SC5002-MIB: View SNMP OID List / Download MIB

VENDOR: GENERAL DATACOMM


 Home MIB: SC5002-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 gdc 1.3.6.1.4.1.498
         dsx1 1.3.6.1.4.1.498.6
             sc5002 1.3.6.1.4.1.498.6.8
                 sc5002Version 1.3.6.1.4.1.498.6.8.1
                     sc5002MIBversion 1.3.6.1.4.1.498.6.8.1.1 displaystring read-only
Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Upon formal release, no designation for the test revision will be present. Acceptable values for the individual revision components are as follows: x: 1 - 9, y: 0 - 9, z: 0 - 9, T: A - Z
                     sc5002VersionTable 1.3.6.1.4.1.498.6.8.1.2 no-access
                         sc5002VersionEntry 1.3.6.1.4.1.498.6.8.1.2.1 no-access
An entry in the GDC SC5002 Version Table.
                             sc5002VersionIndex 1.3.6.1.4.1.498.6.8.1.2.1.1 scinstance read-only
Identifies Version parameters associated with the managed object.
                             sc5002ActiveFirmwareRev 1.3.6.1.4.1.498.6.8.1.2.1.2 displaystring read-only
The version number of the firmware currently executing. The format is MM.NN.BB where: MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99)
                             sc5002StoredFirmwareRev 1.3.6.1.4.1.498.6.8.1.2.1.3 displaystring read-only
The version number of the firmware stored (in a compressed format) but not currently executing. MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99)
                             sc5002BootRev 1.3.6.1.4.1.498.6.8.1.2.1.4 displaystring read-only
The version number of the bootstrap firmware. The version number of the firmware, to allow products to know which revision is installed. The released version number is sequenced from --, A-, ... AA, ... ZZ.
                             sc5002StoredFirmwareStatus 1.3.6.1.4.1.498.6.8.1.2.1.5 integer read-only
This object represents the state of the Non-Active or Stored firmware: statBlank(1) Factory Default statDownLoading(2) In process of downloading firmware statOK(3) Zipped version checksum succesful (OK to switch) (can set sc5002SwitchActive to switchActive(2)) statCheckSumBad(4) Failed checksum after download statUnZipping(5) In process of uncompressing into active area statBadUnZip(6) Failed last uncompress The object is read only. Enumeration: 'statDownLoading': 2, 'statBadUnZip': 6, 'statBlank': 1, 'statOK': 3, 'statUnZipping': 5, 'statCheckSumBad': 4.
                             sc5002SwitchActiveFirmware 1.3.6.1.4.1.498.6.8.1.2.1.6 integer read-write
This object is used to switch the active executing firmware from the version in sc5002ActiveRev to the version in sc5002StoredRev. When a switchActive(2) is set (write only) the element will: 1) reboot 2) uncompress stored code into active area 3) perform checksum on active area 4) Set sc5002StoredStatus object to indicate results 5) If succesfull: update sc5002ActiveFirmwareRev and sc5002StoredFirmwareRev and begin executing If failed: replace active area with previous revision The switchNorm(1) enumeration will always be read. Setting switchActive(2) when the sc5002StoredStatus is not statOK(3) will result in an error. Enumeration: 'switchNorm': 1, 'switchActive': 2.
                             sc5002DownloadingMode 1.3.6.1.4.1.498.6.8.1.2.1.7 integer read-write
This object is used to configure the download mode: disableAll(1) Prevents any firmware downloading to SC5002 enableAndWait(2) Allows downloading zipped code to be stored only! enableAndSwitch(3) Allows downloading and then unzips and begins executing the new code Enumeration: 'enableAndSwitch': 3, 'enableAndWait': 2, 'disableAll': 1.
                             sc5002FirmwareRev 1.3.6.1.4.1.498.6.8.1.2.1.8 displaystring read-only
The version number of the firmware. Released versions are sequenced from --, A-, ... AA, ... ZZ. Test versions are from 01 to 99.
                 sc5002NetworkCfg 1.3.6.1.4.1.498.6.8.2
                     sc5002NetworkCfgTable 1.3.6.1.4.1.498.6.8.2.1 no-access
This table contains objects that support the specific management requirements for configuring the SC5002 Network Interface level objects.
