SIAE-PMRXPWR-MIB: View SNMP OID List / Download MIB
VENDOR: SIAE MICROELETTRONICA S.P.A.
Home | MIB: SIAE-PMRXPWR-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
pmRxPwr | 1.3.6.1.4.1.3373.1103.12 |
Performance Monitoring on Received (RX) RF Power. |
||
pmRxPwrMibVersion | 1.3.6.1.4.1.3373.1103.12.1 | integer | read-only |
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01. |
pmRxPwrCounterTable | 1.3.6.1.4.1.3373.1103.12.2 | no-access |
Table with PmRxPwr records: one record for 1+0 configuration and two record for 1+1 configuration. |
|
1.3.6.1.4.1.3373.1103.12.2.1 | no-access |
PmRxPwrCounter record. |
||
pmRxPwrBranchId | 1.3.6.1.4.1.3373.1103.12.2.1.1 | integer32 | read-only |
This object identifies the Radio Branch |
pmRxPwrCounterBlockId | 1.3.6.1.4.1.3373.1103.12.2.1.2 | integer32 | read-only |
This object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 20 15 minutes counters N.16(The oldest 15 min. counters 4 hours before). |
pmRxPwrCounterBlockType | 1.3.6.1.4.1.3373.1103.12.2.1.3 | integer | read-only |
The type of the counter block. Enumeration: 'fifteenMin': 2, 'daily': 1. |
pmRxPwrCounterBlockStatus | 1.3.6.1.4.1.3373.1103.12.2.1.4 | integer | read-only |
Status of the block counter. Enumeration: 'dummy': 4, 'meaningfull': 2, 'lost': 5, 'restarted': 6, 'meaningless': 1, 'incomplete': 3. |
pmRxPwrCounterTimeStamp | 1.3.6.1.4.1.3373.1103.12.2.1.5 | unsigned32 | read-only |
The object is the time when the performance record is closed reported as the second number since 1-Gen-1970. |
pmRxPwrRlts1Counter | 1.3.6.1.4.1.3373.1103.12.2.1.6 | counter32 | read-only |
Number of seconds when the Received power is less than the threshold 1. |
pmRxPwrRlts2Counter | 1.3.6.1.4.1.3373.1103.12.2.1.7 | counter32 | read-only |
Number of seconds when the Received power is less than the threshold 2 |
pmRxPwrRlts3Counter | 1.3.6.1.4.1.3373.1103.12.2.1.8 | counter32 | read-only |
Number of seconds when the Received power is less than the threshold 3 |
pmRxPwrRlts4Counter | 1.3.6.1.4.1.3373.1103.12.2.1.9 | counter32 | read-only |
Number of seconds when the Received power is less than the threshold 4 |
pmRxPwrRlts5Counter | 1.3.6.1.4.1.3373.1103.12.2.1.10 | counter32 | read-only |
Number of seconds when the Received power is less than the threshold 5 |
pmRxPwrTMMax | 1.3.6.1.4.1.3373.1103.12.2.1.11 | integer32 | read-only |
Maximum Power Received Level Tide Mark. |
pmRxPwrTMMin | 1.3.6.1.4.1.3373.1103.12.2.1.12 | integer32 | read-only |
Minimum Power Received Level Tide Mark. |
pmRxPwrAverageRxLevel | 1.3.6.1.4.1.3373.1103.12.2.1.13 | integer32 | read-only |
Power Received Level (Average value) |
pmRxPwrTpClassTable | 1.3.6.1.4.1.3373.1103.12.3 | no-access |
Table with PmRxPwrTpClass records: one record for 1+0 configuration and two record for 1+1 configuration. |
|
1.3.6.1.4.1.3373.1103.12.3.1 | no-access |
PmRxPwrTpClass record. |
||
pmRxPwrTpClassBranchId | 1.3.6.1.4.1.3373.1103.12.3.1.1 | integer32 | read-only |
This object identifies the Radio Branch |
pmRxPwrTpClassStartStop | 1.3.6.1.4.1.3373.1103.12.3.1.2 | integer | read-only |
This object is used to start and to stop the Perfomance Monitoring counter evaluation. Enumeration: 'start': 1, 'stop': 2. |
pmRxPwrTpClassLabel | 1.3.6.1.4.1.3373.1103.12.3.1.3 | displaystring | read-only |
ASCII string used to identify the Tp class: pmRxPwrTpClassBranchId = 1 label = Radio 1 pmRxPwrTpClassBranchId = 2 label = Radio 2. |
pmRxPwrTpClassTimeStamp | 1.3.6.1.4.1.3373.1103.12.3.1.4 | unsigned32 | read-only |
The object is the time when the performance record is closed reported as the second number since 1/1/70. |
pmRxPwrTpClass15MRlts1Alarm | 1.3.6.1.4.1.3373.1103.12.3.1.5 | alarmstatus | read-only |
15 minutes Rlts1 threshold cross alarm with associated severity. |
pmRxPwrTpClass15MRlts2Alarm | 1.3.6.1.4.1.3373.1103.12.3.1.6 | alarmstatus | read-only |
15 minutes Rlts2 threshold cross alarm with associated severity. |
pmRxPwrTpClass15MRlts3Alarm | 1.3.6.1.4.1.3373.1103.12.3.1.7 | alarmstatus | read-only |
15 minutes Rlts3 threshold cross alarm with associated severity. |
pmRxPwrTpClass15MRlts4Alarm | 1.3.6.1.4.1.3373.1103.12.3.1.8 | alarmstatus | read-only |
15 minutes Rlts4 threshold cross alarm with associated severity. |
pmRxPwrTpClass15MRlts5Alarm | 1.3.6.1.4.1.3373.1103.12.3.1.9 | alarmstatus | read-only |
15 minutes Rlts5 threshold cross alarm with associated severity. |
pmRxPwrTpClass24HRlts1Alarm | 1.3.6.1.4.1.3373.1103.12.3.1.10 | alarmstatus | read-only |
Daily Rlts1 threshold cross alarm with associated severity. |
pmRxPwrTpClass24HRlts2Alarm | 1.3.6.1.4.1.3373.1103.12.3.1.11 | alarmstatus | read-only |
