RackMonitor-MIB: View SNMP OID List / Download MIB

VENDOR: EATON CORPORATION


 Home MIB: RackMonitor-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 powerware 1.3.6.1.4.1.534
         product 1.3.6.1.4.1.534.6
             dataCenter 1.3.6.1.4.1.534.6.7
                 environmentalMonitor 1.3.6.1.4.1.534.6.7.1
                     insObjects 1.3.6.1.4.1.534.6.7.1.1
                         rmIdent 1.3.6.1.4.1.534.6.7.1.1.1
                             insIdentManufacturer 1.3.6.1.4.1.534.6.7.1.1.1.1 displaystring read-only
The name of the RackMonitor manufacturer.
                             insIdentModel 1.3.6.1.4.1.534.6.7.1.1.1.2 displaystring read-only
The RackMonitor Model designation.
                             insIdentAgentSoftwareVersion 1.3.6.1.4.1.534.6.7.1.1.1.3 displaystring read-only
The RackMonitor software/firmware version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.
                             insIdentName 1.3.6.1.4.1.534.6.7.1.1.1.4 displaystring read-write
A string identifying the RackMonitor. This object should be set by the administrator.
                         rmConfig 1.3.6.1.4.1.534.6.7.1.1.2
                             rmConfigMibVersion 1.3.6.1.4.1.534.6.7.1.1.2.1 integer read-only
The version of MIB spec.
                             rmConfigNetwork 1.3.6.1.4.1.534.6.7.1.1.2.2
                                 rmConfigIpAddress 1.3.6.1.4.1.534.6.7.1.1.2.2.1 ipaddress read-write
The ip address that NMS can identify the managed device
                                 rmConfigGateway 1.3.6.1.4.1.534.6.7.1.1.2.2.2 ipaddress read-write
The default gateway that allow device managed through routers
                                 rmConfigSubnetMask 1.3.6.1.4.1.534.6.7.1.1.2.2.3 ipaddress read-write
Internet address subnet mask
                             rmConfigDateTime 1.3.6.1.4.1.534.6.7.1.1.2.3
                                 rmConfigDate 1.3.6.1.4.1.534.6.7.1.1.2.3.1 displaystring read-write
The date in Environmental Rack Monitor, format is (dd/mm/yyyy)
                                 rmConfigTime 1.3.6.1.4.1.534.6.7.1.1.2.3.2 displaystring read-write
The time in Environmental Rack Monitor, format is (hh:mm:ss)
                                 rmConfigTimeFromNtp 1.3.6.1.4.1.534.6.7.1.1.2.3.3 integer read-write
Enable/disable update of the date and time from the NTP server. Enumeration: 'disabled': 2, 'enabled': 1.
                                 rmConfigNtpIpAddress 1.3.6.1.4.1.534.6.7.1.1.2.3.4 ipaddress read-write
NTP IP address.
                                 rmConfigNtpTimeZone 1.3.6.1.4.1.534.6.7.1.1.2.3.5 integer read-write
Enable/disable update of the date and time from the NTP server. Enumeration: 'gMT-0400': 9, 'gMT-0500': 8, 'gMT1000': 26, 'gMT-0200': 12, 'gMT-0300': 11, 'gMT0330': 18, 'gMT-0000': 14, 'gMT1200': 28, 'gMT0500': 20, 'gMT-0100': 13, 'gMT1100': 27, 'gMT0600': 22, 'gMT-0800': 5, 'gMT0400': 19, 'gMT-0900': 4, 'gMT-1000': 3, 'gMT0300': 17, 'gMT-1200': 1, 'gMT-0600': 7, 'gMT-0700': 6, 'gMT0100': 15, 'gMT-0330': 10, 'gMT0200': 16, 'gMT0800': 24, 'gMT0700': 23, 'gMT0900': 25, 'gMT-1100': 2, 'gMT0530': 21.
                                 rmConfigDayLightSaving 1.3.6.1.4.1.534.6.7.1.1.2.3.6 integer read-write
Enable/disable daylight saving for NTP time, if enabled, the time obtained from the NTP will be set one hour in advance to reflect daylight saving status. Enumeration: 'disabled': 2, 'enabled': 1.
