SIAE-PMG828-MIB: View SNMP OID List / Download MIB

VENDOR: SIAE MICROELETTRONICA S.P.A.


 Home MIB: SIAE-PMG828-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 pmG828 1.3.6.1.4.1.3373.1103.11
Perforfamce Monitoring according to ITU-T G.829 for Radio Link and E1 Tributaries
       pmG828MibVersion 1.3.6.1.4.1.3373.1103.11.1 integer read-only
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.
       pmG828CounterTable 1.3.6.1.4.1.3373.1103.11.2 no-access
Table with PmG828 records: one record for 1+0 configuration and two record for 1+1 configuration.
           pmG828CounterRecord 1.3.6.1.4.1.3373.1103.11.2.1 no-access
PmG828Counter record.
               pmG828TPointId 1.3.6.1.4.1.3373.1103.11.2.1.1 integer32 read-only
This object identifies the Termination Point.
               pmG828CounterBlockId 1.3.6.1.4.1.3373.1103.11.2.1.2 integer32 read-only
This object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 20 15 minutes counters N.16(The oldest 15 min.counters 4 hours before).
               pmG828CounterBlockType 1.3.6.1.4.1.3373.1103.11.2.1.3 integer read-only
The type of the counter block. Enumeration: 'fifteenMin': 2, 'daily': 1.
               pmG828CounterBlockStatus 1.3.6.1.4.1.3373.1103.11.2.1.4 integer read-only
Status of the block counter. Enumeration: 'dummy': 4, 'meaningfull': 2, 'lost': 5, 'restarted': 6, 'meaningless': 1, 'incomplete': 3.
               pmG828CounterTimeStamp 1.3.6.1.4.1.3373.1103.11.2.1.5 unsigned32 read-only
The object is the time when the performance record is closed reported as the second number since 1-Gen-1970.
               pmG828BBECounter 1.3.6.1.4.1.3373.1103.11.2.1.6 counter32 read-only
G828 BBE counter.
               pmG828ESCounter 1.3.6.1.4.1.3373.1103.11.2.1.7 counter32 read-only
G828 Es counter.
               pmG828SESCounter 1.3.6.1.4.1.3373.1103.11.2.1.8 counter32 read-only
G828 SES counter.
               pmG828UASCounter 1.3.6.1.4.1.3373.1103.11.2.1.9 counter32 read-only
G828 UAS counter.
               pmG828SEPCounter 1.3.6.1.4.1.3373.1103.11.2.1.10 counter32 read-only
G828 SEP counter.
       pmG828TpClassTable 1.3.6.1.4.1.3373.1103.11.3 no-access
Table with PmG828TpClass records: one record for 1+0 configuration and two record for 1+1 configuration.
           pmG828TpClassRecord 1.3.6.1.4.1.3373.1103.11.3.1 no-access
PmG828TpClass record.
               pmG828TpClassId 1.3.6.1.4.1.3373.1103.11.3.1.1 integer32 read-only
This object identifies the Termination Point.
               pmG828TpClassStartStop 1.3.6.1.4.1.3373.1103.11.3.1.2 integer read-only
This object is used to start and to stop the Perfomance Monitoring counter evaluation. Enumeration: 'start': 1, 'stop': 2.
               pmG828TpClassLabel 1.3.6.1.4.1.3373.1103.11.3.1.3 displaystring read-only
ASCII string used to identify the Tp class: for example: pmG828TpClassBranchId = 1 label = Radio 1 pmG828TpClassBranchId = 2 label = Radio 2 pmG828TpClassBranchId = 3 label = Radio(switched) pmG828TpClassBranchId = 4 label = Trib E1 line side pmG828TpClassBranchId = 5 label = Trib E1 radio side.
               pmG828TpClassTimeStamp 1.3.6.1.4.1.3373.1103.11.3.1.4 unsigned32 read-only
               pmG828TpClass15MEsAlarm 1.3.6.1.4.1.3373.1103.11.3.1.5 alarmstatus read-only
15 minutes ES threshold cross alarm with associated severity.
               pmG828TpClass15MSesAlarm 1.3.6.1.4.1.3373.1103.11.3.1.6 alarmstatus read-only
15 minutes SES threshold cross alarm with associated severity.
               pmG828TpClass15MSepAlarm 1.3.6.1.4.1.3373.1103.11.3.1.7 alarmstatus read-only
15 minutes SEP threshold cross alarm with associated severity.
               pmG828TpClass24HEsAlarm 1.3.6.1.4.1.3373.1103.11.3.1.8 alarmstatus read-only
Daily ES threshold cross alarm with associated severity.
               pmG828TpClass24HSesAlarm 1.3.6.1.4.1.3373.1103.11.3.1.9 alarmstatus read-only
Daily SES threshold cross alarm with associated severity.
