SIAE-PMG828-MIB: View SNMP OID List / Download MIB
VENDOR: SIAE MICROELETTRONICA S.P.A.
Home | MIB: SIAE-PMG828-MIB | |||
---|---|---|---|---|
Download as: |
Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
pmG828 | 1.3.6.1.4.1.3373.1103.11 |
Perforfamce Monitoring according to ITU-T G.829 for Radio Link and E1 Tributaries |
||
pmG828MibVersion | 1.3.6.1.4.1.3373.1103.11.1 | integer | read-only |
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01. |
pmG828CounterTable | 1.3.6.1.4.1.3373.1103.11.2 | no-access |
Table with PmG828 records: one record for 1+0 configuration and two record for 1+1 configuration. |
|
1.3.6.1.4.1.3373.1103.11.2.1 | no-access |
PmG828Counter record. |
||
pmG828TPointId | 1.3.6.1.4.1.3373.1103.11.2.1.1 | integer32 | read-only |
This object identifies the Termination Point. |
pmG828CounterBlockId | 1.3.6.1.4.1.3373.1103.11.2.1.2 | integer32 | read-only |
This object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 20 15 minutes counters N.16(The oldest 15 min.counters 4 hours before). |
pmG828CounterBlockType | 1.3.6.1.4.1.3373.1103.11.2.1.3 | integer | read-only |
The type of the counter block. Enumeration: 'fifteenMin': 2, 'daily': 1. |
pmG828CounterBlockStatus | 1.3.6.1.4.1.3373.1103.11.2.1.4 | integer | read-only |
Status of the block counter. Enumeration: 'dummy': 4, 'meaningfull': 2, 'lost': 5, 'restarted': 6, 'meaningless': 1, 'incomplete': 3. |
pmG828CounterTimeStamp | 1.3.6.1.4.1.3373.1103.11.2.1.5 | unsigned32 | read-only |
The object is the time when the performance record is closed reported as the second number since 1-Gen-1970. |
pmG828BBECounter | 1.3.6.1.4.1.3373.1103.11.2.1.6 | counter32 | read-only |
G828 BBE counter. |
pmG828ESCounter | 1.3.6.1.4.1.3373.1103.11.2.1.7 | counter32 | read-only |
G828 Es counter. |
pmG828SESCounter | 1.3.6.1.4.1.3373.1103.11.2.1.8 | counter32 | read-only |
G828 SES counter. |
pmG828UASCounter | 1.3.6.1.4.1.3373.1103.11.2.1.9 | counter32 | read-only |
G828 UAS counter. |
pmG828SEPCounter | 1.3.6.1.4.1.3373.1103.11.2.1.10 | counter32 | read-only |
G828 SEP counter. |
pmG828TpClassTable | 1.3.6.1.4.1.3373.1103.11.3 | no-access |
Table with PmG828TpClass records: one record for 1+0 configuration and two record for 1+1 configuration. |
|
1.3.6.1.4.1.3373.1103.11.3.1 | no-access |
PmG828TpClass record. |
||
pmG828TpClassId | 1.3.6.1.4.1.3373.1103.11.3.1.1 | integer32 | read-only |
This object identifies the Termination Point. |
pmG828TpClassStartStop | 1.3.6.1.4.1.3373.1103.11.3.1.2 | integer | read-only |
This object is used to start and to stop the Perfomance Monitoring counter evaluation. Enumeration: 'start': 1, 'stop': 2. |
pmG828TpClassLabel | 1.3.6.1.4.1.3373.1103.11.3.1.3 | displaystring | read-only |
ASCII string used to identify the Tp class: for example: pmG828TpClassBranchId = 1 label = Radio 1 pmG828TpClassBranchId = 2 label = Radio 2 pmG828TpClassBranchId = 3 label = Radio(switched) pmG828TpClassBranchId = 4 label = Trib E1 line side pmG828TpClassBranchId = 5 label = Trib E1 radio side. |
pmG828TpClassTimeStamp | 1.3.6.1.4.1.3373.1103.11.3.1.4 | unsigned32 | read-only | |
pmG828TpClass15MEsAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.5 | alarmstatus | read-only |
15 minutes ES threshold cross alarm with associated severity. |
pmG828TpClass15MSesAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.6 | alarmstatus | read-only |
15 minutes SES threshold cross alarm with associated severity. |
pmG828TpClass15MSepAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.7 | alarmstatus | read-only |
15 minutes SEP threshold cross alarm with associated severity. |
pmG828TpClass24HEsAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.8 | alarmstatus | read-only |
Daily ES threshold cross alarm with associated severity. |
pmG828TpClass24HSesAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.9 | alarmstatus | read-only |
Daily SES threshold cross alarm with associated severity. |
pmG828TpClass24HSepAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.10 | alarmstatus | read-only |
