Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 sync 1.3.6.1.4.1.3373.1103.28
Timing Source Management.
       syncMibVersion 1.3.6.1.4.1.3373.1103.28.1 integer read-only
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.
       timingGeneratorTable 1.3.6.1.4.1.3373.1103.28.2 no-access
Table with TimingGenerator records.
           timingGeneratorRecord 1.3.6.1.4.1.3373.1103.28.2.1 no-access
TimingGenerator record.
               timingGeneratorId 1.3.6.1.4.1.3373.1103.28.2.1.1 integer32 read-only
This object is used as Index of the Timing Generator Table.
               timingGeneratorT4vsT0 1.3.6.1.4.1.3373.1103.28.2.1.2 integer read-only
This object is used to set or reset the condition T4 equal T0. Enumeration: 't4NotEqualT0': 1, 't4EqualT0': 2.
               timingGeneratorHoldOffTime 1.3.6.1.4.1.3373.1103.28.2.1.3 integer read-only
HoldOff time in milliseconds (300..1800).
               timingGeneratorWtrTime 1.3.6.1.4.1.3373.1103.28.2.1.4 integer read-only
Wait Time to Restore in minutes (0..12).
               timingGeneratorSinkLosSet 1.3.6.1.4.1.3373.1103.28.2.1.5 integer read-only
Wait time (seconds) before to set Los of reference signal.
               timingGeneratorSinkLosReset 1.3.6.1.4.1.3373.1103.28.2.1.6 integer read-only
Wait time (seconds) before to reset Los of reference signal.
               timingGeneratorT0SquelchAlarm 1.3.6.1.4.1.3373.1103.28.2.1.7 alarmstatus read-only
T0 squelch Alarm (Probable cause = xxx) with associated severity.
               timingGeneratorT4SquelchAlarm 1.3.6.1.4.1.3373.1103.28.2.1.8 alarmstatus read-only
T4 squelch Alarm (Probable cause = xxx) with associated severity.
               timingGeneratorFreeRunningStatus 1.3.6.1.4.1.3373.1103.28.2.1.9 alarmstatus read-only
Free running status (Probable cause = xxx) with associated severity.
               timingGeneratorHoldoverStatus 1.3.6.1.4.1.3373.1103.28.2.1.10 alarmstatus read-only
Holdover status (Probable cause = xxx) with associated severity.
               timingGeneratorActiveStatus 1.3.6.1.4.1.3373.1103.28.2.1.11 integer read-only
Active status (Probable cause = xxx) with associated severity. Enumeration: 'activeReportableStatus': 2, 'cleared': 1.
               timingGeneratorT0CurrentQuality 1.3.6.1.4.1.3373.1103.28.2.1.12 integer read-only
Current quality on T0. Enumeration: 'qUNKN': 0, 'qSEC': 11, 'qSSUL': 8, 'qDNU': 15, 'qSSUT': 4, 'qPRC': 2.
               timingGeneratorT4CurrentQuality 1.3.6.1.4.1.3373.1103.28.2.1.13 integer read-only
Current quality on T4. Enumeration: 'qUNKN': 0, 'qSEC': 11, 'qSSUL': 8, 'qDNU': 15, 'qSSUT': 4, 'qPRC': 2.
               timingGeneratorT4MinimumQuality 1.3.6.1.4.1.3373.1103.28.2.1.14 integer read-only
If the Quality Level of the signal used to derive T4 falls below timingGeneratorT4MinimumQuality then the output will be squelched. The value ql-DNU inhibits T4 squelch due to this minimum Quality Level. This feature is enabled by timingGeneratorT4Squelch when timingGeneratorQualityEnable is on(2). Enumeration: 'qSEC': 11, 'qSSUT': 4, 'qPRC': 2, 'qSSUL': 8.
               timingGeneratorT0PreferredSource 1.3.6.1.4.1.3373.1103.28.2.1.15 object identifier read-only
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as preferential clock source of T0. If no preferential timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
               timingGeneratorT4PreferredSource 1.3.6.1.4.1.3373.1103.28.2.1.16 object identifier read-only
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as preferential clock source of T4. If no preferential timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
               timingGeneratorRowStatus 1.3.6.1.4.1.3373.1103.28.2.1.17 rowstatus read-only
Status of this row of timingGeneratorTable.