                         sc5002NetworkCfgEntry 1.3.6.1.4.1.498.6.8.2.1.1 no-access
The sc5002 Network Configuration Table Entry.
                             sc5002NetworkCfgIndex 1.3.6.1.4.1.498.6.8.2.1.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002E1SignalingMode 1.3.6.1.4.1.498.6.8.2.1.1.2 integer read-write
Specifies the channel signaling scheme for the E1 network interface. Enumeration: 'assocChanSigNoCRC4': 2, 'assocChanSigWithCRC4': 1.
                 sc5002Alarms 1.3.6.1.4.1.498.6.8.3
                     sc5002AlarmData 1.3.6.1.4.1.498.6.8.3.1
                         sc5002NoResponse 1.3.6.1.4.1.498.6.8.3.1.1
                         sc5002DiagRxErr 1.3.6.1.4.1.498.6.8.3.1.2
                         sc5002PowerUp 1.3.6.1.4.1.498.6.8.3.1.3
                         sc5002NvRamCorrupt 1.3.6.1.4.1.498.6.8.3.1.4
                         sc5002UnitFailure 1.3.6.1.4.1.498.6.8.3.1.5
                         sc5002TimingLoss 1.3.6.1.4.1.498.6.8.3.1.6
                         sc5002LossOfSignal 1.3.6.1.4.1.498.6.8.3.1.7
                         sc5002LossOfFrame 1.3.6.1.4.1.498.6.8.3.1.8
                         sc5002AlarmIndSignal 1.3.6.1.4.1.498.6.8.3.1.9
                         sc5002FallbackTimingActive 1.3.6.1.4.1.498.6.8.3.1.10
                         sc5002NearEndLnCodeViol 1.3.6.1.4.1.498.6.8.3.1.11
                         sc5002NearEndErrSec 1.3.6.1.4.1.498.6.8.3.1.12
                         sc5002NearEndBkdBlkErr 1.3.6.1.4.1.498.6.8.3.1.13
                         sc5002NearEndSevErrSec 1.3.6.1.4.1.498.6.8.3.1.14
                         sc5002NearEndUnavlSec 1.3.6.1.4.1.498.6.8.3.1.15
                         sc5002FarEndErrSec 1.3.6.1.4.1.498.6.8.3.1.16
                         sc5002FarEndBkdBlkErr 1.3.6.1.4.1.498.6.8.3.1.17
                         sc5002FarEndSevErrSec 1.3.6.1.4.1.498.6.8.3.1.18
                         sc5002FarEndUnavlSec 1.3.6.1.4.1.498.6.8.3.1.19
                     sc5002NearEndAlarmCfgTable 1.3.6.1.4.1.498.6.8.3.2 no-access
This table contains entries that configure Near End Alarm reporting.
                         sc5002NearEndAlarmCfgEntry 1.3.6.1.4.1.498.6.8.3.2.1 no-access
An entry in the Near End Alarm Configuration table.
                             sc5002NearEndAlarmCfgIndex 1.3.6.1.4.1.498.6.8.3.2.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002NearEndAlarmCfgIdentifier 1.3.6.1.4.1.498.6.8.3.2.1.2 object identifier read-only
format: iso.org.dod.internet.private.enterprises.gdc. dsx1.sc5002.sc5002Alarms.sc5002AlarmData.ALM example: 1.3.6.1.4.1.498.6.8.4.1.ALM where ALM = 1 for sc5002NoResponse alarm, 2 for sc5002DiagRxErr alarm, etc., as specified in the Alarm Definitions above.
