Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
|
|||
Object Name | OID | Type | Access | Info |
sheEthernetMib | 1.3.6.1.4.1.231.7.1.2.1.5 |
This MIB contains all ethernet specific configurations and informations. Some statistic counters from the Etherlike MIB are included. |
||
sheEthernet | 1.3.6.1.4.1.231.7.1.2.1.5.1 | |||
sheEthernetPortTable | 1.3.6.1.4.1.231.7.1.2.1.5.1.1 | no-access |
The ethernet port table. |
|
1.3.6.1.4.1.231.7.1.2.1.5.1.1.1 | no-access |
Each entry represents a physical ethernet interface. Index by ifIndex. |
||
sheEthernetPortType | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.2 | sheethernetporttype | read-only |
This value must always be configured. SheEthernetPortType 0 - unknown 1 - electrical 2 - optical Select the type of used interface. |
sheEthernetPortTransmissionRate | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.3 | integer32 | read-only |
The speed of port. Unit is Mbit/s. A modification is only useful for electrical-interfaces. Optical-interfaces will always support 1000 MBIT/s. |
sheEthernetPortDuplexMode | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.4 | sheethernetduplextype | read-only |
The duplex status of port. The SHE will support always full duplex. SheEthernetDuplexType 1 - full 2 - half 3 - notAvailable |
sheEthernetPortFlowControl | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.5 | sheethernetflowcontroltype | read-only |
The flow-control mode of port. SheEthernetFlowControlType 0 - notAvailable 1 - disabled 2 - enabledBoth 4 - enabledSymetrical 8 - enabledAsymetrical The Symetrical types are only useful for electrical GE. |
sheEthernetPortNegotiationMode | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.6 | sheethernetnegotiationmodetype | read-only |
The Auto Negotiation mode of port. Default is auto. Speed will not be part of the autonegotiation. In case of Rate = 1000 and PortType = electrical, the negotiation mode is always auto (default). SheEthernetNegotiationType 1 - auto 2 - force 3 - notAvailable |
sheEthernetPortSfpTranseiver | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.7 | sheethernettranseivertype | read-only |
Code for electrical or optical compatibility. If 0 (unknown) maybe no SFP module is plugged and the following table values are not valid. For she only optical sfp-modules are allowed. SheEthernetTranseiverType 0 - unknown 1 - electrical (1000-T) 2 - electricalCoaxial(1000-CX) 3 - opticalLongHaul(1000-LX) 4 - opticalShortHaul(1000-SX) |
sheEthernetPortSfpVendorName | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.8 | octet string | read-only |
Sfp transeiver vendor name (ASCII). 16 Byte. |
sheEthernetPortSfpVendorPartNumber | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.9 | octet string | read-only |
Part number provided by SFP transeiver vendor (ASCII). 16 Byte. |
sheEthernetPortSfpVendorRevision | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.10 | octet string | read-only |
Revision level for part number provided by vendor (ASCII). 4 Byte. |
sheEthernetPortSfpVendorSerialNumber | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.11 | octet string | read-only |
Serial number provided by vendor (ASCII). 16 Byte. |
sheEthernetPortSfpDateCode | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.12 | octet string | read-only |
Vendor's manufacturing date code (ASCII). 2 Byte low order digit's for year (00=2000) 2 Byte digits of month's (01=Jan ... 12=Dec) 2 Byte day of month's (01..31) 2 Byte vendor specific lot-code, may be blank |
sheEthernetPortPhysicalRemoteChassis | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.13 | octet string | read-only |
Only used for Link Discovery. Set by operator. No further meaning for the NE. IP Address of the remote NE. |
sheEthernetPortPhysicalRemoteSlot | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.14 | integer32 | read-only |
Only used for Link Discovery. Set by operator. No further meaning for the NE. |
sheEthernetPortPhysicalRemotePort | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.15 | integer32 | read-only |
Only used for Link Discovery. Set by operator. No further meaning for the NE. |
sheEthernetPortPhysicalLinkDiscoveryMode | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.16 | shelinkdiscoverymodetype | read-only |
Only used for Link Discovery. Set by operator. No further meaning for the NE. Automatic mode is not supported by release 1.0. |
sheEthernetPortAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.17 | integer32 | read-only |
Used alarm severity for this portentry. |
sheEthernetPortStandbyLaserOff | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.18 | sheenabletype | read-only |
0 disable 1 enable |
sheEthernetPortSwitchoverOnLinkDown | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.19 | truthvalue | read-only |