                             rmConfigLog 1.3.6.1.4.1.534.6.7.1.1.2.4
                                 rmConfigHistoryLogFrequency 1.3.6.1.4.1.534.6.7.1.1.2.4.1 integer read-write
The frequency of the history log update. The value is in seconds
                                 rmConfigExtHistoryLogFrequency 1.3.6.1.4.1.534.6.7.1.1.2.4.2 integer read-write
The frequency of the extended history log update. The value is in seconds
                                 rmConfigConfigurationLog 1.3.6.1.4.1.534.6.7.1.1.2.4.3 integer read-write
Enable/Disable Environmental Rack Monitor parameters change logging. Enumeration: 'disabled': 2, 'enabled': 1.
                             rmConfigDhcpStatue 1.3.6.1.4.1.534.6.7.1.1.2.5 integer read-write
Enable or Disable DHCP/BootP capability Enumeration: 'disabled': 2, 'enabled': 1.
                             rmConfigPingStatue 1.3.6.1.4.1.534.6.7.1.1.2.6 integer read-write
Enable or Disable Ping Echo capability Enumeration: 'disabled': 2, 'enabled': 1.
                             rmConfigTftpStatue 1.3.6.1.4.1.534.6.7.1.1.2.7 integer read-write
Enable or Disable TFTP network upgrade capability Enumeration: 'disabled': 2, 'enabled': 1.
                             rmConfigTelnet 1.3.6.1.4.1.534.6.7.1.1.2.8
                                 rmConfigTelnetStatue 1.3.6.1.4.1.534.6.7.1.1.2.8.1 integer read-write
Enable or Disable telnet access Enumeration: 'disabled': 2, 'enabled': 1.
                                 rmConfigTelnetPortNumber 1.3.6.1.4.1.534.6.7.1.1.2.8.2 integer read-write
Setting the server port for telnet.
                             rmConfigHttp 1.3.6.1.4.1.534.6.7.1.1.2.9
                                 rmConfigHttpStatue 1.3.6.1.4.1.534.6.7.1.1.2.9.1 integer read-write
Enable or Disable HTTP access Enumeration: 'disabled': 2, 'enabled': 1.
                                 rmConfigHttpPortNumber 1.3.6.1.4.1.534.6.7.1.1.2.9.2 integer read-write
Setting the server port of HTTP.
                                 rmConfigHttpSecurity 1.3.6.1.4.1.534.6.7.1.1.2.9.3 integer read-write
Enable/Disable HTTP access for read-only users Enumeration: 'disabled': 2, 'enabled': 1.
                             rmConfigSnmp 1.3.6.1.4.1.534.6.7.1.1.2.10
                                   rmConfigSnmpStatue 1.3.6.1.4.1.534.6.7.1.1.2.10.1 integer read-write
Enable or Disable SNMP access Enumeration: 'disabled': 2, 'enabled': 1.
                                   rmConfigSnmpPortNumber 1.3.6.1.4.1.534.6.7.1.1.2.10.2 integer read-write
Setting the server port for SNMP.
                             rmConfigControl 1.3.6.1.4.1.534.6.7.1.1.2.11
                                   rmConfigResetToDefault 1.3.6.1.4.1.534.6.7.1.1.2.11.1 integer read-write
Reset all parameters of Environmental Rack Monitor to default values Enumeration: 'reset': 1, 'nothing': 2.
                                   rmConfigRestart 1.3.6.1.4.1.534.6.7.1.1.2.11.2 integer read-write
Restart rm Enumeration: 'nothing': 2, 'restart': 1.
                             rmConfigTrap 1.3.6.1.4.1.534.6.7.1.1.2.12
                                   rmConfigTrapRetryCount 1.3.6.1.4.1.534.6.7.1.1.2.12.1 integer read-write
The count of repeat traps to send to NMS before trap acknowledge received.
                                   rmConfigTrapRetryTime 1.3.6.1.4.1.534.6.7.1.1.2.12.2 integer read-write
The time between retry traps sent to NMS.
                                   rmConfigTrapAckSignature 1.3.6.1.4.1.534.6.7.1.1.2.12.3 integer read-write
The signature of trap acknowledge.
