SENSATRONICS-EM1: View SNMP OID List / Download MIB

VENDOR: SENSATRONICS LLC


 Home MIB: SENSATRONICS-EM1
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 productEM1 1.3.6.1.4.1.16174.1.1.3
Description of EM1 code.
     unitInfo 1.3.6.1.4.1.16174.1.1.3.1
         unitName 1.3.6.1.4.1.16174.1.1.3.1.1 displaystring read-write
A user-definable unit name for the module being managed.
         unitModel 1.3.6.1.4.1.16174.1.1.3.1.2 displaystring read-only
The model number of the module being managed.
         unitManufacturer 1.3.6.1.4.1.16174.1.1.3.1.3 displaystring read-only
Company name of unit producer.
         unitWeb 1.3.6.1.4.1.16174.1.1.3.1.4 displaystring read-only
Website of manufacturer
         unitFirmware 1.3.6.1.4.1.16174.1.1.3.1.5 displaystring read-only
Firmware revision of unit.
         unitFWReleaseDate 1.3.6.1.4.1.16174.1.1.3.1.6 displaystring read-only
Release date of unit firmware.
         unitSerial 1.3.6.1.4.1.16174.1.1.3.1.7 displaystring read-only
Serial number of unit being managed.
         unitConfig 1.3.6.1.4.1.16174.1.1.3.1.8 integer read-only
In-house configuration MIB - do not use.
     configData 1.3.6.1.4.1.16174.1.1.3.2
         netInfo 1.3.6.1.4.1.16174.1.1.3.2.1
             netMode 1.3.6.1.4.1.16174.1.1.3.2.1.1 integer read-only
1 if the unit is self-configuring via DHCP, 0 if static IP assigned.
             netIP 1.3.6.1.4.1.16174.1.1.3.2.1.2 displaystring read-only
IP address of unit being managed.
             netNM 1.3.6.1.4.1.16174.1.1.3.2.1.3 displaystring read-only
Netmask of unit being managed.
             netGW 1.3.6.1.4.1.16174.1.1.3.2.1.4 displaystring read-only
Gateway of unit being managed.
             netHTTPPort 1.3.6.1.4.1.16174.1.1.3.2.1.5 integer read-write
Port the unit webserver listens on
         trapConfig 1.3.6.1.4.1.16174.1.1.3.2.2
             managerConfig 1.3.6.1.4.1.16174.1.1.3.2.2.1
                 managerIP 1.3.6.1.4.1.16174.1.1.3.2.2.1.1 displaystring read-write
IP of trap manager.
         measurementSystem 1.3.6.1.4.1.16174.1.1.3.2.3
             unitMode 1.3.6.1.4.1.16174.1.1.3.2.3.1 displaystring read-write
Set to C for Celsius units in probe data, F for Fahrenheit, K for Kelvin, R for Rankine, other values disallowed.
     sensorInfo 1.3.6.1.4.1.16174.1.1.3.3
         group1 1.3.6.1.4.1.16174.1.1.3.3.1
             group1Name 1.3.6.1.4.1.16174.1.1.3.3.1.1 displaystring read-write
Name of group 1 - User configurable, 16 characters
             group1TempName 1.3.6.1.4.1.16174.1.1.3.3.1.2 displaystring read-write
Name of Temperature probe in group 1 - User configurable, 16 characters
             group1TempDataStr 1.3.6.1.4.1.16174.1.1.3.3.1.3 displaystring read-write
Data from Temperature probe in group 1, string format, to 1 decimal place
             group1TempDataInt 1.3.6.1.4.1.16174.1.1.3.3.1.4 integer read-write
Data from Temperature probe in group 1, integer format, no decimal places
             group1HumidName 1.3.6.1.4.1.16174.1.1.3.3.1.5 displaystring read-write
Name of Humidity probe in group 1 - User configurable, 16 characters
             group1HumidDataStr 1.3.6.1.4.1.16174.1.1.3.3.1.6 displaystring read-write
Data from Humidity probe in group 1, string format, to 1 decimal place
             group1HumidDataInt 1.3.6.1.4.1.16174.1.1.3.3.1.7 integer read-write
Data from Humidity probe in group 1, integer format, no decimal places
             group1WetName 1.3.6.1.4.1.16174.1.1.3.3.1.8 displaystring read-write
Name of Wetness probe in group 1 - User configurable, 16 characters
             group1WetDataStr 1.3.6.1.4.1.16174.1.1.3.3.1.9 displaystring read-write
Data from Wetness probe in group 1, string format, to 1 decimal place
             group1WetDataInt 1.3.6.1.4.1.16174.1.1.3.3.1.10 integer read-write
Data from Wetness probe in group 1, integer format, no decimal places
         group2 1.3.6.1.4.1.16174.1.1.3.3.2
             group2Name 1.3.6.1.4.1.16174.1.1.3.3.2.1 displaystring read-write
Name of group 2 - User configurable, 16 characters
             group2TempName 1.3.6.1.4.1.16174.1.1.3.3.2.2 displaystring read-write
Name of Temperature probe in group 2 - User configurable, 16 characters
             group2TempDataStr 1.3.6.1.4.1.16174.1.1.3.3.2.3 displaystring read-write