A given port's link status is monitored. When link down for the port is detected, switchover from an active board to a standby board is performed. |
sheEthernetPortSfpDiagnosticValid | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.20 | truthvalue | read-only |
If set, the following corresponding status parameters are valid. |
sheEthernetPortSfpTemperature | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.21 | integer | read-only |
Internally measured transceiver temperature. Represented as a 16 bit signed twos complement value in increments of 1/256 degrees Celsius, yielding a total range of -128C to +128C. Temperature accuracy is vendor specific but must be better than +/-3 degrees Celsius over specified operating temperature and voltage.The temperature in degrees Celsius is given by the signed twos complement value with LSB equal to 1/256 C. Coding examples: DECIMAL HIGH BYTE LOW BYTE +127.996 7F FF +1.000 01 00 +0.004 00 01 -0.004 FF FF -1.000 FF 00 -127.996 80 01 -128.000 80 00 Only valid if sheEthernetPortSfpDiagnosticValid entry is true. |
sheEthernetPortSfpSupplyVoltage | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.22 | unsigned32 | read-only |
Internally measured transceiver supply voltage. Represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 .. 65535) with LSB equal to 100 uVolt, yielding a total range of 0 to +6.55 Volts. Practical considerations to be defined by transceiver manufacturer will tend to limit the actual bounds of the supply voltage measurement. Accuracy is vendor specific but must be better than +/-3% of the manufacturer's nominal value over specified operating temperature and voltage. Note that in some transceivers, transmitter supply voltage and receiver supply voltage are isolated. In that case, only one supply is monitored. Only valid if sheEthernetPortSfpDiagnosticValid entry is true. |
sheEthernetPortSfpLaserBiasCurrent | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.23 | unsigned32 | read-only |
Measured TX bias current in uA. Represented as a 16 bit unsigned integer with the current defined as the full 16 bit value (0 .. 65535) with LSB equal to 2 uA, yielding a total range of 0 to 131 mA. Accuracy is vendor specific but must be better than +/-10% of the manufacturer's nominal value over specified operating temperature and voltage. Only valid if sheEthernetPortSfpDiagnosticValid entry is true. |
sheEthernetPortSfpTxPower | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.24 | unsigned32 | read-only |
Measured TX output power. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 .. 65535) with LSB equal to 0.1 uW, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm). Data is assumed to be based on measurement of laser monitor photodiode current. It is factory calibrated to absolute units using the most representative fiber output type. Accuracy is vendor specific but must be better than +/-3dB over specified temperature and voltage. Data is not valid when the transmitter is disabled. Only valid if sheEthernetPortSfpDiagnosticValid entry is true. |
sheEthernetPortSfpRxPower | 1.3.6.1.4.1.231.7.1.2.1.5.1.1.1.25 | unsigned32 | read-only |
Measured RX received optical power. Represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 .. 65535) with LSB equal to 0.1 uW, yielding a total range of 0 to 6.5535 mW (~ -40 to +8.2 dBm). Absolute accuracy is dependent upon the exact optical wavelength. For the vendor specified wavelength, accuracy shall be better than +/-3dB over specified temperature and voltage. This accuracy shall be maintained for input power levels up to the lesser of maximum transmitted or maximum received optical power per the appropriate standard. It shall be maintained down to the minimum transmitted power minus cable plant loss (insertion loss or passive loss) per the appropriate standard. Absolute accuracy beyond this minimum required received input optical power range is vendor specific. Only valid if sheEthernetPortSfpDiagnosticValid entry is true. |
sheEthernetPortControl | 1.3.6.1.4.1.231.7.1.2.1.5.1.3 | |||
sheEthernetPortControlRequest | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.1 | sheethernetcontrolrequesttype | read-write |
setEthernetPortConfiguration: sheEthernetPortControlIndex sheEthernetPortControlType sheEthernetPortControlRate sheEthernetPortControlDuplexMode sheEthernetPortControlFlowControl sheEthernetPortControlNegotiationMode clearEthernetDot3StatsCounters: sheEthernetPortControlIndex setEthernetPortLinkDiscoveryValues: sheEthernetPortControlIndex sheEthernetPortControlPhysicalRemoteChassis sheEthernetPortControlPhysicalRemoteSlot sheEthernetPortControlPhysicalRemotePort sheEthernetPortControlPhysicalLinkDiscoveryMode setEthernetPortStandbyLaserOff: sheEthernetPortControlIndex sheEthernetPortControlStandbyLaserOff setEthernetPortSwitchoverOnLinkDown: sheEthernetPortControlIndex sheEthernetPortControlSwitchoverOnLinkDown setEthernetPortAlarmSeverityIndex: sheEthernetPortControlIndex sheEthernetPortControlAlarmSeverityIndex |