                             rmConfigPollRate 1.3.6.1.4.1.534.6.7.1.1.2.13 integer read-write
The frequency that the Rack Monitor will read from sensors (unit : second).
                             rmConfigTrapsReceiversTable 1.3.6.1.4.1.534.6.7.1.1.2.14 no-access
A list of managers to send traps to. The number of entries is given by the value of rmConfigNumTrapReceivers
                                   rmConfigTrapsReceiversEntry 1.3.6.1.4.1.534.6.7.1.1.2.14.1 no-access
The managers to send traps to.
                                       trapsIndex 1.3.6.1.4.1.534.6.7.1.1.2.14.1.1 integer read-only
The index to a trap receiver entry.
                                       trapsReceiverAddr 1.3.6.1.4.1.534.6.7.1.1.2.14.1.2 ipaddress read-write
The IP address of the manager to send a trap to.
                                       receiverCommunityString 1.3.6.1.4.1.534.6.7.1.1.2.14.1.3 displaystring read-write
The community name to use in the trap when sent to the manager.
                                       receiverSeverityLevel 1.3.6.1.4.1.534.6.7.1.1.2.14.1.4 integer read-write
The severity level of traps to be received by this manager. Enumeration: 'severe': 3, 'warning': 2, 'informational': 1.
                                       receiverDescription 1.3.6.1.4.1.534.6.7.1.1.2.14.1.5 displaystring read-write
Description of trap receivers
                             rmConfigAccessControlTable 1.3.6.1.4.1.534.6.7.1.1.2.15 no-access
A list of managers which can access rm with private community string.
                                   rmConfigAccessControlEntry 1.3.6.1.4.1.534.6.7.1.1.2.15.1 no-access
The managers.
                                       accessIndex 1.3.6.1.4.1.534.6.7.1.1.2.15.1.1 integer read-only
The index to a access control entry.
                                       accessControlAddr 1.3.6.1.4.1.534.6.7.1.1.2.15.1.2 ipaddress read-write
The IP address of the manager to access RackMonitor
                                       accessCommunityString 1.3.6.1.4.1.534.6.7.1.1.2.15.1.3 displaystring read-write
The community name to use in the manager when access RackMonitor
                                       accessControlMode 1.3.6.1.4.1.534.6.7.1.1.2.15.1.4 integer read-write
Access type, only read/Write access type can change parameter of RackMonitor Enumeration: 'read-write': 2, 'readOnly': 1, 'notAccess': 3.
                             rmConfigTemperatureUnit 1.3.6.1.4.1.534.6.7.1.1.2.16 integer read-write
The temperature unit of the system, can be Celsius or Fahrenheit Enumeration: 'fahrenheit': 2, 'celsius': 1.
                             rmConfigDateFormat 1.3.6.1.4.1.534.6.7.1.1.2.17 integer read-write
The date format of the system, can be dd/mm/yyyy or mm/dd/yyyy Enumeration: 'mm-dd-yyyy': 1, 'yyyy-mm-dd': 3, 'dd-mm-yyyy': 2, 'dd-mmm-yyyy': 4.
                         sensorMonitor 1.3.6.1.4.1.534.6.7.1.1.3
                             smSensorNumber 1.3.6.1.4.1.534.6.7.1.1.3.1 integer read-only
The number of sensors that can be monitored.
                             smSensorTable 1.3.6.1.4.1.534.6.7.1.1.3.2 no-access
A list of sensor devices to be monitored.
                                 smSensorEntry 1.3.6.1.4.1.534.6.7.1.1.3.2.1 no-access
The sensor device.
                                     smDeviceIndex 1.3.6.1.4.1.534.6.7.1.1.3.2.1.1 integer read-only
The index to a sensor device entry.
                                     smDeviceStatus 1.3.6.1.4.1.534.6.7.1.1.3.2.1.2 integer read-only
The device type plugged into RackMonitor. Enumeration: 'disabled': 2, 'eMD-HT': 3, 'eMD-T': 4, 'unknow': 1.
                                     smDeviceTemperature 1.3.6.1.4.1.534.6.7.1.1.3.2.1.3 integer read-only
The temperature of sensor on device RackMonitor, the unit is 0.1 degree.