                             sc5002NearEndAlarmWindow 1.3.6.1.4.1.498.6.8.3.2.1.3 integer read-write
The time period in which a specified number of events must occur, (specified by the alarm's threshold), before declaring an alarm condition. After reporting an Alarm condition and upon expiration of the window time period, the event count is reset to zero and another time period is begun. If the specified number of events is not exceeded within the next time period, an Alarm Cleared condition is reported. Enumeration: 'win1min': 2, 'win1hr': 4, 'win15min': 3, 'win24hr': 5, 'win30sec': 1.
                             sc5002NearEndAlarmThreshold 1.3.6.1.4.1.498.6.8.3.2.1.4 integer read-write
The number of events which must be exceed, within the time period specified by the alarm's window, before declaring an alarm Enumeration: 'thr10000': 6, 'thr10': 3, 'thr1000': 5, 'thr100': 4, 'thr3': 2, 'thr1': 1.
                     sc5002FarEndAlarmCfgTable 1.3.6.1.4.1.498.6.8.3.3 no-access
This table contains entries that configure Far End Alarm reporting.
                         sc5002FarEndAlarmCfgEntry 1.3.6.1.4.1.498.6.8.3.3.1 no-access
An entry in the Far End Alarm Configuration table.
                             sc5002FarEndAlarmCfgIndex 1.3.6.1.4.1.498.6.8.3.3.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002FarEndAlarmCfgIdentifier 1.3.6.1.4.1.498.6.8.3.3.1.2 object identifier read-only
format: iso.org.dod.internet.private.enterprises.gdc. dsx1.sc5002.sc5002Alarms.sc5002AlarmData.ALM example: 1.3.6.1.4.1.498.6.8.4.1.ALM where ALM = 1 for sc5002NoResponse alarm, 2 for sc5002DiagRxErr alarm, etc., as specified in the Alarm Definitions above.
                             sc5002FarEndAlarmWindow 1.3.6.1.4.1.498.6.8.3.3.1.3 integer read-write
The time period in which a specified number of events must occur, (specified by the alarm's threshold), before declaring an alarm condition. After reporting an Alarm condition and upon expiration of the window time period, the event count is reset to zero and another time period is begun. If the specified number of events is not exceeded within the next time period, an Alarm Cleared condition is reported. Enumeration: 'win1min': 2, 'win1hr': 4, 'win15min': 3, 'win24hr': 5, 'win30sec': 1.
                             sc5002FarEndAlarmThreshold 1.3.6.1.4.1.498.6.8.3.3.1.4 integer read-write
The number of events which must be exceed, within the time period specified by the alarm's window, before declaring an alarm Enumeration: 'thr10000': 6, 'thr10': 3, 'thr1000': 5, 'thr100': 4, 'thr3': 2, 'thr1': 1.
                 sc5002Diagnostics 1.3.6.1.4.1.498.6.8.4
                     sc5002DiagTable 1.3.6.1.4.1.498.6.8.4.1 no-access
The GDC 5002 Diagnostics table. Information in the entries of this table support diagnostics testing, both active testing via patterns, and passive testing via loopbacks.
                         sc5002DiagEntry 1.3.6.1.4.1.498.6.8.4.1.1 no-access
The GDC 5002 Diagnostics table entry.
                             sc5002DiagIndex 1.3.6.1.4.1.498.6.8.4.1.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002LoopbackConfig 1.3.6.1.4.1.498.6.8.4.1.1.2 integer read-write
Selects the test to run. A get of this object returns the test that is currently running. A set of noLoopBack(1) ends the test that is currently running. A set of lineLoopBack(2) starts a line loop back test. The line loop back test runs until a set of noLoopBack(1) is sent. A set of unitTest(3) starts a unit test. The unit test runs for 15 seconds. Enumeration: 'unitTest': 3, 'noLoopBack': 1, 'lineLoopBack': 2.
                             sc5002TestResult 1.3.6.1.4.1.498.6.8.4.1.1.3 integer read-only
The results of the last diagnostic test completed. The value returned is only valid if a get of sc5002LoopbackConfig returns noLoopBack(1). Enumeration: 'fail': 2, 'pass': 1.
                 sc5002Maintenance 1.3.6.1.4.1.498.6.8.5
                     sc5002MaintenanceTable 1.3.6.1.4.1.498.6.8.5.1 no-access
The table describes the maintenance objects for the unit and references the unit interface (cc = 00).