sheEthernetPortControlIndex | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.2 | integer32 | read-write |
The index if the interface to be configured. |
sheEthernetPortControlStatus | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.3 | shecontrolstatustype | read-only |
Status of the user command |
sheEthernetPortControlTimer | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.4 | gauge32 | read-only |
The maximum wait time for the manager for a long running user command. |
sheEthernetPortControlTimestamp | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.5 | unsigned32 | read-only |
Time stamp attribute set at the end of a command. |
sheEthernetPortControlReqResult | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.6 | sheethernetcontrolrequestresulttype | read-only |
The result of the last user command. |
sheEthernetPortControlType | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.7 | sheethernetporttype | read-write |
Select the type of used interface. SheEthernetPortType 1 - electrical 2 - optical |
sheEthernetPortControlRate | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.8 | integer32 | read-write |
Used Datarate. This configuration is only useful for electrical-interfaces. Optical-interfaces will always support 1000 MBIT/s. |
sheEthernetPortControlDuplexMode | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.9 | sheethernetduplextype | read-write |
Used DuplexMode. |
sheEthernetPortControlFlowControl | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.10 | sheethernetflowcontroltype | read-write |
Used FlowControl-value. |
sheEthernetPortControlNegotiationMode | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.11 | sheethernetnegotiationmodetype | read-write |
Used Negotiation mode. |
sheEthernetPortControlPhysicalRemoteChassis | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.12 | octet string | read-write |
Set RemoteCassis-Information. |
sheEthernetPortControlPhysicalRemoteSlot | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.13 | integer32 | read-write |
Set RemoteSlot-Information. |
sheEthernetPortControlPhysicalRemotePort | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.14 | integer32 | read-write |
Set RemotePort-Information. |
sheEthernetPortControlPhysicalLinkDiscoveryMode | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.15 | shelinkdiscoverymodetype | read-write |
Set mode of Remote-Information retrieval. |
sheEthernetPortControlAlarmSeverityIndex | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.16 | integer32 | read-write |
Set alarm severity for this portentry. |
sheEthernetPortControlStandbyLaserOff | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.17 | sheenabletype | read-write |
. |
sheEthernetPortControlSwitchoverOnLinkDown | 1.3.6.1.4.1.231.7.1.2.1.5.1.3.18 | truthvalue | read-write |
A given port's link status is monitored. When link down for the port is detected, switchover from an active board to a standby board is performed. |
sheDot3StatsTable | 1.3.6.1.4.1.231.7.1.2.1.5.1.4 | no-access |
From the Etherlike-Mib. |
|
1.3.6.1.4.1.231.7.1.2.1.5.1.4.1 | no-access |
One entry per physical ethernet interface. Index is ifIndex. |
||
sheDot3StatsAlignmentErrors | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.2 | counter32 | read-only |
A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the alignmentError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. |
sheDot3StatsFCSErrors | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.3 | counter32 | read-only |
A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the frameCheckError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. |
sheDot3StatsSingleCollisionFrames | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.4 | counter32 | read-only |
A count of successfully transmitted frames on a particular interface for which transmission is inhibited by exactly one collision. A frame that is counted by an instance of this object is also counted by the corresponding instance of either the ifOutUcastPkts, ifOutMulticastPkts, or ifOutBroadcastPkts, and is not counted by the corresponding instance of the dot3StatsMultipleCollisionFrames object. |
sheDot3StatsMultipleCollisionFrames | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.5 | counter32 | read-only |
A count of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision. A frame that is counted by an instance of this object is also counted by the corresponding instance of either the ifOutUcastPkts, ifOutMulticastPkts, or ifOutBroadcastPkts, and is not counted by the corresponding instance of the dot3StatsSingleCollisionFrames object. |
sheDot3StatsSQETestErrors | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.6 | counter32 | read-only |
