes): what duration defines 'sudden'.
                               fsSuddenChangeAmplitude 1.3.6.1.4.1.3052.18.2.12.11.6.1.4 displaystring read-write
Fuel volume sudden change event amplitude: what amount (in fuel volume units) over the duration (fsSuddenChangeTime) defines enough change.
                               fsSuddenChangeActions 1.3.6.1.4.1.3052.18.2.12.11.6.1.5 displaystring read-write
Fuel volume sudden change event actions.
                               fsSuddenChangeTrapNum 1.3.6.1.4.1.3052.18.2.12.11.6.1.6 integer32 read-write
Fuel volume sudden change event trap number.
                               fsSuddenChangeClass 1.3.6.1.4.1.3052.18.2.12.11.6.1.7 displaystring read-write
Fuel volume sudden change event class (severity).
                       fuelSensorSlowChangeTable 1.3.6.1.4.1.3052.18.2.12.11.7 no-access
This table organizes slow-change-event-specific fuel sensor attributes.
                           fsSlowChangeEntry 1.3.6.1.4.1.3052.18.2.12.11.7.1 no-access
Entry for fuel sensor slow change event config table.
                               fsSlowChangeIndex 1.3.6.1.4.1.3052.18.2.12.11.7.1.1 integer32 read-only
Which fuel sensor in the fuel sensor slow change event config table.
                               fsSlowChangeEnable 1.3.6.1.4.1.3052.18.2.12.11.7.1.2 displaystring read-write
Fuel volume slow change event enable.
                               fsSlowChangeTime 1.3.6.1.4.1.3052.18.2.12.11.7.1.3 integer32 read-write
Fuel volume slow change event time (minutes): what duration defines 'slow'.
                               fsSlowChangeAmplitude 1.3.6.1.4.1.3052.18.2.12.11.7.1.4 displaystring read-write
Fuel volume slow change event amplitude: what amount (in fuel volume units) over the duration (fsSlowChangeTime) defines enough change.
                               fsSlowChangeActions 1.3.6.1.4.1.3052.18.2.12.11.7.1.5 displaystring read-write
Fuel volume slow change event actions.
                               fsSlowChangeTrapNum 1.3.6.1.4.1.3052.18.2.12.11.7.1.6 integer32 read-write
Fuel volume slow change event trap number.
                               fsSlowChangeClass 1.3.6.1.4.1.3052.18.2.12.11.7.1.7 displaystring read-write
Fuel volume slow change event class (severity).
                       fuelSensorLevelsAutoAdjustTable 1.3.6.1.4.1.3052.18.2.12.11.8 no-access
This table organizes fuel sensor attributes for levels auto-adjustment.
                           fsLAAEntry 1.3.6.1.4.1.3052.18.2.12.11.8.1 no-access
Entry for fuel sensor levels auto-adjust config table.
                               fsLAAIndex 1.3.6.1.4.1.3052.18.2.12.11.8.1.1 integer32 read-only
Which fuel sensor in the fuel sensor levels auto-adjust config table.
                               fsLAAEnable 1.3.6.1.4.1.3052.18.2.12.11.8.1.2 displaystring read-write
Enable fuel sensor levels auto-adjustment.
                               fsLAAEventEnable 1.3.6.1.4.1.3052.18.2.12.11.8.1.3 displaystring read-write
Enable fuel sensor levels auto-adjust event.
                               fsLAAEventThreshold 1.3.6.1.4.1.3052.18.2.12.11.8.1.4 integer32 read-write
Sets level auto-adjust event threshold as percentage of raw value top value. In other words, the event is triggered if the cumulative auto-adjustment, as a percentage of the pre-adjusted value, exceeds this threshold.
                               fsLAAEventActions 1.3.6.1.4.1.3052.18.2.12.11.8.1.5 displaystring read-write
Actions for fuel sensor levels auto-adjust event.
                               fsLAAEventClass 1.3.6.1.4.1.3052.18.2.12.11.8.1.6 displaystring read-write
Class for fuel sensor levels auto-adjust event.
                               fsLAAEventTrapNum 1.3.6.1.4.1.3052.18.2.12.11.8.1.7 integer32 read-write
Trap number for fuel sensor levels auto-adjust event.
                 acPowerMonitor 1.3.6.1.4.1.3052.18.2.12.12
                       acpmGeneralTable 1.3.6.1.4.1.3052.18.2.12.12.1 no-access
This table organizes general AC power monitor attributes.
                           acpmGenEntry 1.3.6.1.4.1.3052.18.2.12.12.1.1 no-access
Entry for AC power monitor general config table.
                               acpmGenIndex 1.3.6.1.4.1.3052.18.2.12.12.1.1.1 integer32 read-only
Which AC power monitor in the AC power monitor general config table.
                               acpmGenDevice 1.3.6.1.4.1.3052.18.2.12.12.1.1.2 displaystring read-write
Model of the AC power monitor device. The unit needs this setting to know which registers to poll for the various data items, among other things.
                               acpmGenName 1.3.6.1.4.1.3052.18.2.12.12.1.1.3 displaystring read-write
Name for the AC power monitor device.
                               acpmGenAddress 1.3.6.1.4.1.3052.18.2.12.12.1.1.4 integer32 read-write
Modbus address of the AC power monitor device.
                               acpmGenPtRatio 1.3.6.1.4.1.3052.18.2.12.12.1.1.5 integer32 read-write
Ratio of secondary turns to primary turns on potential transformers (PT).
                               acpmGenCtRatio 1.3.6.1.4.1.3052.18.2.12.12.1.1.6 integer32 read-write
Ratio of secondary turns to primary turns on current transformers (CT).
                               acpmGenPowerType 1.3.6.1.4.1.3052.18.2.12.12.1.1.7 displaystring read-write
Type of power being monitored.
                               acpmGenSysrepPackage 1.3.6.1.4.1.3052.18.2.12.12.1.1.8 integer32 read-write
System reporting package number.
                               acpmGenSysrepType 1.3.6.1.4.1.3052.18.2.12.12.1.1.9 displaystring read-write
ASM profile type.
                               acpmGenEnable 1.3.6.1.4.1.3052.18.2.12.12.1.1.10 displaystring read-write
AC power monitor enable.
                       acpmAvgVoltageTable 1.3.6.1.4.1.3052.18.2.12.12.2 no-access
This table organizes AC power monitor average voltage attributes.
                           acpmAvgVoltageEntry 1.3.6.1.4.1.3052.18.2.12.12.2.1 no-access
Entry for AC power monitor average voltage config table.
                               acpmAvgVoltageIndex 1.3.6.1.4.1.3052.18.2.12.12.2.1.1 integer32 read-only
Which AC power monitor in the AC power monitor average voltage config table.
                               acpmAvgVoltageEnable 1.3.6.1.4.1.3052.18.2.12.12.2.1.2 displaystring read-write
Enable AC power monitor average voltage events.
                               acpmAvgVoltageDeadband 1.3.6.1.4.1.3052.18.2.12.12.2.1.3 displaystring read-write
Deadband (hysteresis) for average voltage event. This is a floating point value.
                               acpmAvgVoltageVHighValue 1.3.6.1.4.1.3052.18.2.12.12.2.1.4 displaystring read-write
Very high event threshold. This is a floating point value.
                               acpmAvgVoltageVHighActions 1.3.6.1.4.1.3052.18.2.12.12.2.1.5 displaystring read-write
Very high event actions.
                               acpmAvgVoltageVHighTrapNum 1.3.6.1.4.1.3052.18.2.12.12.2.1.6 integer32 read-write
Very high event trap number.
                               acpmAvgVoltageVHighClass 1.3.6.1.4.1.3052.18.2.12.12.2.1.7 displaystring read-write
Very high event class.
                               acpmAvgVoltageHighValue 1.3.6.1.4.1.3052.18.2.12.12.2.1.8 displaystring read-write
High event threshold. This is a floating point value.
                               acpmAvgVoltageHighActions 1.3.6.1.4.1.3052.18.2.12.12.2.1.9 displaystring read-write
High event actions.
                               acpmAvgVoltageHighTrapNum 1.3.6.1.4.1.3052.18.2.12.12.2.1.10 integer32 read-write
High event trap number.
                               acpmAvgVoltageHighClass 1.3.6.1.4.1.3052.18.2.12.12.2.1.11 displaystring read-write
High event class.
                               acpmAvgVoltageNormalActions 1.3.6.1.4.1.3052.18.2.12.12.2.1.12 displaystring read-write
Return to normal actions.
                               acpmAvgVoltageNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.12.2.1.13 integer32 read-write
Return to normal trap number.
                               acpmAvgVoltageNormalClass 1.3.6.1.4.1.3052.18.2.12.12.2.1.14 displaystring read-write
Return to normal class.
                               acpmAvgVoltageLowValue 1.3.6.1.4.1.3052.18.2.12.12.2.1.15 displaystring read-write
Low event threshold. This is a floating point value.
                               acpmAvgVoltageLowActions 1.3.6.1.4.1.3052.18.2.12.12.2.1.16 displaystring read-write
Low event actions.
                               acpmAvgVoltageLowTrapNum 1.3.6.1.4.1.3052.18.2.12.12.2.1.17 integer32 read-write
Low event trap number.
                               acpmAvgVoltageLowClass 1.3.6.1.4.1.3052.18.2.12.12.2.1.18 displaystring read-write
Low event class.
                               acpmAvgVoltageVLowValue 1.3.6.1.4.1.3052.18.2.12.12.2.1.19 displaystring read-write
Very low event threshold. This is a floating point value.
                               acpmAvgVoltageVLowActions 1.3.6.1.4.1.3052.18.2.12.12.2.1.20 displaystring read-write
Very low event actions.
                               acpmAvgVoltageVLowTrapNum 1.3.6.1.4.1.3052.18.2.12.12.2.1.21 integer32 read-write
Very low event trap number.
                               acpmAvgVoltageVLowClass 1.3.6.1.4.1.3052.18.2.12.12.2.1.22 displaystring read-write
Very low event class.
                               acpmAvgVoltageSysrepEnable 1.3.6.1.4.1.3052.18.2.12.12.2.1.23 displaystring read-write
System reporting enable for average voltage telemetry.
                               acpmAvgVoltageSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.12.2.1.24 displaystring read-write
System reporting threshold for average voltage telemetry. This is a floating point value.
                               acpmAvgVoltageSysrepLimit 1.3.6.1.4.1.3052.18.2.12.12.2.1.25 integer32 read-write
System reporting limit for average voltage telemetry.
                       acpmAvgCurrentTable 1.3.6.1.4.1.3052.18.2.12.12.3 no-access
This table organizes AC power monitor average current attributes.
                           acpmAvgCurrentEntry 1.3.6.1.4.1.3052.18.2.12.12.3.1 no-access
Entry for AC power monitor average current config table.
                               acpmAvgCurrentIndex 1.3.6.1.4.1.3052.18.2.12.12.3.1.1 integer32 read-only
Which AC power monitor in the AC power monitor average current config table.
                               acpmAvgCurrentEnable 1.3.6.1.4.1.3052.18.2.12.12.3.1.2 displaystring read-write
Enable AC power monitor average current events.
                               acpmAvgCurrentDeadband 1.3.6.1.4.1.3052.18.2.12.12.3.1.3 displaystring read-write
Deadband (hysteresis) for average current event. This is a floating point value.
                               acpmAvgCurrentVHighValue 1.3.6.1.4.1.3052.18.2.12.12.3.1.4 displaystring read-write
Very high event threshold. This is a floating point value.
                               acpmAvgCurrentVHighActions 1.3.6.1.4.1.3052.18.2.12.12.3.1.5 displaystring read-write
Very high event actions.
                               acpmAvgCurrentVHighTrapNum 1.3.6.1.4.1.3052.18.2.12.12.3.1.6 integer32 read-write
Very high event trap number.
                               acpmAvgCurrentVHighClass 1.3.6.1.4.1.3052.18.2.12.12.3.1.7 displaystring read-write
Very high event class.
                               acpmAvgCurrentHighValue 1.3.6.1.4.1.3052.18.2.12.12.3.1.8 displaystring read-write
High event threshold. This is a floating point value.
                               acpmAvgCurrentHighActions 1.3.6.1.4.1.3052.18.2.12.12.3.1.9 displaystring read-write
High event actions.
                               acpmAvgCurrentHighTrapNum 1.3.6.1.4.1.3052.18.2.12.12.3.1.10 integer32 read-write
High event trap number.
                               acpmAvgCurrentHighClass 1.3.6.1.4.1.3052.18.2.12.12.3.1.11 displaystring read-write
High event class.
                               acpmAvgCurrentNormalActions 1.3.6.1.4.1.3052.18.2.12.12.3.1.12 displaystring read-write
Return to normal actions.
                               acpmAvgCurrentNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.12.3.1.13 integer32 read-write
Return to normal trap number.
                               acpmAvgCurrentNormalClass 1.3.6.1.4.1.3052.18.2.12.12.3.1.14 displaystring read-write
Return to normal class.
