Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 redlineAn80iMib 1.3.6.1.4.1.10728.2.1.3
This MIB module contains object definitions applicable only to Redline AN80i switched device.
     redlineAn80iTrapDefinitions 1.3.6.1.4.1.10728.2.1.3.0
         an80iPswdChangeFailTrap 1.3.6.1.4.1.10728.2.1.3.0.1
An event to report the failure of a password change.
         an80iFirmwareConfigFailTrap 1.3.6.1.4.1.10728.2.1.3.0.2
An event to report the failure of a firmware config.
         an80iEepromCorruptedTrap 1.3.6.1.4.1.10728.2.1.3.0.3
An event to report the corruption of the EEPROM.
         an80iHardwareFailTrap 1.3.6.1.4.1.10728.2.1.3.0.4
An event to report the hardware failure.
         an80iSaveConfigTrap 1.3.6.1.4.1.10728.2.1.3.0.5
An event to report the saving of configuration
         an80iDFSEventTrap 1.3.6.1.4.1.10728.2.1.3.0.6
An event to report the radar frequency detection
         an80iIdChangedTrap 1.3.6.1.4.1.10728.2.1.3.0.7
Event that reports the modification in the configuration of an ID.
         an80iSWUpgradeFailed 1.3.6.1.4.1.10728.2.1.3.0.8
Event that reports the failure of a software upgrade opration.
         an80iSWUpgradeSuccess 1.3.6.1.4.1.10728.2.1.3.0.9
Event that reports the success of a software upgrade opration.
     redlineAn80iPtpPmpObjects 1.3.6.1.4.1.10728.2.1.3.1
         redlineAn80iSystemObjects 1.3.6.1.4.1.10728.2.1.3.1.1
             an80iOptionsKeyTable 1.3.6.1.4.1.10728.2.1.3.1.1.1 no-access
This table contains options key information. The maximum number of configured options key is 2.
                 an80iOptionsKeyEntry 1.3.6.1.4.1.10728.2.1.3.1.1.1.1 no-access
This table provides one row for each option key defined in the AN80i system
                     an80iOptionsKeyId 1.3.6.1.4.1.10728.2.1.3.1.1.1.1.1 integer no-access
The Options Key Identifier.
                     an80iOptionsKey 1.3.6.1.4.1.10728.2.1.3.1.1.1.1.2 displaystring read-only
The options key value.
                     an80iOptionsKeyStatus 1.3.6.1.4.1.10728.2.1.3.1.1.1.1.3 rowstatus read-only
This object is used to ctivate and deactivate rows in the an80iOptionsKeyTable table. There will be only two rows in the table and only one will be active. When one row is active the other one will be notInService. The row can not be created or deleted
             an80iHardwareType 1.3.6.1.4.1.10728.2.1.3.1.1.2 integer32 read-only
The type/version/revision of the hardware.
             an80iRadioType 1.3.6.1.4.1.10728.2.1.3.1.1.3 integer32 read-only
The radio type.
             an80iSaveConfig 1.3.6.1.4.1.10728.2.1.3.1.1.4 integer read-write
This object will save the configuration in the nonvolatile memory and will activate the new configuration. Enumeration: 'noop': 1, 'saveConfig': 2.
             an80iActivateConfig 1.3.6.1.4.1.10728.2.1.3.1.1.5 integer read-write
This object will activate the new configuration without saving it in the nonvolatile memory. If after this event it will elapse more than 5 minutes and no save configuration occurs, then system will restart with the configuration from the nonvolatile memory. Enumeration: 'activeConfig': 2, 'noop': 1.
         redlineAn80iWirelesObjects 1.3.6.1.4.1.10728.2.1.3.1.2
             an80iAntennaAllignmentMode 1.3.6.1.4.1.10728.2.1.3.1.2.1 integer read-write
Specifies if the antenna alignment buzzer is enabled or not. In the future, new alignment methods may be added. Enumeration: 'buzzer': 2, 'off': 1.
             an80iCurrTxPower 1.3.6.1.4.1.10728.2.1.3.1.2.2 integer read-only
The actual Tx Power of the AN-80i Node.
             an80iChannelAutoScan 1.3.6.1.4.1.10728.2.1.3.1.2.3 integer read-write
Specifies if the frequency auto-scanning feature is enabled Enumeration: 'enable': 1, 'disable': 2.