                                     smDeviceTemperatureAlarm 1.3.6.1.4.1.534.6.7.1.1.3.2.1.4 integer read-only
The status of temperature sensor on device RackMonitor. Enumeration: 'lowWarning': 4, 'highCritical': 7, 'unknow': 1, 'normal': 3, 'highWarning': 6, 'lowCritical': 5, 'disabled': 2.
                                     smDeviceHumidity 1.3.6.1.4.1.534.6.7.1.1.3.2.1.5 integer read-only
The humidity of sensor on device RackMonitor, the unit is 0.1%.
                                     smDeviceHumidityAlarm 1.3.6.1.4.1.534.6.7.1.1.3.2.1.6 integer read-only
The device type plugged into RackMonitor. Enumeration: 'lowWarning': 4, 'highCritical': 7, 'unknow': 1, 'normal': 3, 'highWarning': 6, 'lowCritical': 5, 'disabled': 2.
                                     smAlarm1 1.3.6.1.4.1.534.6.7.1.1.3.2.1.7 integer read-only
The device type plugged into RackMonitor. Enumeration: 'disabled': 2, 'active': 3, 'inactive': 4, 'unknow': 1.
                                     smAlarm2 1.3.6.1.4.1.534.6.7.1.1.3.2.1.8 integer read-only
The device type plugged into RackMonitor. Enumeration: 'disabled': 2, 'active': 3, 'inactive': 4, 'unknow': 1.
                         sensorConfig 1.3.6.1.4.1.534.6.7.1.1.4
                             scSensorNumber 1.3.6.1.4.1.534.6.7.1.1.4.1 integer read-only
The number of sensors that can be plugged into RackMonitor.
                             scSensorTable 1.3.6.1.4.1.534.6.7.1.1.4.2 no-access
A list of sensor devices to be configured.
                                 scSensorEntry 1.3.6.1.4.1.534.6.7.1.1.4.2.1 no-access
The sensor device.
                                     scDeviceIndex 1.3.6.1.4.1.534.6.7.1.1.4.2.1.1 integer read-only
The index to a sensor device entry.
                                     scDeviceName 1.3.6.1.4.1.534.6.7.1.1.4.2.1.2 displaystring read-write
The name of the sensor device for identification.
                                     scDeviceState 1.3.6.1.4.1.534.6.7.1.1.4.2.1.3 integer read-write
The setup of sensor device type. Enumeration: 'disabled': 1, 'auto': 2.
                             scSensor1 1.3.6.1.4.1.534.6.7.1.1.4.3
                                 scSensor1DeviceName 1.3.6.1.4.1.534.6.7.1.1.4.3.1 displaystring read-write
The name of sensor device.
                                 scSensor1DeviceState 1.3.6.1.4.1.534.6.7.1.1.4.3.2 integer read-write
The setup of sensor device type. Enumeration: 'disabled': 1, 'auto': 2.
                                 scSensor1Temperature 1.3.6.1.4.1.534.6.7.1.1.4.3.3
                                     scSensor1TemperatureName 1.3.6.1.4.1.534.6.7.1.1.4.3.3.1 displaystring read-write
The temperature sensor name.
                                     scSensor1TemperatureLowWarning 1.3.6.1.4.1.534.6.7.1.1.4.3.3.2 integer read-write
The set point to trigger low warning alarm.
                                     scSensor1TemperatureLowCritical 1.3.6.1.4.1.534.6.7.1.1.4.3.3.3 integer read-write
The threshold to trigger low critical alarm.
                                     scSensor1TemperatureHighWarning 1.3.6.1.4.1.534.6.7.1.1.4.3.3.4 integer read-write
The threshold to trigger high warning alarm.
                                     scSensor1TemperatureHighCritical 1.3.6.1.4.1.534.6.7.1.1.4.3.3.5 integer read-write
The threshold to trigger high critical alarm.
                                     scSensor1TemperatureHysteresis 1.3.6.1.4.1.534.6.7.1.1.4.3.3.6 integer read-write
The set value to prevent too many alarms when temperature is hovering around the set threshold.
