Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 sni 1.3.6.1.4.1.231
         sniProductMibs 1.3.6.1.4.1.231.2
             sniExtensions 1.3.6.1.4.1.231.2.10
                   sniServerMgmt 1.3.6.1.4.1.231.2.10.2
                       sniInventory 1.3.6.1.4.1.231.2.10.2.1
                       sniCommon 1.3.6.1.4.1.231.2.10.2.2
                           sniBios 1.3.6.1.4.1.231.2.10.2.2.1
                           sniEisa 1.3.6.1.4.1.231.2.10.2.2.2
                           sniHd 1.3.6.1.4.1.231.2.10.2.2.3
                           sniBus 1.3.6.1.4.1.231.2.10.2.2.4
                           sniServerControl 1.3.6.1.4.1.231.2.10.2.2.5
                       sniPcSpecific 1.3.6.1.4.1.231.2.10.2.3
                       sniScb 1.3.6.1.4.1.231.2.10.2.4
                       sniOsSpecific 1.3.6.1.4.1.231.2.10.2.5
                           sniNetware 1.3.6.1.4.1.231.2.10.2.5.1
                           sniWinNt 1.3.6.1.4.1.231.2.10.2.5.2
                           sniOs2 1.3.6.1.4.1.231.2.10.2.5.3
                           sniUnix 1.3.6.1.4.1.231.2.10.2.5.4
                       sniOemComponents 1.3.6.1.4.1.231.2.10.2.6
                           sniOemDpt 1.3.6.1.4.1.231.2.10.2.6.1
                           sniOemMylex 1.3.6.1.4.1.231.2.10.2.6.2
                               sniMlxDiskArray 1.3.6.1.4.1.231.2.10.2.6.2.1
                       sniSecurity 1.3.6.1.4.1.231.2.10.2.7
                           sniSmSecurity 1.3.6.1.4.1.231.2.10.2.7.1
                       sniServerView 1.3.6.1.4.1.231.2.10.2.8
                       sieStatusAgent 1.3.6.1.4.1.231.2.10.2.11
                             sieStAgentInfo 1.3.6.1.4.1.231.2.10.2.11.1
                                 sieStAgentId 1.3.6.1.4.1.231.2.10.2.11.1.1 displaystring read-only
Agent identification string
                                 sieStAgentCompany 1.3.6.1.4.1.231.2.10.2.11.1.2 displaystring read-only
Agent company name
                                 sieStAgentVersionString 1.3.6.1.4.1.231.2.10.2.11.1.3 displaystring read-only
Agent version string . (i.e. 1.05)
                                 sieStAgentBuild 1.3.6.1.4.1.231.2.10.2.11.1.4 displaystring read-only
Build time and date of agent program implementation
                             sieStSystemStatus 1.3.6.1.4.1.231.2.10.2.11.2
                                 sieStSystemStatusValue 1.3.6.1.4.1.231.2.10.2.11.2.1 integer read-only
Overall status of this system: ok(1): all subsystems and components working properly, no failure degraded(2): redundant components failed or signal a warning error(3): severe problem, system may no longer work properly failed(4): this value is obsolete - will no longer appear unknown(5): none of the subsystems had a valid status (e.g. during initialization) Enumeration: 'failed': 4, 'degraded': 2, 'ok': 1, 'unknown': 5, 'error': 3.
                                 sieStSystemLastErrorMessage 1.3.6.1.4.1.231.2.10.2.11.2.2 displaystring read-only
Error message text of the component that has failed last. Empty string, if no error has happened since reboot. This object is not supported by all components and can therefore be empty although an error happened.
                                 sieStSubsystemList 1.3.6.1.4.1.231.2.10.2.11.2.3 displaystring read-only
List if subsystems included in this system, separated by blank spaces. E.g. 'Environment PowerSupply MassStorage'
                                 sieStSystemIdentify 1.3.6.1.4.1.231.2.10.2.11.2.4 integer read-write
Sets the signal IDENTIFY for the system: off(1): clear the identify signal / signal is off on(2): set the IDENTIFY signal not-available(3): identify signal ist not available (this value cannot be set) blinking(4): IDENTIFY LED blinking, used for different purposes Setting IDENTIFY by the ServerView application normally sets a LED to have the possibility to identify a system selected by ServerView. Enumeration: 'not-available': 3, 'on': 2, 'off': 1, 'blinking': 4.
                             sieStSubsystemStatus 1.3.6.1.4.1.231.2.10.2.11.3
                                 sieStSubsystemTable 1.3.6.1.4.1.231.2.10.2.11.3.1 no-access
Table containing the monitored subsystems
                                     sieStSubsystems 1.3.6.1.4.1.231.2.10.2.11.3.1.1 no-access
                                         sieStSubsystemNumber 1.3.6.1.4.1.231.2.10.2.11.3.1.1.1 integer read-only
Subsystem number (index, 1..n)
                                         sieStSubsystemName 1.3.6.1.4.1.231.2.10.2.11.3.1.1.2 displaystring read-only
Subsystem name. This name identifies the subsystem and will never be changed if once defined. This name is a string like 'Environment', 'PowerSupply', 'MassStorage' etc.
