Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
shePhysical | 1.3.6.1.4.1.231.7.1.2.1.1 |
The MIB module for representing multiple logical entities for the SHE Equipment management. |
||
shePhysContainerObjects | 1.3.6.1.4.1.231.7.1.2.1.1.1 | |||
shePhysContainerTable | 1.3.6.1.4.1.231.7.1.2.1.1.1.1 | no-access |
The container/slot table. |
|
1.3.6.1.4.1.231.7.1.2.1.1.1.1.1 | no-access |
Entry of the container table. The entries represent the slots of a SHE shelf |
||
shePhysContainerAccCardTypes | 1.3.6.1.4.1.231.7.1.2.1.1.1.1.1.1 | octet string | read-only |
This attribute identifies the types of plug-in units to be accepted by this slot. The strings are separated by newline characters. That means CR LF. Valid strings are: emptyCardType Central cards (support depend on NE release and used shelf): CXUGE:4E:E CXUCGE:4E:E CXUB1GE:4E:E CXUB2GE:4:E CXUC2GE:4:E CXUB3GE:4:E CXUB21GE:4:E CXUG1B:2O:4E:E (>=3.7M) DSL IU card's (support depend on used NE release): IUSHDSL:48S:E IUSHDSL:48B:E IUADSL:48P:E IUADSL:72A:E IUADSL:72B:E (obsolete) IUADSL:72P:IFX IUADSL:72I:IFX IUADSL:72AI:WC IUADSL:72AJ:WC IUVDSL:24D:IFX IUVDSL:24D2:IFX IUADSL:72A:CG IUADSL:72B:CG IUVDSL:24P:E IUVDSL:48P:E IUVDSL:48I:E (obsolete) IUADSL:72A:CGH IUADSL:72B:CGH IUADSL:72J:CGH IUSHDSL:48E:E IUSHDSL:48E:8Q:E (>=R2.8 maintenance) IUVDSL:48I2:E (>=R2.8) IUVDSL:48P2:E (>=R2.8) IUSHDSL:48E:ME:E (>=R3.7M) IUADSL:72B:M:CG (>=R3.7M) IUADSL:72B:ME:CG (>=R3.7M) IUADSL:72J:ME:CG (>=R3.7M) IUVDSL:48I3:M:E (>=R3.7M) IUVDSL:48I3:ME:E (>=R3.7M) IUVDSL:48J3:ME:E (>=R3.7M) Subtending card (with R3.7M also used as UNI card): IU1GE:10O:SYN:E VoIP-Cards (only supported if NE support VoIP at all): VPLU-S72-POTS:E IU:32I4:E IU:32I2:E VPLU:72P:E VPLU:72P1:E (>=R2.8M) VPLU:72P2:E (>=R2.8M) Powermodules (support depend on NE release and used shelf): PM1:E PM2:E PM3:A PM:UPL:E PM:UPL:R:E PM:UPL:A PM1:R:E PM1:R:A PM:R:A Powermodules for new shelftypes 2. generation -> 2G (>= R2.8 maintenance): PM:UPL:2G:E PM:UPL:2G:A PM1:R:2G:E PM:R:2G:E PM:R:2G:A PM:ONU:2G:E Boards for hiX5622 R1.0: (obsolete because release was canceled) CXUMGE:4:E SBXDSL:16P:E SBXDSL:16:E Board for hiX5608 (MiniIPD): HIX5608:E |
shePhysContainerSlotStatus | 1.3.6.1.4.1.231.7.1.2.1.1.1.1.1.4 | shephysslotstatustype | read-only |
Indicates whether a slot is empty or used. |
shePhysContainerConfiguredCardType | 1.3.6.1.4.1.231.7.1.2.1.1.1.1.1.5 | displaystring | read-only |
This attribute identifies the card type configured for this slot. Valid strings for card types are according to content of shePhysContainerAccCardTypes. |
shePhysContainerPluggedCardType | 1.3.6.1.4.1.231.7.1.2.1.1.1.1.1.6 | displaystring | read-only |
This attribute identifies the card type plugged for this slot. Valid strings for card types are according to content of shePhysContainerAccCardTypes. |
shePhysCardObjects | 1.3.6.1.4.1.231.7.1.2.1.1.2 | |||
shePhysCardTable | 1.3.6.1.4.1.231.7.1.2.1.1.2.1 | no-access |
Table containing the plug-in unit entries. |
|
1.3.6.1.4.1.231.7.1.2.1.1.2.1.1 | no-access |
Entry of shePhysCardTable. Each entry is used to represent a card independently whether it is present or not (feature offline configuration). Cards can be created either by auto-configuration (plug-in) or by user command. Notifications : shePhysStateChangeOper. shePhysStateChangeAdmin. shePhysCardCreated. shePhysCardDeleted. Alarm traps when a fault has been detected or cleared. |
||
shePhysCardAdminState | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.1 | shephyscardadminstatetype | read-only |
This attribute shows the administrative state of the plugin unit. In the transition from lock to unlock the plug-in unit is diagnosed. Default is notEquipped except for controller cards. The AdminState of controller cards is always unlocked. Planned is very similar to the locked state. Planned is used for configuration of cards without having a card equipped. A correct card being plugged leads to an auto-configuration of the card: the AdminState changes automatically from planned to unlocked. |
shePhysCardAvailState | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.2 | shephysavailabilitystatetype | read-only |
The availability state of a card. |
shePhysCardOperState | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.3 | shephyscardoperstatetype | read-only |
The operational state of a card. |
shePhysCardProtCapability | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.4 | shephysprotectioncapabilitytype | read-only |
The protection modes the card can work: -bit0=1: Card can work as standalone card. -bit1=1: Card can work as standby card. |
shePhysCardProtMode | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.5 | shephysprotectionmodetype | read-only |
The redundancy mode the card is running. -standaloneCard: The card works as standalone board. No redundancy is supported. -protectionCard: The card works in redundancy mode. |
shePhysCardProtDefaultRole | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.6 | shephysdefaultroletype | read-only |
Defines the default role of the card (e.g. after power on) if more than one card which belong to the same protection group are become availible at the same time. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard. -working: The card becomes the active card by default. -protecting: The card becomes the standby card by default. |
shePhysCardProtDynamicRole | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.7 | shephysdynamicroletype | read-only |
The dynamic role of card. Note, this attribute is only valid if shePhysCardProtMode = protectionCard. -active: The card is the active card. -standby: The card is the standby card. -notDefined: If there is no card plugged, it is not possible to say which card will become the active or standby card. |
shePhysCardProtGroupId | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.8 | integer | read-only |
The ID of protection group this card belongs to. Cards with the same Id can protect each other. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard. |
shePhysCardProtState | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.9 | shephysprotstate | read-only |