                               acpmAvgCurrentLowValue 1.3.6.1.4.1.3052.18.2.12.12.3.1.15 displaystring read-write
Low event threshold. This is a floating point value.
                               acpmAvgCurrentLowActions 1.3.6.1.4.1.3052.18.2.12.12.3.1.16 displaystring read-write
Low event actions.
                               acpmAvgCurrentLowTrapNum 1.3.6.1.4.1.3052.18.2.12.12.3.1.17 integer32 read-write
Low event trap number.
                               acpmAvgCurrentLowClass 1.3.6.1.4.1.3052.18.2.12.12.3.1.18 displaystring read-write
Low event class.
                               acpmAvgCurrentVLowValue 1.3.6.1.4.1.3052.18.2.12.12.3.1.19 displaystring read-write
Very low event threshold. This is a floating point value.
                               acpmAvgCurrentVLowActions 1.3.6.1.4.1.3052.18.2.12.12.3.1.20 displaystring read-write
Very low event actions.
                               acpmAvgCurrentVLowTrapNum 1.3.6.1.4.1.3052.18.2.12.12.3.1.21 integer32 read-write
Very low event trap number.
                               acpmAvgCurrentVLowClass 1.3.6.1.4.1.3052.18.2.12.12.3.1.22 displaystring read-write
Very low event class.
                               acpmAvgCurrentSysrepEnable 1.3.6.1.4.1.3052.18.2.12.12.3.1.23 displaystring read-write
System reporting enable for average current telemetry.
                               acpmAvgCurrentSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.12.3.1.24 displaystring read-write
System reporting threshold for average current telemetry. This is a floating point value.
                               acpmAvgCurrentSysrepLimit 1.3.6.1.4.1.3052.18.2.12.12.3.1.25 integer32 read-write
System reporting limit for average current telemetry.
                       acpmFreqTable 1.3.6.1.4.1.3052.18.2.12.12.4 no-access
This table organizes AC power monitor frequency attributes.
                           acpmFreqEntry 1.3.6.1.4.1.3052.18.2.12.12.4.1 no-access
Entry for AC power monitor frequency config table.
                               acpmFreqIndex 1.3.6.1.4.1.3052.18.2.12.12.4.1.1 integer32 read-only
Which AC power monitor in the AC power monitor frequency config table.
                               acpmFreqEnable 1.3.6.1.4.1.3052.18.2.12.12.4.1.2 displaystring read-write
Enable AC power monitor frequency events.
                               acpmFreqDeadband 1.3.6.1.4.1.3052.18.2.12.12.4.1.3 displaystring read-write
Deadband (hysteresis) for frequency event. This is a floating point value.
                               acpmFreqVHighValue 1.3.6.1.4.1.3052.18.2.12.12.4.1.4 displaystring read-write
Very high event threshold. This is a floating point value.
                               acpmFreqVHighActions 1.3.6.1.4.1.3052.18.2.12.12.4.1.5 displaystring read-write
Very high event actions.
                               acpmFreqVHighTrapNum 1.3.6.1.4.1.3052.18.2.12.12.4.1.6 integer32 read-write
Very high event trap number.
                               acpmFreqVHighClass 1.3.6.1.4.1.3052.18.2.12.12.4.1.7 displaystring read-write
Very high event class.
                               acpmFreqHighValue 1.3.6.1.4.1.3052.18.2.12.12.4.1.8 displaystring read-write
High event threshold. This is a floating point value.
                               acpmFreqHighActions 1.3.6.1.4.1.3052.18.2.12.12.4.1.9 displaystring read-write
High event actions.
                               acpmFreqHighTrapNum 1.3.6.1.4.1.3052.18.2.12.12.4.1.10 integer32 read-write
High event trap number.
                               acpmFreqHighClass 1.3.6.1.4.1.3052.18.2.12.12.4.1.11 displaystring read-write
High event class.
                               acpmFreqNormalActions 1.3.6.1.4.1.3052.18.2.12.12.4.1.12 displaystring read-write
Return to normal actions.
                               acpmFreqNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.12.4.1.13 integer32 read-write
Return to normal trap number.
                               acpmFreqNormalClass 1.3.6.1.4.1.3052.18.2.12.12.4.1.14 displaystring read-write
Return to normal class.
                               acpmFreqLowValue 1.3.6.1.4.1.3052.18.2.12.12.4.1.15 displaystring read-write
Low event threshold. This is a floating point value.
                               acpmFreqLowActions 1.3.6.1.4.1.3052.18.2.12.12.4.1.16 displaystring read-write
Low event actions.
                               acpmFreqLowTrapNum 1.3.6.1.4.1.3052.18.2.12.12.4.1.17 integer32 read-write
Low event trap number.
                               acpmFreqLowClass 1.3.6.1.4.1.3052.18.2.12.12.4.1.18 displaystring read-write
Low event class.
                               acpmFreqVLowValue 1.3.6.1.4.1.3052.18.2.12.12.4.1.19 displaystring read-write
Very low event threshold. This is a floating point value.
                               acpmFreqVLowActions 1.3.6.1.4.1.3052.18.2.12.12.4.1.20 displaystring read-write
Very low event actions.
                               acpmFreqVLowTrapNum 1.3.6.1.4.1.3052.18.2.12.12.4.1.21 integer32 read-write
Very low event trap number.
                               acpmFreqVLowClass 1.3.6.1.4.1.3052.18.2.12.12.4.1.22 displaystring read-write
Very low event class.
                               acpmFreqSysrepEnable 1.3.6.1.4.1.3052.18.2.12.12.4.1.23 displaystring read-write
System reporting enable for frequency telemetry.
                               acpmFreqSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.12.4.1.24 displaystring read-write
System reporting threshold for frequency telemetry. This is a floating point value.
                               acpmFreqSysrepLimit 1.3.6.1.4.1.3052.18.2.12.12.4.1.25 integer32 read-write
System reporting limit for frequency telemetry.
                       acpmTotalRealPowerTable 1.3.6.1.4.1.3052.18.2.12.12.5 no-access
This table organizes AC power monitor total real power attributes.
                           acpmTRPEntry 1.3.6.1.4.1.3052.18.2.12.12.5.1 no-access
Entry for AC power monitor total real power config table.
                               acpmTRPIndex 1.3.6.1.4.1.3052.18.2.12.12.5.1.1 integer32 read-only
Which AC power monitor in the AC power monitor total real power config table.
                               acpmTRPEnable 1.3.6.1.4.1.3052.18.2.12.12.5.1.2 displaystring read-write
Enable AC power monitor total real power events.
                               acpmTRPDeadband 1.3.6.1.4.1.3052.18.2.12.12.5.1.3 displaystring read-write
Deadband (hysteresis) for total real power event. This is a floating point value.
                               acpmTRPVHighValue 1.3.6.1.4.1.3052.18.2.12.12.5.1.4 displaystring read-write
Very high event threshold. This is a floating point value.
                               acpmTRPVHighActions 1.3.6.1.4.1.3052.18.2.12.12.5.1.5 displaystring read-write
Very high event actions.
                               acpmTRPVHighTrapNum 1.3.6.1.4.1.3052.18.2.12.12.5.1.6 integer32 read-write
Very high event trap number.
                               acpmTRPVHighClass 1.3.6.1.4.1.3052.18.2.12.12.5.1.7 displaystring read-write
Very high event class.
                               acpmTRPHighValue 1.3.6.1.4.1.3052.18.2.12.12.5.1.8 displaystring read-write
High event threshold. This is a floating point value.
                               acpmTRPHighActions 1.3.6.1.4.1.3052.18.2.12.12.5.1.9 displaystring read-write
High event actions.
                               acpmTRPHighTrapNum 1.3.6.1.4.1.3052.18.2.12.12.5.1.10 integer32 read-write
High event trap number.
                               acpmTRPHighClass 1.3.6.1.4.1.3052.18.2.12.12.5.1.11 displaystring read-write
High event class.
                               acpmTRPNormalActions 1.3.6.1.4.1.3052.18.2.12.12.5.1.12 displaystring read-write
Return to normal actions.
                               acpmTRPNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.12.5.1.13 integer32 read-write
Return to normal trap number.
                               acpmTRPNormalClass 1.3.6.1.4.1.3052.18.2.12.12.5.1.14 displaystring read-write
Return to normal class.
                               acpmTRPLowValue 1.3.6.1.4.1.3052.18.2.12.12.5.1.15 displaystring read-write
Low event threshold. This is a floating point value.
                               acpmTRPLowActions 1.3.6.1.4.1.3052.18.2.12.12.5.1.16 displaystring read-write
Low event actions.
                               acpmTRPLowTrapNum 1.3.6.1.4.1.3052.18.2.12.12.5.1.17 integer32 read-write
Low event trap number.
                               acpmTRPLowClass 1.3.6.1.4.1.3052.18.2.12.12.5.1.18 displaystring read-write
Low event class.
                               acpmTRPVLowValue 1.3.6.1.4.1.3052.18.2.12.12.5.1.19 displaystring read-write
Very low event threshold. This is a floating point value.
                               acpmTRPVLowActions 1.3.6.1.4.1.3052.18.2.12.12.5.1.20 displaystring read-write
Very low event actions.
                               acpmTRPVLowTrapNum 1.3.6.1.4.1.3052.18.2.12.12.5.1.21 integer32 read-write
Very low event trap number.
                               acpmTRPVLowClass 1.3.6.1.4.1.3052.18.2.12.12.5.1.22 displaystring read-write
Very low event class.
                               acpmTRPSysrepEnable 1.3.6.1.4.1.3052.18.2.12.12.5.1.23 displaystring read-write
System reporting enable for total real power telemetry.
                               acpmTRPSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.12.5.1.24 displaystring read-write
System reporting threshold for total real power telemetry. This is a floating point value.
                               acpmTRPSysrepLimit 1.3.6.1.4.1.3052.18.2.12.12.5.1.25 integer32 read-write
System reporting limit for total real power telemetry.
                       acpmDisconnectTable 1.3.6.1.4.1.3052.18.2.12.12.6 no-access
This table organizes AC power monitor device disconnect event attributes.
                           acpmDisconnectEntry 1.3.6.1.4.1.3052.18.2.12.12.6.1 no-access
Entry for AC power monitor device disconnect event config table.
                               acpmDisconnectIndex 1.3.6.1.4.1.3052.18.2.12.12.6.1.1 integer32 read-only
Which AC power monitor in the AC power monitor device disconnect event config table.
                               acpmDisconnectEnable 1.3.6.1.4.1.3052.18.2.12.12.6.1.2 displaystring read-write
Enable AC power monitor device disconnect event.
                               acpmDisconnectActions 1.3.6.1.4.1.3052.18.2.12.12.6.1.3 displaystring read-write
Actions for disconnect event.
                               acpmDisconnectTrapNum 1.3.6.1.4.1.3052.18.2.12.12.6.1.4 integer32 read-write
Trap number for disconnect event.
                               acpmDisconnectClass 1.3.6.1.4.1.3052.18.2.12.12.6.1.5 displaystring read-write
Class for disconnect event.
                               acpmDisconnectNormalActions 1.3.6.1.4.1.3052.18.2.12.12.6.1.6 displaystring read-write
Actions for disconnect return to normal event.
                               acpmDisconnectNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.12.6.1.7 integer32 read-write
Trap number for disconnect return to normal event.
                               acpmDisconnectNormalClass 1.3.6.1.4.1.3052.18.2.12.12.6.1.8 displaystring read-write
Class for disconnect return to normal event.
                       acpmTotalPowerFactorTable 1.3.6.1.4.1.3052.18.2.12.12.7 no-access
This table organizes AC power monitor device total power factor event attributes.
                           acpmTPFEntry 1.3.6.1.4.1.3052.18.2.12.12.7.1 no-access
Entry for AC power monitor device total power factor event config table.
                               acpmTPFIndex 1.3.6.1.4.1.3052.18.2.12.12.7.1.1 integer32 read-only
Which AC power monitor in the AC power monitor device disconnect event config table.
                               acpmTPFEnable 1.3.6.1.4.1.3052.18.2.12.12.7.1.2 displaystring read-write
Enable AC power monitor device disconnect event.
                               acpmTPFDeadband 1.3.6.1.4.1.3052.18.2.12.12.7.1.3 displaystring read-write
Deadband (hysteresis).
                               acpmTPFNormalActions 1.3.6.1.4.1.3052.18.2.12.12.7.1.4 displaystring read-write
Normal actions.
                               acpmTPFNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.12.7.1.5 integer32 read-write
Normal trap number.
                               acpmTPFNormalClass 1.3.6.1.4.1.3052.18.2.12.12.7.1.6 displaystring read-write
Normal class.
                               acpmTPFLowValue 1.3.6.1.4.1.3052.18.2.12.12.7.1.7 displaystring read-write
Low threshold.
                               acpmTPFLowActions 1.3.6.1.4.1.3052.18.2.12.12.7.1.8 displaystring read-write
Low actions.
                               acpmTPFLowTrapNum 1.3.6.1.4.1.3052.18.2.12.12.7.1.9 integer32 read-write
Low trap number.
