ROOMALERT7E-MIB: View SNMP OID List / Download MIB

VENDOR: AVTECH SOFTWARE


 Home MIB: ROOMALERT7E-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 avtech 1.3.6.1.4.1.20916
             products 1.3.6.1.4.1.20916.1
                 roomalert7e 1.3.6.1.4.1.20916.1.2
                     sensors 1.3.6.1.4.1.20916.1.2.1
                         temperature 1.3.6.1.4.1.20916.1.2.1.1
                             tempreading1c 1.3.6.1.4.1.20916.1.2.1.1.1 integer read-only
Temperature Sensor 1 (Celsius)
                             tempreading2c 1.3.6.1.4.1.20916.1.2.1.1.2 integer read-only
Temperature Sensor 2 (Celsius)
                             tempreading3c 1.3.6.1.4.1.20916.1.2.1.1.3 integer read-only
Temperature Sensor 3 (Celsius)
                             tempreading4c 1.3.6.1.4.1.20916.1.2.1.1.4 integer read-only
Temperature Sensor 4 (Celsius)
                             tempreading1f 1.3.6.1.4.1.20916.1.2.1.1.5 integer read-only
Temperature Sensor 1 (Fahrenheit)
                             tempreading2f 1.3.6.1.4.1.20916.1.2.1.1.6 integer read-only
Temperature Sensor 2 (Fahrenheit)
                             tempreading3f 1.3.6.1.4.1.20916.1.2.1.1.7 integer read-only
Temperature Sensor 3 (Fahrenheit)
                             tempreading4f 1.3.6.1.4.1.20916.1.2.1.1.8 integer read-only
Temperature Sensor 4 (Fahrenheit)
                         switch 1.3.6.1.4.1.20916.1.2.1.2
                             switch1 1.3.6.1.4.1.20916.1.2.1.2.1 integer read-only
Switch Sensor 1 (0 = OFF, 1 = ON)
                             switch2 1.3.6.1.4.1.20916.1.2.1.2.2 integer read-only
Switch Sensor 2 (0 = OFF, 1 = ON)
                             switch3 1.3.6.1.4.1.20916.1.2.1.2.3 integer read-only
Switch Sensor 3 (0 = OFF, 1 = ON)
                     traps 1.3.6.1.4.1.20916.1.2.2
                         alarmtemp1 1.3.6.1.4.1.20916.1.2.2.1 integer read-only
Alarm for temperature 1 0 = temperature OK 1 = temperature too high 2 = temperature too low
                         alarmtemp2 1.3.6.1.4.1.20916.1.2.2.2 integer read-only
Alarm for temperature 2 0 = temperature OK 1 = temperature too high 2 = temperature too low
                         alarmtemp3 1.3.6.1.4.1.20916.1.2.2.3 integer read-only
Alarm for temperature 3 0 = temperature OK 1 = temperature too high 2 = temperature too low
                         alarmtemp4 1.3.6.1.4.1.20916.1.2.2.4 integer read-only
Alarm for temperature 4 0 = temperature OK 1 = temperature too high 2 = temperature too low
                         alarmswitch1 1.3.6.1.4.1.20916.1.2.2.5 integer read-only
Alarm for switch sensor 1 0 = Switch Open 1 = Switch Closed
                         alarmswitch2 1.3.6.1.4.1.20916.1.2.2.6 integer read-only
Alarm for switch sensor 2 0 = Switch Open 1 = Switch Closed
                         alarmswitch3 1.3.6.1.4.1.20916.1.2.2.7 integer read-only
Alarm for switch sensor 3 0 = Switch Open 1 = Switch Closed
                         alarmmessage 1.3.6.1.4.1.20916.1.2.2.8 octet string read-write
Message string to send with trap messages
                     thresholds 1.3.6.1.4.1.20916.1.2.3
                         upperlimit1 1.3.6.1.4.1.20916.1.2.3.1 integer read-only
High temperature threshold for temperature sensor 1
                         lowerlimit1 1.3.6.1.4.1.20916.1.2.3.2 integer read-only
Low temperature threshold for temperature sensor 1
                         upperlimit2 1.3.6.1.4.1.20916.1.2.3.3 integer read-only
High temperature threshold for temperature sensor 2
                         lowerlimit2 1.3.6.1.4.1.20916.1.2.3.4 integer read-only
Low temperature threshold for temperature sensor 2
                         upperlimit3 1.3.6.1.4.1.20916.1.2.3.5 integer read-only
High temperature threshold for temperature sensor 3
                         lowerlimit3 1.3.6.1.4.1.20916.1.2.3.6 integer read-only
Low temperature threshold for temperature sensor 3
                         upperlimit4 1.3.6.1.4.1.20916.1.2.3.7 integer read-only
High temperature threshold for temperature sensor 4
                         lowerlimit4 1.3.6.1.4.1.20916.1.2.3.8 integer read-only
Low temperature threshold for temperature sensor 4
                       alarmstart1_7e 1.3.6.1.4.1.20916.1.20.1
A alarmstart1 trap signifies that the current temperature on sensor 1 is outside the defined high or low threshold.
                       room_alert_7e_snmp_trap 1.3.6.1.4.1.20916.1.20.2
A room-alert-7e-snmp-trap indicates that an alarm condition has occurred on the sensor inidcated by the alarmmessage variable.
                       alarmstart2_7e 1.3.6.1.4.1.20916.1.20.3
A alarmstart2 trap signifies that the current temperature on sensor 2 is outside the defined high or low threshold.
                       alarmclear2_7e 1.3.6.1.4.1.20916.1.20.4
A alarmclear2 trap signifies that the current temperature on sensor 2 has returned to a normal condition and is within the defined high or low threshold.
                       alarmstart3_7e 1.3.6.1.4.1.20916.1.20.5
A alarmstart3 trap signifies that the current temperature on sensor 3 is outside the defined high or low threshold.
                       alarmclear3_7e 1.3.6.1.4.1.20916.1.20.6
A alarmclear3 trap signifies that the current temperature on sensor 3 has returned to a normal condition and is within the defined high or low threshold.
                       alarmstart4_7e 1.3.6.1.4.1.20916.1.20.7
A alarmstart4 trap signifies that the current temperature on sensor 4 is outside the defined high or low threshold.
                       alarmclear4_7e 1.3.6.1.4.1.20916.1.20.8
A alarmclear4 trap signifies that the current temperature on sensor 4 has returned to a normal condition and is within the defined high or low threshold.
                       alarmstart5_7e 1.3.6.1.4.1.20916.1.20.9
A alarmstart5 trap signifies that the current status of switch sensor 1 is outside the defined threshold.
                       alarmclear5_7e 1.3.6.1.4.1.20916.1.20.10
A alarmclear5 trap signifies that the current status of switch sensor 1 is outside the defined threshold.
                       alarmstart6_7e 1.3.6.1.4.1.20916.1.20.11
A alarmstart6 trap signifies that the current status of switch sensor 2 is outside the defined threshold.
                       alarmclear6_7e 1.3.6.1.4.1.20916.1.20.12
A alarmclear6 trap signifies that the current status of switch sensor 2 is outside the defined threshold.
                       alarmstart7_7e 1.3.6.1.4.1.20916.1.20.13
A alarmstart7 trap signifies that the current status of switch sensor 3 is outside the defined threshold.
                       alarmclear7_7e 1.3.6.1.4.1.20916.1.20.14
A alarmclear7 trap signifies that the current status of switch sensor 3 is outside the defined threshold.