The current state of the protection: -unknown If the dynamic role of the cards which belong to a protection group is not set yet, there is no information about the protection state available. -active_noRedundancy: The card is the active card but is not protected by a standby card. -active_protected: The card is the active card is is protected by a standby card. -active_degraded: The card is the active card but not all functionality is protected by the standby card. -standby_notPresent: The card is the standby card but it is not available. -standby_booting: The card is the standby card but is still booting. -standby_protecting: The card is the standby card and protects the active card. -standby_degraded: The card is the standby card but can not take over all functionality of the current active board. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard. |
shePhysCardAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.10 | shealarmsevprofileindex | read-only |
It is a pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1. |
shePhysCardUpgradeState | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.11 | shephysupgradestatetype | read-only |
Informs about the state of the SW upgrade task during loading and the result at the end of loading the current plug-in unit. NOTE: The parameter is set to obsolete state with R3.7M. Also former releases does not report a valid information on this parameter. Valid informations about SW upgrade could only be retrieved via sheSystemSwMaintenanceTaskTable. |
shePhysCardSwRunningLoad | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.12 | octet string | read-only |
Informs about the currently running load. |
shePhysCardSwStoredLoad | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.13 | octet string | read-only |
Informs about the currently stored load. |
shePhysCardTemperatureCurrent | 1.3.6.1.4.1.231.7.1.2.1.1.2.1.1.14 | integer | read-only |
Current temperature of a card - 255 means unknown value. |
shePhysCardControl | 1.3.6.1.4.1.231.7.1.2.1.1.2.2 | |||
shePhysCardControlRequest | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.1 | shephyscardcontrolrequesttype | read-write |
The card commands : changeAdminState: changes the shePhysCardAdminState of a card. AdminState of controller cards cannot be changed. changeAlarmSeverityProfile: changes the shePhysCardAlarmSeverityIndex of a card. This is the pointer to a alarm severity profile. createCard: creates plugin units. Acceptable in state NotEquipped and when object does not exist. The AdminState after creation, possible values are Planned or Locked, is specified as command parameter. The command is not accepted for CXUs. These HW objects are automatically created. The acceptable CardTypes are specified in the slot attribute shePhysContainerAccCardTypes. The content of this attribute changes after the creation to values allowed for the convert command. deleteCard: deletes a card. Acceptable only in state Planned/Locked. The command is not accepted for CXUs. CXUs are automatically deleted when board redundancy is disabled. The AdminState changes to NotEquipped. convertCard: converts the type of card. Acceptable only within the same card group, e.g. ADSL to ADSL according to content of types listed in shePhysContainerAccCardTypes. convertCard allowed in state Planned/Locked. Notifications: shePhysCardControlResult when a command has finished. reset commands: resetSystem: reset of system (all cards) and activates loads after SW download. The main card will perform a restart. resetSystemWithDefaultConf : restart with default configuration is performed. resetCard: after SW download to activate the new load of a specific card. resetCardAllOfType: after SW download of cards of the same type to activate the new load. Notifications : shePhysCardReset at beginning of reset. shePhysCardResetEnd at end of reset. shePhysCardControlResult for reset of CXU in case of a failure occured after the reset has been accepted. changeAlarmSeverityProfile: the alarm severity profile is changed for a specific card. THIS REQUEST WILL NOT LONGER BE SUPPORTED BY NE R2.5: setTemperatureThreshold: configure the temperature threshold which is used. When temperature reaches the threshold, alarm is turned on. |
shePhysCardControlStatus | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.2 | shecontrolstatustype | read-only |
The status of a user command. |
shePhysCardControlPhysicalName | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.3 | snmpadminstring | read-write |
A valid string for a card. Identifies the type of card which should be created. Default is \0. |
shePhysCardControlContainedInIndex | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.4 | physicalindex | read-write |
The entPhysicalIndex of the slot which contains the card. |
shePhysCardControlTimer | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.5 | unsigned32 | read-only |
The maximum wait time for the manager for a long running user command. |
shePhysCardControlReqResult | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.6 | shephyscardcontrolrequestresulttype | read-only |
The result of the last user command. |
shePhysCardControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.7 | unsigned32 | read-only |
The time stamp of the last command (end of command). |
shePhysCardControlAdminStateChange | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.8 | shephysadminstatechangetype | read-write |
Selects the desired adminstrative state. |
shePhysCardControlAdminStateCreate | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.9 | shephysadminstatecreatetype | read-write |
Selects the desired adminstrative state in user command createCard. |
shePhysCardControlTemperatureThreshold | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.10 | integer | read-write |
The temperature threshold for all cards. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5. |
shePhysCardControlEntPhysicalIndex | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.13 | physicalindex | read-write |
The entPhysicalIndex of the plugin unit which should get the reset. |
shePhysCardControlAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.1.1.2.2.14 | shealarmsevprofileindex | read-write |
The new AlarmSeverityIndex of the alarm severity profile assigned to the card. |
sheTemperatureObjects | 1.3.6.1.4.1.231.7.1.2.1.1.2.3 | |||
shePhysCardTemperaturePowerDownOn | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.1 | integer | read-only |
Temperature threshold for generation of shePhysCardTemperaturePowerDown alarm for line cards. IU will start now with action to reduce power consumption. |
shePhysCardTemperaturePowerDownOff | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.2 | integer | read-only |
