SIAE-CARRIER-AGGRL1-MIB: View SNMP OID List / Download MIB

VENDOR: SIAE MICROELETTRONICA S.P.A.


 Home MIB: SIAE-CARRIER-AGGRL1-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 carrierAggr 1.3.6.1.4.1.3373.1103.104
Carrier hybrid aggregation management for SIAE equipments.
         carrierAggrMibVersion 1.3.6.1.4.1.3373.1103.104.1 integer read-only
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.
         carrierAggrSensorTable 1.3.6.1.4.1.3373.1103.104.2 no-access
Table with Radio(s) interface(s) that can be associated to an entry of carrierAggrActuatorTable.
             carrierAggrSensorEntry 1.3.6.1.4.1.3373.1103.104.2.1 no-access
A row in the carrierAggrSensorTable.
                 carrierAggrSensorIndex 1.3.6.1.4.1.3373.1103.104.2.1.1 integer read-only
This object identifies the index of carrierAggrSensorTable.
                 carrierAggrSensorRowstatus 1.3.6.1.4.1.3373.1103.104.2.1.2 rowstatus read-only
The status of this sensor entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value: SensorIfIndex must be set to a valid ifIndex number. Otherwise, the error inconsistentValue is returned on the attempt to set active this row. When this object is set to notInService changes may be made to carrierAggrSensorIfIndex. Other objects can be changed when carrierAggrSensorRowStatus is set to active. A sensor can not be deleted if there is any Actuator (see table carrierAggrActuatorTable) associated with it.
                 carrierAggrSensorAdminStatus 1.3.6.1.4.1.3373.1103.104.2.1.3 integer read-only
Administative status of the sensor. The value down(1) turns off all actuators associated with this sensor. Enumeration: 'down': 1, 'up': 2.
                 carrierAggrSensorIfIndex 1.3.6.1.4.1.3373.1103.104.2.1.4 interfaceindexorzero read-only
This object accepts a greater than zero value to identify an interface in ifTable. Some parameters of the radio associated to this interface is monitored and a notification is sent to all connected actuators.
                 carrierAggrSensorHitlessCapability 1.3.6.1.4.1.3373.1103.104.2.1.5 bits read-only
This capability is related to HITLESS Behaviour carrierAggrSensorHitlessBehaviour. Bits: 'hitlessAvailable': 0.
                 carrierAggrSensorHitlessBehaviour 1.3.6.1.4.1.3373.1103.104.2.1.6 integer read-only
The hitless behaviour. When enabled, data related to the current ACM zone is notified to an external N.E. aggregator, so it can dynamically exclude/include the data-flow without loss of frames. It can be enabled only if carrierAggrSensorHitlessCapability is available Enumeration: 'enable': 2, 'disable': 1.
                 carrierAggrSensorHitlessMode 1.3.6.1.4.1.3373.1103.104.2.1.7 integer read-only
The policy to select the hitless profile (i.e. the lowest one under which a N.E. aggregator excludes the carrier from an existing aggregation). auto(1): Tx Lower Profile + 1 is selected; manual(2): the value set in carrierAggrSensorHitlessProfile is selected. Enumeration: 'auto': 1, 'manual': 2.
                 carrierAggrSensorHitlessProfile 1.3.6.1.4.1.3373.1103.104.2.1.8 integer read-only
The hitless profile in case of carrierHyAggrHitlessBehaviour set as enabled and carrierHyAggrHitlessMode set as manual.
                 carrierAggrSensorHitlessStatus 1.3.6.1.4.1.3373.1103.104.2.1.9 integer read-only
The working zone of the radio link. Enumeration: 'hitlessZone': 2, 'badZone': 3, 'goodZone': 1.
         carrierAggrActuatorTable 1.3.6.1.4.1.3373.1103.104.3 no-access
Table with Lan(s) interface that can be associated to an entry of carrierAggrSensorTable.
             carrierAggrActuatorEntry 1.3.6.1.4.1.3373.1103.104.3.1 no-access
A row in the carrierAggrActuatorTable.
                 carrierAggrActuatorIndex 1.3.6.1.4.1.3373.1103.104.3.1.1 integer read-only
This object identifies the carrier aggr Actuator inside the Network Element.
                 carrierAggrActuatorRowStatus 1.3.6.1.4.1.3373.1103.104.3.1.2 rowstatus read-only
The status of this entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value: carrierAggrActuatorIfIndex must be set to a valid ifIndex number and carrierAggrActuatorSensorIndex must be set to a valid sensor, Otherwise, the error inconsistentValue is returned on the attempt to set active this row. When set to notInService changes may be made to carrierAggrActuatorIfIndex and carrierAggrActuatorSensorIndex. Other objects can be changed when carrierAggrActuatorRowStatus is set to active.
                 carrierAggrActuatorAdminStatus 1.3.6.1.4.1.3373.1103.104.3.1.3 integer read-only
Administative status of the actuator. The value down(1) turns it off. Other actuators associated with the same sensor remain active. Enumeration: 'down': 1, 'up': 2.
                 carrierAggrActuatorIfIndex 1.3.6.1.4.1.3373.1103.104.3.1.4 interfaceindexorzero read-only
This object accepts a greater than zero value to identify an interface in ifTable. The notify received from the connected sensor is forwarded to the remote aggregator to signal some anomalies on this aggregated flow.
                 carrierAggrActuatorSensorIndex 1.3.6.1.4.1.3373.1103.104.3.1.5 integer32 read-only
This object connects this actuator to a sensor.
                 carrierAggrActuatorConcIpAddr 1.3.6.1.4.1.3373.1103.104.3.1.6 ipaddress read-only
This object is used to contain the Ip address of the equipment connected with this Lan (the concatenator unit)