Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 psMonitored 1.3.6.1.4.1.5591.1.4.1 integer read-only
Number of power supply connected to this NE.
 psDeviceTable 1.3.6.1.4.1.5591.1.4.2 no-access
Table containing information about the individual power supplies being monitored
     psDeviceEntry 1.3.6.1.4.1.5591.1.4.2.1 no-access
List of information about each power supply being monitored.
         psDeviceAddress 1.3.6.1.4.1.5591.1.4.2.1.1 integer read-only
Index into the psDeviceTable.Address of this device on the RS-485 path
         psProtocolVersion 1.3.6.1.4.1.5591.1.4.2.1.2 integer read-only
Version of the SCTE HMS protocol implemented in the monitored equipment. The 'Protocol Version' implementation will comply with the defined protocol in the SCTE 25-3 (formerly HMS 022) document with the corresponding revision number. Example: A power supply implementing all commands and responses defined in SCTE 25-3 (formerly HMS 022) would return a value of 10 (decimal) in this field, reflecting major revision 1, minor revision 0. Any number returned that is less than 10 reflects a version of the SCTE 25-3 specification that had not yet been approved by SCTE.
         psSoftwareVersion 1.3.6.1.4.1.5591.1.4.2.1.3 displaystring read-only
The content of this field is vendor specific. The intent is to provide a text representation of the power supply or generator system software version. Any printable ASCII characters can be included in this field. NULL (0x00) characters are non-printable and are used to fill any unused locations following the text data
         psDeviceId 1.3.6.1.4.1.5591.1.4.2.1.4 octet string read-only
The content of this field is vendor specific. The intent is to provide manufacturer and/or product specific ASCII text information that will propagate to the manager's console verbatim. The following special characters are defined in association with this field:'\' Used to cause a new line on the console display. Example: 'ALPHA\XM2 9015' would appear at the monitoring station as : ALPHA XM2 9015
         psBatteries 1.3.6.1.4.1.5591.1.4.2.1.5 integer read-only
Current number of batteries per battery string.
         psBatteryStrings 1.3.6.1.4.1.5591.1.4.2.1.6 integer read-only
Current number of battery strings.
         psTempSensors 1.3.6.1.4.1.5591.1.4.2.1.7 integer read-only
Number of Battery temperature sensors.
         psOutputs 1.3.6.1.4.1.5591.1.4.2.1.8 integer read-only
Number of power supply outputs.
         psBatteryCurrentSupport 1.3.6.1.4.1.5591.1.4.2.1.9 integer read-only
Bit Map that defines if battery current is measured in this installation. Bit set means this particular string supports this measurement. Bits Addresses 0 Not used 1 1 String 1 has battery current support 2 2 String 2 has battery current support 3 3 String 3 has battery current support 4 4 String 4 has battery current support . . .................................... . . .................................... . . .................................... n n String n has battery current support
         psFloatCurrentSupport 1.3.6.1.4.1.5591.1.4.2.1.10 integer read-only
Bit Map that defines if float current is measured in this installation. Bit set means this particular string supports this measurement. Bits Addresses 0 Not used 1 1 String 1 has float current support 2 2 String 2 has float current support 3 3 String 3 has float current support 4 4 String 4 has float current support . . .................................. . . .................................. . . .................................. n n String n has float current support
         psOutputVoltageSupport 1.3.6.1.4.1.5591.1.4.2.1.11 integer read-only
Defines if power supply supports monitoring of output voltage 1 = No support. Discard associated value in Get_Power_Supply_Data response. 2 = Field is supported in this installation. Enumeration: 'none': 1, 'supported': 2.
         psInputVoltageSupport 1.3.6.1.4.1.5591.1.4.2.1.12 integer read-only
Defines if power supply supports monitoring of input or line voltage 1 = No support. Discard associated value in Get_Power_Supply_Data response. 2 = Field is supported - value in psInputVoltagePresence. 3 = Field is supported - analog representation. value in psInputVoltage. Enumeration: 'binary': 2, 'none': 1, 'analog': 3.
         psPowerSupplyTest 1.3.6.1.4.1.5591.1.4.2.1.13 integer read-only
Defines if power supply supports the remote test feature: 1 = Function not supported. 2 - Function is supported. Enumeration: 'none': 1, 'supported': 2.
         psMajorAlarmSupport 1.3.6.1.4.1.5591.1.4.2.1.14 integer read-only
Defines if the power supply supports the major alarm indicator: 1 = No support. Discard associated value in Get_Power_Supply_Data response. 2 = Field is supported in this installation. Enumeration: 'none': 1, 'supported': 2.
         psMinorAlarmSupport 1.3.6.1.4.1.5591.1.4.2.1.15 integer read-only
Defines if the power supply supports the minor alarm indicator: 1 = No support. Discard associated value in Get_Power_Supply_Data response. 2 = Field is supported in this installation. Enumeration: 'none': 1, 'supported': 2.