Temperature threshold for clearing of shePhysCardOverTemperatureReset alarm for the line cards. |
shePhysCardOverTemperatureResetOn | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.3 | integer | read-only |
Temperature threshold for the generation of the shePhysCardOverTemperatureReset alarm for line cards. CXU has forced IU tp reset state, to prevend from further damages. |
shePhysCardOverTemperatureResetOff | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.4 | integer | read-only |
Temperature threshold for the clearing the shePhysCardOverTemperatureReset alarm for line cards. |
shePhysCardTemperatureThreshold | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.5 | integer32 | read-only |
THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5. Temperature threshold for all cards of shePhysCardOverTemperatureThreshold. |
shePhysCardTemperatureWarningOn | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.6 | integer | read-only |
Temperature threshold for generation of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions. |
shePhysCardTemperatureWarningOff | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.7 | integer | read-only |
Temperature threshold for clearing of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions. |
sheTemperatureControlObjects | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10 | |||
shePhysCardTemperatureControlRequest | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.1 | shephyscontrolrequesttype | read-write |
The card commands : changeTemperatureWarningThreshold: changes the shePhysCardTemperatureWarningThreshold's. |
shePhysCardTemperatureControlStatus | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.2 | shecontrolstatustype | read-only |
The status of a user command. |
shePhysCardTemperatureControlTimer | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.3 | unsigned32 | read-only |
The maximum wait time for the manager for a long running user command. |
shePhysCardTemperatureControlReqResult | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.4 | shephyscardcontrolrequestresulttype | read-only |
The result of the last user command. |
shePhysCardTemperatureControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.5 | unsigned32 | read-only |
The time stamp of the last command (end of command). |
shePhysCardTemperatureControlWarningOn | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.6 | integer | read-write |
Temperature threshold for generation of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions. |
shePhysCardTemperatureControlWarningOff | 1.3.6.1.4.1.231.7.1.2.1.1.2.3.10.7 | integer | read-write |
Temperature threshold for clearing of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions. |
shePhysPortObjects | 1.3.6.1.4.1.231.7.1.2.1.1.3 | |||
shePhysPortTable | 1.3.6.1.4.1.231.7.1.2.1.1.3.1 | no-access |
The port table extension of the IfTable. Provides the mapping information concerning port and card the port is contained and the alarm severity profile. |
|
1.3.6.1.4.1.231.7.1.2.1.1.3.1.1 | no-access |
Entry of the port table. Represents a physical interface (a port). |
||
shePhysPortEntPhysicalIndex | 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.1 | physicalindex | read-only |
The entPhysical index of the card this port is contained in. |
shePhysPortId | 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.2 | integer | read-only |
The port number/port ID related to the card this port is contained in. |
shePhysPortAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.3 | shealarmsevprofileindex | read-only |
A pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1. |
shePhysPortUserLabel | 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.4 | octet string | read-only |
Port specific ASCII identification. This string is only used by the ACI to identifying a physical UserPort. The data is stored in NE but has no further meaning for the NE himself. |
shePhysPortAdminStateLastChangeTime | 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.5 | unsigned32 | read-only |
The timestamp when this port last times changes adminstate. New parameter with SHE R2.8 maintenance. |
shePhysPortOperStateUpLastChangeTime | 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.6 | unsigned32 | read-only |
The timestamp when this port last times reaches operstate UP. New parameter with SHE R2.8 maintenance. |
shePhysPortOperStateDownLastChangeTime | 1.3.6.1.4.1.231.7.1.2.1.1.3.1.1.7 | unsigned32 | read-only |
The timestamp when this port last times reaches operstate DOWN. New parameter with SHE R2.8 maintenance. |
shePhysPortControl | 1.3.6.1.4.1.231.7.1.2.1.1.3.2 | |||
shePhysPortControlRequest | 1.3.6.1.4.1.231.7.1.2.1.1.3.2.1 | shephysportcontrolrequesttype | read-write |
The port commands : changeAdminState: the AdminState of the current port shall be changed. changeAlarmSeverityProfile: the alarm severity profile of the port is changed. resetStatisticCounters: reset all statistic counters in if- and ifx-table for this port. changeUserLabel: change the value of the UserLabel for this port. changeOperStateTrapEnablePermission: change the permission to send operstate trap for this port. Notifications : shePhysPortControlResult at the command ending in case of long running command. |
shePhysPortControlStatus | 1.3.6.1.4.1.231.7.1.2.1.1.3.2.2 | shecontrolstatustype | read-only |
The status of a user command. |
shePhysPortControlIfIndex | 1.3.6.1.4.1.231.7.1.2.1.1.3.2.3 | interfaceindex | read-write |
The IfIndex of the port that shall be configured. |
shePhysPortControlAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.1.1.3.2.4 | shealarmsevprofileindex | read-write |
The new AlarmSeverityIndex of the alarm severity profile assigned to the port. |
shePhysPortControlAdminState | 1.3.6.1.4.1.231.7.1.2.1.1.3.2.5 | sheadminstatetype | read-write |
The desired AdminState of the port that shall be configured. |
shePhysPortControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.1.1.3.2.6 | unsigned32 | read-only |
The time stamp of the last command (end of command). |
shePhysPortControlTimer | 1.3.6.1.4.1.231.7.1.2.1.1.3.2.7 | unsigned32 | read-only |
The maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysRiResult . |
shePhysPortControlReqResult | 1.3.6.1.4.1.231.7.1.2.1.1.3.2.8 | shephysportcontrolrequestresulttype | read-only |
The result of the last user command. |
shePhysPortControlUserLabel | 1.3.6.1.4.1.231.7.1.2.1.1.3.2.9 | octet string | read-write |