                                     scSensor1TemperatureCalibration 1.3.6.1.4.1.534.6.7.1.1.4.3.3.7 integer read-write
The set value to get the correct temperature according to the reference temperature. Enumeration: 'temperatureMinus2Point5': 12, 'temperatureMinus2Point0': 11, 'temperatureMinus0Point5': 8, 'temperatureIncrease3Point0': 7, 'temperatureIncrease0Point0': 1, 'temperatureMinusPoint0': 13, 'temperatureIncrease0Point5': 2, 'temperatureIncrease2Point5': 6, 'temperatureIncrease1Point5': 4, 'temperatureMinus1Point5': 10, 'temperatureIncrease2Point0': 5, 'temperatureMinus1Point0': 9, 'temperatureIncrease1Point0': 3.
                                     scSensor1TemperatureLowWarningStatus 1.3.6.1.4.1.534.6.7.1.1.4.3.3.8 integer read-write
Enable/Disable the set point to trigger low warning alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor1TemperatureLowCriticalStatus 1.3.6.1.4.1.534.6.7.1.1.4.3.3.9 integer read-write
Enable/Disable the set point to trigger low critical alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor1TemperatureHighWarningStatus 1.3.6.1.4.1.534.6.7.1.1.4.3.3.10 integer read-write
Enable/Disable the set point to trigger high warning alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor1TemperatureHighCriticalStatus 1.3.6.1.4.1.534.6.7.1.1.4.3.3.11 integer read-write
Enable/disable the set point to trigger high critical alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                 scSensor1Humidity 1.3.6.1.4.1.534.6.7.1.1.4.3.4
                                     scSensor1HumdityName 1.3.6.1.4.1.534.6.7.1.1.4.3.4.1 displaystring read-write
The humidity sensor name.
                                     scSensor1HumidityLowWarning 1.3.6.1.4.1.534.6.7.1.1.4.3.4.2 integer read-write
The set point to trigger low warning alarm.
                                     scSensor1HumidityLowCritical 1.3.6.1.4.1.534.6.7.1.1.4.3.4.3 integer read-write
The threshold to trigger low critical alarm.
                                     scSensor1HumidityHighWarning 1.3.6.1.4.1.534.6.7.1.1.4.3.4.4 integer read-write
The threshold to trigger high warning alarm.
                                     scSensor1HumidityHighCritical 1.3.6.1.4.1.534.6.7.1.1.4.3.4.5 integer read-write
The threshold to trigger high critical alarm.
                                     scSensor1HumidityHysteresis 1.3.6.1.4.1.534.6.7.1.1.4.3.4.6 integer read-write
The set value to prevent too many alarms when Humidity is hovering around the set threshold.
                                     scSensor1HumidityCalibration 1.3.6.1.4.1.534.6.7.1.1.4.3.4.7 integer read-write
The set value to get the correct temperature according to your reference temperature. Enumeration: 'humidityMinus2Point0': 9, 'humidityIncrease4Point0': 5, 'humidityMinus4Point0': 11, 'humidityIncrease3Point0': 4, 'humidityIncrease1Point0': 2, 'humidityMinus1Point0': 8, 'humidityMinus5Point0': 12, 'humidityMinus3Point0': 10, 'humidityMinus6Point0': 13, 'humidityIncrease0Point0': 1, 'humidityIncrease5Point0': 6, 'humidityIncrease6Point0': 7, 'humidityIncrease2Point0': 3.
                                     scSensor1HumidityLowWarningStatus 1.3.6.1.4.1.534.6.7.1.1.4.3.4.8 integer read-write
Enable/Disable the set point to trigger low warning alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor1HumidityLowCriticalStatus 1.3.6.1.4.1.534.6.7.1.1.4.3.4.9 integer read-write
Enable/Disable the set point to trigger low critical alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor1HumidityHighWarningStatus 1.3.6.1.4.1.534.6.7.1.1.4.3.4.10 integer read-write
Enable/Disable the set point to trigger high warning alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor1HumidityHighCriticalStatus 1.3.6.1.4.1.534.6.7.1.1.4.3.4.11 integer read-write
Enable/Disable the set point to trigger high critical alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                 scSensor1Alarm1 1.3.6.1.4.1.534.6.7.1.1.4.3.5
                                     scSensor1Alarm1Name 1.3.6.1.4.1.534.6.7.1.1.4.3.5.1 displaystring read-write
The name of alarm-1.