                               acpmTPFLowClass 1.3.6.1.4.1.3052.18.2.12.12.7.1.10 displaystring read-write
Low class.
                               acpmTPFVLowValue 1.3.6.1.4.1.3052.18.2.12.12.7.1.11 displaystring read-write
Very Low threshold.
                               acpmTPFVLowActions 1.3.6.1.4.1.3052.18.2.12.12.7.1.12 displaystring read-write
Very Low actions.
                               acpmTPFVLowTrapNum 1.3.6.1.4.1.3052.18.2.12.12.7.1.13 integer32 read-write
Very Low trap number.
                               acpmTPFVLowClass 1.3.6.1.4.1.3052.18.2.12.12.7.1.14 displaystring read-write
Very Low class.
                               acpmTPFSysrepEnable 1.3.6.1.4.1.3052.18.2.12.12.7.1.15 displaystring read-write
System reporting enable.
                               acpmTPFSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.12.7.1.16 displaystring read-write
System reporting threshold.
                               acpmTPFSysrepLimit 1.3.6.1.4.1.3052.18.2.12.12.7.1.17 integer32 read-write
System reporting limit.
                 batteryMonitor 1.3.6.1.4.1.3052.18.2.12.14
                       batteryMonitorGeneralTable 1.3.6.1.4.1.3052.18.2.12.14.1 no-access
This table organizes general battery monitor attributes.
                           bmGenEntry 1.3.6.1.4.1.3052.18.2.12.14.1.1 no-access
Entry for battery monitor general config table.
                               bmGenIndex 1.3.6.1.4.1.3052.18.2.12.14.1.1.1 integer32 read-only
Which battery monitor in the battery monitor general config table.
                               bmGenEnable 1.3.6.1.4.1.3052.18.2.12.14.1.1.2 displaystring read-write
Which battery monitor in the battery monitor general config table.
                               bmGenName 1.3.6.1.4.1.3052.18.2.12.14.1.1.3 displaystring read-write
Name for this battery monitor.
                               bmGenBatteryQuantity 1.3.6.1.4.1.3052.18.2.12.14.1.1.4 integer32 read-write
Number of batteries in the string.
                               bmGenBatteryCapacity 1.3.6.1.4.1.3052.18.2.12.14.1.1.5 integer32 read-write
Capacity of the individual batteries in the string, in amp-hours. A single value applies to all batteries; that is, they are assumed to be all of the same capacity.
                               bmGenBatteryNominalVoltage 1.3.6.1.4.1.3052.18.2.12.14.1.1.6 displaystring read-write
Nominal voltage of the individual batteries in the string, in volts. A single value applies to all batteres; that is, they are assumed to be all of the same voltage. This is a floating point value.
                               bmGenSysrepPackage 1.3.6.1.4.1.3052.18.2.12.14.1.1.7 integer32 read-write
System reporting package number.
                               bmGenSysrepType 1.3.6.1.4.1.3052.18.2.12.14.1.1.8 displaystring read-write
System reporting ASM profile type.
                       batteryMonitorDeviceTable 1.3.6.1.4.1.3052.18.2.12.14.2 no-access
This table organizes temperature battery monitor attributes.
                           bmDeviceEntry 1.3.6.1.4.1.3052.18.2.12.14.2.1 no-access
Entry for battery monitor temperature config table.
                               bmDeviceIndex 1.3.6.1.4.1.3052.18.2.12.14.2.1.1 integer32 read-only
Which battery monitor in the battery monitor device config table.
                               bmDeviceType 1.3.6.1.4.1.3052.18.2.12.14.2.1.2 displaystring read-write
The type of hardware battery monitor unit associated with this battery monitor.
                               bmDeviceES 1.3.6.1.4.1.3052.18.2.12.14.2.1.3 integer32 read-write
The ES index of the hardware battery monitor unit associated with this battery monitor. This setting only pertains to the ES-BMU.
                               bmDeviceIP 1.3.6.1.4.1.3052.18.2.12.14.2.1.4 ipaddress read-write
The IP address of the hardware battery monitor unit associated with this battery monitor.
                               bmDeviceReadcom 1.3.6.1.4.1.3052.18.2.12.14.2.1.5 displaystring read-write
The SNMP read community of the hardware battery monitor unit associated with this battery monitor.
                               bmDeviceInputString 1.3.6.1.4.1.3052.18.2.12.14.2.1.6 integer32 read-write
Which string on the hardware battery monitor unit is associated with this battery monitor.
                               bmDeviceCTSize 1.3.6.1.4.1.3052.18.2.12.14.2.1.7 integer32 read-write
The rating of the DC current sensor, in amperes. If this value is set to 0, then string current will not be measured. This setting only pertains to the ES-BMU.
                       batteryMonitorTempTable 1.3.6.1.4.1.3052.18.2.12.14.3 no-access
This table organizes temperature battery monitor attributes.
                           bmTempEntry 1.3.6.1.4.1.3052.18.2.12.14.3.1 no-access
Entry for battery monitor temperature config table.
                               bmTempIndex 1.3.6.1.4.1.3052.18.2.12.14.3.1.1 integer32 read-only
Which battery monitor in the battery monitor temperature config table.
                               bmTempEnable 1.3.6.1.4.1.3052.18.2.12.14.3.1.2 displaystring read-write
Enable/disable temperature event. This event is based on the average temperature of the jars in the string.
                               bmTempDeadband 1.3.6.1.4.1.3052.18.2.12.14.3.1.3 displaystring read-write
Deadband in degrees F or C, depending on scale setting of sensor referenced by bmGenDeviceES. This is a floating point value.
                               bmTempScale 1.3.6.1.4.1.3052.18.2.12.14.3.1.4 displaystring read-write
Temperature scale; this affects how temperature values are represented, and also how the temperature alarm thresholds and deadbands are interpreted.
                               bmTempHighValue 1.3.6.1.4.1.3052.18.2.12.14.3.1.5 displaystring read-write
Very high event threshold in degrees F or C, depending on scale setting referenced by bmGenDeviceES. This is a floating point value.
                               bmTempHighActions 1.3.6.1.4.1.3052.18.2.12.14.3.1.6 displaystring read-write
Actions for very high temperature event.
                               bmTempHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.3.1.7 integer32 read-write
Trap number for high temperature event.
                               bmTempHighClass 1.3.6.1.4.1.3052.18.2.12.14.3.1.8 displaystring read-write
Class for high temperature event.
                               bmTempNormalActions 1.3.6.1.4.1.3052.18.2.12.14.3.1.9 displaystring read-write
Actions for return to normal temperature event.
                               bmTempNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.14.3.1.10 integer32 read-write
Trap number for return to normal temperature event.
                               bmTempNormalClass 1.3.6.1.4.1.3052.18.2.12.14.3.1.11 displaystring read-write
Class for return to normal temperature event.
                               bmTempLowValue 1.3.6.1.4.1.3052.18.2.12.14.3.1.12 displaystring read-write
Low event threshold in degrees F or C, depending on scale setting. This is a floating point value.
                               bmTempLowActions 1.3.6.1.4.1.3052.18.2.12.14.3.1.13 displaystring read-write
Actions for low temperature event.
                               bmTempLowTrapNum 1.3.6.1.4.1.3052.18.2.12.14.3.1.14 integer32 read-write
Trap number for low temperature event.
                               bmTempLowClass 1.3.6.1.4.1.3052.18.2.12.14.3.1.15 displaystring read-write
Trap number for low temperature event.
                               bmTempSysrepEnable 1.3.6.1.4.1.3052.18.2.12.14.3.1.16 displaystring read-write
System reporting enable for temperature telemetry.
                               bmTempSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.14.3.1.17 displaystring read-write
System reporting threshold for temperature telemetry. This is a floating point value.
                               bmTempSysrepLimit 1.3.6.1.4.1.3052.18.2.12.14.3.1.18 integer32 read-write
System reporting limit for temperature telemetry.
                       batteryMonitorDiffTempTable 1.3.6.1.4.1.3052.18.2.12.14.4 no-access
This table organizes differential temperature battery monitor attributes.
                           bmDiffTempEntry 1.3.6.1.4.1.3052.18.2.12.14.4.1 no-access
Entry for battery monitor differential temperature config table.
                               bmDiffTempIndex 1.3.6.1.4.1.3052.18.2.12.14.4.1.1 integer32 read-only
Which battery monitor in the battery monitor differential temperature config table.
                               bmDiffTempEnable 1.3.6.1.4.1.3052.18.2.12.14.4.1.2 displaystring read-write
Enable/disable differential temperature event. This event is based on the differential between the average temperature of the batteries in the string, and ambient temperature (ambient - string temperature).
                               bmDiffTempDeadband 1.3.6.1.4.1.3052.18.2.12.14.4.1.3 integer32 read-write
Deadband in degrees F or C, depending on scale setting.
                               bmDiffTempVHighValue 1.3.6.1.4.1.3052.18.2.12.14.4.1.4 integer32 read-write
Very high event threshold in degrees F or C, depending on scale setting.
                               bmDiffTempVHighActions 1.3.6.1.4.1.3052.18.2.12.14.4.1.5 displaystring read-write
Actions for very high differential temperature event.
                               bmDiffTempVHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.4.1.6 integer32 read-write
Trap number for very high differential temperature event.
                               bmDiffTempVHighClass 1.3.6.1.4.1.3052.18.2.12.14.4.1.7 displaystring read-write
Class for very high differential temperature event.
                               bmDiffTempHighValue 1.3.6.1.4.1.3052.18.2.12.14.4.1.8 integer32 read-write
High event threshold in degrees F or C, depending on scale setting.
                               bmDiffTempHighActions 1.3.6.1.4.1.3052.18.2.12.14.4.1.9 displaystring read-write
Actions for high differential temperature event.
                               bmDiffTempHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.4.1.10 integer32 read-write
Trap number for high differential temperature event.
                               bmDiffTempHighClass 1.3.6.1.4.1.3052.18.2.12.14.4.1.11 displaystring read-write
Class for high differential temperature event.
                               bmDiffTempNormalActions 1.3.6.1.4.1.3052.18.2.12.14.4.1.12 displaystring read-write
Actions for return to normal differential temperature event.
                               bmDiffTempNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.14.4.1.13 integer32 read-write
Trap number for return to normal differential temperature event.
                               bmDiffTempNormalClass 1.3.6.1.4.1.3052.18.2.12.14.4.1.14 displaystring read-write
Class for return to normal differential temperature event.
                               bmDiffTempSysrepEnable 1.3.6.1.4.1.3052.18.2.12.14.4.1.15 displaystring read-write
System reporting enable for differential temperature telemetry.
                               bmDiffTempSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.14.4.1.16 integer32 read-write
System reporting threshold for differential temperature telemetry.
                               bmDiffTempSysrepLimit 1.3.6.1.4.1.3052.18.2.12.14.4.1.17 integer32 read-write
System reporting limit for differential temperature telemetry.
                       batteryMonitorVoltageTable 1.3.6.1.4.1.3052.18.2.12.14.5 no-access
This table organizes battery monitor voltage attributes.
                           bmVoltageEntry 1.3.6.1.4.1.3052.18.2.12.14.5.1 no-access
Entry for battery monitor voltage config table.
                               bmVoltageIndex 1.3.6.1.4.1.3052.18.2.12.14.5.1.1 integer32 read-only
Which battery monitor in the battery monitor voltage config table.
                               bmVoltageEnable 1.3.6.1.4.1.3052.18.2.12.14.5.1.2 displaystring read-write
Enable/disable voltage event. This event is based on the total voltage output of the batteries in the string.
                               bmVoltageDeadband 1.3.6.1.4.1.3052.18.2.12.14.5.1.3 displaystring read-write
Deadband in volts. This is a floating point value.
                               bmVoltageVHighValue 1.3.6.1.4.1.3052.18.2.12.14.5.1.4 displaystring read-write
Very high event threshold, in volts. This is a floating point value.
                               bmVoltageVHighActions 1.3.6.1.4.1.3052.18.2.12.14.5.1.5 displaystring read-write
Actions for very high voltage event.
                               bmVoltageVHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.5.1.6 integer32 read-write
Trap number for very high voltage event.
                               bmVoltageVHighClass 1.3.6.1.4.1.3052.18.2.12.14.5.1.7 displaystring read-write
Class for very high voltage event.
                               bmVoltageHighValue 1.3.6.1.4.1.3052.18.2.12.14.5.1.8 displaystring read-write
High event threshold, in volts. This is a floating point value.
                               bmVoltageHighActions 1.3.6.1.4.1.3052.18.2.12.14.5.1.9 displaystring read-write
Actions for high voltage event.
                               bmVoltageHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.5.1.10 integer32 read-write
Trap number for high voltage event.
                               bmVoltageHighClass 1.3.6.1.4.1.3052.18.2.12.14.5.1.11 displaystring read-write
Class for high voltage event.
                               bmVoltageNormalActions 1.3.6.1.4.1.3052.18.2.12.14.5.1.12 displaystring read-write
Actions for return to normal voltage event.