Port specific ASCII identification. This string is only used by the ACI to identifying a physical UserPort. The data is stored in NE but has no further meaning for the NE himself. |
shePhysPortControlOperStateTrapEnable | 1.3.6.1.4.1.231.7.1.2.1.1.3.2.10 | shepermissiontype | read-write |
Enable/disable OperStateTrap's. Current status could be read from ifx-table. |
shePhysPortNEInfo | 1.3.6.1.4.1.231.7.1.2.1.1.3.3 | |||
shePhysPortAdslCount | 1.3.6.1.4.1.231.7.1.2.1.1.3.3.1 | unsigned32 | read-only |
This attribute returns the current number of available physical port's of type ADSL (ifType 94) of the NE. The attribute could be used by the management system for licensing. |
shePhysPortShdslCount | 1.3.6.1.4.1.231.7.1.2.1.1.3.3.2 | unsigned32 | read-only |
This attribute returns the current number of available physical port's of type SHDSL (ifType 96) of the NE. The attribute could be used by the management system for licensing. |
shePhysPortVdslCount | 1.3.6.1.4.1.231.7.1.2.1.1.3.3.3 | unsigned32 | read-only |
This attribute returns the current number of available physical port's of type VDSL (ifType 97) of the NE. The attribute could be used by the management system for licensing. |
shePhysPortAdsl2Count | 1.3.6.1.4.1.231.7.1.2.1.1.3.3.4 | unsigned32 | read-only |
This attribute returns the current number of available physical port's of type ADSL2 (ifType 230) of the NE. The attribute could be used by the management system for licensing. |
shePhysPortVoipCount | 1.3.6.1.4.1.231.7.1.2.1.1.3.3.5 | unsigned32 | read-only |
This attribute returns the current number of available physical port's of type VOIP (ifType 104) of the NE. The attribute could be used by the management system for licensing. |
shePhysPortIsdnCount | 1.3.6.1.4.1.231.7.1.2.1.1.3.3.6 | unsigned32 | read-only |
This attribute returns the current number of available physical port's of type ISDN (ifType 63) of the NE. The attribute could be used by the management system for licensing. |
shePhysRedundancyObjects | 1.3.6.1.4.1.231.7.1.2.1.1.4 | |||
shePhysBoardRedundancyControl | 1.3.6.1.4.1.231.7.1.2.1.1.4.1 | |||
shePhysBrdControlRequest | 1.3.6.1.4.1.231.7.1.2.1.1.4.1.1 | shephysbrdcontrolrequesttype | read-write |
The user commands for board redundancy and switch over. enableBoardRedundancy, disableBoardRedundancy: to enable/disable board redundancy. boardSwitchOver: applicable when board redundancy is enabled and the standby board is in the state ShePhysCardProtState = standby_protecting (There is no traffic interruption in case of swithover.) boardSwitchOverForced: applicable when board redundancy is enabled, ShePhysCardProtState = standby_protecting or standby_degraded. modifyRedundancyFeature: applicable only for CXU-board modifyRedundancyInterlinksFeature: applicable only for CXU-board |
shePhysBrdControlStatus | 1.3.6.1.4.1.231.7.1.2.1.1.4.1.2 | shecontrolstatustype | read-only |
The status of the control request. |
shePhysBrdControlReqResult | 1.3.6.1.4.1.231.7.1.2.1.1.4.1.3 | shephysbrdcontrolrequestresulttype | read-only |
The result of the last user command. |
shePhysBrdControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.1.1.4.1.4 | unsigned32 | read-only |
The time stamp of the last command (end of command). |
shePhysBrdControlTimer | 1.3.6.1.4.1.231.7.1.2.1.1.4.1.5 | unsigned32 | read-only |
The maximum wait time for the manager for a line redundancy user command. |
shePhysBrdControlEntPhysicalIndex | 1.3.6.1.4.1.231.7.1.2.1.1.4.1.6 | physicalindex | read-write |
The entPhysicalIndex of the card to be switched over or modified. |
shePhysBrdControlRedundancyFeature | 1.3.6.1.4.1.231.7.1.2.1.1.4.1.7 | shephysredundancyfeaturetype | read-write |
Only applicable for CXU-board. |
shePhysBrdControlRedundancyInterlink | 1.3.6.1.4.1.231.7.1.2.1.1.4.1.8 | shephysredundancyinterlinktype | read-write |
Configure a medium type for connecting interlink ports on board redundancy. |
shePhysRedundancyBase | 1.3.6.1.4.1.231.7.1.2.1.1.4.2 | |||
shePhysRedundancyFeature | 1.3.6.1.4.1.231.7.1.2.1.1.4.2.1 | shephysredundancyfeaturetype | read-only |
Configure special features they are importend for redundancy handling. |
shePhysRedundancyInterlink | 1.3.6.1.4.1.231.7.1.2.1.1.4.2.2 | shephysredundancyinterlinktype | read-only |
Configure a medium type for connecting interlink ports on board redundancy. |
shePhysicalNotifications | 1.3.6.1.4.1.231.7.1.2.1.1.5 | |||
shePhysRackEvents | 1.3.6.1.4.1.231.7.1.2.1.1.5.1 | |||
shePhysRackControlResult | 1.3.6.1.4.1.231.7.1.2.1.1.5.1.1 |
Notification of rack command ending and result. |
||
shePhysRackAlarms | 1.3.6.1.4.1.231.7.1.2.1.1.5.2 | |||
shePhysDCAlarm0 | 1.3.6.1.4.1.231.7.1.2.1.1.5.2.1 |
Break down of power supply fan group 0 . |
||
shePhysDCAlarm1 | 1.3.6.1.4.1.231.7.1.2.1.1.5.2.2 |
Break down of power supply fan group 1 . |
||
shePhysFanAlarm0 | 1.3.6.1.4.1.231.7.1.2.1.1.5.2.3 |
Depending on used shelftype the alarm stand for: M400, M600, M1200, MDUS: -> Alarm for Fan 0. G100 G200 G400, G600, M1100, G1100: -> Fan control defective. |
||
shePhysFanAlarm1 | 1.3.6.1.4.1.231.7.1.2.1.1.5.2.4 |
Depending on used shelftype the alarm stand for: M400, M600, M1200, MDUS: -> Alarm for Fan 1. G100 G200 G400, G600, M1100, G1100: -> Fan defective (Sum alarm). |
||
shePhysFanAlarm2 | 1.3.6.1.4.1.231.7.1.2.1.1.5.2.5 |
Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 2. G100 G200 G400, G600, M1100, G1100: -> Filter pad must be cleaned. MDUS: -> not used. |
||
shePhysFanAlarm3 | 1.3.6.1.4.1.231.7.1.2.1.1.5.2.6 |
Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 3. G100 G200 G400, G600, M1100, G1100, MDUS: -> not used |
||
shePhysFanAlarm4 | 1.3.6.1.4.1.231.7.1.2.1.1.5.2.7 |
Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 4 (if equiped). G100 G200 G400, G600, M1100, G1100, MDUS: -> not used |
||
shePhysFanAlarm5 | 1.3.6.1.4.1.231.7.1.2.1.1.5.2.8 |
Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 4 (if equiped). G100 G200 G400, G600, M1100, G1100, MDUS: -> not used |
||
shePhysShelfEvents | 1.3.6.1.4.1.231.7.1.2.1.1.5.3 | |||
shePhysShelfControlResult | 1.3.6.1.4.1.231.7.1.2.1.1.5.3.1 |
Notification of chassis command ending and result. |
||
shePhysShelfControlExternalAlarmsConfigurationChanged | 1.3.6.1.4.1.231.7.1.2.1.1.5.3.2 |
External alarm configuration changed. |
||
shePhysShelfControlRelativeHumidityAlarmThresholdChanged | 1.3.6.1.4.1.231.7.1.2.1.1.5.3.3 |
Alarm threshold configuration changed. |
||
shePhysShelfBatteryBackupModified | 1.3.6.1.4.1.231.7.1.2.1.1.5.3.4 |