                                     scSensor1Alarm1State 1.3.6.1.4.1.534.6.7.1.1.4.3.5.2 integer read-write
Setup the signal type to trigger alarm. Enumeration: 'disabled': 1, 'normalClose': 3, 'lowActive': 5, 'highActive': 4, 'normalOpen': 2.
                                     scSensor1Alarm1Hysteresis 1.3.6.1.4.1.534.6.7.1.1.4.3.5.3 integer read-write
The set value to delay the alarm triggered when event occurs.
                                 scSensor1Alarm2 1.3.6.1.4.1.534.6.7.1.1.4.3.6
                                     scSensor1Alarm2Name 1.3.6.1.4.1.534.6.7.1.1.4.3.6.1 displaystring read-write
The name of alarm-1.
                                     scSensor1Alarm2State 1.3.6.1.4.1.534.6.7.1.1.4.3.6.2 integer read-write
Setup the signal type to trigger alarm. Enumeration: 'disabled': 1, 'normalClose': 3, 'lowActive': 5, 'highActive': 4, 'normalOpen': 2.
                                     scSensor1Alarm2Hysteresis 1.3.6.1.4.1.534.6.7.1.1.4.3.6.3 integer read-write
The set value to delay the alarm triggered when event occurs.
                             scSensor2 1.3.6.1.4.1.534.6.7.1.1.4.4
                                 scSensor2DeviceName 1.3.6.1.4.1.534.6.7.1.1.4.4.1 displaystring read-write
The name of sensor device.
                                 scSensor2DeviceState 1.3.6.1.4.1.534.6.7.1.1.4.4.2 integer read-write
The setup of sensor device type. Enumeration: 'disabled': 1, 'auto': 2.
                                 scSensor2Temperature 1.3.6.1.4.1.534.6.7.1.1.4.4.3
                                     scSensor2TemperatureName 1.3.6.1.4.1.534.6.7.1.1.4.4.3.1 displaystring read-write
The temperature sensor name.
                                     scSensor2TemperatureLowWarning 1.3.6.1.4.1.534.6.7.1.1.4.4.3.2 integer read-write
The set point to trigger low warning alarm.
                                     scSensor2TemperatureLowCritical 1.3.6.1.4.1.534.6.7.1.1.4.4.3.3 integer read-write
The threshold to trigger low critical alarm.
                                     scSensor2TemperatureHighWarning 1.3.6.1.4.1.534.6.7.1.1.4.4.3.4 integer read-write
The threshold to trigger high warning alarm.
                                     scSensor2TemperatureHighCritical 1.3.6.1.4.1.534.6.7.1.1.4.4.3.5 integer read-write
The threshold to trigger high critical alarm.
                                     scSensor2TemperatureHysteresis 1.3.6.1.4.1.534.6.7.1.1.4.4.3.6 integer read-write
The set value to prevent too many alarms when temperature is hovering around the set threshold.
                                     scSensor2TemperatureCalibration 1.3.6.1.4.1.534.6.7.1.1.4.4.3.7 integer read-write
The set value to get the correct temperature according to your reference temperature. Enumeration: 'temperatureMinus2Point5': 12, 'temperatureMinus2Point0': 11, 'temperatureMinus0Point5': 8, 'temperatureIncrease3Point0': 7, 'temperatureIncrease0Point0': 1, 'temperatureMinusPoint0': 13, 'temperatureIncrease0Point5': 2, 'temperatureIncrease2Point5': 6, 'temperatureIncrease1Point5': 4, 'temperatureMinus1Point5': 10, 'temperatureIncrease2Point0': 5, 'temperatureMinus1Point0': 9, 'temperatureIncrease1Point0': 3.