       timingGeneratorMaintTable 1.3.6.1.4.1.3373.1103.28.3 no-access
Table with TimingGenerator records.
           timingGeneratorMaintRecord 1.3.6.1.4.1.3373.1103.28.3.1 no-access
TimingGenerator record.
               timingGeneratorT4Squelch 1.3.6.1.4.1.3373.1103.28.3.1.1 integer read-write
This object is used to enable/disable T4 squelch. Enumeration: 'enable': 2, 'disable': 1.
               timingGeneratorStatusControl 1.3.6.1.4.1.3373.1103.28.3.1.2 integer read-write
Clock generator operating mode control. This item is linked to a manual operation (ManOpRecord) instance. Enumeration: 'freerunning': 1, 'locked': 3, 'holdover': 2.
               timingGeneratorT0ForcedSource 1.3.6.1.4.1.3373.1103.28.3.1.3 object identifier read-write
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as forced clock source of T0. If no forced timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
               timingGeneratorT4ForcedSource 1.3.6.1.4.1.3373.1103.28.3.1.4 object identifier read-write
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as forced clock source of T4. If no forced timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
               timingGeneratorWtrClearSource 1.3.6.1.4.1.3373.1103.28.3.1.5 object identifier read-write
Object identifier of the leaf timingSinkGenId of the timingSink instance selected to clear WTR time. On read, this object return alvays an OBJECT IDENTIFIER {0 0}.
       timingSinkTable 1.3.6.1.4.1.3373.1103.28.4 no-access
Table with TimingSink records.
           timingSinkRecord 1.3.6.1.4.1.3373.1103.28.4.1 no-access
TimingSink record.
               timingSinkGenId 1.3.6.1.4.1.3373.1103.28.4.1.1 integer32 read-only
This object is used as Index of the timingGeneratorTable and defines in union with timingSinkType and timingSinkId the reference signal.
               timingSinkId 1.3.6.1.4.1.3373.1103.28.4.1.2 integer32 read-only
This object is used as Index of the timingSinkTable and defines in union with timingSinkType and timingSinkGenId the reference signal.
               timingSinkType 1.3.6.1.4.1.3373.1103.28.4.1.3 integer read-only
This object is used as Index of the timingSinkTable and defines if the reference signal is used to generate T0 or T4 system clock. Enumeration: 't4': 2, 't0': 1.
               timingSinkIfIndex 1.3.6.1.4.1.3373.1103.28.4.1.4 interfaceindexorzero read-only
The ifIndex value the agent selected for this timingSink interface.
               timingSinkSelector 1.3.6.1.4.1.3373.1103.28.4.1.5 integer32 read-only
This object is used to select one of the possible clock source connected to this timingSink. Valid values are listed in timingSinkSelectorTable: only values of timingSinkSelectorId related to this instance of timinkSinkRecord are accepted. Only the values corresponding to the index timingSinkSelectorId of timinkSinkSelectorTable related to this instance of timinkSinkRecord will be accepted.
               timingSinkPriority 1.3.6.1.4.1.3373.1103.28.4.1.6 integer read-only
This object is used to set the priority of the reference signal (p1 is the highest priority). Enumeration: 'p2': 2, 'p3': 3, 'p1': 1, 'p6': 6, 'p7': 7, 'p4': 4, 'p5': 5, 'p13': 13, 'p8': 8, 'p9': 9, 'p10': 10, 'p11': 11, 'p12': 12, 'disable': 16, 'p14': 14, 'p15': 15.
               timingSinkLabel 1.3.6.1.4.1.3373.1103.28.4.1.7 displaystring read-only
ASCII string used to describe the reference signal when a trap is sent.
               timingSinkLosAlarm 1.3.6.1.4.1.3373.1103.28.4.1.8 alarmstatus read-only
Loss of reference signal (Probable cause = xxx) alarm with associated severity.
               timingSinkDriftAlarm 1.3.6.1.4.1.3373.1103.28.4.1.9 alarmstatus read-only
Drift of reference signal (Probable cause = xxx) alarm with associated severity.