         psTamperSupport 1.3.6.1.4.1.5591.1.4.2.1.16 integer read-only
Defines if the enclosure door switch is installed in this location: 1 = No support. Discard associated value in Get_Power_Supply_Data response. 2 = Field is supported in this installation. Enumeration: 'none': 1, 'supported': 2.
         psBatteryVoltageSupport 1.3.6.1.4.1.5591.1.4.2.1.17 integer read-only
Defines the if batteries or string voltage are available: 1 = No battery voltage monitoring is available. 2 = Only full string battery voltage is available. 3 = Both individual battery and full string voltages are available. Enumeration: 'both': 3, 'totalString': 2, 'noMonitoring': 1.
         psOutputPowerSupport 1.3.6.1.4.1.5591.1.4.2.1.18 integer read-only
Defines if the output power measurement is supported 1 = No support. Discard associated value in Get_Power_Supply_Data response. 2 = Field is supported in this installation. Enumeration: 'none': 1, 'supported': 2.
         psOutputFrequencySupport 1.3.6.1.4.1.5591.1.4.2.1.19 integer read-only
Defines if the output frequency measurement is supported 1 = No support. Discard associated value in Get_Power_Supply_Data response. 2 = Field is supported in this installation. Enumeration: 'none': 1, 'supported': 2.
         psInputCurrentSupport 1.3.6.1.4.1.5591.1.4.2.1.20 integer read-only
Defines if the input current measurement is supported 1 = No support. Discard associated value in Get_Power_Supply_Data response. 2 = Field is supported in this installation. Enumeration: 'none': 1, 'supported': 2.
         psInputPowerSupport 1.3.6.1.4.1.5591.1.4.2.1.21 integer read-only
Defines if the input power measurement is supported 1 = No support. Discard associated value in Get_Power_Supply_Data response. 2 = Field is supported in this installation. Enumeration: 'none': 1, 'supported': 2.
         psOutputVoltage 1.3.6.1.4.1.5591.1.4.2.1.22 integer read-only
Power supply output voltage in 1/100 Volts units. This RMS value is common for all outputs in a multiple output system. This item requires an entry in the properties MIB
         psInputVoltage 1.3.6.1.4.1.5591.1.4.2.1.23 integer read-only
Scaled representation of input 'line' or 'grid' voltage. This is an RMS value in 1/100 Volts units. This item requires an entry in the properties MIB.
         psInverterStatus 1.3.6.1.4.1.5591.1.4.2.1.24 integer read-only
Status of power supply inverter. Enumerated value indicates current status of inverter. 1 = OFF, 2 = ON: AC Line Fail, 3 = ON: Local Test Cycle, 4 = ON: Remote test initiated 5 = ALARM: Last Test Failed This item requires entries in the discrete properties MIB. Enumeration: 'testStarted': 4, 'testFailed': 5, 'off': 1, 'lineFail': 2, 'testCycle': 3.
         psMajorAlarm 1.3.6.1.4.1.5591.1.4.2.1.25 integer read-only
Service has been dropped or a service interruption is imminent. Indicates that an immediate truck roll is appropriate. Specific alarms and alarm nomenclature varies between vendors. Vendors should disclose all conditions that contribute to this alarm in appropriate product literature. 1 = OK, 2 = ALARM. This item requires entries in the discrete properties MIB. Enumeration: 'alarm': 2, 'noAlarm': 1.
         psMinorAlarm 1.3.6.1.4.1.5591.1.4.2.1.26 integer read-only
A non-service effecting condition has occurred and should be monitored. Specific alarms and alarm nomenclature varies between vendors. Vendors should disclose all conditions that contribute to this alarm in appropriate product literature. 1 = OK, 2 = ALARM This item requires entries in the discrete properties MIB. Enumeration: 'alarm': 2, 'noAlarm': 1.
         psTamper 1.3.6.1.4.1.5591.1.4.2.1.27 integer read-only
Indicates status of enclosure door. This notification is NOT included in the 'Major' or 'Minor' alarm fields. Individual users / installations must determine if a door open status represents an alarm and if so, of what severity. 1 = CLOSED, 2 = OPEN This item requires entries in the discrete properties MIB. Enumeration: 'open': 2, 'closed': 1.
         psTotalStringVoltage 1.3.6.1.4.1.5591.1.4.2.1.28 integer read-only
Scaled representation of the full battery string in 1/100 Volts units. This item requires an entry in the properties MIB.
         psEquipmentControl 1.3.6.1.4.1.5591.1.4.2.1.29 integer read-write
Equipment control 1 = Discontinue inverter operation, 2 = Begin inverter operation Enumeration: 'startTest': 2, 'stopTest': 1.
         psPowerOut 1.3.6.1.4.1.5591.1.4.2.1.30 integer read-only
Representation of power supply output power in 1 W. This item requires an entry in the properties MIB.
         psFrequencyOut 1.3.6.1.4.1.5591.1.4.2.1.31 integer read-only
Scaled representation of the power supply output frequency in 1/100 Hz. This item requires an entry in the properties MIB.
         psRMSCurrentIn 1.3.6.1.4.1.5591.1.4.2.1.32 integer read-only
Scaled representation of the power supply RMS input current in 1/100 A. This item requires an entry in the properties MIB.
