REDLINE-BS-MIB: View SNMP OID List / Download MIB

VENDOR: REDLINE COMMUNICATIONS INC.


 Home MIB: REDLINE-BS-MIB
Download as:   

Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 redlineBsMib 1.3.6.1.4.1.10728.2.1.2
This MIB module contains object definitions applicable only to Redline Base Station.
     redlineBsDhcpObjects 1.3.6.1.4.1.10728.2.1.2.1
         redlineBsIpAddressSource 1.3.6.1.4.1.10728.2.1.2.1.1 integer read-write
Setting this variable to 1 causes the Base Station to obatain its ip address from DHCP server. Enumeration: 'dhcp': 1, 'static': 2.
         redlineBsDhcpPacketsRelay 1.3.6.1.4.1.10728.2.1.2.1.2 integer read-write
Setting this variable to 1 causes the Base Station to act as DHCP relay agent for SS. Note: This object can not be set to 'relay' if usage of DHCP server is disabled. An attempt to set the address will fail and return 'resourceUnavailable' error Enumeration: 'notRelay': 2, 'relay': 1.
     redlineBsSntpObjects 1.3.6.1.4.1.10728.2.1.2.2
         redlineBsRefreshTime 1.3.6.1.4.1.10728.2.1.2.2.1 integer read-write
Setting this variable to 1 causes the Base Station to reconect to time server and synchronize the time Enumeration: 'noop': 1, 'refresh': 2.
         redlineBsDayLightSaving 1.3.6.1.4.1.10728.2.1.2.2.2 integer read-write
This variable indicates if Dalight saving is on. Enumeration: 'on': 1, 'off': 2.
         redlineBsTimezone 1.3.6.1.4.1.10728.2.1.2.2.3 integer read-write
This variable is a time zone set as +/- hours from Greenwich Mean Time (GMT). Note: This object can not be set if usage of DHCP server is enabled. An attempt to set the timezone will fail and return 'resourceUnavailable' error
         redlineBsTimeServerIpAddressType 1.3.6.1.4.1.10728.2.1.2.2.4 inetaddresstype read-write
The INET address type of Ip address of time server. IPv4 type supported only. Enumeration: 'ipv4': 1.
         redlineBsTimeServerIpAddress 1.3.6.1.4.1.10728.2.1.2.2.5 inetaddress read-write
The INET address of time server to whom Bs will communicate using SNTP protocol to obtain the GMT time.
         redlineBsTimezoneMin 1.3.6.1.4.1.10728.2.1.2.2.6 integer read-write
This variable contains a minutes part of time zone defined in 'redlineBsTimezone'. Note: This object can not be set if usage of DHCP server is enabled. An attempt to set the timezone will fail and return 'resourceUnavailable' error
     redlineBsConfigSaveObjects 1.3.6.1.4.1.10728.2.1.2.3
         redlineBsSnmpConfigSave 1.3.6.1.4.1.10728.2.1.2.3.1 integer read-write
Setting this variable to 1 causes SNMP Configuration to be save in flash. Enumeration: 'save': 2, 'noop': 1.
         redlineBsSfConfigSave 1.3.6.1.4.1.10728.2.1.2.3.2 integer read-write
Setting this variable to 2 causes Service Flow Configuration to be saved in flash. Enumeration: 'save': 2, 'noop': 1.
     redlineBsSystemObjects 1.3.6.1.4.1.10728.2.1.2.4
         redlineBsRadioType 1.3.6.1.4.1.10728.2.1.2.4.1 octet string read-only
This object indicates the radio type of Redline Bs.
     redlineBsRfObjects 1.3.6.1.4.1.10728.2.1.2.5
         redlineBsDownlinkChanFreq 1.3.6.1.4.1.10728.2.1.2.5.1 unsigned32 read-only
Current downlink channel frequency (kHz)
         redlineBsUplinkChanFreq 1.3.6.1.4.1.10728.2.1.2.5.2 unsigned32 read-only
Current uplink channel frequency (kHz)
     redlineBsPhyObjects 1.3.6.1.4.1.10728.2.1.2.6
         redlineBsChannelSize 1.3.6.1.4.1.10728.2.1.2.6.1 unsigned32 read-only
Current channel size (Khz).
     redlineBsEthObjects 1.3.6.1.4.1.10728.2.1.2.7
         redlineBsManagementAccess 1.3.6.1.4.1.10728.2.1.2.7.1 integer read-only
Indicates current management access configuration( either data or mgt port. Enumeration: 'dataPort': 1, 'mgtPort': 2.
         redlineBsDataPortSettings 1.3.6.1.4.1.10728.2.1.2.7.2 integer read-only
Indicates current settings of data port. Enumeration: 'autoDetect': 1, 'halfDuplex100': 4, 'fullDuplex10': 3, 'halfDuplex10': 5, 'fullDuplex100': 2.
