SIAE-SFP-MIB: View SNMP OID List / Download MIB

VENDOR: SIAE MICROELETTRONICA S.P.A.


 Home MIB: SIAE-SFP-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 sfp 1.3.6.1.4.1.3373.1103.74
This MIB contains objects & alarms for a SFP (Small Form-Factor Pluggable) module. Reference documentation: 1) Small Form-factor Pluggable (SFP) Transceiver MultiSource Agreement (MSA) 2) Finisar's Application Note AN-2030, Rev. D. 3) SFF 8472 - Diagnostic Monitoring Interface for Optical Transceivers Rev 12.2 November 21, 2014 4) SFF 8024 - SFF Cross Reference to Industry Products Rev 4.0 June 27, 2016
       sfpMibVersion 1.3.6.1.4.1.3373.1103.74.1 integer read-only
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.
       sfpSerialIdTable 1.3.6.1.4.1.3373.1103.74.2 no-access
Each SFP contains a 95+32 byte block of ID data fields. This table contains the items found in this data block. Fields in this data block is filled in by the SFP manufactor. The table shows the contents of this data block without further processing.
           sfpSerialIdEntry 1.3.6.1.4.1.3373.1103.74.2.1 no-access
SFP module record.
               sfpModuleId 1.3.6.1.4.1.3373.1103.74.2.1.1 integer32 read-only
This index identifies a unique SFP module in the system
               sfpSerialIdValid 1.3.6.1.4.1.3373.1103.74.2.1.2 truthvalue read-only
When false the SFP data in this table is not valid. This will be set to False if the SFP module is not installed or if the EEPROM check code is wrong. The data in this table should not be used unless this element is True.
               sfpVendorName 1.3.6.1.4.1.3373.1103.74.2.1.3 octet string read-only
The SFP vendor name. Located at I2C address 0xa0, bytes: 20 - 35
               sfpVendorPartNumber 1.3.6.1.4.1.3373.1103.74.2.1.4 octet string read-only
The SFP vendor part number. Located at I2C address 0xa0, bytes: 40 - 55
               sfpVendorRev 1.3.6.1.4.1.3373.1103.74.2.1.5 octet string read-only
The SFP vendor's product revision number. Located at I2C address 0xa0, bytes: 56 - 59
               sfpVendorSN 1.3.6.1.4.1.3373.1103.74.2.1.6 octet string read-only
The SFP vendor serial number. Located at I2C address 0xa0, bytes: 68 - 83
               sfpVendorDateCode 1.3.6.1.4.1.3373.1103.74.2.1.7 octet string read-only
The SFP vendor date code. Format: YYMMDDLL - YY: year, 00 = 2000 - MM: month, 01 = January - DD_ day, 01 to 31 - LL: vendor lot code, or blank. Located at I2C address 0xa0, bytes: 84 - 91
               sfpDiagMonitorCode 1.3.6.1.4.1.3373.1103.74.2.1.8 bits read-only
This indicates which type of diagnostic monitoring is implemented (if any) in the SFP. -bit 7: = 0 legacy diagnostic implementations (should be 0) -bit 6: = 1 digital diagnostic monitoring implemented (should be 1) -bit 5: = 1 internal calibration -bit 4: = 1 external calibration mask -bit 3: = 0 OMA received power measurment, = 1 average received power -bit 2: = 1 I2C addressing option. Located at I2C address 0xa0, byte: 92 Bits: 'sfpDMCtypeExternalCal': 3, 'sfpDMCtypeImplemented': 1, 'sfpDMCtypeLegacy': 0, 'sfpDMCtypeAddrChngReqrd': 5, 'sfpDMCtypeInternalCal': 2, 'sfpDMCtypeRxAvgPwr': 4.
               sfpEnhancedOptionsCode 1.3.6.1.4.1.3373.1103.74.2.1.9 bits read-only
This indicates which optional enhanced features are implemented (if any) in the SFP. Located at I2C address 0xa0, byte: 93 Bits: 'sfpEOCSoftRxLOS': 3, 'sfpEOCalarmsImplemented': 0, 'sfpEOCSoftRateSelect': 4, 'sfpEOCSoftTxDisable': 1, 'sfpEOCSoftTxFault': 2.