Daily Rlts2 threshold cross alarm with associated severity. |
pmRxPwrTpClass24HRlts3Alarm | 1.3.6.1.4.1.3373.1103.12.3.1.12 | alarmstatus | read-only |
Daily Rlts3 threshold cross alarm with associated severity. |
pmRxPwrTpClass24HRlts4Alarm | 1.3.6.1.4.1.3373.1103.12.3.1.13 | alarmstatus | read-only |
Daily Rlts4 threshold cross alarm with associated severity. |
pmRxPwrTpClass24HRlts5Alarm | 1.3.6.1.4.1.3373.1103.12.3.1.14 | alarmstatus | read-only |
Daily Rlts5 threshold cross alarm with associated severity. |
pmRxPwrTpClassRlt1Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.15 | integer | read-only |
Received Power Level Threshold 1 (dBm value); range -100 to -20 |
pmRxPwrTpClassRlt2Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.16 | integer | read-only |
Received Power Level Threshold 2 (dBm value); range -100 to -20 |
pmRxPwrTpClassRlt3Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.17 | integer | read-only |
Received Power Level Threshold 3 (dBm value); range -100 to -20 |
pmRxPwrTpClassRlt4Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.18 | integer | read-only |
Received Power Level Threshold 4 (dBm value); range -100 to -20 |
pmRxPwrTpClassRlt5Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.19 | integer | read-only |
Received Power Level Threshold 5 (dBm value); range -100 to -20 |
pmRxPwrTpClass15MRlts1Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.20 | integer32 | read-only |
Number of seconds within 15 minutes to set pmRxPwrTpClass15MRlts1Alarm (zero value disables the alarm). |
pmRxPwrTpClass15MRlts2Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.21 | integer32 | read-only |
Number of seconds within 15 minutes to set pmRxPwrTpClass15MRlts2Alarm (zero value disables the alarm). |
pmRxPwrTpClass15MRlts3Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.22 | integer32 | read-only |
Number of seconds within 15 minutes to set pmRxPwrTpClass15MRlts3Alarm (zero value disables the alarm). |
pmRxPwrTpClass15MRlts4Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.23 | integer32 | read-only |
Number of seconds within 15 minutes to set pmRxPwrTpClass15MRlts4Alarm (zero value disables the alarm). |
pmRxPwrTpClass15MRlts5Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.24 | integer32 | read-only |
Number of seconds within 15 minutes to set pmRxPwrTpClass15MRlts5Alarm (zero value disables the alarm). |
pmRxPwrTpClass24HRlts1Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.25 | integer32 | read-only |
Number of seconds within a day to set pmRxPwrTpClass24HRlts1Alarm (zero value disables the alarm). |
pmRxPwrTpClass24HRlts2Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.26 | integer32 | read-only |
Number of seconds within a day to set pmRxPwrTpClass24HRlts2Alarm (zero value disables the alarm). |
pmRxPwrTpClass24HRlts3Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.27 | integer32 | read-only |
Number of seconds within a day to set pmRxPwrTpClass24HRlts3Alarm (zero value disables the alarm). |
pmRxPwrTpClass24HRlts4Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.28 | integer32 | read-only |
Number of seconds within a day to set pmRxPwrTpClass24HRlts4Alarm (zero value disables the alarm). |
pmRxPwrTpClass24HRlts5Threshold | 1.3.6.1.4.1.3373.1103.12.3.1.29 | integer32 | read-only |
Number of seconds within a day to set pmRxPwrTpClass24HRlts5Alarm (zero value disables the alarm). |
pmRxPwrTpClassRowStatus | 1.3.6.1.4.1.3373.1103.12.3.1.30 | rowstatus | read-only |
Status of this row of pmRxPwrTpClass. |
pmRxPwrTpMaintTable | 1.3.6.1.4.1.3373.1103.12.4 | no-access |
Table with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmRxPwrTpClassTable |
|
1.3.6.1.4.1.3373.1103.12.4.1 | no-access |
PmG828 Termination Point Maintenance record. |
||
pmRxPwrTpMaintCounterClear | 1.3.6.1.4.1.3373.1103.12.4.1.1 | integer | read-write |
This object is used to clear the Perfomance Monitoring counters. Enumeration: 'notActive': 0, 'clear': 1. |
pmRxPwrTpMaintAlarmClear | 1.3.6.1.4.1.3373.1103.12.4.1.2 | integer | read-write |
This object is used to clear the Perfomance Monitoring threshold cross alarms. Enumeration: 'notActive': 0, 'clear': 1. |
pmRxPwrTpClass15MRltsAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.12.5 | alarmseveritycode | read-write |
Define the severity associated to the pmRxPwrTpClass15MRltsAlarm and enables/disables the trap generation on status change event. |
pmRxPwrTpClass24HRltsAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.12.6 | alarmseveritycode | read-write |
Define the severity associated to the pmRxPwrTpClass24HRltsAlarm and enables/disables the trap generation on status change event. |