               timingSinkActiveStatus 1.3.6.1.4.1.3373.1103.28.4.1.10 integer read-only
Active status (Probable cause = xxx) status for the reference signal. Enumeration: 'activeReportableStatus': 2, 'cleared': 1.
               timingSinkCurrentQuality 1.3.6.1.4.1.3373.1103.28.4.1.11 integer read-only
Current quality on sink instance. Enumeration: 'qUNKN': 0, 'qSEC': 11, 'qSSUL': 8, 'qDNU': 15, 'qSSUT': 4, 'qPRC': 2.
               timingSinkOverwriteTxQuality 1.3.6.1.4.1.3373.1103.28.4.1.12 integer read-only
Forcing of Tx quality parameter. Enumeration: 'qSEC': 11, 'qSSUL': 8, 'noOverwrite': 0, 'qDNU': 15, 'qSSUT': 4, 'qPRC': 2.
               timingSinkOverwriteRxQuality 1.3.6.1.4.1.3373.1103.28.4.1.13 integer read-only
Forcing of Rx quality parameter. Enumeration: 'qSEC': 11, 'qSSUL': 8, 'noOverwrite': 0, 'qDNU': 15, 'qSSUT': 4, 'qPRC': 2.
               timingSinkSentQuality 1.3.6.1.4.1.3373.1103.28.4.1.14 integer read-only
Quality level written in the S1 byte of the outgoing STM-n. Enumeration: 'qUNKN': 0, 'qSEC': 11, 'qSSUL': 8, 'qDNU': 15, 'qSSUT': 4, 'qPRC': 2.
               timingSinkE1Sabit 1.3.6.1.4.1.3373.1103.28.4.1.15 integer read-only
Specifies the San synchronization status bit used to indicate the clock quality level. Meaningful when the Sink source is an E1
               timingSinkEthPortRole 1.3.6.1.4.1.3373.1103.28.4.1.16 integer read-only
This item configures how to handle the role of a 1000BASE-T port when it is used as a source of timing: choosing 'static', the role is set according ethLanPhyTable settings, choosing 'dynamic', the role is set consistently with the timing direction over the 1000baseT link chosen by SSM protocol. Enumeration: 'static': 1, 'dynamic': 2.
               timingSinkRowStatus 1.3.6.1.4.1.3373.1103.28.4.1.17 rowstatus read-only
Status of this row of timingSinkTable
       timingGeneratorManualSwitch 1.3.6.1.4.1.3373.1103.28.5 integer32 read-write
timingGeneratorId of the forced timingGenerator instance. If no preferred timing generator is selected, the value should be set to 0.
       timingGeneratorForcedSwitch 1.3.6.1.4.1.3373.1103.28.6 integer32 read-write
timingGeneratorId of the forced timingGenerator instance. If no forced timing generator is selected, the value should be set to 0.
       timingGeneratorT0SquelchAlarmSeverityCode 1.3.6.1.4.1.3373.1103.28.7 alarmseveritycode read-write
Defines the severity associated to the TimingGeneratorT0SquelchAlarm and enables/disables the trap generation on status change event.
       timingGeneratorT4SquelchAlarmSeverityCode 1.3.6.1.4.1.3373.1103.28.8 alarmseveritycode read-write
Defines the severity associated to the timingGeneratorT4SquelchAlarm and enables/disables the trap generation on status change event.
       timingGeneratorFreeRunningStatusSeverityCode 1.3.6.1.4.1.3373.1103.28.9 alarmseveritycode read-write
Defines the severity associated to the timingGeneratorFreeRunningStatus and enables/disables the trap generation on status change event.
       timingGeneratorHoldoverStatusSeverityCode 1.3.6.1.4.1.3373.1103.28.10 alarmseveritycode read-write
Defines the severity associated to the timingGeneratorHoldoverStatus and enables/disables the trap generation on status change event.
       timingGeneratorActiveStatusSeverityCode 1.3.6.1.4.1.3373.1103.28.11 integer read-write
Defines the severity associated to the timingGeneratorActiveStatus and enables/disables the trap generation on status change event. Enumeration: 'disable': 1, 'statusTrapEnable': 2.
       timingGeneratorQualityEnable 1.3.6.1.4.1.3373.1103.28.12 integer read-write
Quality policy enable Enumeration: 'on': 2, 'off': 1.