               sfpOptions 1.3.6.1.4.1.3373.1103.74.2.1.10 bits read-only
Implemented transceiver options: -bit 5: = 1 RATE_SELECT implemented. -bit 4: = 1 TX_DISABLE implemented -bit 3: = 1 TX_FAULT implemented -bit 2: = 1 LOS Implemented, inverted -bit 1: = 1 LOS Implemented Located at I2C address 0xa0, byte: 65 Bits: 'sfpOPTTxFault': 2, 'sfpOPTRateSelect': 0, 'sfpOPTTxDisable': 1, 'sfpOPTInvertedLOS': 3, 'sfpOPTlos': 4.
               sfpFibreChannelMedia 1.3.6.1.4.1.3373.1103.74.2.1.11 bits read-only
Fiber Channel transmission media. Located at I2C address 0xa0, byte: 9 Bits: 'sfpSingleMode': 2, 'sfpMultiMode50u0': 1, 'sfpShieldedTwistedPair': 4, 'sfpVideoCoax': 6, 'sfpMiniatureCoax': 5, 'sfpTwistedAxialPair': 3, 'sfpMultiMode62u5': 0.
               sfpCompliance 1.3.6.1.4.1.3373.1103.74.2.1.12 bits read-only
Electronic or optical interfaces that are supported by the transceiver. Located at I2C address 0xa0, bytes: 4,5 & 6 Bits: 'sfpSonetOC3ShortReach': 10, 'sfp1000BaseLX': 13, 'sfpSonetOC12LongReach': 5, 'sfp100BaseFX': 17, 'sfpSonetOC12ShortReach': 7, 'sfpBaseBX10': 16, 'sfpSonetOC3IntermediateReach': 9, 'sfp1000BaseCX': 12, 'sfpSonetOC3LongReach': 8, 'sfpSonetOC48IntermediateReach': 3, 'sfpSonetOC12IntermediateReach': 6, 'sfpSonetOC48LongReach': 2, 'sfpSonetOC48ShortReach': 4, 'sfp1000BaseT': 11, 'sfpSonetReachSpecifier2': 1, 'sfpSonetReachSpecifier1': 0, 'sfp100BaseLX': 18, 'sfp1000baseSX': 14, 'sfpBasePX': 15.
               sfpWavelength 1.3.6.1.4.1.3373.1103.74.2.1.13 integer32 read-only
Nominal transmiter output wavelength at room temperature. Units are in nm (nanometers). Located at I2C address 0xa0, bytes: 60 & 61 (endianess: big)
               sfpNominalBitRate 1.3.6.1.4.1.3373.1103.74.2.1.14 integer32 read-only
Nominal bit rate (in megabit per second) supported from this SFP module rouded to the nearest 100 megabits per second. Located at I2C address 0xa0, byte: 12
               sfpLinkLength9u 1.3.6.1.4.1.3373.1103.74.2.1.15 integer32 read-only
Link length (in meters) supported from this SFP module while operating in compliance with the applicable standards using single mode fiber. A value of zero means that the transceiver does not support single mode fiber. Located at I2C address 0xa0, bytes: 14-15
               sfpLinkLength50u 1.3.6.1.4.1.3373.1103.74.2.1.16 integer32 read-only
Link length (in meters) supported from this SFP module while operating in compliance with the applicable standards using 50 micron multi-mode fiber. A value of zero means that the transceiver does not support 50 micron multi-mode mode fiber. Located at I2C address 0xa0, byte: 16
               sfpLinkLength62u5 1.3.6.1.4.1.3373.1103.74.2.1.17 integer32 read-only
Link length (in meters) supported from this SFP module while operating in compliance with the applicable standards using 62.5 micron multi-mode fiber. A value of zero means that the transceiver does not support 62.5 micron multi-mode mode fiber. Located at I2C address 0xa0, byte: 17
               sfpLinkLengthCopper 1.3.6.1.4.1.3373.1103.74.2.1.18 integer32 read-only
Link length (in meters) supported from this SFP module while operating in compliance with the applicable standards using copper cable. A value of zero means that the transceiver does not support copper cable. Located at I2C address 0xa0, byte: 18
               sfpLabel 1.3.6.1.4.1.3373.1103.74.2.1.19 displaystring read-only
This is an ASCII string that identifies this SFP in the system.