                                     scSensor2TemperatureLowWarningStatus 1.3.6.1.4.1.534.6.7.1.1.4.4.3.8 integer read-write
Enable/Disable the set point to trigger low warning alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor2TemperatureLowCriticalStatus 1.3.6.1.4.1.534.6.7.1.1.4.4.3.9 integer read-write
Enable/Disable the set point to trigger low critical alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor2TemperatureHighWarningStatus 1.3.6.1.4.1.534.6.7.1.1.4.4.3.10 integer read-write
Enable/Disable the set point to trigger high warning alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor2TemperatureHighCriticalStatus 1.3.6.1.4.1.534.6.7.1.1.4.4.3.11 integer read-write
Enable/Disable the set point to trigger high critical alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                 scSensor2Humidity 1.3.6.1.4.1.534.6.7.1.1.4.4.4
                                     scSensor2HumdityName 1.3.6.1.4.1.534.6.7.1.1.4.4.4.1 displaystring read-write
The humidity sensor name.
                                     scSensor2HumidityLowWarning 1.3.6.1.4.1.534.6.7.1.1.4.4.4.2 integer read-write
The set point to trigger low warning alarm.
                                     scSensor2HumidityLowCritical 1.3.6.1.4.1.534.6.7.1.1.4.4.4.3 integer read-write
The threshold to trigger low critical alarm.
                                     scSensor2HumidityHighWarning 1.3.6.1.4.1.534.6.7.1.1.4.4.4.4 integer read-write
The threshold to trigger high warning alarm.
                                     scSensor2HumidityHighCritical 1.3.6.1.4.1.534.6.7.1.1.4.4.4.5 integer read-write
The threshold to trigger high critical alarm.
                                     scSensor2HumidityHysteresis 1.3.6.1.4.1.534.6.7.1.1.4.4.4.6 integer read-write
The set value to prevent too many alarms when Humidity is hovering around the set threshold.
                                     scSensor2HumidityCalibration 1.3.6.1.4.1.534.6.7.1.1.4.4.4.7 integer read-write
The set value to get the correct temperature according to the reference temperature. Enumeration: 'humidityMinus2Point0': 9, 'humidityIncrease4Point0': 5, 'humidityMinus4Point0': 11, 'humidityIncrease3Point0': 4, 'humidityIncrease1Point0': 2, 'humidityMinus1Point0': 8, 'humidityMinus5Point0': 12, 'humidityMinus3Point0': 10, 'humidityMinus6Point0': 13, 'humidityIncrease0Point0': 1, 'humidityIncrease5Point0': 6, 'humidityIncrease6Point0': 7, 'humidityIncrease2Point0': 3.
                                     scSensor2HumidityLowWarningStatus 1.3.6.1.4.1.534.6.7.1.1.4.4.4.8 integer read-write
Enable/Disable the set point to trigger low warning alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor2HumidityLowCriticalStatus 1.3.6.1.4.1.534.6.7.1.1.4.4.4.9 integer read-write
Enable/Disable the set point to trigger low critical alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor2HumidityHighWarningStatus 1.3.6.1.4.1.534.6.7.1.1.4.4.4.10 integer read-write
Enable/Disable the set point to trigger high warning alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                     scSensor2HumidityHighCriticalStatus 1.3.6.1.4.1.534.6.7.1.1.4.4.4.11 integer read-write
Enable/Disable the set point to trigger high critical alarm. Enumeration: 'disabled': 2, 'enabled': 1.
                                 scSensor2Alarm1 1.3.6.1.4.1.534.6.7.1.1.4.4.5
                                     scSensor2Alarm1Name 1.3.6.1.4.1.534.6.7.1.1.4.4.5.1 displaystring read-write
The name of alarm-1.
                                     scSensor2Alarm1State 1.3.6.1.4.1.534.6.7.1.1.4.4.5.2 integer read-write
Setup the signal type to trigger alarm. Enumeration: 'disabled': 1, 'normalClose': 3, 'lowActive': 5, 'highActive': 4, 'normalOpen': 2.
                                     scSensor2Alarm1Hysteresis 1.3.6.1.4.1.534.6.7.1.1.4.4.5.3 integer read-write
The set value to delay the alarm triggered when event occurs.
                                 scSensor2Alarm2 1.3.6.1.4.1.534.6.7.1.1.4.4.6
                                     scSensor2Alarm2Name 1.3.6.1.4.1.534.6.7.1.1.4.4.6.1 displaystring read-write
The name of alarm-1.