       timingSinkLosAlarmSeverityCode 1.3.6.1.4.1.3373.1103.28.13 alarmseveritycode read-write
Defines the severity associated to the TimingSinkLosAlarm and enables/disables the trap generation on status change event.
       timingSinkDriftAlarmSeverityCode 1.3.6.1.4.1.3373.1103.28.14 alarmseveritycode read-write
Defines the severity associated to the TimingSinkDriftAlarm and enables/disables the trap generation on status change event.
       timingSinkActiveStatusSeverityCode 1.3.6.1.4.1.3373.1103.28.15 integer read-write
Defines the severity associated to the timingSinkActiveStatus and enables/disables the trap generation on status change event. Enumeration: 'disable': 1, 'statusTrapEnable': 2.
       timingSinkSelectorTable 1.3.6.1.4.1.3373.1103.28.16 no-access
Table with TimingSinkSelector records.
             timingSinkSelectorRecord 1.3.6.1.4.1.3373.1103.28.16.1 no-access
TimingSinkSelector entry. Several instances of this entry can be create for each instance of timingSinkTable. Each entry represents a possible source selected by a multiplexer outside the SETS for a specific timingSink. Only the values corresponding to the index timingSinkSelectorId can be set to timingSinkSelector.
                 timingSinkSelectorId 1.3.6.1.4.1.3373.1103.28.16.1.1 integer32 read-only
This object is used as Index of the timingSinkSelectorTable and defines in union with timingSinkGenId, timingSinkType and timingSinkId the selected source by a multiplexer outside the SETS.
                 timingSinkSelectorLabel 1.3.6.1.4.1.3373.1103.28.16.1.2 displaystring read-only
ASCII string used to describe the selectable timing source.
       esmcTable 1.3.6.1.4.1.3373.1103.28.17 no-access
Table with TimingSinkSelector records.
             esmcRecord 1.3.6.1.4.1.3373.1103.28.17.1 no-access
esmcTable entry. Every entries describes an ESMC channel of a TE interface.
                 esmcSsmEnable 1.3.6.1.4.1.3373.1103.28.17.1.1 integer read-only
This object enables SSM messaging on this ifIndex. Enumeration: 'enable': 2, 'disable': 1.
                 esmcQlRx 1.3.6.1.4.1.3373.1103.28.17.1.2 integer read-only
This object show quality received on ESMC-PDU this interface. Enumeration: 'qUNKN': 0, 'qSEC': 11, 'qSSUL': 8, 'qDNU': 15, 'qSSUT': 4, 'qPRC': 2.
                 esmcQlTx 1.3.6.1.4.1.3373.1103.28.17.1.3 integer read-only
This object show quality transmitted in ESMC-PDU on this interface. Enumeration: 'qUNKN': 0, 'qSEC': 11, 'qSSUL': 8, 'qDNU': 15, 'qSSUT': 4, 'qPRC': 2.
                 esmcPktsRx 1.3.6.1.4.1.3373.1103.28.17.1.4 counter32 read-only
This object contains the total number of received ESMC-PDU packets on this interface.
                 esmcPktsTx 1.3.6.1.4.1.3373.1103.28.17.1.5 counter32 read-only
This object contains the total number of transmitted ESMC-PDU packets on this interface.
                 esmcPktsRxDropped 1.3.6.1.4.1.3373.1103.28.17.1.6 counter32 read-only
This object contains the total number of dropped ESMC-PDU packets on this interface.
                 esmcPktsRxErrored 1.3.6.1.4.1.3373.1103.28.17.1.7 counter32 read-only
This object contains the total number of dropped ESMC-PDU packets whose processing(decoding) resulted into error.
                 esmc1000BaseTRole 1.3.6.1.4.1.3373.1103.28.17.1.8 integer read-only
This object allows to input the clock generator role of a 1000BaseT interface. This objects is applicable when the quality management is disabled (timingGeneratorQualityEnable set to off(1)) and to all interfaces not connected to any timingSink when the quality management is enabled. Enumeration: 'slave': 1, 'master': 2, 'auto': 3.
                 esmcRowStatus 1.3.6.1.4.1.3373.1103.28.17.1.9 rowstatus read-only
Status of this row of esmcTable.