Could only occur in shelf SHE hiX5622 R1.0 -> MDUS:E, if battery backupMode was modified. |
||
shePhysShelfControlExternalAlarmsOutputStatusChanged | 1.3.6.1.4.1.231.7.1.2.1.1.5.3.5 |
External alarm output status configuration changed. |
||
shePhysShelfAlarms | 1.3.6.1.4.1.231.7.1.2.1.1.5.4 | |||
shePhysShelfMupState1 | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.1 |
Break down of redundancy power supply 1 ( Power Supply or battery ). Note: This alarm will never occur in case of used shelftype G400R/G600:R:E with plugged PM_R module. |
||
shePhysShelfMupState2 | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.2 |
Break down of redundancy power supply 2 ( Power Supply or battery ). Note: This alarm will never occur in case of used shelftype G400R/G600:R:E with plugged PM_R module. |
||
shePhysShelfExternalAlarm01 | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.3 |
External Alarm 01. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): AC Failure -> Powering Alarm - Loss of external power. |
||
shePhysShelfExternalAlarm02 | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.4 |
External Alarm 2. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): DC Failure (internal fault) -> Equipment Alarm - A functional failure on an internal interface. |
||
shePhysShelfExternalAlarm03 | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.5 |
External Alarm 3. Default usage in hix5622 system R1.0 (shelftyp MDUS:E): Deep battery discharge -> Battery Low - battery is provisioned and present but voltage is too low. |
||
shePhysShelfExternalAlarm04 | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.6 |
External Alarm 4. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery missing -> Battery is provisioned but missing. |
||
shePhysShelfExternalAlarm05 | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.7 |
External Alarm 5. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery replace (end of life) -> Battery Failure - Battery is provisioned and present but cannot recharge. |
||
shePhysShelfExternalAlarm06 | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.8 |
External Alarm 6. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Door Contact -> Physical Intrusion alarm. |
||
shePhysShelfExternalAlarm07 | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.9 |
External Alarm 7. |
||
shePhysShelfExternalAlarm08 | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.10 |
External Alarm 8. |
||
shePhysShelfRelativeHumidityAlarm | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.11 |
The configured threshold for relative humidity was reached. |
||
shePhysShelfHeatExchangerIn | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.12 |
Break down of 1 or more fan of the heat exchanger inner circle. Note: This alarm could only occur in case of used shelftype G400R/G600:R:E with plugged PM_R module. |
||
shePhysShelfHeatExchangerOut | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.13 |
Break down of 1 or more fan of the heat exchanger outer circle. Note: This alarm could only occur in case of used shelftype G400R/G600:R:E with plugged PM_R module. |
||
shePhysShelfExtAlarmCollectorNotConnected | 1.3.6.1.4.1.231.7.1.2.1.1.5.4.14 |
External Alarm Collector is not connected. The detection of external Alarms is not possible. Only valid if powermodule PM:ONU:2G:E is used. |
||
shePhysCardEvents | 1.3.6.1.4.1.231.7.1.2.1.1.5.5 | |||
shePhysCardControlResult | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.1 |
Notification sent end of a long running card command. |
||
shePhysCardAdminStateChanged | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.2 |
The cards adminState changed. |
||
shePhysCardStateChanged | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.3 |
The cards operational/availabilty state changed. |
||
shePhysCardReset | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.4 |
Card is performing a reset. |
||
shePhysCardResetEnd | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.5 |
End of card reset. |
||
shePhysCardCreated | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.6 |
Card created. |
||
shePhysCardDeleted | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.7 |
Card deleted. |
||
shePhysCardDeletionStarted | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.8 |
The card deletion procedure in the NE was started. |
||
shePhysContainerCardTypeConverted | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.9 |
Card type converted. |
||
shePhysCardConvertionStarted | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.10 |
The card convertion procedure in the NE was started. |
||
shePhysCardPlugged | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.11 |
A card was plugged. This notification contains a list of two entPhysicalIndices. First is the entPhysicalIndex of the slot, were these module was plugged and the second, the entPhysicalIndex of the card itself. |
||
shePhysCardUnplugged | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.12 |
A card was unplugged. This notification contains a list of two entPhysicalIndices. First is the entPhysicalIndex of the slot, were these module was plugged before and the second, the entPhysicalIndex of the card itself. |
||
shePhysCardChangedTemperatureThreshold | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.13 |
The temperature threshold has been configured. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5. |
||
shePhysCardTemperatureWarningThresholdsChanged | 1.3.6.1.4.1.231.7.1.2.1.1.5.5.14 |
Configuration event. |
||
shePhysCardAlarms | 1.3.6.1.4.1.231.7.1.2.1.1.5.6 | |||
shePhysCardTypeMismatch | 1.3.6.1.4.1.231.7.1.2.1.1.5.6.1 |
Wrong card is plugged. |
||
shePhysCardFailure | 1.3.6.1.4.1.231.7.1.2.1.1.5.6.2 |
Card out of service. |
||
shePhysCardProblem | 1.3.6.1.4.1.231.7.1.2.1.1.5.6.3 |
Card partly out of service. |
||
shePhysCardNotInstalled | 1.3.6.1.4.1.231.7.1.2.1.1.5.6.4 |
Card not plugged. |
||
shePhysCardTemperaturePowerDown | 1.3.6.1.4.1.231.7.1.2.1.1.5.6.5 |
Temperature alarm. The IU has detect high temperature and start's first action to reduce power consumption. |
||
shePhysCardOverTemperatureReset | 1.3.6.1.4.1.231.7.1.2.1.1.5.6.6 |
CXU has forced IU-Card to reset because of over temperature. |
||
shePhysCardOverTemperatureThreshold | 1.3.6.1.4.1.231.7.1.2.1.1.5.6.7 |
Card temperature Threshold alarm. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5. |
||
shePhysCardTemperatureWarning | 1.3.6.1.4.1.231.7.1.2.1.1.5.6.8 |
