Download standard MIB format if you are planning to load a MIB file into some system (OS, Zabbix, PRTG ...) or view it with a MIB browser. CSV is more suitable for analyzing and viewing OID' and other MIB objects in excel. JSON and YAML formats are usually used in programing even though some systems can use MIB in YAML format (like Logstash).
Keep in mind that standard MIB files can be successfully loaded by systems and programs only if all the required MIB's from the "Imports" section are already loaded.
The tree-like SNMP object navigator requires no explanations because it is very simple to use. And if you stumbled on this MIB from Google note that you can always go back to the home page if you need to perform another MIB or OID lookup.


Object Name OID Type Access Info
 netgear 1.3.6.1.4.1.4526
           ngNasManager 1.3.6.1.4.1.4526.22
                 nasMgrSoftwareVersion 1.3.6.1.4.1.4526.22.1 displaystring read-only
Version information for the ReadyDATAOS ngNasManager software.
                 diskTable 1.3.6.1.4.1.4526.22.3 no-access
A table of physical disks attached to the storage device.
                     diskEntry 1.3.6.1.4.1.4526.22.3.1 no-access
An entry in the physical disk table.
                         diskNumber 1.3.6.1.4.1.4526.22.3.1.1 integer read-only
Instance number of the disk entry.
                         diskID 1.3.6.1.4.1.4526.22.3.1.2 displaystring read-only
Disk ID.
                         diskSlotName 1.3.6.1.4.1.4526.22.3.1.3 displaystring read-only
The slot location of the disk.
                         diskSerial 1.3.6.1.4.1.4526.22.3.1.4 displaystring read-only
Disk Serial number.
                         diskModel 1.3.6.1.4.1.4526.22.3.1.5 displaystring read-only
The disk drive's model name.
                         ataError 1.3.6.1.4.1.4526.22.3.1.6 integer read-only
ATA error number for this disk from S.M.A.R.T read.
                         diskCapacity 1.3.6.1.4.1.4526.22.3.1.7 displaystring read-only
The capacity of the disk in bytes.
                         diskInterface 1.3.6.1.4.1.4526.22.3.1.8 displaystring read-only
The disk connect interface, such as SATA, USB etc.
                         diskState 1.3.6.1.4.1.4526.22.3.1.9 displaystring read-only
The current state of the Disk. Possible states: 0: Online 1: Offline
                         diskTemperature 1.3.6.1.4.1.4526.22.3.1.10 integer read-only
temperature of this disk(in Fahrenheit unit).
                 fanTable 1.3.6.1.4.1.4526.22.4 no-access
                     fanEntry 1.3.6.1.4.1.4526.22.4.1 no-access
                         fanNumber 1.3.6.1.4.1.4526.22.4.1.1 integer read-only
Instance number of this fan entry.
                         fanRPM 1.3.6.1.4.1.4526.22.4.1.2 integer read-only
The current speed of the fan.
                         fanStatus 1.3.6.1.4.1.4526.22.4.1.3 displaystring read-only
The status of Fan
                         fanType 1.3.6.1.4.1.4526.22.4.1.4 displaystring read-only
What fan is used for: SYS: for system board CPU: for CPU CASE: for system case
                 temperatureTable 1.3.6.1.4.1.4526.22.5 no-access
                     temperatureEntry 1.3.6.1.4.1.4526.22.5.1 no-access
                         temperatureNumber 1.3.6.1.4.1.4526.22.5.1.1 integer read-only
Instance number of this temperature probe entry.
                         temperatureValue 1.3.6.1.4.1.4526.22.5.1.2 integer read-only
The current temperature of this probe (in Fahrenheit unit).
                         temperatureTyoe 1.3.6.1.4.1.4526.22.5.1.3 displaystring read-only
The current temperature refer to
                         temperatureMin 1.3.6.1.4.1.4526.22.5.1.4 integer read-only
The min temperature of this probe (in Fahrenheit unit).
                         temperatureMax 1.3.6.1.4.1.4526.22.5.1.5 integer read-only
The max temperature of this probe (in Fahrenheit unit).
                 volumeTable 1.3.6.1.4.1.4526.22.7 no-access
A table of active volumes on the storage device.
                     volumeEntry 1.3.6.1.4.1.4526.22.7.1 no-access
An entry in the volume table.
                         volumeNumber 1.3.6.1.4.1.4526.22.7.1.1 integer read-only
Instance number of the volume entry.
                         volumeName 1.3.6.1.4.1.4526.22.7.1.2 displaystring read-only
The name of the volume.
                         volumeRAIDLevel 1.3.6.1.4.1.4526.22.7.1.3 displaystring read-only
The RAID level of the volume.
                         volumeStatus 1.3.6.1.4.1.4526.22.7.1.4 displaystring read-only
The severity of the volume. Possible values: 1: ONLINE 2: OFFLINE 3: DEGRADED 4: FAULTED 5: REMOVED 6: UNAVAILABLE 7: UNKNOWN
                         volumeSize 1.3.6.1.4.1.4526.22.7.1.5 integer read-only
The size of the volume in megabytes.