                                         sieStSubsystemStatusValue 1.3.6.1.4.1.231.2.10.2.11.3.1.1.3 integer read-only
Subsystem status value: ok(1): all components in this subsystem working properly degraded(2): redundant components failed or signal a warning error(3): severe problem, system may no longer work properly failed(4): this value is obsolete - will no longer appear unknown(5): none of the components had a valid status (initialization, no components) Enumeration: 'failed': 4, 'degraded': 2, 'ok': 1, 'unknown': 5, 'error': 3.
                                         sieStSubsystemLastErrorMessage 1.3.6.1.4.1.231.2.10.2.11.3.1.1.4 displaystring read-only
Error message text of the component that has failed last. Empty string, if no error has happened since reboot. This object is not supported by all components and can therefore be empty although an error happened.
                                         sieStSubsystemComponents 1.3.6.1.4.1.231.2.10.2.11.3.1.1.5 displaystring read-only
List if components (short names) included in this subsystem, separated by blank spaces; e.g. 'SvPowerSupply OemUpsAPC'
                                         sieStSubsystemDisplayName 1.3.6.1.4.1.231.2.10.2.11.3.1.1.6 displaystring read-only
Subsystem display name string.
                                 sieStNumberSubsystems 1.3.6.1.4.1.231.2.10.2.11.3.2 integer read-only
Number of available subsystems; this is the number of entries in the subsystem table
                             sieStComponentStatus 1.3.6.1.4.1.231.2.10.2.11.4
                                 sieStComponentTable 1.3.6.1.4.1.231.2.10.2.11.4.1 no-access
Table containing the monitored components
                                     sieStComponents 1.3.6.1.4.1.231.2.10.2.11.4.1.1 no-access
                                         sieStComponentNumber 1.3.6.1.4.1.231.2.10.2.11.4.1.1.1 integer read-only
Component number (index, 1..n)
                                         sieStComponentName 1.3.6.1.4.1.231.2.10.2.11.4.1.1.2 displaystring read-only
Component name/tag. This name identifies the component and will never be changed if once defined. This name is a string like 'SvEnvironment', 'SvVoltages', 'OemUpsAPC' etc.
                                         sieStComponentStatusValue 1.3.6.1.4.1.231.2.10.2.11.4.1.1.3 integer read-only
Component status value: ok(1): component is working properly degraded(2): redundant component has failed or signals a warning error(3): severe problem, system may no longer work properly failed(4): this value is obsolete - will no longer appear unknown(5): component had no valid status (initialization, no instances) notPresent(6): component is not present (e.g. empty socket) notManageable(7): component is not manageable Enumeration: 'ok': 1, 'unknown': 5, 'notManageable': 7, 'failed': 4, 'error': 3, 'notPresent': 6, 'degraded': 2.
                                         sieStComponentLastErrorMessage 1.3.6.1.4.1.231.2.10.2.11.4.1.1.4 displaystring read-only
Error message text of the current component. Empty string, if no error has happened since reboot. This object is not supported by all components and can therefore be empty although an error happened.
                                         sieStComponentDisplayName 1.3.6.1.4.1.231.2.10.2.11.4.1.1.5 displaystring read-only
Component display name string.
                                         sieStComponentConfirmFailure 1.3.6.1.4.1.231.2.10.2.11.4.1.1.6 integer read-write
Confirm a failure status of a component that does not automatically reset its status (e.g. BIOS selftest error). The error condition is removed after the failure has been confirmed. GET values: 0 - no failure to confirm; SET not possible >0 - component failure; SET a zero value to confirm SET values: 0 - confirm failure and remove error condition (setting other values than 0 is not possible)
                                 sieStNumberComponents 1.3.6.1.4.1.231.2.10.2.11.4.2 integer read-only
Number of available components; this is the number of entries in the component table
                             sieStAgentParameters 1.3.6.1.4.1.231.2.10.2.11.5
                                 sieStAgentType 1.3.6.1.4.1.231.2.10.2.11.5.1 displaystring read-only
Type of agent (i.e. 'Desktop' or 'Server'). This field can be used to launch the correct management front end application (DeskView or ServerView) in enterprise management systems.
                             sieStTrapParameters 1.3.6.1.4.1.231.2.10.2.11.10
                                   sieStTrapParamServerName 1.3.6.1.4.1.231.2.10.2.11.10.1 displaystring no-access
Name of server the trap occured at
                                   sieStTrapParamTimestamp 1.3.6.1.4.1.231.2.10.2.11.10.2 integer no-access
Time the trap occured (in seconds since 01/01/1970 00:00h)
                   sniTrapMib 1.3.6.1.4.1.231.2.10.5
                         sieStTrapStatusChanged 1.3.6.1.4.1.231.2.10.20.1100
System status has changed.