Temperature warning alarm. The CXU has detected a higher temperature then the configured value. |
||
shePhysCardSWVersionProblem | 1.3.6.1.4.1.231.7.1.2.1.1.5.6.9 |
Card out of service due to wrong SW version. Please upgrade! |
||
shePhysPortEvents | 1.3.6.1.4.1.231.7.1.2.1.1.5.7 | |||
shePhysPortAdminStateChanged | 1.3.6.1.4.1.231.7.1.2.1.1.5.7.1 |
The ports adminState changed. Could be send as a collection trap. That means, this notification could contain more then one indexed ifAdminState. During system startup normaly a large number of notifications are needed. In such a case, it is possible to send only one notification per card which contain the ifAdminStates of all port's. |
||
shePhysPortOperStateChanged | 1.3.6.1.4.1.231.7.1.2.1.1.5.7.2 |
The ports operational state changed. Could be send as a collection trap. That means, this notification could contain more then one indexed ifOperState. During system startup normaly a large number of notifications are needed. In such a case, it is possible to send only one notification per card which contain the ifOperStates of all port's. |
||
shePhysPortControlResult | 1.3.6.1.4.1.231.7.1.2.1.1.5.7.3 |
Notification of port command ending and result. |
||
shePhysPortCreated | 1.3.6.1.4.1.231.7.1.2.1.1.5.7.4 |
Notification about port creation. Could be send as a collection trap. That means, this notification could contain more then one ifIndex. In case of a card creation sequence, normaly a large number of PortCreated-notifications are needed. In such a case, it is possible to send only one notification which contain the ifIndeces of all created port's for the entPhysicalIndex of this new card. |
||
shePhysPortDeleted | 1.3.6.1.4.1.231.7.1.2.1.1.5.7.5 |
Notification about the succesfull delete of a port. Could be send as a collection trap. That means, this notification could contain more then one ifIndex. In case of a card deletion sequence, normaly a large number of PortDeleted-notifications are needed. In such a case, it is possible to send only one notification which contain the ifIndeces of all deleted port's for the entPhysicalIndex of this card. |
||
shePhysPortAlarms | 1.3.6.1.4.1.231.7.1.2.1.1.5.8 | |||
shePhysPortOperStateDown | 1.3.6.1.4.1.231.7.1.2.1.1.5.8.1 |
This is a operstate-down alarm trap. This trap could not be send as collection trap (different from OperStateChanged - Event trap)!! This trap could be blocked by setting in alarmseverity-profile. |
||
shePhysRedundancyEvents | 1.3.6.1.4.1.231.7.1.2.1.1.5.9 | |||
shePhysBrdControlResult | 1.3.6.1.4.1.231.7.1.2.1.1.5.9.1 |
Notification of board redundancy command ending and result. |
||
shePhysRedundancyStateChanged | 1.3.6.1.4.1.231.7.1.2.1.1.5.9.2 |
Notification of change of redundancy ralated attributes of a card. |
||
shePhysRedundancyFeatureModified | 1.3.6.1.4.1.231.7.1.2.1.1.5.9.3 |
Modification response trap. |
||
shePhysRedundancyInterlinkModified | 1.3.6.1.4.1.231.7.1.2.1.1.5.9.4 |
The medium type for interlink has been changed. |
||
shePhysRedundancyAlarms | 1.3.6.1.4.1.231.7.1.2.1.1.5.10 | |||
shePhysRedundancyNoRedundancy | 1.3.6.1.4.1.231.7.1.2.1.1.5.10.1 |
Redundancy is not available for a card. |
||
shePhysRackObjects | 1.3.6.1.4.1.231.7.1.2.1.1.6 | |||
shePhysRackTable | 1.3.6.1.4.1.231.7.1.2.1.1.6.1 | no-access |
The shelf/chassis table. |
|
1.3.6.1.4.1.231.7.1.2.1.1.6.1.1 | no-access |
Entry of the rack table. The entries represent the SHE rack. |
||
shePhysRackAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.1.1.6.1.1.1 | shealarmsevprofileindex | read-only |
A pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1. |
shePhysRackControl | 1.3.6.1.4.1.231.7.1.2.1.1.6.2 | |||
shePhysRackControlRequest | 1.3.6.1.4.1.231.7.1.2.1.1.6.2.1 | shephyscontrolrequesttype | read-write |
The rack commands : changeAlarmSeverityProfile: the alarm severity profile of the rack is changed. Notifications : shePhysRackControlResult at the command ending in case of long running command. |
shePhysRackControlStatus | 1.3.6.1.4.1.231.7.1.2.1.1.6.2.2 | shecontrolstatustype | read-only |
The status of a user command. |
shePhysRackControlIndex | 1.3.6.1.4.1.231.7.1.2.1.1.6.2.3 | physicalindex | read-write |
The entPhysicalIndex of the rack. |
shePhysRackControlAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.1.1.6.2.4 | shealarmsevprofileindex | read-write |
The new AlarmSeverityIndex of the alarm severity profile assigned to the rack. |
shePhysRackControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.1.1.6.2.5 | unsigned32 | read-only |
The time stamp of the last command (end of command). |
shePhysRackControlTimer | 1.3.6.1.4.1.231.7.1.2.1.1.6.2.6 | unsigned32 | read-only |
The maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysResult . |
shePhysRackControlReqResult | 1.3.6.1.4.1.231.7.1.2.1.1.6.2.7 | shephyscontrolrequestresulttype | read-only |
The result of the last user command. |
shePhysShelfObjects | 1.3.6.1.4.1.231.7.1.2.1.1.7 | |||
shePhysShelfTable | 1.3.6.1.4.1.231.7.1.2.1.1.7.1 | no-access |
The shelf/chassis table. |
|
1.3.6.1.4.1.231.7.1.2.1.1.7.1.1 | no-access |
Entry of the chassis table. The entries represent the SHE shelf(s). |
||
shePhysShelfAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.1 | shealarmsevprofileindex | read-only |
A pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1. |
shePhysShelfTypeCode | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.2 | displaystring | read-only |
Contains the typecode for the possible used She-Shelf's. Depending on the detected shelftype-code the corresponding system version will be displayed. Systemversion -> Shelftypes SHE hiX5635 -> M1200:E, M1100:E, G1100:E, G1100:A, G1100:B:E SHE hiX5630 -> M600:E, G600:E, G600:R:E, M600:DF:E SHE hiX5625 -> M400:E, G400:E, G400:R:A, SHE hiX5622 R1.0 -> MDUS:E (obsolete because release was canceled) SHE hiX5608 -> 'empty' string because no shelf is used, single box system Shelftype's 2 generation - only new 2G powermodules could be used! (>= with R2.8 maintenance) SHE hiX5635 -> G1100:2G:E, M1100:2G:E SHE hiX5630 -> G600:2G:E, G600:R:2G:E, SHE hiX5625 -> G400:2G:E, G400:R:2G:E, SHE hiX5622 -> G200:2G:E, G200S:2G:E |
shePhysShelfExternalAlarmOutput01Status | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.3 | shephysshelfexternalalarmoutputstatustype | read-only |
Status of the external alarm output 01. |
shePhysShelfExternalAlarmOutput01Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.4 | octet string | read-only |