Data from Temperature probe in group 2, string format, to 1 decimal place
             group2TempDataInt 1.3.6.1.4.1.16174.1.1.3.3.2.4 integer read-write
Data from Temperature probe in group 2, integer format, no decimal places
             group2HumidName 1.3.6.1.4.1.16174.1.1.3.3.2.5 displaystring read-write
Name of Humidity probe in group 2 - User configurable, 16 characters
             group2HumidDataStr 1.3.6.1.4.1.16174.1.1.3.3.2.6 displaystring read-write
Data from Humidity probe in group 2, string format, to 1 decimal place
             group2HumidDataInt 1.3.6.1.4.1.16174.1.1.3.3.2.7 integer read-write
Data from Humidity probe in group 2, integer format, no decimal places
             group2WetName 1.3.6.1.4.1.16174.1.1.3.3.2.8 displaystring read-write
Name of Wetness probe in group 2 - User configurable, 16 characters
             group2WetDataStr 1.3.6.1.4.1.16174.1.1.3.3.2.9 displaystring read-write
Data from Wetness probe in group 2, string format, to 1 decimal place
             group2WetDataInt 1.3.6.1.4.1.16174.1.1.3.3.2.10 integer read-write
Data from Wetness probe in group 2, integer format, no decimal places
         group3 1.3.6.1.4.1.16174.1.1.3.3.3
             group3Name 1.3.6.1.4.1.16174.1.1.3.3.3.1 displaystring read-write
Name of group 3 - User configurable, 16 characters
             group3TempName 1.3.6.1.4.1.16174.1.1.3.3.3.2 displaystring read-write
Name of Temperature probe in group 3 - User configurable, 16 characters
             group3TempDataStr 1.3.6.1.4.1.16174.1.1.3.3.3.3 displaystring read-write
Data from Temperature probe in group 3, string format, to 1 decimal place
             group3TempDataInt 1.3.6.1.4.1.16174.1.1.3.3.3.4 integer read-write
Data from Temperature probe in group 3, integer format, no decimal places
             group3HumidName 1.3.6.1.4.1.16174.1.1.3.3.3.5 displaystring read-write
Name of Humidity probe in group 3 - User configurable, 16 characters
             group3HumidDataStr 1.3.6.1.4.1.16174.1.1.3.3.3.6 displaystring read-write
Data from Humidity probe in group 3, string format, to 1 decimal place
             group3HumidDataInt 1.3.6.1.4.1.16174.1.1.3.3.3.7 integer read-write
Data from Humidity probe in group 3, integer format, no decimal places
             group3WetName 1.3.6.1.4.1.16174.1.1.3.3.3.8 displaystring read-write
Name of Wetness probe in group 3 - User configurable, 16 characters
             group3WetDataStr 1.3.6.1.4.1.16174.1.1.3.3.3.9 displaystring read-write
Data from Wetness probe in group 3, string format, to 1 decimal place
             group3WetDataInt 1.3.6.1.4.1.16174.1.1.3.3.3.10 integer read-write
Data from Wetness probe in group 3, integer format, no decimal places
         group4 1.3.6.1.4.1.16174.1.1.3.3.4
             group4Name 1.3.6.1.4.1.16174.1.1.3.3.4.1 displaystring read-write
Name of group 4 - User configurable, 16 characters
             group4TempName 1.3.6.1.4.1.16174.1.1.3.3.4.2 displaystring read-write
Name of Temperature probe in group 4 - User configurable, 16 characters
             group4TempDataStr 1.3.6.1.4.1.16174.1.1.3.3.4.3 displaystring read-write
Data from Temperature probe in group 4, string format, to 1 decimal place
             group4TempDataInt 1.3.6.1.4.1.16174.1.1.3.3.4.4 integer read-write
Data from Temperature probe in group 4, integer format, no decimal places
             group4HumidName 1.3.6.1.4.1.16174.1.1.3.3.4.5 displaystring read-write
Name of Humidity probe in group 4 - User configurable, 16 characters
             group4HumidDataStr 1.3.6.1.4.1.16174.1.1.3.3.4.6 displaystring read-write
Data from Humidity probe in group 4, string format, to 1 decimal place
             group4HumidDataInt 1.3.6.1.4.1.16174.1.1.3.3.4.7 integer read-write
Data from Humidity probe in group 4, integer format, no decimal places
             group4WetName 1.3.6.1.4.1.16174.1.1.3.3.4.8 displaystring read-write
Name of Wetness probe in group 4 - User configurable, 16 characters
             group4WetDataStr 1.3.6.1.4.1.16174.1.1.3.3.4.9 displaystring read-write
Data from Wetness probe in group 4, string format, to 1 decimal place
             group4WetDataInt 1.3.6.1.4.1.16174.1.1.3.3.4.10 integer read-write
Data from Wetness probe in group 4, integer format, no decimal places