               sfpFailAlarm 1.3.6.1.4.1.3373.1103.74.2.1.20 alarmstatus read-only
SFP Module fail (module missing included)
       sfpFailAlarmSeverityCode 1.3.6.1.4.1.3373.1103.74.6 alarmseveritycode read-write
Defines the severity associated to the sfpFailAlarm and enables/disables the trap generation on status change event.
       sfpDiagnosticTable 1.3.6.1.4.1.3373.1103.74.7 no-access
Each SFP may contain a 256 byte block of diagnostic data fields. This table contains the items found in this data block. The data block is located at I2C address 0xa2.
           sfpDiagnosticEntry 1.3.6.1.4.1.3373.1103.74.7.1 no-access
This describes a row in the diagnostic table.
               sfpDiagnosticValid 1.3.6.1.4.1.3373.1103.74.7.1.1 truthvalue read-only
if False, then the SFP data in this table is not valid. This will be set to False if the SFP module is not installed, or if the I/O card that contains the SFP is not installed or if the EEPROM check code is wrong. The data in the table should not be used unless this element is True.
               sfpLOSPinOut 1.3.6.1.4.1.3373.1103.74.7.1.2 truthvalue read-only
This contains the T/F state of the SFP LOS (output) pin. It is True if the SFP has detected Loss-Of-Signal. located at I2c address 0xa2, address: 110, mask 0x02
               sfpTxFaultPinOut 1.3.6.1.4.1.3373.1103.74.7.1.3 truthvalue read-only
This contains the T/F state of the SFP Tx Fault (output) pin. It is True if the SFP has detected a Tx fault condition. located at I2C address 0xa2, Byte 110, mask 0x04
               sfpRateSelectPinIn 1.3.6.1.4.1.3373.1103.74.7.1.4 truthvalue read-only
This contains the T/F state of the SFP RX Rate Select (input) pin. This function is not implemented on Finisar SFPs. located at I2C address 0xa2, Byte 110, mask 0x10
               sfpTxDisablePinIn 1.3.6.1.4.1.3373.1103.74.7.1.5 truthvalue read-only
This contains the T/F state of the SFP TX Disable (input) pin. located at I2C address 0xa2, Byte 110, mask 0x80
               sfpTemperature 1.3.6.1.4.1.3373.1103.74.7.1.6 temperature read-only
This contains the internal temperature of the SFP in tehnth of Celsius degrees. Range is from -128.0C to +128.0C, but is only valid from -40.0C to +125.0C with an accuracy of +/- 3C. Located at I2C address 0xa2, Bytes 96 & 97 (MSB, LSB)
               sfpVoltage 1.3.6.1.4.1.3373.1103.74.7.1.7 integer32 read-only
This contains the internally measured SFP supply voltage (Vcc). Units are in milliVolts (3210 = 3.21V). Range is 0 to 6.554V. Located at I2C address 0xa2, Bytes 98 & 99 (MSB, LSB)
               sfpTxBias 1.3.6.1.4.1.3373.1103.74.7.1.8 integer32 read-only
This contains the internally measured SFP TX laser bias current. Units are in microAmps, and range from 0 to 131000uA (131mA). Located at I2C address 0xa2, Bytes 100 & 101 (MSB, LSB)
               sfpTxPower 1.3.6.1.4.1.3373.1103.74.7.1.9 integer32 read-only
This contains the internally measured TX output power. Units are in uW (micro Watts), and range from 0 to 6554uW (6.535mW). This value is not valid if the transmitter is disabled. Located at I2C address 0xa2, Bytes 102 & 103 (MSB, LSB)
               sfpRxPower 1.3.6.1.4.1.3373.1103.74.7.1.10 integer32 read-only
This contains the internally measured RX optical power. Units are in uW (micro Watts), and range from 0 to 6554uW (6.535mW). Located at I2C address 0xa2, Bytes 104 & 105 (MSB, LSB)
               sfpInternalAlarms 1.3.6.1.4.1.3373.1103.74.7.1.11 bits read-only
This contains the state of the SFP internal alarm register. A bit is set for each alarm that is active. located at I2C address 0xa2, Byte 112 & 113 (MSB, LSB) mask 0xffc0 Bits: 'sfpIntAlarmVoltageHigh': 2, 'sfpIntAlarmTempHigh': 0, 'sfpIntAlarmRxPowerLow': 9, 'sfpIntAlarmTxPowerLow': 7, 'sfpIntAlarmVoltageLow': 3, 'sfpIntAlarmTxBiasHigh': 4, 'sfpIntAlarmTxBiasLow': 5, 'sfpIntAlarmTxPowerHigh': 6, 'sfpIntAlarmRxPowerHigh': 8, 'sfpIntAlarmTempLow': 1.