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
shePhysShelfExternalAlarmOutput02Status | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.5 | shephysshelfexternalalarmoutputstatustype | read-only |
Status of the external alarm output 02. |
shePhysShelfExternalAlarmOutput02Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.6 | octet string | read-only |
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
shePhysShelfExternalAlarmOutput03Status | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.7 | shephysshelfexternalalarmoutputstatustype | read-only |
Status of the external alarm output 03. |
shePhysShelfExternalAlarmOutput03Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.8 | octet string | read-only |
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
shePhysShelfExternalAlarm01Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.9 | shephysshelfexternalalarmleveltype | read-only |
Configured level for active alarm. |
shePhysShelfExternalAlarm01Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.10 | octet string | read-only |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hiX5622 R1.0 system (shelftyp MDUS:E): AC Failure -> Powering Alarm - Loss of external power Default usage in hiX5608 R1.0 system: Door Contact -> Physical Intrusion alarm. |
shePhysShelfExternalAlarm02Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.11 | shephysshelfexternalalarmleveltype | read-only |
Configured level for active alarm. |
shePhysShelfExternalAlarm02Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.12 | octet string | read-only |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): DC Failure (internal fault) -> Equipment Alarm - A functional failure on an internal interface. |
shePhysShelfExternalAlarm03Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.13 | shephysshelfexternalalarmleveltype | read-only |
Configured level for active alarm. |
shePhysShelfExternalAlarm03Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.14 | octet string | read-only |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Deep battery discharge -> Battery Low - battery is provisioned and present but voltage is too low. |
shePhysShelfExternalAlarm04Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.15 | shephysshelfexternalalarmleveltype | read-only |
Configured level for active alarm. |
shePhysShelfExternalAlarm04Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.16 | octet string | read-only |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery missing -> Battery is provisioned but missing. |
shePhysShelfExternalAlarm05Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.17 | shephysshelfexternalalarmleveltype | read-only |
Configured level for active alarm. |
shePhysShelfExternalAlarm05Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.18 | octet string | read-only |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery replace (end of life) -> Battery Failure - Battery is provisioned and present but cannot recharge. |
shePhysShelfExternalAlarm06Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.19 | shephysshelfexternalalarmleveltype | read-only |
Configured level for active alarm. |
shePhysShelfExternalAlarm06Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.20 | octet string | read-only |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Door Contact -> Physical Intrusion alarm. |
shePhysShelfExternalAlarm07Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.21 | shephysshelfexternalalarmleveltype | read-only |
Configured level for active alarm. |
shePhysShelfExternalAlarm07Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.22 | octet string | read-only |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
shePhysShelfExternalAlarm08Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.23 | shephysshelfexternalalarmleveltype | read-only |
Configured level for active alarm. |
shePhysShelfExternalAlarm08Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.24 | octet string | read-only |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
shePhysShelfRelativeHumidity | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.25 | unsigned32 | read-only |
Environmentale parameter for relative humidity in %. This parameter is only valid for shelftype G400R//G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. In all other cases the value 255 will report, that a valid measurement result is not available. |
shePhysShelfRelativeHumidityAlarmOn | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.26 | unsigned32 | read-only |
Environmentale parameter for relative humidity alarm threshold on. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. |
shePhysShelfRelativeHumidityAlarmOff | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.27 | unsigned32 | read-only |
Environmentale parameter for relative humidity alarm threshold off. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. |
shePhysShelfBatteryBackupOption | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.28 | truthvalue | read-only |
Indication wether the SHE supports battery backup. Only shelftype SHE hiX5622 R1.0 -> MDUS:E will support battery backup, otherwise false. |
shePhysShelfBatteryBackupMode | 1.3.6.1.4.1.231.7.1.2.1.1.7.1.1.29 | truthvalue | read-only |
Indication wether battery backup is provisioned. Only valid for shelftype SHE hiX5622 R1.0 -> MDUS:E. |
shePhysShelfControl | 1.3.6.1.4.1.231.7.1.2.1.1.7.2 | |||
shePhysShelfControlRequest | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.1 | shephyscontrolrequesttype | read-write |
The chassis commands : changeAlarmSeverityProfile: the alarm severity profile of the chassis is changed. changeShelfExternalAlarmSettings change level for active external alarms and set a descriptional name for usage Notifications : shePhysShelfControlExternalAlarmsConfigurationChanged shePhysShelfControlResult at the command ending in case of long running command. changeShelfRelativeHumidityAlarmThreshold change the alarm threshold configuration for environmental parameter relative humidity Notifications: shePhysShelfControlRelativeHumidityAlarmThresholdChanged hiX5622 R1.0 only: changeShelfBatteryBackupMode: shePhysShelfControlBatteryBackupMode Notifications: shePhysShelfBatteryBackupModified New with R2.8: changeShelfExternalAlarmOutputStatus change status external alarm outputs Notifications : shePhysShelfControlExternalAlarmsOutputStatusChanged |