                         sc5002MaintenanceEntry 1.3.6.1.4.1.498.6.8.5.1.1 no-access
An entry in the GDC E1 Maintenance Table.
                             sc5002MaintenanceLineIndex 1.3.6.1.4.1.498.6.8.5.1.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002SoftReset 1.3.6.1.4.1.498.6.8.5.1.1.2 integer read-write
Supports the action of soft resetting the unit. When this object is set to reset(1), then the unit performs a soft reset, whose meaning is specific to the type of unit being managed. The value of norm(2) will be returned when the reset is complete. The value of norm(2) can not be set by management. Enumeration: 'reset': 1, 'norm': 2.
                             sc5002DefaultInit 1.3.6.1.4.1.498.6.8.5.1.1.3 integer read-write
This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(1) the unit will perform a reset to make the default configuration take effect. The value of normal(2) will be returned when the initialization is complete. The value of normal(2) can not be set by management. Enumeration: 'normal': 2, 'factoryDefault': 1.
                             sc5002NearEndResetStats 1.3.6.1.4.1.498.6.8.5.1.1.4 integer read-write
Supports the action of soft resetting the sc5002NearEndValidIntervals object. When this object is set to reset(2), then the unit will reset the sc5002ValidIntervals object to zero. The value of norm(1) can not be set by management. Enumeration: 'reset': 2, 'norm': 1.
                             sc5002NearEndStatLastInitialized 1.3.6.1.4.1.498.6.8.5.1.1.5 integer read-only
Number of seconds from midnight Dec 31, 1969 up until sc5002NearEndValidIntervals was last initialized to zero
                             sc5002FarEndResetStats 1.3.6.1.4.1.498.6.8.5.1.1.6 integer read-write
Supports the action of soft resetting the sc5002FarEndValidIntervals object. When this object is set to reset(2), then the unit will reset the sc5002ValidIntervals object to zero. The value of norm(1) can not be set by management. Enumeration: 'reset': 2, 'norm': 1.
                             sc5002FarEndStatLastInitialized 1.3.6.1.4.1.498.6.8.5.1.1.7 integer read-only
Number of seconds from midnight Dec 31, 1969 up until sc5002FarEndValidIntervals was last initialized to zero
                             sc5002LedStatus 1.3.6.1.4.1.498.6.8.5.1.1.8 octet string read-only
Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit 2 - NIU bit 1 - D_I bit 0 - future use Octet 2 bit 7 - not used bit 6 - future use bit 5 - NTWK AIS bit 4 - NTWK LCV bit 3 - NTWK LOS bit 2 - NTWK OOF bit 1 - ALM bit 0 - TM Octet 3 bit 7 - not used bit 6 - ST- future use bit 5 - LT- future use bit 4 - RL- future use bit 3 - TM transitions/flashing bit 2 - future use bit 1 - future use bit 0 - future use
                             sc5002NearEndValidIntervals 1.3.6.1.4.1.498.6.8.5.1.1.9 integer read-only
The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online.
                             sc5002FarEndValidIntervals 1.3.6.1.4.1.498.6.8.5.1.1.10 integer read-only
The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online.
                             sc5002SysUpTime 1.3.6.1.4.1.498.6.8.5.1.1.11 integer read-only
This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count.
                 sc5002Performance 1.3.6.1.4.1.498.6.8.6
                     sc5002NearEndCurrent15MinTable 1.3.6.1.4.1.498.6.8.6.1 no-access
The sc5002 Current table.
                         sc5002NearEndCurrent15MinEntry 1.3.6.1.4.1.498.6.8.6.1.1 no-access
An entry in the sc5002 NearEnd Current table.