                               bmVoltageNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.14.5.1.13 integer32 read-write
Trap number for return to normal voltage event.
                               bmVoltageNormalClass 1.3.6.1.4.1.3052.18.2.12.14.5.1.14 displaystring read-write
Class for return to normal voltage event.
                               bmVoltageLowValue 1.3.6.1.4.1.3052.18.2.12.14.5.1.15 displaystring read-write
Low event threshold, in volts. This is a floating point value.
                               bmVoltageLowActions 1.3.6.1.4.1.3052.18.2.12.14.5.1.16 displaystring read-write
Actions for low voltage event.
                               bmVoltageLowTrapNum 1.3.6.1.4.1.3052.18.2.12.14.5.1.17 integer32 read-write
Trap number for low voltage event.
                               bmVoltageLowClass 1.3.6.1.4.1.3052.18.2.12.14.5.1.18 displaystring read-write
Class for low voltage event.
                               bmVoltageVLowValue 1.3.6.1.4.1.3052.18.2.12.14.5.1.19 displaystring read-write
Very Low event threshold, in volts. This is a floating point value.
                               bmVoltageVLowActions 1.3.6.1.4.1.3052.18.2.12.14.5.1.20 displaystring read-write
Actions for very low voltage event.
                               bmVoltageVLowTrapNum 1.3.6.1.4.1.3052.18.2.12.14.5.1.21 integer32 read-write
Trap number for very low voltage event.
                               bmVoltageVLowClass 1.3.6.1.4.1.3052.18.2.12.14.5.1.22 displaystring read-write
Class for very low voltage event.
                               bmVoltageSysrepEnable 1.3.6.1.4.1.3052.18.2.12.14.5.1.23 displaystring read-write
System reporting enable for voltage telemetry.
                               bmVoltageSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.14.5.1.24 displaystring read-write
System reporting threshold for voltage telemetry. This is a floating point value.
                               bmVoltageSysrepLimit 1.3.6.1.4.1.3052.18.2.12.14.5.1.25 integer32 read-write
System reporting limit for voltage telemetry.
                       batteryMonitorDiffVoltTable 1.3.6.1.4.1.3052.18.2.12.14.6 no-access
This table organizes differential voltage battery monitor attributes.
                           bmDiffVoltEntry 1.3.6.1.4.1.3052.18.2.12.14.6.1 no-access
Entry for battery monitor differential voltage config table.
                               bmDiffVoltIndex 1.3.6.1.4.1.3052.18.2.12.14.6.1.1 integer32 read-only
Which battery monitor in the battery monitor differential voltage config table.
                               bmDiffVoltEnable 1.3.6.1.4.1.3052.18.2.12.14.6.1.2 displaystring read-write
Enable/disable differential voltage event. This event is based on the differential between the highest and lowest jar voltages within the string.
                               bmDiffVoltDeadband 1.3.6.1.4.1.3052.18.2.12.14.6.1.3 displaystring read-write
Deadband in volts.
                               bmDiffVoltVHighValue 1.3.6.1.4.1.3052.18.2.12.14.6.1.4 displaystring read-write
Very high event threshold in volts. This is a floating point value.
                               bmDiffVoltVHighActions 1.3.6.1.4.1.3052.18.2.12.14.6.1.5 displaystring read-write
Actions for very high differential voltage event.
                               bmDiffVoltVHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.6.1.6 integer32 read-write
Trap number for very high differential voltage event.
                               bmDiffVoltVHighClass 1.3.6.1.4.1.3052.18.2.12.14.6.1.7 displaystring read-write
Class for very high differential voltage event.
                               bmDiffVoltHighValue 1.3.6.1.4.1.3052.18.2.12.14.6.1.8 displaystring read-write
High event threshold in volts. This is a floating point value.
                               bmDiffVoltHighActions 1.3.6.1.4.1.3052.18.2.12.14.6.1.9 displaystring read-write
Actions for high differential voltage event.
                               bmDiffVoltHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.6.1.10 integer32 read-write
Trap number for high differential voltage event.
                               bmDiffVoltHighClass 1.3.6.1.4.1.3052.18.2.12.14.6.1.11 displaystring read-write
Class for high differential voltage event.
                               bmDiffVoltNormalActions 1.3.6.1.4.1.3052.18.2.12.14.6.1.12 displaystring read-write
Actions for return to normal differential voltage event.
                               bmDiffVoltNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.14.6.1.13 integer32 read-write
Trap number for return to normal differential voltage event.
                               bmDiffVoltNormalClass 1.3.6.1.4.1.3052.18.2.12.14.6.1.14 displaystring read-write
Class for return to normal differential voltage event.
                               bmDiffVoltSysrepEnable 1.3.6.1.4.1.3052.18.2.12.14.6.1.15 displaystring read-write
System reporting enable for differential voltage telemetry.
                               bmDiffVoltSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.14.6.1.16 displaystring read-write
System reporting threshold for differential voltage telemetry.
                               bmDiffVoltSysrepLimit 1.3.6.1.4.1.3052.18.2.12.14.6.1.17 integer32 read-write
System reporting limit for differential voltage telemetry.
                       batteryMonitorChargingCurrentTable 1.3.6.1.4.1.3052.18.2.12.14.7 no-access
This table organizes battery monitor charging current attributes.
                           bmChargingCurrentEntry 1.3.6.1.4.1.3052.18.2.12.14.7.1 no-access
Entry for battery monitor differential charging current config table.
                               bmChargingCurrentIndex 1.3.6.1.4.1.3052.18.2.12.14.7.1.1 integer32 read-only
Which battery monitor in the battery monitor charging current config table.
                               bmChargingCurrentEnable 1.3.6.1.4.1.3052.18.2.12.14.7.1.2 displaystring read-write
Enable/disable charging current event. This event is based on positive current flow (i.e. current flowing into the battery string).
                               bmChargingCurrentDeadband 1.3.6.1.4.1.3052.18.2.12.14.7.1.3 displaystring read-write
Deadband in amperes. This is a floating point value.
                               bmChargingCurrentVHighValue 1.3.6.1.4.1.3052.18.2.12.14.7.1.4 displaystring read-write
Very high event threshold, in volts. This is a floating point value.
                               bmChargingCurrentVHighActions 1.3.6.1.4.1.3052.18.2.12.14.7.1.5 displaystring read-write
Actions for very high charging current event.
                               bmChargingCurrentVHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.7.1.6 integer32 read-write
Trap number for very high charging current event.
                               bmChargingCurrentVHighClass 1.3.6.1.4.1.3052.18.2.12.14.7.1.7 displaystring read-write
Class for very high charging current event.
                               bmChargingCurrentHighValue 1.3.6.1.4.1.3052.18.2.12.14.7.1.8 displaystring read-write
High event threshold, in volts. This is a floating point value.
                               bmChargingCurrentHighActions 1.3.6.1.4.1.3052.18.2.12.14.7.1.9 displaystring read-write
Actions for high charging current event.
                               bmChargingCurrentHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.7.1.10 integer32 read-write
Trap number for high charging current event.
                               bmChargingCurrentHighClass 1.3.6.1.4.1.3052.18.2.12.14.7.1.11 displaystring read-write
Class for high charging current event.
                               bmChargingCurrentNormalActions 1.3.6.1.4.1.3052.18.2.12.14.7.1.12 displaystring read-write
Actions for return to normal charging current event.
                               bmChargingCurrentNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.14.7.1.13 integer32 read-write
Trap number for return to normal charging current event.
                               bmChargingCurrentNormalClass 1.3.6.1.4.1.3052.18.2.12.14.7.1.14 displaystring read-write
Class for return to normal charging current event.
                               bmChargingCurrentSysrepEnable 1.3.6.1.4.1.3052.18.2.12.14.7.1.15 displaystring read-write
System reporting enable for charging current telemetry.
                               bmChargingCurrentSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.14.7.1.16 displaystring read-write
System reporting threshold for charging current telemetry. This is a floating point value.
                               bmChargingCurrentSysrepLimit 1.3.6.1.4.1.3052.18.2.12.14.7.1.17 integer32 read-write
System reporting limit for charging current telemetry.
                       batteryMonitorDischargingCurrentTable 1.3.6.1.4.1.3052.18.2.12.14.8 no-access
This table organizes battery monitor discharging current attributes.
                           bmDischargingCurrentEntry 1.3.6.1.4.1.3052.18.2.12.14.8.1 no-access
Entry for battery monitor differential discharging current config table.
                               bmDischargingCurrentIndex 1.3.6.1.4.1.3052.18.2.12.14.8.1.1 integer32 read-only
Which battery monitor in the battery monitor discharging current config table.
                               bmDischargingCurrentEnable 1.3.6.1.4.1.3052.18.2.12.14.8.1.2 displaystring read-write
Enable/disable discharging current event. This event is based on positive current flow (i.e. current flowing into the battery string).
                               bmDischargingCurrentDeadband 1.3.6.1.4.1.3052.18.2.12.14.8.1.3 displaystring read-write
Deadband in amperes. This is a floating point value.
                               bmDischargingCurrentVHighValue 1.3.6.1.4.1.3052.18.2.12.14.8.1.4 displaystring read-write
Very high event threshold, in volts. This is a floating point value.
                               bmDischargingCurrentVHighActions 1.3.6.1.4.1.3052.18.2.12.14.8.1.5 displaystring read-write
Actions for very high discharging current event.
                               bmDischargingCurrentVHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.8.1.6 integer32 read-write
Trap number for very high discharging current event.
                               bmDischargingCurrentVHighClass 1.3.6.1.4.1.3052.18.2.12.14.8.1.7 displaystring read-write
Class for very high discharging current event.
                               bmDischargingCurrentHighValue 1.3.6.1.4.1.3052.18.2.12.14.8.1.8 displaystring read-write
High event threshold, in volts. This is a floating point value.
                               bmDischargingCurrentHighActions 1.3.6.1.4.1.3052.18.2.12.14.8.1.9 displaystring read-write
Actions for high discharging current event.
                               bmDischargingCurrentHighTrapNum 1.3.6.1.4.1.3052.18.2.12.14.8.1.10 integer32 read-write
Trap number for high discharging current event.
                               bmDischargingCurrentHighClass 1.3.6.1.4.1.3052.18.2.12.14.8.1.11 displaystring read-write
Class for high discharging current event.
                               bmDischargingCurrentNormalActions 1.3.6.1.4.1.3052.18.2.12.14.8.1.12 displaystring read-write
Actions for return to normal discharging current event.
                               bmDischargingCurrentNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.14.8.1.13 integer32 read-write
Trap number for return to normal discharging current event.
                               bmDischargingCurrentNormalClass 1.3.6.1.4.1.3052.18.2.12.14.8.1.14 displaystring read-write
Class for return to normal discharging current event.
                               bmDischargingCurrentSysrepEnable 1.3.6.1.4.1.3052.18.2.12.14.8.1.15 displaystring read-write
System reporting enable for discharging current telemetry.
                               bmDischargingCurrentSysrepThreshold 1.3.6.1.4.1.3052.18.2.12.14.8.1.16 displaystring read-write
System reporting threshold for discharging current telemetry. This is a floating point value.
                               bmDischargingCurrentSysrepLimit 1.3.6.1.4.1.3052.18.2.12.14.8.1.17 integer32 read-write
System reporting limit for discharging current telemetry.
                       batteryMonitorChargeLevelTable 1.3.6.1.4.1.3052.18.2.12.14.9 no-access
This table organizes battery monitor charge level attributes.
                           bmChargeLevelEntry 1.3.6.1.4.1.3052.18.2.12.14.9.1 no-access
Entry for battery monitor charge level config table.
                               bmChargeLevelIndex 1.3.6.1.4.1.3052.18.2.12.14.9.1.1 integer32 read-only
Which battery monitor in the battery monitor charge level config table.
                               bmChargeLevelEnable 1.3.6.1.4.1.3052.18.2.12.14.9.1.2 displaystring read-write
Enable/disable charge level event.
                               bmChargeLevelNormalActions 1.3.6.1.4.1.3052.18.2.12.14.9.1.3 displaystring read-write
Actions for return to normal charge level event.
                               bmChargeLevelNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.14.9.1.4 integer32 read-write
Trap number for return to normal charge level event.
                               bmChargeLevelNormalClass 1.3.6.1.4.1.3052.18.2.12.14.9.1.5 displaystring read-write
Class for return to normal charge level event.
                               bmChargeLevelLowActions 1.3.6.1.4.1.3052.18.2.12.14.9.1.6 displaystring read-write
Actions for low charge level event.
                               bmChargeLevelLowTrapNum 1.3.6.1.4.1.3052.18.2.12.14.9.1.7 integer32 read-write
Trap number for low charge level event.
                               bmChargeLevelLowClass 1.3.6.1.4.1.3052.18.2.12.14.9.1.8 displaystring read-write
Class for low charge level event.
                               bmChargeLevelVLowActions 1.3.6.1.4.1.3052.18.2.12.14.9.1.9 displaystring read-write
Actions for very low charge level event.