A count of times that the SQE TEST ERROR message is generated by the PLS sublayer for a particular interface. The SQE TEST ERROR message is defined in section 7.2.2.2.4 of ANSI/IEEE 802.3-1985 and its generation is described in section 7.2.4.6 of the same document. |
sheDot3StatsDeferredTransmissions | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.7 | counter32 | read-only |
A count of frames for which the first transmission attempt on a particular interface is delayed because the medium is busy. The count represented by an instance of this object does not include frames involved in collisions. |
sheDot3StatsLateCollisions | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.8 | counter32 | read-only |
The number of times that a collision is detected on a particular interface later than 512 bit-times into the transmission of a packet. Five hundred and twelve bit-times corresponds to 51.2 microseconds on a 10 Mbit/s system. A (late) collision included in a count represented by an instance of this object is also considered as a (generic) collision for purposes of other collision-related statistics. |
sheDot3StatsExcessiveCollisions | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.9 | counter32 | read-only |
A count of frames for which transmission on a particular interface fails due to excessive collisions. |
sheDot3StatsInternalMacTransmitErrors | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.10 | counter32 | read-only |
A count of frames for which transmission on a particular interface fails due to an internal MAC sublayer transmit error. A frame is only counted by an instance of this object if it is not counted by the corresponding instance of either the dot3StatsLateCollisions object, the dot3StatsExcessiveCollisions object, or the dot3StatsCarrierSenseErrors object. The precise meaning of the count represented by an instance of this object is implementation- specific. In particular, an instance of this object may represent a count of transmission errors on a particular interface that are not otherwise counted. |
sheDot3StatsCarrierSenseErrors | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.11 | counter32 | read-only |
The number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame on a particular interface. The count represented by an instance of this object is incremented at most once per transmission attempt, even if the carrier sense condition fluctuates during a transmission attempt. |
sheDot3StatsFrameTooLongs | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.12 | counter32 | read-only |
A count of frames received on a particular interface that exceed the maximum permitted frame size. The count represented by an instance of this object is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC. |
sheDot3StatsInternalMacReceiveErrors | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.13 | counter32 | read-only |
A count of frames for which reception on a particular interface fails due to an internal MAC sublayer receive error. A frame is only counted by an instance of this object if it is not counted by the corresponding instance of either the dot3StatsFrameTooLongs object, the dot3StatsAlignmentErrors object, or the dot3StatsFCSErrors object. The precise meaning of the count represented by an instance of this object is implementation- specific. In particular, an instance of this object may represent a count of receive errors on a particular interface that are not otherwise counted. |
sheDot3StatsSymbolErrors | 1.3.6.1.4.1.231.7.1.2.1.5.1.4.1.14 | counter32 | read-only |
Symbol error. |
sheEthernetNotifications | 1.3.6.1.4.1.231.7.1.2.1.5.1.5 | |||
sheEthernetPortConfigurationChanged | 1.3.6.1.4.1.231.7.1.2.1.5.1.5.1 |
Port configuration notification. |
||
sheEthernetPortSfpDataChanged | 1.3.6.1.4.1.231.7.1.2.1.5.1.5.2 |
Port data change notification. |
||
sheEthernetDot3StatsCountersCleared | 1.3.6.1.4.1.231.7.1.2.1.5.1.5.3 |
Command execution notification. |
||
sheEthernetPortLinkDiscoveryValuesChanged | 1.3.6.1.4.1.231.7.1.2.1.5.1.5.4 |
Port configuration notification. |
||
sheEthernetPortStandbyLaserOffChanged | 1.3.6.1.4.1.231.7.1.2.1.5.1.5.6 |
Port configuration notification. |
||
sheEthernetPortSwitchoverOnLinkDownChanged | 1.3.6.1.4.1.231.7.1.2.1.5.1.5.7 |
sheEthernetPortControlSwitchoverOnLinkDown has been changed. |
||
sheEthernetConformance | 1.3.6.1.4.1.231.7.1.2.1.5.1.100 | |||
sheEthernetCompliances | 1.3.6.1.4.1.231.7.1.2.1.5.1.100.1 | |||
sheEthernetCompliance | 1.3.6.1.4.1.231.7.1.2.1.5.1.100.1.1 |
Description. |
||
sheEthernetGroups | 1.3.6.1.4.1.231.7.1.2.1.5.1.100.2 | |||
sheEthernetPortGroup | 1.3.6.1.4.1.231.7.1.2.1.5.1.100.2.1 |
Description. |
||
sheEthernetControlGroup | 1.3.6.1.4.1.231.7.1.2.1.5.1.100.2.2 |
Description. |
||
sheEthernetStatsGroup | 1.3.6.1.4.1.231.7.1.2.1.5.1.100.2.3 |
Description. |
||
sheEthernetNotificationGroup | 1.3.6.1.4.1.231.7.1.2.1.5.1.100.2.4 |
Description. |