                             sc5002NearEndCurrent15MinIndex 1.3.6.1.4.1.498.6.8.6.1.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002NearEndCurrent15MinStat 1.3.6.1.4.1.498.6.8.6.1.1.2 octet string read-only
Returns a bitwise snapshot of the current 15Min statistics. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 -- 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 Counter Overflow (>65535) LCV 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 LCV . 11.0 2^7 12.7 f/u 12.6 2^6 LCV . 12.0 2^0
                     sc5002NearEndIntervalTable 1.3.6.1.4.1.498.6.8.6.2 no-access
The sc5002 Interval table.
                         sc5002NearEndIntervalEntry 1.3.6.1.4.1.498.6.8.6.2.1 no-access
An entry in the E1 Interval table.
                             sc5002NearEndIntervalIndex 1.3.6.1.4.1.498.6.8.6.2.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002NearEndIntervalNumber 1.3.6.1.4.1.498.6.8.6.2.1.2 integer read-only
The number of Errored Seconds encountered by an E1 interface in one of the previous 16, individual 15 minute, intervals.
                             sc5002NearEndIntervalStat 1.3.6.1.4.1.498.6.8.6.2.1.3 octet string read-only
Returns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 -- 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 Counter Overflow (>65535) LCV 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 LCV . 11.0 2^7 12.7 f/u 12.6 2^6 LCV . 12.0 2^0
                     sc5002NearEndCurrent24HrTable 1.3.6.1.4.1.498.6.8.6.3 no-access
The E1 Current24Hr table. 4 hour interval.
                         sc5002NearEndCurrent24HrEntry 1.3.6.1.4.1.498.6.8.6.3.1 no-access
An entry in the E1 Total table.
                             sc5002NearEndCurrent24HrIndex 1.3.6.1.4.1.498.6.8.6.3.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002NearEndCurrent24HrStat 1.3.6.1.4.1.498.6.8.6.3.1.2 octet string read-only
Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 -- 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 13.7 f/u 13.6 f/u 13.5 f/u 13.4 f/u 13.3 f/u 13.2 1: Counter Overflow (>65535) LCV 13.1 2^15 13.0 2^14 14.7 f/u 14.6 2^13 LCV . 14.0 2^7 15.7 f/u 15.6 2^6 LCV . 15.0 2^0
                     sc5002NearEndRecent24HrTable 1.3.6.1.4.1.498.6.8.6.4 no-access
The E1 Recent24Hr table. 4 hour interval.
                         sc5002NearEndRecent24HrEntry 1.3.6.1.4.1.498.6.8.6.4.1 no-access
An entry in the E1 Total table.
                             sc5002NearEndRecent24HrIndex 1.3.6.1.4.1.498.6.8.6.4.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002NearEndRecent24HrStat 1.3.6.1.4.1.498.6.8.6.4.1.2 octet string read-only
Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 -- 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 13.7 f/u 13.6 f/u 13.5 f/u 13.4 f/u 13.3 f/u 13.2 1: Counter Overflow (>65535) LCV 13.1 2^15 13.0 2^14 14.7 f/u 14.6 2^13 LCV . 14.0 2^7 15.7 f/u 15.6 2^6 LCV . 15.0 2^0
                     sc5002FarEndCurrent15MinTable 1.3.6.1.4.1.498.6.8.6.5 no-access
The sc5002FarEnd Current 15 minute table.
                         sc5002FarEndCurrent15MinEntry 1.3.6.1.4.1.498.6.8.6.5.1 no-access
An entry in the sc5002FarEnd Current 15 Minute table.
                             sc5002FarEndCurrent15MinIndex 1.3.6.1.4.1.498.6.8.6.5.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002FarEndCurrent15MinStat 1.3.6.1.4.1.498.6.8.6.5.1.2 octet string read-only
Returns a bitwise map of the far end interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 -- 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0
                     sc5002FarEndIntervalTable 1.3.6.1.4.1.498.6.8.6.6 no-access
The sc5002FarEnd Interval table.
                         sc5002FarEndIntervalEntry 1.3.6.1.4.1.498.6.8.6.6.1 no-access
An entry in the Interval table.