                               bmChargeLevelVLowTrapNum 1.3.6.1.4.1.3052.18.2.12.14.9.1.10 integer32 read-write
Trap number for very low charge level event.
                               bmChargeLevelVLowClass 1.3.6.1.4.1.3052.18.2.12.14.9.1.11 displaystring read-write
Class for very low charge level event.
                               bmChargeLevelSysrepEnable 1.3.6.1.4.1.3052.18.2.12.14.9.1.12 displaystring read-write
System reporting enable for charge level telemetry.
                       batteryMonitorJarHealthTable 1.3.6.1.4.1.3052.18.2.12.14.10 no-access
This table organizes battery monitor jar health attributes.
                             bmJarHealthEntry 1.3.6.1.4.1.3052.18.2.12.14.10.1 no-access
Entry for battery monitor jar health config table.
                                 bmJarHealthIndex 1.3.6.1.4.1.3052.18.2.12.14.10.1.1 integer32 read-only
Which battery monitor in the battery monitor jar health config table.
                                 bmJarHealthEnable 1.3.6.1.4.1.3052.18.2.12.14.10.1.2 displaystring read-write
Enable/disable jar health event.
                                 bmJarHealthNormalActions 1.3.6.1.4.1.3052.18.2.12.14.10.1.3 displaystring read-write
Actions for return to normal jar health event.
                                 bmJarHealthNormalTrapNum 1.3.6.1.4.1.3052.18.2.12.14.10.1.4 integer32 read-write
Trap number for return to normal jar health event.
                                 bmJarHealthNormalClass 1.3.6.1.4.1.3052.18.2.12.14.10.1.5 displaystring read-write
Class for return to normal jar health event.
                                 bmJarHealthLowActions 1.3.6.1.4.1.3052.18.2.12.14.10.1.6 displaystring read-write
Actions for low jar health event.
                                 bmJarHealthLowTrapNum 1.3.6.1.4.1.3052.18.2.12.14.10.1.7 integer32 read-write
Trap number for low jar health event.
                                 bmJarHealthLowClass 1.3.6.1.4.1.3052.18.2.12.14.10.1.8 displaystring read-write
Class for low jar health event.
                                 bmJarHealthVLowActions 1.3.6.1.4.1.3052.18.2.12.14.10.1.9 displaystring read-write
Actions for very low jar health event.
                                 bmJarHealthVLowTrapNum 1.3.6.1.4.1.3052.18.2.12.14.10.1.10 integer32 read-write
Trap number for very low jar health event.
                                 bmJarHealthVLowClass 1.3.6.1.4.1.3052.18.2.12.14.10.1.11 displaystring read-write
Class for very low jar health event.
                                 bmJarHealthSysrepEnable 1.3.6.1.4.1.3052.18.2.12.14.10.1.12 displaystring read-write
System reporting enable for jar health telemetry.
                 evLocation 1.3.6.1.4.1.3052.18.2.12.15
                       evLocationEnable 1.3.6.1.4.1.3052.18.2.12.15.1 displaystring read-write
Enable/disable location event. This event is triggered after the unit boots and gets a valid location fix from the GPS, or a timeout expires.
                       evLocationTimeout 1.3.6.1.4.1.3052.18.2.12.15.2 integer32 read-write
How long the unit waits for valid location fix before giving up and generating location event anyhow.
                       evLocationActions 1.3.6.1.4.1.3052.18.2.12.15.3 displaystring read-write
Actions for location event.
                       evLocationMsgSuccess 1.3.6.1.4.1.3052.18.2.12.15.4 displaystring read-write
Event message string that is used when location is successfully detected.
                       evLocationMsgFail 1.3.6.1.4.1.3052.18.2.12.15.5 displaystring read-write
Event message string that is used when location is cannot be detected.
                       evLocationIncludeLocation 1.3.6.1.4.1.3052.18.2.12.15.6 displaystring read-write
Enable/disable appending the location information to the event message.
                       evLocationTrapnum 1.3.6.1.4.1.3052.18.2.12.15.7 integer32 read-write
Trap number for the location event.
                       evLocationClass 1.3.6.1.4.1.3052.18.2.12.15.8 displaystring read-write
Class for the location event.
                 evReset 1.3.6.1.4.1.3052.18.2.12.16
                       evResetEnable 1.3.6.1.4.1.3052.18.2.12.16.1 displaystring read-write
Enable/disable reset event. This event is triggered when the unit finishes booting.
                       evResetDelay 1.3.6.1.4.1.3052.18.2.12.16.2 integer32 read-write
Number of seconds to wait after unit finishes booting before triggering the reset event.
                       evResetActions 1.3.6.1.4.1.3052.18.2.12.16.3 displaystring read-write
Actions for reset event.
                       evResetMessage 1.3.6.1.4.1.3052.18.2.12.16.4 displaystring read-write
Message for reset event.
                       evResetTrapnum 1.3.6.1.4.1.3052.18.2.12.16.5 integer32 read-write
Trap number for reset event.
                       evResetClass 1.3.6.1.4.1.3052.18.2.12.16.6 displaystring read-write
Class (severity) for reset event.
                 evSleep 1.3.6.1.4.1.3052.18.2.12.17
                       evSleepEnable 1.3.6.1.4.1.3052.18.2.12.17.1 displaystring read-write
Enable/disable sleep event. This event is triggered when the unit is imminently going to sleep.
                       evSleepActions 1.3.6.1.4.1.3052.18.2.12.17.3 displaystring read-write
Actions for sleep event.
                       evSleepMessage 1.3.6.1.4.1.3052.18.2.12.17.4 displaystring read-write
Message for sleep event.
                       evSleepTrapnum 1.3.6.1.4.1.3052.18.2.12.17.5 integer32 read-write
Trap number for sleep event.
                       evSleepClass 1.3.6.1.4.1.3052.18.2.12.17.6 displaystring read-write
Class (severity) for sleep event.
                 evGlobal 1.3.6.1.4.1.3052.18.2.12.18
                       evGlobalActions 1.3.6.1.4.1.3052.18.2.12.18.2 displaystring read-write
Global event actions.
                       evGlobalTrapnum 1.3.6.1.4.1.3052.18.2.12.18.3 integer32 read-write
Global trap number.
                 accessControl 1.3.6.1.4.1.3052.18.2.12.21
                       acActions 1.3.6.1.4.1.3052.18.2.12.21.2 displaystring read-write
Actions for the access control event.
                       acTrapnum 1.3.6.1.4.1.3052.18.2.12.21.3 integer32 read-write
Trap number for the access control event.
                       acClass 1.3.6.1.4.1.3052.18.2.12.21.4 displaystring read-write
Class (severity) for the access control event.
                       accessControlDeviceTable 1.3.6.1.4.1.3052.18.2.12.21.10 no-access
Table of access control devices for Access Control Device Management.
                             accessControlDeviceEntry 1.3.6.1.4.1.3052.18.2.12.21.10.1 no-access
Entry for table of access control devices for Access Control Device Management.
                                 acdIndex 1.3.6.1.4.1.3052.18.2.12.21.10.1.1 integer32 read-only
Index for table of access control devices for Access Control Device Management.
                                 acdEnable 1.3.6.1.4.1.3052.18.2.12.21.10.1.2 displaystring read-write
Enable management for this access control device.
                                 acdName 1.3.6.1.4.1.3052.18.2.12.21.10.1.3 displaystring read-write
The name of the access control device for informational purpose only.
                                 acdReader 1.3.6.1.4.1.3052.18.2.12.21.10.1.4 displaystring read-write
The kind of access control device.
                                 acdWiegandES 1.3.6.1.4.1.3052.18.2.12.21.10.1.6 integer32 read-write
Index of the Wiegand interface hardware instance allocated as the access control device.
                                 acdRelayType 1.3.6.1.4.1.3052.18.2.12.21.10.1.7 displaystring read-write
Type of relay which activates the door strike.
                                 acdRelayES 1.3.6.1.4.1.3052.18.2.12.21.10.1.8 integer32 read-write
Which relay EventSensor is connected to the door strike.
                                 acdRelayPoint 1.3.6.1.4.1.3052.18.2.12.21.10.1.9 integer32 read-write
Which relay on the relay EventSensor is connected to the door strike.
                                 acdOpenTime 1.3.6.1.4.1.3052.18.2.12.21.10.1.10 integer32 read-write
                                 acdUserGroup 1.3.6.1.4.1.3052.18.2.12.21.10.1.11 integer32 read-write
User group to which this access control device applies.
                       accessControlUserTable 1.3.6.1.4.1.3052.18.2.12.21.11 no-access
Table of access control users for Access Control Device Management.
                             accessControlUserEntry 1.3.6.1.4.1.3052.18.2.12.21.11.1 no-access
Entry for table of access control users for Access Control Device Management.
                                 acuIndexUserGroup 1.3.6.1.4.1.3052.18.2.12.21.11.1.1 integer32 read-only
Index for table of access control devices for Access Control Device Management which corresponds to the user group containing the user.
                                 acuIndexUser 1.3.6.1.4.1.3052.18.2.12.21.11.1.2 integer32 read-only
Index for table of access control devices for Access Control Device Management which corresponds to the user within the user group.
                                 acuEnable 1.3.6.1.4.1.3052.18.2.12.21.11.1.3 displaystring read-write
Enable this access control user.
                                 acuName 1.3.6.1.4.1.3052.18.2.12.21.11.1.4 displaystring read-write
Name for this access control user.
                                 acuSn 1.3.6.1.4.1.3052.18.2.12.21.11.1.5 displaystring read-write
Serial number of the card associated with the user.
                                 acuSunBegin 1.3.6.1.4.1.3052.18.2.12.21.11.1.6 displaystring read-write
Time of day (HH:MM) on Sundays when this user should be granted access.
                                 acuSunEnd 1.3.6.1.4.1.3052.18.2.12.21.11.1.7 displaystring read-write
Time of day (HH:MM) on Sundays when this user should be forbidden access.
                                 acuMonBegin 1.3.6.1.4.1.3052.18.2.12.21.11.1.8 displaystring read-write
Time of day (HH:MM) on Mondays when this user should be granted access.
                                 acuMonEnd 1.3.6.1.4.1.3052.18.2.12.21.11.1.9 displaystring read-write
Time of day (HH:MM) on Mondays when this user should be forbidden access.
                                 acuTueBegin 1.3.6.1.4.1.3052.18.2.12.21.11.1.10 displaystring read-write
Time of day (HH:MM) on Tuesdays when this user should be granted access.
                                 acuTueEnd 1.3.6.1.4.1.3052.18.2.12.21.11.1.11 displaystring read-write
Time of day (HH:MM) on Tuesdays when this user should be forbidden access.
                                 acuWedBegin 1.3.6.1.4.1.3052.18.2.12.21.11.1.12 displaystring read-write
Time of day (HH:MM) on Wednesdays when this user should be granted access.
                                 acuWedEnd 1.3.6.1.4.1.3052.18.2.12.21.11.1.13 displaystring read-write
Time of day (HH:MM) on Wednesdays when this user should be forbidden access.
                                 acuThuBegin 1.3.6.1.4.1.3052.18.2.12.21.11.1.14 displaystring read-write
Time of day (HH:MM) on Thursdays when this user should be granted access.
                                 acuThuEnd 1.3.6.1.4.1.3052.18.2.12.21.11.1.15 displaystring read-write
Time of day (HH:MM) on Thursdays when this user should be forbidden access.
                                 acuFriBegin 1.3.6.1.4.1.3052.18.2.12.21.11.1.16 displaystring read-write
Time of day (HH:MM) on Fridays when this user should be granted access.
                                 acuFriEnd 1.3.6.1.4.1.3052.18.2.12.21.11.1.17 displaystring read-write
Time of day (HH:MM) on Fridays when this user should be forbidden access.
                                 acuSatBegin 1.3.6.1.4.1.3052.18.2.12.21.11.1.18 displaystring read-write
Time of day (HH:MM) on Saturdays when this user should be granted access.