               pmG828TpClass24HSepAlarm 1.3.6.1.4.1.3373.1103.11.3.1.10 alarmstatus read-only
Daily SEP threshold cross alarm with associated severity.
               pmG828TpClassUasAlarm 1.3.6.1.4.1.3373.1103.11.3.1.11 alarmstatus read-only
UAS alarm with associated severity.
               pmG828TpClass15MEsThreshold 1.3.6.1.4.1.3373.1103.11.3.1.12 integer32 read-only
Number of ES within 15 minutes to set pmG828TpClass15MEsAlarm (zero value disables the alarm).
               pmG828TpClass15MSesThreshold 1.3.6.1.4.1.3373.1103.11.3.1.13 integer32 read-only
Number of SES within 15 minutes to set pmG828TpClass15MSesAlarm (zero value disables the alarm).
               pmG828TpClass15MSepThreshold 1.3.6.1.4.1.3373.1103.11.3.1.14 integer32 read-only
Number of SEP within 15 minutes to set pmG828TpClass15MSepAlarm (zero value disables the alarm).
               pmG828TpClass24HEsThreshold 1.3.6.1.4.1.3373.1103.11.3.1.15 integer32 read-only
Number of ES within one day to set pmG828TpClass24HEsAlarm (zero value disables the alarm).
               pmG828TpClass24HSesThreshold 1.3.6.1.4.1.3373.1103.11.3.1.16 integer32 read-only
Number of SES within one day to set pmG828TpClass24HSesAlarm (zero value disables the alarm).
               pmG828TpClass24HSepThreshold 1.3.6.1.4.1.3373.1103.11.3.1.17 integer32 read-only
Number of SEP within one day to set pmG828TpClass24HSepAlarm (zero value disables the alarm).
               pmG828TpClassRowStatus 1.3.6.1.4.1.3373.1103.11.3.1.18 rowstatus read-only
Status of this row of pmRxPwrTpClass.
       pmG828TpMaintTable 1.3.6.1.4.1.3373.1103.11.4 no-access
Table with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmG828TpClassTable
           pmG828TpMaintRecord 1.3.6.1.4.1.3373.1103.11.4.1 no-access
PmG828 Termination Point Maintenance record.
               pmG828TpMaintCounterClear 1.3.6.1.4.1.3373.1103.11.4.1.1 integer read-write
This object is used to clear the Perfomance Monitoring counters. Enumeration: 'notActive': 0, 'clear': 1.
               pmG828TpMaintAlarmClear 1.3.6.1.4.1.3373.1103.11.4.1.2 integer read-write
This object is used to clear the Perfomance Monitoring threshold cross alarms. Enumeration: 'notActive': 0, 'clear': 1.
       pmG828NSesSetUAS 1.3.6.1.4.1.3373.1103.11.5 integer32 read-write
Number of SES (according G.828) to set UAS.
       pmG828NSesResetUAS 1.3.6.1.4.1.3373.1103.11.6 integer32 read-write
Number of seconds whitout errors (according G.828) to reset UAS.
       pmG828TpClass15MEsAlarmSeverityCode 1.3.6.1.4.1.3373.1103.11.7 alarmseveritycode read-write
Defines the severity associated to the pmG828TpClass15MEsAlarm and enables/disables the trap generation on status change event.
       pmG828TpClass15MSesAlarmSeverityCode 1.3.6.1.4.1.3373.1103.11.8 alarmseveritycode read-write
Define the severity associated to the pmG828TpClass15MSesAlarm and enables/disables the trap generation on status change event.
       pmG828TpClass24HEsAlarmSeverityCode 1.3.6.1.4.1.3373.1103.11.9 alarmseveritycode read-write
Define the severity associated to the pmG828TpClass15MEsAlarm and enables/disables the trap generation on status change event.
       pmG828TpClass24HSesAlarmSeverityCode 1.3.6.1.4.1.3373.1103.11.10 alarmseveritycode read-write
Define the severity associated to the pmG828TpClass15MSesAlarm and enables/disables the trap generation on status change event.
       pmG828TpClassUASAlarmSeverityCode 1.3.6.1.4.1.3373.1103.11.11 alarmseveritycode read-write
Define the severity associated to the pmG828TpClassUASAlarm and enables/disables the trap generation on status change event.
       pmG828TpClass15MSepAlarmSeverityCode 1.3.6.1.4.1.3373.1103.11.12 alarmseveritycode read-write
Define the severity associated to the pmG828TpClass15MSepAlarm and enables/disables the trap generation on status change event.
       pmG828TpClass24HSepAlarmSeverityCode 1.3.6.1.4.1.3373.1103.11.13 alarmseveritycode read-write
Define the severity associated to the pmG828TpClass24HSepAlarm and enables/disables the trap generation on status change event.