                         volumeFreeSpace 1.3.6.1.4.1.4526.22.7.1.6 integer read-only
Free space on the volume in megabytes.
                 psuTable 1.3.6.1.4.1.4526.22.8 no-access
                     psuEntry 1.3.6.1.4.1.4526.22.8.1 read-only
                         psuNumber 1.3.6.1.4.1.4526.22.8.1.1 integer read-only
Instance number of this power supply unit.
                         psuDesc 1.3.6.1.4.1.4526.22.8.1.2 displaystring read-only
The description of this PSU.
                         psuStatus 1.3.6.1.4.1.4526.22.8.1.3 displaystring read-only
The current PSU status.
                 aryMgrEvts 1.3.6.1.4.1.4526.22.200
                         controllerNameEv 1.3.6.1.4.1.4526.22.200.201 displaystring read-only
Controller Name for which trap is generated.
                         channelNumberEv 1.3.6.1.4.1.4526.22.200.202 integer read-only
Channel Number for which trap is generated.
                         targetIDEv 1.3.6.1.4.1.4526.22.200.203 integer read-only
SCSI ID of the device for which trap is generated.
                         virtualDiskNameEv 1.3.6.1.4.1.4526.22.200.204 displaystring read-only
Virtual Disk for which trap is generated.
                         arrayDiskNameEv 1.3.6.1.4.1.4526.22.200.205 displaystring read-only
Array Disk for which trap is generated.
                         oldVDConfigEv 1.3.6.1.4.1.4526.22.200.206 displaystring read-only
Current Virtual Disk configuration for which trap is generated
                         newVDConfigEv 1.3.6.1.4.1.4526.22.200.207 displaystring read-only
New Virtual Disk configuration for which trap is generated.
                         enclosureNumberEv 1.3.6.1.4.1.4526.22.200.208 integer read-only
Enclosure Number for which trap is generated.
                         unitNumberEv 1.3.6.1.4.1.4526.22.200.209 integer read-only
Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)
                         enclosureNameEv 1.3.6.1.4.1.4526.22.200.210 displaystring read-only
Enclosure Name for which trap is generated.
                         unitNameEv 1.3.6.1.4.1.4526.22.200.211 displaystring read-only
Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)
                         timeEv 1.3.6.1.4.1.4526.22.200.212 integer read-only
Amount of time specified in the trap message.
                         volumeNameEv 1.3.6.1.4.1.4526.22.200.213 displaystring read-only
Volume Drive Letter for which trap is generated.
                 nasTraps 1.3.6.1.4.1.4526.22.300
                 fanFailureMesg 1.3.6.1.4.1.4526.22.400 displaystring read-only
Failure message for Fan
                 tempFailureMesg 1.3.6.1.4.1.4526.22.401 displaystring read-only
Failure message for system temperature
                 powerVoltageMesg 1.3.6.1.4.1.4526.22.402 displaystring read-only
Failure message for system power
                 raidEventNoticeMesg 1.3.6.1.4.1.4526.22.403 displaystring read-only
RAID hotplug event message
                 snapshotEventNoticeMesg 1.3.6.1.4.1.4526.22.404 displaystring read-only
Snapshot messages
                 upsEventNoticeMesg 1.3.6.1.4.1.4526.22.405 displaystring read-only
UPS status message
                 hotplugDiskNoticeMesg 1.3.6.1.4.1.4526.22.406 displaystring read-only
Disk hotplug event messages
                 volumeNoticeMesg 1.3.6.1.4.1.4526.22.407 displaystring read-only
Disk usage warning
                 diskTempWarningMesg 1.3.6.1.4.1.4526.22.408 displaystring read-only
Disk temperature warning messages
                 backupNoticeMesg 1.3.6.1.4.1.4526.22.409 displaystring read-only
Backup job status messages
                 diskSmartWarningMesg 1.3.6.1.4.1.4526.22.410 displaystring read-only
Disk SMART messages
                 psuWarningMesg 1.3.6.1.4.1.4526.22.411 displaystring read-only
PSU status messages
                           fanFailure 1.3.6.1.4.1.4526.22.3000.10
Fan failure, fan speed is %s.
                           tempFailure 1.3.6.1.4.1.4526.22.3000.20
Temperature sensor reports out of normal range.
                           powerVoltage 1.3.6.1.4.1.4526.22.3000.30
System power is out of spec, please check system status!
                           raidEventNotice 1.3.6.1.4.1.4526.22.3000.40
RAID event detected!
                           snapshotEventNotice 1.3.6.1.4.1.4526.22.3000.50
Snapshot event detected!
                           hotplugDiskNotice 1.3.6.1.4.1.4526.22.3000.60
Hotplug disk event detected!
                           upsEventNotice 1.3.6.1.4.1.4526.22.3000.70
UPS status.
                           volumeNotice 1.3.6.1.4.1.4526.22.3000.80
Volume is approaching capacity.
                           diskTempWarning 1.3.6.1.4.1.4526.22.3000.90
Disk temperature warning.
                           backupNotice 1.3.6.1.4.1.4526.22.3000.100
Backup job status.
                           diskSmartWarning 1.3.6.1.4.1.4526.22.3000.110
Disk SMART warning.
                           psuWarning 1.3.6.1.4.1.4526.22.3000.120
Power supply unit warning.
           productID 1.3.6.1.4.1.4526.100