             an80iCurrFrequency 1.3.6.1.4.1.10728.2.1.3.1.2.4 integer32 read-only
The central frequency on which the equipment operates. If the auto-scanning feature is enabled then this may be different than the an80iOPeratingFrequency. [KHz]
             an80iOPeratingFrequency 1.3.6.1.4.1.10728.2.1.3.1.2.5 integer32 read-write
Specifies the operating frequency of the system [KHz].
             an80iMaxTxPower 1.3.6.1.4.1.10728.2.1.3.1.2.6 integer read-write
The Tx Power of the AN-80i. Specifies the power level of the system, which is preset at the factory and should not be altered. In the event that this parameter needs to be changed, please contact the Redline support team.
             an80iSystemMode 1.3.6.1.4.1.10728.2.1.3.1.2.7 integer read-write
1 = PMP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master Enumeration: 'pmpSlave': 3, 'pmpMaster': 4, 'ptpSlave': 1, 'ptpMaster': 2.
             an80iRFStatusCode 1.3.6.1.4.1.10728.2.1.3.1.2.8 integer32 read-only
Specifies the Error Code for the RF Interface.
             an80iDFSAction 1.3.6.1.4.1.10728.2.1.3.1.2.9 integer read-write
Action taken when a radar is detected on the same frequency. Enumeration: 'none': 1, 'changeFreq': 3, 'txDisabled': 2.
             an80iAntennaGain 1.3.6.1.4.1.10728.2.1.3.1.2.10 integer32 read-write
The gain of the antenna attached to the system.
             an80iActiveRFLinks 1.3.6.1.4.1.10728.2.1.3.1.2.11 integer32 read-only
The actual number of provisioned links.
             an80iAtpControl 1.3.6.1.4.1.10728.2.1.3.1.2.12 integer read-write
Enable/disable the automatic Tx power control. Enumeration: 'enable': 1, 'disable': 2.
             an80iTurboModeControl 1.3.6.1.4.1.10728.2.1.3.1.2.13 integer read-write
Enable/disable the turbo mode. In this mode the system uses a 40MHz channel (20 MHz in normal mode). Enumeration: 'enable': 1, 'disable': 2.
             an80iChannelWidth 1.3.6.1.4.1.10728.2.1.3.1.2.14 integer read-write
The width of the channel. Enumeration: 'chWidth40MHz': 7, 'chWidth20MHz': 6, 'chWidth10MHz': 5.
         redlineAn80iEthernetObjects 1.3.6.1.4.1.10728.2.1.3.1.3
             an80iEtherPortConn 1.3.6.1.4.1.10728.2.1.3.1.3.1 integer read-write
Specifies Ethernet port connection auto(1), mdi(2) or mdix(3) Enumeration: 'auto': 1, 'crossover': 3, 'normal': 2.
             an80iEtherPortMode 1.3.6.1.4.1.10728.2.1.3.1.3.2 integer read-write
The attribute specifies the Ethernet LED status of the AN80i. Enumeration: 'auto': 1, 'e10hd': 2, 'e100hd': 4, 'e100fd': 5, 'e10fd': 3.
             an80iFlowControl 1.3.6.1.4.1.10728.2.1.3.1.3.3 integer read-write
This object specifies if flow control is enabled or not. Enumeration: 'disabled': 2, 'enabled': 1.
             an80iLowLatencyMode 1.3.6.1.4.1.10728.2.1.3.1.3.4 integer read-write
This object specifies if prioritized low latency mode is enabled or not. Enumeration: 'disabled': 2, 'enabled': 1.
             an80iEthernetFollowsWireless 1.3.6.1.4.1.10728.2.1.3.1.3.5 integer read-write
This object specifies if the Ethernet follows wireless mode is enabled or not. Enumeration: 'disabled': 2, 'enabled': 1.
             an80iEthernetFollowsWirelessTimeout 1.3.6.1.4.1.10728.2.1.3.1.3.6 integer read-write
This object specifies if the timeout (seconds) for the Ethernet follows wireless mode (0=infinite).
         redlineAn80iManagObjects 1.3.6.1.4.1.10728.2.1.3.1.4
             an80iHttpAccess 1.3.6.1.4.1.10728.2.1.3.1.4.1 integer read-write
This object specifies if Http Access is enabled or not. Enumeration: 'disabled': 2, 'enabled': 1.
             an80iTelnetAccess 1.3.6.1.4.1.10728.2.1.3.1.4.2 integer read-write
This object specifies if Telnet Access is enabled or not. Enumeration: 'disabled': 2, 'enabled': 1.
