RETIX-METROLAN-MIB: View SNMP OID List / Download MIB

VENDOR: RETIX


 Home MIB: RETIX-METROLAN-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 metroLanDS3ATM 1.3.6.1.2.1.37
       atmBandwithGroup 1.3.6.1.2.1.37.1
           atmBWGBandwidth 1.3.6.1.2.1.37.1.1 integer read-write
The bandwidth amount (in Kbps) assigned to a specific bandwidth group. Total bandwidth for all eight groups can not exceed the maximum, which is 36880.
           atmBWGConfig 1.3.6.1.2.1.37.1.2 integer read-write
this carry out the actual SET of the bandwidth group. a SYSTEM RESET will be executed for the changes in bandwidth group to take effect. Enumeration: 'go': 1.
       atmLogicalPort 1.3.6.1.2.1.37.2
           atmRX_VCI 1.3.6.1.2.1.37.2.1 integer read-write
Receive VCI #. can be set as the same as atmTX-VCI
           atmRX_VPI 1.3.6.1.2.1.37.2.2 integer read-write
Receive VPI #. can be set as the same as atmTX-VPI
           atmTX_VCI 1.3.6.1.2.1.37.2.3 integer read-write
Transmit VCI #. choose a unique number for each ATM logical port.
           atmTX_VPI 1.3.6.1.2.1.37.2.4 integer read-write
Transmit VPI #.
           atmBWG 1.3.6.1.2.1.37.2.5 integer read-write
Bandwidth group number. That paticular bandwidthgroup must be configured with a positive bandwidth
           atmEncaps 1.3.6.1.2.1.37.2.6 integer read-write
Encapsulation Enumeration: 'llcEncaps': 7, 'vcBridged8023': 2.
           atmPortConfig 1.3.6.1.2.1.37.2.7 integer read-write
this carry out the actual SET of the logical port. 0 deletes the existing port, 1 creates a new logical port
       ds3FrameDevice 1.3.6.1.2.1.37.3
           ds3NoSignalCntr 1.3.6.1.2.1.37.3.1 integer read-only
NoSignalCntr stat
           ds3NoDS3FrameCntr 1.3.6.1.2.1.37.3.2 integer read-only
NoDS3FrameCntr stat
           ds3AISDetectCntr 1.3.6.1.2.1.37.3.3 integer read-only
AISDetectCntr stat
           ds3YellowAlarmCntr 1.3.6.1.2.1.37.3.4 integer read-only
YellowAlarmCntr stat
           ds3FErrCntr 1.3.6.1.2.1.37.3.5 integer read-only
FErrCntr stat
           ds3PErrCntr 1.3.6.1.2.1.37.3.6 integer read-only
PErrCntr stat
           ds3CPErrCntr 1.3.6.1.2.1.37.3.7 integer read-only
CPErrCntr stat
           ds3FEBlockErrCntr 1.3.6.1.2.1.37.3.8 integer read-only
FEBlockErrCntr stat
           ds3BPVErrCntr 1.3.6.1.2.1.37.3.9 integer read-only
BPVErrCntr stat
           ds3ATMOCD 1.3.6.1.2.1.37.3.10 integer read-only
ATMOCD stat
           ds3FIFOOverflow 1.3.6.1.2.1.37.3.11 integer read-only
FIFOOverflow stat
           ds3RAI 1.3.6.1.2.1.37.3.12 integer read-only
RAI stat
           ds3RAICntr 1.3.6.1.2.1.37.3.13 integer read-only
RAICntr stat
           ds3SignalLoss 1.3.6.1.2.1.37.3.14 integer read-only
SignalLoss stat
           ds3FrameLoss 1.3.6.1.2.1.37.3.15 integer read-only
FrameLoss stat
           ds3SyncLoss 1.3.6.1.2.1.37.3.16 integer read-only
SyncLoss stat
           ds3YellowAlarm 1.3.6.1.2.1.37.3.17 integer read-only
YellowAlarm stat
           ds3AISDetect 1.3.6.1.2.1.37.3.18 integer read-only
AISDetect stat
           ds3ClearErrorCntr 1.3.6.1.2.1.37.3.19 integer read-write
SET this object will clear the Error Counters. Enumeration: 'set': 1.