         redlineBsMgtPortSettings 1.3.6.1.4.1.10728.2.1.2.7.3 integer read-only
Indicates current settings of mgt port. Enumeration: 'autoDetect': 1, 'halfDuplex100': 4, 'fullDuplex10': 3, 'halfDuplex10': 5, 'fullDuplex100': 2.
     redlineBsVlanObjects 1.3.6.1.4.1.10728.2.1.2.8
         redlineBsVlanTrafficTagging 1.3.6.1.4.1.10728.2.1.2.8.1 integer read-only
Indicates that management with VLAN tagged traffic is enabled. Enumeration: 'disabled': 2, 'enabled': 1.
         redlineBsVlanId 1.3.6.1.4.1.10728.2.1.2.8.2 unsigned32 read-only
VLAN identifier used to tag managment traffic.
     redlineBsSmcObjects 1.3.6.1.4.1.10728.2.1.2.9
         redlineBsSmcCurrentOperMode 1.3.6.1.4.1.10728.2.1.2.9.1 integer read-write
Indicates BS SMC (Secondary Management Channel) operation window. At the beginning of a maintenance window (upgrade, config backup etc), the SMC will be assigned maximum bandwidth to the predetermined fixed rate. At the end of the maintenance window, the maximum bandwidth for the SMC will be reset to its normal rate. Enumeration: 'maintenance': 2, 'normal': 1.
     redlineBsPowerSupplyAndCoolingObjects 1.3.6.1.4.1.10728.2.1.2.10
           redlineBsPowerSupplyTable 1.3.6.1.4.1.10728.2.1.2.10.1 no-access
This table contains identification and status information about base station power supplies. A trap will be generated each time the power supply goes on or off. The traps generation can be enabled/disabled using Redline Trap Activation Table.
               redlineBsPowerSupplyEntry 1.3.6.1.4.1.10728.2.1.2.10.1.1 no-access
This entry contains status information about base station power supply.
                   redlineBsPowerSupplyIndex 1.3.6.1.4.1.10728.2.1.2.10.1.1.1 integer32 no-access
The index of the BS power supply table.
                   redlineBsPowerSupplyName 1.3.6.1.4.1.10728.2.1.2.10.1.1.2 displaystring read-only
Textual identification of base station power supply.
                   redlineBsPowerSupplyType 1.3.6.1.4.1.10728.2.1.2.10.1.1.3 integer read-only
The power supply type. Enumeration: 'internal': 1, 'externalShared': 3, 'external': 2.
                   redlineBsPowerSupplyStatus 1.3.6.1.4.1.10728.2.1.2.10.1.1.4 integer read-only
Indicates if the power supply is on/off. Enumeration: 'on': 1, 'off': 2.
           redlineBsTemperatureTable 1.3.6.1.4.1.10728.2.1.2.10.2 no-access
This table contains information about current temperature of base station hardware units.
               redlineBsTemperatureEntry 1.3.6.1.4.1.10728.2.1.2.10.2.1 no-access
This entry contains temperature information about single base station hardware unit.
                   redlineBsUnitIndex 1.3.6.1.4.1.10728.2.1.2.10.2.1.1 integer32 no-access
The index of the BS current temperature table.
                   redlineBsUnitName 1.3.6.1.4.1.10728.2.1.2.10.2.1.2 displaystring read-only
The base station hardware unit name.
                   redlineBsUnitType 1.3.6.1.4.1.10728.2.1.2.10.2.1.3 integer read-only
The base station hardware unit type. Enumeration: 'outdoor': 2, 'indoor': 1.
                   redlineBsCurrTemperature 1.3.6.1.4.1.10728.2.1.2.10.2.1.4 integer32 read-only
Indicates the current temperature of base station hardware unit in Celsius.
           redlineBsTempThresholdTable 1.3.6.1.4.1.10728.2.1.2.10.3 no-access
This table contains various temperature threshold which are used to trigger traps to alarm network manager about unit mulfunction. The table is indexed by 'redlineBsUnitIndex' and 'redlineBsTempThresholdIndex' objects. Some of the traps require clearing after the temperature is going back to normal. The traps can be enabled/disabled using Redline Trap Activation table.
               redlineBsTempThresholdEntry 1.3.6.1.4.1.10728.2.1.2.10.3.1 no-access
This entry contains single base station hardware unit temperarure threshold information.
                   redlineBsTempThresholdIndex 1.3.6.1.4.1.10728.2.1.2.10.3.1.1 integer32 no-access
The index of the temperature threshold table.
                   redlineBsTempTrapThreshold 1.3.6.1.4.1.10728.2.1.2.10.3.1.2 integer32 read-only
Indicates the temperature threshold value which will be used to trigger a trap.