         psPowerIn 1.3.6.1.4.1.5591.1.4.2.1.33 integer read-only
Representation of the power supply input power in 1 W. This item requires an entry in the properties MIB.
         psInputVoltagePresence 1.3.6.1.4.1.5591.1.4.2.1.34 integer read-only
Digital value indicating that line voltage is present and within tolerance or not. 1 = lost 2 = ok. This item requires entries in the discrete properties MIB. Enumeration: 'ok': 2, 'lost': 1.
         psFrequencyIn 1.3.6.1.4.1.5591.1.4.2.1.35 integer read-only
Operational frequency for input voltage Enumeration: 'sixtyHz': 2, 'fiftyHz': 1.
 psStringTable 1.3.6.1.4.1.5591.1.4.3 no-access
Table containing strings data
     psStringEntry 1.3.6.1.4.1.5591.1.4.3.1 no-access
List of information about each string. Indexed by device and string number
         psStringDeviceAddress 1.3.6.1.4.1.5591.1.4.3.1.1 integer read-only
Index into the psStringTable. Corresponds to psDeviceAddress in psDeviceTable.
         psString 1.3.6.1.4.1.5591.1.4.3.1.2 integer read-only
Index into the psStringTable.
         psStringChargeCurrent 1.3.6.1.4.1.5591.1.4.3.1.3 integer read-only
Scaled representation of battery string charge current. This is an RMS value in 1/100 Amps. When batteries being discharged, this value will = 0. This item requires an entry in the properties MIB.
         psStringDischargeCurrent 1.3.6.1.4.1.5591.1.4.3.1.4 integer read-only
Scaled representation of battery string discharge current. This is an RMS value in 1/100 Amps.If multiple strings are installed but only one measurement sensor is used, this value represents the total battery discharge current. When batteries are being charged, this value will = 0. This item requires an entry in the properties MIB.
         psStringFloat 1.3.6.1.4.1.5591.1.4.3.1.5 integer read-only
Scaled representation of battery 'float' charge current in 1/100 Amps. This field will be '0' under conditions other than during actual float charging. When this field is non-zero (reporting float current), other battery current values (charge and discharge) should be discarded. If multiple strings are installed but only one measurement sensor is used, this field represents the total float current. This item requires an entry in the properties MIB.
 psBatteryTable 1.3.6.1.4.1.5591.1.4.4 no-access
Table containing batteries voltages
     psBatteryEntry 1.3.6.1.4.1.5591.1.4.4.1 no-access
List of information about each battery.Indexed by device number and string
         psBatteryDeviceAddress 1.3.6.1.4.1.5591.1.4.4.1.1 integer read-only
Index into the psBatteryTable. Corresponds to psDeviceAddress in psDeviceTable.
         psBatteryString 1.3.6.1.4.1.5591.1.4.4.1.2 integer read-only
Index into the psBatteryTable. Corresponds to psString in psStringTable.
         psBattery 1.3.6.1.4.1.5591.1.4.4.1.3 integer read-only
Index into the psBatteryTable.
         psBatteryVoltage 1.3.6.1.4.1.5591.1.4.4.1.4 integer read-only
Scaled representation of an individual battery voltage in 1/100 Volts. String 'A' is used if only one battery string is active. This item requires an entry in the properties MIB.
 psOutputTable 1.3.6.1.4.1.5591.1.4.5 no-access
Table containing output currents
     psOutputEntry 1.3.6.1.4.1.5591.1.4.5.1 no-access
List of information about each Output port. Indexed by device and port number
         psOutputDeviceAddress 1.3.6.1.4.1.5591.1.4.5.1.1 integer read-only
Index into the psOutputTable.Corresponds to psDeviceAddress in psDeviceTable.
         psOutput 1.3.6.1.4.1.5591.1.4.5.1.2 integer read-only
Index into the psOutputTable. Output number
         psOutputCurrent 1.3.6.1.4.1.5591.1.4.5.1.3 integer read-only
Scaled representation of power supply RMS output current in 1/100 Amps. This value is the total power supply output current if only one output is active. If multiple outputs are active, this value represents output #1 current. This item requires an entry in the properties MIB.
 psTemperatureSensorTable 1.3.6.1.4.1.5591.1.4.6 no-access
Table containing temperature sensors information
     psTemperatureSensorEntry 1.3.6.1.4.1.5591.1.4.6.1 no-access
List of information about each Temperature sensor. Indexed by device and Sensor number
         psTempDeviceAddress 1.3.6.1.4.1.5591.1.4.6.1.1 integer read-only
Index into the psTemperatureSensorTable.Corresponds to psDeviceAddress in psDeviceTable.
         psTemperatureSensor 1.3.6.1.4.1.5591.1.4.6.1.2 integer read-only
Index into the psTemperatureSensorTable. Temperature sensor number
         psTemperature 1.3.6.1.4.1.5591.1.4.6.1.3 integer read-only
Scaled representation of temperature. in degrees C with a range of -40 to + 80 degrees C. This item requires an entry in the properties MIB.