               sfpInternalWarnings 1.3.6.1.4.1.3373.1103.74.7.1.12 bits read-only
This contains the state of the SFP internal warning register. A bit is set for each warning that is active. located at I2C address 0xa2, Byte 116 & 117 (MSB, LSB) mask 0xffc0 Bits: 'sfpIntWarnRxPowerLow': 9, 'sfpIntWarnTempLow': 1, 'sfpIntWarnTxPowerLow': 7, 'sfpIntWarnVoltageLow': 3, 'sfpIntWarnTxBiasLow': 5, 'sfpIntWarnTxBiasHigh': 4, 'sfpIntWarnRxPowerHigh': 8, 'sfpIntWarnVoltageHigh': 2, 'sfpIntWarnTempHigh': 0, 'sfpIntWarnTxPowerHigh': 6.
       sfpAlarmTable 1.3.6.1.4.1.3373.1103.74.10 no-access
This table contains the SFP alarm and warning threshold values.
             sfpAlarmEntry 1.3.6.1.4.1.3373.1103.74.10.1 no-access
An entry into the Threshold table.
                 sfpPhysicalQuantity 1.3.6.1.4.1.3373.1103.74.10.1.1 physicalquantity read-only
Measured physical quantity. Units of temperature are tenth of Celsius degrres, units of Power supply voltage (Vcc) are microVolts, units of Tx laser bias current are microAmps (uA), units of Rx optical power are microWatts (uW), units of Tx output power are microWatts (uW).
                 sfpThresholdHighAlarm 1.3.6.1.4.1.3373.1103.74.10.1.2 integer32 read-only
A reading at or above this temperature will trigger a high measured physical quantity alarm.
                 sfpThresholdHighWarning 1.3.6.1.4.1.3373.1103.74.10.1.3 integer32 read-only
A reading at or above this temperature will trigger a high measured physical quantity warning.
                 sfpThresholdLowAlarm 1.3.6.1.4.1.3373.1103.74.10.1.4 integer32 read-only
A reading at or above this temperature will trigger a low measured physical quantity alarm.
                 sfpThresholdLowWarning 1.3.6.1.4.1.3373.1103.74.10.1.5 integer32 read-only
A reading at or above this temperature will trigger a low measured physical quantity warning.
                 sfpHighAlarm 1.3.6.1.4.1.3373.1103.74.10.1.6 alarmstatus read-only
Measured physical quantity has crossed sfpThresholdHighAlarm.
                 sfpHighWarningAlarm 1.3.6.1.4.1.3373.1103.74.10.1.7 alarmstatus read-only
Measured physical quantity has crossed sfpThresholdHighWarning.
                 sfpLowAlarm 1.3.6.1.4.1.3373.1103.74.10.1.8 alarmstatus read-only
Measured physical quantity has crossed sfpThresholdLowAlarm.
                 sfpLowWarningAlarm 1.3.6.1.4.1.3373.1103.74.10.1.9 alarmstatus read-only
Measured physical quantity has crossed sfpThresholdLowWarning.
       sfpHighAlarmSeverityCode 1.3.6.1.4.1.3373.1103.74.11 alarmseveritycode read-write
Defines the severity associated to the sfpHighAlarm and enables/disables the trap generation on status change event.
       sfpHighWarningAlarmSeverityCode 1.3.6.1.4.1.3373.1103.74.12 alarmseveritycode read-write
Defines the severity associated to the sfpHighWarningAlarm and enables/disables the trap generation on status change event.
       sfpLowAlarmSeverityCode 1.3.6.1.4.1.3373.1103.74.13 alarmseveritycode read-write
Defines the severity associated to the sfpLowAlarm and enables/disables the trap generation on status change event.
       sfpLowWarningAlarmSeverityCode 1.3.6.1.4.1.3373.1103.74.14 alarmseveritycode read-write
Defines the severity associated to the sfpLowWarningAlarm and enables/disables the trap generation on status change event.