                                 acuSatEnd 1.3.6.1.4.1.3052.18.2.12.21.11.1.19 displaystring read-write
Time of day (HH:MM) on Saturdays when this user should be forbidden access.
           action 1.3.6.1.4.1.3052.18.2.14
                 actionSched 1.3.6.1.4.1.3052.18.2.14.3
                     actionSchedEnable 1.3.6.1.4.1.3052.18.2.14.3.1 displaystring read-write
ON/OFF enable action schedule
                     actionSchedBegin 1.3.6.1.4.1.3052.18.2.14.3.2 displaystring read-write
action schedule begin time (HH:MM)
                     actionSchedEnd 1.3.6.1.4.1.3052.18.2.14.3.3 displaystring read-write
action schedule end time (HH:MM)
                     actionSchedWeekdaysOnly 1.3.6.1.4.1.3052.18.2.14.3.4 displaystring read-write
ON/OFF whether the action schedule applies to weekdays only (ON) or all days (OFF)
                 actionAsentria 1.3.6.1.4.1.3052.18.2.14.4
                     actionAsentriaRequireAck 1.3.6.1.4.1.3052.18.2.14.4.1 displaystring read-write
ON/OFF Asentria action requires an ack from the receiver
                     actionAsentriaVersion 1.3.6.1.4.1.3052.18.2.14.4.2 displaystring read-write
version 1.0 or 1.1
                     actionAsentriaTCPPort 1.3.6.1.4.1.3052.18.2.14.4.3 integer32 read-write
TCP port used for TCP-based Asentria alarms
                 actionHostTable 1.3.6.1.4.1.3052.18.2.14.6 no-access
Table of network hosts to use for network-based actions
                     actionHostEntry 1.3.6.1.4.1.3052.18.2.14.6.1 no-access
Entry for table of network hosts to use for network-based actions
                         actionHostIndex 1.3.6.1.4.1.3052.18.2.14.6.1.1 integer32 read-only
Index for table of network hosts to use for network-based actions
                         actionHost 1.3.6.1.4.1.3052.18.2.14.6.1.2 displaystring read-write
Hostname/IP address used as destination for network-based action (e.g., trap)
                 actionEmailTable 1.3.6.1.4.1.3052.18.2.14.7 no-access
Table of email addresses to use for email actions
                     actionEmailEntry 1.3.6.1.4.1.3052.18.2.14.7.1 no-access
Entry for table of email addresses to use for email actions
                         actionEmailIndex 1.3.6.1.4.1.3052.18.2.14.7.1.1 integer32 read-only
Index for table of email addresses to use for email actions
                         actionEmail 1.3.6.1.4.1.3052.18.2.14.7.1.2 displaystring read-write
email address
                 actionParseError 1.3.6.1.4.1.3052.18.2.14.8 displaystring read-only
When a user attempts to configure an invalid action setting/ object, this object says why it was invalid.
           sys 1.3.6.1.4.1.3052.18.2.16
                 sysTime 1.3.6.1.4.1.3052.18.2.16.1
                     sysTimeAutoDST 1.3.6.1.4.1.3052.18.2.16.1.1 displaystring read-write
ON/OFF automatically adjust for Daylight Savings Time
                     sysTimeGMTOffset 1.3.6.1.4.1.3052.18.2.16.1.2 integer32 read-write
Absolute value of offset (hours) from GMT of the timezone
                     sysTimeGMTDirection 1.3.6.1.4.1.3052.18.2.16.1.3 displaystring read-write
Direction (AHEAD/BEHIND) of timezone relative to GMT
                     sysTimeNet 1.3.6.1.4.1.3052.18.2.16.1.4
                         sysTimeNetEnable 1.3.6.1.4.1.3052.18.2.16.1.4.1 displaystring read-write
Network time mode
                         sysTimeNetHostTable 1.3.6.1.4.1.3052.18.2.16.1.4.2 no-access
Table of hosts to use for network time services
                             sysTimeNetHostEntry 1.3.6.1.4.1.3052.18.2.16.1.4.2.1 no-access
Entry for table of hosts to use for network time services
                                 sysTimeNetHostIndex 1.3.6.1.4.1.3052.18.2.16.1.4.2.1.1 integer32 read-only
Index for table of hosts to use for network time services
                                 sysTimeNetHost 1.3.6.1.4.1.3052.18.2.16.1.4.2.1.2 displaystring read-write
host to use for network time services
                 sysPT 1.3.6.1.4.1.3052.18.2.16.2
                     sysPTTimeout 1.3.6.1.4.1.3052.18.2.16.2.1 integer32 read-write
Timeout (minutes) of inactivity after which a pass-through session is terminated (0 means it never terminates)
                     sysPTEndPause 1.3.6.1.4.1.3052.18.2.16.2.2 integer32 read-write
number of 16ths of a second between escape characters received on pass-through origin IO handle that are reuired for the escape characters to register as pass-through escape characters in the pass-through escape sequence. Set to 0 to make the escape character register as part of the pass- through escape sequence without requiring a pause.
                     sysPTJoinable 1.3.6.1.4.1.3052.18.2.16.2.3 displaystring read-write
Enable joinable pass-through sessions.
                 sysMTU 1.3.6.1.4.1.3052.18.2.16.3 integer32 read-write
Maximum transfer unit for ethernet interfaces
                 sysAnswerString 1.3.6.1.4.1.3052.18.2.16.4 displaystring read-write
String displayed upon login
                 sysEventFileID 1.3.6.1.4.1.3052.18.2.16.6 displaystring read-write
ID string for events file
                 sysEscapeCharacter 1.3.6.1.4.1.3052.18.2.16.7 integer32 read-write
Decimal ASCII code of the system escape character
                 sysTimeStamp 1.3.6.1.4.1.3052.18.2.16.8
                     sysTimeStampTimeFormat 1.3.6.1.4.1.3052.18.2.16.8.1 displaystring read-write
Format of time stamp: HH:MM,HH:MM:SS,BLANK
                     sysTimeStampDateFormat 1.3.6.1.4.1.3052.18.2.16.8.2 displaystring read-write
Format of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANK
                     sysTimeStampSpaceAfter 1.3.6.1.4.1.3052.18.2.16.8.3 displaystring read-write
ON/OFF Inlude a space after timestamp
                 sysLog 1.3.6.1.4.1.3052.18.2.16.9
                     sysLogMode 1.3.6.1.4.1.3052.18.2.16.9.1 displaystring read-write
Syslog mode: disabled, emit UDP (REMOTE), save in a rotating file set (FILE), or emit on a listening socket (SERVER)
                     sysLoghost 1.3.6.1.4.1.3052.18.2.16.9.2 displaystring read-write
Syslog host: destination machine when syslog mode is REMOTE
                     sysLogFilter 1.3.6.1.4.1.3052.18.2.16.9.3 displaystring read-write
String describing what functions place data in the syslog
                     sysLogFileSize 1.3.6.1.4.1.3052.18.2.16.9.4 integer32 read-write
Size (in KB) of syslog files (when syslog mode is SERVER or FILE)
                     sysLogFileCount 1.3.6.1.4.1.3052.18.2.16.9.5 integer32 read-write
Number of files in syslog file set (when syslog mode is SERVER or FILE)
                     sysLogListenPort 1.3.6.1.4.1.3052.18.2.16.9.6 integer32 read-write
TCP port on which the unit listens for a connection on which syslog data is dumped (when syslog mode is SERVER)
                 sysCRDB 1.3.6.1.4.1.3052.18.2.16.10
                       sysCRDBCapacity 1.3.6.1.4.1.3052.18.2.16.10.1 integer32 read-only
Capacity of Call Record Database (in KB)
                       sysCRDBPercentFull 1.3.6.1.4.1.3052.18.2.16.10.2 integer32 read-only
Percent of the CRDB used
                       sysCRDBFileIDTable 1.3.6.1.4.1.3052.18.2.16.10.3 no-access
Table of CRDB file IDs
                           sysCRDBFileIDEntry 1.3.6.1.4.1.3052.18.2.16.10.3.1 no-access
Entry for table of CRDB file IDs
                               sysCRDBFileIDIndex 1.3.6.1.4.1.3052.18.2.16.10.3.1.1 integer32 read-only
Index for table of CRDB file IDs
                               sysCRDBFileID 1.3.6.1.4.1.3052.18.2.16.10.3.1.2 displaystring read-write
ID of CRDB file for this port-associated file x
                       sysCRDBFileEnforceMinTable 1.3.6.1.4.1.3052.18.2.16.10.4 no-access
Table of CRDB file minimum size enforcement settings
                           sysCRDBFileEnforceMinEntry 1.3.6.1.4.1.3052.18.2.16.10.4.1 no-access
Entry for table of CRDB file minimum size enforcement settings
                               sysCRDBFileEnforceMinIndex 1.3.6.1.4.1.3052.18.2.16.10.4.1.1 integer32 read-only
Index for table of CRDB file minimum size enforcement settings
                               sysCRDBFileEnforceMin 1.3.6.1.4.1.3052.18.2.16.10.4.1.2 displaystring read-write
ON/OFF: enforce minimum size for this CRDB file x
                 sysCharMask 1.3.6.1.4.1.3052.18.2.16.11 octet string read-write
Character mask used for ignoring certain characters on serial ports when assembling data records (when port mode is ASCII)
                 sysPrompt 1.3.6.1.4.1.3052.18.2.16.12 displaystring read-write
Prompt to use in a commnand session
                 sysBootStatus 1.3.6.1.4.1.3052.18.2.16.13 displaystring read-only
String describing the boot status of the unit (Booted OK/ still booting
                 sysLoc 1.3.6.1.4.1.3052.18.2.16.14
                       sysLocLatitude 1.3.6.1.4.1.3052.18.2.16.14.1 displaystring read-write
Latitude portion of geographic coordinates as string
                       sysLocLongitude 1.3.6.1.4.1.3052.18.2.16.14.2 displaystring read-write
Longitude portion of geographic coordinates as string
                       sysLocXOffset 1.3.6.1.4.1.3052.18.2.16.14.3 displaystring read-write
X-offset portion of geographic coordinates as string
                       sysLocYOffset 1.3.6.1.4.1.3052.18.2.16.14.4 displaystring read-write
Y offset portion of geographic coordinates as string
                       sysLocAngle 1.3.6.1.4.1.3052.18.2.16.14.5 displaystring read-write
Angle portion of geographic coordinates as string
                       sysLocAltitude 1.3.6.1.4.1.3052.18.2.16.14.6 displaystring read-write
Altitude as string
                 sysSleep 1.3.6.1.4.1.3052.18.2.16.16
                       sysSleepEnable 1.3.6.1.4.1.3052.18.2.16.16.1 displaystring read-write
Enables/disables sleep mode. The unit will go into sleep mode only if this is set to ON.
                       sysSleepSleep 1.3.6.1.4.1.3052.18.2.16.16.2
                           sysSleepForceSleep 1.3.6.1.4.1.3052.18.2.16.16.2.1 displaystring read-write
Write any value to this object to put the unit into sleep mode immediately (provided sleep mode is enabled)
                           sysSleepSleepTimer 1.3.6.1.4.1.3052.18.2.16.16.2.2 integer32 read-write
How long, in minutes, before the unit will go into sleep mode, measured from the time it is fully started up, or from the time generator/shore power is lost. A command could cause the unit to sleep sooner.
                       sysSleepWake 1.3.6.1.4.1.3052.18.2.16.16.3
                           sysSleepWakeTimerNormal 1.3.6.1.4.1.3052.18.2.16.16.3.1 integer32 read-write
How long, in minutes, the unit will sleep once it goes into sleep mode, unless something else, such as generator/shore power restoration or movement, causes wake-up. This timer is used if the unit is not in motion when it goes to sleep.
                           sysSleepWakeTimerMotion 1.3.6.1.4.1.3052.18.2.16.16.3.2 integer32 read-write
How long, in minutes, the unit will sleep once it goes into sleep mode, unless something else, such as generator/shore power restoration, causes wake-up. This timer is used if the unit goes to sleep while it is in motion, as determined by the GPS receiver.
                           sysSleepWakeMotionEnable 1.3.6.1.4.1.3052.18.2.16.16.3.3 displaystring read-write
Enables/disables waking on detected motion.
                           sysSleepWakeScheduledEnable 1.3.6.1.4.1.3052.18.2.16.16.3.4 displaystring read-write
Enabled/disables waking at a specified time of day.
                           sysSleepWakeScheduledTimeOfDay 1.3.6.1.4.1.3052.18.2.16.16.3.5 displaystring read-write
Specifies what time of day to wake up. Value is in HH:MM format.
                       sysSleepPowerDetectCC 1.3.6.1.4.1.3052.18.2.16.16.4
                           sysSleepPowerDetectCCEnable 1.3.6.1.4.1.3052.18.2.16.16.4.1 displaystring read-write
Enables/disables detection of generator/shore power via contact closure 1.
                           sysSleepPowerDetectCCPowerOnState 1.3.6.1.4.1.3052.18.2.16.16.4.2 displaystring read-write
Sets the state (open or closed) that represents generator/shore power being present.