                             sc5002FarEndIntervalIndex 1.3.6.1.4.1.498.6.8.6.6.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002FarEndIntervalNumber 1.3.6.1.4.1.498.6.8.6.6.1.2 integer read-only
A number between 1 and 16, where 1 is the most recently completed 15 minute interval and 16 is the least recently completed 15 minutes interval (assuming that all 16 intervals are valid).
                             sc5002FarEndIntervalStat 1.3.6.1.4.1.498.6.8.6.6.1.3 octet string read-only
Returns a bitwise map of statistics for the far end interface in the current 15 minute interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0
                     sc5002CurrentFarEnd24HrTable 1.3.6.1.4.1.498.6.8.6.7 no-access
The Current 24 Hour table.
                         sc5002CurrentFarEnd24HrEntry 1.3.6.1.4.1.498.6.8.6.7.1 no-access
An entry in the Current 24 Hr table.
                             sc5002CurrentFarEnd24HrIndex 1.3.6.1.4.1.498.6.8.6.7.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002CurrentFarEnd24HrStat 1.3.6.1.4.1.498.6.8.6.7.1.2 octet string read-only
Returns a bitwise map of statistics for the interface in the current 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 -- 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0
                     sc5002RecentFarEnd24HrTable 1.3.6.1.4.1.498.6.8.6.8 no-access
The Recent 24 Hour table.
                         sc5002RecentFarEnd24HrEntry 1.3.6.1.4.1.498.6.8.6.8.1 no-access
An entry in the Recent 24 Hr table.
                             sc5002RecentFarEnd24HrIndex 1.3.6.1.4.1.498.6.8.6.8.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002RecentFarEnd24HrStat 1.3.6.1.4.1.498.6.8.6.8.1.2 octet string read-only
Returns a bitwise map of statistics for the interface in the Recent 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0
                     sc5002NearEndUnavailableTimeRegTable 1.3.6.1.4.1.498.6.8.6.9 no-access
The sc5002 Unavailable Time Register table.
                         sc5002NearEndUnavailableTimeRegEntry 1.3.6.1.4.1.498.6.8.6.9.1 no-access
An entry in the Unavailable Time Register table.
                             sc5002NearEndUnavailableTimeRegIndex 1.3.6.1.4.1.498.6.8.6.9.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                             sc5002NearEndUnavailableTimeRegNumber 1.3.6.1.4.1.498.6.8.6.9.1.2 integer read-only
A number between 1 and 6, where the number is the number of the Unavailable Time Register.
                             sc5002NearEndUnavailableTimeRegStart 1.3.6.1.4.1.498.6.8.6.9.1.3 integer read-only
Start time of one of the Unavailable Time Registers.
                             sc5002NearEndUnavailableTimeRegStop 1.3.6.1.4.1.498.6.8.6.9.1.4 integer read-only
Stop time of one of the Unavailable Time Registers.
                     sc5002FarEndUnavailableTimeRegTable 1.3.6.1.4.1.498.6.8.6.10 no-access
The sc5002 Unavailable Time Register table.
                           sc5002FarEndUnavailableTimeRegEntry 1.3.6.1.4.1.498.6.8.6.10.1 no-access
An entry in the Unavailable Time Register table.
                               sc5002FarEndUnavailableTimeRegIndex 1.3.6.1.4.1.498.6.8.6.10.1.1 scinstance read-only
Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)
                               sc5002FarEndUnavailableTimeRegNumber 1.3.6.1.4.1.498.6.8.6.10.1.2 integer read-only
A number between 1 and 6, where the number is the number of the Unavailable Time Register.
                               sc5002FarEndUnavailableTimeRegStart 1.3.6.1.4.1.498.6.8.6.10.1.3 integer read-only
Start time of one of the Unavailable Time Registers.
                               sc5002FarEndUnavailableTimeRegStop 1.3.6.1.4.1.498.6.8.6.10.1.4 integer read-only
Stop time of one of the Unavailable Time Registers.