                                     scSensor2Alarm2State 1.3.6.1.4.1.534.6.7.1.1.4.4.6.2 integer read-write
Setup the signal type to trigger alarm. Enumeration: 'disabled': 1, 'normalClose': 3, 'lowActive': 5, 'highActive': 4, 'normalOpen': 2.
                                     scSensor2Alarm2Hysteresis 1.3.6.1.4.1.534.6.7.1.1.4.4.6.3 integer read-write
The set value to delay the alarm triggered when event occurs.
                     rmTraps 1.3.6.1.4.1.534.6.7.1.2
                           rmCommunicationRestored 1.3.6.1.4.1.534.6.7.1.20.1
INFORMATION: Communication between RackMonitor and sensor had established.
                           rmCommunicationLost 1.3.6.1.4.1.534.6.7.1.20.2
WARNING: Communication between RackMonitor and sensor had lost.
                           rmAlarm1Inactive 1.3.6.1.4.1.534.6.7.1.20.3
INFORMATION: Alarm1 of sensor had return from active state.
                           rmAlarm1Active 1.3.6.1.4.1.534.6.7.1.20.4
WARNING: Alarm1 has become active.
                           rmAlarm2Inactive 1.3.6.1.4.1.534.6.7.1.20.5
INFORMATION: Alarm2 of sensor has returned to normal state.
                           rmAlarm2Active 1.3.6.1.4.1.534.6.7.1.20.6
WARNING: Alarm2 had became active.
                           rmTemperatureNotHighWarning 1.3.6.1.4.1.534.6.7.1.20.7
INFORMATION: The temperature of sensor had return from High warning to normal.
                           rmTemperatureHighWarning 1.3.6.1.4.1.534.6.7.1.20.8
WARNING: The temperature of sensor was higher than High warning set point.
                           rmTemperatureNotLowWarning 1.3.6.1.4.1.534.6.7.1.20.9
INFORMATION: The temperature of sensor had return from low warning to normal.
                           rmTemperatureLowWarning 1.3.6.1.4.1.534.6.7.1.20.10
WARNING: The temperature of sensor was lower than low warning set point.
                           rmTemperatureNotHighCritical 1.3.6.1.4.1.534.6.7.1.20.11
INFORMATION: The temperature of sensor lower than high critical set point.
                           rmTemperatureHighCritical 1.3.6.1.4.1.534.6.7.1.20.12
CRITICAL: The temperature of sensor was higher than high critical set point.
                           rmTemperatureNotLowCritical 1.3.6.1.4.1.534.6.7.1.20.13
INFORMATION: The temperature of sensor was higher than low critical set point.
                           rmTemperatureLowCritical 1.3.6.1.4.1.534.6.7.1.20.14
CRITICAL: The temperature of sensor was lower than low critical set point.
                           rmHumidityNotHighWarning 1.3.6.1.4.1.534.6.7.1.20.15
INFORMATION: The humidity of sensor had return from High warning to normal.
                           rmHumidityHighWarning 1.3.6.1.4.1.534.6.7.1.20.16
WARNING: The humidity of sensor was higher than High warning set point.
                           rmHumidityNotLowWarning 1.3.6.1.4.1.534.6.7.1.20.17
INFORMATION: The humidity of sensor had return from low warning to normal.
                           rmHumidityLowWarning 1.3.6.1.4.1.534.6.7.1.20.18
WARNING: The humidity of sensor was lower than low warning set point.
                           rmHumidityNotHighCritical 1.3.6.1.4.1.534.6.7.1.20.19
INFORMATION: The humidity of sensor lower than high critical set point.
                           rmHumidityHighCritical 1.3.6.1.4.1.534.6.7.1.20.20
CRITICAL: The humidity of sensor was higher than high critical set point.
                           rmHumidityNotLowCritical 1.3.6.1.4.1.534.6.7.1.20.21
INFORMATION: The humidity of sensor was higher than low critical set point.
                           rmHumidityLowCritical 1.3.6.1.4.1.534.6.7.1.20.22
CRITICAL: The humidity of sensor was lower than low critical set point.