shePhysShelfControlStatus | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.2 | shecontrolstatustype | read-only |
The status of a user command. |
shePhysShelfControlIndex | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.3 | physicalindex | read-write |
The entPhysicalIndex of the shelf. |
shePhysShelfControlTimeStamp | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.4 | unsigned32 | read-only |
The time stamp of the last command (end of command). |
shePhysShelfControlTimer | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.5 | unsigned32 | read-only |
The maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysRiResult . |
shePhysShelfControlReqResult | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.6 | shephyscontrolrequestresulttype | read-only |
The result of the last user command. |
shePhysShelfControlAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.7 | shealarmsevprofileindex | read-write |
The new AlarmSeverityIndex of the alarm severity profile assigned to the chassis. |
shePhysShelfControlExternalAlarmOutput01Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.8 | octet string | read-write |
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlExternalAlarmOutput02Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.9 | octet string | read-write |
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlExternalAlarmOutput03Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.10 | octet string | read-write |
Description for usage of this external alarm output. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlExternalAlarm01Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.11 | shephysshelfexternalalarmleveltype | read-write |
Configured level for active alarm. |
shePhysShelfControlExternalAlarm01Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.12 | octet string | read-write |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlExternalAlarm02Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.13 | shephysshelfexternalalarmleveltype | read-write |
Configured level for active alarm. |
shePhysShelfControlExternalAlarm02Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.14 | octet string | read-write |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlExternalAlarm03Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.15 | shephysshelfexternalalarmleveltype | read-write |
Configured level for active alarm. |
shePhysShelfControlExternalAlarm03Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.16 | octet string | read-write |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlExternalAlarm04Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.17 | shephysshelfexternalalarmleveltype | read-write |
Configured level for active alarm. |
shePhysShelfControlExternalAlarm04Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.18 | octet string | read-write |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlExternalAlarm05Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.19 | shephysshelfexternalalarmleveltype | read-write |
Configured level for active alarm. |
shePhysShelfControlExternalAlarm05Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.20 | octet string | read-write |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlExternalAlarm06Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.21 | shephysshelfexternalalarmleveltype | read-write |
Configured level for active alarm. |
shePhysShelfControlExternalAlarm06Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.22 | octet string | read-write |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlExternalAlarm07Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.23 | shephysshelfexternalalarmleveltype | read-write |
Configured level for active alarm. |
shePhysShelfControlExternalAlarm07Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.24 | octet string | read-write |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlExternalAlarm08Level | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.25 | shephysshelfexternalalarmleveltype | read-write |
Configured level for active alarm. |
shePhysShelfControlExternalAlarm08Usage | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.26 | octet string | read-write |
Description for usage of this external alarm. Only for managment interface and no special meaning for the NE. |
shePhysShelfControlRelativeHumidityAlarmOn | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.27 | unsigned32 | read-write |
Configure the environmentale parameter for relative humidity alarm threshold on. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. |
shePhysShelfControlRelativeHumidityAlarmOff | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.28 | unsigned32 | read-write |
Configure the environmentale parameter for relative humidity alarm threshold off. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. |
shePhysShelfControlBatteryBackupMode | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.29 | truthvalue | read-write |
Provisioning of battery backup. Only valid for shelftype SHE hiX5622 R1.0 -> MDUS:E. |
shePhysShelfControlExternalAlarmOutput01Status | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.30 | shephysshelfexternalalarmoutputstatustype | read-write |
Set the status of the external alarm output 01. |
shePhysShelfControlExternalAlarmOutput02Status | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.31 | shephysshelfexternalalarmoutputstatustype | read-write |
Set the status of the external alarm output 02. |
shePhysShelfControlExternalAlarmOutput03Status | 1.3.6.1.4.1.231.7.1.2.1.1.7.2.32 | shephysshelfexternalalarmoutputstatustype | read-write |
Set the status of the external alarm output 03. |
shePhysicalConformance | 1.3.6.1.4.1.231.7.1.2.1.1.100 | |||
shePhysicalGroups | 1.3.6.1.4.1.231.7.1.2.1.1.100.1 | |||
shePhysicalGroup | 1.3.6.1.4.1.231.7.1.2.1.1.100.1.1 |
Description. |
||
shePhysicalControlGroup | 1.3.6.1.4.1.231.7.1.2.1.1.100.1.2 |
Description. |
||
shePhysicalNotificationGroup | 1.3.6.1.4.1.231.7.1.2.1.1.100.1.3 |
This group supports notifications of significant conditions associated with physical objects. |
||
shePhysicalObsoleteGroup | 1.3.6.1.4.1.231.7.1.2.1.1.100.1.4 |
Description. |
||
shePhysicalObsoleteNotificationGroup | 1.3.6.1.4.1.231.7.1.2.1.1.100.1.5 |
Description. |
||
shePhysicalCompliances | 1.3.6.1.4.1.231.7.1.2.1.1.100.2 | |||
shePhysicalMibCompliance | 1.3.6.1.4.1.231.7.1.2.1.1.100.2.1 |
The compliance statement for SNMP entities which manage physical interfaces in SHE. |