             an80iTelnetPort 1.3.6.1.4.1.10728.2.1.3.1.4.3 inetportnumber read-write
This object specifies the Telnet port number.
         redlineAn80iSWUpgradeObjects 1.3.6.1.4.1.10728.2.1.3.1.5
             an80iSwDownloadTftpAddressType 1.3.6.1.4.1.10728.2.1.3.1.5.1 inetaddresstype read-write
The INET address type of the software upgrade TFTP server. IPv4 type supported only.
             an80iSwDownloadTftpAddress 1.3.6.1.4.1.10728.2.1.3.1.5.2 inetaddress read-write
The INET address of the TFTP server.
             an80iSwDownloadTftpFile 1.3.6.1.4.1.10728.2.1.3.1.5.3 displaystring read-write
The image file name as required by the TFTP server.
             an80iSwDownloadStatus 1.3.6.1.4.1.10728.2.1.3.1.5.4 integer read-only
The status of the current software download. Enumeration: 'download': 1, 'failed': 4, 'inProgress': 2, 'success': 3.
             an80iSwDownloadControl 1.3.6.1.4.1.10728.2.1.3.1.5.5 integer read-write
Trigger software upgrade Enumeration: 'startUpgrade': 2, 'noop': 1.
     redlineAn80iPmpObjects 1.3.6.1.4.1.10728.2.1.3.2
         redlineAn80iPmpWirelesObjects 1.3.6.1.4.1.10728.2.1.3.2.1
             an80iRegistrationPeriod 1.3.6.1.4.1.10728.2.1.3.2.1.1 integer read-write
Number of frames between two consecutive registration periods.
             an80iMaximumDistance 1.3.6.1.4.1.10728.2.1.3.2.1.2 integer read-write
Maximum distance in km between the sector controller and one subscriber station.
             an80iRegisteredStations 1.3.6.1.4.1.10728.2.1.3.2.1.3 integer32 read-only
The number of registered stations on the sector controller.
             an80iRegisteredConnections 1.3.6.1.4.1.10728.2.1.3.2.1.4 integer32 read-only
The number of registered connections on the sector controller.
             an80iMaxId 1.3.6.1.4.1.10728.2.1.3.2.1.5 integer read-only
The maximum number of ID used to identify links, connections and groups
             an80iNextAvailId 1.3.6.1.4.1.10728.2.1.3.2.1.6 integer32 read-only
The next available ID from the ID pool which is not grater then that defined in 'an80iMaxId'
             an80iLastModifId 1.3.6.1.4.1.10728.2.1.3.2.1.7 integer32 read-only
The last modified ID from the ID pool which is not grater then that defined in 'an80iMaxId'
             an80iSaveIdConfiguration 1.3.6.1.4.1.10728.2.1.3.2.1.8 integer read-write
Save the ID table in the flash memory Enumeration: 'save': 2, 'noop': 1.
     redlineAn80iPtpObjects 1.3.6.1.4.1.10728.2.1.3.3
         redlineAn80iPtpSystemObjects 1.3.6.1.4.1.10728.2.1.3.3.1
             an80iResetStatistics 1.3.6.1.4.1.10728.2.1.3.3.1.1 integer read-write
This object resets wireless and Ethernet counters Enumeration: 'reset': 2, 'noop': 1.
     redlineAn80iConformance 1.3.6.1.4.1.10728.2.1.3.5
         redlineAn80iGroups 1.3.6.1.4.1.10728.2.1.3.5.1
             redlineAn80iPtpPmpGroup 1.3.6.1.4.1.10728.2.1.3.5.1.1
AN80i PTP/PMP objects.
             redlineAn80iPmpGroup 1.3.6.1.4.1.10728.2.1.3.5.1.2
AN80i PMP objects.
             redlineAn80iPtpGroup 1.3.6.1.4.1.10728.2.1.3.5.1.3
AN80i PTP objects.
             redlineAn80iNotificationGroup 1.3.6.1.4.1.10728.2.1.3.5.1.4
The notifications which indicate specific events within the AN80i unit.
         redlineAn80iCompls 1.3.6.1.4.1.10728.2.1.3.5.2
             redlineAn80iCompliance 1.3.6.1.4.1.10728.2.1.3.5.2.1
The compliance statement for AN80i entities that implement this MIB module.