                           sysSleepPowerDetectCCThreshold 1.3.6.1.4.1.3052.18.2.16.16.4.3 integer32 read-write
Sets the time period, in seconds, for how long the CC must be in a given state for generator/shore power to be considered present or not.
                 sysFileTransfer 1.3.6.1.4.1.3052.18.2.16.17
                       sysFileTransferStatus 1.3.6.1.4.1.3052.18.2.16.17.1 displaystring read-write
Start/cancel file transfer, or check transfer status. To start, set this object to 'start'. To cancel, set this object to 'cancel'. To check status, get the object
                       sysFileTransferURL 1.3.6.1.4.1.3052.18.2.16.17.2 displaystring read-write
URL (describing protocol, host, directory, and file) on which file transfer function operates.
                       sysFileTransferUsername 1.3.6.1.4.1.3052.18.2.16.17.3 displaystring read-write
Username for user account at the resource specified by sysFileTransferURL.
                       sysFileTransferPassword 1.3.6.1.4.1.3052.18.2.16.17.4 displaystring read-write
Password for user account at the resource specified by sysFileTransferURL.
                 sysUpdate 1.3.6.1.4.1.3052.18.2.16.18
                       sysUpdateStatus 1.3.6.1.4.1.3052.18.2.16.18.1 displaystring read-only
Check time/result of last update attempt.
           auditLog 1.3.6.1.4.1.3052.18.2.17
                 auditLogEnable 1.3.6.1.4.1.3052.18.2.17.1 displaystring read-write
ON/OFF enable audit log
                 auditLogStoreResets 1.3.6.1.4.1.3052.18.2.17.2 displaystring read-write
ON/OFF audit log stores when the unit resets
                 auditLogStoreCommands 1.3.6.1.4.1.3052.18.2.17.3 displaystring read-write
ON/OFF audit log stores commands entered in a command session
                 auditLogStoreOutputs 1.3.6.1.4.1.3052.18.2.17.4 displaystring read-write
ON/OFF audit log stores output (relay output and power output) activity
                 auditLogStoreAlarmActions 1.3.6.1.4.1.3052.18.2.17.5 displaystring read-write
ON/OFF audit log stores action delivery activity
                 auditLogStorePwdFailures 1.3.6.1.4.1.3052.18.2.17.6 displaystring read-write
ON/OFF audit log stores when user was denied login
                 auditLogStoreLogins 1.3.6.1.4.1.3052.18.2.17.7 displaystring read-write
ON/OFF audit log stores when a user was allowed login
                 auditLogStoreSHSK 1.3.6.1.4.1.3052.18.2.17.8 displaystring read-write
ON/OFF audit log stores serial handshaking status (regardless of serial handshaking event)
                 auditLogStorePassthrough 1.3.6.1.4.1.3052.18.2.17.9 displaystring read-write
ON/OFF audit log stores pass-through activity
                 auditLogStoreInactivity 1.3.6.1.4.1.3052.18.2.17.10 displaystring read-write
ON/OFF audit log stores when sessions expire due to inactivity
                 auditLogStorePolling 1.3.6.1.4.1.3052.18.2.17.11 displaystring read-write
ON/OFF audit log stores CRDB polling activity
                 auditLogMaxSize 1.3.6.1.4.1.3052.18.2.17.12 integer32 read-write
Maximum size (in KB) of audit log
                 auditLogSoreSleepActivity 1.3.6.1.4.1.3052.18.2.17.13 displaystring read-write
ON/OFF audit log stores sleep activity
           scripting 1.3.6.1.4.1.3052.18.2.18
                 scrGlobalEnable 1.3.6.1.4.1.3052.18.2.18.1 displaystring read-write
ON/OFF enable scripting
                 scrDTRCtrlPortEnableTable 1.3.6.1.4.1.3052.18.2.18.2 no-access
Table of DTR control port enables
                     scrDTRCtrlPortEnableEntry 1.3.6.1.4.1.3052.18.2.18.2.1 no-access
Entry for table of DTR control port enables
                         scrDTRCtrlPortEnableIndex 1.3.6.1.4.1.3052.18.2.18.2.1.1 integer32 read-only
Index for table of DTR control port enables
                         scrDTRCtrlPortEnable 1.3.6.1.4.1.3052.18.2.18.2.1.2 displaystring read-write
ON/OFF enable DTR control of scripting for this port
                 scrTable 1.3.6.1.4.1.3052.18.2.18.3 no-access
Table of scripts
                     scrEntry 1.3.6.1.4.1.3052.18.2.18.3.1 no-access
Entry for table of scripts
                         scrIndex 1.3.6.1.4.1.3052.18.2.18.3.1.1 integer32 read-only
Index for table of scripts
                         scrEnable 1.3.6.1.4.1.3052.18.2.18.3.1.2 displaystring read-write
ON/OFF enable this script
                         scrName 1.3.6.1.4.1.3052.18.2.18.3.1.3 displaystring read-write
Name of this script
                         scrFilename 1.3.6.1.4.1.3052.18.2.18.3.1.4 displaystring read-write
Filename for this script
                         scrRunAlways 1.3.6.1.4.1.3052.18.2.18.3.1.5 displaystring read-write
ON/OFF: this script always runs
                         scrRunAtStartup 1.3.6.1.4.1.3052.18.2.18.3.1.6 displaystring read-write
ON/OFF: this script runs at startup
                         scrRunScheduled 1.3.6.1.4.1.3052.18.2.18.3.1.7 displaystring read-write
ON/OFF: this script runs at a certain time of day
                         scrScheduleTime 1.3.6.1.4.1.3052.18.2.18.3.1.8 displaystring read-write
Time of day (HH:MM) this script is scheduled to run
                         scrArguments 1.3.6.1.4.1.3052.18.2.18.3.1.9 displaystring read-write
Arguments for this script
                         scrRepeatInterval 1.3.6.1.4.1.3052.18.2.18.3.1.10 integer32 read-write
How often this script runs (minutes)
                 scrVolatileStringTable 1.3.6.1.4.1.3052.18.2.18.4 no-access
Table of volatile string settings for use in scripts.
                     scrVolatileStringEntry 1.3.6.1.4.1.3052.18.2.18.4.1 no-access
Entry for table of volatile script string settings
                         scrVolatileStringIndex 1.3.6.1.4.1.3052.18.2.18.4.1.1 integer32 read-only
Index for table of volatile script string settings
                         scrVolatileString 1.3.6.1.4.1.3052.18.2.18.4.1.2 displaystring read-write
Volatile string for use in scripts. Use this object to cache frequently-changing string values or string values that do not need to persist through reset. This object corresponds to the scripting.vstring[] setting key branch; use those keys in scripts and you can view or change their values with this object.
                 scrVolatileIntTable 1.3.6.1.4.1.3052.18.2.18.5 no-access
Table of volatile integer settings for use in scripts.
                     scrVolatileIntEntry 1.3.6.1.4.1.3052.18.2.18.5.1 no-access
Entry for table of volatile script integer settings
                         scrVolatileIntIndex 1.3.6.1.4.1.3052.18.2.18.5.1.1 integer32 read-only
Index for table of volatile script integer settings
                         scrVolatileInt 1.3.6.1.4.1.3052.18.2.18.5.1.2 integer32 read-write
Volatile integer for use in scripts. Use this object to cache frequently-changing integer values or integer values that do not need to persist through reset. This object corresponds to the scripting.vint[] setting key branch; use those keys in scripts and you can view or change their values with this object.
                 scrNonVolatileStringTable 1.3.6.1.4.1.3052.18.2.18.6 no-access
Table of non-volatile string settings for use in scripts.
                     scrNonVolatileStringEntry 1.3.6.1.4.1.3052.18.2.18.6.1 no-access
Entry for table of non-volatile script string settings
                         scrNonVolatileStringIndex 1.3.6.1.4.1.3052.18.2.18.6.1.1 integer32 read-only
Index for table of non-volatile script string settings
                         scrNonVolatileString 1.3.6.1.4.1.3052.18.2.18.6.1.2 displaystring read-write
Non-volatile string for use in scripts. Use this object to store values that need to persist through reset. This object corresponds to the scripting.nvstring[] setting key branch; use those keys in scripts and you can view or change their values with this object. Note: to store frequently- changing integers, use the scrVolatileString object, otherwise your scripts may cause unnecessary wear of the non-volatile storage medium on the unit.
                 scrNonVolatileIntTable 1.3.6.1.4.1.3052.18.2.18.7 no-access
Table of non-volatile integer settings for use in scripts.
                     scrNonVolatileIntEntry 1.3.6.1.4.1.3052.18.2.18.7.1 no-access
Entry for table of non-volatile script integer settings
                         scrNonVolatileIntIndex 1.3.6.1.4.1.3052.18.2.18.7.1.1 integer32 read-only
Index for table of non-volatile script integer settings
                         scrNonVolatileInt 1.3.6.1.4.1.3052.18.2.18.7.1.2 integer32 read-write
Non-volatile integer for use in scripts. Use this object to store integer values that need to persist through reset. This object corresponds to the scripting.nvint[] setting key branch; use those keys in scripts and you can view or change their values with this object. Note: to store frequently- changing integers, use the scrVolatileInt object, otherwise your scripts may cause unnecessary wear of the non-volatile storage medium on the unit.
           generator 1.3.6.1.4.1.3052.18.2.19
                 genSet 1.3.6.1.4.1.3052.18.2.19.1
                     genSetEnable 1.3.6.1.4.1.3052.18.2.19.1.1 displaystring read-write
Enable genset functionality; that is, a generator is in use.
                     genSetRelay 1.3.6.1.4.1.3052.18.2.19.1.2
                         genSetRelayEs 1.3.6.1.4.1.3052.18.2.19.1.2.1 integer32 read-write
Which EventSensor has the relay which starts the generator, for genset relay configuration 1 only. This object maps to the same setting as genSetRelayTableEs.1.
                         genSetRelayPoint 1.3.6.1.4.1.3052.18.2.19.1.2.2 integer32 read-write
Which relay starts the generator, for genset relay configuration 1 only. This object maps to the same setting as genSetRelayTablePoint.1.
                         genSetRelayRunningstate 1.3.6.1.4.1.3052.18.2.19.1.2.3 displaystring read-write
Which relay state corresponds with the generator starting/running. This object maps to the same setting as genSetRelayTableRunningstate.1.
                         genSetRelayTable 1.3.6.1.4.1.3052.18.2.19.1.2.5 no-access
Table of relays for genset ignition.
                             genSetRelayTableEntry 1.3.6.1.4.1.3052.18.2.19.1.2.5.1 no-access
Entry for table of relays for genset ignition.
                                 genSetRelayTableIndex 1.3.6.1.4.1.3052.18.2.19.1.2.5.1.1 integer32 read-only
Index for table of relays for genset ignition.
                                 genSetRelayTableEnable 1.3.6.1.4.1.3052.18.2.19.1.2.5.1.2 displaystring read-write
Enable this relay for starting the generator.
                                 genSetRelayTableEs 1.3.6.1.4.1.3052.18.2.19.1.2.5.1.3 integer32 read-write
Which EventSensor has the relay which starts the generator, for this genset relay configuration specified by the table index.
                                 genSetRelayTablePoint 1.3.6.1.4.1.3052.18.2.19.1.2.5.1.4 integer32 read-write
Which relay point on the EventSensor used for starting the generator, for this genset relay configuration specified by the table index.
                                 genSetRelayTableRunningstate 1.3.6.1.4.1.3052.18.2.19.1.2.5.1.5 displaystring read-write
Which relay state corresponds with the generator starting/running, for this genset relay configuration specified by the table index.
                     genSetCC 1.3.6.1.4.1.3052.18.2.19.1.3
                         genSetCCEnable 1.3.6.1.4.1.3052.18.2.19.1.3.1 displaystring read-write
Enable generator running detection functionality; that is, the associated CC is valid for determining if generator is running.
                         genSetCCEs 1.3.6.1.4.1.3052.18.2.19.1.3.2 integer32 read-write
Which CC EventSensor has the CC which is connected to the genertor running detection monitor.
                         genSetCCPoint 1.3.6.1.4.1.3052.18.2.19.1.3.3 integer32 read-write
Which CC is connected to the genertor running detection monitor.
                         genSetCCRunningState 1.3.6.1.4.1.3052.18.2.19.1.3.4 displaystring read-write
Which CC physical state corresponds with the generator running.
                         genSetCCDelay 1.3.6.1.4.1.3052.18.2.19.1.3.5 integer32 read-write
How long (in seconds) to wait for the generator to indicate itself as running after engaging the generator-starting mechanism.
                 genRun 1.3.6.1.4.1.3052.18.2.19.2
                     genRunMode 1.3.6.1.4.1.3052.18.2.19.2.1 displaystring read-write
Generator Exercising function main operating mode; set to INHIBIT to inhibit exercising the generator.
                     genRunSched 1.3.6.1.4.1.3052.18.2.19.2.2 displaystring read-write
Schedule number(s) which govern(s) when Generator Exercising function runs.
                     genRunDuration 1.3.6.1.4.1.3052.18.2.19.2.3 integer32 read-write
Number of seconds that generator should run, started when the generator needs to start by SCHEDULE or by being forced to start.
                     genRunForce 1.3.6.1.4.1.3052.18.2.19.2.4 integer32 read-write
Write 1 to this to force the generator exercising to start. Always reads as 0.
                     genRunReqasm 1.3.6.1.4.1.3052.18.2.19.2.5 displaystring read-write
Require ASM connectivity before starting the generator from a schedule.
                     genRunStatus 1.3.6.1.4.1.3052.18.2.19.2.6 displaystring read-only
Status of Generator Exercising function.
                     genRunNonstartEvent 1.3.6.1.4.1.3052.18.2.19.2.7
                         genRunNonstartEventEnable 1.3.6.1.4.1.3052.18.2.19.2.7.1 displaystring read-write
Enable generator non-start event.
                         genRunNonstartEventActions 1.3.6.1.4.1.3052.18.2.19.2.7.2 displaystring read-write
Actions for generator non-start event.