                   redlineBsTempTrapClrThreshold 1.3.6.1.4.1.10728.2.1.2.10.3.1.3 integer32 read-only
Indicates the temperature threshold value which will be used to clear a previosly generated trap.
                   redlineBsTempThresholdName 1.3.6.1.4.1.10728.2.1.2.10.3.1.4 displaystring read-only
Textual identification of temperature threshold.
                   redlineBsTemperatureTrapTrigger 1.3.6.1.4.1.10728.2.1.2.10.3.1.5 integer read-only
Indicates if temperature traversal in upper or lower value direction is causing the trap. Enumeration: 'temperatureRising': 1, 'temperatureFalling': 2.
           redlineBsFanTable 1.3.6.1.4.1.10728.2.1.2.10.4 no-access
This table contains name and status information about base station cooling fans. Up to 3 entries are supported.
               redlineBsFanEntry 1.3.6.1.4.1.10728.2.1.2.10.4.1 no-access
This entry contains information about single cooling fan.
                   redlineBsFanIndex 1.3.6.1.4.1.10728.2.1.2.10.4.1.1 integer32 no-access
The index of the colling fans table.
                   redlineBsFanName 1.3.6.1.4.1.10728.2.1.2.10.4.1.2 displaystring read-only
Textual identification of base station fan.
                   redlineBsFanStatus 1.3.6.1.4.1.10728.2.1.2.10.4.1.3 integer read-only
Indicates the base station fan is on/off. Enumeration: 'on': 1, 'off': 2.
     redlineBsNotificationObjects 1.3.6.1.4.1.10728.2.1.2.11
           redlineBsTrapDefinitions 1.3.6.1.4.1.10728.2.1.2.11.0
               redlineBsPowerSupplyStatusTrap 1.3.6.1.4.1.10728.2.1.2.11.0.1
Event that reports base station power supply status change (on/off).
               redlineBsTempThresholdTrap 1.3.6.1.4.1.10728.2.1.2.11.0.2
Event that reports SW Upgrade progress and status changes.
           redlineBsTrapMibObjects 1.3.6.1.4.1.10728.2.1.2.11.1
               redlineBsTrapType 1.3.6.1.4.1.10728.2.1.2.11.1.1 integer no-access
Indicates if the trap is for alarm condition or for its clearing. Enumeration: 'trapClr': 2, 'trapSet': 1.
               redlineBsTrapPowerSupplyIndex 1.3.6.1.4.1.10728.2.1.2.11.1.2 integer32 no-access
The index in the table representing BS power supply triggering the trap.
               redlineBsTrapUnitIndex 1.3.6.1.4.1.10728.2.1.2.11.1.3 integer32 no-access
The index of temperature table representing BS unit triggering the trap.
               redlineBsTrapTempThresholdIndex 1.3.6.1.4.1.10728.2.1.2.11.1.4 integer32 no-access
The index of the temperature threshold table representing the temperature threshold which passing is triggering the trap.
     redlineBsConformance 1.3.6.1.4.1.10728.2.1.2.12
           redlineBsGroups 1.3.6.1.4.1.10728.2.1.2.12.1
               redlineBsDhcpGroup 1.3.6.1.4.1.10728.2.1.2.12.1.1
Dhcp objects.
               redlineBsSntpGroup 1.3.6.1.4.1.10728.2.1.2.12.1.2
Sntp objects.
               redlineBsConfigSaveGroup 1.3.6.1.4.1.10728.2.1.2.12.1.3
Config save objects.
               redlineBsSystemGroup 1.3.6.1.4.1.10728.2.1.2.12.1.4
Config save objects.
               redlineBsRfGroup 1.3.6.1.4.1.10728.2.1.2.12.1.5
Config save objects.
               redlineBsPhyGroup 1.3.6.1.4.1.10728.2.1.2.12.1.6
Config save objects.
               redlineBsEthGroup 1.3.6.1.4.1.10728.2.1.2.12.1.7
Ethernet interface objects.
               redlineBsVlanGroup 1.3.6.1.4.1.10728.2.1.2.12.1.8
Vlan objects.
               redlineBsSmcGroup 1.3.6.1.4.1.10728.2.1.2.12.1.9
Smc objects.
               redlineBsPowerSupplyAndCoolingGroup 1.3.6.1.4.1.10728.2.1.2.12.1.10
Power supply, temperature and fans objects.
               redlineBsNotificationGroup 1.3.6.1.4.1.10728.2.1.2.12.1.11
           redlineBsCompls 1.3.6.1.4.1.10728.2.1.2.12.2
               redlineBsCompliance 1.3.6.1.4.1.10728.2.1.2.12.2.1
The compliance statement for SNMP entities that implement this MIB module.