Daily SEP threshold cross alarm with associated severity. |
pmG828TpClassUasAlarm | 1.3.6.1.4.1.3373.1103.11.3.1.11 | alarmstatus | read-only |
UAS alarm with associated severity. |
pmG828TpClass15MEsThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.12 | integer32 | read-only |
Number of ES within 15 minutes to set pmG828TpClass15MEsAlarm (zero value disables the alarm). |
pmG828TpClass15MSesThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.13 | integer32 | read-only |
Number of SES within 15 minutes to set pmG828TpClass15MSesAlarm (zero value disables the alarm). |
pmG828TpClass15MSepThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.14 | integer32 | read-only |
Number of SEP within 15 minutes to set pmG828TpClass15MSepAlarm (zero value disables the alarm). |
pmG828TpClass24HEsThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.15 | integer32 | read-only |
Number of ES within one day to set pmG828TpClass24HEsAlarm (zero value disables the alarm). |
pmG828TpClass24HSesThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.16 | integer32 | read-only |
Number of SES within one day to set pmG828TpClass24HSesAlarm (zero value disables the alarm). |
pmG828TpClass24HSepThreshold | 1.3.6.1.4.1.3373.1103.11.3.1.17 | integer32 | read-only |
Number of SEP within one day to set pmG828TpClass24HSepAlarm (zero value disables the alarm). |
pmG828TpClassRowStatus | 1.3.6.1.4.1.3373.1103.11.3.1.18 | rowstatus | read-only |
Status of this row of pmRxPwrTpClass. |
pmG828TpMaintTable | 1.3.6.1.4.1.3373.1103.11.4 | no-access |
Table with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmG828TpClassTable |
|
1.3.6.1.4.1.3373.1103.11.4.1 | no-access |
PmG828 Termination Point Maintenance record. |
||
pmG828TpMaintCounterClear | 1.3.6.1.4.1.3373.1103.11.4.1.1 | integer | read-write |
This object is used to clear the Perfomance Monitoring counters. Enumeration: 'notActive': 0, 'clear': 1. |
pmG828TpMaintAlarmClear | 1.3.6.1.4.1.3373.1103.11.4.1.2 | integer | read-write |
This object is used to clear the Perfomance Monitoring threshold cross alarms. Enumeration: 'notActive': 0, 'clear': 1. |
pmG828NSesSetUAS | 1.3.6.1.4.1.3373.1103.11.5 | integer32 | read-write |
Number of SES (according G.828) to set UAS. |
pmG828NSesResetUAS | 1.3.6.1.4.1.3373.1103.11.6 | integer32 | read-write |
Number of seconds whitout errors (according G.828) to reset UAS. |
pmG828TpClass15MEsAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.7 | alarmseveritycode | read-write |
Defines the severity associated to the pmG828TpClass15MEsAlarm and enables/disables the trap generation on status change event. |
pmG828TpClass15MSesAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.8 | alarmseveritycode | read-write |
Define the severity associated to the pmG828TpClass15MSesAlarm and enables/disables the trap generation on status change event. |
pmG828TpClass24HEsAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.9 | alarmseveritycode | read-write |
Define the severity associated to the pmG828TpClass15MEsAlarm and enables/disables the trap generation on status change event. |
pmG828TpClass24HSesAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.10 | alarmseveritycode | read-write |
Define the severity associated to the pmG828TpClass15MSesAlarm and enables/disables the trap generation on status change event. |
pmG828TpClassUASAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.11 | alarmseveritycode | read-write |
Define the severity associated to the pmG828TpClassUASAlarm and enables/disables the trap generation on status change event. |
pmG828TpClass15MSepAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.12 | alarmseveritycode | read-write |
Define the severity associated to the pmG828TpClass15MSepAlarm and enables/disables the trap generation on status change event. |
pmG828TpClass24HSepAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.11.13 | alarmseveritycode | read-write |
Define the severity associated to the pmG828TpClass24HSepAlarm and enables/disables the trap generation on status change event. |