           ds3GFCInsertion 1.3.6.1.2.1.37.3.20 integer read-write
Insertion of GFC bits
           ds3BipolarSerialIO 1.3.6.1.2.1.37.3.21 integer read-write
Bipolar serial IO
           ds3PayloadScrambling 1.3.6.1.2.1.37.3.22 integer read-write
Payload scrambling
           ds3PLCPOverheadProc 1.3.6.1.2.1.37.3.23 integer read-write
PLCP overhead processing
           ds3FEBEGeneration 1.3.6.1.2.1.37.3.24 integer read-write
FEBE error generation
           ds3LoopBack 1.3.6.1.2.1.37.3.25 integer read-write
LoopBack Mode
           ds3FEACGenNDetect 1.3.6.1.2.1.37.3.26 integer read-write
FEAC generation/detection
           ds3RcvEQ 1.3.6.1.2.1.37.3.27 integer read-write
Use internal receive equalizer
           ds3XmitLevel 1.3.6.1.2.1.37.3.28 integer read-write
transmit level: use normal (low) or long (high) cables
 retix 1.3.6.1.4.1.72
       metroLanSS 1.3.6.1.4.1.72.20
             ssUnitProfile 1.3.6.1.4.1.72.20.1
                 ssBaseModule 1.3.6.1.4.1.72.20.1.1 integer read-only
Identifies the type of main board card type
                 ssIO1Module 1.3.6.1.4.1.72.20.1.2 integer read-only
I/O 1 card type Enumeration: 'feast-card-id': 3, 'stakBus-card-id': 4, 'atm-card-id': 5, 'vacant': 1, 'pcnet-6-card-id': 2.
                 ssIO2Module 1.3.6.1.4.1.72.20.1.3 integer read-only
I/O 2 card type Enumeration: 'feast-card-id': 3, 'stakBus-card-id': 4, 'atm-card-id': 5, 'vacant': 1, 'pcnet-6-card-id': 2.
             ssBaseUnit 1.3.6.1.4.1.72.20.2
                 ssBaseBootFWVer 1.3.6.1.4.1.72.20.2.1 integer read-only
Version number of current boot firmware
                 ssBaseSoftVer 1.3.6.1.4.1.72.20.2.2 integer read-only
Version number of current software
                 ssErrorLog 1.3.6.1.4.1.72.20.2.3 integer read-write
A stored value indicating that the unit has experienced a fault. Log information is formatted as a four digit hex number. Set to zero to clear the logged fault. Record this value and call Retix technical support.
             ssStakBus 1.3.6.1.4.1.72.20.3
                 ssStkBusIOPort 1.3.6.1.4.1.72.20.3.1 integer read-only
which I/O port is StakBus installed. (only 1 stakbus per system is allowed) Enumeration: 'not-installed': 3, 'on-IO2': 2, 'on-IO1': 1.
                 ssStkBusSpeed 1.3.6.1.4.1.72.20.3.2 integer read-only
StakBus speed. 175000000, or 0 if no StakBus card installed
                 ssStkBusNodeAddr 1.3.6.1.4.1.72.20.3.3 integer read-only
Module ID for StakBus card
                 ssStkBusRingOp 1.3.6.1.4.1.72.20.3.4 integer read-only
StakBus Ring OperationalStatus Enumeration: 'ringOperational': 1, 'notInstalled': 3, 'ringNotOperational': 2.
             ssVirtualLan 1.3.6.1.4.1.72.20.4
                 ssVLANEnDisable 1.3.6.1.4.1.72.20.4.1 integer read-write
Globally enable/disable VLAN for the system
                 portVLANTable 1.3.6.1.4.1.72.20.4.2 no-access
Table of port based VLAN configurations. Entries (rows) are added to the table by issuing a SET command with the EnableAdd value for the portVLANEntryEdit object. The new row is created using the instantiations.
                     portVLANEntry 1.3.6.1.4.1.72.20.4.2.1 no-access
a VLAN entry containing portID, VLANID, ...
                         ssVLANEntryPortID 1.3.6.1.4.1.72.20.4.2.1.1 integer read-write
Port ID
                         ssVLANEntryVLANID 1.3.6.1.4.1.72.20.4.2.1.2 integer read-write
Vlan ID
                         ssVLANEntryEdit 1.3.6.1.4.1.72.20.4.2.1.3 integer read-write
When set to enableAdd(1) the instantiations will be used to create a new table entry (row). Existing entries can be disabled(2) or deleted (3). Enumeration: 'disable': 2, 'enable-add': 1, 'delete': 3.
             ssSlip 1.3.6.1.4.1.72.20.5
                 slipEnable 1.3.6.1.4.1.72.20.5.1 integer read-write
enable/disable SLIP
                 slipHostIP 1.3.6.1.4.1.72.20.5.2 ipaddress read-write
SLIP Remote IP Addr