                         genRunNonstartEventTrap 1.3.6.1.4.1.3052.18.2.19.2.7.3 integer32 read-write
Trap number for generator non-start event.
                         genRunNonstartEventClass 1.3.6.1.4.1.3052.18.2.19.2.7.4 displaystring read-write
Class (severity) for generator non-start event.
           calendar 1.3.6.1.4.1.3052.18.2.20
                 schedTable 1.3.6.1.4.1.3052.18.2.20.1 no-access
Table of schedules
                     schedEntry 1.3.6.1.4.1.3052.18.2.20.1.1 no-access
Entry for table of schedules.
                         schedIndex 1.3.6.1.4.1.3052.18.2.20.1.1.1 integer32 read-only
Index for table of schedules.
                         schedEnable 1.3.6.1.4.1.3052.18.2.20.1.1.2 displaystring read-write
Enable this schedule.
                         schedStart 1.3.6.1.4.1.3052.18.2.20.1.1.3 displaystring read-write
This is of the form 'mm/dd/yy hh:mm:ss'. This controls on which date/time the schedule starts.
                         schedRepeatMode 1.3.6.1.4.1.3052.18.2.20.1.1.4 displaystring read-write
Controls in which way the schedule should repeat.
                         schedRepeatFreq 1.3.6.1.4.1.3052.18.2.20.1.1.5 integer32 read-write
Controls how often the schedule should repeat: every nth day, week, month, or year.
                         schedRepeatEndMode 1.3.6.1.4.1.3052.18.2.20.1.1.6 displaystring read-write
Controls how the repeating schedule should end.
                         schedRepeatEndAfter 1.3.6.1.4.1.3052.18.2.20.1.1.7 integer32 read-write
Number of times this schedule should be repeated; relevant when the repeat end mode is AFTER.
                         schedRepeatEndOn 1.3.6.1.4.1.3052.18.2.20.1.1.8 displaystring read-write
Date/time (in the form 'mm/yy/dd hh:mm:ss' or blank string) after which repeating should end, relevant when repeat end mode is ON DATE.
                         schedRepeatWeeklySun 1.3.6.1.4.1.3052.18.2.20.1.1.9 displaystring read-write
Run this schedule on Sunday(s); relevant when repeat mode is weekly.
                         schedRepeatWeeklyMon 1.3.6.1.4.1.3052.18.2.20.1.1.10 displaystring read-write
Run this schedule on Monday(s); relevant when repeat mode is weekly.
                         schedRepeatWeeklyTue 1.3.6.1.4.1.3052.18.2.20.1.1.11 displaystring read-write
Run this schedule on Tuesday(s); relevant when repeat mode is weekly.
                         schedRepeatWeeklyWed 1.3.6.1.4.1.3052.18.2.20.1.1.12 displaystring read-write
Run this schedule on Wednesday(s); relevant when repeat mode is weekly.
                         schedRepeatWeeklyThu 1.3.6.1.4.1.3052.18.2.20.1.1.13 displaystring read-write
Run this schedule on Thursday(s); relevant when repeat mode is weekly.
                         schedRepeatWeeklyFri 1.3.6.1.4.1.3052.18.2.20.1.1.14 displaystring read-write
Run this schedule on Friday(s); relevant when repeat mode is weekly.
                         schedRepeatWeeklySat 1.3.6.1.4.1.3052.18.2.20.1.1.15 displaystring read-write
Run this schedule on Saturday(s); relevant when repeat mode is weekly.
                         schedRepeatMonthlyMode 1.3.6.1.4.1.3052.18.2.20.1.1.16 displaystring read-write
EACH means the schedule runs on specific dates of the month. ON THE means the schedule runs on calculated dates of the month according to which day that month starts.
                         schedRepeatMonthlyDates 1.3.6.1.4.1.3052.18.2.20.1.1.17 displaystring read-write
Comma-separated list of dates of a month on which this schedule should run, relevant when repeat monthly mode is EACH.
                         schedRepeatMonthlyOnThe 1.3.6.1.4.1.3052.18.2.20.1.1.18 displaystring read-write
Controls on which day of the month this schedule should run, relevant when repeat monthly mode is ON THE.
                         schedRepeatMonthlyOnDay 1.3.6.1.4.1.3052.18.2.20.1.1.19 displaystring read-write
Controls the day of week on which this schedule is run, relevant when repeat monthly mode is ON THE
                         schedRepeatYearlyJan 1.3.6.1.4.1.3052.18.2.20.1.1.20 displaystring read-write
Run this schedule in January, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyFeb 1.3.6.1.4.1.3052.18.2.20.1.1.21 displaystring read-write
Run this schedule in February, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyMar 1.3.6.1.4.1.3052.18.2.20.1.1.22 displaystring read-write
Run this schedule in March, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyApr 1.3.6.1.4.1.3052.18.2.20.1.1.23 displaystring read-write
Run this schedule in April, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyMay 1.3.6.1.4.1.3052.18.2.20.1.1.24 displaystring read-write
Run this schedule in May, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyJun 1.3.6.1.4.1.3052.18.2.20.1.1.25 displaystring read-write
Run this schedule in June, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyJul 1.3.6.1.4.1.3052.18.2.20.1.1.26 displaystring read-write
Run this schedule in July, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyAug 1.3.6.1.4.1.3052.18.2.20.1.1.27 displaystring read-write
Run this schedule in August, relevant when repeat mode is YEARLY.
                         schedRepeatYearlySep 1.3.6.1.4.1.3052.18.2.20.1.1.28 displaystring read-write
Run this schedule in September, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyOct 1.3.6.1.4.1.3052.18.2.20.1.1.29 displaystring read-write
Run this schedule in October, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyNov 1.3.6.1.4.1.3052.18.2.20.1.1.30 displaystring read-write
Run this schedule in November, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyDec 1.3.6.1.4.1.3052.18.2.20.1.1.31 displaystring read-write
Run this schedule in December, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyOnThe 1.3.6.1.4.1.3052.18.2.20.1.1.32 displaystring read-write
Controls on which day of the month this schedule should run, relevant when repeat mode is YEARLY.
                         schedRepeatYearlyOnDay 1.3.6.1.4.1.3052.18.2.20.1.1.33 displaystring read-write
Controls the day of week on which this schedule is run, relevant when repeat mode is YEARLY.
                         schedNextTrigger 1.3.6.1.4.1.3052.18.2.20.1.1.34 displaystring read-only
When this schedule will next trigger.
       productIds 1.3.6.1.4.1.3052.18.3
           siteName 1.3.6.1.4.1.3052.18.3.1 displaystring read-only
Site Name string; Max 40 characters.
           thisProduct 1.3.6.1.4.1.3052.18.3.2 displaystring read-only
This is a factory configured string for the product name.
           stockTrapString 1.3.6.1.4.1.3052.18.3.3 displaystring read-only
The message defined for the event that triggers a trap.
           trapEventTypeNumber 1.3.6.1.4.1.3052.18.3.4 integer32 read-only
The user-defined trap variable for the type of event that happened. Definitions: 4 Scheduled 7 Serial Handshaking Low 8 Serial Handshaking High 10 Contact Closure Active 11 Contact Closure Inactive 12 Temperature High 13 Temperature Very High 14 Temperature Low 15 Temperature Very Low 16 Temperature Return to Normal 17 Humidity High 18 Humidity Very High 19 Humidity Low 20 Humidity Very Low 21 Humidity Return to Normal 26 Analog High 27 Analog Very High 28 Analog Low 29 Analog Very Low 30 Analog Normal 40 EventSensor Unresponsive 41 Custom 42 CPE Down 44 CPE Normal 49 Fuel Sensor Disconnect 50 Fuel Sensor Disconnect Return to Normal 56 Fuel Sensor 57 AC Power Monitor Average Voltage Very Low 58 AC Power Monitor Average Voltage Low 59 AC Power Monitor Average Voltage Return to Normal 60 AC Power Monitor Average Voltage High 61 AC Power Monitor Average Voltage Very High 62 AC Power Monitor Average Current Very Low 63 AC Power Monitor Average Current Low 64 AC Power Monitor Average Current Return to Normal 65 AC Power Monitor Average Current High 66 AC Power Monitor Average Current Very High 67 AC Power Monitor Frequency Very Low 68 AC Power Monitor Frequency Low 69 AC Power Monitor Frequency Return to Normal 70 AC Power Monitor Frequency High 71 AC Power Monitor Frequency Very High 72 AC Power Monitor Total Real Power Very Low 73 AC Power Monitor Total Real Power Low 74 AC Power Monitor Total Real Power Return to Normal 75 AC Power Monitor Total Real Power High 76 AC Power Monitor Total Real Power Very High 77 AC Power Monitor Disconnect 78 AC Power Monitor Disconnect Return to Normal 81 Fuel Sensor Volume Sudden Change 82 Fuel Sensor Volume Slow Change 83 CPE Down Reminder 84 AC Power Monitor Total Power Factor Very Low 85 AC Power Monitor Total Power Factor Low 86 AC Power Monitor Total Power Factor Return to Normal 100 Contact Closure Active Reminder 101 Temperature High Reminder 102 Temperature High Very Reminder 103 Temperature Low Reminder 104 Temperature Very Low Reminder 105 Humidity High Reminder 106 Humidity Very High Reminder 107 Humidity Low Reminder 108 Humidity Very Low Reminder 109 Analog High Reminder 110 Analog Very High Reminder 111 Analog Low Reminder 112 Analog Very Low Reminder 130 Relay Output Active 131 Relay Output Inactive 132 Power Output On 133 Power Output Off 134 Battery Monitor Temperature High 135 Battery Monitor Temperature Return to Normal 136 Battery Monitor Temperature Low 137 Battery Monitor Differential Temperature High 138 Battery Monitor Differential Temperature Return to Normal 139 Battery Monitor Differential Temperature Low 140 Battery Monitor Voltage Very High 141 Battery Monitor Voltage High 142 Battery Monitor Voltage Return to Normal 143 Battery Monitor Voltage Low 144 Battery Monitor Voltage Very Low 145 Battery Monitor Differential Voltage Very High 146 Battery Monitor Differential Voltage High 147 Battery Monitor Differential Voltage Return to Normal 148 Battery Monitor Charge Level Return to Normal 149 Battery Monitor Charge Level Low 150 Battery Monitor Charge Level Very Low 151 Battery Monitor Health Return to Normal 152 Battery Monitor Health Low 153 Battery Monitor Health Very Low 154 Battery Monitor Charge Current Very High 155 Battery Monitor Charge Current High 156 Battery Monitor Charge Current Return to Normal 157 Battery Monitor Discharge Current Very High 158 Battery Monitor Discharge Current High 159 Battery Monitor Discharge Return to Normal 160 Generator Failed to Start 162 Location Fix Failure 163 Location Fix Success 164 Reset 165 Sleep 166 Fuel Sensor Levels Auto Adjust
           trapEventTypeName 1.3.6.1.4.1.3052.18.3.5 displaystring read-only
The user-defined trap variable for the string corresponding to the event type.
           trapIncludedValue 1.3.6.1.4.1.3052.18.3.6 integer32 read-only
The user-defined trap variable for the generic included value.
           trapIncludedString 1.3.6.1.4.1.3052.18.3.7 displaystring read-only
The user-defined trap variable for the generic included string.
           trapTypeString 1.3.6.1.4.1.3052.18.3.8 displaystring read-only
The cause of the trap, added for DL880 compatibility.
           trapEventClassNumber 1.3.6.1.4.1.3052.18.3.9 integer32 read-only
The user-defined trap variable for the configurable class number associated with the triggering event.
           trapEventClassName 1.3.6.1.4.1.3052.18.3.10 displaystring read-only
The user-defined trap variable for the configurable class name associated with the class number.
       keyInterface 1.3.6.1.4.1.3052.18.4 displaystring read-write
This object represents a setting key interface. When setting this object, the value to set is the 'sk' command you would enter on the command line (without the 'sk'). To get the result of the operation, read this object after you write it. For example, to configure EventSensor 1 contact closure 34 event actions to be an SNMP InformRequest to host foo, set this object to: 'event.sensor[1].cc[34].eventactions=inform(foo)'. The SNMP response is the result of the operation: if setting that key to that value was a success then the SNMP response will be a success and the response value will be what you had set. If you subsequently read this object then you will see a message 'OK: ...'. If setting that key to that value failed then the SNMP response will be a failure (a badValue response). If you subsequently read this object then the value returned is the reason that setting that key to that value failed. For another example, to read user 3's pass-through access for port 7, set this object to: 'sec.user[3].port[7].ptaccess'. The SNMP response is the result of the operation: if reading that key is a success then the SNMP response will be a success and the response value will be what you had SET (i.e., the opertion of reading a key, which is just the key itself with no '=' operator, and this is not the key value you want to read). If you subsequently read this object then the value returned is the value of the key you want to read. If reading that key failed (e.g., if the key is invalid) then the SNMP response to your SNMP set operation (the value you set being the invalid key to read) will be a failure (a badValue response). If you subsequently read this object then the value returned is the reason that reading that key failed (i.e., 'invalid key').